Upload
stephanie-page
View
218
Download
2
Tags:
Embed Size (px)
Citation preview
Impact of LSS5 dump on other SPS systems
BG 24/2/15
Present LSS5
Tentative new HW for extraction to internal dump in LSS5
Or this (FV checking whether advantageous)?
Downstream QD.517
Element Function Used by? Equipment owner
Action Impact
BBLRM.51774 Beam-beam wire prototype HL-LHC BE-BI Displace Medium ?
BBLRM.51772 Beam-beam wire prototype HL-LHC BE-BI Displace Medium ?
BBLR.51771 Beam-beam wire prototype HL-LHC BE-BI Displace / decommission ? Medium ?
BBLR.51760 Beam-beam wire prototype HL-LHC BE-BI Displace / decommission ? Medium ?
MDPH.51754 H corrector, ecloud LIU TE-MSC Move to new location ? Medium ?
MDPH.51753 H corrector, ecloud LIU TE-MSC Move to new location ? Medium ?
VVSB.51752 Sector valve ? TE-VSC ? ?
BWSRE.51740 New wirescanner prototype LIU / OP BE-BI Move to new location Medium
MDVW.51736 V dipole for BGI LIU TE-MSC Move to new location ? High ?
MDVW.51734 V dipole for BGI LIU TE-MSC Move to new location ? High ?
BIPMV.51734 BGI detector LIU BE-BI Move to new location ? Medium ?
MDVW.51732 V dipole for BGI LIU TE-MSC Move to new location ? High ?
BWSD.51731 Linear wirescanner OP BE-BI Move to new location Medium
Upstream QF(A).518
Element Function Used by? Equipment owner
Action Impact
BPH.51808 Regular MOPOS pickup OP BE-BI Replace with BPCE Low ?
MDH.51807 Regular H orbit corrector OP TE-MSC Replace with Low ?
BL.51808 (?) BLM, SPS ring OP BE-BI Displace slightly upstream Low
BL.51800 (?) BLM, UA9 ? UA9 ? BE-BI ? ?
TECS.51797 Goniometer, UA9 UA9 EN-STI Move to new location ? High ?
TECS.51797 Goniometer, UA9 UA9 EN-STI Move to new location ? High ?
BSHV.51792/3/4/5 Goniometer/detector, UA9 UA9 EN-STI Move to new location ? High ?
MDVB.51777 V orbit corrector ? TE-MSC ? ?
Downstream QF(A).518
In addition, need to replace all vacuum chambers QFA.518-QD519 by large aperture (Ø250 mm tbc)
Element Function Used by? Equipment owner
Action Impact
MDHW.51853 H corrector, ecloud LIU TE-MSC Move to new location ? Medium
MDHW.51838 H corrector, ecloud LIU TE-MSC Move to new location ? Medium
MDHW.51836 H corrector, ecloud LIU TE-MSC Move to new location ? Medium
MDHW.51832 H corrector, ecloud LIU TE-MSC Move to new location ? Medium
VVSB.51820 Sector valve OP/LIU? TE-VAC Displace slightly/move to new location ? Low/medium
QF.51810 Main quadrupole OP TE-MSC Replace with enlarged QFA Medium
Upstream QD.519
Element Function Used by? Equipment owner
Action Impact
BPV.51908 Regular MOPOS pickup OP BE-BI Move to downstream QD.51910 Low
MDV.51907 Regular V orbit corrector OP TE-MSC Move to downstream QD.51910 Low
BL.51904 (?) BLM, UA9 (?) UA9 (?) BE-BI ? ?
BL.51908 (?) BLM, SPS ring OP BE-BI Move to downstream QD.51910 Low
BPMBV.51905 LHC-type BPM OP, MD BE-BI Move to downstream QD.51910 (?) Low
BRCV.51899 LEP-type V collimator, UA9 UA9 EN-STI ? ?
BRCH.51902 LEP-type H collimator, UA9 UA9 EN-STI ? ?
BCTDC.51895 Interlock BCT primary ions OP BE-BI Move to new location (tbd) Medium
BCTDC.51897 Interlock BCT primary ions OP BE-BI Move to new location (tbd) Medium
BCTFS.51894 FBCT for synchronisation ? BE-BI ? ?
Downstream QD.519
Element Function Used by? Equipment owner
Action Impact
BL.51938 BLM, UA9/Coll (?) UA9/Coll (?) BE-BI Move to new location (?) Low
XRPH.51937 Roman pot, UA9 UA9 EN-STI Move to new location (?) ?
BL.51936 (?) BLM, UA9/Coll (?) UA9/Coll (?) BE-BI Move to new location (?) Low
TCSM.51934 Test LHC collimator, UA9 (?) Coll/UA9 (?) EN-STI Move to new location (?) Medium ?
VVSB.51933 Sector valve, Coll OP/Coll (?) TE-MSC Move to new location with TCS (?) Low ?
Upstream QF.520
Element Function Used by? Equipment owner
Action Impact
BPH.52008 Regular MOPOS pickup OP BE-BI Keep None
MDH.52007 Regular H orbit corrector OP TE-MSC Keep None
LSFA.52005 Chromaticity sextupole OP TE-MSC Keep None
LOEN.52002 Extraction octupole OP (?) TE-MSC Keep (decommission?) None
BPMBH.51999 Large LHC-type BPM OP, MD BE-BI Keep None
TACW.51998 Cherenkov detector, UA9 UA9 EN-STI? Displace with other UA9 elements ? Medium ?
BMO.51997 Injection matching OTR LIU BE-BI Move to new location (decommission?) Medium ?
BWSA.51995 Rotational wirescanner OP BE-BI Keep / move to new location ? Medium ?
XRP.51991 Roman pot, UA9 UA9 EN-STI Move to new location (?) ?
UA9 in LSS5….
Main questions• One MKDV tank upstream of QF518 or not?
– 2 or 3 MKDV– Dynamic range of main switches– (re)location of SSS equipment – COD, BPM.
• New functional locations needed for several items– Interlock BCTs– Instruments– Test collimators– BBLR prototypes– eCloud test systems
• Identify remaining “?” equipment• UA9
– Will it be needed after LS2?– If so, what is a possible configuration in LSS5?