26
I.H & I.I MONTGOMERY COUNTY HISTORIC PRESERVATION COMMISSION STAFF REPORT Address: 23 West Irving Street, Chevy Chase Meeting Date: 7/29/2020 16 Magnolia Parkway, Chevy Chase Resource: Contributing Resources Report Date: 7/22/2020 Chevy Chase Village Historic District Applicant: Mike Friedman Public Notice: 7/15/2020 (Clinton & Associates, Landscape Architect) Review: HAWP Tax Credit: N/A Case Number: 35/13-20X Staff: Dan Bruecherrt 35/13-20Y PROPOSAL: STAFF RECOMMENDATION: Staff recommends that the HPC approve the HAWP applications. ARCHITECTURAL DESCRIPTION: SIGNIFICANCE: Contributing Resources within the Chevy Chase Village Historic District STYLE: Colonial Revival DATE: 1911 & 1914 Fig. 1: 23 West Irving (left) and 16 Magnolia Parkway have been the subject of previous HPC review. 1

I.H & I.I MONTGOMERY COUNTY HISTORIC PRESERVATION ... › wp-content › uploads › ...West Irving and to replace the slate walkway at 23 West Irving with matching stone paving. Staff

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

  • I.H & I.I

    MONTGOMERY COUNTY HISTORIC PRESERVATION COMMISSION

    STAFF REPORT

    Address: 23 West Irving Street, Chevy Chase Meeting Date: 7/29/2020

    16 Magnolia Parkway, Chevy Chase

    Resource: Contributing Resources Report Date: 7/22/2020

    Chevy Chase Village Historic District

    Applicant: Mike Friedman Public Notice: 7/15/2020

    (Clinton & Associates, Landscape Architect)

    Review: HAWP Tax Credit: N/A

    Case Number: 35/13-20X Staff: Dan Bruecherrt

    35/13-20Y

    PROPOSAL:

    STAFF RECOMMENDATION:

    Staff recommends that the HPC approve the HAWP applications.

    ARCHITECTURAL DESCRIPTION:

    SIGNIFICANCE: Contributing Resources within the Chevy Chase Village Historic District

    STYLE: Colonial Revival

    DATE: 1911 & 1914

    Fig. 1: 23 West Irving (left) and 16 Magnolia Parkway have been the subject of previous HPC review.

    1

  • I.H & I.I

    BACKGROUND

    On December 18, 2019, the HPC heard a preliminary consultation for work to the house at 23 West Irving

    St.1 The proposal focused on architectural alterations to the house and only talked conceptually about

    changes to the landscape/hardscape.

    The HAWP for this work at 23 West Irving was approved at the June 24, 2020 HPC meeting.2

    Both properties have the same owner who wishes to pursue one landscape and hardscape scheme. The

    properties have separate tax IDs and addresses and so must be heard with two separate HAWP case

    numbers.

    PROPOSAL

    The landscape/hardscape work proposed for the two properties will unify the design and visually connect

    the two Contributing Resources.

    The applicant proposes to undertake the following work at 16 Magnolia Pkwy.:

    • Remove the existing stone terraces;

    • Construct new natural stone terraces and walkways;

    • Expand the parking court;

    • Install a stone retaining wall; and

    • Remove a total of six (6) trees. At 23 West Irving St. , the applicant proposes to:

    • Remove the existing rear terrace;

    • Construct a new natural stone terrace;

    • Replace the existing walkway;

    • Construct a retaining wall along the sidewalk;

    • Remove and replace the existing fencing; and

    • Remove a total of eleven (11) trees.

    APPLICABLE GUIDELINES:

    When reviewing alterations and new construction within the Chevy Chase Village Historic District

    several documents are to be utilized as guidelines to assist the Commission in developing their decision.

    These documents include the historic preservation review guidelines in the approved and adopted

    amendment for the Chevy Chase Village Historic District (Guidelines), Montgomery County Code

    Chapter 24A (Chapter 24A), and the Secretary of the Interior’s Standards for Rehabilitation (Standards).

    The pertinent information in these documents is outlined below.

    The Guidelines break down specific projects into three levels of review – Lenient, Moderate and Strict

    Scrutiny.

    “Lenient Scrutiny” means that the emphasis of the review should be on issues of general

    massing and scale, and compatibility with the surrounding streetscape, and should allow for a very liberal

    interpretation of preservation rules. Most changes should be permitted unless there are major problems

    1 The Staff Report for the December 28, 2019 Preliminary Consultation can be found here:

    https://montgomeryplanning.org/wp-content/uploads/2019/12/II.A-23-West-Irving-Street-Chevy-Chase.pdf. 2 The Staff Report of the approved HAWP for 23 West Irving from June 24, 2020 can be found here:

    https://montgomeryplanning.org/wp-content/uploads/2020/06/I.W-23-West-Irving-Street-Chevy-Chase.pdf.

    2

    https://montgomeryplanning.org/wp-content/uploads/2019/12/II.A-23-West-Irving-Street-Chevy-Chase.pdfhttps://montgomeryplanning.org/wp-content/uploads/2020/06/I.W-23-West-Irving-Street-Chevy-Chase.pdf

  • I.H & I.I

    with massing, scale and compatibility.

    “Moderate Scrutiny” involves a higher standard of review than “lenient scrutiny.” Besides

    issues of massing, scale and compatibility, preserving the integrity of the resource is taken into account.

    Alterations should be designed so that the altered structure still contributes to the district. Use of

    compatible new materials, rather than the original building materials, should be permitted. Planned

    changes should be compatible with the structure’s existing design, but should not be required to replicate

    its architectural style.

    “Strict Scrutiny” means that the planned changes should be reviewed to insure that the intergrity

    of the significant exterior architectural or landscaping features and details is not compromised. However,

    strict scrutiny should not be “strict in theory but fatal in fact” i.e. it does not mean that there can be no

    changes but simply that the proposed changes should be reviewed with extra care.

    The Guidelines state three basic policies that should be adhered to, including:

    Preserving the integrity of the contributing structures in the district. Alterations to contributing structures

    should be designed in such a way that the altered structure still contributes to the district.

    Design review emphasis should be restricted to changes that will be visible from the front or side public

    right-of-way, or that would be visible in the absence of vegetation or landscaping.

    Alterations to the portion of a property that are not visible from the public right-of-way should be subject

    to very lenient review. Most changes to rear of the properties should be approved as a matter of course.

    The Guidelines that pertain to this project are as follows:

    o Fences should be subject to moderate scrutiny if they are visible from the public right-of-way, lenient scrutiny if they are not.

    o Lot coverage should be subject to strict scrutiny, in view of the critical importance of preserving the Village’s open park-like character.

    o Tree removal should be subject to strict scrutiny and consistent with the Chevy Chase Village Urban Forest Ordinance.

    Additional basic policies that should be adhered to include:

    1. Preserving the integrity of the proposed Chevy Chase Village Historic District. Any alterations should, at a minimum, perpetuate the ability to perceive the sense of time and place portrayed by

    the district.

    2. Preserving the integrity of contributing structures in the district. Alterations to contributing structures should be designed in such a way that the altered structure still contributes to the

    district.

    3. Maintaining the variety of architectural styles and the tradition of architectural excellence. 4. Design review emphasis should be restricted to changes that will be visible from the front or side

    public right-of-way, or that would be visible in the absence of vegetation or landscaping.

    5. Alterations to the portion of a property that are not visible from the public right-of-way should be subject to a very lenient review. Most changes to the rear of the properties should be approved as

    a matter of course.

    Montgomery County Code; Chapter 24A-8

    3

  • I.H & I.I

    (a) The commission shall instruct the director to deny a permit if it finds, based on the evidence and information presented to or before the commission that the alteration for which the permit is

    sought would be inappropriate, inconsistent with or detrimental to the preservation, enhancement

    or ultimate protection of the historic site or historic resource within an historic district, and to the

    purposes of this chapter.

    (b) The commission shall instruct the director to issue a permit, or issue a permit subject to such conditions as are found to be necessary to insure conformity with the purposes and requirements

    of this chapter, if it finds that:

    (1) The proposal will not substantially alter the exterior features of an historic site or historic resource within an historic district; or

    (2) The proposal is compatible in character and nature with the historical, archeological, architectural or cultural features of the historic site or the historic district in which an historic

    resource is located and would not be detrimental thereto or to the achievement of the

    purposes of this chapter; or

    (c) It is not the intent of this chapter to limit new construction, alteration or repairs to any 1 period or architectural style.

    (d) In the case of an application for work on an historic resource located within an historic district, the commission shall be lenient in its judgment of plans for structures of little historical or design

    significance or for plans involving new construction, unless such plans would seriously impair the

    historic or architectural value of surrounding historic resources or would impair the character of

    the historic district. (Ord. No. 9-4, § 1; Ord. No. 11-59.)

    Secretary of the Interior’s Standards for Rehabilitation:

    #2: The historic character of a property will be retained and preserved. The removal of distinctive

    materials or alteration of features, spaces, and spatial relationships that characterize a property will be

    avoided.

    #9: New additions, exterior alterations, or related new construction will not destroy historic materials,

    features, and spatial relationships that characterize the property. The new work shall be differentiated

    from the old and will be compatible with the historic materials, features, size, scale and proportion, and

    massing to protect the integrity of the property and its environment.

    #10: New additions and adjacent or related new construction will be undertaken in such a manner that, if

    removed in the future, the essential form and integrity of the historic property and its environment would

    be unimpaired.

    STAFF DISCUSSION:

    For the two properties, the applicant proposes to remove several trees, remove and construct new terraces,

    expand hardscaping, construct a retaining wall, and install new fencing. Staff finds that the proposed

    work is compatible with the historic resources and surrounding district and recommends the approval of

    the two HAWPs.

    Tree Removal

    At 23 West Irving, the applicant proposes to remove a total of 11 trees. There are 6 Leyland Cypress,

    four Gum trees, and an Ash. Most of these trees are at the side or the rear of the property and the largest

    4

  • I.H & I.I

    is only 10” (ten inches) d.b.h. At 16 Magnolia, the applicant proposes to remove a total of 6 trees: a

    Maple, two cherry trees, and three Magnolias, the largest of which is 13” (thirteen inches) d.b.h.

    In place of these 17 trees, the applicant proposes to plant at least 25 additional deciduous trees and several

    additional evergreen trees.

    Staff finds that none of the trees proposed for removal are significant, but they do add to the park-like

    setting identified as a character-defining feature of the surrounding district. Staff finds that the most

    significant trees on the properties will be maintained. Staff additionally finds that the proposed planting

    will result in a net gain of both deciduous and evergreen trees on the site, introducing new trees that will

    grow and preserve the district’s character. Staff recommends the HPC approve the tree removal and re-

    planting.

    Terrace Construction

    The house at 23 West Irving has a slate patio in the rear of the house that projects slightly to the west and

    a slate walkway along the eastern side of the house. 16 Magnolia has a large slate patio to the east of the

    house an another off of the southwest corner of the house.

    The applicant proposes to remove all of the slate patios. These features are not historic, so their removal

    will not have an impact on the historic character of the houses or surrounding district and should be

    approved.

    The applicant proposes to pave a large area to the west of 16 Magnolia to the property boundary with 23

    West Irving and to replace the slate walkway at 23 West Irving with matching stone paving. Staff finds

    that while the amount of natural stone paving at 16 Magnolia is significant and will increase the paved lot

    coverage, it appears to Staff that the total paving at the two properties will be reduced by the proposal.

    The Design Guidelines require lot coverage to be reviewed under Strict Scrutiny to preserve the open

    park-like setting of the District.

    Because the grade slopes up from the street, the area of paving proposed at 16 Magnolia will not be

    visible from the right-of-way and should be approved as a matter of course, per the Design Guidelines.

    Additionally, Staff finds that the additional landscaping proposed will reinforce the park-like setting

    character of the surrounding district and recommends approval of the new terrace.

    Expanded Hardscaping

    The applicant proposes expanding the existing concrete parking court at 16 Magnolia. The existing

    parking court is accessed via a one-lane driveway off of Magnolia Ave., flanked by several trees. The

    applicant proposes expanding the parking court an additional 13’ 6” (thirteen feet, six inches) westward,

    toward the existing garage. Staff finds that this additional textured concrete will not have a substantial

    impact on the character of the lot and is setback a significant distance from the right-of-way. Staff finds

    the proposal is compatible with the character of the property and recommends the HPC approve the

    expansion of the hardscape under 24A-8(b)(2) and the Design Guidelines.

    Retaining Wall Construction

    The front yard at 23 West Irving is all grass. The grade rises sharply from the sidewalk. The applicant

    proposes to construct a retaining wall, with a maximum height of 3’ (three feet), setback from the

    sidewalk by approximately 3’ (three feet). The materials and appearance of the proposed retaining wall at

    23 West Irving will match the materials and construction to match the existing retaining wall at 16

    Magnolia. Staff determined that the retaining wall at 16 Magnolia was approved by the HPC in January

    2000.

    In considering the appropriateness of the proposed retaining wall Staff considerers several elements: the

    5

  • I.H & I.I

    materials, placement, dimensions, and the fact that a previous composition of the HPC approved a wall of

    the exact design and materials. First, Staff finds the rustic natural stone to be compatible with the subject

    property and surrounding district. Second, the wall is set back from the edge of the sidewalk, so as to

    retain a bit more of a sense of openness. Third, the 3’ height will not loom over pedestrians and aligns

    with the front walk, making it no taller than necessary. And fourth, while HPC decisions do not set

    precedent, the fact that a previous make-up of the HPC approved a retaining wall of the same materials

    and design, almost twice as tall next door, leads Staff to conclude that the proposal is compatible with the

    resource and surrounding district.

    There is a second retaining wall proposed as part of this project. On the western edge of 16 Magnolia, the

    applicant proposes to construct a retaining wall and set of stairs to connect the two properties. The

    placement of this wall and stairs is such that it will not be visible from the public right-of-way which,

    according to the Design Guidelines, should be approved as a matter of course.

    Fencing and Arbor

    The applicant proposes to enclose the rear of 23 West Irving in a 42” (forty-two inch) wood picket fence

    on the west side of the house, which transitions into a 6’ (six foot tall) vertical wood board on board

    privacy fence to enclose the property on the west and north property boundaries. To the east of the house,

    the applicant proposes to install a 42” (forty-two inch) tall board on board trash enclosure. The materials,

    designs, and dimensions are consistent with the HPC’s general fence guidance in historic districts. Staff

    finds the proposed fencing appropriate and recommends approval of the fencing at 23 West Irving.

    At 16 Magnolia, the applicant proposes to construct a section of 42’ (forty-two inch) wood board on

    board fencing on the new retaining wall to match the fencing installing on the south retaining wall. Staff

    finds this is an appropriate design and material and will only be minimally visible from the public right-

    of-way. At the southwest edge of the stone paving area at 16 Magnolia, the applicant proposes to install a

    wood and metal arbor. The arbor will have a painted metal frame with wood slats above. Staff finds that

    garden structures, such as the one proposed in this HAWP, are found throughout the District; and that this

    arbor will only be partially visible from an oblique angle in front of 23 West Irving. Staff finds that the

    proposed fencing and arbor at 16 Magnolia are consistent with the character of the resource and the

    surrounding district and recommends HPC approval.

    STAFF RECOMMENDATION:

    Staff recommends that the Commission approve the HAWP applications under the Criteria for Issuance

    in Chapter 24A-8(b)(1), (2), and (d), having found that the proposal will not substantially alter the

    exterior features of the historic resources and is compatible in character with the district and the purposes

    of Chapter 24A;

    and with the Secretary of the Interior’s Standards for Rehabilitation #2;

    and with the general condition that the applicant shall present the 3 permit sets of drawings, if

    applicable, to Historic Preservation Commission (HPC) staff for review and stamping prior to

    submission for the Montgomery County Department of Permitting Services (DPS) building permits;

    and with the general condition that final project design details, not specifically delineated by the

    Commission, shall be approved by HPC staff or brought back to the Commission as a revised HAWP

    application at staff’s discretion;

    and with the general condition that the applicant shall notify the Historic Preservation Staff if they

    propose to make any alterations to the approved plans. Once the work is completed the applicant will

    contact the staff person assigned to this application at 301-563-3400 or

    6

  • I.H & I.I

    [email protected] to schedule a follow-up site visit.

    7

    mailto:[email protected]

  • 919289

    8

  • 9

  • 10

  • Marc Elrich County Executive

    Mitra Pedoeem Director

    HISTORIC AREA WORK PERMIT APPLICATION Application Date: 7/8/2020

    Application No: 919289 AP Type: HISTORIC

    Customer No: 1378027

    255 Rockville Pike, 2nd Floor · Rockville, MD 20850 · (240)777-0311 · (240)777-6256 TTY www.montgomerycountymd.gov/dps

    DEPARTMENT OF PERMITTING SERVICES

    Affidavit AcknowledgementThe Contractor is the Primary applicant authorized by the property owner

    This application does not violate any covenants and deed restrictions Primary Applicant Information

    Address 16 MAGNOLIA PKWY CHEVY CHASE, MD 20815Othercontact Clinton & Associates (Primary)

    Historic Area Work Permit DetailsWork Type ADDScope ofWork

    Demolition of existing and addition of new stone terraces and walkways. Addition of stone retaining walls, arbor, fencing and planting. Expansionof existing parking court.

    11

  • CHEVY CHASE VILLAGE 5906 Connecticut Avenue Chevy Chase, Maryland 20815

    Phone (301) 654-7300

    Fax (301) 907-9721

    [email protected] www.chevychasevillagemd.gov

    BOARD OF MANAGERS

    ELISSA A. LEONARD Chair

    GARY CROCKETT Treasurer VILLAGE MANAGER

    SHANA R. DAVIS-COOK ROBERT C. GOODWIN, JR. Vice Chair

    NANCY E. WATTERS Assistant Treasurer LEGAL COUNSEL

    SUELLEN M. FERGUSON DAVID L. WINSTEAD Secretary

    LINDA J. WILLARD Board Member

    RICHARD M. RUDA Assistant Secretary

    Municipality Letter for

    Proposed Construction Project

    Subject Property: 16 Magnolia Parkway, Chevy Chase MD 20815

    Property Owner: Michael and Adena Friedman

    Project Manager/Contractor: Clinton & Associates/Sandra Clinton

    Proposed Work: Landscaping and architectural changes, including

    constructing new walls, patios, fences, plantings and

    arbor

    6/23/2020

    Diane R. Schwartz Jones, Director

    Department of Permitting Services of Montgomery County

    255 Rockville Pike, 2nd floor

    Rockville, MD 20850

    Dear Ms. Jones,

    This letter is to inform your department that the above homeowner/contractor has

    notified Chevy Chase Village that he or she plans to apply for both county and

    municipal permits for the above summarized construction project. Chevy Chase Village

    will not issue any municipal building permit(s) for this proposed project until

    Montgomery County has issued all necessary county permits and the applicant has

    provided Chevy Chase Village with copies of county-approved and stamped plans. We

    have advised the homeowner/contractor that a permit from Montgomery County does

    not guarantee a permit from this municipality unless the project complies with all our

    municipal rules and regulations.

    If this homeowner/contractor later applies for an amended county permit, please do not

    approve that application until you have received a Municipality Letter from us

    indicating that the homeowner/contractor has notified us of that proposed amendment to

    the permit.

    If you have any questions about this proposed project and the municipal regulation of it

    by Chevy Chase Village, do not hesitate to have your staff contact my office. The

    Village Permitting Coordinator can be reached by phone at 301-654-7300 or by e-mail

    at [email protected].

    Sincerely,

    Shana R. Davis-Cook

    Manager, Chevy Chase Village

    12

    mailto:[email protected]://www.chevychasevillagemd.gov/mailto:[email protected]

  • 3'-0"

    MIN

    .

    07/08/2020 20001

    5200 BALTIMORE AVENUE, SUITE 201

    HYATTSVILLE, MARYLAND 20781

    301.699.5600 WWW.CLINTON-LA.COM

    © C

    OP

    YR

    IG

    HT

    C

    LIN

    TO

    N &

    A

    SSO

    CIA

    TE

    S, P

    C 2

    02

    0

    MOCO HISTORIC

    AREA WORK

    PERMIT

    S:\CAD\Residential\20001 - Adena And Mike Friedman\Working Files\WORKING SHEET FILES FOR REGULATORY SUBMISSIONS\Friedman - HPC SHEETS.dwg

    N

    SCALE: 1/8" = 1'-0"

    8'0 4'2' 16'

    16 MAGNOLIA PKWY SITE PLAN

    A

    16

    M

    AG

    NO

    LIA

    P

    AR

    KW

    AY

    CH

    EV

    Y C

    HA

    SE

    , M

    D 2

    08

    15

    EX. CONDITIONS-

    SURVEY

    13

    AutoCAD SHX Text5" MAP.

    AutoCAD SHX Text9" MAP.

    AutoCAD SHX Text10" ASH

    AutoCAD SHX Text12" STUMP

    AutoCAD SHX Text24" ASH

    AutoCAD SHX Text15" ELM

    AutoCAD SHX Text15" MAP.

    AutoCAD SHX Text26" MAP.

    AutoCAD SHX Text18" MAP.

    AutoCAD SHX Text6" CRAPE MYRTLE

    AutoCAD SHX Text14" OAK

    AutoCAD SHX Text12" HICK.

    AutoCAD SHX Text20" OAK

    AutoCAD SHX Text5" SYC.

    AutoCAD SHX Text4" SYC.

    AutoCAD SHX Text20" BEE.

    AutoCAD SHX Text32" HICK.

    AutoCAD SHX Text47" POP.

    AutoCAD SHX TextE

    AutoCAD SHX Text7" DOG.

    AutoCAD SHX Text5" DOG.

    AutoCAD SHX Text2" MAP.

    AutoCAD SHX Text2" MAP.

    AutoCAD SHX Text5" TREE

    AutoCAD SHX TextE

    AutoCAD SHX Text3" MAP.

    AutoCAD SHX Text17" POP.

    AutoCAD SHX Text8" HOLLY

    AutoCAD SHX Text3" MAP

    AutoCAD SHX Text7" MAP

    AutoCAD SHX Text2" MAP

    AutoCAD SHX Text4" TREE

    AutoCAD SHX Text6" MAP

    AutoCAD SHX Text10" MAG.

    AutoCAD SHX Text4" HOLLY

    AutoCAD SHX Text10" CHER.

    AutoCAD SHX Text10" CHER.

    AutoCAD SHX Text3" HOLLY

    AutoCAD SHX Text3" TREE

    AutoCAD SHX Text5" HOLLY

    AutoCAD SHX Text3" HOLLY

    AutoCAD SHX Text4" TREE

    AutoCAD SHX Text4" HOLLY

    AutoCAD SHX Text3" HOLLY TWIN

    AutoCAD SHX Text7" MAG.

    AutoCAD SHX Text13" MAG.

    AutoCAD SHX TextS

    AutoCAD SHX TextWV

    AutoCAD SHX TextWV

    AutoCAD SHX TextEX. BRICK WALK

    AutoCAD SHX TextEX. BRICK WALK

    AutoCAD SHX TextGM

    AutoCAD SHX TextEX. BRICK WALK

    AutoCAD SHX TextEX. CONC. HANDICAP RAMPS

    AutoCAD SHX TextTW:341.83

    AutoCAD SHX TextTW:339.93

    AutoCAD SHX TextTW:341.76

    AutoCAD SHX TextEX. CONC. WALK

    AutoCAD SHX TextEX. STOP SIGN

    AutoCAD SHX TextEX. INLET

    AutoCAD SHX TextEX. INLET

    AutoCAD SHX TextEX. STONE WALK

    AutoCAD SHX TextEX. SLATE PATIO

    AutoCAD SHX Text32

    AutoCAD SHX TextEX. BRICK WALK

    AutoCAD SHX TextEX. SLATE WALK

    AutoCAD SHX TextEX. CONC. COLUMN

    AutoCAD SHX TextEX. FOUNTAIN

    AutoCAD SHX TextEX. STONE COLUMN

    AutoCAD SHX TextEX. SLATE PATIO

    AutoCAD SHX TextEX. SLATE PATIO

    AutoCAD SHX TextEX. SLATE WALK

    AutoCAD SHX TextEM

    AutoCAD SHX TextEX. CONC. LANDING

    AutoCAD SHX TextEX. CONC. LANDING

    AutoCAD SHX TextEX. CONC. COLUMN

    AutoCAD SHX TextEX. STONE WALK

    AutoCAD SHX TextSTORAGE LOCKER

    AutoCAD SHX TextEX. CONC. COLUMN

    AutoCAD SHX Text41x2

    AutoCAD SHX Text37x4

    AutoCAD SHX Text39x3

    AutoCAD SHX Text41x7

    AutoCAD SHX Text41x9

    AutoCAD SHX Text42x5

    AutoCAD SHX Text42x0

    AutoCAD SHX Text42x2

    AutoCAD SHX Text42x3

    AutoCAD SHX Text41x7

    AutoCAD SHX Text43x1

    AutoCAD SHX Text43x0

    AutoCAD SHX Text42x6

    AutoCAD SHX Text42x8

    AutoCAD SHX Text43x2

    AutoCAD SHX Text42x7

    AutoCAD SHX Text42x0

    AutoCAD SHX Text41x8

    AutoCAD SHX Text40x6

    AutoCAD SHX Text39x2

    AutoCAD SHX Text42x9

    AutoCAD SHX Text42x6

    AutoCAD SHX Text42x5

    AutoCAD SHX Text42x4

    AutoCAD SHX Text43x8

    AutoCAD SHX Text43x7

    AutoCAD SHX Text43x3

    AutoCAD SHX Text43x6

    AutoCAD SHX Text43x2

    AutoCAD SHX Text43x2

    AutoCAD SHX Text42x9

    AutoCAD SHX Text43x2

    AutoCAD SHX Text42x8

    AutoCAD SHX Text43x3

    AutoCAD SHX Text43x6

    AutoCAD SHX Text43x2

    AutoCAD SHX Text41x2

    AutoCAD SHX Text35x9

    AutoCAD SHX Text41x4

    AutoCAD SHX Text42x8

    AutoCAD SHX Text42x2

    AutoCAD SHX Text43x1

    AutoCAD SHX Text42x7

    AutoCAD SHX Text42x6

    AutoCAD SHX Text42x2

    AutoCAD SHX Text41x7

    AutoCAD SHX Text42x5

    AutoCAD SHX Text42x4

    AutoCAD SHX Text42x7

    AutoCAD SHX Text42x3

    AutoCAD SHX Text43x0

    AutoCAD SHX Text42x2

    AutoCAD SHX Text42x7

    AutoCAD SHX Text42x7

    AutoCAD SHX Text43x1

    AutoCAD SHX Text42x6

    AutoCAD SHX Text42x6

    AutoCAD SHX Text42x4

    AutoCAD SHX Text42x1

    AutoCAD SHX Text42x1

    AutoCAD SHX Text42x2

    AutoCAD SHX Text42x3

    AutoCAD SHX Text43x2

    AutoCAD SHX Text43x7

    AutoCAD SHX Text41x0

    AutoCAD SHX Text41x4

    AutoCAD SHX Text41x4

    AutoCAD SHX Text41x4

    AutoCAD SHX Text41x7

    AutoCAD SHX Text41x3

    AutoCAD SHX Text41x1

    AutoCAD SHX Text41x1

    AutoCAD SHX Text40x7

    AutoCAD SHX Text41x7

    AutoCAD SHX Text36x7

    AutoCAD SHX Text34x8

    AutoCAD SHX Text38x6

    AutoCAD SHX Text37x3

    AutoCAD SHX TextEX. STONE WALK

    AutoCAD SHX Text342

    AutoCAD SHX Text342

    AutoCAD SHX Text336

    AutoCAD SHX Text338

    AutoCAD SHX Text342

    AutoCAD SHX Text342

    AutoCAD SHX Text342

    AutoCAD SHX Text342

    AutoCAD SHX Text340

    AutoCAD SHX Text340

    AutoCAD SHX TextEX. ELEC. OUTLET

    AutoCAD SHX TextWM

    AutoCAD SHX TextEX. STONE STEPS

    AutoCAD SHX Text38x0

    AutoCAD SHX Text43x0

    AutoCAD SHX Text42x8

    AutoCAD SHX Text41x7

    AutoCAD SHX Text42x4

    AutoCAD SHX Text42x7

    AutoCAD SHX Text42x5

    AutoCAD SHX Text41x2

    AutoCAD SHX Text41x4

    AutoCAD SHX Text41x0

    AutoCAD SHX Text40x7

    AutoCAD SHX Text41x1

    AutoCAD SHX Text41x0

    AutoCAD SHX Text40x5

    AutoCAD SHX Text41x0

    AutoCAD SHX Text38x9

    AutoCAD SHX Text37x1

    AutoCAD SHX Text37x3

    AutoCAD SHX Text36x6

    AutoCAD SHX Text36x2

    AutoCAD SHX Text35x5

    AutoCAD SHX Text34x6

    AutoCAD SHX Text34x3

    AutoCAD SHX Text33x7

    AutoCAD SHX Text42x8

    AutoCAD SHX Text42x5

    AutoCAD SHX Text42x4

    AutoCAD SHX Text42x4

    AutoCAD SHX Text43x7

    AutoCAD SHX Text42x8

    AutoCAD SHX Text41x7

    AutoCAD SHX Text39x9

    AutoCAD SHX Text39x4

    AutoCAD SHX Text39x0

    AutoCAD SHX Text39x5

    AutoCAD SHX Text39x7

    AutoCAD SHX Text39x2

    AutoCAD SHX Text40x3

    AutoCAD SHX Text39x9

    AutoCAD SHX Text40x3

    AutoCAD SHX Text40x4

    AutoCAD SHX Text37x4

    AutoCAD SHX Text37x2

    AutoCAD SHX Text39x5

    AutoCAD SHX Text42x3

    AutoCAD SHX Text38x7

    AutoCAD SHX Text41x6

    AutoCAD SHX Text42x2

    AutoCAD SHX TextADENA AND MIKE FRIEDMAN

    AutoCAD SHX TextDate

    AutoCAD SHX TextSheet Number

    AutoCAD SHX TextProject #

    AutoCAD SHX TextSubmission

    AutoCAD SHX TextRev

    AutoCAD SHX TextDate

    AutoCAD SHX TextDescription

    AutoCAD SHX TextSheet Title

    AutoCAD SHX TextStamp

    AutoCAD SHX TextSURVEY

  • 3'-0"

    MIN

    .

    13'-6"

    TYP.

    07/08/2020 20001

    5200 BALTIMORE AVENUE, SUITE 201

    HYATTSVILLE, MARYLAND 20781

    301.699.5600 WWW.CLINTON-LA.COM

    © C

    OP

    YR

    IG

    HT

    C

    LIN

    TO

    N &

    A

    SSO

    CIA

    TE

    S, P

    C 2

    02

    0

    MOCO HISTORIC

    AREA WORK

    PERMIT

    S:\CAD\Residential\20001 - Adena And Mike Friedman\Working Files\WORKING SHEET FILES FOR REGULATORY SUBMISSIONS\Friedman - HPC SHEETS.dwg

    SITE PLAN- 16

    MAGNOLIA PKWY

    M

    A

    G

    N

    O

    L

    I

    A

    P

    A

    R

    K

    W

    A

    Y

    WEST IRVING STREET

    16 MAGNOLIA

    RESIDENCE

    GARAGE/

    STORAGE

    EXISTING PARKING COURT

    INFILL PLANTING TO ENHANCE

    EXISTING PLANTING

    INFILL PLANTING TO ENHANCE

    EXISTING PLANTING

    EXISTING STAIR AND RETAINING WALL

    TO REMAIN

    LAWN

    VEGETABLE GARDEN BED

    EXISTING STAIR

    TO REMAIN

    LAWN

    PROPERTY LINE

    PROPOSED EVERGREEN TREE

    PROPOSED DECIDUOUS TREE

    PROPOSED SHRUB

    EXISTING TREE

    PROPERTY LINE

    PROPOSED WALL

    PROPOSED STEPPING STONE

    WALKWAY

    LEGEND

    EXISTING WALL

    PROPOSED GROUND COVER

    AND PERENNIAL PLANTING

    BUILDING RESTRICTION LINE

    EXISTING FRONT AND SIDE PORCH

    AND STAIRS TO REMAIN

    RELOCATED GENERATOR

    EXTENSION OF EXISTING

    PARKING COURT

    A

    L200B

    NATURAL STONE PAVING

    D

    L201B

    PERENNIAL AND

    GROUND COVER PLANTING

    D

    L200B

    FENCE TO MATCH EXISTING

    42" HT. PICKET FENCE

    C

    L200B

    STONE STAIR

    A

    L200B

    NATURAL STONE PAVING

    A

    L200B

    NATURAL STONE PAVING

    EXISTING FENCE TO

    REMAIN

    B

    L200B

    STONE RETAINING WALL

    E

    L200B

    METAL AND WOOD

    ARBOR

    D

    L200B

    FENCE TO MATCH EXISTING

    42" HT. PICKET FENCE

    EXISTING FENCING TO REMAIN

    D

    L201B

    PERENNIAL AND

    GROUND COVER PLANTING

    D

    L201B

    PERENNIAL AND

    GROUND COVER PLANTING

    D

    L201B

    PERENNIAL AND

    GROUND COVER PLANTING

    B

    L201B

    EVERGREEN TREE

    PLANTING

    C

    L201B

    SHRUB PLANTING

    B

    L201B

    EVERGREEN TREE

    PLANTING

    B

    L201B

    EVERGREEN TREE

    PLANTING

    A

    L201B

    DECIDUOUS TREE

    PLANTING

    A

    L201B

    DECIDUOUS TREE

    PLANTING

    242.66

    242.35

    342.85

    242.70

    346.90

    343.20

    342.60

    343.10

    TS

    342.80

    TW

    343.10

    4R

    BS

    340.80

    TW

    343.10

    BW

    342.60

    BW

    342.90

    TS

    343.15

    343.50

    TW

    344.25

    TW

    343.95

    BS

    342.65

    1

    R

    342.00

    343.00

    342.60

    342.85

    342.70

    342.25

    342.50

    342.20

    342.30

    341.80

    342.40

    343.00

    342.50

    343.80

    346.80

    342.00

    335.90

    341.20

    341.40

    341.20

    342.40

    338.75PROPOSED ELEVATION

    EXISTING ELEVATION337.60

    CONTINUATION OF EXISTING

    STEPPING STONE PATH

    B

    L200B

    STONE RETAINING WALL

    TO MATCH EXISTING WALLS

    N

    SCALE: 1/8" = 1'-0"

    8'0 4'2' 16'

    16 MAGNOLIA PKWY SITE PLAN

    A

    16

    M

    AG

    NO

    LIA

    P

    AR

    KW

    AY

    CH

    EV

    Y C

    HA

    SE

    , M

    D 2

    08

    15

    E

    X

    IS

    T

    IN

    G

    D

    R

    IV

    E

    W

    A

    Y

    EXISTING PIERS AND

    FENCING TO REMAIN

    EXISTING STORAGE

    LOCKER TO REMAIN

    EXISTING BRICK SIDEWALK

    TO REMAIN

    EXISTING LAWN AND TREE

    PLANTING STRIP TO REMAIN

    A

    L100B

    EXISTING TREE TO BE REMOVED

    TBR 1

    TBR 2

    TBR 3

    TBR 4

    TBR 5

    TBR 6

    DOWNSPOUT

    1

    R

    STEP INDICATION (QNTY OF RISERS)

    TBR 1

    BUILT IN BENCH

    14

  • EXISTING STONE RETAINING WALL TO REMAIN

    3'-0"

    MA

    X.

    NEW

    RETAINING

    WALL

    RETAINING

    WALL AT 23

    WEST IRVING

    (UNDER

    SEPARATE

    PERMIT)

    07/08/2020 20001

    5200 BALTIMORE AVENUE, SUITE 201

    HYATTSVILLE, MARYLAND 20781

    301.699.5600 WWW.CLINTON-LA.COM

    © C

    OP

    YR

    IG

    HT

    C

    LIN

    TO

    N &

    A

    SSO

    CIA

    TE

    S, P

    C 2

    02

    0

    MOCO HISTORIC

    AREA WORK

    PERMIT

    S:\CAD\Residential\20001 - Adena And Mike Friedman\Working Files\WORKING SHEET FILES FOR REGULATORY SUBMISSIONS\Friedman - HPC SHEETS.dwg

    SECTIONS &

    ELEAVTIONS- 16

    MAGNOLIA PKWY

    16 MAGNOLIA PKWY WALL AND ARBOR ELEVATION (FROM WEST IRVING STREET)

    A

    16

    M

    AG

    NO

    LIA

    P

    AR

    KW

    AY

    CH

    EV

    Y C

    HA

    SE

    , M

    D 2

    08

    15

    SCALE: 1/4" = 1'-0"

    4'0 2'1' 8'

    D

    L201B

    PERENNIAL AND GROUND

    COVER PLANTING

    PROPERTY LINE

    A

    L201B

    DECIDUOUS TREE

    PLANTING

    B

    L201B

    EVERGREEN TREE

    PLANTING

    B

    L200B

    STONE RETAINING

    WALL TO MATCH

    EXISTING WALL

    EXISTING FENCE

    TO REMAIN

    F

    L200B

    WOOD AND METAL

    ARBOR

    EXISTING FENCE

    TO REMAIN

    15

  • 07/08/2020 20001

    5200 BALTIMORE AVENUE, SUITE 201

    HYATTSVILLE, MARYLAND 20781

    301.699.5600 WWW.CLINTON-LA.COM

    © C

    OP

    YR

    IG

    HT

    C

    LIN

    TO

    N &

    A

    SSO

    CIA

    TE

    S, P

    C 2

    02

    0

    MOCO HISTORIC

    AREA WORK

    PERMIT

    S:\CAD\Residential\20001 - Adena And Mike Friedman\Working Files\WORKING SHEET FILES FOR REGULATORY SUBMISSIONS\Friedman - HPC SHEETS- DETAILS.dwg

    16 MAGNOLIA

    PKWY DETAILS

    NATURAL STONE PAVING

    A1" = 1'-0"

    STONE RETAINING WALL, TO MATCH EXISTING

    B1" = 1'-0"

    FENCING, TO MATCH EXISTING

    DN.T.S.

    STONE STAIR

    C1" = 1'-0"

    METAL AND WOOD ARBOR PRECEDENT IMAGES

    EN.T.S.

    1

    12

    2" DIA. SCH. 40 PVC PIPE FOR

    WEEPHOLES, 8' O.C., RECESS

    BACK 2" FROM FACE OF WALL.

    LEAVE 1-1/4" GAP BETWEEN

    STONES IN FACE OF WALL FOR

    OUTFLOW.

    COMPACTED SUBGRADE TO 95%

    DENSITY

    2" MAX. DIA. DRAINAGE

    AGGREGATE CONTINUOUS ALONG

    BACK OF WALL. WRAP IN FILTER

    FABRIC (MIRAFI 140N) - OVERLAP

    JOINTS

    CARDEROCK STONE TO MATCH EXISTING

    WALLS

    TOP STONES NOT LESS THAN 6"

    THICK RANGING FROM 12" TO 30"

    IN LENGTH - FLUSH MORTAR

    JOINTS ON TOP SURFACE

    6"

    2"

    1'-2"

    24"

    PERENNIAL AND

    GROUND COVER

    PLANTING

    3'-0"

    MA

    X.

    1'-2"

    EX STONE WALL

    SUBGRADE COMPACTED TO 95%

    CR 6 STONE AGGREGATE BASE

    STONE DUST SETTING BED

    1/8" SAND SWEPT JOINTS

    2" TH. NATURAL STONE PAVER,

    SIZES VARY

    2"2"

    4"

    SUBGRADE COMPACTED TO 95%

    CR 6 STONE AGGREGATE BASE

    STONE DUST SETTING BED

    1/8" SAND SWEPT JOINTS

    4" TH. NATURAL STONE PAVER,

    SIZES VARY

    2"

    4"

    6"

    CONCRETE FOOTING

    2'-6" M

    IN

    .

    FILL COMPACTED TO 95% UNDER ENTIRE

    STAIR, FOOTINGS, AND SLAB

    1

    1

    2

    " TYP.

    12" MIN.

    12" MIN.

    ADJACENT CONDITION, VARIES

    #4 @ 12" O.C. EACH WAY (TYP.) AND

    AT NOSE OF EACH STEP

    2" THICK NATURAL STONE TREADS WITH THERMAL

    FINISH AT EXPOSED EDGES. SET RISER AND TREAD

    STONE IN 5/8" MORTAR SETTING BED.

    6"

    1'-2"

    STONE CHEEK WALL BEHIND STAIR

    HANDRAIL, AS REQUIRED, SEE SITE

    PLAN FOR LOCATIONS

    #4 DOWELS

    @8" O.C. (TYP.)

    CARDEROCK STONE RISER TO MATCH WALL

    STONE; NO VISIBLE MORTAR JOINTS; MORTAR

    COLOR SHALL MATCH STONE

    TRAVERTINE PAVING GRANITE COBBLESTONE PAVING

    EXISTING PICKET GATE

    EXISTING PICKET FENCING

    16

    M

    AG

    NO

    LIA

    P

    AR

    KW

    AY

    CH

    EV

    Y C

    HA

    SE

    , M

    D 2

    08

    15

    16

  • 07/08/2020 20001

    5200 BALTIMORE AVENUE, SUITE 201

    HYATTSVILLE, MARYLAND 20781

    301.699.5600 WWW.CLINTON-LA.COM

    © C

    OP

    YR

    IG

    HT

    C

    LIN

    TO

    N &

    A

    SSO

    CIA

    TE

    S, P

    C 2

    02

    0

    MOCO HISTORIC

    AREA WORK

    PERMIT

    S:\CAD\Residential\20001 - Adena And Mike Friedman\Working Files\WORKING SHEET FILES FOR REGULATORY SUBMISSIONS\Friedman - HPC SHEETS- DETAILS.dwg

    16 MAGNOLIA

    PKWY DETAILS

    DECIDUOUS TREE PLANTING

    A3/4" = 1'-0"

    PERENNIAL AND GROUND COVER PLANTING

    D1" = 1'-0"

    EVERGREEN TREE PLANTING

    B3/4" = 1'-0"

    SHRUB PLANTING

    C1" = 1'-0"

    SEE PLANT LIST

    FOR SPACING

    PLAN - TRIANGULAR SPACING

    NOT TO SCALE

    1/2" O.C. DIMENSION

    6" M

    IN

    .

    PREPARED PLANTING SOIL, DEPTH AS

    SPECIFIED, TAMP AND WATER WHEN

    BACKFILLING AROUND PLANT

    1" SHREDDED, COMPOSTED PINE BARK

    MULCH. INSTALL PRIOR TO PLANT

    INSTALLATION

    PRIOR TO BACKFILLING, CUT "POT-BOUND"

    ROOTS ON OUTSIDE; REMOVE 25%-50%

    OF BARK MIXTURE ON ROOT BALL.

    MIX REMOVED CONTAINER MATERIAL

    WITH BACKFILL.

    EDGE OF BED

    PLANT

    O.C. DIMENSION

    O

    .

    C

    .

    D

    I

    M

    E

    N

    S

    I

    O

    N

    6"

    3X WIDTH OF ROOT BALL DIAMETER

    FOR TREE WITH WIRE BASKET AROUND

    ROOT BALL, CUT WIRE BASKET IN FOUR

    PLACES & FOLD DOWN 12" INTO PLANTING

    HOLE

    TURN BACK TOP

    1

    3

    OF BURLAP AWAY FROM

    TOP OF ROOT BALL & CUT ROPE FROM TOP

    OF BALL

    2" COMPOSTED SHREDDED PINE BARK MULCH

    REMOVE ANY MULCH IN CONTACT WITH THE

    CROWN OF THE TREE

    ORIENT THE SIDE OF TREE WHICH FACED

    NORTH IN THE NURSERY TO FACE NORTH

    IN PLANTING AREA

    LOOP HOSE ABOVE FIRST SET OF BRANCHES

    GUYING SYSTEM: (2) 2" X 2" HARDWOOD

    STAKES PER TREE; 2 STRANDS GALVANIZED

    WIRE TWISTED FOR SUPPORT; EYESCREW &

    TURNBUCKLE;

    1

    2

    " HOSE LOOPS AT TRUNK

    PLACE

    1

    8

    OF ROOT BALL ABOVE ADJACENT

    FINISHED GRADE

    FINISHED GRADE

    PREPARED SOIL MIX AS SPECIFIED

    REMOVE DEBRIS & EXCESS SOIL FROM TOP OF

    ROOT BALL THAT MAY HAVE ACCUMULATED

    WHEN BURLAPPED

    UNDISTURBED SUBGRADE

    PLANTING MOUND TO INHIBIT SETTLING

    S

    L

    O

    P

    E

    A

    W

    A

    Y

    TEMPORARY SAUCER AROUND TREE

    6"

    GALVANIZED

    STEEL WIRE

    ROOT BALL

    TREE TRUNK

    HARDWOOD

    STAKE

    TREE TRUNK

    HARDWOOD STAKE

    GALVANIZED STEEL WIRE

    ROOT BALL

    PLAN VIEW

    TREES WITH WIRE BASKETS

    AROUND THE ROOT BALL SHALL

    HAVE THE WIRE CUT BACK & FOLDED

    DOWN 12" INTO THE PLANTING

    HOLE

    CUT ROPE AND TURN BACK TOP

    1/3 OF BURLAP AWAY FROM

    ROOT BALL

    BERM SOIL TO DRAIN AWAY

    FROM TREE

    1" COMPOSTED SHREDDED PINE

    BARK MULCH

    3 2"x4"x3' HARDWOOD STAKE

    REMOVE DEBRIS AND EXCESS SOIL

    FROM TOP OF ROOT BALL THAT

    MAY HAVE ACCUMULATED WHEN

    BURLAPPED

    UNDISTURBED SUBGRADE

    3 PIECES OF REINFORCED

    RUBBER HOSE (1 PER WIRE),

    BLACK OR DARK BROWN

    DOUBLE STRAND OF 12 GUAGE

    GALVANIZED WIRE TWISTED,

    THREE PER TREE.

    PLACE 1/8 OF ROOT

    BALL ABOVE ADJACENT

    FINISHED GRADE

    FINISH GRADE

    S

    L

    O

    P

    E

    A

    W

    A

    Y

    12" MIN.

    PREPARE PLANTING SOIL

    SEE PLANTING PLANS AND

    PLANT LIST FOR SPACING

    NOTE: FOR CONTAINER STOCK,

    PULL POTTING MIX AND ROOT MAT APART

    TO DIRECT THE OUTER ROOTS INTO ADJACENT SOIL.

    DO NOT LEAVE CIRCLING ROOTS AGAINST ROOT BALL

    FINISH GRADE

    PLACE TOP 1/8 OF ROOT BALL ABOVE FINISH GRADE

    CUT ROPE FROM TOP OF ROOT BALL & TURN

    BACK BURLAP FROM TOP 1/3 OF ROOT BALL

    1" SHREDDED, COMPOSTED PINE BARK MULCH

    PLANTING SOIL PREPARED AS SPECIFIED.

    TAMP AND WATER WHEN BACKFILLING AROUND PLANT

    16

    M

    AG

    NO

    LIA

    P

    AR

    KW

    AY

    CH

    EV

    Y C

    HA

    SE

    , M

    D 2

    08

    15

    17

  • 919315

    18

  • 19

  • 20

  • Marc Elrich County Executive

    Mitra Pedoeem Director

    HISTORIC AREA WORK PERMIT APPLICATION Application Date: 7/8/2020

    Application No: 919315 AP Type: HISTORIC

    Customer No: 1377824

    255 Rockville Pike, 2nd Floor · Rockville, MD 20850 · (240)777-0311 · (240)777-6256 TTY www.montgomerycountymd.gov/dps

    DEPARTMENT OF PERMITTING SERVICES

    Affidavit AcknowledgementThe Contractor is the Primary applicant authorized by the property owner

    This application does not violate any covenants and deed restrictions Primary Applicant Information

    Address 23 W IRVING ST CHEVY CHASE, MD 20815Othercontact Clinton and Associates (Primary) Historic Area Work Permit DetailsWorkType

    CONST

    Scope ofWork

    Add stone retaining wall in front yard. Remove existing rear yard terrace and side yard walkway and replace with new natural stone terrace andwalkway. Remove dissimilar, existing fencing and replace with fences that match in aesthetics.

    21

  • 07/08/2020 20001

    5200 BALTIMORE AVENUE, SUITE 201

    HYATTSVILLE, MARYLAND 20781

    301.699.5600 WWW.CLINTON-LA.COM

    © C

    OP

    YR

    IG

    HT

    C

    LIN

    TO

    N &

    A

    SSO

    CIA

    TE

    S, P

    C 2

    02

    0

    MOCO HISTORIC

    AREA WORK

    PERMIT

    S:\CAD\Residential\20001 - Adena And Mike Friedman\Working Files\WORKING SHEET FILES FOR REGULATORY SUBMISSIONS\Friedman - HPC SHEETS.dwg

    EX. CONDITIONS-

    SURVEY

    N

    SCALE: 1/8" = 1'-0"

    8'0 4'2' 16'

    23 WEST IRVING EXISTING CONDITIONS

    A

    23

    W

    EST

    IR

    VIN

    G ST

    RE

    ET

    CH

    EV

    Y C

    HA

    SE

    , M

    D 2

    08

    15

    22

    AutoCAD SHX Text14" MAP.

    AutoCAD SHX Text10" MAP

    AutoCAD SHX Text14" MAP.

    AutoCAD SHX Text2" MAP

    AutoCAD SHX Text10" ASH

    AutoCAD SHX Text12" STUMP

    AutoCAD SHX Text5" PINE

    AutoCAD SHX Text6" PINE

    AutoCAD SHX Text15" HOLLY

    AutoCAD SHX Text30" OAK

    AutoCAD SHX Text8" GUM

    AutoCAD SHX Text30" OAK

    AutoCAD SHX Text6" GUM

    AutoCAD SHX Text8" GUM

    AutoCAD SHX Text6" GUM MULTI

    AutoCAD SHX Text6" PINE

    AutoCAD SHX Text6" PINE

    AutoCAD SHX Text6" PINE

    AutoCAD SHX Text6" PINE

    AutoCAD SHX Text6" PINE

    AutoCAD SHX TextEX. INLET

    AutoCAD SHX TextGM

    AutoCAD SHX TextEM

    AutoCAD SHX TextEX. BRICK WALK

    AutoCAD SHX TextEX. CONC. APRON

    AutoCAD SHX TextEX. CONC./ BRICK WALK

    AutoCAD SHX TextEX. SLATE WALK

    AutoCAD SHX TextEX. SLATE PATIO

    AutoCAD SHX TextEX. COV'D PORCH

    AutoCAD SHX TextEX. CONC. WALK

    AutoCAD SHX TextEX. SLATE PATIO

    AutoCAD SHX TextTW:339.48

    AutoCAD SHX Text37x3

    AutoCAD SHX Text38x9

    AutoCAD SHX Text32x3

    AutoCAD SHX Text40x5

    AutoCAD SHX Text40x7

    AutoCAD SHX Text40x8

    AutoCAD SHX Text40x8

    AutoCAD SHX Text41x2

    AutoCAD SHX Text40x6

    AutoCAD SHX Text40x7

    AutoCAD SHX Text40x9

    AutoCAD SHX Text41x2

    AutoCAD SHX Text41x5

    AutoCAD SHX Text41x4

    AutoCAD SHX Text41x6

    AutoCAD SHX Text39x3

    AutoCAD SHX Text38x9

    AutoCAD SHX Text38x6

    AutoCAD SHX Text38x5

    AutoCAD SHX Text38x3

    AutoCAD SHX Text38x4

    AutoCAD SHX Text37x9

    AutoCAD SHX Text37x8

    AutoCAD SHX Text41x2

    AutoCAD SHX Text37x4

    AutoCAD SHX Text33x0

    AutoCAD SHX Text33x3

    AutoCAD SHX Text39x5

    AutoCAD SHX Text39x7

    AutoCAD SHX Text38x9

    AutoCAD SHX Text39x5

    AutoCAD SHX Text40x9

    AutoCAD SHX Text41x1

    AutoCAD SHX Text41x5

    AutoCAD SHX Text41x3

    AutoCAD SHX Text41x1

    AutoCAD SHX Text42x6

    AutoCAD SHX Text37x7

    AutoCAD SHX Text37x4

    AutoCAD SHX Text37x5

    AutoCAD SHX Text36x7

    AutoCAD SHX Text35x2

    AutoCAD SHX Text35x3

    AutoCAD SHX Text36x7

    AutoCAD SHX Text30x9

    AutoCAD SHX Text37x0

    AutoCAD SHX Text37x1

    AutoCAD SHX Text37x0

    AutoCAD SHX Text332

    AutoCAD SHX Text334

    AutoCAD SHX Text336

    AutoCAD SHX Text338

    AutoCAD SHX Text338

    AutoCAD SHX Text340

    AutoCAD SHX Text340

    AutoCAD SHX Text342

    AutoCAD SHX Text342

    AutoCAD SHX Text338

    AutoCAD SHX Text336

    AutoCAD SHX Text334

    AutoCAD SHX TextEX. CONC./ BRICK STEPS

    AutoCAD SHX TextEX. CONC./ BRICK STEPS

    AutoCAD SHX Text30" OAK

    AutoCAD SHX Text41x4

    AutoCAD SHX Text24" BEE.

    AutoCAD SHX Text40x7

    AutoCAD SHX Text41x7

    AutoCAD SHX Text41x6

    AutoCAD SHX Text41x2

    AutoCAD SHX Text39x6

    AutoCAD SHX Text41x2

    AutoCAD SHX Text32x3

    AutoCAD SHX Text30x4

    AutoCAD SHX TextADENA AND MIKE FRIEDMAN

    AutoCAD SHX TextDate

    AutoCAD SHX TextSheet Number

    AutoCAD SHX TextProject #

    AutoCAD SHX TextSubmission

    AutoCAD SHX TextRev

    AutoCAD SHX TextDate

    AutoCAD SHX TextDescription

    AutoCAD SHX TextSheet Title

    AutoCAD SHX TextStamp

    AutoCAD SHX TextSURVEY

  • CHEVY CHASE VILLAGE 5906 Connecticut Avenue Chevy Chase, Maryland 20815

    Phone (301) 654-7300

    Fax (301) 907-9721

    [email protected] www.chevychasevillagemd.gov

    BOARD OF MANAGERS

    ELISSA A. LEONARD Chair

    GARY CROCKETT Treasurer VILLAGE MANAGER

    SHANA R. DAVIS-COOK ROBERT C. GOODWIN, JR. Vice Chair

    NANCY E. WATTERS Assistant Treasurer LEGAL COUNSEL

    SUELLEN M. FERGUSON DAVID L. WINSTEAD Secretary

    LINDA J. WILLARD Board Member

    RICHARD M. RUDA Assistant Secretary

    Municipality Letter for

    Proposed Construction Project

    Subject Property: 23 West Irving Street, Chevy Chase MD 20815

    Property Owner: Michael and Adena Friedman

    Project Manager/Contractor: Clinton & Associates/Sandra Clinton

    Proposed Work: Landscaping and architectural changes, including

    constructing new walls, patios, fences and plantings

    6/23/2020

    Diane R. Schwartz Jones, Director

    Department of Permitting Services of Montgomery County

    255 Rockville Pike, 2nd floor

    Rockville, MD 20850

    Dear Ms. Jones,

    This letter is to inform your department that the above homeowner/contractor has

    notified Chevy Chase Village that he or she plans to apply for both county and

    municipal permits for the above summarized construction project. Chevy Chase Village

    will not issue any municipal building permit(s) for this proposed project until

    Montgomery County has issued all necessary county permits and the applicant has

    provided Chevy Chase Village with copies of county-approved and stamped plans. We

    have advised the homeowner/contractor that a permit from Montgomery County does

    not guarantee a permit from this municipality unless the project complies with all our

    municipal rules and regulations.

    If this homeowner/contractor later applies for an amended county permit, please do not

    approve that application until you have received a Municipality Letter from us

    indicating that the homeowner/contractor has notified us of that proposed amendment to

    the permit.

    If you have any questions about this proposed project and the municipal regulation of it

    by Chevy Chase Village, do not hesitate to have your staff contact my office. The

    Village Permitting Coordinator can be reached by phone at 301-654-7300 or by e-mail

    at [email protected].

    Sincerely,

    Shana R. Davis-Cook

    Manager, Chevy Chase Village

    23

    mailto:[email protected]://www.chevychasevillagemd.gov/mailto:[email protected]

  • 3'-0

    "

    MIN

    .

    07/08/2020 20001

    5200 BALTIMORE AVENUE, SUITE 201

    HYATTSVILLE, MARYLAND 20781

    301.699.5600 WWW.CLINTON-LA.COM

    © C

    OP

    YR

    IG

    HT

    C

    LIN

    TO

    N &

    A

    SSO

    CIA

    TE

    S, P

    C 2

    02

    0

    MOCO HISTORIC

    AREA WORK

    PERMIT

    S:\CAD\Residential\20001 - Adena And Mike Friedman\Working Files\WORKING SHEET FILES FOR REGULATORY SUBMISSIONS\Friedman - HPC SHEETS.dwg

    SITE PLAN- 23

    WEST IRVING

    N

    SCALE: 1/8" = 1'-0"

    8'0 4'2' 16'

    WEST IRVING STREET

    23 WEST IRVING

    RESIDENCE

    SIDE PORCH

    LAWN

    LAWN

    NEW STEPPING STONE

    PATH

    LAWN

    LAWN

    EXISTING STAIR, HANDRAILS

    AND WALKWAY TO REMAIN

    EXISTING STAIR, PORCH

    AND HANDRAILS TO REMAIN

    EXISTING SIDEWALK

    PROPERTY LINE

    PROPERTY LINE

    PROPOSED EVERGREEN TREE

    PROPOSED DECIDUOUS TREE

    PROPOSED SHRUB

    EXISTING TREE

    PROPERTY LINE

    PROPOSED WALL

    PROPOSED STEPPING STONE

    WALKWAY

    LEGEND

    EXISTING WALL

    PROPOSED GROUND COVER

    AND PERENNIAL PLANTING

    BUILDING RESTRICTION LINE

    D

    L200A

    STONE STAIR

    D

    L200A

    STONE STAIR

    A

    L200A

    NATURAL STONE PAVING

    G

    L200A

    EVERGREEN TREE

    PLANTING

    F

    L200A

    DECIDUOUS TREE

    PLANTING

    E

    L200A

    NEW PERIMETER FENCE, 6'HT.-

    VERTICAL BOARD ON BOARD

    A

    L200A

    NATURAL STONE PAVING

    I

    L200A

    PERENNIAL AND

    GROUND COVER PLANTING

    H

    L200A

    PERENNIAL AND

    GROUND COVER PLANTING

    G

    L200A

    EVERGREEN TREE

    PLANTING

    I

    L200A

    PERENNIAL AND

    GROUND COVER PLANTING

    H

    L200A

    SHRUB PLANTING

    I

    L200A

    PERENNIAL AND

    GROUND COVER PLANTING

    B

    L200A

    STONE RETAINING WALL, MATERIALS

    AND CONSTRUCTION TO MATCH NEIGHBORING WALLS

    AT 16 MAGNOLIA PKWY

    E

    L200A

    TRASH ENCLOSURE FENCING, 42" HT.

    VERTICAL BOARD ON BOARD

    BS

    340.80

    TS

    341.80

    2R

    BS

    339.00

    TS

    340.00

    TW

    337.65

    TW

    337.65

    TW

    342.05

    TW

    340.50

    BW

    334.65

    BW

    334.65

    TW

    337.65

    TW

    337.65

    TW

    335.00

    BW

    332.00

    BW

    334.75

    340.80

    340.40

    TS

    340.50

    BS

    340.00

    1

    R

    339.50

    340.80

    340.40

    TW

    341.14

    TW

    335.00

    333.10

    337.40

    337.60

    340.90

    339.10

    332.30

    338.75PROPOSED ELEVATION

    EXISTING ELEVATION337.60

    A

    L100A

    23 WEST IRVING SITE PLAN

    A

    B

    L1

    00

    A

    C

    L200A

    STONE SEAT WALL

    23

    W

    EST

    IR

    VIN

    G ST

    RE

    ET

    CH

    EV

    Y C

    HA

    SE

    , M

    D 2

    08

    15

    B

    L200A

    STONE RETAINING WALL, MATERIALS

    AND CONSTRUCTION TO MATCH NEIGHBORING WALLS

    AT 16 MAGNOLIA PKWY

    EXISTING LAWN AND TREE

    STRIP PLANTING TO REMAIN

    TBR 1

    TBR 2

    TBR 3

    TBR 4

    TBR 5

    TBR 6

    TBR 7

    TBR 8

    TBR 9

    EXISTING TREE TO BE REMOVED

    DOWNSPOUT

    1

    R

    STEP INDICATION (QNTY OF RISERS)

    TBR 1

    TBR 10

    TBR 11

    E

    L200A

    NEW 42'HT. PICKET FENCE

    24

  • PERENNIAL

    AND GROUND

    COVER

    PLANTING

    H/ L200A

    NEW STONE RETAINING WALL,

    MATERIALS AND CONSTRUCTION

    TO MATCH NEIGHBORING WALL AT

    16 MAGNOLIA PKWY

    B/ L200A

    EXISTING

    STAIR

    AND

    HANDRAIL

    TO

    REMAIN

    NEW STONE RETAINING WALL, MATERIALS

    AND CONSTRUCTION TO MATCH

    NEIGHBORING WALL AT 16 MAGNOLIA

    PKWY

    B/ L200A

    STONE RETAINING

    WALL AT 16

    MAGNOLIA PKWY

    (UNDER SEPARATE

    PERMIT

    3'-0

    "

    MA

    X.

    EXISTING

    WALL

    3'-0"

    MAX

    3'-0

    "

    MA

    X.

    07/08/2020 20001

    5200 BALTIMORE AVENUE, SUITE 201

    HYATTSVILLE, MARYLAND 20781

    301.699.5600 WWW.CLINTON-LA.COM

    © C

    OP

    YR

    IG

    HT

    C

    LIN

    TO

    N &

    A

    SSO

    CIA

    TE

    S, P

    C 2

    02

    0

    MOCO HISTORIC

    AREA WORK

    PERMIT

    S:\CAD\Residential\20001 - Adena And Mike Friedman\Working Files\WORKING SHEET FILES FOR REGULATORY SUBMISSIONS\Friedman - HPC SHEETS.dwg

    FRONT WALL

    ELEVATION- 23

    WEST IRVING

    SCALE: 1/4" = 1'-0"

    4'0 2'1' 8'

    23 WEST IRVING FRONT WALL ELEVATION

    A

    PROPERTY LINE

    E

    L200A

    DECIDUOUS TREE

    PLANTING

    H

    L200A

    PERENNIAL AND GROUND

    COVER PLANTING

    EXISTING

    SIDEWALK TO

    REMAIN

    23 WEST IRVING FRONT WALL SECTION

    B SCALE: 1/4" = 1'-0"

    4'0 2'1' 8'

    E

    L200A

    DECIDUOUS TREE

    PLANTING

    H

    L200A

    PERENNIAL AND GROUND

    COVER PLANTING

    B

    L200A

    NEW STONE RETAINING WALL

    TO MATCH NEIGHBORING WALL

    AT 16 MAGNOLIA PKWY

    H

    L200A

    PERENNIAL AND GROUND

    COVER PLANTING

    EXISTING BRICK

    WALKWAY TO REMAIN

    EXISTING GRADE

    23

    W

    EST

    IR

    VIN

    G ST

    RE

    ET

    CH

    EV

    Y C

    HA

    SE

    , M

    D 2

    08

    15

    PROPERTY LINE

    25

  • 07/08/2020 20001

    5200 BALTIMORE AVENUE, SUITE 201

    HYATTSVILLE, MARYLAND 20781

    301.699.5600 WWW.CLINTON-LA.COM

    © C

    OP

    YR

    IG

    HT

    C

    LIN

    TO

    N &

    A

    SSO

    CIA

    TE

    S, P

    C 2

    02

    0

    MOCO HISTORIC

    AREA WORK

    PERMIT

    S:\CAD\Residential\20001 - Adena And Mike Friedman\Working Files\WORKING SHEET FILES FOR REGULATORY SUBMISSIONS\Friedman - HPC SHEETS- DETAILS.dwg

    23 WEST IRVING

    DETAILS

    NATURAL STONE PAVING

    A1" = 1'-0"

    STONE RETAINING WALL TO MATCH NEIGHBORING WALL AT 16 MAGNOLIA PKWY

    B1" = 1'-0"

    FENCING TO MATCH EXISTING, ADJACENT FENCE

    EN.T.S.

    STONE STAIR

    D1" = 1'-0"

    DECIDUOUS TREE PLANTING

    F3/4" = 1'-0"

    EVERGREEN TREE PLANTING

    G3/4" = 1'-0"

    SHRUB PLANTING

    H1" = 1'-0"

    PERENNIAL AND GROUND COVER PLANTING

    I1" = 1'-0"

    SUBGRADE COMPACTED TO 95%

    CR 6 STONE AGGREGATE BASE

    STONE DUST SETTING BED

    1/8" SAND SWEPT JOINTS

    2" TH. NATURAL STONE PAVER,

    SIZES VARY

    2"2"

    4"

    SUBGRADE COMPACTED TO 95%

    CR 6 STONE AGGREGATE BASE

    STONE DUST SETTING BED

    1/8" SAND SWEPT JOINTS

    4" TH. NATURAL STONE PAVER,

    SIZES VARY

    2"

    4"

    6"

    TRAVERTINE PAVING GRANITE COBBLESTONE PAVING

    6"

    3X WIDTH OF ROOT BALL DIAMETER

    FOR TREE WITH WIRE BASKET AROUND

    ROOT BALL, CUT WIRE BASKET IN FOUR

    PLACES & FOLD DOWN 12" INTO PLANTING

    HOLE

    TURN BACK TOP

    1

    3

    OF BURLAP AWAY FROM

    TOP OF ROOT BALL & CUT ROPE FROM TOP

    OF BALL

    2" COMPOSTED SHREDDED PINE BARK MULCH

    REMOVE ANY MULCH IN CONTACT WITH THE

    CROWN OF THE TREE

    ORIENT THE SIDE OF TREE WHICH FACED

    NORTH IN THE NURSERY TO FACE NORTH

    IN PLANTING AREA

    LOOP HOSE ABOVE FIRST SET OF BRANCHES

    GUYING SYSTEM: (2) 2" X 2" HARDWOOD

    STAKES PER TREE; 2 STRANDS GALVANIZED

    WIRE TWISTED FOR SUPPORT; EYESCREW &

    TURNBUCKLE;

    1

    2

    " HOSE LOOPS AT TRUNK

    PLACE

    1

    8

    OF ROOT BALL ABOVE ADJACENT

    FINISHED GRADE

    FINISHED GRADE

    PREPARED SOIL MIX AS SPECIFIED

    REMOVE DEBRIS & EXCESS SOIL FROM TOP OF

    ROOT BALL THAT MAY HAVE ACCUMULATED

    WHEN BURLAPPED

    UNDISTURBED SUBGRADE

    PLANTING MOUND TO INHIBIT SETTLING

    S

    L

    O

    P

    E

    A

    W

    A

    Y

    TEMPORARY SAUCER AROUND TREE

    6"

    GALVANIZED

    STEEL WIRE

    ROOT BALL

    TREE TRUNK

    HARDWOOD

    STAKE

    SEE PLANT LIST

    FOR SPACING

    PLAN - TRIANGULAR SPACING

    NOT TO SCALE

    1/2" O.C. DIMENSION

    6" M

    IN

    .

    PREPARED PLANTING SOIL, DEPTH AS

    SPECIFIED, TAMP AND WATER WHEN

    BACKFILLING AROUND PLANT

    1" SHREDDED, COMPOSTED PINE BARK

    MULCH. INSTALL PRIOR TO PLANT

    INSTALLATION

    PRIOR TO BACKFILLING, CUT "POT-BOUND"

    ROOTS ON OUTSIDE; REMOVE 25%-50%

    OF BARK MIXTURE ON ROOT BALL.

    MIX REMOVED CONTAINER MATERIAL

    WITH BACKFILL.

    EDGE OF BED

    PLANT

    O.C. DIMENSION

    O

    .

    C

    .

    D

    I

    M

    E

    N

    S

    I

    O

    N

    TREE TRUNK

    HARDWOOD STAKE

    GALVANIZED STEEL WIRE

    ROOT BALL

    PLAN VIEW

    TREES WITH WIRE BASKETS

    AROUND THE ROOT BALL SHALL

    HAVE THE WIRE CUT BACK & FOLDED

    DOWN 12" INTO THE PLANTING

    HOLE

    CUT ROPE AND TURN BACK TOP

    1/3 OF BURLAP AWAY FROM

    ROOT BALL

    BERM SOIL TO DRAIN AWAY

    FROM TREE

    1" COMPOSTED SHREDDED PINE

    BARK MULCH

    3 2"x4"x3' HARDWOOD STAKE

    REMOVE DEBRIS AND EXCESS SOIL

    FROM TOP OF ROOT BALL THAT

    MAY HAVE ACCUMULATED WHEN

    BURLAPPED

    UNDISTURBED SUBGRADE

    3 PIECES OF REINFORCED

    RUBBER HOSE (1 PER WIRE),

    BLACK OR DARK BROWN

    DOUBLE STRAND OF 12 GUAGE

    GALVANIZED WIRE TWISTED,

    THREE PER TREE.

    PLACE 1/8 OF ROOT

    BALL ABOVE ADJACENT

    FINISHED GRADE

    FINISH GRADE

    S

    L

    O

    P

    E

    A

    W

    A

    Y

    12" MIN.

    PREPARE PLANTING SOIL

    SEE PLANTING PLANS AND

    PLANT LIST FOR SPACING

    NOTE: FOR CONTAINER STOCK,

    PULL POTTING MIX AND ROOT MAT APART

    TO DIRECT THE OUTER ROOTS INTO ADJACENT SOIL.

    DO NOT LEAVE CIRCLING ROOTS AGAINST ROOT BALL

    FINISH GRADE

    PLACE TOP 1/8 OF ROOT BALL ABOVE FINISH GRADE

    CUT ROPE FROM TOP OF ROOT BALL & TURN

    BACK BURLAP FROM TOP 1/3 OF ROOT BALL

    1" SHREDDED, COMPOSTED PINE BARK MULCH

    PLANTING SOIL PREPARED AS SPECIFIED.

    TAMP AND WATER WHEN BACKFILLING AROUND PLANT

    EXISTING PICKET GATE

    EXISTING PICKET FENCING EXISTING SCREEN BORDER FENCING

    1

    12

    2" DIA. SCH. 40 PVC PIPE FOR

    WEEPHOLES, 8' O.C., RECESS

    BACK 2" FROM FACE OF WALL.

    LEAVE 1-1/4" GAP BETWEEN

    STONES IN FACE OF WALL FOR

    OUTFLOW.

    COMPACTED SUBGRADE TO 95%

    DENSITY

    2" MAX. DIA. DRAINAGE

    AGGREGATE CONTINUOUS ALONG

    BACK OF WALL. WRAP IN FILTER

    FABRIC (MIRAFI 140N) - OVERLAP

    JOINTS

    CARDEROCK STONE TO MATCH EXISTING

    WALLS

    TOP STONES NOT LESS THAN 6"

    THICK RANGING FROM 12" TO 30"

    IN LENGTH - FLUSH MORTAR

    JOINTS ON TOP SURFACE

    6"

    2"

    1'-2"

    24"

    PERENNIAL AND

    GROUND COVER

    PLANTING

    3'-0"

    MA

    X.

    1'-2"

    EX STONE WALL

    STONE KNEE WALL

    C1" = 1'-0"

    STONE TO BE CARDEROCK STONE BLEND: ±60%

    CARDEROCK PREMIUM SNAPPED VENEER, ±40%

    CARDEROCK LARGE BROWN VENEER, CONTRACTOR TO

    PROVIDE SAMPLE TO BE APPROVED BY CLIENT AND C&A

    PRIOR TO INSTALLATION

    UNDISTURBED SUBGRADE AT 98% COMPACTION

    24" MIN.

    BELOW

    GRADE

    ADJACENT

    PAVING

    18"

    PLANTING

    1'-0"

    1'-6"

    CONCRETE FOOTING

    2'-6" M

    IN

    .

    FILL COMPACTED TO 95% UNDER ENTIRE

    STAIR, FOOTINGS, AND SLAB

    1

    1

    2

    " TYP.

    12" MIN.

    12" MIN.

    ADJACENT CONDITION, VARIES

    #4 @ 12" O.C. EACH WAY (TYP.) AND

    AT NOSE OF EACH STEP

    2" THICK NATURAL STONE TREADS WITH THERMAL

    FINISH AT EXPOSED EDGES. SET RISER AND TREAD

    STONE IN 5/8" MORTAR SETTING BED.

    6"

    1'-2"

    STONE CHEEK WALL BEHIND STAIR

    HANDRAIL, AS REQUIRED, SEE SITE

    PLAN FOR LOCATIONS

    #4 DOWELS

    @8" O.C. (TYP.)

    CARDEROCK STONE RISER TO MATCH WALL

    STONE; NO VISIBLE MORTAR JOINTS; MORTAR

    COLOR SHALL MATCH STONE

    BLUESTONE PAVING

    26