Note: The test data was only valid for the test sample(s). This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. Some of the tests or test methods in this report may not in NVLAP accreditation scope and was noted. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. IES LM-79-08 MEASUREMENT AND TEST REPORT For ShenzhenBrilloopLightingCo.,Lt 6F,B6Building,JunfengIndustrialPark,YongheRoad,Fuyong,BaoanDistrict,Shenzhen City,GuangdongProvince,P.R.Chin Test Model: BLP-HBL300WE06 Report Type: Electrical and Photometric tests including: Luminous Flux, Power Factor, Chromaticity, Luminous Intensity Distribution, THD Test Engineer: Bill Xiong Hill Liu Report Number: R2DG170711053-10 Test Date: 2017-07-13 to 2017-07-14 Report Date: 2017-07-17 Reviewed By: Daniel Duan /EE Manager Test Facility: Test facility was located at No.69, Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China. Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone, Shenzhen, Guangdong, China. Tel: +86-755-33320018 Fax: +86-755-33320008 Accreditation: The NVLAP Lab Code is 200707-0.

IES LM-79-08 TEST REPORT · The NVLAP Lab Code is 200707-0 Report No. Page R2DG170711053-10 3 of 15 Device Manufacture Model No Serial No Test Range Calibration date Calibration due

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: IES LM-79-08 TEST REPORT · The NVLAP Lab Code is 200707-0 Report No. Page R2DG170711053-10 3 of 15 Device Manufacture Model No Serial No Test Range Calibration date Calibration due

Note: The test data was only valid for the test sample(s). This test report is prepared for the customer shown above and for the

device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance

Laboratories Corp. (Shenzhen). This report must not be used by the customer to claim product certification, approval, or

endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. Some of the tests or test methods in this report

may not in NVLAP accreditation scope and was noted.

This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above

version 7.0.

IES LM-79-08 MEASUREMENT AND TEST REPORT

For

ShenzhenBrilloopLightingCo.,Lt 6F,B6Building,JunfengIndustrialPark,YongheRoad,Fuyong,Bao’anDistrict,Shenzhen

City,GuangdongProvince,P.R.Chin

Test Model: BLP-HBL300WE06

Report Type: Electrical and Photometric tests including: Luminous Flux,

Power Factor, Chromaticity, Luminous Intensity

Distribution, THD

Test Engineer: Bill Xiong Hill Liu

Report Number: R2DG170711053-10

Test Date: 2017-07-13 to 2017-07-14

Report Date: 2017-07-17

Reviewed By: Daniel Duan /EE Manager

Test Facility: Test facility was located at No.69, Pulongcun, Puxinhu Industry

Area, Tangxia, Dongguan, Guangdong, China.

Prepared By:

Bay Area Compliance Laboratories Corp. (Shenzhen)

6/F., West Wing, Third Phase of Wanli Industrial Building,

Shihua Road, Futian Free Trade Zone,

Shenzhen, Guangdong, China.

Tel: +86-755-33320018

Fax: +86-755-33320008

Accreditation: The NVLAP Lab Code is 200707-0.

Page 2: IES LM-79-08 TEST REPORT · The NVLAP Lab Code is 200707-0 Report No. Page R2DG170711053-10 3 of 15 Device Manufacture Model No Serial No Test Range Calibration date Calibration due

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711053-10 Page 2 of 15

1. Product Description

General Information:

One sample was received on 2017-07-11.

Model Tested: BLP-HBL300WE06

Manufacturer: ShenzhenBrilloopLightingCo.,Lt

Brand Name: Brilloop

Product Designation: LED High Bay Light

Burning Time Before Test: 0hour(For New Products)

Driver Model: HLG-320H-48A

Rated Values:

Rated Voltage/Frequency: 100-240 V AC 50/60Hz

Rated Power: 300 W

Nominal CCT: 4000K

Nominal Lumen Output: 45634Im

2. Standards Used

IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products

ANSI C82.77-2002: Harmonic Emission Limits – Related Power Quality Requirements for Lighting

IES TM-30-15: IES Method for Evaluating Light Source Color Rendition (This method is not in NVLAP

accreditation scope)

3. Description of Test Equipment

Device Manufacture Model No Serial No Test Range Calibration

date

Calibration due

date

1.5m temperature

integrating sphere SENSING SPR-600 S09008 25~50°C 2017-03-09 2018-03-09

High-precision

rapid spectral

analysis system

EVERFINE HAAS-2000 M112048CA136

1125 380-780nm 2017-07-07 2018-07-07

Digital power

meter YOKOGAWA WT310 13398 N/A 2016-12-05 2017-12-05

Programmable

Precision DC

Power Supply

ITECH IT6154 0061 0417 6471

0010 19 0~32V 2017-03-03 2018-03-03

thermometer SENSING NA NA 25、50°C 2017-03-09 2018-03-09

Standard Light

Source SENSING NA LSD090808 N/A 2016-12-05 2017-12-05

Precision

frequency power

supply

ALL Power APW-105N 970613 220V±10%

50Hz 2017-03-03 2018-03-03

AC POWER

SUPPLY EVERFINE VPS1030 PWM 1012017

0-150V, 0-

300V 2017-03-03 2018-03-03

Digital CC&CV

DC Power Supply EVERFINE WY12010 1009009 30V/5A 2017-03-03 2018-03-03

Digital power

meter YOKOGAWA WT-210 91KB35700

15/30/60/150/30

0/600 V 2017-03-03 2018-03-03

full-field speed

goniophotometer EVERFINE GO-R5000

YG108492N101

20001

1600mm,3000

W/10A 2017-03-09 2018-03-09

Page 3: IES LM-79-08 TEST REPORT · The NVLAP Lab Code is 200707-0 Report No. Page R2DG170711053-10 3 of 15 Device Manufacture Model No Serial No Test Range Calibration date Calibration due

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711053-10 Page 3 of 15

Device Manufacture Model No Serial No Test Range Calibration

date

Calibration due

date

Wireless Remote

Sensor N/A 433MHz N/A

0°C~50°C;-

20°C~60°C 2017-03-20 2018-03-20

Standard Light

Source EVERFINE D908 1012003 N/A 2016-12-17 2017-12-17

Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI).

4. Test Method

Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25°C±1°C during measurement. And relative humidity is less than 65%.

Integrating Sphere System

The system includes AC power source, digital power meter, DC power supply, Spectroradiometer, and integrating sphere. The integrating sphere system is calibrated by standard spectrum light source before measurement.

4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report.

The uncertainty of the light output (luminous flux) measurements is U=2.1% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=32K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=2.1 (K=2) , at the 95% confidence level.

The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level.

Goniophotometer System

The goniophotometer system is calibrated by standard light source before measurement.

Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report. The vertical angle (γ) test intervals were set no more than 1 degree while data for 5 degree intervals is reported. The horizontal angle (C plane) test intervals were set no more than 22.5 degree.

The uncertainty of the luminous intensity is U=1.6% (K=2) , at the 95% confidence level.

Additional Test

The Additional Test item may not be covered by IESNA LM-79-2008. Additional test is THD, was measured by Digital Power Meter after stabilized at 25°C±1°C.Test voltage for THD test would be equal to rated voltage or, in case of a voltage range, maximum value of that range.

The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level.

Fidelity Index and Gamut Index Calculation

The Rf, Rg was calculated according to IES TM-30-15 by using calculation tools. The calculation was based on the

measured SPD from 380nm to 780nm with 1nm intervals. All the colors in this report is for reference only.

Page 4: IES LM-79-08 TEST REPORT · The NVLAP Lab Code is 200707-0 Report No. Page R2DG170711053-10 3 of 15 Device Manufacture Model No Serial No Test Range Calibration date Calibration due

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711053-10 Page 4 of 15

5. Test Result

[Integrating Sphere System]

Total operating time for integrating sphere test: 1.0 hour

Test orientation: Downward

Photometric and Electrical Measurement Result

Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor Luminous Flux(lm)

Efficacy (lm/W)

229.9 50 1.329 301.2 0.9854 45634 151.51

Radiant Flux (W) CCT (K) Duv x y u' v'

139.00 4224 -0.000237 0.3709 0.3701 0.2215 0.4972

Color Rendering Index

Ra

82.2

R1 R2 R3 R4

81 88 93 82

R5 R6 R7 R8

81 82 86 65

R9 R10 R11 R12

7 70 80 58

R13 R14 R15

82 96 75

-20 0 20 40 60 80 100

Page 5: IES LM-79-08 TEST REPORT · The NVLAP Lab Code is 200707-0 Report No. Page R2DG170711053-10 3 of 15 Device Manufacture Model No Serial No Test Range Calibration date Calibration due

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711053-10 Page 5 of 15

Fidelity Index and Gamut Index

Fidelity Index Rf 81

Gamut Index Rg 96

Spectral Power Distribution Comparison

Plot of Rg versus Rf

0

0.2

0.4

0.6

0.8

1

1.2

1.4

1.6

1.8

380 430 480 530 580 630 680 730 780

SPD

(n

orm

aliz

ed

to

Y=1

00

)

l (nm)

Test source Reference source

60

70

80

90

100

110

120

130

140

50 60 70 80 90 100

Rg

Rf

Page 6: IES LM-79-08 TEST REPORT · The NVLAP Lab Code is 200707-0 Report No. Page R2DG170711053-10 3 of 15 Device Manufacture Model No Serial No Test Range Calibration date Calibration due

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711053-10 Page 6 of 15

Chroma Shift by Hue Rf by Hue

Color Vector Graphic

-20%

-15%

-10%

-5%

0%

5%

10%

15%

20%

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Hue Bin

50

55

60

65

70

75

80

85

90

95

100

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Hue Bin

Refenerce Illuminat Test Source

Page 7: IES LM-79-08 TEST REPORT · The NVLAP Lab Code is 200707-0 Report No. Page R2DG170711053-10 3 of 15 Device Manufacture Model No Serial No Test Range Calibration date Calibration due

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711053-10 Page 7 of 15

Color Fidelity by CES Sample

0 20 40 60 80 100

CES01

CES03

CES05

CES07

CES09

CES11

CES13

CES15

CES17

CES19

CES21

CES23

CES25

CES27

CES29

CES31

CES33

CES35

CES37

CES39

CES41

CES43

CES45

CES47

CES49

CES51

CES53

CES55

CES57

CES59

CES61

CES63

CES65

CES67

CES69

CES71

CES73

CES75

CES77

CES79

CES81

CES83

CES85

CES87

CES89

CES91

CES93

CES95

CES97

CES99

Fidelity Index, Rf

Co

lor

Eval

uat

ion

Sam

ple

Page 8: IES LM-79-08 TEST REPORT · The NVLAP Lab Code is 200707-0 Report No. Page R2DG170711053-10 3 of 15 Device Manufacture Model No Serial No Test Range Calibration date Calibration due

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711053-10 Page 8 of 15

Relative Spectral Power Distribution

nm mW nm mW nm mW nm mW nm mW

380 1.362E+01 421 5.073E+01 462 4.886E+02 503 3.962E+02 544 6.294E+02

381 1.230E+01 422 5.680E+01 463 4.698E+02 504 4.065E+02 545 6.318E+02

382 1.041E+01 423 6.332E+01 464 4.528E+02 505 4.182E+02 546 6.352E+02

383 9.613E+00 424 7.091E+01 465 4.325E+02 506 4.286E+02 547 6.394E+02

384 8.451E+00 425 7.882E+01 466 4.119E+02 507 4.395E+02 548 6.422E+02

385 9.610E+00 426 8.809E+01 467 3.884E+02 508 4.489E+02 549 6.459E+02

386 8.335E+00 427 9.888E+01 468 3.665E+02 509 4.582E+02 550 6.488E+02

387 7.332E+00 428 1.112E+02 469 3.427E+02 510 4.670E+02 551 6.517E+02

388 6.829E+00 429 1.233E+02 470 3.185E+02 511 4.776E+02 552 6.569E+02

389 6.993E+00 430 1.390E+02 471 2.959E+02 512 4.856E+02 553 6.588E+02

390 6.520E+00 431 1.548E+02 472 2.763E+02 513 4.941E+02 554 6.624E+02

391 6.733E+00 432 1.733E+02 473 2.590E+02 514 5.024E+02 555 6.658E+02

392 6.520E+00 433 1.943E+02 474 2.455E+02 515 5.094E+02 556 6.701E+02

393 6.092E+00 434 2.169E+02 475 2.344E+02 516 5.165E+02 557 6.741E+02

394 5.967E+00 435 2.415E+02 476 2.260E+02 517 5.237E+02 558 6.782E+02

395 5.898E+00 436 2.704E+02 477 2.216E+02 518 5.300E+02 559 6.807E+02

396 6.413E+00 437 3.040E+02 478 2.186E+02 519 5.360E+02 560 6.852E+02

397 6.369E+00 438 3.408E+02 479 2.178E+02 520 5.414E+02 561 6.892E+02

398 6.694E+00 439 3.834E+02 480 2.167E+02 521 5.464E+02 562 6.930E+02

399 7.082E+00 440 4.321E+02 481 2.184E+02 522 5.523E+02 563 6.967E+02

400 7.339E+00 441 4.879E+02 482 2.192E+02 523 5.566E+02 564 7.006E+02

401 7.871E+00 442 5.513E+02 483 2.208E+02 524 5.622E+02 565 7.050E+02

402 7.640E+00 443 6.191E+02 484 2.234E+02 525 5.669E+02 566 7.081E+02

403 8.010E+00 444 6.971E+02 485 2.255E+02 526 5.708E+02 567 7.119E+02

404 8.568E+00 445 7.777E+02 486 2.290E+02 527 5.736E+02 568 7.153E+02

405 9.139E+00 446 8.537E+02 487 2.332E+02 528 5.779E+02 569 7.190E+02

406 1.016E+01 447 9.268E+02 488 2.374E+02 529 5.822E+02 570 7.238E+02

407 1.130E+01 448 9.894E+02 489 2.444E+02 530 5.854E+02 571 7.272E+02

408 1.204E+01 449 1.031E+03 490 2.519E+02 531 5.877E+02 572 7.307E+02

409 1.372E+01 450 1.047E+03 491 2.587E+02 532 5.918E+02 573 7.343E+02

410 1.502E+01 451 1.040E+03 492 2.689E+02 533 5.952E+02 574 7.369E+02

411 1.653E+01 452 1.007E+03 493 2.798E+02 534 5.991E+02 575 7.398E+02

412 1.827E+01 453 9.553E+02 494 2.898E+02 535 6.013E+02 576 7.429E+02

413 2.050E+01 454 8.878E+02 495 3.010E+02 536 6.037E+02 577 7.465E+02

414 2.331E+01 455 8.163E+02 496 3.126E+02 537 6.071E+02 578 7.494E+02

415 2.544E+01 456 7.429E+02 497 3.245E+02 538 6.111E+02 579 7.531E+02

416 2.888E+01 457 6.753E+02 498 3.373E+02 539 6.126E+02 580 7.546E+02

417 3.265E+01 458 6.189E+02 499 3.488E+02 540 6.163E+02 581 7.578E+02

418 3.680E+01 459 5.749E+02 500 3.613E+02 541 6.194E+02 582 7.592E+02

419 4.073E+01 460 5.381E+02 501 3.731E+02 542 6.230E+02 583 7.616E+02

420 4.578E+01 461 5.101E+02 502 3.859E+02 543 6.253E+02 584 7.642E+02

0.0

0.2

0.4

0.6

0.8

1.0

380 430 480 530 580 630 680 730 780

Page 9: IES LM-79-08 TEST REPORT · The NVLAP Lab Code is 200707-0 Report No. Page R2DG170711053-10 3 of 15 Device Manufacture Model No Serial No Test Range Calibration date Calibration due

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711053-10 Page 9 of 15

nm mW nm mW nm mW nm mW nm mW

585 7.648E+02 626 6.061E+02 667 2.488E+02 708 7.450E+01 749 2.085E+01

586 7.664E+02 627 5.960E+02 668 2.423E+02 709 7.195E+01 750 2.046E+01

587 7.696E+02 628 5.891E+02 669 2.359E+02 710 7.061E+01 751 1.999E+01

588 7.708E+02 629 5.798E+02 670 2.294E+02 711 6.750E+01 752 1.930E+01

589 7.700E+02 630 5.700E+02 671 2.229E+02 712 6.518E+01 753 1.861E+01

590 7.717E+02 631 5.610E+02 672 2.165E+02 713 6.357E+01 754 1.831E+01

591 7.728E+02 632 5.517E+02 673 2.114E+02 714 6.211E+01 755 1.792E+01

592 7.726E+02 633 5.427E+02 674 2.057E+02 715 5.998E+01 756 1.714E+01

593 7.729E+02 634 5.324E+02 675 1.999E+02 716 5.831E+01 757 1.649E+01

594 7.723E+02 635 5.236E+02 676 1.938E+02 717 5.624E+01 758 1.619E+01

595 7.721E+02 636 5.137E+02 677 1.887E+02 718 5.449E+01 759 1.616E+01

596 7.701E+02 637 5.037E+02 678 1.832E+02 719 5.305E+01 760 1.554E+01

597 7.689E+02 638 4.949E+02 679 1.784E+02 720 5.101E+01 761 1.503E+01

598 7.676E+02 639 4.850E+02 680 1.734E+02 721 5.004E+01 762 1.452E+01

599 7.648E+02 640 4.760E+02 681 1.686E+02 722 4.853E+01 763 1.392E+01

600 7.625E+02 641 4.656E+02 682 1.635E+02 723 4.675E+01 764 1.390E+01

601 7.591E+02 642 4.567E+02 683 1.585E+02 724 4.525E+01 765 1.324E+01

602 7.572E+02 643 4.472E+02 684 1.541E+02 725 4.395E+01 766 1.308E+01

603 7.538E+02 644 4.369E+02 685 1.500E+02 726 4.227E+01 767 1.271E+01

604 7.505E+02 645 4.281E+02 686 1.456E+02 727 4.102E+01 768 1.216E+01

605 7.467E+02 646 4.187E+02 687 1.413E+02 728 3.988E+01 769 1.167E+01

606 7.433E+02 647 4.093E+02 688 1.370E+02 729 3.903E+01 770 1.139E+01

607 7.385E+02 648 4.009E+02 689 1.329E+02 730 3.760E+01 771 1.149E+01

608 7.331E+02 649 3.919E+02 690 1.292E+02 731 3.643E+01 772 1.088E+01

609 7.296E+02 650 3.836E+02 691 1.251E+02 732 3.561E+01 773 1.048E+01

610 7.236E+02 651 3.740E+02 692 1.211E+02 733 3.460E+01 774 1.023E+01

611 7.178E+02 652 3.659E+02 693 1.174E+02 734 3.304E+01 775 1.026E+01

612 7.119E+02 653 3.565E+02 694 1.147E+02 735 3.246E+01 776 1.009E+01

613 7.066E+02 654 3.486E+02 695 1.107E+02 736 3.112E+01 777 9.450E+00

614 6.996E+02 655 3.402E+02 696 1.083E+02 737 2.991E+01 778 9.439E+00

615 6.926E+02 656 3.312E+02 697 1.038E+02 738 2.952E+01 779 9.457E+00

616 6.857E+02 657 3.230E+02 698 1.008E+02 739 2.837E+01 780 9.475E+00

617 6.781E+02 658 3.153E+02 699 9.852E+01 740 2.755E+01

618 6.713E+02 659 3.078E+02 700 9.515E+01 741 2.668E+01

619 6.636E+02 660 3.000E+02 701 9.205E+01 742 2.636E+01

620 6.560E+02 661 2.923E+02 702 8.980E+01 743 2.521E+01

621 6.491E+02 662 2.849E+02 703 8.676E+01 744 2.429E+01

622 6.394E+02 663 2.778E+02 704 8.439E+01 745 2.376E+01

623 6.319E+02 664 2.701E+02 705 8.124E+01 746 2.300E+01

624 6.229E+02 665 2.626E+02 706 7.900E+01 747 2.221E+01

625 6.145E+02 666 2.569E+02 707 7.649E+01 748 2.160E+01

Page 10: IES LM-79-08 TEST REPORT · The NVLAP Lab Code is 200707-0 Report No. Page R2DG170711053-10 3 of 15 Device Manufacture Model No Serial No Test Range Calibration date Calibration due

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711053-10 Page 10 of 15

CIE 1931 x y Chromaticity Diagram

7-Step Chromaticity Quadrangles

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

0.30

0.35

0.40

0.45

0.30 0.35 0.40 0.45 0.50 0.55

sample

7-STEP 2200K

7-STEP 2500K

7-STEP 2700K

7-STEP 3000K

7-STEP 3500K

7-STEP 4000K

7-STEP 4500K

7-STEP 5000K

7-STEP 5700K

7-STEP 6500K

Page 11: IES LM-79-08 TEST REPORT · The NVLAP Lab Code is 200707-0 Report No. Page R2DG170711053-10 3 of 15 Device Manufacture Model No Serial No Test Range Calibration date Calibration due

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711053-10 Page 11 of 15

[Goniophotometer System]

Total operating time for luminous intensity distribution: 1.0 hour

Test orientation: Downward

Electrical Measurement

Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor

230.1 50 1.327 300.8 0.9852

Photometric Measurement

Luminous Flux (lm) Efficacy (lm/W) Imax (cd) S/MH (C0/180) S/MH (C90/270)

45666.6 151.80 16528 1.30 1.30

Luminous Intensity Distribution

C0/180 C45/225 C90/270 C135/315 AVG.

Beam Angle (50% Imax): 115.7 116.0 116.2 115.8 115.9

Field Angle (10% Imax): 149.6 149.6 149.7 149.5 149.6

Page 12: IES LM-79-08 TEST REPORT · The NVLAP Lab Code is 200707-0 Report No. Page R2DG170711053-10 3 of 15 Device Manufacture Model No Serial No Test Range Calibration date Calibration due

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711053-10 Page 12 of 15

Luminous Intensity (cd) Distribution Data

C

0° 22.5° 45° 67.5° 90° 112.5° 135° 157.5° γ

0.0° 16524 16524 16524 16524 16524 16524 16524 16524

5.0° 16480 16478 16482 16486 16492 16492 16494 16496

10.0° 16334 16338 16351 16359 16367 16373 16375 16377

15.0° 16088 16111 16130 16152 16152 16164 16163 16157

20.0° 15723 15778 15841 15873 15877 15873 15862 15834

25.0° 15160 15222 15318 15380 15395 15377 15340 15327

30.0° 14346 14399 14472 14509 14526 14539 14524 14522

35.0° 13257 13296 13319 13321 13354 13428 13466 13466

40.0° 12047 12043 11993 11903 11967 12139 12238 12236

45.0° 10999 10968 10888 10855 10898 11052 11138 11136

50.0° 10042 10043 10036 10063 10090 10181 10222 10196

55.0° 8902 8943 9006 9085 9112 9124 9124 9097

60.0° 7385 7441 7530 7621 7644 7634 7632 7611

65.0° 5490 5595 5573 5648 5673 5689 5714 5728

70.0° 3406 3477 3529 3566 3594 3635 3665 3677

75.0° 1392 1444 1495 1532 1557 1573 1589 1600

80.0° 185 244 260 278 292 296 303 311

85.0° 10 9 9 8 9 9 9 10

90.0° 2 2 2 2 2 2 2 2

95.0° 3 3 3 3 3 3 3 3

100.0° 4 4 4 4 4 4 4 4

105.0° 5 5 5 5 5 5 5 5

110.0° 5 5 5 5 5 5 5 5

115.0° 5 5 5 5 5 5 5 5

120.0° 6 5 5 6 6 5 5 5

125.0° 6 6 6 6 6 6 6 6

130.0° 8 8 7 8 8 7 7 7

135.0° 9 9 9 9 10 9 9 9

140.0° 11 11 12 12 12 12 12 11

145.0° 14 14 15 15 16 16 15 14

150.0° 17 18 18 18 19 19 18 17

155.0° 19 20 20 20 21 21 21 20

160.0° 21 22 21 22 22 23 23 22

165.0° 22 22 21 22 22 22 22 22

170.0° 20 20 20 20 20 20 21 21

175.0° 20 20 19 19 18 19 20 20

180.0° 18 17 18 18 18 18 19 19

Page 13: IES LM-79-08 TEST REPORT · The NVLAP Lab Code is 200707-0 Report No. Page R2DG170711053-10 3 of 15 Device Manufacture Model No Serial No Test Range Calibration date Calibration due

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711053-10 Page 13 of 15

Luminous Intensity (cd) Distribution Data (cont.)

C

180° 202.5° 225° 247.5° 270° 292.5° 315° 337.5° γ

0.0° 16524 16524 16524 16524 16524 16524 16524 16524

5.0° 16495 16495 16494 16490 16488 16489 16486 16477

10.0° 16370 16373 16372 16367 16363 16353 16349 16333

15.0° 16145 16168 16171 16168 16150 16142 16113 16093

20.0° 15822 15862 15881 15883 15845 15797 15738 15735

25.0° 15368 15391 15409 15415 15360 15276 15212 15188

30.0° 14598 14621 14629 14619 14580 14519 14445 14403

35.0° 13528 13526 13506 13448 13421 13414 13381 13341

40.0° 12308 12303 12232 12083 12069 12174 12206 12189

45.0° 11195 11164 11058 10963 10968 11070 11127 11120

50.0° 10258 10265 10194 10159 10124 10157 10170 10152

55.0° 9193 9203 9187 9166 9107 9063 9044 9010

60.0° 7746 7734 7703 7692 7619 7550 7527 7514

65.0° 5891 5859 5808 5797 5724 5680 5661 5655

70.0° 3860 3804 3758 3702 3619 3574 3559 3564

75.0° 1762 1741 1693 1648 1633 1595 1564 1559

80.0° 365 365 333 351 338 329 310 303

85.0° 13 14 14 13 12 11 11 11

90.0° 1 1 1 1 1 1 1 1

95.0° 1 1 1 1 1 1 1 1

100.0° 2 2 2 2 2 2 2 2

105.0° 2 2 2 2 2 2 2 2

110.0° 3 3 3 3 3 3 3 3

115.0° 4 4 4 4 4 4 4 4

120.0° 4 4 4 5 5 5 4 5

125.0° 6 5 5 5 6 5 5 6

130.0° 7 6 6 6 6 6 6 6

135.0° 8 8 8 8 8 8 7 8

140.0° 9 9 9 9 9 9 9 9

145.0° 10 10 10 10 10 10 10 10

150.0° 11 11 11 11 11 11 11 11

155.0° 12 11 12 12 13 12 12 13

160.0° 13 13 13 13 13 13 13 14

165.0° 13 13 13 14 14 13 13 14

170.0° 14 14 13 14 14 13 13 14

175.0° 15 15 15 14 14 14 15 15

180.0° 18 18 17 17 16 16 17 18

Page 14: IES LM-79-08 TEST REPORT · The NVLAP Lab Code is 200707-0 Report No. Page R2DG170711053-10 3 of 15 Device Manufacture Model No Serial No Test Range Calibration date Calibration due

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711053-10 Page 14 of 15

Zonal Lumen Density Measurement

Deg Flux (lm) %

Deg Flux (lm) %

0-5 394.7 0.86 0-5 394.7 0.86

5-10 1175.1 2.58 0-10 1569.8 3.44

10-15 1927.9 4.22 0-15 3497.7 7.66

15-20 2635.2 5.77 0-20 6132.9 13.43

20-25 3269.2 7.16 0-25 9402.1 20.59

25-30 3779.7 8.28 0-30 13181.8 28.87

30-35 4114.2 9.00 0-35 17296.0 37.87

35-40 4257.1 9.33 0-40 21553.1 47.20

40-45 4276.4 9.36 0-45 25829.5 56.56

45-50 4277.8 9.37 0-50 30107.3 65.93

50-55 4190.6 9.17 0-55 34297.9 75.10

55-60 3870.4 8.48 0-60 38168.3 83.58

60-65 3239.2 7.09 0-65 41407.6 90.67

65-70 2366.7 5.19 0-70 43774.3 95.86

70-75 1340.3 2.93 0-75 45114.6 98.79

75-80 462.2 1.01 0-80 45576.8 99.80

80-85 43.5 0.10 0-85 45620.2 99.90

85-90 2.5 0.00 0-90 45622.7 99.90

90-95 0.9 0.01 0-95 45623.6 99.91

95-100 1.3 0.00 0-100 45625.0 99.91

100-105 1.7 0.00 0-105 45626.7 99.91

105-110 2.0 0.01 0-110 45628.7 99.92

110-115 2.1 0.00 0-115 45630.8 99.92

115-120 2.3 0.01 0-120 45633.1 99.93

120-125 2.5 0.00 0-125 45635.6 99.93

125-130 2.8 0.01 0-130 45638.4 99.94

130-135 3.1 0.00 0-135 45641.4 99.94

135-140 3.4 0.01 0-140 45644.9 99.95

140-145 3.8 0.01 0-145 45648.7 99.96

145-150 4.0 0.01 0-150 45652.7 99.97

150-155 3.9 0.01 0-155 45656.5 99.98

155-160 3.5 0.01 0-160 45660.1 99.99

160-165 2.9 0.00 0-165 45663.0 99.99

165-170 2.1 0.01 0-170 45665.0 100.00

170-175 1.2 0.00 0-175 45666.2 100.00

175-180 0.4 0.00 0-180 45666.6 100.00

Page 15: IES LM-79-08 TEST REPORT · The NVLAP Lab Code is 200707-0 Report No. Page R2DG170711053-10 3 of 15 Device Manufacture Model No Serial No Test Range Calibration date Calibration due

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711053-10 Page 15 of 15

[Additional Test]

Test Item Test Voltage (V) Frequency (Hz) Test Result

Total Harmonic Distortion: 230.0 50 3.55%

6. Product Photo

***********END OF REPORT***********