Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-1
Impervia® Installation Details
IntroductionTypical Sealant Placement Details ...................................................................................................................................F-ID-2
Fin Installation DetailsGeneral Notes ...................................................................................................................................................................F-ID-3
Integral Nailing Fin with Siding .......................................................................................................................................F-ID-4
Integral Nailing Fin with Brick Veneer ............................................................................................................................F-ID-6
Integral Nailing Fin with Southwest-Style Hardcoat on Insulation Board ..................................................................F-ID-7
Integral Nailing Fin with Vinyl Siding ..............................................................................................................................F-ID-8
Block Frame Sliding Door with Siding ............................................................................................................................F-ID-9
Block Frame Sliding Door with Brick Veneer ...............................................................................................................F-ID-10
Block Frame Sliding Door with Southwest-Style Hardcoat Stucco on Insulation Board ........................................F-ID-11
Block Frame Sliding Door with Vinyl Siding ................................................................................................................F-ID-12
Subsill and Receptor Installation DetailsGeneral Notes .................................................................................................................................................................F-ID-13
L-Receptor Installation ....................................................................................................................................................F-ID-14
Clip Installation DetailsGeneral Notes .................................................................................................................................................................F-ID-15
Block Frame Sliding Window with Concrete Block and Brick Veneer ......................................................................F-ID-16
Block Frame Sliding Door with Concrete Block and Brick Veneer ...........................................................................F-ID-17
Pocket ReplacementGeneral Notes .................................................................................................................................................................F-ID-19
Block Frame Double-Hung Pocket Replacement ........................................................................................................F-ID-20
Installation AccessoriesReinforcing Mullion Accessories ...................................................................................................................................F-ID-22
Tube Mullion ....................................................................................................................................................................F-ID-24
Interior Trim ......................................................................................................................................................................F-ID-27
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-2
Impervia® Installation Details
This section presents typical construction details and available accessories for single units in new construction.
The objectives of installation systems are to:
• Secure the attachment of the window to the wall
• Limit air and water infiltration
• Allow for expansion and contraction
ImportantDetermining and meeting the structural load requirements and design of the rough opening is the responsibility of the architect or engineer. Window frame systems are not designed to support additional elements or components of the building wall system.
Fins and clips are the two basic methods of the Pella® Impervia® window attachments.
• Fin Installation—applicable when window units can be installed from the exterior prior to applying lap siding or other cladding material.
• Block Frame with Jamb Screws or Masonry Clips—applicable when the construction materials or sequence dictates that window units be installed from the interior or after the wall system is completely constructed. This method of attachment is typical in projects with masonry veneer, such as brick or precast concrete.
Aside from fins and clips for single punch openings, this section reviews other available Impervia accessories.
Typical Sealant Placement DetailsProper application of perimeter sealant to prevent leakage around windows is the responsibility of the installer.
Use Pella Window and Door Installation Sealant or equivalent high quality, multi-purpose sealant. Typical sealant placement details are shown below. Apply sealants according to their label directions and ASTM C1193. Refer to the Installation Accessories on the following pages and the Composite and Combination section for additional information.
Special Note: Some manufacturers of sealants recommend or require the use of primers to ensure adequate adhesion to painted porous surfaces.
[6]
1/4" [6]
1/4"
use high pressure or latex foam.)create full interior seal. (Do NOTwindow and door foam sealant topressure polyurethane insulating1" bead of Low expansion, lowapplications; apply continuousFor use in most residential
or
use high pressure or latex foam.)
foam backer rod.
®
ASTM C1193.
Pella Window and Door Installation
Water resistant closed cell
according to label instuctions andSealant. Apply continuous sealant
interior for commercial installations.sealant is recommended onWater resistant backer rod and
PERIMETER SEALANT DETAILTYPICAL INTERIOR
PERIMETER SEALANT DETAILTYPICAL EXTERIOR
CONSTRUCTIONWALL
CONSTRUCTIONWALL
Introduction, Typical Sealant Placement Details
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-3
Impervia® Installation Details
When to Use this Installation Method
This installation is best for construction methods that will permit the unit to be installed from the exterior prior to the lap siding or other similar material.
There are different fin installations to consider:
Integral Nailing Fin Design—features a continuous fin allowing the window frame to be integrated into the building’s weather resistive wrap using the Pella SmartFlash® Tape installation method.
The addition of the standard fin allows the window to be installed in the same manner as the Integral Nailing Fin design. The fins allow the window frame to be integrated into the building’s weather resistive wrap using the Pella SmartFlash® Tape installation method.
Block Frame units can be field-joined together (see Composites and Combinations section for joining limitations); and may easily be used in a replacement window without removing the existing frame or damaging the exterior.
Products Available for this Installation
All Pella® Impervia® windows and doors.
Important Installation Procedures
• When rigid insulation or other compressible sheathing is used, provide solid blocking for fin attachment.• Shim unit in the opening plumb level and square. • Provide a primary and secondary air and water seal around the perimeter of the unit.• Primary Seal—Seal the unit to the exterior finish
material.• Secondary Seal—Apply Pella SmartFlash® foil backed butyl window and door flashing tape (or equivalent) at rough opening sill and over
installation fins at head and jambs in watershed order. See product installation instructions for detailed directions.• Interior Air Seal—Apply around the perimeter of the unit by applying a one inch deep bead of low expansion, low pressure polyurethane
insulating window and door foam sealant - (DO NOT use high pressure or latex foams)• Commercial and/or large complex composites may require additional installation design considerations and attachments. See the Composites
and Combinations section of this manual.• See page 2 in this section for typical sealant placement details.
Notes
• Details shown are not intended to reflect complete installation procedures, however they do reflect basic installation concepts. Refer to window and door installation instructions provided with the product for detailed directions.
• Details show various wall systems with different types of Impervia products. Details with other Pella products in the same wall construction should be similar.
• Figures in parentheses following or adjacent to dimensions are International (metric) equivalents in millimeters. For metric equivalents other than those shown, multiply dimensions in inches by 25.4.
• Your local Pella sales representative can assist with other more complex and unique applications.
General Notes on Fin Installation
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-4
Impervia® Installation Details
WATER RESISTANT BARRIER BY OTHERSContinuous water-resistive barrier attached to the wall sheathing.
FLASHING BY OTHERSMetal head flashing.
SMARTFLASH® INSTALLATION TAPEIntegrate the window and door flashing tape into the wall system.
SHIM AND PLUMB UNITS AS REQUIRED BY OTHERS.
Attach unit to wall construction with nails or screws at each pre-punched hole in the installation fin.
PELLA WINDOW AND DOOR INSTALLATION SEALANT AND WATER RESISTANT BACKER ROD. Apply continuous sealant according to label directions and ASTM C1193.
Low expansion, low pressure polyurethane insulating window and door foam sealant - (DO NOT use high pressure or latex foams)
Apply a continuous 1" bead of insulating foam to provide a full interior seal.
Items in bold are available from Pella.
These details are for typical single punch openings. See Composite and Combinations for multiple-unit considerations.
See page 3 in this section for typical sealant details.
Refer to the appropriate Pella Impervia installation instruction for step by step instructions.
Scale 3" = 1' 0"
Integral Nailing Fin With Siding
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-5
Impervia® Installation Details
Items in bold are available from Pella.
These details are for typical single punch openings. See Composite and Combinations for multiple-unit considerations.
See page 3 in this section for typical sealant details.
Refer to the appropriate Pella Impervia installation instruction for step by step instructions.
Scale 3" = 1' 0"
WATER RESISTANT BARRIER BY OTHERSContinuous water-resistive barrier attached to the wall sheathing.
FLASHING BY OTHERSMetal head flashing.
SMARTFLASH® INSTALLATION TAPEIntegrate the window and door flashing tape into the wall system.
SHIM AND PLUMB UNITS AS REQUIRED BY OTHERS.
Attach unit to wall construction with nails or screws at each pre-punched hole in the installation fin.
PELLA WINDOW AND DOOR INSTALLATION SEALANT AND WATER RESISTANT BACKER ROD. Apply continuous sealant according to label directions and ASTM C1193.
Low expansion, low pressure polyurethane insulating window and door foam sealant - (DO NOT use high pressure or latex foams)
Apply a continuous 1" bead of insulating foam to provide a full interior seal.
Offset Nailing Fin With Flat Wood Trim
FRAM
E
RO
UG
H O
PEN
ING
[6]
1/4"
FRAM
E
RO
UG
H O
PEN
ING
[6]
1/4"
RO
UG
H O
PEN
ING
FRAM
E[6
]1/
4"
HEAD
JAMB
SILL
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-6
Impervia® Installation Details
WATER RESISTANT BARRIER BY OTHERSContinuous water-resistive barrier attached to the wall sheathing.
SMARTFLASH® INSTALLATION TAPEIntegrate the window and door flashing tape into the wall system.
Attach unit to wall construction with nails or screws at each pre-punched hole in the installation fin.
Pella Window and Door Installation Sealant and water resistant backer rod. Apply continuous sealant according to label directions and ASTM C1193.
Low expansion, low pressure polyurethane insulating window and door foam sealant - (DO NOT use high pressure or latex foams)
Apply a continuous 1" bead of insulating foam to provide a full interior seal.
THROUGH-WALL CAVITY FLASHING WITH WEEPS AT HEAD AND SILL BY OTHERS.
Scale 3" = 1' 0"
Items in bold are available from Pella.
These details are for typical single punch openings. See Composite and Combinations for multiple-unit considerations.
See page 3 in this section for typical sealant details.
Refer to the appropriate Pella Impervia installation instruction for step by step instructions.
Integral Nailing Fin With Brick Veneer
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-7
Impervia® Installation Details
WATER RESISTANT BARRIER BY OTHERSContinuous water-resistive barrier attached to the wall sheathing.
SMARTFLASH® INSTALLATION TAPEIntegrate the window and door flashing tape into the wall system.
Attach unit to wall construction with nails or screws at each pre-punched hole in the installation fin.
Pella Window and Door Installation Sealant and water resistant backer rod. Apply continuous sealant according to label directions and ASTM C1193.
Low expansion, low pressure polyurethane insulating window and door foam sealant - (DO NOT use high pressure or latex foams)
Apply a continuous 1" bead of insulating foam to provide a full interior seal.
Scale 3" = 1' 0"
Items in bold are available from Pella.
These details are for typical single punch openings. See Composite and Combinations for multiple-unit considerations.
See page 3 in this section for typical sealant details.
Refer to the appropriate Pella Impervia installation instruction for step by step instructions.
Integral Nailing Fin With Southwest-Style Hardcoat, Stucco On Insulation Board
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-8
Impervia® Installation Details
WATER RESISTANT BARRIER BY OTHERSContinuous water-resistive barrier attached to the wall sheathing.
FLASHING BY OTHERSMetal head flashing.
SMARTFLASH® INSTALLATION TAPEIntegrate the window and door flashing tape into the wall system.
SHIM AND PLUMB UNITS AS REQUIRED BY OTHERS.
Attach unit to wall construction with nails or screws at each pre-punched hole in the installation fin.
Pella Window and Door Installation Sealant and water resistant backer rod. Apply continuous sealant according to label directions and ASTM C1193.
Low expansion, low pressure polyurethane insulating window and door foam sealant - (DO NOT use high pressure or latex foams)
Apply a continuous 1" bead of insulating foam to provide a full interior seal.
Scale 3" = 1' 0"
Items in bold are available from Pella.
These details are for typical single punch openings. See Composite and Combinations for multiple-unit considerations.
See page 3 in this section for typical sealant details.
Refer to the appropriate Pella Impervia installation instruction for step by step instructions.
Integral Nailing Fin With Vinyl Siding
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-9
Impervia® Installation Details
WATER RESISTANT BARRIER BY OTHERSContinuous water-resistive barrier attached to the wall sheathing.
FLASHING BY OTHERSMetal head flashing.
SMARTFLASH® INSTALLATION TAPEIntegrate the window and door flashing tape into the wall system.
SHIM AND PLUMB UNITS AS REQUIRED BY OTHERS.
INSTALLATION FIN 0C9Q
Attach unit to wall construction with nails or screws at each pre-punched hole in the installation fin.
Pella Window and Door Installation Sealant and water resistant backer rod. Apply continuous sealant according to label directions and ASTM C1193.
Low expansion, low pressure polyurethane insulating window and door foam sealant - (DO NOT use high pressure or latex foams)
Apply a continuous 1" bead of insulating foam to provide a full interior seal.
Sill Support by others.
Scale 3" = 1' 0"
Items in bold are available from Pella.
These details are for typical single punch openings. See Composite and Combinations for multiple-unit considerations.
See page 3 in this section for typical sealant details.
Refer to the appropriate Pella Impervia installation instruction for step by step instructions.
Block Frame with Applied Nailing Fin, Sliding Door With Siding
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-10
Impervia® Installation Details
THROUGH-WALL CAVITY FLASHING WITH WEEPS AT HEAD AND SILL BY OTHERS.
SHIM AND PLUMB UNITS AS REQUIRED BY OTHERS.
INSTALLATION FIN 0C9Q
Attach unit to wall construction with nails or screws at each pre-punched hole in the installation fin.
Pella Window and Door Installation Sealant and water resistant backer rod. Apply continuous sealant according to label directions and ASTM C1193.
Low expansion, low pressure polyurethane insulating window and door foam sealant - (DO NOT use high pressure or latex foams)
Apply a continuous 1" bead of insulating foam to provide a full interior seal.
Scale 3" = 1' 0"
Items in bold are available from Pella.
These details are for typical single punch openings. See Composite and Combinations for multiple-unit considerations.
See page 3 in this section for typical sealant details.
Refer to the appropriate Pella Impervia installation instruction for step by step instructions.
Block Frame with Applied Nailing Fin, Sliding Door With Brick Veneer
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-11
Impervia® Installation Details
WATER RESISTANT BARRIER BY OTHERSContinuous water-resistive barrier attached to the wall sheathing.
FLASHING BY OTHERSMetal head flashing.
SMARTFLASH® INSTALLATION TAPEIntegrate the window and door flashing tape into the wall system.
SHIM AND PLUMB UNITS AS REQUIRED BY OTHERS.
INSTALLATION FIN 0C9Q
Attach unit to wall construction with nails or screws at each pre-punched hole in the installation fin.
Pella Window and Door Installation Sealant and water resistant backer rod. Apply continuous sealant according to label directions and ASTM C1193.
Low expansion, low pressure polyurethane insulating window and door foam sealant - (DO NOT use high pressure or latex foams)
Apply a continuous 1" bead of insulating foam to provide a full interior seal
Sill Support by others.
Scale 3" = 1' 0"
Items in bold are available from Pella.
These details are for typical single punch openings. See Composite and Combinations for multiple-unit considerations.
See page 3 in this section for typical sealant details.
Refer to the appropriate Pella Impervia installation instruction for step by step instructions.
Block Frame with Applied Nailing Fin, Sliding Door With Southwest-Style Hardcoat
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-12
Impervia® Installation Details
WATER RESISTANT BARRIER BY OTHERS
Continuous water-resistive barrier attached to the wall sheathing.
FLASHING BY OTHERS
Metal head flashing.
SMARTFLASH® INSTALLATION TAPE
Integrate the window and door flashing tape into the wall system.
SHIM AND PLUMB UNITS AS REQUIRED BY OTHERS.
INSTALLATION FIN 0C9Q
Attach unit to wall construction with nails or screws at each pre-punched hole in the installation fin.
PELLA WINDOW AND DOOR INSTALLATION SEALANT AND WATER RESISTANT BACKER ROD. Apply continuous sealant according to label directions and ASTM C1193.
Low expansion, low pressure polyurethane insulating window and door foam sealant - (DO NOT use high pressure or latex foams)
Apply a continuous 1" bead of insulating foam to provide a full interior seal.
Sill Support by others.
Scale 3" = 1' 0"
Items in bold are available from Pella.
These details are for typical single punch openings. See Composite and Combinations for multiple-unit considerations.
See page 3 in this section for typical sealant details.
Refer to the appropriate Pella Impervia installation instruction for step by step instructions.
Block Frame with Applied Nailing Fin, Block Frame Sliding Door With Vinyl Siding
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-13
Impervia® Installation Details
When To Use Subsill and Receptor Installation Method
• When there is no place to fold out a fin for nailing. • In applications where construction sequence dictates units be installed from the interior, or after the wall system is completely constructed.
Or in multi-story buildings requiring installation from the interior or when a more robust installation method is desired.
Products Available for this Installation
All Pella® Impervia® windows.
Important Installation Procedures
• Install receptor system in the opening plumb, level and square. • Provide a primary and secondary air and water seal around the perimeter of the unit. • Primary Seal—Seal the subsill and receptor to the exterior finish material. • Secondary Seal—Provide an interior seal around the perimeter of the unit by applying a 1" deep bead of Low expansion, low pressure
polyurethane insulating window and door foam sealant - (DO NOT use high pressure or latex foams). • Clips must be attached to receptor. Wall framing around window opening must also be adequate to withstand wind loads transferred from
window combination assembly. • Suggested unit setback is intended as good construction practice to protect window products from water cascading down building facade.
Setback must also take into consideration adequate sealant adhesion to the brick veneer. • See the Installation Accessories section for anchor clip spacing. • Commercial and / or large complex combination assemblies may require additional installation design considerations and attachments. See
the Combination Recommendations section.
NOTES
• Details shown are not intended to reflect complete installation procedures, but do reflect basic installation concepts. • This method is applicable for installation of Pella windows only. Pella warranty does not recommend use with other manufacturers' products. • See your local Pella sales representative for installation instructions.
General Notes on Subsill and Receptor Installation
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-14
Impervia® Installation Details
MAS
ON
RY
OPE
NIN
G
SILL
[3]
1/8"
MAS
ON
RY
OPE
NIN
G
SUB
FRAM
E
[19]
3/4"
FRAM
E
[10]
3/8"
SEAL
ANT [3
]1/
8"
MAS
ON
RY
OPE
NIN
G
SUB
FRAM
E
[19]
3/4"
FRAM
EJAMB
[25]1"
SUB
SILL
FRAM
E
[6]
1/4"
[6]
1/4"
SEAL
ANT
[10]
3/8"
SEAL
ANT
HEAD
Scale 3" = 1' 0"
Items in bold are available from Pella.
These details are for typical single punch openings. See Composite and Combinations for multiple-unit considerations.
See page 3 in this section for typical sealant details.
Refer to the appropriate Pella Impervia installation instruction for step by step instructions.
L-Receptor, Block Frame Casement with Steel Studs and Brick Veneer
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-15
Impervia® Installation Details
When to Use Block Frame Installation Method
• When there is no place to attach a fin.• In applications when construction sequence dictates units be installed from the interior, or after the wall system is completely constructed.• When Pella subsill accessories are used.
Products Available for this Installation
All Pella Impervia windows and doors.
Important Installation Procedures
• Shim unit in the opening plumb level and square. • Provide a primary and secondary air and water seal around the perimeter of the unit.• Primary Seal—Seal the unit to the exterior finish material.• Secondary Seal—Provide an interior seal around the perimeter of the unit by applying a 1" deep bead of low expansion, low pressure
polyurethane insulating window and door foam sealant - (DO NOT use high pressure or latex foams)• Seal wall cavity around perimeter of unit.• Clips must be attached to wall framing with anchors adequate for design pressure specified. Wall framing around window opening must also
be adequate to withstand windloads transferred from window composite. • Suggested unit setback is intended as good construction practice to protect window products from water cascading down building facade.
Setback must also take into consideration adequate sealant adhesion to the brick veneer. • See page 3 of this section for anchor clip spacing.• Commercial and / or large complex composites may require additional installation design considerations and attachments. See Composite
section.• See page 2 in this section for typical sealant placement details.
Notes
• Details shown are not intended to reflect complete installation procedures, but do reflect basic installation concepts. • Details show various wall systems with different Pella Impervia products. Details with other Pella Impervia products in the same wall
construction should be similar.
General Notes On Clip Installation
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-16
Impervia® Installation Details
RIGID INSULATION BY OTHERS.
THROUGH-WALL CAVITY FLASHING WITH WEEPS AT HEAD AND SILL BY OTHERS.
SMARTFLASH® INSTALLATION TAPE
SHIM AND PLUMB UNITS AS REQUIRED BY OTHERS.
INSTALLATION CLIPS #0CCJ
Place into fin groove and anchor to wall construction. Ensure that the interior bead of insulating foam continues around clips.
PELLA WINDOW AND DOOR INSTALLATION SEALANT AND WATER RESISTANT BACKER ROD. Apply continuous sealant according to label directions and ASTM C1193.
Low expansion, low pressure polyurethane insulating window and door foam sealant - (DO NOT use high pressure or latex foams)
Apply a continuous 1" bead of insulating foam to provide a full interior seal.
Scale 3" = 1' 0"
Items in bold are available from Pella.
These details are for typical single punch openings. See Composite and Combinations for multiple-unit considerations.
See page 3 in this section for typical sealant details.
Refer to the appropriate Pella Impervia installation instruction for step by step instructions.
Clip installation, Block Frame Sliding Window, Concrete Block and Brick Veneer
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-17
Impervia® Installation Details
RIGID INSULATION BY OTHERS.
THROUGH-WALL CAVITY FLASHING WITH WEEPS AT HEAD AND SILL BY OTHERS.
SMARTFLASH® INSTALLATION TAPE
SHIM AND PLUMB UNITS AS REQUIRED BY OTHERS.
INSTALLATION CLIPS #0CCJ
Place into fin groove and anchor to wall construction.
Scale 3" = 1' 0"
Items in bold are available from Pella.
These details are for typical single punch openings. See Composite and Combinations for multiple-unit considerations.
See page 3 in this section for typical sealant details.
Refer to the appropriate Pella Impervia installation instruction for step by step instructions.
PELLA WINDOW AND DOOR INSTALLATION SEALANT AND WATER RESISTANT BACKER ROD. Apply continuous sealant according to label directions and ASTM C1193.
Low expansion, low pressure polyurethane insulating window and door foam sealant - (DO NOT use high pressure or latex foams)
Apply a continuous 1" bead of insulating foam to provide a full interior seal. Ensure that the interior bead of insulating foam continues around the clip.
Clip installation, Block Frame Sliding Door, Concrete Block and Brick Veneer
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-18
Impervia® Installation Details
[52]
2 1/
16"
FRAM
E H
EIG
HT
[6]
1/4"
[6]
1/4"
FRAM
E H
EIG
HT
[6]
1/4"
RO
UG
H O
PEN
ING
[6]
1/4"
FRAM
E H
EIG
HT
FRAM
E H
EIG
HT
[6]
1/4"
RO
UG
H O
PEN
ING
[33]
1 5/
16"
[6]
1/4"
[40]
1 9/
16"
FRAM
E W
IDTH
RO
UG
H O
PEN
ING
[6]
1/4"
FRAM
E W
IDTH
[52]
2 1/
16"
HEAD
SILL
JAMB
Scale 3" = 1' 0"
Items in bold are available from Pella.
These details are for typical single punch openings. See Composite and Combinations for multiple-unit considerations.
See page 3 in this section for typical sealant details.
Refer to the appropriate Pella Impervia installation instruction for step by step instructions.
Clip installation, Block Frame Single-Hung, Aluminum Frame Expanders and Brickmould
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-19
Impervia® Installation Details
When to Use Block Frame pocket Installation Method
• In applications when windows are being replaced without full frame removal.
Products Available for this Installation
All Pella Impervia windows and doors.
Important Installation Procedures
• Shim unit in the opening plumb level and square. • Provide a primary and secondary air and water seal around the perimeter of the unit.• Primary Seal—Seal the unit to the exterior finish material.• Secondary Seal—Provide an interior seal around the perimeter of the unit by applying a 1" deep bead of low expansion, low pressure
polyurethane insulating window and door foam sealant - (DO NOT use high pressure or latex foams)• Seal wall cavity around perimeter of unit.
Notes
• Details shown are not intended to reflect complete installation procedures, but do reflect basic installation concepts. • Details show various wall systems with different Pella Impervia products. Details with other Pella Impervia products in the same wall
construction should be similar.
General Notes Pocket Installation
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-20
Impervia® Installation Details
HEAD
JAMB
SILL
FRA
ME
[6]
1/4"
FRA
ME
FRA
ME
[6]
1/4"
NOTE:
WALL CONSTRUCTION AND OLD DOUBLE-HUNG FRAME SHOWN ARE EXISTING; OLD DOUBLE-HUNG SASH HAS BEEN REMOVED.
REFER TO THE APPROPRIATE PELLA INSTALLATION INSTRUCTION FOR COMPLETE STEP BY STEP INSTRUCTIONS.
SHIM AND PLUMB UNITS AS REQUIRED.
SMARTFLASH® INSTALLATION TAPE
DOUBLE-HUNG SILL-ADAPTER 0A9U
PELLA WINDOW AND DOOR INSTALLATION SEALANT. Apply continuous sealant according to label directions and ASTM C1193.
SEAL THE UNIT TO EXISTING STOOL AND WINDOW SILL.
Low expansion, low pressure polyurethane insulating window and door foam sealant - (DO NOT use high pressure or latex foams)
Apply a continuous 1" bead of insulating foam to provide a full interior seal.
Pocket Installation Block Frame Double-Hung
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-21
Impervia® Installation Details
50EAL-RECEPTOR CLIP
50EBSUB FRAME
INSTALLATION TAPE
Use W/ #0C2B Fin#01JY
HEAD DRIP CAP [152]6"
[152]6"
[18]
11/1
6"
[19]
3/4"
[19]
3/4"
®
#0CFV(FOIL BACKED BUTYL)
SmartFlash INSTALLATION TAPE
[16]5/8"
#01E0WOOD RECEPTOR
CASEMENT/AWNING
[14]9/16"
[6]1/4"
[19]
3/4"
[16]
5/8" [124]
4 7/8"
[16]
5/8" [73]
2 7/8"
#0DTAEXTENSION
6-9/16" WOOD
#0DTAEXTENSION
4-9/16" WOOD
#0DTBWOOD RECEPTOR
#0DTD1/4" EXTENSION
JAMB EXTENSIONS
Use W/ #0C9Q Fin#0CCL
HEAD DRIP CAP
DRIP CAP / INSTALLATION FINS
[18]
11/1
6"
#0CCJCLIP
[406]16" O.C.
[165
]6
1/2"
[4
06]
16" O
.C.
[152
]6"
#0DTESILL ADAPTERDOUBLE HUNG
#0C2CSILL ADAPTERSINGLE-HUNG
#0CCJ
INSTALLATION CLIP
#0C2B7/8" OFFSET
#0C9QSTANDARD
SILL ACCESSORIES
[166]6 1/2"
INSTALLATION CLIP SPACING
Perimeter clip spacing to be 6" (152 mm) from the edge of each unit and 6" (152 mm) from both sides of a joining mullion. Typical spacing: 16" (457 mm) O.C. Each clip will hold 100 lbs. if attached with anchors that will hold 100 lbs.
Accessory Indiv. Part No.
Box No.
Single-Hung Sill Adapter 0A5Y 0C2C
Double-Hung Sill Adapter 0A9U 0DTE
3"-Wide SmartFlash® Installation Tape (150' rolls)
850H0000 0CFV
6"-Wide SmartFlash® Installation Tape (50' rolls)
850H0004 01FM
1/4" Jamb Extension 50CJ 0DST
Jamb Extension Wood Receptor 763R 0DTB
Casement/Awning Wood Receptor
80SC 01E0
4-9/16" Wood Jamb Extensions 3113 0DTA
6-9/16" Wood Jamb Extensions 310V 0DTA
Head Drip Cap for use with Standard Fin
0A5S 0CCL
Head Drip Cap for use with 7/8" Offset Fin
70Z2 01JY
Installation Fin Standard 761H 0C9Q
Installation Fin 7/8" Offset 762G 0C2B
Installation Clip 710L 0CCJ
Installation Accessories
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-22
Impervia® Installation Details
(1) For use with Casement/Awning exterior and Single-Hung, Fixed Window and Sliding Window interior.
(2) For use with Single-Hung, Fixed Window and Sliding Window exterior.
Accessory Indiv. Part No.
Box No.
I-Bar Joining Mullion 0A4S 0CCH
Foam Tape 830W 0CDZ
Mullion Foam Plugs — 0C2D
Horizontal Exterior Mullion cover 764H 0ESM
Mullion Extrusions — 0DSQ
Fin End Anchor 520D 0DSK
Flange Mullion Cover 0ALT 01K4
Standard Mullion Cover 7217 01K5
Split Mullion Plate 208Q, 209K 01E2
3/8” Mullion Plate 80ZT 01JV
Impervia SPD Fixed Panel Mull Kit 80UV 00Q7
Installation Accessories
[203]8"
[3]3/32"
[3]
3/32
"
[9]
3/8"
#00Q7
#01PG
[2]
1/16
"
[3]3/32"
[2]1/16"
SLIDING PATIO DOOR
[23]
15/1
6"[3
]3/
32"
[203]8"
[9]
3/8"
[2]
1/16
"
[2]1/16"
D2
D3
D1
D3
D4
D4D3D2D1
[12]1/2"
& FIXED FRAMESLIDING WINDOW / FIXED WINDOW
SINGLE-HUNG / DOUBLE-HUNG /
#01JXSEAL - 30' ROLL
MULLION BUTYL TAPE
(1) (2)
[9]
3/8" [8]
5/16"
#01K5STANDARD
[127]5"
[32]
1 1/
4"
[10]3/8"
[18]
11/1
6"
#01K4FLANGE
[13]1/2"
[6]
1/4" [43]
1 11/16"
#0ESMCOVER WITH WEEPS
HORIZONTAL EXTERIOR
#0ESJTRANSOM COVERINTERIOR DOOR
[57]2 1/4"
[43]
1 11
/16"
[7]
5/16
"
DIRECT MULLION ACCESSORIES
0C2DPLUG
MULLION FOAM
#0DSQEXTRUSIONS
MULLION
REINFORCING MULLION - TRANSOM Over SLIDING DOOR
#0DSKEND ANCHOR
#0CDZFOAM TAPE
#0CCHMULLION
I-BAR JOINING
AWNING / CASEMENT
DOOR MULLING PLATE
WINDOW MULLING PLATES
Interior Plate
Exterior PlateExterior Plate
Interior Plate#01JV
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-23
Impervia® Installation Details
Accessory Indiv. Part No.
Box No.
Head Drip Cap for use with Standard Fin 0A5S 0CCLHead Drip Cap for use with 7/8" Offset Fin 70Z2 01JYMullion End Anchors - Block Frame 813G/813L 01NBMullion End Anchors - Standard Fin 813H 01NAMullion End Anchors - Offset Fin 813J 01NCMullion Splice - for 3" Frame Depth 813P 01N8Mullion Splice - for 3-1/4" Frame Depth 813A 01N91/2" Reinforcement Mullion 135L 01PKExterior Mullion cover 736M 01N5Interior Mullion Cover - for 3" Frame Depth 716T 01N7Interior Mullion Cover - for 3-1/4" Frame Depth 716S 01N6Outer Subsill 716Q 01NGInterior Subsill 50BP 01NFInterior Subsill Clip - for 3" Frame Depth 716R 01NJInterior Subsill Clip - for 3-1/4" Frame Depth 716P 01NKSubsill Endcap LH/RH 813K / 813M 01NL
Installation Accessories - 1/2" Mullion Reinforcing and Subsill
R3
1/2" Mullion Reinforcingwith Optional Subsill
1/2" Mullion Reinforcing
S3
R4
R6
R3
R5
R2
R2
S1
R5
R3
S2
R6
S3
R4
R2R1
[39]1 9/16"
[21]
13/1
6"
[33]1 5/16"
[14]
9/16
"[3
0]1
3/16
"
[23]7/8"
[14]
9/16
"[3
0]1
3/16
"
[6]1/4"
S3
S2S1
R5 R6
R4R3
R2
R1
MULLION COVEREXTERIOR
ALL SUBSILL KITS#01NL
ALL SUBSILL KITS#01NL
HEAD DRIP FIN
[30]
1 3/
16"
[24]15/16"
[24]15/16"
[30]
1 3/
16"
3 1/4" KIT #01N3, #01N4#01NK
3" KIT #01N1, #01N2#01NJ
[83]3 1/4"
[25]1"
KITS #01MX, #01N0#01JY
KITS #01MV, 01MY#0CCL
INTERIOR CLIP
#01MV, #01MX3" KIT #01N6
#01MY, #01N03 1/4" KIT
#01N7
[21]
13/1
6"
[31]
1 3/
16"
INTERIOR MULLION COVERS
ALL SUBSILL KITSOUTER #01NG / INNER #01NF
[22]
7/8"
[76]3"
[13]
1/2"
MULLION1/2" REINFORCEMENT
ALL MULLION KITS#01PK
[39]1 9/16"
3" KIT #01MV, 01MX#01N8
[21]
13/1
6"
KIT #01MX#01NC
OFFSET FIN
3 1/4" KIT #01MY, 01N0#01N9
MULLION SPLICES
ALL MULLION KITS#01N5
SUBSILL
KIT #01MV#01NA
STANDARD FIN
KIT #01MW#01NB
BLOCK FRAME
LEFT END CAP
MULLION END ANCHORS
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-24
Impervia® Installation Details
Installation Accessories
[25]1"
[52]
2 1/
16"
[25]1"
[67]2 5/8"
[117
]4
5/8"
[25]1"
[56]
2 1/
4"
[7]
1/4"
[67]2 5/8"
[89]
3 1/
2"
[67]2 5/8"
[24]
15/1
6"
[17]11/16"
50EAL-RECEPTOR CLIP
50EBSUB FRAME
(3)0APM2" STRUCTURERECEPTOR for(3)
0APJT-RECEPTOR
and RECEPTORSCUSTOM ORDER MULLION COVERS
[25]1"
[6]1/4"
(3)
(3)(3)
[14]
9/16
" [6]1/4"
71YZL-RECEPTOR
71YYOFF SET
71YXOFF SET
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-25
Impervia® Installation Details
• 1. Attach 1" mullion reinforcements with end anchors.• 2. Can be used either horizontally or vertically for wind
load mullion reinforcement. • 3. Do not use as part of building structure.• 4. Contact PASS for wind load information.
CONTINUOUS SEALANT BY OTHER
Refer to Installation Instructions for Installation
anchor schedule and sealant application
3" and 4-1/4" Tube mullion
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-26
Impervia® Installation Details
Factory Supplied Frame Expander Kits
These kits are factory cut and notched to fit each side of a Pella aluminum clad or Pella Impervia products with accessory groove. The ends are prepped for overlapping butt joints which allows installers to leave the 90 degree overlap or field-cut a mitered corner.
• Maximum size is 144" x 144"
• Trim comes processed and notched to length per unit configuration.
• Notches begin at the outside of the frame and tails are longer to accommodate unit and combination growth tolerances.
• No need to calculate the number of lineals a job will require and saves time and scrap on the job site.
• Available on all Aluminum Clad products, Impervia products and entry doors, including curved and angled shapes.
� Curved Shapes – Frame expander with Receptor Kits will not be available for shapes that include curves. Frame expander (without receptor) kits will be available for most curved and angled shapes. (Curved frame expander with receptor is still available - just not in this configured kit).
� Angled Shapes – Frame expander and Frame expander with receptor kits are available for most angled shapes. Receptors are cut long to accommodate field miters.
� Overlapping Frame Expanders - No kits will be available with overlapping curved frame expanders.
� Pella Impervia – Fits both the fiberglass and aluminum clad accessory grooves.
Installation Accessories - Exterior Trim
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-27
Impervia® Installation Details
47D36"
47E34"
47D62 1/2"
47D51 3/4"
47D41"
[30]
1 3/
16"
[49]
1 15
/16"
[68]
2 11
/16"[1
08]
4 1/
4"
[152
]6"
FRA
ME
[10]
3/8"
[10]
3/8"
[95]
3 3/
4"R
OU
GH
OP
EN
ING
MA
SO
NR
Y O
PE
NIN
G
FRA
ME
[10]
3/8"
[10]
3/8"
[95]
3 3/
4"R
OU
GH
OP
EN
ING
MA
SO
NR
Y O
PE
NIN
GM
AS
ON
RY
OP
EN
ING
RO
UG
H O
PE
NIN
G
[10]
3/8"
FRA
ME
Frame Expander
Custom Brickmould with Clip
[30]
1 3/
16"
[22]
7/8"
[37]
1 1/
2"[3
7]1
1/2"[27]
1 1/
16"
[27]
1 1/
16"
[43]
1 11
/16"
[48]
1 7/
8"
[33]
1 5/
16"
[48]
1 7/
8"
[52]
2 1/
16"
[57]2 1/4"
[36]1 7/16"
[23]15/16"
[16]5/8"
[41]1 5/8"
[38]
1 1/
2"
[38]1 1/2"
72AN - 72AQ2 1/16"
72AP - 72AQ1 7/8"
7SB1 - 0SBQ1 5/16"
7SBP - 0SBN1 7/8"
7SBX - 0SBN1 11/16"
7SB7 - 0SB81 1/2"
SILL
JAMB
HEAD
Scale 3" = 1' 0"
Application: New Construction or Renovation
• Provides the look of flat trim• Receptor available for wide trims• Paint finish that matches windows• Available with or without brickmould• Custom brickmould profiles available• Straight or curved• Trim to frame opening• Factory Supplied Frame Expander Kits available,
trim is processed and notched to length per unit configuration, saves time and scrap on the job site.
[32]
1 1/
4"
[27]1 1/16"
[8]5/16"
FRAME EXPANDER RECEPTOR
[13]
1/2"
6" Frame Expander
4" Frame Expander
2 1/2" Frame Expander
1 3/4" Frame Expander
1" Frame Expander
[30]
1 3/
16"
[49]
1 15
/16"
[68]
2 11
/16"
[108
]4
1/4"
[152
]6"
required.into blocking. Return leg can be field-trimmed asexpander as an alternate to face-screwing edgeUsed to receive and trim outside edge of frame
Used at head, jamb and/or sill.
Exterior Trim - Aluminum Brickmould
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-28
Impervia® Installation Details
[16]5/8"
[19]3/4"
[19]3/4"
[19]3/4"
[19]3/4"
[64]
2 1/
2"
[64]
2 1/
2" [89]
3 1/
2"
[89]
3 1/
2"
[83]
3 1/
4"
[83]
3 1/
4"
[64]
2 1/
2"
[64]
2 1/
2"
[64]
2 1/
2"
[64]
2 1/
2"
[64]
2 1/
2"
[89]
3 1/
2"
[89]
3 1/
2"
[70]
2 3/
4"
[64]
2 1/
2"
[19]3/4"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[16]5/8"
[83]
3 1/
4"
[11]7/16"
[16]5/8"
[108
]4
1/4"
[64]
2 1/
2" [89]
3 1/
2"
[57]
2 1/
4" [70]
2 3/
4"
[76]3"
[89]
3 1/
2"
[83]
3 1/
4"
[76]3"
[64]
2 1/
2"
[16]5/8"
[89]
3 1/
2"
[16]5/8"
[83]
3 1/
4"[5
7]2
1/4"
[64]
2 1/
2"
30AX, 30BB2 1/2" 1
30NY2 1/2" 3
30NX, 312Q2 1/2" 2
31TY2 1/2" 4
31TZ2 1/2" 5
31U02 1/2" 6
31U23 1/4" 1
30AZ, 312R3 1/2" 1
30NW, 312S3 1/2" 2
31U43 1/2" 3
31U53 1/2" 4
31U63 1/2" 5
31UB3 1/4" 1
31UC3 1/4" 2
31UD3 1/4" 3
31UE3 1/2" 2
30BA3 1/2" 1
30AY, 30BD2 1/2" 1
31U72 1/2" 2
31UF2 1/2" 3
31UA3" 1
31U93 1/4" 1
30U7, 30UA3 1/2" 1
31U83 1/2" 2
31UN4 1/4" 1
31UM3 1/2" 1
31UH3" 2
31UG3" 1
31U12 3/4" 2
31UL2 3/4" 1
31UK2 1/2" 2
31UJ2 1/2" 1
31UP2 1/4" 1
31U32 1/4" 1
PROVINCIAL
CRAFTSMAN
RANCH
COLONIAL
Interior Casing
Pella 2020 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com F-ID-29
Impervia® Installation Details
[19]3/4"
[19]3/4"
[19]3/4"
[19]3/4"
[9]5/16"
[45]
1 25
/32"[6]
1/4"
[29]
1 5/
32"
[3]
1/8"
[13]
1/2"
[3]
1/8"
[13]
1/2"
[3]
1/8"
[13]
1/2"
[3]
1/8"
[16]
5/8"
[16]
5/8"
[13]
1/2"
[16]
5/8"
[16]
5/8"
[6]1/4"
[129
]5
1/8"
[6]1/4"
[91]
3 5/
8"[6]1/4"
[36]
1 3/
8"
[6]1/4"
[6]1/4"
[6]1/4"
[6]1/4"
[6]1/4"
[6]1/4"
[6]1/4"
[6]1/4"
[16]
5/8"
[16]5/8"
[16]5/8"
[16]
5/8"
[10]
3/8"
[67]2 5/8"
[67]2 5/8"
[113]4 7/16"
[41]1 5/8"
[41]1 5/8"
[113]4 7/16"
[62]2 7/16"
[41]1 5/8"
[41]1 5/8"
[62]2 7/16"
[32]
1 1/
4"
[41]1 5/8"
[16]
5/8"
[13]
1/2"
[19]
3/4"
[19]
3/4"
[12]
1/2"
[41]1 5/8"
[12]1/2"
[64]
2 1/
2"
[133
]5
1/4"
[16]5/8"
[35]1 3/8"
[47]1 13/16"
[22]7/8"
[44]1 3/4"
[22]7/8"
[16]
5/8"
[10]
3/8"
[129
]5
1/8"
[117
]4
5/8"
[104
]4
1/8"
[91]
3 5/
8"
[79]
3 1/
8"
[66]
2 5/
8"
[53]
2 1/
8"
[36]
1 3/
8"
31VWOgee 2
31VSOgee 2
30LCRound 2
3204Round 2
32WJOgee 1
31VROgee 1
32WHRound 1
3146Round 1
#2600DOUBLE-HUNG
#26A9CASEMENT
261CLattice 5
260PLattice 4
260ALattice 3
Jamb6 9/16"
Jamb4 9/16"
STOOL
COVE MOULDBASE TRIM
SPREAD MULLION COVER
LATTICE
STOP
261C4" Mullion 1
261B3 1/2" Mullion 1
260V3" Mullion 1
260P2 1/2" Mullion 1
260N2" Mullion 1
260D1 1/2" Mullion 1
260B1" Mullion 1
260A1/2" Mullion 1
30U5 / 30U8Quarter Round 1
31VVLattice 2
60U6 / 60U9Cove Trim 1
31VPLattice 1
31VQQuarter Round 2
31VLColonial 2
30VGColonial 4
31VFColonial 3
30VMColonial 1
30VJRound 1
31VHRound 2
31VKRanch 1
31VNSquare 1
Interior Trim