1. Mounting Instructions 2. Mounting Instructions ESE00163EN 2006-06 Indi Top Mounting Instruction 3. Mounting Instructions 9611-99-4624 4. Mounting Instructions 1. Setting up Indi Top (push button) 2. Setting up Indi Top (push button) Fix the magnet on top of the actuator Fit Indi Top over the magnet and the "mushrooms" - front opposite air fitting Carefully fix Indi Top with the two allen screws (max. torque 2,5 Nm), while pres- sing down. Connect wires as below: To enter SETUP press and hold "SP2" + "Enter" until the blue LED starts to flash (3 seconds) Clear previous saved positions by pressing "Enter" until all the LED's have turned ON in a sequence (blue-green-yellow) and flashed once (3 seconds) Note: Switch between PNP/NPN by connecting the brown wire to either +/L1 (PNP) or -/N (NPN) Plug Version: Pin connections 1: -/N ( ) 2: SP2 (Energized) 3: SP1 (De-energized) 4: +/L1 ( ), 8-30V DC/AC 5: Remote setup bit (if not used, connect to +/L1 (pin4)) Red: +/L1( ), 8-30V DC/AC Black: -/N ( ) Green: SP1 (De-energized) Yellow: SP2 (Energized) Brown: PNP (+ or L1)/NPN (- or N) Orange: Remote setup bit (If not used, connect to +/L1) Alfa Laval Kolding A/S, www.alfalaval.com 5 1 2 4 3

IndiTop - Alfa Laval · Fix the magnet on top of the actuator Fit IndiTop over the magnet and the "mushrooms" - front opposite air fitting Carefully fix IndiTop with the two allen

  • Upload
    others

  • View
    8

  • Download
    1

Embed Size (px)

Citation preview

Page 1: IndiTop - Alfa Laval · Fix the magnet on top of the actuator Fit IndiTop over the magnet and the "mushrooms" - front opposite air fitting Carefully fix IndiTop with the two allen

1. Mounting Instructions 2. Mounting Instructions

ES

E00

163E

N

2006

-06

Ind

iTo

p

Mou

ntin

g In

stru

ctio

n

3. Mounting Instructions

9611

-99-

4624

4. Mounting Instructions 1. Setting up IndiTop (push button) 2. Setting up IndiTop (push button)

Fix the magnet on top of the actuator Fit IndiTop over the magnet and the "mushrooms" - front opposite air fitting

Carefully fix IndiTop with the two allen screws (max. torque 2,5 Nm), while pres-sing down.

Connect wires as below: To enter SETUP press and hold "SP2" + "Enter" until the blue LED starts to flash (3 seconds)

Clear previous saved positions by pressing "Enter" until all the LED's have turned ON in a sequence (blue-green-yellow) and flashed once (3 seconds)

Note: Switch between PNP/NPN by connecting the brown wire to either +/L1 (PNP) or -/N (NPN)

Plug Version:Pin connections1: -/N ( )2: SP2 (Energized)3: SP1 (De-energized)4: +/L1 ( ), 8-30V DC/AC5: Remote setup bit (if not used, connect to +/L1 (pin4))

Red: +/L1( ), 8-30V DC/ACBlack: -/N ( )Green: SP1 (De-energized)Yellow: SP2 (Energized)Brown: PNP (+ or L1)/NPN (- or N)Orange: Remote setup bit (If not used, connect to +/L1)

Alfa

Lav

al K

old

ing

A/S

, ww

w.a

lfala

val.c

om

5

1 2

4 3

Page 2: IndiTop - Alfa Laval · Fix the magnet on top of the actuator Fit IndiTop over the magnet and the "mushrooms" - front opposite air fitting Carefully fix IndiTop with the two allen

3. Setting up IndiTop (push button) 4. Setting up IndiTop (push button)

De-energize the valve and save the 1st Set Point "SP1" (de-energized) by pressing the "SP1" button until "SP1" LED becomes steady ON (3 seconds)

Energize the valve and save the 2nd Set Point "SP2" (energized) by pressing the "SP2" button until "SP2" LED becomes steady ON (3 seconds)

5. Setting up IndiTop (push button)

To exit SETUP press and hold "SP2" + "Enter" until the blue LED becomes steady (3 seconds)

Verify the saved positions by energizing/ de-energizing the valve and see if the correct LED is lit (SP1 = de-energized, SP2 = energized)

6. Setting up IndiTop (push button)

7. S

ettin

g up

In

diT

op

(Rem

ote)

The

sequ

ence

in th

e flo

w c

hart

sho

wn

mus

t be

follo

wed

in th

e pr

ogra

mm

ing

to d

o a

succ

essf

ul re

mot

e se

tup.

No

te 1

The

rem

ote

setu

p ca

n be

don

e in

two

way

s: E

ither

by

a si

mpl

e P

LC p

rogr

am o

r by

man

ual b

it (ta

g) c

ontr

ol.

In b

oth

case

s, th

e flo

w c

hart

mus

t be

follo

wed

to e

nsur

e th

e rig

ht

feed

back

.

No

te 2

The

"Rem

ote

Set

up B

it" m

ust a

lway

s be

con

nect

ed to

+/L

1 if

the

rem

ote

setu

p fe

atur

e is

not

use

d.

Set point 1 (SP1) is intended to be the return position of the valve in case of a power breakdown, i.e. de-energized.

Set point 2 (SP2) is intended to be the opposite of SP1, i.e. energized.

Tech

nica

l Dat

a

Pro

tect

ion

Cla

ssIP

66/6

7

Pow

er S

upp

lyIn

diTo

p is

des

igne

d to

be

a pa

rt o

f the

PLC

's In

put/

Out

put (

I/O)

syst

em. I

t sho

uld

be s

uppl

ied

from

the

sam

e pr

otec

ted

pow

er

supp

ly a

s th

e ot

her I

/O d

evic

es. T

he u

nit i

s re

vers

e po

larit

y an

d sh

ort c

ircui

t pro

tect

ed. T

he p

ower

sup

ply

mus

t mee

t the

requ

ire-

men

ts o

f EN

611

31-2

.

Sup

ply

volta

ge: .

......

......

......

......

.8 -

30

V D

C/A

CS

uppl

y vo

ltage

nom

inal

: ....

......

...24

V D

C/A

C (R

MS

) (-1

5%/

+2

0% a

s pe

r EN

611

31-2

:200

3)M

ax. r

ippl

e: ..

......

......

......

......

......

5% o

f nom

inal

sup

ply

volta

geS

uppl

y vo

ltage

abs

olut

e m

ax: .

...30

V D

C/A

CS

uppl

y vo

ltage

abs

olut

e m

in.:

....8

V D

C/A

CS

uppl

y cu

rren

t*):

......

......

......

......

Max

. 45

mA

*) Th

e in

itial

cur

rent

dur

ing

pow

er-o

n is

hig

her.

The

actu

al s

hape

of

the

curr

ent p

ulse

dep

ends

on

the

pow

er s

uppl

y us

ed. T

ypic

al

valu

es a

re 1

50m

A R

MS

dur

ing

13 m

s (re

gula

ted

PS

) to

360

mA

R

MS

dur

ing

8 m

s (u

nreg

ulat

ed P

S).

The

fulfi

lling

of th

e U

L re

quire

men

ts in

UL5

08 re

quire

s th

at

the

unit

is s

uppl

ied

by a

n is

olat

ing

sour

ce c

ompl

ying

with

the

requ

irem

ents

for c

lass

2 p

ower

uni

ts (U

L131

0) o

r cla

ss 2

and

3

tran

sfor

mer

s (U

L158

5).

Feed

bac

k S

igna

lsO

utpu

t sig

nals

from

the

sens

or u

nit t

o th

e co

nnec

ted

digi

tal

inte

rface

(PLC

).N

omin

al v

olta

ge: .

......

......

......

......

.Sam

e as

sup

ply

volta

ge.

Load

cur

rent

:.....

......

......

......

......

...50

mA

typi

cally

, 100

mA

max

.Vo

ltage

dro

p: ...

......

......

......

......

.....

Typi

cally

3 V

at 1

00 m

A