22
R. Bertini – PQE Group August, 2018 III All-Russian GMP conference A practical approach to Data Integrity Assessment and CAPA Plan

III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

R. Bertini – PQE Group August, 2018

III All-Russian GMP conference

A practical approach to Data Integrity Assessment and CAPA Plan

Page 2: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

REGULATORY BACKGROUND• Data integrity shall be embedded in the Pharmaceutical Quality

System to ensure:

Man

ufac

turin

gR

esea

rch

Vigi

lanc

e on

Fi

nal

Prod

uct

QUALITY OF MEDICINES

QUALITY OF GXP DECISIONS

Page 3: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

EVOLUTION OF GMP PROCESSES• 1997 2018

Use of Computer Systems and Electronic Records in Lab and Prod processes has greatly increased in the last 20 yearsDI Compliance is nowadays a fundamental requirement for Lab and Prod Systems

Page 4: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

DATA INTEGRITY REQUIREMENTS

• Attributable & Consistent, e.g. User Access Control

• Legible & Enduring. e.g. Backup in place

• Contemporaneous, e.g. Secured Timestamp

• Original, e.g. secured Audit Trail

• Accurate & Available, e.g. User groups, Trainings, Computerized Systems Validation

GxP

DATA INTEGRITY: The extent to which all data are complete, consistent and accurate throughout the data lifecycle, i.e. from initial data generation and recording through processing (including transformation or migration), use, retention, archiving, retrieval and destruction.In a nutshell: GxP records are required to be ALCOA+

Page 5: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

TUNE THE ASSESSMENT LEVEL

Level of details and relevant expected outcomes should be tuned on the basis of the agreed resources in terms of time, acceptable regulatory exposure and budget

Exposure

Budget

Time

Assessment activities may be developed combining one or more keyfactors (see below):o Status of Technology used to implement data integrity featureso Adequacy and Completeness of Data/Systems Validation Life Cycleso Presence of specific Process/Operational requirements within

specifications and testing documentso Status of supporting Quality System documentso Status of IT Infrastructure Qualification supporting GxP critical applications

Page 6: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

PROPOSED METHODOLOGYBased on best practices, developed and fine-tuned in +500assessment projects with regulated companies world-wideTakes into account:o Applicable regulatory requirementso most recent guidelines on DI issued by Regulatory Authorities world-wideo feedback from authorities inspections

It is intended to be used:o When it is necessary to deal with a high number of systems in a short timeo to quickly identify the most common DI gaps in a system and immediately start the

remediated phaseStreamlined assessment phaseRisk-based and priority–driven approach to the remediation phase

Page 7: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

ASSESSMENT METHODOLOGY

SYSTEMS INVENTORY

SYSTEMS RISK ASSESSMENT

SYSTEMS GAP ANALYSIS • TECHNOLOGY • DOCUMENTATION

CAPA PLAN

CAPA PLAN EXECUTION

3

4

1

5

2

Page 8: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

1 – Inventory

• Unique System ID• Business Unit/Department• Location• Control SW Name• SW Version• SW Supplier

• HW / Controlled Equipment ID • HW / Controlled Equipment description• Business Process Owner• Technical Owner (System Administrator)• Quality Unit• Interfaced systems

SYSTEM INFORMATION

• GxP Relevance• Regulated ER/ES• System Risk Priority Level • System GAMP Category• Notes

ANALYSIS RESULT

GxP Relevance Regulated Regulated ERES

Relevance System Risk

Level

System GAMP

Category(Yes/No) ER ES (Yes/No) (VH, H,M,L) (1,3,4,5)

PCS.001 Pharma 5 Pharma 5 EBRS 3.0/21 Werum Körber Solutions NA Chargendokumentation

Fermentation/ Aufarbeitung XXX YYY ZZZ Yes Yes

-Master Batch Record-Batch Record-Measurement values (PCS)-Messages (PCS)-weighing values

all manual process stepts

Yes VERY HIGH 5Configurations:- Material Master- Batch Master

PCS.002 Pharma 5 120 ABB WUPWP07-P002 5.1 ABB NA Aufarbeitung XXX YYY ZZZ Yes Yes

-Alarms History-Control Recipes (batch specific)-Sequences-Trends-Messstellen-Alarm Tresholds-Set Points

NA Yes High 5

PCS Aufarbeitung including:- Server (Windows Server 2008)- OS Operative Panels (Windows 7 embedded [Thin Clients])- Controllers

808xA (Handling SW)TCL Builder (Recipts) - MOD 300Contol Builder (Messstellen) MOD 300IMS interface to EBRS

Master Recipe is a SW application developed inside the System (GAMP SW 5). The system is provided with a tool for source code compare

PCS.005_a Pharma 5 120 ChemStation LC B04.03-SP1

[87]Agilent

Technologies HPLC86

- HPLC86 (Agilent Technologies 1200 Series) TCC + Gerstel Multipurpose Sampler MPS3+J17

XXX YYY ZZZ Yes Yes

- Instrument Methods- Methods. Sequences- Raw Data- Results/Report

No Yes Medium 4

Server HDEWUPS0237Interface between PLS ABB WUPWP07-P002 und Online HPLC-Systemen HDEWUPC8342, HDEWUPC8343 und HDEWUPC9055Notes of process on notebookInstrument Methods and Methods are connected (stored on the same file)Process Owner is Pharma 5 but the system is shared with Q and it's also located into Q laboratory. The system was assessed from the Pharma 5 process point of view.

NotesQuality Unit

Business Unit / Department Location Control SW Name SW Version SW Supplier

HW / Controlled

Equipment ID

HW / Controlled Equipment Description

Business Process Owner

Technical Owner

SYSTEM INFORMATION RISK ANALYSIS RESULTS

Interfaced System

(Yes/No)

System ID (Sort field)

From PIC/S Guidance “Good Practices for Computerized Systems in Regulated GxPEnvironments”

OPERATING ENVIRONMENTCOMPUTERIZED SYSTEM

PROCESS

INFRASTRUCTURE (NETWORK)

COMPUTER SYSTEM(Controlling System)

SOFTWARE

HARDWAREFIRMWARE

CONTROLLED FUNCTION

OPERATING PROCEDURES AND

PEOPLE

EQUIPMENT

Page 9: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

2 – System Risk Assessment

CRITICALITY

COMPLEXITY

System Risk Level is determinedbased on the combined values ofCriticality and Complexity

CRITICALITY

HIGH MEDIUM LOW

COM

PLEX

ITY

HIG

H

HIGH

MED

IUM

MEDIUM

LOW LOW

Impact of Systems andrelated E-records onpatient safety and productquality

Degree to which data canbe configured, andtherefore potentiallymanipulated

SYSTEM RISK LEVEL

Predefined checklists are used to evaluate the Criticality and Complexity of each System

Page 10: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

3 – GAP Analysis: Technology

The Technology Gap Analysis is oriented to verify whether adequate featuresresult to be in place, in order to meet all data integrity requirements

Access Control User Profiles Audit Trail Protection from Records Alteration

Time Reference Backup / Restore Auto Save E-signature

Page 11: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

3 - GAP Analysis: DocumentationSystems life cycle should be developed to embed data integrity measures following quality-by-design approach. Systems Validation Life Cycles is assessed to verify the Adequacy andCompleteness of implemented strategy/approaches and life cycle documents

Validation Life Cycle Operation & Administration Procedures

SOP

Page 12: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

3 - GAP Analysis: System Compliance Level

Results of GAP Analysis are recorded and evaluated in dedicated work-sheets

SEVERITY OF TECHNOLOGY GAPS

NULL LOW MEDIUM HIGH

SEVE

RITY

OF

DOCU

MEN

TATI

ON

GAP

S

NU

LL FULL

LOW PARTIAL

MED

IUM

LOW

HIG

H

NO

System Compliance Level is determined based on the combined values ofTechnology and Documentation Gaps Severity

TECHNOLOGY ASSESSMENT

DOCUMENTATION ASSESSMENT

Page 13: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

4 – CAPA Plan: Regulatory ExposureSystem Regulatory Exposure is determined based on the combined values of ComplianceLevel and Risk Level

Priority and Timing of CAPA execution shall be based on the Regulatory Exposure

SYSTEM COMPLIACE LEVEL

NO LOW PARTIAL

SYST

EM R

ISK

LEVE

L HIG

H

HIGH

MED

IUM

MEDIUM

LOW LOW

SYSTEM COMPLIANCELEVEL

SYSTEM RISK LEVEL

REGULATORY EXPOSURE

Page 14: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

Assessment Summary ReportGxP

Relevance Regulated Regulated ERES Relevance

System Risk Level

System GAMP

Category(Yes/No) ER ES (Yes/No) (VH, H,M,L) (1,3,4,5)

PCS.001 Pharma 5 Pharma 5 EBRS 3.0/21 Werum Körber Solutions NA Chargendokumentation

Fermentation/ Aufarbeitung XXX YYY ZZZ Yes Yes

-Master Batch Record-Batch Record-Measurement values (PCS)-Messages (PCS)-weighing values

all manual process stepts

Yes VERY HIGH 5Configurations:- Material Master- Batch Master

PCS.002 Pharma 5 120 ABB WUPWP07-P002 5.1 ABB NA Aufarbeitung XXX YYY ZZZ Yes Yes

-Alarms History-Control Recipes (batch specific)-Sequences-Trends-Messstellen-Alarm Tresholds-Set Points

NA Yes High 5

PCS Aufarbeitung including:- Server (Windows Server 2008)- OS Operative Panels (Windows 7 embedded [Thin Clients])- Controllers

808xA (Handling SW)TCL Builder (Recipts) - MOD 300Contol Builder (Messstellen) MOD 300IMS interface to EBRS

Master Recipe is a SW application developed inside the System (GAMP SW 5). The system is provided with a tool for source code compare

PCS.005_a Pharma 5 120 ChemStation LC B04.03-SP1

[87]Agilent

Technologies HPLC86

- HPLC86 (Agilent Technologies 1200 Series) TCC + Gerstel Multipurpose Sampler MPS3+J17

XXX YYY ZZZ Yes Yes

- Instrument Methods- Methods. Sequences- Raw Data- Results/Report

No Yes Medium 4

Server HDEWUPS0237Interface between PLS ABB WUPWP07-P002 und Online HPLC-Systemen HDEWUPC8342, HDEWUPC8343 und HDEWUPC9055Notes of process on notebookInstrument Methods and Methods are connected (stored on the same file)Process Owner is Pharma 5 but the system is shared with Q and it's also located into Q laboratory. The system was assessed from the Pharma 5 process point of view.

NotesQuality Unit

Business Unit / Department Location Control SW Name SW Version SW Supplier

HW / Controlled

Equipment ID

HW / Controlled Equipment Description

Business Process Owner

Technical Owner

SYSTEM INFORMATION RISK ANALYSIS RESULTS

Interfaced System

(Yes/No)

System ID (Sort field)

ICO

S LS

T80

Seav

isio

n Te

rmof

orm

atric

e K2

60/1

Fede

gari

AU 8

524

Them

a 4

Fede

gari

AU 8

525

Them

a 4

Auto

clav

e M

aste

r 6 D

e La

ma

AU00

9

Sper

latri

ce a

utom

atic

a tu

bofia

le B

reve

tti C

ea A

TM

32+/

DSW

Ope

raPa

lltro

nic

Flow

star

FFS

XC

mat

ricol

a 14

1535

26

Pallt

roni

c Fl

owst

ar F

FSXC

m

atric

ola

1714

6626

Pallt

roni

c Fl

owst

ar F

FSXC

m

atric

ola

0431

0026

+

AQUA

VIT

tipo

AW02

XC

mat

ricol

a 17

0359

28

Com

pute

r Sys

tem

Ope

ra

ATM

2x8

Bila

ncia

pes

apez

zi m

odel

lo

Tecn

oEur

opa

Line

a k2

60 -

2Ite

m B

I001

Etic

hetta

trice

EF/

20 C

ORI

MA

Item

IT00

2

Mac

chin

a as

sem

blat

rice

Item

Y00

2 (S

W M

asm

ec)

84, 87, 88 141 1234 125 430 420 123 123 123 146, 147, 148

146, 147, 148

146, 147, 148

146, 147, 148

PCS_007 PCS_037 PCS_009 PCS_010 PCS_011 PCS_012 PCS_013 PCS_014 PCS_015 PCS_016 PCS_017 PCS_018 PCS_019

H M L L L L L L L L L L L

LOW Short TermMEDIUM Medium Term

HIGH Long Term

FD-05 Access control available but not activated

Security11.10 (d,g),

11.300 (a)

12.112.212.3

x RA6: Implement unique and personal accounts for the SW application

FD-06

Secondary security features (expiry date, minimum lenght, automatic log off) are available but not correctly configured or not activated

Security11.10 (d,g),

11.300 (a)

12.112.212.3

xRA7: Issue a Security SOP regulating a manual or hybrid management of secondary security features.

RA8: Configure secondary security features according to relevant SOP and good practices.

FD-07User list and related privileges is either not available or not updated

Security11.10 (d,g),

11.300 (a)

12.112.212.3

RA9: Implement a user list or update the existing one

FD-08

Roles and privileges conflicts exist since Administrators have multiple accounts including analysts one

Security11.10 (d,g),

11.300 (a)

12.112.212.3

x xRA10: Review user accounts and make sure administrators of the SW application do not have analyst privileges and analyst accounts

FD-09 A backup process is not in place Integrity 11.10 (c)

7.217 x x x

RA11: Execute and document manual backups of system data with a regular frequency (daily/weekly) to be defined in a dedicated procedure

RA12: Implement a process of automatic, daily backup following a relevant procedure and best practiceRA13: Execute and document restore procedure of system data with a regular frequency to be defined in a dedicated procedure

Remediation Actions

Regulatory Exposure = Solved

(i.e.fully compliant solution after the implementation of the corrective action)

Within February 2017

Regulatory Exposure = Mitigated

(i.e.residual Regulatory risks may hold after the implementation of

the corrective action)

For each GAP at least one Remediation action either solving or mitigating is due to be implemented. Immediate implementation of a solving solution

makes un-necessary the presence of mitigation also. SW Upgrade actions will be implemented within 2018

Find

ing

ID

Finding Description Topic

21

CFR

Par

t 11

Ref

eren

ce

Ann

ex 1

1 R

efer

ence

ImpactSystem Risk Level

PriorityWithin July 2016

Within November

SHORT TERM

MEDIUM TERM

LONG TERM

Page 15: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

5 – CAPA Plan ExecutionAccess ControlSoDBackup & ArchivingAudit TrailData ProtectionTime Reference Protection

Lack of CSVLack of Procedures

MOST COMMON GAPS

Solve the observed GAPs (Enhance SW features, CSV, SOPs) and.......if a lack of control measures has been observed during the assessment… Solution of observed gaps (e.g.activating audit trail functions and instituting password controls) could be insufficient to address possiblemanipulations of data occurred in the past

Page 16: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

CAPA - How To Meet Regulatory ExpectationsCAPA Plan should address control measures for historical data and for observed gaps

CAPA FOR HISTORICAL DATA CAPA FOR OBSERVED GAPS

Assess Historical Data in case the current status is observed as deficient

Reliable Data

Data integrity technical measures

SOPs & CSV to ensure system reliability

Page 17: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

CAPA - Historical Data Review

VERIFY TRACE TO SOURCE DATA FOR

EACH STEP

CERTIFICATE OF ANALYSIS

ANALYTICALMETHOD

VALIDATION

RAW DATA

DATA ELABORATION

RESULTS

PAPER LAB NOTEBOOK OUT OF

SPECS

LAB INVESTIGATION

REPORT

INSTRUMENTQUALIFICATION

COMPUTER SYSTEM

VALIDATION

REFERENCE STANDARDS

OPERATORS TRAINING

PRODUCT SPECIFICATIONS

INSTRUMENT

ANALYTICALMETHOD

RESULTS DEMONSTRATING PRODUCT QUALITY RELY UPON

THE ENTIRE CHAIN OF RECORDS

Page 18: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

Sample Based Approach For Data ReviewRisk based sampling plans can be defined to identify a sample of selected batches to bereviewed

Zero Acceptance NumberSampling Plans - Fifth Edition

DATE Bacth Number (Bx) 2776 Bacth Number (Bx) Bacth Number (Bx) Bacth Number (Bx)

Process (Px) Sterilization Process (Px) Process (Px) Process (Px)

EQUIPMENT Recipe (Rx) Proram 12 Recipe (Rx) Recipe (Rx) Recipe (Rx)

PROCESS ID ACTION DESCRIPTION ACCEPTANCE CRITERIAPAPERS DOCUMENT TO BE CHECKED

VERIFICATION RESULT(ACCEPTANCE CRITERIA

MET)

NOTES/REFERENCES or

SPECIFICATIONS

VERIFICATION RESULT(ACCEPTANCE CRITERIA

MET)

NOTES/REFERENCES or

SPECIFICATIONS

VERIFICATION RESULT(ACCEPTANCE CRITERIA

MET)

NOTES/REFERENCES or

SPECIFICATIONS

VERIFICATION RESULT(ACCEPTANCE CRITERIA

MET)

NOTES/REFERENCES or

SPECIFICATIONS

CRITICAL PARAMETERS R01Are critical parameters recorded on the system and used for the process execution the same as reported in the relevant paper document?

Yes.Process parameters stored in the system match the values reported in the paper document

- Batch Record [X]-Master Batch record [X]- Equipment Logbook [ ]- Process Validation [ ]- Users Training [ ]

RECIPES R02Are Recipes used for the process execution the same as reported in the relevant paper document?

Yes.Recipes stored in the system match with recipes reported in the paper document

- Batch Record [X]-Master Batch record [X]- Equipment Logbook [ ]- Process Validation [ ]- Users Training [ ]

PROCESS EXECUTION R03Are Batch Data saved on the system the same as reported in the relevant process phase of paper document?

Batch Data related to the process execution (process results) are the same as reported in the paper document

- Batch Record [X ]- Equipment Logbook [ ]- Process Validation [ ]- Users Training [ ]

PROCESS OPERATOR R04Are Users configured on system consistent with the Users reported in the relevant paper document?

Users configured on system are consistent with those reported in the relevant paper document

- Batch Record [ ]- Equipment Logbook []- Process Validation [ ]- Users Training [X]- Users List [X]

PROCESS OPERATOR R05

Check the consistency between operations/Users recorded on the Bacth Record and operations/Users traced in the Audit Trail (if available)

Operations executed on system match with the Audit Trail record

- Batch Record [X]- Equipment Logbook [ ]- Process Validation [ ]- Users Training [ ]

PROCESS OPERATOR R06

Check the consistency between operations/Users recorded on the Bacth Record and operations/Users traced in the relevant paper document (if Audit Trail is not available)

Operations executed by Users on system match with the relevant paper document

- Batch Record [X]- Equipment Logbook [X]- Process Validation [ ]- Users Training [ ]

PROCESS VALIDATION R07Are critical parameters used for the process execution within the tolerance values verified during the Process Validation (PQ)?

Critical parameters used for the process execution are within the tolerance values verified during the Process Validation (PQ)

- Batch Record [ ]- Equipment Logbook [ ]- Process Validation [X]- Users Training [ ]

REPORT TIMESTAMP R08Are Date and Time of process Results saved on system consistent with those reported in the relevant paper document?

Date and Time saved on system are consistent with those reported in the relevant paper document

- Batch Record [X]- Equipment Logbook [ ]- Process Validation [ ]- Users Training [ ]

DOCUMENT ID

SYSTEM

SAMPLE DATA #3 SAMPLE DATA #4

COMPANY

ACCESS CONTROL & GENERIC USERS ASSESSMENT RESULTS: MITIGATION ACTIONS AND RETROSPECTIVE REVIEW SUMMARY PLAN

SAMPLE DATA #1 SAMPLE DATA #2

Cross Check of information available on Paper and Electronic Records

Page 19: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

CAPA – Solution of Observed (Technology) GapsSystem specific solutions depend on IT scenario boundary conditions

IT Architecture: Stand-alone vs Client-ServerConnection to Domain Network (for stand alone)SW Infrastructure (e.g. Operating Systems)SW Applications

Configure restrictions/policies of SW Application and/or Operating System

Install and configure externalSW Tools (mirroring, security, back-up)

Paper-based work-aroundfor Interim Mitigation

System Replacement / Upgrade of SW application release

Page 20: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

CAPA – Solution of Observed (Documentation) GAPsValidation Life-Cyle for Systems managing Regulated Electronic Records

DOCUMENTED EVIDENCE OF COMPLIANCE

Page 21: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

Conclusions

“It takes something more than intelligence to act intelligently”

Фёдор ДостоевскийПреступление и наказание

Page 22: III All-Russian GMP conference A practical approach to ...gosgmp.ru/download/Materialy/Den_3/MK_3/GMP_eng... · In a nutshell: GxP records are required to be ALCOA+. ... 11.300 (a)

Acknowledgements

www.pqegroup.com

[email protected]