Impact Assessment Report
Prime Industrial LED Signage
Property:
Lot 101, #69 Craigie Street, Davenport
Date: February 2017
Prepared by: Gary Fitzgerald
2
Background and Summary
The purpose and intent of the City’s Local Planning Policy relating to Advertising Devices (LPP) is to
control and guide the development of signage and advertisements on zoned land in order to safeguard
and enhance the character and amenity of the built and natural environment of the Local Planning Policy
Area.
The City’s Local Planning Policy seeks to ensure that signage and advertisements are treated as an
essential component of development.
In accordance with the LPP the stated objectives of the City’s LPP are as follows:
3
The LPP uses a Code Based approach utilising a nationally accepted practice of setting out
Performance Criteria and Deemed to Satisfy solutions. A performance based model allows flexibility to
determine compliance either through Deemed to comply or Performance criteria.
Part D Variation of Development Requirements of the Signage Local Law states:
Development in accordance with this LPP is deemed to comply. However alternative designs may be
considered subject to demonstration that he proposed land use and /or development is in keeping with
the intent and objectives of this LPP to the satisfaction of the local Government.
The policy states that in exercising discretion the local government should ensure the variation will not
contravene the following provisions of the scheme-
Purpose
The purpose of the Development Impact Statement is to allow for an applicant to demonstrate that a
signage application while not complying specifically with the Deemed to Comply provisions meets the
Performance criteria of the LPP.
Assessment
Prime Supplies is an independent locally owned business established in 2008 providing services to a
range of local and regional businesses. Prime pride itself on providing a range of services and stock
over 19,000 product lines on it shelves. The family owned local business is a major employer in the City
and employs over 25 people.
The owners of Prime Industries are proposing to construct an Electronic Graphic Display Screen on the
frontage or Western elevation of the existing building. The proposed signage was originally proposed
at over 60m2 however after discussions with the Council planning staff it was identified that a reduction
in the size of the sign would be more in keeping with the intent of the City’s LPP the applicant has
reduced the size of the sign to 50m2. Which equates to an area of only 4.8% of the site. A copy of the
plans detailing the signage is attached at appendix 1
With such a diverse range of services the owners have identified the need to provide signage that
effectively promotes the products and services they provide. The owners have also identified that the
effectiveness of large static signage is less than desirable for the nature and diversity of their business.
Prime industries is located on Lot 101 No 69 Craigie Street. The lot is 11466m2 in area and is zoned
Industry under the City’s operative Town Planning Scheme No 7. The building is setback 15 m from the
front boundary and in regards to the setback from road the building is setback over 50m from the nearest
intersection.
4
In addition to the setback the property is screened from Southwest highway by a dense landscaped
road reserve which provides a buffer between South West Highway road and the building. The front of
the property has a significant grassed/ landscaped verge maintained by the owners of the property.
The City’s LPP refers to the maximum area of signage on a Primary Street frontage as being calculated
with a formula of Frontage of the Lot, plus 10, divided by 2. In regards to the subject site this equates
to the following
Frontage 90m + 10 = 100 / 2 = 50m2 maximum area of signage allowed
Standard Design Requirements
The deemed to comply requirements for an Electronic Graphic Display Screen refer to the maximum
size of the sign on a single facade of 20m2. The proposed sign is 50 m2 therefore the applicant is
seeking approval through the Performance based approach or Impact assessment determination.
In justifying the signage the following points are noted:
• The use of LED Graphic Signage is becoming a far more utilised type of signage which provides
an attractive vibrant and effective mechanism for businesses to advertise. The technology
advances will see this type of signage becoming an integral part of many business operations.
• While the sign is larger in area than 20m2 it is argued that the size of the building, its setback
and location as well as the nature of the business , justify the marginal increase in size.
• The applicant does not propose a proliferation of other signage on the site, other than effective
discrete way finding signage. This ensures that the development inclusive of the signage
presents as a modern contemporary development which adds to the amenity of the existing
streetscape and the vibrancy of the area generally.
• The signage is well separated from any roads/ intersections and is also screened by the road
reserve vegetation buffer.
• The proposed signage is not intrusive on the existing/ surrounding built environment and the
luminance levels proposed will not impact on road users or surrounding land owners.
• The proposed sign will comply with the LPP requirements in regards to animated and digital
format and will only display static messages in either text or pictographic format.
• Messages will change instantaneously and have no blank screen between messages. The
duration of transition between the full display of one message and the full display of the next
message will not exceed 0.1 seconds. The sign will not display animated or digital format.
• The level of illumination and location to major road intersections is considered to be less
conflicting than similar LED signage approved elsewhere in the City.
The owners have sought comment from a LED signage supplier in regards to the luminance levels. The
following is a summary of comments provided:
The signage luminance will maintain minimum static periods as per the LPP requirements.
The City’s requirements for an outdoor LED screen will not be effective if maintained at levels
prescribed.
To be effective, luminance levels need to be varied according to conditions for example in bright sunlight
luminance levels need to be increased in overcast or at night the levels can be decreased. Issues that
need to be considered are for example other lighting sources.
It is suggested that a more appropriate and effective measure would be light measurement readings
from given parameters ( e.g. a distance from the LED screen) The luminance measurement of a LED
screen can be measured with and be specified for particular conditions without having a singular
reference which will not be effective or relevant in all conditions it is recommended that a more accurate
5
measurement would be that the output is managed so that the cd ( Candela , which s luminous intensity)
reading would not exceed a given specification cross a range of conditions that the screen is operating.
The proposed screen is 9m above ground and 12m at the top. From a given distance, this is not going
to provide the same candela reading as the same screen located 1 m above the ground at the same
distance.
Road Safety Audit
The City’s LPP for Signage refers to the possibility of the requirement for a road safety audit being
undertaken where the following is applicable:
Located within 50m of traffic signals or road intersection and / or visible from within 50m of traffic signals
or road intersection
It is clear that the location of the illuminated signage is not within any of the specified distances as
referred in the LPP for consideration of a Road Safety Audit. Furthermore the road reserve vegetation
strip provides further screening of the signage from the nearest road intersection.
Distances from Intersections
View shed Analysis
In accordance with the provisions of the LPP a visual impact assessment has been undertaken
analysing the proposed location, type and design of signage and its impacts on the landscape character
and visual amenity with particular reference to the following:
• Surrounding Buildings
• Affected Residential premises.
• Impact on Road Network and Road Users
A view shed analysis has been undertaken and viewpoints are attached at appendix 2
6
The viewpoints analysed are from the entry into the city form a southern direction indicating impact from
entry into the City via South West Highway. A view point from the north of the site reflecting the view
from Roberts Drive and view point from the Western side of the property or directly in front of the
property taken from the intersection of Halifax and South west Highway.
These view points while analysed are not considered to be major public view points of noted significance
however as a major entry into the City an analysis of the impact has been undertaken.
As can be seen by the photographs in appendix 2 the building is in keeping with the scale and type of
development in the area and the addition of the illuminated signage will not be a dominating aspect on
either the streetscape or any views of significance. The setback and the mature landscaped buffer on
the South West Highway Road Reserve provides an effective and attractive barrier / separation and
significantly reduces any impact on any viewpoints.
The proposed signage has significant positive implications on the surrounding properties and the area
generally. Creating a vibrant and attractive façade to the building. The surrounding landowners are
supportive of the proposed signage and perceive the proposal as a positive contribution to the area.
Comments from surrounding land owners are attached at appendix 3
Lumination of the immediate area will support the principals of Crime Prevention through Environmental
Design (CPTED). Of high consideration to the applicant is to ensure that there are no impacts
associated with any light spill on adjoining land.
It is argued that illuminated signage is not only more effective for the business but provides other
advantages such as enhancing driver safety by ensuring that signage is clearly legible and easily
recognisable to drivers. This is balanced by ensuring appropriate illumination levels that operate with
consideration to both day time and night time operation.
Conclusion
The proposed signage is marginally larger than the maximum area specified for an Electronic Graphic
Display Screen as prescribed in the Deemed to Comply provisions of the City’s LPP however the
maximum area of signage is compliant with the LPP in regards to the maximum area of 50m 2 as per
the LPP requirements for the lot.
Importantly the size of the signage is in keeping with the scale , design and nature of the building and
is setback a considerable distance from the Primary Street. The signage does not impact on the road
network and is separated by distances compliant with the LPP to ensure that there is no percieved
negative impact on road uses.
The site is screened by natural vegetation buffer of mature trees in the South west Highway Road
Reserve and as demonstrrated in the view shed analysis there are no views of significance that are
affected. In fact the addition of the development including the signage is a positive addition to the area
increasing the amenity of the area generally and improving the existing streetscape.
It is clearly demonstrated that the proposed signage complies with the City’s and Main Road
considerations for LED signage and as such there is no need to undertake any further analysis or
advertising.
The proposal is supported by the surrounding land owners who welcome the development generally
and the signage as proposeed.
The City’s LPP identifys the ability to approve signage on a Performance Based approach and it is
clearly demonstrated that the proposal meets the objectives of the City’s LPP. The applicant urges the
City to support their proposal.
7.00°7.00°
CRAIGIE STREET
PARAPET WALL (CONCRETE)PARAPET WALL (CONCRETE)PARAPET WALL (CONCRETE)PARAPET WALL (CONCRETE)
EXISTING TRIMDECK ROOF SHEETING
EXISTING T
RIMDECK R
OOF
SHEETING (@ L
OWER L
EVEL)
EXISTING TRIMDECK ROOF
SHEETING (@ LOWER LEVEL)
EXISTING TRIMDECK ROOF SHEETING
7.00°
7.00°
7.00°
7.00°
7.00°
5.0
0°
5.0
0° 4.50° 4.50°
C/BOND (SURFMIST) TRIMDECK ROOF SHEETING
C/BOND (SURFMIST) TRIMDECK
ROOF SHEETING
1037
18250
3500
PROPOSED W
ESTERN 'LED' SIGN
DATEPROJECT NO.
DRAWING NUMBER. Rev.
DRAWING
ADDRESS
CLIENT
PROJECT
©
DRAWN BYDESIGNED BY
A11. THIS DRAWING IS COPYRIGHT PROTECTED AND REMAINS THE PROPERTY OF MERGE BUILDING
DESIGN (ABN 25 048 357 461) AND SHALL NOT BE USED FOR ANY OTHER PURPOSE THAN
ORIGINALLY INTENDED
2. READ FIGURED DIMENSIONS IN PREFERENCE TO SCALE. ALL DIMENSIONS IN mm U.O.N.
3. BUILDER TO CHECK AND CONFIRM ALL MEASUREMENTS, LEVELS & DETAILS PRIOR TO THE
COMMENCEMENT OF ANY WORK OR FINANCIAL COMMITMENT. BUILDER TO CHECK AND CONFIRM
MEASUREMENTS OF EXISTING BUILDING
4. THIS DRAWING TO BE READ IN CONJUNCTION WITH ALL BUILDING DESIGN DRAWINGS,
ARCHITECTURAL NATSPEC SPECIFICATION, ALL CONSULTANTS DRAWINGS AND SPECIFICATIONS &
MANUFACTURERS SPECIFICATIONS
5. ALL WORKSMANSHIP AND MATERIALS TO BE IN ACCORDANCE WITH THE MOST CURRENT
BUILDING REGULATIONS, S.A.A. CODES AND AUST. STANDARDS
PHONE: (08) 97 215 300 FAX: (08) 97 215 800
EMAIL: [email protected]
MAIL: PO BOX 406, Bunbury, WA, 6231
WEB: www.mergedesign.com.au
10/01/2017 3:12:06 PM
AALOT 101 (#69) CRAIGIE ST, BUNBURY
1525
C02
ADDITIONS AND RENOVATIONS TO EXISTING
INDUSTRIAL BUILDING
PRIME INDUSTRIAL
EXTERIOR LED SIGNAGE
AGMASTERSL SL
REVISION SCHEDULE
REV. DATE DESCRIPTION
AA 10-1-2017 RE-ISSUED FOR SIGNAGE
1 : 200SK08
ROOF PLAN - LED SIGNAGE1
EXTERIOR 'LED' SIGNAGE
2700
3600
2700
3600
24002400
900
2100
3600
2700
3600
2700
3600
2700
3600
2000
2700
1000
2700
2700
1300
2000
25002600
EXIST. KNEE HEIGHT
FFL 00
SHOWROOM CL
MEZZANINE FFL
FHRFHR
7150
1300
3600
EXIST. RIDGE
260
8450
260
NEW SHOWROOM/OFFICE
8970
1111
8450
3600
8850
F
LLLL
SFSF
WALL MOUNTED 'LED' ADVERTISING
SCREEN. SUPPORTING STRUCTURE
AND SCREEN BY OTHERS
2800
400
LED S
IGN
LED SIGN
JAMES HARDIE 1200 x 3000 9mm EXOTEC PANELS (ON JH 35mm
BATTEN) WITH 10mm EXPRESSED JOINTS TO FORM FEATURE FIN
PROTRUSIONS INSTALLED AS PER MANUFACTURERS SPECIFICATIONS
PAINT FINISH. COLOUR: PAINT A
CONCRETE TILT PANEL
BEYOND WITH PAINT
FINISH. COLOUR: PAINT B
3200
5650
STEEL LOUVRE BLADE SCREEN STRUCTURE
WITH POWDER COAT FINISH. COLOUR:
C/BOND 'SURFMIST'
CONCRETE TILT PANEL BEYOND WITH
PAINT FINISH. COLOUR: PAINT B
PRECAST CONCRETE AWNING PANEL
WITH PAINT FINISH. COLOUR: PAINT A
ALUMINIUM FRAMED SHOP FRONT WINDOWS
WITH MIN. 6.38mm LAMINATED GLASS. ENERGY
RATING AS PER 'THE STUDY' REPORT
103718250 3500
9250
2750
LOUVRE WINDOWS BEHIND
FIRE ESCAPE DOOR CUT IN TO
EXISTING PURLINS/CLADDING
EXISTING ROOF
SHEETING
NEW SHOWROOM/OFFICE
EXISTING EXISTING
3200
WEST ELEVATION TOTAL AREA: 1021m²
PROPOSED LED SIGNAGE AREA: 50m²
% OF ELEVATION WITH SIGN: 4.8%
12000
EXIST. KNEE HEIGHT
FFL 00
SHOWROOM CL
MEZZANINE FFL
MEZZ. OFFICE CL
EXIST. RIDGE
1200 10 1200 10 120010
1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 402
NEW SHOWROOM/OFFICE
100
1200
102400
102470
102700
CFC P
ANEL
SPACINGS
CFC PANEL
SPACINGS
300 FIN
3150
1300
2700
1300
3600
1111
8450
3600
L F F L F F L F FLLL
L F FL
FFF
WINDOWS BEHIND
LYSAGHT LONGLINE 305 STEEL CLADDING INSTALLED AS
MANUFACTURERS SPECIFICATIONS OVER CONCRETE TILT
PANELS. C/BOND FINISH: C/BOND 'SURFMIST'
JAMES HARDIE 1200 x (VARYING LENGTH) 9mm EXOTEC PANELS (ON JH
35mm BATTEN) WITH 10mm EXPRESSED JOINTS INSTALLED AS PER
MANUFACTURERS SPECIFICATIONS PAINT FINISH. COLOUR: PAINT A
STEEL COLUMN & STEEL LOUVRE BLADE
SCREEN STRUCTURE WITH POWDER COAT
FINISH. COLOUR: C/BOND 'SURFMIST'
ALUMINIUM FRAMED SHOP FRONT WINDOWS
WITH MIN. 6.38mm LAMINATED GLASS. ENERGY
RATING AS PER 'THE STUDY' REPORT
LASER CUT STEEL SIGNAGE (EACH LETTER SEPARATE PIECE)
ON STAND-OFF BRACKETS TO SIT FORWARD OF CLADDING
LINE. CLIENT TO PROVIDE ARTOWRK DESIGN & COLOURS
CL
900 7221 14466
1566
900
EXIST. KNEE HEIGHT
FFL 00
SHOWROOM CL
MEZZANINE FFL
MEZZ. OFFICE CL
1111
2180
2270
2700
1300
3600
LYSAGHT LONGLINE 305 STEEL CLADDING
INSTALLED AS MANUFACTURERS SPECIFICATIONS
C/BOND FINISH: C/BOND 'SURFMIST'
LASER CUT STEEL SIGNAGE (EACH LETTER SEPARATE PIECE)
ON STAND-OFF BRACKETS TO SIT FORWARD OF CLADDING
LINE. CLIENT TO PROVIDE ARTOWRK DESIGN & COLOURS
CONCRETE PANEL BEYOND
ALUMINIUM FRAMED SHOP FRONT WINDOWS
WITH MIN. 6.38mm LAMINATED GLASS. ENERGY
RATING AS PER 'THE STUDY' REPORT
EXIST. RIDGE
100
1200
102400
102470
102700
EQ.10
EQ.10
EQ.10
EQ.10
1200 CFC PANEL
SPACINGS
CFC P
ANEL
SPACINGS
FASCIA CAPPING
JAMES HARDIE 1200 x (VARYING
LENGTH) 9mm EXOTEC PANELS (ON JH
35mm BATTEN) WITH 10mm EXPRESSED
JOINTS INSTALLED AS PER
MANUFACTURERS SPECIFICATIONS
PAINT FINISH. COLOUR: PAINT A
3150
1300
7600
1300
2553
2347
2700
CONCRETE TILT PANEL BEYOND WITH
PAINT FINISH. COLOUR: PAINT B
STEEL COLUMN & STEEL LOUVRE BLADE
SCREEN STRUCTURE WITH POWDER COAT
FINISH. COLOUR: C/BOND 'SURFMIST'
PRESSED STEEL FASCIA CAPPING
PAINT FINISH. COLOUR: PAINT A
JAMES HARDIE 1200 x (VARYING
LENGTH) 9mm EXOTEC PANELS (ON JH
35mm BATTEN) WITH FLUSH FINISHED
JOINTS INSTALLED AS PER
MANUFACTURERS SPECIFICATIONS
PAINT FINISH. COLOUR: PAINT B
FFFFFF
F
F
F
F
F
F F F F F F F
LL
FFFFFFFFFF
F
STEEL FRAMED AWNING STRUCTURE AS
DETAILS. C/BOND FINISH: C/BOND 'SURFMIST'
FALL HIDDEN GUTTER EAST AND POP
DOWNPIPE INTO DUCT
CONCRETE TILT PANEL BELOW
SHOPFRONT GLAZING WITH PAINT
FINISH. COLOUR: PAINT B
CONCRETE TILT PANEL BEYOND WITH
PAINT FINISH. COLOUR: PAINT B
FIN
900
SIGN
1566
170
CL
900
SIGN
7221
LL
L
50
(BUILDER TO CONFIRM ON SITE
PRIOR TO POURING TILT PANELS)
1300
1400
200
DATEPROJECT NO.
DRAWING NUMBER. Rev.
DRAWING
ADDRESS
CLIENT
PROJECT
©
DRAWN BYDESIGNED BY
A11. THIS DRAWING IS COPYRIGHT PROTECTED AND REMAINS THE PROPERTY OF MERGE BUILDING
DESIGN (ABN 25 048 357 461) AND SHALL NOT BE USED FOR ANY OTHER PURPOSE THAN
ORIGINALLY INTENDED
2. READ FIGURED DIMENSIONS IN PREFERENCE TO SCALE. ALL DIMENSIONS IN mm U.O.N.
3. BUILDER TO CHECK AND CONFIRM ALL MEASUREMENTS, LEVELS & DETAILS PRIOR TO THE
COMMENCEMENT OF ANY WORK OR FINANCIAL COMMITMENT. BUILDER TO CHECK AND CONFIRM
MEASUREMENTS OF EXISTING BUILDING
4. THIS DRAWING TO BE READ IN CONJUNCTION WITH ALL BUILDING DESIGN DRAWINGS,
ARCHITECTURAL NATSPEC SPECIFICATION, ALL CONSULTANTS DRAWINGS AND SPECIFICATIONS &
MANUFACTURERS SPECIFICATIONS
5. ALL WORKSMANSHIP AND MATERIALS TO BE IN ACCORDANCE WITH THE MOST CURRENT
BUILDING REGULATIONS, S.A.A. CODES AND AUST. STANDARDS
PHONE: (08) 97 215 300 FAX: (08) 97 215 800
EMAIL: [email protected]
MAIL: PO BOX 406, Bunbury, WA, 6231
WEB: www.mergedesign.com.au
10/01/2017 3:12:09 PM
AALOT 101 (#69) CRAIGIE ST, BUNBURY
1525
C03
ADDITIONS AND RENOVATIONS TO EXISTING
INDUSTRIAL BUILDING
PRIME INDUSTRIAL
EXTERIOR LED SIGNAGE
AGMASTERSL SL
REVISION SCHEDULE
REV. DATE DESCRIPTION
AA 10-1-2017 RE-ISSUED FOR SIGNAGE
1 : 100SK06
PROPOSED WEST ELEVATION1
1 : 100SK06
EXISTING EAST ELEVATION2
3D PERSEPECTIVE (TAKEN FROM CENTRE OF TRAFFIC LIGHTS)3
EXTERIOR 'LED' SIGNAGE 1 : 100SK06
PROPOSED SOUTH ELEVATION4
7.00°7.00°
CRAIGIE STREET
PARAPET WALL (CONCRETE)PARAPET WALL (CONCRETE)PARAPET WALL (CONCRETE)PARAPET WALL (CONCRETE)
EXISTING TRIMDECK ROOF SHEETING
EXISTING T
RIMDECK R
OOF
SHEETING (@ L
OWER L
EVEL)
EXISTING TRIMDECK ROOF
SHEETING (@ LOWER LEVEL)
EXISTING TRIMDECK ROOF SHEETING
7.00°
7.00°
7.00°
7.00°
7.00°
5.0
0°
5.0
0° 4.50° 4.50°
C/BOND (SURFMIST) TRIMDECK ROOF SHEETING
C/BOND (SURFMIST) TRIMDECK
ROOF SHEETING
287
22000
500
PROPOSED W
ESTERN 'LED' SIGN
DATEPROJECT NO.
DRAWING NUMBER. Rev.
DRAWING
ADDRESS
CLIENT
PROJECT
©
DRAWN BYDESIGNED BY
A11. THIS DRAWING IS COPYRIGHT PROTECTED AND REMAINS THE PROPERTY OF MERGE BUILDING
DESIGN (ABN 25 048 357 461) AND SHALL NOT BE USED FOR ANY OTHER PURPOSE THAN
ORIGINALLY INTENDED
2. READ FIGURED DIMENSIONS IN PREFERENCE TO SCALE. ALL DIMENSIONS IN mm U.O.N.
3. BUILDER TO CHECK AND CONFIRM ALL MEASUREMENTS, LEVELS & DETAILS PRIOR TO THE
COMMENCEMENT OF ANY WORK OR FINANCIAL COMMITMENT. BUILDER TO CHECK AND CONFIRM
MEASUREMENTS OF EXISTING BUILDING
4. THIS DRAWING TO BE READ IN CONJUNCTION WITH ALL BUILDING DESIGN DRAWINGS,
ARCHITECTURAL NATSPEC SPECIFICATION, ALL CONSULTANTS DRAWINGS AND SPECIFICATIONS &
MANUFACTURERS SPECIFICATIONS
5. ALL WORKSMANSHIP AND MATERIALS TO BE IN ACCORDANCE WITH THE MOST CURRENT
BUILDING REGULATIONS, S.A.A. CODES AND AUST. STANDARDS
PHONE: (08) 97 215 300 FAX: (08) 97 215 800
EMAIL: [email protected]
MAIL: PO BOX 406, Bunbury, WA, 6231
WEB: www.mergedesign.com.au
17/11/2016 7:49:21 AM
XLOT 101 (#69) CRAIGIE ST, BUNBURY
1525
C02
ADDITIONS AND RENOVATIONS TO EXISTING
INDUSTRIAL BUILDING
PRIME INDUSTRIAL
EXTERIOR LED SIGNAGE
SIGNAGESL SL
REVISION SCHEDULE
REV. DATE DESCRIPTION
W 4-10-2016 ISSUED FOR SIGNAGE APPROVAL
X 17-11-2016 RE-ISSUED FOR SIGNAGE APPROVAL
1 : 200SK08
ROOF PLAN - LED SIGNAGE1
EXTERIOR 'LED' SIGNAGE
2700
3600
2700
3600
24002400
900
2100
3600
2700
3600
2700
3600
2700
3600
2000
2700
1000
2700
2700
1300
2000
25002600
EXIST. KNEE HEIGHT
FFL 00
SHOWROOM CL
MEZZANINE FFL
FHRFHR
7150
1300
3600
EXIST. RIDGE
260
8450
260
NEW SHOWROOM/OFFICE
8970
1111
8450
3600
8850
F
LLLL
SFSF
WALL MOUNTED 'LED' ADVERTISING
SCREEN. SUPPORTING STRUCTURE
AND SCREEN BY OTHERS
2750
450
LED S
IGN
LED SIGN
JAMES HARDIE 1200 x 3000 9mm EXOTEC PANELS (ON JH 35mm
BATTEN) WITH 10mm EXPRESSED JOINTS TO FORM FEATURE FIN
PROTRUSIONS INSTALLED AS PER MANUFACTURERS SPECIFICATIONS
PAINT FINISH. COLOUR: PAINT A
CONCRETE TILT PANEL
BEYOND WITH PAINT
FINISH. COLOUR: PAINT B
3200
5650
STEEL LOUVRE BLADE SCREEN STRUCTURE
WITH POWDER COAT FINISH. COLOUR:
C/BOND 'SURFMIST'
CONCRETE TILT PANEL BEYOND WITH
PAINT FINISH. COLOUR: PAINT B
PRECAST CONCRETE AWNING PANEL
WITH PAINT FINISH. COLOUR: PAINT A
ALUMINIUM FRAMED SHOP FRONT WINDOWS
WITH MIN. 6.38mm LAMINATED GLASS. ENERGY
RATING AS PER 'THE STUDY' REPORT
28722000 500
9300
2750
LOUVRE WINDOWS BEHIND
FIRE ESCAPE DOOR CUT IN TO
EXISTING PURLINS/CLADDING
EXISTING ROOF
SHEETING
NEW SHOWROOM/OFFICE
EXISTING EXISTING
3200
EXIST. KNEE HEIGHT
FFL 00
SHOWROOM CL
MEZZANINE FFL
MEZZ. OFFICE CL
EXIST. RIDGE
1200 10 1200 10 120010
1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 402
NEW SHOWROOM/OFFICE
100
1200
102400
102470
102700
CFC P
ANEL
SPACINGS
CFC PANEL
SPACINGS
300 FIN
3150
1300
2700
1300
3600
1111
8450
3600
L F F L F F L F FLLL
L F FL
FFF
WINDOWS BEHIND
LYSAGHT LONGLINE 305 STEEL CLADDING INSTALLED AS
MANUFACTURERS SPECIFICATIONS OVER CONCRETE TILT
PANELS. C/BOND FINISH: C/BOND 'SURFMIST'
JAMES HARDIE 1200 x (VARYING LENGTH) 9mm EXOTEC PANELS (ON JH
35mm BATTEN) WITH 10mm EXPRESSED JOINTS INSTALLED AS PER
MANUFACTURERS SPECIFICATIONS PAINT FINISH. COLOUR: PAINT A
STEEL COLUMN & STEEL LOUVRE BLADE
SCREEN STRUCTURE WITH POWDER COAT
FINISH. COLOUR: C/BOND 'SURFMIST'
ALUMINIUM FRAMED SHOP FRONT WINDOWS
WITH MIN. 6.38mm LAMINATED GLASS. ENERGY
RATING AS PER 'THE STUDY' REPORT
LASER CUT STEEL SIGNAGE (EACH LETTER SEPARATE PIECE)
ON STAND-OFF BRACKETS TO SIT FORWARD OF CLADDING
LINE. CLIENT TO PROVIDE ARTOWRK DESIGN & COLOURS
CL
900 7221 14466
1566
900
EXIST. KNEE HEIGHT
FFL 00
SHOWROOM CL
MEZZANINE FFL
MEZZ. OFFICE CL
1111
2180
2270
2700
1300
3600
LYSAGHT LONGLINE 305 STEEL CLADDING
INSTALLED AS MANUFACTURERS SPECIFICATIONS
C/BOND FINISH: C/BOND 'SURFMIST'
LASER CUT STEEL SIGNAGE (EACH LETTER SEPARATE PIECE)
ON STAND-OFF BRACKETS TO SIT FORWARD OF CLADDING
LINE. CLIENT TO PROVIDE ARTOWRK DESIGN & COLOURS
CONCRETE PANEL BEYOND
ALUMINIUM FRAMED SHOP FRONT WINDOWS
WITH MIN. 6.38mm LAMINATED GLASS. ENERGY
RATING AS PER 'THE STUDY' REPORT
EXIST. RIDGE
100
1200
102400
102470
102700
EQ.10
EQ.10
EQ.10
EQ.10
1200 CFC PANEL
SPACINGS
CFC P
ANEL
SPACINGS
FASCIA CAPPING
JAMES HARDIE 1200 x (VARYING
LENGTH) 9mm EXOTEC PANELS (ON JH
35mm BATTEN) WITH 10mm EXPRESSED
JOINTS INSTALLED AS PER
MANUFACTURERS SPECIFICATIONS
PAINT FINISH. COLOUR: PAINT A
3150
1300
7600
1300
2553
2347
2700
CONCRETE TILT PANEL BEYOND WITH
PAINT FINISH. COLOUR: PAINT B
STEEL COLUMN & STEEL LOUVRE BLADE
SCREEN STRUCTURE WITH POWDER COAT
FINISH. COLOUR: C/BOND 'SURFMIST'
PRESSED STEEL FASCIA CAPPING
PAINT FINISH. COLOUR: PAINT A
JAMES HARDIE 1200 x (VARYING
LENGTH) 9mm EXOTEC PANELS (ON JH
35mm BATTEN) WITH FLUSH FINISHED
JOINTS INSTALLED AS PER
MANUFACTURERS SPECIFICATIONS
PAINT FINISH. COLOUR: PAINT B
FFFFFF
F
F
F
F
F
F F F F F F F
LL
FFFFFFFFFF
F
STEEL FRAMED AWNING STRUCTURE AS
DETAILS. C/BOND FINISH: C/BOND 'SURFMIST'
FALL HIDDEN GUTTER EAST AND POP
DOWNPIPE INTO DUCT
CONCRETE TILT PANEL BELOW
SHOPFRONT GLAZING WITH PAINT
FINISH. COLOUR: PAINT B
CONCRETE TILT PANEL BEYOND WITH
PAINT FINISH. COLOUR: PAINT B
FIN
900
SIGN
1566
170
CL
900
SIGN
7221
LL
L
50
(BUILDER TO CONFIRM ON SITE
PRIOR TO POURING TILT PANELS)
1300
1400
200
DATEPROJECT NO.
DRAWING NUMBER. Rev.
DRAWING
ADDRESS
CLIENT
PROJECT
©
DRAWN BYDESIGNED BY
A11. THIS DRAWING IS COPYRIGHT PROTECTED AND REMAINS THE PROPERTY OF MERGE BUILDING
DESIGN (ABN 25 048 357 461) AND SHALL NOT BE USED FOR ANY OTHER PURPOSE THAN
ORIGINALLY INTENDED
2. READ FIGURED DIMENSIONS IN PREFERENCE TO SCALE. ALL DIMENSIONS IN mm U.O.N.
3. BUILDER TO CHECK AND CONFIRM ALL MEASUREMENTS, LEVELS & DETAILS PRIOR TO THE
COMMENCEMENT OF ANY WORK OR FINANCIAL COMMITMENT. BUILDER TO CHECK AND CONFIRM
MEASUREMENTS OF EXISTING BUILDING
4. THIS DRAWING TO BE READ IN CONJUNCTION WITH ALL BUILDING DESIGN DRAWINGS,
ARCHITECTURAL NATSPEC SPECIFICATION, ALL CONSULTANTS DRAWINGS AND SPECIFICATIONS &
MANUFACTURERS SPECIFICATIONS
5. ALL WORKSMANSHIP AND MATERIALS TO BE IN ACCORDANCE WITH THE MOST CURRENT
BUILDING REGULATIONS, S.A.A. CODES AND AUST. STANDARDS
PHONE: (08) 97 215 300 FAX: (08) 97 215 800
EMAIL: [email protected]
MAIL: PO BOX 406, Bunbury, WA, 6231
WEB: www.mergedesign.com.au
17/11/2016 7:49:23 AM
XLOT 101 (#69) CRAIGIE ST, BUNBURY
1525
C03
ADDITIONS AND RENOVATIONS TO EXISTING
INDUSTRIAL BUILDING
PRIME INDUSTRIAL
EXTERIOR LED SIGNAGE
SIGNAGESL SL
REVISION SCHEDULE
REV. DATE DESCRIPTION
W 4-10-2016 ISSUED FOR SIGNAGE APPROVAL
X 17-11-2016 RE-ISSUED FOR SIGNAGE APPROVAL
1 : 100SK06
PROPOSED WEST ELEVATION1
1 : 100SK06
EXISTING EAST ELEVATION2
3D PERSEPECTIVE (TAKEN FROM CENTRE OF TRAFFIC LIGHTS)3
EXTERIOR 'LED' SIGNAGE 1 : 100SK06
PROPOSED SOUTH ELEVATION4
2700
3600
2700
3600
24002400
900
2100
3600
2700
3600
2700
3600
2700
3600
2000
2700
1000
2700
2700
1300
2000
25002600
EXIST. KNEE HEIGHT
FFL 00
SHOWROOM CL
MEZZANINE FFL
FHRFHR
7150
1300
3600
EXIST. RIDGE
260
8450
260
NEW SHOWROOM/OFFICE
8970
1111
8450
3600
8850
F
LLLL
SFSF
WALL MOUNTED 'LED' ADVERTISING
SCREEN. SUPPORTING STRUCTURE
AND SCREEN BY OTHERS
2750
450
LED S
IGN
LED SIGN
JAMES HARDIE 1200 x 3000 9mm EXOTEC PANELS (ON JH 35mm
BATTEN) WITH 10mm EXPRESSED JOINTS TO FORM FEATURE FIN
PROTRUSIONS INSTALLED AS PER MANUFACTURERS SPECIFICATIONS
PAINT FINISH. COLOUR: PAINT A
CONCRETE TILT PANEL
BEYOND WITH PAINT
FINISH. COLOUR: PAINT B
3200
5650
STEEL LOUVRE BLADE SCREEN STRUCTURE
WITH POWDER COAT FINISH. COLOUR:
C/BOND 'SURFMIST'
CONCRETE TILT PANEL BEYOND WITH
PAINT FINISH. COLOUR: PAINT B
PRECAST CONCRETE AWNING PANEL
WITH PAINT FINISH. COLOUR: PAINT A
ALUMINIUM FRAMED SHOP FRONT WINDOWS
WITH MIN. 6.38mm LAMINATED GLASS. ENERGY
RATING AS PER 'THE STUDY' REPORT
28722000 500
9300
2750
LOUVRE WINDOWS BEHIND
FIRE ESCAPE DOOR CUT IN TO
EXISTING PURLINS/CLADDING
EXISTING ROOF
SHEETING
NEW SHOWROOM/OFFICE
EXISTING EXISTING
3200
WEST ELEVATION TOTAL AREA: 1021m²
PROPOSED LED SIGNAGE AREA: 60.50m²
% OF ELEVATION WITH SIGN: 6%
EXIST. KNEE HEIGHT
FFL 00
SHOWROOM CL
MEZZANINE FFL
MEZZ. OFFICE CL
EXIST. RIDGE
1200 10 1200 10 120010
1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 1200 10 402
NEW SHOWROOM/OFFICE
100
1200
102400
102470
102700
CFC P
ANEL
SPACINGS
CFC PANEL
SPACINGS
300 FIN
3150
1300
2700
1300
3600
1111
8450
3600
L F F L F F L F FLLL
L F FL
FFF
WINDOWS BEHIND
LYSAGHT LONGLINE 305 STEEL CLADDING INSTALLED AS
MANUFACTURERS SPECIFICATIONS OVER CONCRETE TILT
PANELS. C/BOND FINISH: C/BOND 'SURFMIST'
JAMES HARDIE 1200 x (VARYING LENGTH) 9mm EXOTEC PANELS (ON JH
35mm BATTEN) WITH 10mm EXPRESSED JOINTS INSTALLED AS PER
MANUFACTURERS SPECIFICATIONS PAINT FINISH. COLOUR: PAINT A
STEEL COLUMN & STEEL LOUVRE BLADE
SCREEN STRUCTURE WITH POWDER COAT
FINISH. COLOUR: C/BOND 'SURFMIST'
ALUMINIUM FRAMED SHOP FRONT WINDOWS
WITH MIN. 6.38mm LAMINATED GLASS. ENERGY
RATING AS PER 'THE STUDY' REPORT
LASER CUT STEEL SIGNAGE (EACH LETTER SEPARATE PIECE)
ON STAND-OFF BRACKETS TO SIT FORWARD OF CLADDING
LINE. CLIENT TO PROVIDE ARTOWRK DESIGN & COLOURS
CL
7700 7221 7666
1566
900
EXIST. KNEE HEIGHT
FFL 00
SHOWROOM CL
MEZZANINE FFL
MEZZ. OFFICE CL
1111
2180
2270
2700
1300
3600
LYSAGHT LONGLINE 305 STEEL CLADDING
INSTALLED AS MANUFACTURERS SPECIFICATIONS
C/BOND FINISH: C/BOND 'SURFMIST'
LASER CUT STEEL SIGNAGE (EACH LETTER SEPARATE PIECE)
ON STAND-OFF BRACKETS TO SIT FORWARD OF CLADDING
LINE. CLIENT TO PROVIDE ARTOWRK DESIGN & COLOURS
CONCRETE PANEL BEYOND
ALUMINIUM FRAMED SHOP FRONT WINDOWS
WITH MIN. 6.38mm LAMINATED GLASS. ENERGY
RATING AS PER 'THE STUDY' REPORT
EXIST. RIDGE
100
1200
102400
102470
102700
EQ.10
EQ.10
EQ.10
EQ.10
1200 CFC PANEL
SPACINGS
CFC P
ANEL
SPACINGS
FASCIA CAPPING
JAMES HARDIE 1200 x (VARYING
LENGTH) 9mm EXOTEC PANELS (ON JH
35mm BATTEN) WITH 10mm EXPRESSED
JOINTS INSTALLED AS PER
MANUFACTURERS SPECIFICATIONS
PAINT FINISH. COLOUR: PAINT A
3150
1300
7600
1300
2553
2347
2700
CONCRETE TILT PANEL BEYOND WITH
PAINT FINISH. COLOUR: PAINT B
STEEL COLUMN & STEEL LOUVRE BLADE
SCREEN STRUCTURE WITH POWDER COAT
FINISH. COLOUR: C/BOND 'SURFMIST'
PRESSED STEEL FASCIA CAPPING
PAINT FINISH. COLOUR: PAINT A
JAMES HARDIE 1200 x (VARYING
LENGTH) 9mm EXOTEC PANELS (ON JH
35mm BATTEN) WITH FLUSH FINISHED
JOINTS INSTALLED AS PER
MANUFACTURERS SPECIFICATIONS
PAINT FINISH. COLOUR: PAINT B
FFFFFF
F
F
F
F
F
F F F F F F F
LL
FFFFFFFFFF
F
STEEL FRAMED AWNING STRUCTURE AS
DETAILS. C/BOND FINISH: C/BOND 'SURFMIST'
FALL HIDDEN GUTTER EAST AND POP
DOWNPIPE INTO DUCT
CONCRETE TILT PANEL BELOW
SHOPFRONT GLAZING WITH PAINT
FINISH. COLOUR: PAINT B
CONCRETE TILT PANEL BEYOND WITH
PAINT FINISH. COLOUR: PAINT B
FIN
900
SIGN
1566
170
CL
900
SIGN
7221
LL
L
50
(BUILDER TO CONFIRM ON SITE
PRIOR TO POURING TILT PANELS)
1300
1400
200
DATEPROJECT NO.
DRAWING NUMBER. Rev.
DRAWING
ADDRESS
CLIENT
PROJECT
©
DRAWN BYDESIGNED BY
A11. THIS DRAWING IS COPYRIGHT PROTECTED AND REMAINS THE PROPERTY OF MERGE BUILDING
DESIGN (ABN 25 048 357 461) AND SHALL NOT BE USED FOR ANY OTHER PURPOSE THAN
ORIGINALLY INTENDED
2. READ FIGURED DIMENSIONS IN PREFERENCE TO SCALE. ALL DIMENSIONS IN mm U.O.N.
3. BUILDER TO CHECK AND CONFIRM ALL MEASUREMENTS, LEVELS & DETAILS PRIOR TO THE
COMMENCEMENT OF ANY WORK OR FINANCIAL COMMITMENT. BUILDER TO CHECK AND CONFIRM
MEASUREMENTS OF EXISTING BUILDING
4. THIS DRAWING TO BE READ IN CONJUNCTION WITH ALL BUILDING DESIGN DRAWINGS,
ARCHITECTURAL NATSPEC SPECIFICATION, ALL CONSULTANTS DRAWINGS AND SPECIFICATIONS &
MANUFACTURERS SPECIFICATIONS
5. ALL WORKSMANSHIP AND MATERIALS TO BE IN ACCORDANCE WITH THE MOST CURRENT
BUILDING REGULATIONS, S.A.A. CODES AND AUST. STANDARDS
PHONE: (08) 97 215 300 FAX: (08) 97 215 800
EMAIL: [email protected]
MAIL: PO BOX 406, Bunbury, WA, 6231
WEB: www.mergedesign.com.au
29/11/2016 2:16:50 PM
XLOT 101 (#69) CRAIGIE ST, BUNBURY
1525
C03
ADDITIONS AND RENOVATIONS TO EXISTING
INDUSTRIAL BUILDING
PRIME INDUSTRIAL
EXTERIOR LED SIGNAGE
SIGNAGESL SL
REVISION SCHEDULE
REV. DATE DESCRIPTION
W 4-10-2016 ISSUED FOR SIGNAGE APPROVAL
X 17-11-2016 RE-ISSUED FOR SIGNAGE APPROVAL
1 : 100SK06
PROPOSED WEST ELEVATION1
1 : 100SK06
EXISTING EAST ELEVATION2
3D PERSEPECTIVE (TAKEN FROM CENTRE OF TRAFFIC LIGHTS)3
EXTERIOR 'LED' SIGNAGE 1 : 100SK06
PROPOSED SOUTH ELEVATION4
7
West View Point ( Intersection Halifax / South West Highway)
Southern Viewpoint (South West Highway)
8
Northern View Point ( Intersection Roberts / SouthWest Highway)