LDPI, Inc. has been manufacturing fluorescent lights and commercial lighting since 1980. From that time, our product line has grown to cover a wide spectrum of applications. LDPI, Inc. has added fixtures from wet, harsh, hazardous and clean room applications, diversifying our specialized line of paint/powder booth fixtures.
Citation preview
APPLICATIONS:
TASK INDUSTRIALPAINT BOOTHVAPOR/DUSTWET/DAMPMARINEEXPLOSIONHID LIGHTINGINSPECTION
TOLL FREE:1-800-854-0021 • Fax: 715-839-8145 • Web: www.ldpi-inc.com
Lighting For hazardous Locations, industriaL & commerciaL appLications
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
www.ldpi-inc.com
LDPI BiographyProducts and Services:
LDPI, Inc., located in Eau Claire, Wisconsin, manufactures hazardous location fluorescent lighting fixtures. LDPI provides fixtures to the nation’s leading paint
booth manufacturers, electrical and paint distributors, and end users. LDPI manufactures a broad line of fluorescent lighting products to serve a wide variety
of markets from general industrial to specialized markets that require hazardous rated and explosion proof fluorescent lighting.
Markets:
LDPI serves a wide array of industries across the globe. LDPI’s roots in the paint finishing industry have contributed to expansion into other hazardous and
industrial applications. LDPI maintains active representation and distribution in the paint finishing, electrical and industrial lighting industries, in addition to
OEM and catalog markets.
Promotional Efforts:
LDPI maintains an aggressive integrated marketing strategy. Well trained sales engineers work with customers in each key market. LDPI employs the use
of trade journals, government publications and direct mailings to current and potential customers. We also seek out new markets through our business
development initiatives, the internet and trade shows. LDPI’s independent manufacturer representative network maintains a presence and awareness with
the small independent electrical distributors, as well as major electrical houses and niche market distributors. LDPI constantly evaluates its marketing efforts,
making enhancements as needed to increase its account penetration, sales and customer services.
In 1981 LDPI, Inc. was founded with a vision to manufacture quality lighting products for the paint spray booth manufacturing industry. Since that time, LDPI® has become a
recognized leader in that area and has expanded its original vision to include industrial and commercial lighting products. Based in Eau Claire, Wisconsin, LDPI designs, engineers
and manufactures its lighting products for applications ranging from hazardous locations and harsh environments to general industrial and facility lighting. LDPI’s lighting products
are utilized in both new construction and retrofit projects.
LDPI, Inc. has been manufacturing fluorescent lighting since the early 1980s. From that time, our product line has grown to cover a wide spectrum of
applications. LDPI has added fixtures for wet, harsh, hazardous and clean room applications, diversifying our line of paint/powder booth fixtures.
LDPI is committed to new product design and development, strategic partnership development and customer satisfaction.
COMPANY STATEMENTCOMPANY STATEMENTA B O U T L D P I , I N C .
LDPI, Inc.4404 Anderson DriveEau Claire, WI 54703Toll Free: 1-800-854-0021Fax: 715-839-8145Web: www.ldpi-inc.comE-mail: [email protected]
REV: 16JUL2012
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 20122
www.ldpi-inc.com
CONTENTSCONTENTSF I X T U R E S L I S T E D B Y S E R I E S
FIXTURES BY SERIES
222 SERIES (General Industrial) .................................... PAGE: 5
229H SERIES (General Industrial) ................................. PAGE: 7
236 SERIES (High Bay) ................................................. PAGE: 9
240 SERIES (Vapor/Dust) .............................................. PAGE: 11
240 8 Ft. SERIES (Vapor/Dust) ...................................... PAGE: 13
241 SERIES (Vapor/Dust) .............................................. PAGE: 15
260/261 SERIES (Vapor/Dust) ....................................... PAGE: 17
280/281 SERIES (Vapor/Dust) ....................................... PAGE: 19
SLIM LIGHT SERIES (Paint Booth) ............................... PAGE: 21
400 SERIES (Rear Access Vapor/Dust) ......................... PAGE: 23
440 T/THO SERIES (Troffer Vapor/Dust) ....................... PAGE: 25
440 2x4 SERIES (Troffer Vapor/Dust) ............................ PAGE: 27
376 SERIES (Wet/Damp) ............................................... PAGE: 29
379 SERIES (Wet/Damp) ............................................... PAGE: 31
379i SERIES (Wet/Damp) .............................................. PAGE: 33
380 SERIES (Explosion Proof) ....................................... PAGE: 35
381 SERIES (Vapor Proof) ............................................. PAGE: 39
383 SERIES (Explosion Proof Incandescent) ................ PAGE: 41
384 SERIES (Marine/Wet) .............................................. PAGE: 43
387 SERIES (CFL/HID Vapor Proof) .............................. PAGE: 45
INDUCTION SERIES ..................................................... PAGE: 47
HID H/H2 SERIES (Hazardous) ..................................... PAGE: 49
HID XP/XP2 SERIES (Explosion Proof) ......................... PAGE: 61
HID FL SERIES (Flood) .................................................. PAGE: 71
CFL SERIES (Compact Fluorescent) ............................. PAGE: 73
INSPECTION SERIES
INSPECTION SERIES ................................................... PAGE: 77
INSPECTION MOUNTING AND TUNNEL ..................... PAGE: 79
INS2 INSPECTION SERIES .......................................... PAGE: 81
PORTABLE LIGHTING
SINGLE TASK/INSPECTION CARTS ............................ PAGE: 83
TASK/INSPECTION CARTS .......................................... PAGE: 84
EXPLOSION PROOF CARTS ........................................ PAGE: 85
MOUNTING & PHOTOMETRICS
MOUNTING .................................................................... PAGE: 87BOOTH CORNER/HIP MOUNT ..................................... PAGE: 93PHOTOMETRICS ........................................................... PAGE: 99
LAMPS, BALLASTS & LENS PROTECTION
FLUORESCENT LAMPS ................................................ PAGE: 122H.I.D. LAMPS ................................................................ PAGE: 123INCANDESCENT LAMPS .............................................. PAGE: 123BALLASTS ..................................................................... PAGE: 124FIXTURE LENS PROTECTION ..................................... PAGE: 125
INFORMATION
HAZARDOUS LOCATION FUNDAMENTALS ................ PAGE: 126IP CODE ......................................................................... PAGE: 130CHEMICAL RESISTANCE ............................................. PAGE: 131LIGHT CALCULATION REQUEST FORM ..................... PAGE: 133INDOOR LIGHTING APPLICATION FORM ................... PAGE: 134PARKING GARAGE APPLICATION FORM ................... PAGE: 135RECOMMENDED LIGHT LEVELS ................................ PAGE: 136CUSTOM APPLICATIONS ............................................. PAGE: 137ASK THE EXPERT ......................................................... PAGE: 138SHIPPING INFORMATION ............................................ PAGE: 140GENERAL T & C OF SALE ............................................ PAGE: 141INDEX ............................................................................. PAGE: 144
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
www.ldpi-inc.com
3
* Access: R = Rear F = Front O = Open¤ For Class Definitions Reference Pages 126-129◊ Marine: # = Inside Drip Proof (UL 1598) ○= Outside Salt Water (UL 1598A)
SERIES ACCESS* General Corrosion Class I¤ Class I¤ Class II¤ Class III¤ Paint Wet Damp Marine◊ Battery PortableR F O Industrial Resistant Div. 1 Div. 2 Booth Damp Only Bkp
222 • •
229H • • •
236 • •
240 • • • • • • •
240 8 Ft. • • •
241 • • • • • •
260 • • • • • •
261 • • • • •
280 • • • • • •
281 • • • • •
Slim lights • • • •
400 • • • •
440 T/THO • • • •
440 2x4 • • • •
376 • • • • # •
379 • • • •
379i • • • • •
380 • • • • • • • ○ •
381 • •
383 • • • • • • • • #384 • • • • ○ •
387 • • #Induction • • • • •
HID H/H2 • • • • • ○HID XP/XP2 • • • • ○
HID FL • • • • ○CFL • • • ○
Inspection • • •
INS2 • •
Single Cart • •
Task Carts • •
XP Cart • • • • • • •
We use our best effort to make our catalog accurate. We reserve the right to correct typographical errors and omissions. Specifications may be changed subsequent to printing.
APPLICATION GUIDEAPPLICATION GUIDEL I S T E D B Y F I X T U R E S E R I E S
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 20124
www.ldpi-inc.com
ANSI American National Standards InstituteBX Box MountCSA Canadian Standards AssociationCED Canadian Electric CodeDOE Department of EnergyEPA Environmental Protection AgencyETL Electrical Testing LaboratoriesE.S. Electric StartH.I.D. High Intensity DischargeH.L.O. High Light OutputH.O. High OutputHPF High Power FactorHPS High Pressure SodiumHz HertzIEC International Electrotechnical CommissionIP Ingress ProtectionI.S. Instant StartmA MilliampsMH Metal HalideMV Mercury VaporNEC National Electric CodeNEMA National Electrical Manufacturer’s AssociationNFPA National Fire Protection AssociationNIST National Institute of Testing LaboratoriesNPT National Pipe ThreadNRTL National Recognized Testing LaboratoryNSF National Sanitation Foundation InternationalOEM Original Equipment ManufacturerOSHA Occupational Health and Safety AssociationPC PolycarbonateP.S. Program StartP/N Part NumberR.S. Rapid StartSJO 300-Volt Service Cord/Oil Resistant Outer JacketSO 600-Volt Service Cord/Oil Resistant Outer JacketTHD Total Harmonic DistortionUNV Universal VoltageUL Underwriters LaboratoryV VoltsW Watts
CATALOG ACRONYMSCATALOG ACRONYMSU S E D I N T H E L D P I , I N C . C ATA L O G
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
5
222 SERIES222 SERIESG E N E R A L I N D U S T R I A L L I G H T I N G
Assembly AreasGeneral Industrial
Task Lighting
GE
NE
RA
L I
ND
US
TR
IAL
LIG
HT
ING
Fabricated from pre-painted cold rolled steel, the 222 Series is ideal for industrial lighting needs. The 222 Series uses an optional 5 Ft. 3-wire whip which reduces installation time. Available in T8, T8HO or T5HO lamps. Lamps not included.
LISTINGS: UL 1598 listed U.S. and Canada
FEATURES: Open industrial fixture Sturdy 20 gauge steel housing Durable pre-painted white enamel finish Tool-less access for ease of maintenance.
ELECTRICAL: Utilizes 32, 44, and 54 Watt 4 Ft. lamps. Available in universal, 120, 277 and 347 volt electronic ballasts. (Other voltages available, consult factory)
OPTIONS: ALL OPTIONS ORDERED SEPARATELy PC: Post painted white powder coat EM: Emergency battery backup ballast 120 or 277V - MUST SPECIFY SR: Specular reflector SL: Slots for up-light NA: Narrow angle reflector WA: Wide angle reflector • MOUNTING KITS - ordered separately - see next page CH: Chain hanging kit CM: Cable mount kit
Fixture shown with optional wide reflector "WA"Standard Fixture
Fixture with Wide Angle Reflector "WA"Fixture with Narrow Angle Reflector "NA"Standard Fixture
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 20126
www.ldpi-inc.com
222 SERIES222 SERIESG E N E R A L I N D U S T R I A L L I G H T I N G
MOUNTING - ORDERED SEPARATELy
LAMPS SOLD SEPARATELy(Multiple voltages available, consult factory) (Consult factory for lead time on non-stock products.)
NOTE: T8HO is only available in a 2 lamp configuration8 Ft. lamp fixtures only available in 2 lamp configuration6 lamp and 8 lamp configuration only available in 8 Ft. fixtures
CAN SHIP VIA UPS
EM: Emergency battery back up ballastSL: Slots for uplightSR: Specular ReflectorPC: Powder Coat paint - whiteNA: Narrow Angle ReflectorWA: Wide Angle ReflectorCM: Cable Mount (incl. 5 Ft. cable)CH: Chain Hang Kit
UNV1: 120-277 Volt (T5HO & T8 only)120: 120 Volt277: 277 VoltUNV2: 347-480 Volt (T5HO only)
T5HO: 54WT8: 32WT8HO: 44W
LAMP TyPE
2L: (4 or 8 Ft. lamps)3L: (4 Ft. lamps)4L: (4 Ft. lamps T5 & T5HO only)6L: (4 Ft. lamps)8L: (4 Ft. lamps T5 & T5HO only)
LAMP QTy VOLTAGE OPTIONSLAMP LENGTH
4: 4 Ft.8: 8 Ft.
SERIES
222
HANGING BRACKETQTY (2)
5FT NO. 2LOOP HANGING CABLE
QTY (2)
HANGING BRACKETQTY (2)
24" JACKCHAINQTY (2)
CM: Cable mount hanger kitCH: Chain mount hanger kit
7 3/4"
3 1/2"
5 1/2"222-T5HO-2L-4-UNV1-NA
NARROW ANGLE REFLECTOR
5 1/2"
5 11/16"
1 13/16"
222-T5HO-2L-4-UNV1STANDARD BALLAST COVER
10"
5 1/2"
3 1/2"
222-T8-3L-4-UNV1-WAWIDE ANGLE REFLECTOR
Ø7/8" ELECTRICALKNOCK OUTBOTH ENDS
Ø7/8" ELECTRICALKNOCK OUT
222 T5HO 2L 4 UNV1LIGHT FIXTURE
(T5HO: 46" )(T8/T8HO/T12: 48")
TOOL LESSACCESS FASTENER
8 Ft. fixture options and dimensions - See Page 87
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
7
Fabricated from pre-painted cold rolled steel, the 229H Series is ideal for a variety of industrial lighting needs. A unique hinged ballast cover provides easy access to internal wiring and ballast for installation or service without the need to remove lamps. The 229H uses a 5 Ft. 3-wire whip which reduces installation time by not having to open the fixture. Available in T8, T8HO, or T5HO lamps. Lamps not included.
LISTINGS: UL 1598 listed U.S. and Canada
FEATURES: Heavy duty open industrial fixture. Hinged ballast plate allows for the fixture to be lamped prior to installation. Sturdy 20 gauge steel with durable pre-painted white enamel finish.
ELECTRICAL: Utilizes 32, 44, and 54 watt 4 Ft. lamps. Available in universal, 120, 277 and 347 volt electronic ballasts. (Other voltages available, consult factory)
OPTIONS: ALL OPTIONS ORDERED SEPARATELy A: Pattern 12 acrylic diffuser available in 32W T8 only. WG: Zinc plated wire guard (factory installed) PC: Post painted polyester white powder coat paint EM: Emergency battery backup ballast 120 or 277V - MUST SPECIFY 2 or 3 Lamp options. (lamps sold separately) • MOUNTING KITS - ordered separately - see next page Chain hanging kit - #3218
WG: Zinc plated wire guard option
Paint Booths (Outside behind glass panel)
General Industrial Task Lighting
229H SERIES229H SERIESG E N E R A L I N D U S T R I A L L I G H T I N G
GE
NE
RA
L I
ND
US
TR
IAL
LIG
HT
ING
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 20128
www.ldpi-inc.com
48 1/4” nominal
14 1/2”
Wire whip not shown
Ballast plate is hinged for easy access
4”
24” Chain piece (Qty. 2)
Chain hangerbracket (Qty. 2)
229H Light fixture
PN: 3218 Chain hang kit
MOUNTING - ORDERED SEPARATELy
LAMPS SOLD SEPARATELy(Multiple voltages available, consult factory)*Normally stocked fixture (Consult factory for lead time on non-stock products.)
CAN SHIP VIA UPS
4L: 4 lamp3L: 3 lamp2L: 2 lamp WG: Zinc plated wire guard**
A: Pattern 12 acrylic diffuser***EM: Emergency battery back up ballastPC: Powder coat paint - white
**Must be installed at the factory***Diffuser is only available in 32W T8
120-277: 120-277 Volt (T5HO & T8 ONLy)120: 120 Volt277: 277 Volt347-480: 347-480 Volt (T5HO ONLy)
T5HO: 54WT8: 32W*T8HO: 44W
SERIES LAMP TyPE LAMP QTy VOLTAGE OPTIONS
229H SERIES229H SERIESG E N E R A L I N D U S T R I A L L I G H T I N G
DIMENSIONS (Nominal)
229H
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
9
The 236 Series is a well designed fixture for Open Industrial High Bay applications. This fixture features a white pre-painted steel housing with a white powder coat finish option, and sports either a white or specular reflector system for the perfect lighting distribution for your application. The fixture is available in a 2, 4, 6 or 8 lamp configuration, using T8 or T5HO lamps. Lamps not included.
LISTINGS: UL 1598 listed U.S. and Canada
FEATURES: Rigid one piece 20 gauge steel with pre-painted white enamel finish. Twist lock lamp holders High lumen to watt ratio Higher mortality curve than HID for higher levels of illumination over time.
ELECTRICAL: Available in 32 and 54 watts with T8 and T5HO lamps Voltages of 120-277 and 347-480
HOUSING: Rigid one piece formed housing constructed of 20 gauge Pre-paint steel. Sturdy 20 gauge durable white enamel finished steel Specular Reflector with 91% Reflectivity
OPTIONS: ALL OPTIONS ORDERED SEPARATELy Cable mount kit Cord & plug Specular reflector Wire guard Occupancy sensor Powder coat fixture Acrylic lens
WarehousesGymnasiums
Ice RinksManufacturing Facilities
Big-Box Retailers
236 SERIES236 SERIESH I G H B AY L I G H T I N G
HIG
H B
AY
LIG
HT
ING
WHITE REFLECTOR SPECULAR REFLECTOR
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201210
www.ldpi-inc.com
DIMENSIONS (Nominal)
T8: 32WT8HLO: 32WT5HO: 54W
2L: 2 Lamp4L: 4 Lamp6L: 6 Lamp8L: 8 Lamp
4: 50” (nominal) UNV1: 120-277 Volts 50/60Hz120: 120 Volts 60Hz277: 277 Volts 60HzUNV2: 347/480 Volts 50/60 Hz - T5HO ONLY
CA5: Cable Mount 60” NominalCP6: 120: 6’ Cord, L5-15PCP6: 277: 6’ Cord, L7-15PHB: Specular ReflectorWG: Wire Guard (for complete kit see chart*)OC: Occupancy Sensor (used with a program start ballast)PC: Powder CoatA: Acrylic Lens (for complete kit see chart**)
OPTIONSLAMP TyPE LAMP QTy LENGTH (Ft.) VOLTAGE
236 SERIES236 SERIESH I G H B AY L I G H T I N G
2L = 8 1/2”4L = 15 3/4”6L = 23”8L = 30 1/4”
3 5/8”
T8 and T8HO = 48 1/4”T5HO = 46 1/4”
60 MAX
5 1/2”
2L = 9 1/8”4L = 16 3/8”6L = 23 5/8”8L = 30 7/8”
4 3/16”
Y-FIT Toggled endFixing gripple60” nominal
OccupancySensor
Wire GuardZinc plated
6 Lamp shown
6 Ft. cord
120V Plug (L5-15P) or277V Plug (L7-15P)
46 1/8”
MODEL WIRE GUARD KIT* ACRyLIC LENS KIT**236-T5HO-2L 8182 8180236-T8-2L 8183 8181236-T5HO-4L 8178 8176236-T8-4L 8179 8177236-T5HO-6L 7238 8090236-T8-6L 7060 8138236-T5HO-8L 8186 8184236-T8-8L 8187 8185
SERIES
236
LAMPS SOLD SEPARATELy
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
11
The 240 Series is a very versatile fixture that is UL listed for hazardous environments (Class I Division 2 Groups A, B, C and D, Class II Division 2 Groups F and G, and Class III). It is an ideal fixture for industrial applications, wet locations and task lighting. Optional adjustable mounting brackets allow for precise aiming in multiple angles suitable for most applications. The 240 Series is available in 2, 3, 4, 5 and 6 lamp options, all using a 3/16” tempered glass lens with acrylic and polycarbonate optional lenses. With multiple hub locations, the 240 Series can meet most of your wiring needs. Lamps not included.
LISTINGS: UL 844 listed U.S. and Canada UL 1598 listed U.S. and Canada Class I Division 2 Groups A,B,C,D Class II Division 2 Groups F,G Class III Listed for wet locations IP65 40 C ambient rating 55 C ambient rating for T8 (32 watt fixtures only)
FEATURES: Front access fixture for hazardous locations Hinged front door frame Hinged ballast tray Sturdy 18 Ga. steel white powder coated housing Spring loaded lamp holders - standard 3/16” tempered glass lens Zinc latches
ELECTRICAL: Available in 28, 32, 44 and 54 watts with T5, T5HO, T8, and T8HO lamps. Voltages of 120, 277, 347 & 480 Through feed wiring
OPTIONS: ALL OPTIONS ORDERED SEPARATELy Adjustable surface mount brackets Cable mount Chain mount kit 8’ wire whip Specular reflector Wire guard Fusing (not listed for Canada) Acrylic lens Polycarbonate lens EM: Emergency battery backup ballast HLO (high light output) ballast for T8 32 watt lamp only
• MOUNTING KITS - ordered separately - see page 89
Chemical PlantsPaper Mills
TunnelsWater TreatmentSeacoast Areas
Prep, Inspection, SandingMachining Areas
Coal & Dust Storage
240 SERIES240 SERIESVA P O R / D U S T P R O O F L I G H T I N G
VA
PO
R/D
US
T P
RO
OF
LIG
HT
ING
EM optioned fixture
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201212
www.ldpi-inc.com
DIMENSIONS (Nominal)
T5: 28WT5HO: 54WT8: 32WT8HO: 44W*
2L3L4L5L6L
120: 120 Volts277: 277 Volts 347: 347 VoltsUNV1: 120-277 Volts††
UNV2: 347-480 Volts***
TS: Top & Side Hubs**AM: Adjustable Angle Mounting Brackets (PN: 6856)†
6856SS: AM Stainless Steel†CB: Cable Mount (PN: 6875) Includes 5 ft. cables std.6875SS: CB Stainless Steel. Includes 5 ft. cables std. (Consult Factory for availability)WH: 8’ 3-Wire WhipSR: Specular High Bay ReflectorW: Wire GuardF: FuseA: Acrylic LensP: Polycarbonate Lens7979: Chain mount kitEM: Emergency battery backup ballast††
(Ambient reduced to 40°C)8HLO: High light output ballast for T8 32W lamp only 10357: Vertical Mounting Bracket
OPTIONSLAMP TyPE LAMP QTy VOLTAGE
LAMPS SOLD SEPARATELy* 120 or 277 volt must be specified on T8HO** 1/2” NPT standard*** UNV2 T5HO Only† For horizontal or ceiling mounted fixture only†† EM available as UNV1 (120-277) only
HUBSERIES240
240 SERIES240 SERIESVA P O R / D U S T P R O O F L I G H T I N G
53 1/8"
"A"
"A":2 LAMP: 12 3/16"3 & 4 LAMP: 16 3/16"5 & 6 LAMP: 20 11/16"
INTEGRATED ACCESSDOOR HINGE
1/2 NPT BOTH ENDS1/2 NPT HUBS
5 5/16”
51 1/2"
ROTARY DRAW LATCHES
BRACKETS FOROPTIONAL
MOUNTING KITSHINGED REFLECTOR
HINGED DOOR FRAME
T-Ratings Model Rated Ambient Deg. C
Supply Wiring Temp
Class I, Div. 2Operating
Temperature Code
Class II, Div. 2Operating
Temperature Code
Class IIIOperating
Temperature Code240-T5 40 75 T3C (160 C) T4A (120 C) T4A (120 C)240-T5HO 40 75 T3C (160 C) T4A (120 C) T4A (120 C)240-T8HO 40 75 T4A (120 C) T4A (120 C) T4A (120 C)240-T8* 55 75 T5 (100 C) T4A (120 C) T4A (120 C)
* 240 with EM option ambient is reduced to 40 C
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
13
The 240 8 Ft. Series is a very versatile fixture that is ETL listed for ordinary locations. It is an ideal fixture for industrial applications, wet locations and task lighting.Optional adjustable mounting brackets allow for precise aiming in multiple angles suitable for most applications.The 240 8 Ft. Series is available in 2, 3, 4, 5, 6, 8, 10 and 12 lamp options, all using a 3/16” tempered glass lens with acrylic and polycarbonate optional lenses. With multiple hub locations, the 240 8 Ft. Series can meet most of your wiring needs. Lamps not included.
General IndustrialTunnels
Water TreatmentSeacoast Areas
Prep, Inspection, SandingMachining Areas
240 8 Ft. SERIES240 8 Ft. SERIESVA P O R / D U S T P R O O F L I G H T I N G
VA
PO
R/D
US
T P
RO
OF
LIG
HT
ING
LISTINGS: ETL listed U.S. and Canada Listed for ordinary and wet locations 25 C ambient rating Conforms to UL 1598
FEATURES: Front access fixture for hazardous locations Hinged front door frame Hinged ballast tray Sturdy 18 Ga. steel white powder coated housing Spring loaded lamp holders - standard 3/16” tempered glass lens Zinc latches
ELECTRICAL: Available in: T5 28W, T5HO 54W, T8 32W & 59W, T8HO 44W & 86W Voltages of 120, 277, 347 & 480 Through feed wiring
OPTIONS: ALL OPTIONS ORDERED SEPARATELy Adjustable surface mount brackets Cable mount Chain mount kit 8’ wire whip Specular reflector Wire guard Fusing (not listed for Canada) Acrylic lens Polycarbonate lens EM: Emergency battery backup ballast HLO (high light output) ballast for T8 32 watt lamp only
• MOUNTING KITS - ordered separately - see page 90
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201214
www.ldpi-inc.com
DIMENSIONS (Nominal)
T5: (4') 28WT5HO: (4') 54WT8: (4') 32W, (8') 59WT8HO*: (4') 44W, (8') 86W
2L3L4L5L6L8L**10L**12L**
120: 120 Volts277: 277 Volts 347: 347 VoltsUNV1: 120-277 VoltsUNV2: 347-480 Volts***
TS: Top & Side Hubs†AM: Adjustable Angle Mounting Brackets (PN: 9349)♦
9349SS: AM Stainless Steel♦CB: Cable Mount (PN: 6875) Includes 5 ft. cables std.6875SS: CB Stainless Steel. Includes 5 ft. cables std. (Consult Factory for availability)WH: 8’ Wire WhipSR: Specular High Bay ReflectorW: Wire GuardF: FuseA: Acrylic LensP: Polycarbonate Lens9350: Chain mount kitEM: Emergency battery backup ballast8HLO: High light output ballast for T8 32W lamp only
OPTIONSLAMP TyPE LAMP QTy VOLTAGE
LAMPS SOLD SEPARATELy* 120 or 277 volt must be specified on T8HO** 4' lamps only*** UNV2 T5HO Only† 1/2” NPT standard♦ For horizontal or ceiling mounted fixture only
HUBSERIES240
240 8 Ft. SERIES240 8 Ft. SERIESVA P O R / D U S T P R O O F L I G H T I N G
"A"2 LAMP: 12 3/16"3 & 4 LAMP: 16 3/16"5 & 6 LAMP: 20 11/16"
"A"
101 3/8”
103”
INTEGRATED ACCESS DOOR HINGE
1/2 NPT HUBS 1/2 NPT HUBS
5 1/8”
BRACKETS FOROPTIONALMOUNTING KITS
HINGEDREFLECTOR
ROTORY DRAWLATCHES
HINGEDDOORFRAME
8: 8 Ft.
LENGTH8
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
15
The 241 Series is an ideal product for a multitude of areas including Paint Spray Booths, Prep Areas, Inspection Areas, Sanding or Machining Areas, even where Grain or Coal Dust may be a concern. This 4 lamp 4’ fixture is available in wattages including 32, 44, 54, and 60 watts with a rear access piano hinged door for easy access to lamps and ballast. The 241 Series carries multiple listings from UL and ETL for Class I Div. 2 & Class II Div. 2 applications. Must be mounted hinge side up. Lamps not included.
LISTINGS: ETL certified U.S. and Canada Class I Division 2 Groups A,B,C,D T3C (160 degree C) operating code Class II Division 2 Groups F,G T3C (160 degree C) operating code Listed for damp locations Listed for locations having deposits of readily combustible paint residues. UL 844 listed for hazardous locations Class I Division 2 Groups A,B,C,D T3C (160 degree C) operating code Conforms to UL 1598 and UL 844 Certified to CSA 22.2 No. 137 and 250
FEATURES: Piano hinged rear access fixture. Spring loaded lamp holders - Except T5HO
ELECTRICAL: Available in 32, 44, 54, and 60 watts in T5HO, T8, & T8HO lamps. Voltages of 120, 277, & 347 volts.
OPTIONS: ALL OPTIONS ORDERED SEPARATELy EM: Emergency battery backup ballast 120 or 277V MUST SPECIFY 5901: 8 Ft. 3-wire whip
• MOUNTING KITS - ordered separately - see page 91 4692: Installation kit
Paint Spray BoothsPrep Areas
Inspection AreasSanding AreasLaboratories
VA
PO
R/D
US
T P
RO
OF
LIG
HT
ING
241 SERIES241 SERIESVA P O R / D U S T P R O O F L I G H T I N G
Piano hinged rear access
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201216
www.ldpi-inc.com
DIMENSIONS (Nominal)
52 1/2”14
1/2”
5-1/8”
53 1/8”
15 1/
8”
Series Watts Lamp Qty Hub Order # Voltage
390241 Rear Access Only 32W T8 4 1/2” NPT 390241 3546 120-277 Volts 50/60HZ 1/2” NPT 390241347 3125 347 Volts 60HZ
32W T8HLO 4 1/2” NPT 390241 6974 120-277 Volts 60HZ
44W T8HO 4 1/2” NPT 390241120 4157 120 Volts 60HZ 1/2” NPT 390241277 3792 277 Volts 60HZ
54W T5HO 4 1/2” NPT 390241 4843 120-277 Volts 50/60HZ
LAMPS SOLD SEPARATELy(Multiple voltages available, consult factory)Mounting Options - See Page 91
241 SERIES241 SERIESVA P O R / D U S T P R O O F L I G H T I N G
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
17
The 260/261 Series is a product designed specifically for Paint Spray Booths. With a wider fixture design these products will provide increased photometric output and efficiencies. These 4 lamp 4’ fixtures are available in 32 Watts. The 260 Series allows for both Front and Rear access using a paint spray cutoff switch when the front door frame is opened. The 261 Series is a rear access only fixture and does not require paint spray cutoff. Both units carry multiple listings from ETL for Class I Div. 2 & Class II Div. 2 applications. Must be mounted hinge side up. Lamps not included.
LISTINGS: ETL listed for U.S. and Canada Class I Division 2 Groups A,B,C,D T3C (160 degree C) operating code Class II Division 2 Groups F,G T3C (160 degree C) operating code Listed for locations having deposits of readily combustible paint residues. Conforms to UL 1598 and UL 844 Certified to CSA 22.2 No. 137 and 250 FEATURES: 20 Gauge steel construction with white baked enamel finish which creates a durable, highly reflective finish. Housing styles for either front or rear accessibility in the Series 260, or rear access only in the Series 261.
LENS: 3/16” clear tempered glass.
ELECTRICAL: Paint spray cutoff switch for the front door frame access of the 260 Series. Available in 32 watts withT8 lamps. Voltages of 120, 277 & 347 volts.
OPTIONS: ALL OPTIONS ORDERED SEPARATELy EM: Emergency battery backup ballast 120 or 277V - MUST SPECIFY Wire whip 8 Ft. - 5901: 3-wire (261) or 5902: 5-wire (260)
• MOUNTING KITS - ordered separately - see page 92 Panel stiffener kit #1704 (fits 18 gauge panels only)
NOTE: Normally open magnetic switches are intended to be used to trigger a relay (furnished by others) which disables the paint system. Because of the small capacity of the switch a solid state relay is recommended. It may be desired by others to utilize a separate power supply to segregate the relay (furnished by others) from the lighting power supply. The magnetic switch IS NOT designed to directly control light operation! The magnetic switch is rated for 10 watts resistive at a maximum of 300 VAC.
CAUTION: Overloading the switch circuits WILL cause failure. LDPI, Inc. recommends having a certified electrician/engineer review loads to ensure that overloading of switch does not occur.
Model 261: Rear access only
Interlock MicroswitchModel 260
Paint Spray BoothsClean Rooms
(Class 100 - 100,000)Locker Rooms
Computer AreasDamp Locations
Fuel Storage
260/261 SERIES260/261 SERIESVA P O R / D U S T P R O O F L I G H T I N G
VA
PO
R/D
US
T P
RO
OF
LIG
HT
ING
Model 260: Front and rear access
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201218
www.ldpi-inc.com
DIMENSIONS (Fixture dimensions are nominal. Cut-out dimensions are actual.)
49 13/16”
53 1/4”
18 3/
8”
21 3/
4”
5 3/4”
Rear Access PanelModels 260 & 261
Series Watts Lamp Qty Hub Order # Voltage
390260 32W T8 4 1/2” NPT 390260 3546 120-277 Volts 50/60HZFront & Rear Access 4 1/2” NPT 390260347 3125 347 Volts 60HZ
32W T8HLO 4 1/2” NPT 390260 6974 120-277 Volts 60HZ
390261 32W T8 4 1/2” NPT 390261 3546 120-277 Volts 50/60HZRear Access Only 4 1/2” NPT 390261347 3125 347 Volts 60HZ
32W T8HLO 4 1/2” NPT 390261 6974 120-277 Volts 60HZ
LAMPS SOLD SEPARATELy(All Options Ordered Separately)Mounting Options - See Page 92
51 1/4”7 5/8” 7 5/8”12” 12” 12”
12”19 5/8”
3 13/16”
3 13/16”
3/8” TYP.
HOLE DETAILCUT LIGHT HOLE
19 5/8” X 51 1/4”
5/16” Dia. 12 Holes
260/261 SERIES260/261 SERIESVA P O R / D U S T P R O O F L I G H T I N G
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
19
The 280/281 Series is a product designed specifically for Paint Spray Booths. With a wider fixture design these products will provide increased photometric output and efficiencies. These 4 lamp 8’ fixtures are available in wattages including 59 and 86 watts.The 280 Series allows for both Front and Rear access using a paint spray cutoff switch when either front door frame is opened. The 281 Series is a rear access only fixture and does not require paint spray cutoff. Both units carry multiple listings from ETL for Class I Div. 2 & Class II Div. 2 applications. Must be mounted hinge side up. Lamps not included.
LISTINGS: ETL listed for U.S. and Canada Class I Division 2 Groups A,B,C,D T3C (160 degree C) operating code Class II Division 2 Groups F,G T3C (160 degree C) operating code Listed for locations having deposits of readily combustible paint residues. Conforms to UL 1598 and UL 844 Certified to CSA 22.2 No. 137 and 250
FEATURES: 20 Gauge steel construction with white baked enamel finish which creates a durable, highly reflective finish. Housing styles for either front or rear accessibility in the Series 280, or rear access only in the Series 281.
LENS: 3/16” clear tempered glass.
ELECTRICAL: Paint spray cutoff switch for each front door frame access of the Series 280. Available in 59 or 86 watts in T8 or T8HO lamps. Voltages of 120, & 277 volts.
OPTIONS: ALL OPTIONS ORDERED SEPARATELy EM: Emergency battery backup ballast 120 or 277V - MUST SPECIFY Wire whip 8 Ft. - 5901: 3-wire (281) or 5902: 5-wire (280)
• MOUNTING KITS - ordered separately - see page 93 Panel stiffener kit #1728 (fits 18 gauge panels)
NOTE: Normally open magnetic switches are intended to be used to trigger a relay (furnished by others) which disables the paint system. Because of the small capacity of the switch, a solid state relay is recommended. It may be desired by others to utilize a separate power supply to segregate the relay (furnished by others) from the lighting power supply. The magnetic switch IS NOT designed to directly control light operation! The magnetic switch is rated for 10 watts resistive at a maximum of 300 VAC.
CAUTION: Overloading the switch circuits WILL cause failure. LDPI, Inc. recommends having a certified electrician/engineer review loads to ensure that overloading of switch does not occur.
Model 281: Rear access only
Paint Spray BoothsClean Rooms
(Class 100 - 100,000)Locker Rooms
Computer AreasDamp Locations
Fuel Storage
280/281 SERIES280/281 SERIESVA P O R / D U S T P R O O F L I G H T I N G
VA
PO
R/D
US
T P
RO
OF
LIG
HT
ING
Model 280: Front and rear access
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201220
www.ldpi-inc.com
DIMENSIONS (Fixture dimensions are nominal. Cut-out dimensions are actual.)
Series Watts Lamp Qty Hub Order # Voltage
390280 59W T8 4 1/2” NPT 390280 3281 120-277 Volts 60HZFront & Rear Access 86W T8HO 4 1/2” NPT 390280 4854 120-277 Volts 50/60HZ
390281 59W T8 4 1/2” NPT 390281 3281 120-277 Volts 60HZRear Access 86W T8HO 4 1/2” NPT 390281 4854 120-277 Volts 50/60HZ
LAMPS SOLD SEPARATELy(All Options Ordered Separately)Mounting Options - See Page 93
100 5/8”13 3/8” 12” 12” 12”
3 13/16”
3 13/16”
3/8” TYP.
280/281 FIXTURE HOLE DETAIL
5/16” Dia. 12 Holes
7 5/8”7 5/8”
12”
19 5/
8”
12” 12” 12”
280/281 SERIES280/281 SERIESVA P O R / D U S T P R O O F L I G H T I N G
18 3/8"
21 5/8”
99 5/16"
102 11/16"
5 3/4" 5 1/4"
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
21
The Slim Light Series features a 20 Ga. baked white enamel steel housing that is only 2 1/4” thick maximizing the available space allowed for your paint spray booth. The Slim Light Series is available in lengths of 3 & 4’ with 2, 4 or 6 lamp options. The 3’ fixtures are available in T8 25 watts. The 4’ fixtures are available in 32 and 54 watts T5HO, T8 or T8HLO. This series provides front door frame access with a paint spray cutoff switch when opened. ETL listed in the U.S. and Canada, the Slim Light Series has multiple listings for inside access. Must be mounted hinge side up when wall mounted. Lamps not included.
LISTINGS: ETL listed for U.S. and Canada Class I Division 2 Groups A,B,C,D T3C (160 degree C) operating code Class II Division 2 Groups F,G T3C (160 degree C) operating code (The Slim Light 420 & 440 in T8 are UL listed for Class I Division 2 Groups A, B, C, & D.) Listed for locations having deposits of readily combustible paint residues. UL 844 listed for Hazardous Locations Meets UL 1598 standards for wet/damp locations Conforms to UL 1598 and UL 844 Certified to CSA 22.2 No. 137 and 250
FEATURES: 20 Gauge steel construction with white baked enamel finish which creates a durable, highly reflective finish. The housing is a front access for convenient access, and the 2 1/4” depth minimizes the space needed in the paint spray booth for the fixture. LENS: 3/16” clear tempered glass.
ELECTRICAL: Paint spray cutoff switch in the front door frame. Available in: 3 Ft. 25 watt T8. 4 Ft. 32 and 54 watt T8, T8HLO or T5HO Voltages of 120, 277, 347 & 480 volts.
OPTIONS: ALL OPTIONS ORDERED SEPARATELy EM: Emergency battery backup ballast (excludes 390360 fixtures) 120 or 277V MUST SPECIFY (T5HO EM fixture is 3 1/2" deep) 5902: 8 Ft. 5-wire whip HSR: High performance specular reflector (only available on 390440 T8 and T8HLO) HWR: High performance white reflector (only available on 390440 T8 and T8HLO) Corner/hip mount #4714 - see page 94 (available for the 390440J-3546 fixture ONLY) Lens and fixture preservation: lens film and blast booth lens cover - see page 125
NOTE: Normally open magnetic switches are intended to be used to trigger a relay (furnished by others) which disables the paint system. Because of the small capacity of the switch a solid state relay is recommended. It may be desired by others to utilize a separate power supply to segregate the relay (furnished by others) from the lighting power supply. The magnetic switch IS NOT designed to directly control light operation! The magnetic switch is rated for 10 watts resistive at a maximum of 300 VAC.
CAUTION: Overloading the switch circuits WILL cause failure. LDPI, Inc. recommends having a certified electrician/engineer review loads to ensure that overloading of switch does not occur.
Paint Spray BoothsClean Rooms
(Class 100 - 100,000)Locker Rooms
Computer AreasDamp Locations
Fuel StorageControl Rooms for
Drilling Rigs
PA
INT
BO
OT
H L
IGH
TIN
G
SLIM LIGHT SERIESSLIM LIGHT SERIESPA I N T B O O T H L I G H T I N G
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201222
www.ldpi-inc.com
DIMENSIONS (Fixture dimensions are nominal. Cut-out dimensions are actual.)
TyPE MODEL A B C D3 FT. 2 LAMP 390320 9 1/2” 13” 38” 39-7/8”3 FT. 4 LAMP 390340 14 1/2” 18” 38” 39-7/8”3 FT. 6 LAMP 390360 19 1/2” 23” 38” 39-7/8” 4 FT. 2 LAMP 390420 9 1/2” 13” 50” 51-7/8”4 FT. 4 LAMP 390440 14 1/2” 18” 50” 51-7/8”4 FT. 6 LAMP 390460 19 1/2” 23” 50” 51-7/8”
NOTE: LIGHT FIXTURE’S GLASS FRAME EXTENDS 3/8” INTO BOOTH WHEN MOUNTED IN BOOTH PANEL.
Mounting - See Page 95
38 1/4”
16” 16”
HOLE DETAIL (3 FT. FIXTURES)
3 1/8”
E5/16” TYP
38 7/8”
1/2” TYP
1 7/8”
1 7/8”
5/16” DIA. 10 Holes F
3 FOO
T SL
IM LI
GHT
50 1/4”
16” 16”
HOLE DETAIL (4 FT. FIXTURES)
1 1/8”
E5/16” TYP
50 7/8”
1/2” TYP
1 7/8”
1 7/8”
5/16” DIA. 12 Holes F
16”
4 FOO
T SL
IM LI
GHT
TYPE E F2 LAMP 10 3/4” 7”4 LAMP 15 3/4” 12”6 LAMP 20 3/4” 17”
Series Watts Lamp Qty Hub Order # Voltage
390320 (2 lamp) 25W T8 2 1/2” NPT 390320 3613* 120-277 Volts 50/60 Hz 2 1/2” NPT 390320347 3276 347 Volts 60 Hz
390340 (4 lamp) 25W T8 4 1/2” NPT 390340 3546* 120-277 Volts 50/60 Hz 4 1/2” NPT 390340347 3125 347 Volts 60 Hz
390360 (6 lamp) 25W T8 6 1/2” NPT 390360 3546 120-277 Volts 50/60 Hz 6 1/2” NPT 390360347 3125 347 Volts 60 Hz
390420 (2 lamp) 32W T8 2 1/2” NPT 390420 3613* 120-277 Volts 50/60 Hz 2 1/2” NPT 390420347 3276 347 Volts 60 Hz
32W T8HLO 2 1/2” NPT 390420 6975 120-277 Volts 50/60 Hz 54W T5HO 2 1/2” NPT 390420 3265 120-277 Volts 50/60 Hz 2 1/2” NPT 390420 5420 347-480 Volts 50/60 Hz
390440 (4 lamp) 32W T8 4 1/2” NPT 390440 3546* 120-277 Volts 50/60 Hz 4 1/2” NPT 390440347 3125 347 Volts 60 Hz 32W T8HLO 4 1/2” NPT 390440 6974 120-277 Volts 50/60 Hz 54W T5HO 4 1/2” NPT 390440 4843* 120-277 Volts 50/60 Hz 4 1/2” NPT 390440 5421 347-480 Volts 50/60 Hz 390460 (6 lamp) 32W T8 6 1/2” NPT 390460 3546* 120-277 Volts 50/60 Hz 6 1/2” NPT 390460347 3125 347 Volts 60 Hz 32W T8HLO 6 1/2” NPT 390460 7059 120-277 Volts 50/60 Hz 54W T5HO 6 1/2” NPT 390460 3265* 120-277 Volts 50/60 Hz 6 1/2” NPT 390460 5420 347-480 Volts 50/60 Hz
LAMPS SOLD SEPARATELy
All options ordered separately
*Normally stocked fixture. Consultfactory for lead
times on non-stockproducts.
3 FOO
T SL
IM LI
GHT
4 FOO
T SL
IM LI
GHT
CAN SHIP VIA UPS 2 & 4 Lamp ONLy
Additional packaging required.
SLIM LIGHT SERIESSLIM LIGHT SERIESPA I N T B O O T H L I G H T I N G
C D
AB
2 1/4”**1/2 NPTCONDUIT HUBT5HO ONLy
*
*
* HUB LOCATIONS
** (T5HO EM fixture is 3 1/2" deep)
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
23
The 400 Series Rear Access product is an ideal paint spray booth product when a rear access fixture is desired. The 400 Series is also a vapor proof product with an ETL listing of Class I Division 2 rating. This series now has a 2’ fixture as well as the 4’ fixture cataloged. The 4’ fixture comes in 2, 4 & 6 lamp with the following lamp options: T8 32W, T8HO 44W, & T5HO 54W lamps. The 2’ - 3 lamp fixture uses (3) T8 17W lamps. Lamps not included.
LISTINGS: ETL listed for U.S. and Canada Class I Division 2 Groups A,B,C,D T3C (160 degree C) operating code Class II Division 2 Groups F,G T3C (160 degree C) operating code Listed for locations having deposits of readily combustible paint residues. UL Class I Division 2 Groups A,B,C,D for the 421 & 441 series T8 32W only. Meets UL 844 standards for hazardous locations Meets UL 1598 Standards for wet/damp locations Meets NFPA 33 standards for spray applications using flammable or combustible materials. Conforms to UL 1598 and UL 844 Certified to CSA 22.2 No. 137 and 250
FEATURES: Piano hinged rear access fixture - easy relamping. Telescopic/spring loaded lamp holders 20 gauge (enclosed & gasketed) steel construction with white baked enamel finish which creates a durable, highly reflective finish.
LENS: 3/16” clear tempered glass.
ELECTRICAL: Available in 2 Ft. 17 watt T8 lamps and 4 Ft. 32, 44 and 54 watts, T8, T8HO and T5HO lamps. Voltages of 120, 277, 347 and 480.
OPTIONS: ALL OPTIONS ORDERED SEPARATELy 5901: 8 Ft. 3-wire whip Lens and fixture preservation: lens film and blast booth lens cover - see page 125
PA
INT
BO
OT
H L
IGH
TIN
G
400 SERIES400 SERIESPA I N T B O O T H L I G H T I N G
Paint Spray BoothsClean Rooms
(Class 100 - 100,000)Locker Rooms
Computer AreasDamp Locations
Fuel Storage
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201224
www.ldpi-inc.com
DIMENSIONS (Fixture dimensions are nominal. Cut-out dimensions are actual.)
CD
A B
3 1/2”
MODEL A B C D E F390231 10 1/2” 12 1/2” 26” 28 3/8” 11 3/4” 8” 390421 10 1/2” 12 1/2” 50 1/4” 52 3/8” 10 3/4” 7” 390441 15 1/2” 17 1/2” 50 1/4” 52 3/8” 15 3/4” 12” 390461 20 1/2” 22 1/2” 50 1/4” 52 3/8” 20 3/4” 17”
FIXTUREDIMENSIONS
MOUNTINGDIMENSIONS
Series Watts Lamp Qty Hub Order # Voltage
390231 (2 ft. 3 lamp) 17W T8 3 1/2” NPT 390231 3546 120-277 Volts 50/60 Hz
390421 (4 ft. 2 lamp) 32W T8 2 1/2” NPT 390421 3613 120-277 Volts 50/60 Hz 2 1/2” NPT 390421347 3276 347 Volts 60 Hz
32W T8HLO 2 1/2” NPT 390421 6975 120-277 Volts 50/60 Hz 44W T8HO 2 1/2” NPT 390421120HO 4156 120 Volts 60 Hz 2 1/2” NPT 390421277HO 3794 277 Volts 60 Hz
54W T5HO 2 1/2” NPT 390421 3265 120-277 Volts 50/60 Hz 2 1/2” NPT 390421 5420 347-480 Volts 50/60 Hz
390441 (4 ft. 4 lamp) 32W T8 4 1/2” NPT 390441 3546 120-277 Volts 50/60 Hz 4 1/2” NPT 390441347 3125 347 Volts 60 Hz
32W T8HLO 4 1/2” NPT 390441 6974 120-277 Volts 50/60 Hz
44W T8HO 4 1/2” NPT 390441120HO 4157 120 Volts 60 Hz 4 1/2” NPT 390441277HO 3792 277 Volts 60 Hz
54W T5HO 4 1/2” NPT 390441 4843 120-277 Volts 50/60 Hz 4 1/2” NPT 390441 5421 347-480 Volts 50/60 Hz
390461 (4 ft. 6 lamp) 32W T8 6 1/2” NPT 390461 3546 120-277 Volts 50/60 Hz 6 1/2” NPT 390461347 3125 347 Volts 60 Hz
32W T8HLO 6 1/2” NPT 390461 7059 120-277 Volts 50/60 Hz
44W T8HO 6 1/2” NPT 390461120HO 4157 120 Volts 60 Hz 6 1/2” NPT 390461277HO 3792 277 Volts 60 Hz
54W T5HO 6 1/2” NPT 390461 3265 120-277 Volts 50/60 Hz 6 1/2” NPT 390461 5420 347-480 Volts 50/60 Hz
LAMPS SOLD SEPARATELy (Multiple voltages available, consult factory)
CAN SHIP VIA UPS2 & 4 Lamp ONLy
50 1/4”
16” 16”
HOLE DETAIL (4 FT. FIXTURES)
1 1/8”
E5/16” TYP
50 7/8”
1/2” TYP
1 7/8”
1 7/8”
Ø 5/16” DIA. 12 Holes
F
16”
Mounting - See Page 96
HOLE DETAIL (2 FT. 390231)
Ø 5/16” DIA. 10 Holes
E10 3/4”
F
26 1/4”
1 7/8”
1/2” TYP12”12”
26 7/8”1 7/16”
5/16”TyP
400 SERIES400 SERIESPA I N T B O O T H L I G H T I N G
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
25
The Series 440T / 440THO is a slim 2 1/4” product that is suited to being used in paint spray booths (with recessed flange mount option) & clean room applications where a lay-in troffer application is desired. The Series 440T / 440THO is a vapor & dust proof product with ETL listings of Class I Division 2 & Class II Division 2. This series comes in 4 lamp configurations of either T5 28W or T5HO 54W lamp options. Both utilize a specular insert for increased light output. Lamps not included.
LISTINGS: ETL listed for U.S. and Canada Class I Division 2 Groups A,B,C,D T3C (160 degree C) operating code Class II Division 2 Groups F & G T3C (160 degree C) operating code Listed for locations having deposits of readily combustible paint residues. Conforms to UL 1598 and UL 844 Certified to CSA 22.2 No. 137 and 250 FEATURES: 20 Gauge enclosed, sealed & gasketed, post painted white powder coated finish. Front access troffer style: Lay-in fixture fits 2x4’ grids with up to a 2” industrial “T-grid” suspension system. Highly reflective white finish with a specular insert for increased light output. 90 degree self-contained hinge system (reduces overspray and dust)
LENS: 3/16” prismatic tempered glass lens.
ELECTRICAL: Available in 28 and 54 watts with T5 and T5HO lamps 120-277 and 347-480 volt universal ballast. Hub location varies, dependent on mounting style and customer preference. Paint spray cutoff switch for front door frame access.
OPTIONS: ALL OPTIONS ORDERED SEPARATELy 5902: 8 Ft. 5-wire whip 3/16" clear tempered glass 2 and 3 lamp configurations • MOUNTING KITS - ordered separately - see next page 3330: surface mount, 3331: recessed flange mount or 3332: box panel mount
NOTE: Normally open magnetic switches are intended to be used to trigger a relay (furnished by others) which disables the paint system. Because of the small capacity of the switch a solid state relay is recommended. It may be desired by others to utilize a separate power supply to segregate the relay (furnished by others) from the lighting power supply. The magnetic switch IS NOT designed to directly control light operation! The magnetic switch is rated for 10 watts resistive at a maximum of 300 VAC.
CAUTION: Overloading the switch circuits WILL cause failure. LDPI, Inc. recommends having a certified electrician/engineer review loads to ensure that overloading of switch does not occur.
440T/THO SERIES440T/THO SERIEST- 5 o r T 5 H O T R O F F E R
T-5
or
T5
HO
TR
OF
FE
R
Paint Spray BoothsClean Rooms
(Class 100 - 100,000)Locker Rooms
Computer AreasDamp Locations
Fuel StorageLimited plenum areas
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201226
www.ldpi-inc.com
DIMENSIONS (Nominal) & MOUNTING (ordered separately)
BOX PANEL MOUNTP/N 3332
4 1/4”
4 1/4”
15”23 1/2” 15
15
15
47 1/2”
2 1/4”
1 1/4”
SURFACE MOUNTKIT P/N 3330
2 1/4”
4 1/4”
4 1/4”
15”23 1/2”
47 1/2”
49 1/2”
51 1/2”
RECESSED FLANGE MOUNT: P/N 3331
15
15
15
2 1/4”
4 1/4”
4 1/4”
15”23 1/2”27 1/2”
47 1/2”
49 1/2”
51 1/2”
23 1/2”
47 1/2”
2 1/4”
LAy-IN MOUNTSTANDARD
Mounting MethodsCeiling Lay-In for 2x4’ Grid (standard) Surface Mount: Kit P/N 3330 Recessed Flange Mount: Kit P/N 3331 Box Panel Mount: Kit P/N 3332
A
B
C(Back of Fixture)
D
HUB LOCATIONS A, B and D NOT recommended for Lay-in Mount
C: not for use with surface mount.
T: T5 28WTHO: T5HO 54W
L: Lay-in*R: Recessed flange/box panel (for use with kits 3331 & 3332)S: Surface mount (for use with kit 3330) * Lay-in Mount is standard, Other mounting options ordered separately
Hub locationA, B, C or D See Hub Locations
4425: T5 120-277 Volts3265: T5HO 120-277 Volts5420: T5HO 347-480 Volts
MOUNT HUB BALLASTLAMP TyPE
LAMPS SOLD SEPARATELy
HOUSING
PP: PrePaintPC: Powder Coat (Standard)AS: Aluminized SteelGS: Galvanized Steel
440T/THO SERIES440T/THO SERIEST- 5 o r T 5 H O T R O F F E R
SERIES390440
Independent support bracket shown. Lay-in mount option only.
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
27
The 440 2x4 Series is a slim 4 1/4” product that is suited for use in clean room applications where a lay-in, recessed or surface mount troffer application is desired. The 440 2x4 Series is a Vapor & Dust proof product with ETL listings of Class I Division 2 & Class II Division 2. This series comes in a 4 lamp configuration of T8 32W lamps, and utilizes a specular polished reflector system for increased light output. Lamps not included.
LISTINGS: ETL listed for U.S. and Canada Class I Division 2 Groups A,B,C,D T3C (160 degree C) operating code Class II Division 2 Groups F & G T3C (160 degree C) operating code Conforms to UL 1598 and UL 844 Certified to CSA 22.2 No. 137 and 250
FEATURES: 20 Gauge enclosed, sealed & gasketed steel construction with post painted white powder coat finish. Front access troffer style: Lay-in fixture fits 2x4’ grids with up to a 2” industrial “T-grid” suspension system. Standard lay-in mounting
LENS: 3/16” prismatic tempered glass lens.
ELECTRICAL: Available in 32 watts with T8 lamps 120-277 volt universal ballast
OPTIONS: ALL OPTIONS ORDERED SEPARATELy EM: Emergency battery backup ballast 120 or 277V - MUST SPECIFY 5901: 8 Ft. 3-wire whip 3/16" clear tempered glass lens
440 2x4 SERIES440 2x4 SERIEST- 8 T R O F F E R
T-8
TR
OF
FE
R
Clean Rooms(Class 100 - 100,000)
Locker RoomsComputer AreasDamp Locations
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201228
www.ldpi-inc.com
47 3/4"
23 1/2"
3 15/16"
440 2x4 SERIES440 2x4 SERIEST- 8 T R O F F E R
DIMENSIONS (Nominal) & MOUNTING (Ordered Separately)
23 1/2"
47 3/4"
1 3/8"
15"
15"
15"
1 3/8"
15"
4 1/4"
4 1/4"
3 15/16"
1 1/8" TYP
BOX PANEL MOUNTP/N 3332
51 1/2"
3 15/16"
47 3/4"
23 1/2"
4 1/4"
15"
4 1/4"
49 1/2"
SURFACE MOUNTKIT P/N 8362
49 1/2"
3 1/4"
15"
15"
15"
2 1/4"
2 1/4"3 1/4"
4 1/4"5 1/4"
15"
4 1/4"5 1/4"
23 1/2"
51 1/2"
3 15/16"
47 3/4"
23 1/2"
25 1/2"
RECESSED FLANGE MOUNT: P/N 8363
LAy-IN MOUNTSTANDARD
Mounting MethodsCeiling Lay-In for 2’ X 4’ Grid (standard) Surface Mount: Kit P/N 8362 Recessed Flange Mount: Kit P/N 8363 Box Panel Mount: Kit P/N 3332
A
BC
(Back of Fixture)
D
HUB LOCATIONS A, B, C and D will clear for Lay-in Mount
T: T8 32W
L: Lay-in*R: Recessed flange/box panel (for use with kits 8363 & 3332)S: Surface mount (for use with kit 8362) * Lay-in Mount is standard, Other mounting options ordered separately
Hub locationA, B, C or D See Hub Locations
3546: T8 120-277 Volts 50/60 Hz
MOUNT HUB BALLASTLAMP TyPE
LAMPS SOLD SEPARATELy
HOUSING
PP: PrePaintPC: Powder Coat (Standard)AS: Aluminized SteelGS: Galvanized Steel
SERIES3904402X4
Independent support bracket shown. Lay-in mount option only.
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
29
Suitable for interior or exterior applications. A lightweight, vapor tight, nonmetallic fixture ideal for corrosive or wet/damp environments. The 376 fixture features a fiberglass housing with an acrylic or polycarbonate lens, a continuous gasket design, along with an optional aluminum reflector available upon request. The 376 is ideal for commercial industrial or institutional applications providing maximum light output where humidity, dust, or fumes are possible. The 376 is resilient against corrosion and weathering. Lamps not included.
LISTINGS: UL 1598 listed for wet/damp locations UL Listed marine: Inside drip proof NSF: Splash zone non-food preparation NEMA 4 High pressure tested at 1500 PSI For information on the IP code see page 130.
FEATURES: Fiberglass: 5VA UL rated Available lengths: 2’, 4’ and 8’ For chemical resistance information see page 131.
GASKETING: Poured in place polyurethane gasket and cam latches seal the enclosure from the most hostile environments. Provides continuous positive gasket contact.
DIFFUSER: PR: UV stabilized polycarbonate lens with lineal ribs. A: UV stabilized impact resistant acrylic lens with lineal ribs. (Meets UV requirements of UL 756C) AC: Acrylic optically clear lens (4’ 2 or 3 lamp and 8’ only) FA: Frosted acrylic lens (4’ 2 or 3 lamp and 8’ only) (Not NSF listed)
FINISH: Housing: White polished fiberglass. Gear tray: white enamel
MOUNTING: Economical mounting system can provide dramatic savings on the installation labor. Durable stainless steel mounting hardware. No drilling necessary for the housing for installation.
ELECTRICAL: Available in 14, 17, 24, 28, 32, 54, 59 and 86 watts with T5, T5HO, T8, and T8HO lamps Voltages of 120, 277 and 347 All electric components are UL and CSA approved. Full metal gear tray carries all electrical components and provides for a positive ground.
OPTIONS: ALL OPTIONS ORDERED SEPARATELy HB: 93% reflective specular reflector EM: Emergency battery backup ballast - not available with 2’ fixture 120 or 277V - MUST SPECIFY SL: Stainless steel latches WD: Wide distribution enhanced aluminum reflector
IP 65 - 2 Ft.IP 67 - 4 Ft. & 8 Ft.
Parking Garages, TunnelsLocker Rooms
Water Treatment PlantsKitchens, Showers
Paper MillsFood Processing
Marinas/Offshore FacilitiesBreweries and BottlingLivestock ContainmentHospitals and Schools
376 SERIES376 SERIESW E T / D A M P L O C AT I O N S
WE
T/D
AM
P L
OC
AT
ION
S
2 lamp fixture with wide distribution (WD) lens and the acrylic optically clear (AC) lens NOTE: AC lens is 3.5” deep.
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201230
www.ldpi-inc.com
MOUNTING
DIMENSIONS (nominal)
OPTIONAL MOUNTING45 Mounting bracket kit (8' fixture requires 2 kits) P/N: 5151 1 lamp housing *Kit includes (2) 45 brackets and (2) 5080 brackets P/N: 5102 2 or 3 lamp housing Kit includes: (2) 45 brackets (2) 5081 brackets
Chain hung mounting bracket bail kit(8' fixture requires 2 kits) P/N: 5192 (narrow housing) P/N: 5193 (standard housing) *Kit includes (2) S-hooks (2) 2’ lengths of chain (2) 5150 chain hang looms (2) 5080 brackets (narrow housing only) (2) 5081 brackets (standard housing only)
• Mounting brackets provide impressive benefits.• Offers a huge advantage over more traditional enclosures.• Durable, stainless steel mounting hardware.• No drilling necessary for the housing for installation.• Installation time is dramatically reduced, providing lower installation costs.
45 mounting option
3 9/32”
45
Mounting bracket for narrow and standard lamp housing.
AB
CD
Narrow 1 lamp
Standard 2+ lamps
B
CD
PART # A B C D
376-__-1L-4-UNV-__ 51.75” 4.25” 4.00” 4.56”376-__-1L-5-UNV-__ 63.50” 4.25” 4.00” 4.56”376-__-2L-2-UNV-__ 27.25” 4.25” 6.75” 7.33”376-__-3L-2-UNV-__ 27.25” 4.25” 6.75” 7.33”376-__-2L-4-UNV-__ 51.75” 4.25” 6.75” 7.33”376-__-3L-4-UNV-__ 51.75” 4.25” 6.75” 7.33”376-__-2L-8-UNV-__ 100” 4.25” 6.75” 7.33”376-__-4L-8-UNV-__ 100” 4.25” 6.75” 7.33”376-__-6L-8-UNV-__ 100” 4.25” 6.75” 7.33”
“B” measurement: with Poly Molded diffuser. Poly Ribbed diffuser will measure 0.12” shorter.“B” measurement with Acrylic Optically Clear lens is 5.75”.
376 Shipping DimensionsProduct Weight Volume L W H
376-1L-4 8# 1.09 Cu.. Ft. 59” L 8” W 4” H376-1L-5 10# 1.29 Cu.. Ft. 70” L 8” W 4” H376-2L-2 6# .66 Cu.. Ft. 36” L 8” W 4” H376-2L-4 12# 1.09 Cu.. Ft. 59” L 8” W 4” H376-2L-8 20# 2.47 Cu.. Ft. 107” L 8” W 5” H376-3L-2 6# .66 Cu.. Ft. 36” L 8” W 4” H376-3L-4 12# 1.09 Cu.. Ft. 59” L 8” W 4” H376-4L-8 21# 2.47 Cu.. Ft. 107” L 8” W 5” H376-6L-8 23# 2.47 Cu.. Ft. 107” L 8” W 5” H
* IP 65 for MAX (2) 32 W lamps 4 Ft. housing and (4) 32 W lamps 8 Ft. Housing. IP 55 for all models 2 Ft., 4 Ft., and 8 Ft IP 67 for all 4 Ft. 2 lamp fixtures
NOTE: All 2 Ft. T5 / T5HO fixtures use voltage specific instant start ballasts. CAN SHIP VIA UPS 2 Ft. & 4 Ft. ONLY
T5: 14W, 28W*T5HO: 24W, 54WT8: 17W, 32W, 59W*T8HO: 86W* (8’ fixture only)
1L (4' only)2L3L4L6L
248
UNV:Universal Voltage120: 120V277: 277V347: 347V
PR: Polycarbonate Ribbed Lens (Std)A: Acrylic Ribbed Lens (4’ 2 or 3 Lamp & 8’ only)AC: Acrylic Optically Clear Lens (4’ 2 or 3 lamp & 8’ only)FA: Frosted Acrylic Lens (4’ 2 or 3 lamp and 8’ only) (Not NSF listed)
SL: Stainless Steel LatchesHB: Enhanced Alum. Refl. 0.30” => 93% reflectiveEM: Emergency Battery Back up BallastWD: Wide distribution enhanced aluminum reflector (Used with AC lens ONLy) (4’ 2 lamp fixture, 8’ fixture w/ (2) 8’ lamps or 8’ fixture w/ (4) 4’ lamps only)
OPTIONSSERIES LAMP TyPE LAMP QTy LENGTH (Ft.) VOLTAGE LENS
LDPI, Inc. stocks multiple configurations. Consult factory.LAMPS SOLD SEPARATELy
376 SERIES376 SERIESW E T / D A M P L O C AT I O N S
Diffuser/Lens depth: 2.13”AC and FA lens depth: 3.5”
AC and FA acrylic lens
5.75”
STANDARD MOUNTING BRACKET (Included with each fixture) P/N: 5080 1 lamp housing P/N: 5081 2 or 3 lamp housing *Two brackets required per fixture
376
Chain hung mounting option
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
31
The 379 Series is a perfect fixture for a multitude of applications desiring a wet/damp fixture or an enclosed high bay fixture. The 379 is a glass fiber reinforced product with injection molded lens options for precise detail and strength. The lenses also have frosted ends, lineal prism sides and an optically clear face for maximum photometric output. All hardware is stainless steel. The gear tray hinges at both sides with tool-less latches for ease of accessibility and maintenance. Ask us about our customized performance reflector option. Lamps not included.
LISTINGS: UL 1598 listed U.S. and Canada for wet locations 5 lamp: Tested for 270 watts @ 40 C 6 lamp: Tested for 378 watts @ 25 C NSF: Splash zone non-food preparation NEMA 4X High pressure 1500 PSI tested For information on the IP code see page 130. For chemical resistance information see page 131.
FEATURES: Glass fiber reinforced polyester 5VA flammability rating Suitable for outdoor and Indoor use Closed cell polyurethane gasket with no seams Standard V hook mounting
LENS: Impact resistant acrylic 91.5% transmission Optional UV stabilized polycarbonate 87% transmission
ELECTRICAL: Available in 28, 32, 44, and 54 watts in T5, T8, T8HO, T5HO lamps. Voltages of 120, 277, 347 and 480. OPTIONS: ALL OPTIONS ORDERED SEPARATELy Enhanced aluminum reflector Emergency backup ballast Cable mount - cable not included Ceiling mount kit Tamper resistant Custom performance reflector (special request)
Warehouses, Paper MillsParking Garages, Tunnels
Locker RoomsWater Treatment Plants
Kitchens, ShowersFood Processing
Marinas/Offshore FacilitiesBreweries and BottlingLivestock ContainmentHospitals and Schools
379 SERIES379 SERIESW E T / D A M P L O C AT I O N S
WE
T/D
AM
P L
OC
AT
ION
SDIMENSIONS (Nominal)
IP67
6 1/16"
36"
14 9/16"
51 7/8"
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201232
www.ldpi-inc.com
MOUNTING
T5: 28WT8: 32W*T8HO: 44WT5HO: 54W*
3L4L*5L6L*
4 UNV1*: 120-277 Volts 50/60Hz 120: 120 Volts 60Hz 277: 277 Volts 60HzUNV2: 347/480 Volts 50/60 Hz - T5HO ONLY
Diffuser Type:A: Acrylic*P: Polycarbonate
HB: Reflector EM: Emergency Backup BallastCM: Cable Mount Cable not includedTR: Tamper ResistantCR: Custom Performance Reflector System
OPTIONSSERIES LAMP TyPE LAMP QTy LENGTH (Ft.) VOLTAGE LENS
* Standard fixture configurations
379 SERIES379 SERIESW E T / D A M P L O C AT I O N S
6 1/2”
4 1/2”
1 1/4” between ceiling and housing for heat dissipationAttaches directly to the ceiling!Mounting holes on the 6986 ceiling mount kit are 1/4” X 1/2” oval with a measurement of 4” on center.
Ceiling mount kit: 6986Kit consists of (2) 6985 brackets
ADDITIONAL CEILING MOUNTS
379
7 5/16"
1 1/4"*
*BETWEEN CEILING AND HOUSING FOR HEAT DISSIPATION
2 3/8"
Ø 25/64"
Ø 25/64" X 1/2" SLOTS
STAINLESS STEEL SQUARE BEND U-BOLT2" SQUARE OD TUBING (BOTH ENDS)
STAINLESS STEEL CEILING MOUNTING BRACKET (BOTH ENDS)
STAINLESS STEEL U-BOLT FOR PIPE SIZE 1 1/2" (2" OD PIPE) (BOTH ENDS)
STAINLESS STEEL CEILING MOUNTING BRACKET (BOTH ENDS)
STAINLESS STEEL 3/8” ROD(BOTH ENDS)
STAINLESS STEEL CEILING MOUNTING BRACKET (BOTH ENDS)
Ceiling mount system kit: 8366: Stainless steel ceiling mounting brackets, sealing washer, 1/2” conduit hub, 1/2” conduit hub plug and stainless steel support plate. (Assembly required)
Ceiling mount system kit 8369 - 3 Ft. rodCeiling mount system kit 8368 - U boltCeiling mount system kit 8367 - Square bend U bolt
Standard V-hook mounting Stainless steel ceiling mount system
LAMPS SOLD SEPARATELy
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
33
The 379i Series is a perfect fixture for industrial applications desiring a wet/damp fixture or an enclosed high bay fixture. The 379i is a glass fiber reinforced product with injection molded lens options for precise detail and strength. The lenses also have frosted ends, lineal prism sides with frosted or optically clear face. All hardware is stainless steel with tamper resistant latches. The gear tray hinges at both sides with tool-less latches for ease of accessibility and maintenance. The 379i series comes standard with the V-hook mounting system with zinc plated mounting straps.Ask us about our customized performance reflector option. Lamps not included.
LISTINGS: UL 1598 listed U.S. and Canada for wet locations 5 lamp: Tested for 270 watts @ 40 C 6 lamp: Tested for 378 watts @ 25 C NSF: Splash zone non-food preparation NEMA 4X High pressure 1500 PSI tested For information on the IP code see page 130. For chemical resistance information see page 131.
FEATURES: 5VA flammability rating Suitable for outdoor and Indoor use Closed cell polyurethane gasket with no seams Standard plastic (acetal copolymer) latches
LENS: Impact resistant acrylic 91.5% transmission Optional UV stabilized polycarbonate 87% transmission Optically clear or frosted lens
ELECTRICAL: Available in 28, 32, 44, and 54 watts in T5, T8, T8HO, T5HO lamps. Voltages of 120, 277, 347 and 480. OPTIONS: ALL OPTIONS ORDERED SEPARATELy Enhanced aluminum reflector Emergency backup ballast Flexible ceiling mount kit Tamper resistant latches Custom performance reflector (special request) Stainless steel mounting straps (same as standard except stainless steel) Rigid ceiling mount for surface mounting or dual pendant (supplied by others) Stainless steel latches
Warehouses, Paper MillsParking Garages, Tunnels
Locker RoomsWater Treatment Plants
Kitchens, ShowersFood Processing
Marinas/Offshore FacilitiesBreweries and BottlingLivestock ContainmentHospitals and Schools
379i SERIES379i SERIESW E T / D A M P L O C AT I O N S
WE
T/D
AM
P L
OC
AT
ION
SDIMENSIONS (Nominal)
IP67
6 3/16"
12"36"
42"
8"
14 9/16"
52"
Frosted Lens
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201234
www.ldpi-inc.com
MOUNTING
T5: 28WT8: 32W*T8HO: 44WT5HO: 54W*
3L4L*5L6L*
4 UNV1*: 120-277 Volts 50/60Hz 120: 120 Volts 60Hz 277: 277 Volts 60HzUNV2: 347/480 Volts 50/60 Hz - T5HO ONLY
Diffuser Type:A: Acrylic*P: PolycarbonateFA: Frosted Acrylic
HB: Enhanced Aluminum Reflector EM: Emergency Backup BallastCM: Cable Mount (Cable not included)TR: Tamper Resistant LatchesCR: Custom Performance Reflector SystemRZ: Rigid Ceiling Mount (zinc plated)RS: Rigid Ceiling Mount (stainless steel)MS: Mounting Strap (stainless steel) For use with cable or chain (not included)SL: Stainless Steel Latches
OPTIONSSERIES LAMP TyPE LAMP QTy LENGTH (Ft.) VOLTAGE LENS
* Standard fixture configurations
379i SERIES379i SERIESW E T / D A M P L O C AT I O N S
1 1/4” between ceiling and housing for heat dissipation Attaches directly to the ceiling!Mounting holes on the 6986 ceiling mount kit are 1/4” X 1/2” oval with a measurement of 4” on center. Ceiling mount kit: 6986. Kit consists of (2) 6985 brackets.
ADDITIONAL CEILING MOUNTS
379i
7 5/16"
1 1/4"*
*BETWEEN CEILING AND HOUSING FOR HEAT DISSIPATION
2 3/8"
Ø 25/64"
Ø 25/64" X 1/2" SLOTS
STAINLESS STEEL SQUARE BEND U-BOLT2" SQUARE OD TUBING (BOTH ENDS)
STAINLESS STEEL CEILING MOUNTING BRACKET (BOTH ENDS)
STAINLESS STEEL U-BOLT FOR PIPE SIZE 1 1/2" (2" OD PIPE) (BOTH ENDS)
STAINLESS STEEL CEILING MOUNTING BRACKET (BOTH ENDS)
STAINLESS STEEL 3/8” ROD(BOTH ENDS)
STAINLESS STEEL CEILING MOUNTING BRACKET (BOTH ENDS)
Ceiling mount system kit: 8366: stainless steel ceiling mounting brackets, sealing washer, 1/2” conduit hub, 1/2” conduit hub plug and stainless steel support plate.
Ceiling mount system kit 8369 - 3 Ft. rodCeiling mount system kit 8368 - U boltCeiling mount system kit 8367 - Square bend U bolt
Standard V-hook mounting with zinc plated mounting straps Flexible stainless steel ceiling mount system
LAMPS SOLD SEPARATELy
Rigid Ceiling MountRZ: Zinc platedRS: Stainless steel
RZ or RS also used for: Dual Pendant Mounting (Pendants supplied by others)
316 Stainless Steel V-hook.UL rated for 4X fixture weight.Maximum fixture weight of 23lbs.
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
35
Paint Spray BoothsMarine OutdoorChemical Plants
Waste Water Treatment AreasOil Drilling Rigs, Refineries
Grain ElevatorsCoal & Dust Storage
380 SERIES380 SERIESE X P L O S I O N P R O O F L I G H T I N G
The 380 Series is a must for any explosive atmosphere location! This product has five different hub entries at each end, enabling the installer to wire the fixture at more desirable angles. Center ballast placement provides a more balanced fixture for ease of installation and weight distribution. The 380 Series is available in 2’ & 4’ lengths for 2, 3, & 4 lamp combinations in T5, T5HO, T8, & T8HO. Lamps included.
LISTINGS: UL 844 listed and labeled for hazardous locations: Class I, Division 1, Groups C and D; Class I, Division 2, Groups A, B, C and D Class II, Division 1 and 2, Groups E, F and G; Class III. UL 1598A listed and labeled - marine type lighting fixture - outside type (salt water) UL 1598A testing equivalent to NEMA 4X requirements for hose-down & corrosion resistance. UL listed 1598 UL listed and labeled for use inside paint spray booths and rooms. Also meets requirements for National Fire Protection Association (NFPA) Standard 33 and National Electrical Code (NEC) Article 516. UL C approved and labeled Class I, Division 1, Group C and D Class I, Division 2, Groups A, B, C and D Class II, Division 1 and 2, Groups E, F and G; Class III. NEMA 3, 4X, 7CD, 9EFG. Simultaneous presence Class I and Class II Suitable for use inside paint spray booths. Class I, Zone 1, Group II A Class I, Zone 1, Group II B
FEATURES: Factory sealed, cast natural aluminum (U.S. Foundry) that is lightweight. Ballast mounted in the center for better balance and low profile. (5) 1/2” NPT Hubs located at 0 , 45 and 90 angles.
REFLECTOR: One piece painted aluminum reflector
LENS: .189" wall Borosilicate glass tubes
ELECTRICAL: Available in 14, 17, 24, 25, 28, 32, 35, 44, 54 and 60 watts 120-277 Volt (T5, T5HO & T8 only) 120 Volts (T8HO) 277 Volts (T8HO) 347 Volts (T5HO & T8 only)
OPTIONS: ALL OPTIONS ORDERED SEPARATELy Optional polycarbonate shield and stainless steel guard. EM: Emergency battery backup ballast - 4 Ft. 2 lamp ONLY 120 or 277V - MUST SPECIFY HB: 93% reflective specular reflector insert E
XP
LO
SIO
N P
RO
OF
LIG
HT
ING
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201236
www.ldpi-inc.com
WEIGHTS
4 Lamp 4 Ft. FixtureFixture Weight: 80#Shipping Weight: 84#
2 Lamp 2 Ft. FixtureFixture Weight: 30#Shipping Weight: 33#
2 Lamp 4 Ft. FixtureFixture Weight: 40#Shipping Weight: 43#
3 Lamp 4 Ft. FixtureFixture Weight: 45#Shipping Weight: 52#
2 Lamp 4 Ft. Fixture(EMERGENCy)Fixture Weight: 57#Shipping Weight: 60#
380 SERIES380 SERIESE X P L O S I O N P R O O F L I G H T I N G
2 Ft. WATTS 4 Ft. WATTST5 14 Watt T5 28 WattT5HO 24 Watt T5HO 54 WattT8 17 Watt T8 32 WattT8HO NA T8HO 44 Watt
LAMP WATTAGES Class I, DIV 1 Class I, DIV 2 Class II, DIV 1 Class III Simultaneous Groups Groups Groups PresenceFIXTURE C & D A, B, C, D E, F, G Class I & II
380 T6 = 85 C T4 = 135 C T4 = 135 C T4 = 135 C T4 = 135 C
Operating Temperature Codes Based on 40 C Ambient
SERIES380
T5**T5HO*†
T8*†
T8HO**
24† Voltage
120: 120 Volts220: 220 Volts 50 Hz277: 277 Volts347: 347 VoltsUNV: Universal Voltage†
120-277 50/60 Hz (Available for T5, T5HO and T8 ONLy)
2L: 2 Lamp†
3L: 3 Lamp†
4L: 4 Lamp† EM: Emergency Battery Back up Ballast (4 Ft. 2 lamp ONLY)
HB: 93% Reflective specular reflector insert
† Normally stocked Consult factory for non-standard fixtures
*5000K lamp standard for T5HO and T8 lamps**4100K lamp standard for T8HO and T5 lampsAll T5, T5HO & T8 are universal voltage**T8HO Lamp Type not available in 2 Ft. fixture.*347 Volt only available in T5HO and T8.3 and 4 Lamp fixtures not available in 2 Ft. length.3 lamp fixtures not available in T5 or T8HO
LAMP TyPE LAMP QTy LENGTH (Ft.) VOLTAGE OPTIONS
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 37
www.ldpi-inc.com
STAINLESS STEEL GUARDS
Description Catalog Number2-Lamp 2-Ft. Fixtures 44662-Lamp 4-Ft. Fixtures 42113-Lamp 4-Ft. Fixtures 45574-Lamp 4-Ft. Fixtures (2) 4211
POLYCARBONATE SHIELDS (+/- 1/16” thickness)
Description Catalog Number2-Lamp 2-Ft. Fixtures 44642-Lamp 4-Ft. Fixtures 42093-Lamp 4-Ft. Fixtures 44974-Lamp 4-Ft. Fixtures (2) 4209
UL 844, 924, 1598A, 1598Listed and labeled for hazardous locationsClass I Div. 1, Groups C & D, Class I Div. 2, Groups C & DClass II Div. 1 & 2, Groups E, F & G.Simultaneous presence of Class I & IIClass III, Class I, Zone 1, Groups IIA & IIBEmergency lighting equipment for hazardous locations.Non recessed marine luminaire, outside type (salt water).Lumen output varies per lamp selection.Equivalent to NEMA 4X requirements for hose-down & corrosion resistance.Listed and labeled for use inside paint spray booths and rooms.Meets requirements for NFPA 33 and NEC Article 516.NEMA 3, 4X 7CD, 9EFG.
FEATURES OF EMERGENCY BACK-UP BALLASTOnly available as 4 Ft. 2 lamp fixtureVented battery compartmentExplosion proof test switch and charging indicator lightMinimum starting temperature 0º C (32º F)Maintenance free emergency ballast/battery pack/charger575 Lumen operation3 year warranty
OPERATIONOperates normally on 120V, 277V, 60 Hz or 220V 50 HzWhen power fails the fixture automatically switches to emergency mode. In emergency mode one lamp will provide safe egress lighting for at least 90 minutes.The fixture switches to charging mode and resumes normal lighting once AC power is restored.
UL 595, 844, 924, 1598
Wall/Ceiling mount kitFor 4 lampP/N 4400Must be factory installed
Drop mount kit2 or 3 lamp P/N 44054 lamp P/N 4403
OPTIONS
MOUNTING OPTIONS
EMERGENCy BATTERy BACK-UP BALLAST
380 SERIES380 SERIESE X P L O S I O N P R O O F L I G H T I N G
Wall/Ceiling mount kitFor 2 or 3 lampP/N 4401
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201238
www.ldpi-inc.com
DIMENSIONS (Nominal)
48 7/8”
45 HUB
45 HUB
STDHUB
18 3/
4”
53 5/8”
7 1/4”
7 1/4”
90 HUB
4L 4FT. Dimensions
48 7/8”
45 HUB
45 HUB
STDHUB 13”
53 5/8”
7 1/4”
7 1/4”
90 HUB
48 7/8”
45 HUB
45 HUB
STDHUB
9”
53 5/8”7 1
/4”
7 1/4”
90 HUB
24 7/8”
45 HUB
45 HUB
STDHUB 9”
29 5/8”
7 1/4”
7 1/4”
90 HUB
2L 2FT. Dimensions
2L 4FT. Dimensions
3L 4FT. Dimensions
380 SERIES380 SERIESE X P L O S I O N P R O O F L I G H T I N G
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
39
Pendant Mount Ceiling Mount MUST have existing box
Box Mount Bracket/Box Mount
LISTINGS: UL 1598 listed U.S. and Canada Certified for wet locations.
FEATURES: Suitable for wet and non-hazardous locations Vapor proof incandescent/fluorescent light fixture Cast aluminum construction High temperat re sil o e inter al gaske Pr mium porce in s ck t with 50 C 8” ong lead attac ed
ELECTRICAL: 120 Volt Easy relamping with single thumb screw
REFLECTOR: Optional dome or angle reflector
MOUNTING: Available in pendant, ceiling, box or bracket/box mount Fixtures come standard with 1/2” hub size with 3/4” optional.
OPTIONS: ALL OPTIONS ORDERED SEPARATELy Colored globes Colored housings
The 381 Series is cast aluminum in construction that allows for 13-22 watts in compact fluorescent lamps or up to 300 watts in incandescent lighting using a medium base socket. The product is suitable for wet locations and vapor-proof, making it easy to hose down for cleaning if necessary. The 381 Series is available in four mounting options and has optional dome and angle reflectors. Always install fixture lamp base up. Lamps included with 13W and 22W fluorescent only.
Waste Water PlantsWater Treatment/Storage
Boiler RoomsFood Processing
Retail StoresCommercial ApplicationsWet and Damp Locations
Elevator Pits
381 SERIES381 SERIESVA P O R P R O O F L I G H T I N G
VA
PO
R P
RO
OF
LIG
HT
ING
Standard dome reflector100 Watt: P/N 3943200 Watt: P/N 3945
Direct light down with a dome reflector. Highly reflective finish over heavy gauge aluminum base. Field installation with 4 screws. Does not fit bracket/box mount.
6”15.2 cm
16”40.6 cm
Angle reflector100 Watt: P/N 3944200 Watt: P/N 3946
Direct light down and to the side with a 30 angle reflector. Highly reflective white epoxy finish over heavy gauge aluminum base. Field installation with 4 screws.
8.5”21.6 cm 12”
30.5 cm
DISCONTINUED
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201240
www.ldpi-inc.com
DIMENSIONS (Nominal)
NOTE:• 13W & 22W available in 120 volt only.• Globe options and colors available Consult factory for availability• Colored housing finishes available Consult factory for availability• Lamps included with fluorescent 13W and 22W fixtures ONLY
CAN SHIP VIA UPS
SERIES LAMP TyPE381
Wattage100: Max. 150W Incandescent.13: 13W Fluorescent200: Max. 300W Incandescent22: 22W Fluorescent
GUARD
DC: Die Cast
GLOBE
SG: Std Round Globe
MOUNT
4B: 4” BoxP: PendantC: CeilingBB: Bracket/Box
NOTE:100W Incandescent and 13W Fluorescent are the same measurement200W Incandescent and 22W Fluorescent are the same measurement
381 SERIES381 SERIESVA P O R P R O O F L I G H T I N G
Housing Finishes Available:Additional cost for optional colors
Natural - Standard
Silver Gray - Optional
White - Optional
Black - Optional
3 1 Penda t M unt4 1/4
10.8 m
100W9 5/8” (24.4 cm)200W11 15/16” (28.7 cm)
100W 4 1/8” (10.5 cm)
200W 5 3/8” (13.7 cm)
100 SeriesMax Watts150W Clear Glass100W Colored Glass75W Permaglobe
200 SeriesMax Watts200W Clear Glass150W Colored Glass100W Permaglobe
381 Ce ling Mount MUST ha e existing b x
100W7 1/4” (18.4 cm)200W9 1/8” (24 cm)
4 /4”10.8 cm
100W 4 1/8” (10.5 cm)
200W 5 3/8” (13.7 cm)
100 SeriesMax Watts100W Clear Glass100W Colored Glass75W Permaglobe
200 SeriesMax Watts150W Clear Glass100W Colored Glass100W Permaglobe
381 Bo Mo nt
100W9” (23 cm)200W10 3/4” (27.3 cm)
5 /8”13 cm
100W 4 1/8” (10 5 cm)
200W 5 3/8” (13.7 cm)
100 SeriesMax Watts150W Clear Glass100W Colored Glass75W Permaglobe
200 SeriesMax Watts300W Clear Glass200W Colored Glass100W Permaglobe
3 Br cket/Box Mount
100W9 5/8” (24.4 cm)200W11 1/4” (28.6 cm)
1 0W 7 1/8” (18.1 m)2 0W 8 1/8” (20 5 m)
100W 4 1/8” (10.5 cm)
200W 5 3/8” (13.7 cm)
100 SeriesMax Watts150W Clear Glass100W Colored Glass75W Permaglobe
200 SeriesMax Watts300W Clear Glass200W Colored Glass100W Permaglobe
DISCONTINUED
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
41
LISTINGS: Class I, Div. 1 and 2, Group C and D Incandescent Class II, Div. 1 and 2, Groups E, F and G Class III UL 844 listed U.S.
FEATURES: Explosion proof incandescent fixture for hazardous locations Ca t aluminum co struction with epox powder oat fi sh eat and impact si tant pr matic gl ss globe ith d c st gua d orrosion res sta
ELECTRICAL: 12 Volt Easy relamping with single thumb screw REFLECTOR: Optional dome or angle reflector
MOUNTING: Pendant, ceiling or bracket Comes standard with 4 hubs.
OPTIONS: ALL OPTIONS ORDERED SEPARATELy
250V AC MAX
The 383 Series is a fixture designed for Explosion-Proof and Hazardous environments. The cast aluminum housing is completed with a heat and impact resistant globe. This product handles incandescent sources up to 300 watts but is limited to 75 watts in paint spray booth applications and features a single thumb screw for easy re-lamping. This product has multiple listings from UL and is UL844 listed. Lamp not included.
Paint Spray BoothsWet/Damp Locations
Marine LocationsIndoor & OutdoorCorrosive Areas
383 SERIES383 SERIESE X P L O S I O N P R O O F I N C A N D E S C E N T
EX
PL
OS
ION
PR
OO
F I
NC
AN
DE
SC
EN
T
Standard dome reflector: P/N 3918
Angle reflector: P/N 3919
Direct light down with a dome reflector. Highly reflective finish over heavy gauge aluminum base. Field installation with 4 screws. Does not fit bracket mount.
Direct light down and to the side with a 30 angle reflector. Highly reflective white epoxy finish over heavy gauge aluminum base. Field installation with 4 screws.
4 hole box: P/N 3920-EXB shown
8 hole box: P/N 3921-EXJ1 shown
Explosion proof junction box for wiring or pendant fixture hanging. 4 NPT tapped hubs in sides. 3 close-up plugs provided. Blank, 1/2” or 3/4” tapped covers.
Explosion proof junction box for wiring or pendant fixture hanging. 6 tapped hubs in sides, 2 in bottom. 7 close-up plugs provided. Blank, 1/2” or 3/4” tapped covers.
Pendant Mount Ceiling Mount Bracket Mount
DISCONTINUED
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201242
www.ldpi-inc.com
DIMENSIONS (Nominal)
3 3 B acket Mo ntCom stan ard with 4 ole B x
16” 40.6 cm
7 1/4”18.4 cm
14 ” 35.8 cm
383 C iling MountCom s st nda d with Hole Box
15” 36.1 cm
7 1/4”18.4 cm
7 3/8” 18.7 cm
NOTE:• Standard Color: Gray
LAMPS SOLD SEPARATELy
Location Operating Without W/Std. Dome W/30° DomeClass, Div. Groups Temp. code Reflector Reflector ReflectorI 1 & 2 C & D T3C 300 300 300I 1 & 2 D T4A 75 – –II 1 & 2 E & F T3 200 150 200II 1 & 2 E, F & G T3C 100 – 150III – T3C 100 100 150
LISTINGS: Maximum Wattage
CAN SHIP VIA UPS
3 3 Pe dant Mount
13 1/4” 33.6 cm
7 1/4”18.4 cm
383 SERIES383 SERIESE X P L O S I O N P R O O F I N C A N D E S C E N T
P: PendantC: CeilingB: Bracket
50: 1/2” NPT75: 3/4” NPT G: Standard
SERIES MOUNT HUB SIZE GUARD
383
8 Hub box with 1/2” NPT cover tap3921-EXJ1
Optional Mounting Hubs
4 Hole BoxExplosion Proof junction box for wiring. With cover tap it allows pendant fixture hanging. 4 NPT tapped hubs in sides. 3 close-up plugs provided. Blank, 1/2" or 3/4" NPT tapped covers. Standard Box 4 hubs - Blank cover
Optional Box 8 hubs 1/2" NPT cover
4 Hub box with 1/2” NPT cover tap 3920-EXB1
8 Hole BoxExplosion Proof junction box for wiring. With cover tap it allows pendant fixture hanging. 6 NPT tapped hubs in sides, two in bottom. 7 close-up plugs provided. Blank, 1/2" or 3/4" NPT covers.
Cover 1/2" NPT 3/4" NPTTap Side Hubs Side Hubs
Blank 3920-EXB 3920-EXB-3/41/2" 3920-EXB1 3920-EXB1-3/43/4" 3920-EXB2 3920-EXB2-3/4
Cover 1/2" NPT 3/4" NPTTap Side Hubs Side Hubs
Blank 3921-EXJ 3921-EXJ-3/41/2" 3921-EXJ1 3921-EXJ1-3/43/4" 3921-EXJ2 3921-EXJ2-3/4
DISCONTINUED
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
43
Meets all Coast Guard specifications. Streamlined design provides eye appeal and ruggedness. Designed to withstand strong vibration. Adjustable mounting brackets and lamps included.Straight in lamp holders.
LISTINGS: UL 844: Class I, Div. 2, groups A, B, C and D. T4 (135 C) operating code UL 1598A: Outdoor marine type (saltwater)
FEATURES: Corrosion resistant, low copper content aluminum Zinc plated latches are standard 3/4" hubs Neoprene gasket Easy access to fluorescent ballast and internal wiring. For chemical resistance chart for the 384 Series see page 132.
LENS: 1/8” Clear acrylic lens is heat and shatter resistant.
MOUNTING: Versatile mounting arrangements. Brackets come standard
ELECTRICAL: Available in AC Available in 17, 24, 32 and 54 watts T5HO and T8 Voltages: 120, 220 and 120-277
OPTIONS: ALL OPTIONS ORDERED SEPARATELy EM: Emergency battery backup ballast (4' fixture only) Stainless steel latches
Pit LightingLaboratory Applications
Washdown AreasPetrochemical Plants
Chemical PlantsMaintenance PitsOil Drilling Rigs
Machining/FabricatingWaste Water Treatment Areas
384 SERIES384 SERIESM A R I N E L O C AT I O N S
MA
RIN
E L
OC
AT
ION
S
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201244
www.ldpi-inc.com
DIMENSIONS (Nominal)
384 SERIES DIMENSIONS (INCHES) A B C D WEIGHT VOLUME4 Ft. 51.6 50.0 6.3 6.5 32# 1.55 Cu. Ft.2 Ft. 26.0 26.0 6.3 6.5 23# .78 Cu. Ft.
A
B
C
D
Adjustable Mount Bracket Detail
2”
1 3/4”
4 5/8”
6”
Versatile mounting arrangements, (360 ).Brackets come standard
MOUNTING (STANDARD)
ADJUSTABLE MOUNTING BRACKETS AND LAMPS INCLUDED(Multiple voltages available, consult factory)
CAN SHIP VIA UPS
384 SERIES384 SERIESM A R I N E L O C AT I O N S
T5HO: 54W or 24WT8: 17W or 32WPL40: PL-L 40W CFL
2: 2 Ft.4: 4 Ft.
UNV1: Universal 120-277V120: 120V277: 277V
2L: 2 lamps
SERIES LAMP TyPE LAMP QTy VOLTAGELENGTH (Ft.) OPTIONS384
EM: Emergency Battery Backup (4' fixture only)
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
45
LISTINGS: UL 1598 listed U.S. and Canada Certified for wet locations.
FEATURES: Vapor proof compact fluorescent light fixture High t perature ilicone int rnal g k t Weatherproof bal s box Die cast alum num for uper r quality FL: Compa t flu resce t High press e so um Metal halide
HOUSING: Die cast aluminum with brass screws
REFLECTOR: Highly reflective white baked polyester epoxy powder finish over a heavy gauge aluminum base. Reflectors thread onto fixtures. (Ceiling mount only)
MOUNTING: Available in ceiling and bracket/box mount
ELECTRICAL: Available in 13, 26, 32, 35, 42, 50, 70 and 100 watt in Fluorescent, high pressure sodium and metal halide lamps. Voltages: 120, 208, 240 and 277 Easy relamping with single thumb screw
OPTIONS: ALL OPTIONS ORDERED SEPARATELy Colored globes Colored housings
The 387 Series is cast aluminum in construction that allows for 13, 26, 32 and 42 watts in CFL (compact fluorescent) lamps; 35, 50, 70, or 100 watts HID in HPS (high pressure sodium) lamps and 50, 70 or 100 watts of HID for MH (metal halide) lamps. The product is suitable for wet locations. It is vapor proof making it easy to hose down for cleaning if necessary. The 387 Series has a prismatic glass globe for even light distribution and is available in ceiling or wall mounting options with optional dome and angle reflectors. Lamp Included.
Facility EntrancesLoading Docks
Waste Water Treatment AreasWater Treatment/Storage
Food ProcessingTunnelsRetail
Utility AreasElevator Pits
387 SERIES387 SERIESVA P O R P R O O F C F L / H I D L I G H T I N G
VA
PO
R P
RO
OF
CF
L/H
ID L
IGH
TIN
GStandard dome reflector: P/N 3943
Direct light down with a dome reflector. Highly reflective finish over heavy gauge aluminum base. Field installation with 4 screws. Does not fit bracket/box mount.
6”15.2 cm
16”40.6 cm
Angle reflector: P/N 3944
Direct light down and to the side with a 30 angle reflector. Highly reflective white epoxy finish over heavy gauge aluminum base. Field installation with 4 screws.
8.5”21.6 cm 12”
30.5 cm
DISCONTINUED
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201246
www.ldpi-inc.com
DIMENSIONS
387 HID Ceili g M unt7 1/2”
(19 cm)
13 1/4” (33.6 cm)
3 7 CFL C iling Mount
A:9 3/4” (24.7 cm)B:12” (30.5 cm)
6” (15 2 cm)387 FL racket Moun
A: 7 7/8” (20 cm)B: 8 1/2” (22 cm)
A:10 3/8” (26 cm)B:12 1/2” (32 cm)
7 1/2”(19 cm)
7 1/2”(19 cm)
13 1/4” (33.6 cm)
38 HID Bra ket Mount10”
(25.4 cm)
A: 13 & 26WB: 32 & 42W
CB: Ceiling/BoxBB: Bracket/Box 120: 120 Volt
35W HPS onlyDT: Dual Tap (120 & 277 Volt: 50W HPS only)QT: Quad Tap (120, 208, 240 & 277 Volt)
SG: Std Round GlobeSize Wattage13: 13W Quad Tube26: 26W Triple Tube32: 32W Triple Tube42: 42W Triple Tube35S: 35W HPS*50S: 50W HPS*70S: 70W HPS*100S: 100W HPS*50H: 50W MH**70H: 70W MH**100H: 100W MH**
* HPS: High Pressure Sodium** MH: Metal Halide
SERIES MOUNT LAMP TyPE GLOBEVOLTAGE GUARD
NOTE:Lamps are included with fixtures• Standard color: natural unpainted finish• Globe options and colors available Consult factory for availability and pricing• Colored housing available Consult factory for availability and pricing
387 SERIES387 SERIESVA P O R P R O O F L I G H T I N G
387
DC: Die Cast (All fixtures come standard with guard)
Housing Finishes Available:Additional cost for optional colors
Natural - Standard
Silver Gray - Optional
White - Optional
Black - Optional
DISCONTINUED
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
47
When reliable lighting is required with the ability for instant on and long life, the Induction Series is right for the job! This classified product is perfect for those hard to get to places that are abundant in many facilities. This product has an automatic switch off in case of failure, provides warm white light and has exceptional energy efficiency. Designed to operate in ambient temperatures of -40 C to +40 C and will retrofit to existing LDPI “H Series” applications.
LISTINGS: Class I Division 2 Groups A,B,C,D Class I Zone 2, Groups IIA, IIB, IIC Class II Division 1 & 2 Groups E, F, G Class III UL 844 listed U.S. and Canada for hazardous locations Listed for wet locations, NEMA 4X
FEATURES: 60,000+ hour lamp life Reduced maintenance/re-lamp operations Instant on-instant restrike Automatic switch-off in case of failure Warm white light Exceptional energy efficiency -40 C to 40 C ambient operating range Retrofits into existing H Series applications Acceptable for use with infrared remote control equipment operating at 36kHz RFI approved for environments up to 1000 Mhz (FCC part reference luminaire)
ELECTRICAL: Available in 165 watt induction lamp Voltages: 120, 208, 240, 277 and 347 OPTIONS: ALL OPTIONS ORDERED SEPARATELy UNIPAK® (assembled fixture) HazCote™ (consult factory on lead time)
Marine LocationsWaste Water Treatment Areas
Offshore PlatformsChemical Plants
Steel Mills, RefineriesMachining Areas
Coal & Dust ApplicationsParking Garages
INDUCTION SERIESINDUCTION SERIESW E T / M A R I N E L O C AT I O N S
WE
T/M
AR
INE
LO
CA
TIO
NS
Reduce maintenance costs with LDPI, Inc. Induction Lighting:• Eliminates the need for expensive HID options such as quartz auxiliary lamps or instant restrike.• Reduces risk to installers performing maintenance in hard-to-reach places.• Reduces number of times necessary to de-energize entire circuit of lights for maintenance in hazardous locations.• Increases efficiency by decreasing machine shutdown time.• Lowers cost of expensive rental of scissor lifts or bucket trucks.
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201248
www.ldpi-inc.com
DIMENSIONS (Nominal)
D:WetMarine
I: Induction
SERIESD
0: STD Fixture
16: 165W Induction Lamp
E: Electronic Induction Ballast
12: 120V 60 Hz06: 208/240/277V 50 or 60 Hz34: 347V 60 Hz CSA
L: Lg. Tank R5G: Type V Refractor with Wire GuardR5: Type V Refractor
A2: 3/4” Cone Top PendantA3: 1” Cone Top PendantB2: 3/4” Wall MountB3: 1” Wall MountC2: 3/4” Ceiling MountC3: 1” Ceiling MountF2: 3/4” Flexible PendantF3: 1” Flexible PendantHV1: Hazvertor™ Ring Class I Div. 2HV2: Hazvertor Ring Class II Div. 1L4: 1-1/4” Straight StanchionL5: 1-1/2” Straight StanchionP2: 3/4” Rigid PendantP3: 1” Rigid PendantS4: 1-1/4” 25 Deg. StanchionS5: 1-1/2” 25 Deg. Stanchion
LAMPI
STARTER0
WATT16
BALLASTE
VOLTAGE HOUSINGL
OPTICAL MOUNT FINISH UNIPAKE
T: HazCote™ ** E: UNIPAK®
with lamp*
26"(660)
13 3/8"(340)
13 3/8"(340) 13 3/8"
(340)
143/8"(365)97/8"
(251)
14 7/8"(378)
221/8"(562)
24 3/8"(619)
115/8"(295)
211/2"(546)
Rigid Pendant Cone Pendant Ceiling Wall
23"(584)
23"(584)
161/8"(410)
15 3/4"(400)
233/8"(594)
133/8"(340)
25° Stanchion Straight Stanchion HazVertor™ Ring
INDUCTION SERIESINDUCTION SERIESW E T / M A R I N E L O C AT I O N S
* See page 53** See page 54
OPTIONAL
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
49
LISTINGS: Class I Div. 2 Groups A, B, C, D Class II Div. 1 & 2 Groups E, F, G Class III Div. 1 & 2 UL 844 listed U.S. for hazardous locations UL 1598A listed U.S. for marine locations NEMA 4X
ELECTRICAL: HPS (50 to 400 watts) MH - pulse start (70 to 400 watts) Voltages: 120, 208, 220, 240, 277, 347 and 480
HOUSING: Cast copper-free aluminum with powder coated finish - standard color beige.
GUARD: Polymeric, aluminum, or steel wire
GLOBE: 5 1/2” or 7 3/4” Dia. heat resistant 7 3/4” IES Type I, III or V, 12” Dia. IES Type II, V, (5 1/2” thread) 12” Dia. IES Type II, V (7 3/4” thread)
MOUNTING: Rigid or flexible pendant, ceiling, Wall or cone pendant 25 stanchion, Straight stanchion, HazVertor™ ring mount
OPTIONS: ALL OPTIONS ORDERED SEPARATELy Stainless steel inserts Auxiliary quartz lamp Fuse block UNIPAK® (assembled fixture) HazCote™ (consult factory on lead time)
MOUNT OPTIONS
Pendant FlexPendant
CeilingCone Wall
The H.I.D. H Series has a powder coat finish over a cast copper-free aluminum housing designed for hazardous environments. The product is available in wattages of 50 – 400W and H.I.D. lamp choice of MH (metal halide) or HPS (high pressure sodium).Perfect for a multitude of applications such as chemical plants, automobile manufacturing and marine and coastal facilities, this fixture carries many CSA and UL listings. The H.I.D. H Series also has an assortment of options from reflector choices, auxiliary quartz lamp and a 3-sided exit sign attachment. Don’t forget the UNIPAK® option that provides a fully assembled product for ease of installation!
H.I.D. H SERIESH.I.D. H SERIES5 0 - 4 0 0 W H A Z A R D O U S L O C AT I O N S
50
-40
0W
HA
ZA
RD
OU
S L
OC
AT
ION
S
MORE APPLICATIONSOil Refineries
Paint, Rubber ManufacturingOffshore Platforms
Oil, Gas TransmissionElectronics Manufacturing
Pharmaceutical PlantsAircraft Manufacturing
Grain Handling, Food ProcessingAmmunition Manufacturing
Pulp and Paper ManufacturingCopper, Aluminum Smelting
Steel Mills, FoundriesGeneral Manufacturing Plants
Chemical PlantsPetrochemical PlantsAutomobile Assembly
Marine/Coastal FacilitiesWaste Water Treatment Areas
Power Plants
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201250
www.ldpi-inc.com
All fixtures are for use with mogul base lamps except for 150 watt metal halide fixtures that use med. base lamps.
Lamps are not included unless “UNIPAK® with lamp” packaging is specified.
To order fixtures with “UNIPAK® with lamp” packaging add “E” to the end of the catalog number.
FOR UNIPAK® SEE PAGE 53FOR HazCote™ SEE PAGE 54FOR HAZVERTOR™ RING SEE PAGE 53OPTIONS AND COMPONENTS SEE PAGES 54 - 55DIMENSIONS SEE PAGES 57 - 58T-RATINGS SEE PAGES 59 - 60
*High pressure sodium (50 to 400 watts) Metal halide (70 to 400 watts)
Optical Refractor Types
For representational purposes only** Adding quartz restrike will be Class I Div. 2 ONLy with a T rating of 625 C
Voltage/Freq.03: 120/277 Volt, 60 Hz04: 120/208/240/277 Volt, 60 Hz09: 120/240/347 Volt, 60 Hz (CSA)12: 120 Volt, 60 Hz27: 277 Volt, 60 Hz48: 480 Volt, 60 Hz225: 220 Volt/50 Hz245: 240 volt, 50 Hz
Optical Assembly OptionsFor Std. Housing Fixtures (5-1/2” Thread)TG: Thermal Shock Resist. GlobeTGL: TG with Polymeric GuardSG: Tuffskin® Coated GlobeSGL: SG with Polymeric GuardR2: 12” Glass Refractor, Type IIR5: 12” Glass Refractor, Type VR2G: R2 with Wire GuardR5G: R5 with Wire Guard
For Refr. Globe Housing Fixtures (7-3/4” Thread)R1: 7 3/4” Refractor Globe, Type IR3: 7 3/4” Refractor Globe, Type IIIR5: 7 3/4” Refractor Globe, Type VR1P: R1 with Polymeric GuardR3P: R3 with Polymeric GuardR5P: R5 with Polymeric GuardTG: 7 3/4” Thermal Shock Res. GlobeTGP: TG with Polymeric Guard
For Large Housing Fixtures (7-3/4” Thread)TG: Thermal Shock Resist. GlobeTGC: TG with Cast Alum. GuardSG: Tuffskin® Coated GlobeSGC: SG with Cast Alum. GuardR2: 12” Glass Refractor, Type IIR5: 12” Glass Refractor, Type VR2G: R2 with Steel GuardR5G: R5 with Steel GuardRCB: Enclosed High Bay ReflectorRCG: RCB with Steel Wire Guard
Mounting styleA2: 3/4” Cone Top PendantA3: 1” Cone Top PendantB2: 3/4” Wall MountB3: 1” Wall MountC2: 3/4” Ceiling MountC3: 1” Ceiling MountF2: 3/4” Flexible PendantF3: 1” Flexible PendantHV1: HazVertor™ Ring - CI, D2HV2: HazVertor™ Ring - CII, D1L4: 1 1/4” Straight StanchionL5: 1 1/2” Straight StanchionP2: 3/4” Rigid PendantP3: 1” Rigid MountS4: 1 1/4” 25 Angle StanchionS5: 1 1/2” 25 Angle Stanchion
Special Finish OptionT: HazCote™ Custom Corrosion Coating.
UNIPAK® Packaging OptionsE: w/ Clear LampD: w/ Dual Arc Lamp (HPS only)U: Unlamped
See NOTE for UNIPAK® packaging options WITH reflectors
Fusing OptionsF: Single Fuse Block with FuseFF: Double Fuse Block with Fuse
CSA Cert.C: CSA Nameplate (consult factory)
HOUSINGSERIES LAMP STARTER WATT BALLAST VOLTAGE OPTICAL MOUNT FINISH UNIPAK FUSING CSA
Ballast Housing Style0: Standard Housing (150W HPS, 250W MH max.)R: Refractor Globe Housing (150W HPS, 250W MH max.)L: Large Housing (200-400W HPS; 400W MH)S: Standard Housing w/Stainless Steel InsertsI: Refractor Globe Housing w/Stainless Steel InsertsM: Large Housing w/Stainless Steel Inserts
Series:D: HID HazardousLocation Fixture
Lamp Wattage*05: 50W07: 70W10: 100W15: 150W17: 175W20: 200W25: 250W40: 400W
Lamp Type:S: High Pressure SodiumHP: Metal Halide - Pulse Start
Starter Circuit/Quartz0: Standard FixtureQ: Quartz Auxiliary Option**R: Instant StartJ: Auto Shutoff Starter
Ballast Circuit:H: High Reactance (≤150W)C: Constant Wattage Autotransformer(All ballast high power factor.)
H.I.D. H SERIESH.I.D. H SERIES5 0 - 4 0 0 W H A Z A R D O U S L O C AT I O N S
OPTIONAL
D
NOTE:H fixture with the "0" ballast housing: Standard reflector option (VR22P) use a "1" after UNIPAK® selection.30 angle reflector (VRA22P) use a "2" after UNIPAK® selection.
H fixture with the "R" or "L" ballast housing:Standard reflector option (VR31P) use a "1" after UNIPAK® selection.30 angle reflector (VRA31P) use a "5" after UNIPAK® selection.Deep dome reflector (VRD31) use a "6" after UNIPAK® selection.
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
51
LISTINGS: Class I Div. 2 Groups A, B, C, D Class II Div. 1 & 2 Groups E, F, G Class III Div. 1 & 2 UL 844 listed U.S. for hazardous locations UL 1598A listed U.S. for marine locations NEMA 4X, IP 66
ELECTRICAL: HPS (35 to 150 watts) MH - pulse start (70 to 100 watts) Fluorescent (9 to 26 watts) Incandescent (100 to 150 watts) Voltages: 120
HOUSING: Cast copper-free aluminum with powder coated finish - standard color beige.
GUARD: Cast aluminum, polymeric
GLOBE/REFRACTOR: Prismatic glass, high resistant prismatic glass, Type I, III or V IES refractor, green prismatic glass
REFLECTOR: Standard dome, 30 angle reflector, exit sign
MOUNTING: Rigid pendant, ceiling mount, 4” outlet mount, wall mount, 25 or 90 stanchion mount
MORE APPLICATIONSOil Refineries
Paint, Rubber ManufacturingOil, Gas Transmission
Electronics ManufacturingPharmaceutical PlantsAircraft Manufacturing
Grain Handling, Food ProcessingAmmunition Manufacturing
Pulp and Paper ManufacturingCopper, Aluminum SmeltingAutomobile Manufacturing
Marine and Coastal FacilitiesFoundries
General Manufacturing Plants
Pendant StanchionCeiling Wall
MOUNT OPTIONS
The H.I.D. H2 Series has a powder coat finish over a cast copper-free aluminum housing designed for hazardous environments. The product is available in wattages of 9 – 150W and H.I.D. lamp choices of MH (metal halide), HPS (high pressure sodium) and compact fluorescent or incandescent. Perfect for a multitude of applications such as waste treatment facilities, steel mills or offshore platforms, this fixture carries many CSA and UL listings. The H.I.D. H2 Series also has an assortment of options from reflector choices to globes & guards. Don’t forget the UNIPAK® option that provides a fully assembled product for ease of installation!
H.I.D. H2 SERIESH.I.D. H2 SERIES9 - 1 5 0 W H A Z A R D O U S L O C AT I O N S
9-1
50
W H
AZ
AR
DO
US
LO
CA
TIO
NS
Waste Water Treatment AreasSteel Mills
Offshore PlatformsShipyards, Shipbuilding
Utility Power PlantsBreweries, Malt Plants
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201252
www.ldpi-inc.com
FOR UNIPAK® SEE PAGE 53FOR HazCote™ SEE PAGE 54FOR OPTIONS AND COMPONENTS SEE PAGE 56FOR DIMENSIONS SEE PAGE 58FOR T-RATINGS SEE PAGE 60
Series:D: HazardousLocation
Lamp Holder TypeM: Medium Base Lamp holderB: Bi Pin Type (Fluorescent)
Lamp TypeS: High Pressure SodiumHP: Metal Halide - 100w maxF: FluorescentI: Incandescent
Ballast CircuitC: Constant Wattage Autotransformer (CWA)P: Reactor Type0: Incandescent Lamp No Ballast Circuit
Mounting StyleP2: 3/4” Rigid PendantP3: 1” Rigid PendantB2: 3/4” WallB3: 1” WallC2: 3/4” CeilingC3: 1” CeilingL4: 1 1/4” Straight StanchionL5: 1 1/2” Straight StanchionS4: 1 1/4” 25 Angle StanchionS5: 1 1/2” 25 Angle Stanchion
UNIPAK® OptionsE: Unipak with clear lampU: Unlamped
See NOTE for UNIPAK® packaging options WITH reflectors
Optical Assembly OptionTG: Tempered Globe Only (VGL 15)TGL: Tempered Globe and Polymeric GuardTGC: Tempered Globe and Cast GuardR1: Type I (long & narrow) Glass RefractorR3: Type III (asymmetric) Glass RefractorR5: Type V (symmetric) Glass RefractorR1P: Type I Refractor and Polymeric GuardR3P: Type III Refractor and Polymeric GuardR5P: Type V Refractor and Polymeric GuardR5A: 8” Glass Refractor (Type V)GCG: Green Glass Globe
Lamp Wattage09: 9W13: 13W18: 18W26: 26W03: 35W05: 50W07: 70W10: 100W15: 150W (HPS only)
Ballast Voltage120: 120 Volts
Special Coating OptionsT: HazCote™ Custom Corrosion coating on all Aluminum parts (consult factory)
FUSINGF: Single Fuse Block with Fuse (HID only)
SERIES LAMP HOLDER WATT BALLAST VOLTAGE OPTICAL MOUNT FINISH UNIPAK FUSING
Optical Refractor Types
For representational purposes only
H.I.D. H2 SERIESH.I.D. H2 SERIES9 - 1 5 0 W H A Z A R D O U S L O C AT I O N S
OPTIONAL
D
NOTE:H2 fixture with: Standard reflector option (VR15P) use a "1" after UNIPAK® selection.30 angle reflector (VRA15P) use a "2" after UNIPAK® selection.
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 53
www.ldpi-inc.com
UNIPAK® Packaging
LDPI® H.I.D. fixtures ordered with UNIPAK® packaging option will be completely assembled with lamp (and with mounting cover and/or reflector, if specified) and shipped in one carton. Each fixture assembly is foamed in place in the carton to insure zero transit damage. Receiving, handling, storing, identification, assembly and component matching are all made easier by this common sense approach to manufacturing and shipping.
Use catalog numbering codes (position #11) to add UNIPAK® with lamp packaging to any made-to-order H.I.D. assembly.
Benefits of UNIPAK® packaging:Fewer cartons to receiveFewer cartons to storeReduced job site material and handling costLower installation labor costNo chance of Lamp/Ballast mismatch in fieldNo waiting around for fixtures
HazVertor™ Adaptor Ring
The HazVertor™ Ring is a UL listed adapter ring which gives you the freedom to replace Crouse-Hinds® VMV, LMV and DMV series Champ® lighting fixtures with LDPI H.I.D. fixtures - without removing the Crouse-Hinds® mounting top hat from the conduit system.
Just look at the advantages:Increased energy efficiency and lumen output by upgrading from mercury vapor to metal halide or high pressure sodium.
Utilize threaded glass refractors for improved light distribution
Improved photometric performance in many cases.
Easy to order. Easy to install. UL listed. For use with H.I.D. marine, or hazardous environment fixture.Not available for the compact fixture.
H SERIES OPTIONSH SERIES OPTIONSM A R I N E A N D H A Z A R D O U S L O C AT I O N S
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201254
www.ldpi-inc.com
H.I.D. OptionsThe options listed below plus many moreare available with LDPI H.I.D. fixtures.
Instant Restart (50-150W HPS)Allows high pressure sodium lamp to be immediately restarted after a momentary power outage.
Auxiliary Quartz Circuit - AllFixtures use 120 volt 100W lamp quartz lamp circuit. Quartz lamp will operate during HID warm-up period, or when HID lamp cools down before restarting.
NEMA Lamp Wattage Decal - AllAdhesive back lamp wattage decal is provided on ballast housing exterior to clearly indicate wattagefor relamping and maintenance.
Auto Shutoff Option (50-150W HPS)Auto shutoff device prevents starter failure by disabling the starter circuit in case of cycling or defective HPS lamp.(not for use with instant restart option.)50 Hertz ballast (Most H.I.D. Fixtures)50 Hertz ballast in a variety of voltages can be furnished for international voltage systems.
Tuffskin® Coated Glass Globes (All globes)Tuffskin silicone coating contains glass particles in case of breakage, and prevents glass from contaminating process areas.
HazCote™ Custom Corrosion Resistant Coating (All)Custom chemical coating provides even higher degree of corrosion protection for cast aluminum parts. For use in highly corrosive environments.
Dual Arc Tube Lamps (HPS)Provide standby/immediate restart capabilities.
Stainless Steel Inserts (All)Stainless steel inserts for guard screws and ballast housing closure screw eliminate possibility of galvanic corrosion between stainless steel screws and aluminum parts.
UNIPAK® Packaging (All)UNIPAK® packaging means that fixtures are completely assembled - with lamp if specified - and foamed in one carton. Saves labor, handling, storage and reduces total installed cost per fixture.
HazVertor™ Adapter RingUL listed adapter ring enables quick, easy, UL listed retrofit of Crouse-Hinds® VMV, LMV and DMV series Champ® fixtures.Crouse-Hinds® and Champ® are registered
trademarks of Cooper Industries, Inc.
VGT22 VRF22C5 VGT31S VGL31R5 VRF31C5 VR31CB VGT31
VGU22P VGU22 VGR48 VGR48VGU31RP VGU31R
VR31P VR31PVRD31VRA31P
VGR64 VGU31
HV1 VP2 VF2
H3STANDARD
TANK
H3"R"
TANK
H3"L"
TANK
VA2 VC2 VB2 VS5 VL5
VR22P VRA22P VRA31P
H SERIES OPTIONSH SERIES OPTIONSM A R I N E A N D H A Z A R D O U S L O C AT I O N S
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 55
www.ldpi-inc.com
Mounting Hub Cat. Mounting Hub Cat.Style Size No. Style Size No.
REFLECTORS, EXIT SIGN
Cat.No.
Description
VR22P (see note)
VR31P(see note)
VRD31
VR31CB
VRA22P
(see note)
VRA31P(see note)
VRE22
Standard dome fiberglass Reinforced polyester.For use with standard housingStandard dome fiberglass reinforced polyester. For use with “R” and Lg. housingDeep dome anodized aluminum. For use with “R”and large housings. Must be line listed. Can not be UNIPAK®.
Enclosed high bay anodized aluminum with lens. For use with “R” or large housings30 angle reflector fiberglass reinforced polyester.For use with standard housing
Three sided exit sign.For use with standard housing
30 angle reflector fiberglass reinforced polyester. For use with “R” or Large housing
GLOBES, REFRACTORS
Cat.No.
Description
VGT22
VGT31S
VGT31
VGL31R1
VGL31R3
VGL31R5
VRF22C2
VRF22C5
VRF31C2
VRF31C5
5 1/2” dia. heat resistant globe For use with standard housing (250W max)7 3/4” dia. heat resistant globeFor use with “R” housing(250W max)7 3/4” dia. heat resistant globeFor use with large housing(400W max)7 3/4” IES Type I refractor globeFor use with “R” housing(250W max)7 3/4” IES Type III refractor globeFor use with “R” housing(250W max)7 3/4” IES Type V refractor globeFor use with “R” housing(250W max)12” dia. IES Type II refractor5 1/2” thread, for use with standard housing12” dia. IES Type V refractor5 1/2” thread, for use with standard housing12” dia. IES Type II refractor7 3/4” thread, for use with “R” and large housings12” dia. IES Type V refractor7 3/4” thread, for use with “R” and large housings
GUARDS Cat.No.
Description
VGU22P
VGU31RP
VGU31R
VGU31
VGR48
VGR64
Polymeric guard forVGT series globesPolymeric guard for VGT31Sglobe and VGL31R series refractor globes
Cast aluminum guard for VGT31S globe and VGL31R series refractor globesCast aluminum guard forVGT31 globe
Steel wire guard for allVRF series 12” refractors
Steel wire guard for VR31CB enclosed high bay reflector
MOUNTING COVERS
RigidPendant
Cone Pendant
FlexiblePendant
Ceiling
3/4”1”
3/4”1”
3/4”1”
3/4”1”
VP2VP3
VA2VA3
VF2VF3
VC2VC3
Wall
25Stanchion
StraightStanchion
HazVertorRing
3/4”1”
1 1/4”1 1/2”
1 1/4”1 1/2”
VB2VB3
VS4VS5
VL4VL5
HV2HV3
H SERIES OPTIONSH SERIES OPTIONSM A R I N E A N D H A Z A R D O U S L O C AT I O N S
NOTE:H or XP fixture with the "0" ballast housing: Standard reflector option (VR22P) use a "1" after UNIPAK® selection.30 angle reflector (VRA22P) use a "2" after UNIPAK® selection.
H or XP fixture with the "R" or "L" ballast housing:Standard reflector option (VR31P) use a "4" after UNIPAK® selection.30 angle reflector (VRA31P) use a "5" after UNIPAK® selection.
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201256
www.ldpi-inc.com
Mounting Hub Cat.Style Size No.
OUTLET BOXES Designed for CompactBallast Housings
RigidPendant
Ceiling
Wall
25Stanchion
90Stanchion
3/4”1”
3/4”1”
3/4”1”
1 1/4”1 1/2”
1 1/4”1 1/2”
VMP2VMP3
VMC2VMC3
VMB2VMB3
VMS2VMS3
VML4VML5
REFLECTORS, EXIT SIGN
Cat. No. Description
VR15P
VRA15P
VRE22VGE22
Standard domeFiberglass reinforced polyester
Three sided exit signFor use with standard housingRed or Green
30 angle reflectorFiberglass reinforced polyester
GLOBES, REFRACTORS
Cat. No. Description
VL15VGT15VGL15R1VGL15R3VGL15R5VRF22C5AVGT15G
Prismatic glass 150 watts max.Heat resistant prismatic glassIES Type I refractorIES Type III refractorIES Type V refractor8” IES Type V reflectorGreen prismatic glass
H2 SERIES OPTIONSH2 SERIES OPTIONSM A R I N E A N D H A Z A R D O U S L O C AT I O N S
GUARDS Cat. No. Description
VGU15 Cast aluminum - for use with glassglobes or refractors
Polymeric - for use withglass globes or refractors
For use with glass closed bottomrefractors, (8” dia.)
VGR32
VGU15P
NOTE:H2 or XP2 fixture with: Standard reflector option (VR15P) use a "1" after UNIPAK® selection.30 angle reflector (VRA15P) use a "2" after UNIPAK® selection.
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 57
www.ldpi-inc.com
13 3/4"
13 3/8" 13 3/8"
14 1/2"
13 3/8"
16 3/4"
14 7/8"
18 11/32"
13 3/8"
13 3/8"
14 3/4"
16 1/8"
15 3/16"
15 3/4"
15 3/16"
RIGID PENDANT FLEXIBLE PENDANT CONE PENDANT CEILING PENDANT
WALL MOUNT 25° STANCHION MOUNT STRAIGHT STANCHION HAZVERTOR™ RINGER
13 3/4"
STANDARD BALLAST HOUSING WITH GLOBE AND GUARD (Nominal)
STANDARD BALLAST HOUSING WITH 12” REFRACTOR AND GLOBE (Nominal)
FOR LARGE BALLAST HOUSING WITH GLOBE AND GUARD ADD 7 5/8” (7.625) TO HEIGHT MEASUREMENT
FOR LARGE BALLAST HOUSING WITH 12” REFRACTOR AND GLOBE ADD 4 3/16” (4.1875) TO HEIGHT MEASUREMENT
19 9/16"
14 7/8"
17 5/16"
13 3/8"
21 1/4"
13 3/8"
16 11/16"
13 3/8"
16 11/16"
13 3/8"
13 3/8"
17 9/16"
16 1/8"
18 1/8"
15 3/4"
18 1/8"
RIGID PENDANT FLEXIBLE PENDANT CONE PENDANT CEILING PENDANT
WALL MOUNT 25° STANCHION MOUNT STRAIGHT STANCHION HAZVERTOR™ RINGER
H SERIES DIMENSIONSH SERIES DIMENSIONSM A R I N E A N D H A Z A R D O U S L O C AT I O N S
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201258
www.ldpi-inc.com
"R" TANK HOUSING WITH 7 3/4” REFRACTOR AND GUARD DIMENSIONS (Nominal)"R" TANK HOUSING WITH 7 3/4” GLOBE AND GUARD DIMENSIONS (Nominal)
H.I.D. H2 SERIESMARINE AND HAZARDOUS LOCATION FIXTURES DIMENSIONS (Nominal)
13 3/8"
14 1/4"
13 3/8"
14 1/2"
13 3/8"
14 1/4"
13 3/8"
18 11/16"
14 7/8"
16 5/8"
RIGID PENDANT FLEXIBLE PENDANT CONE PENDANT CEILING PENDANT
WALL MOUNT 25° STANCHION MOUNT STRAIGHT STANCHION HAZVERTOR™ RINGER
15 3/4"
15 3/16"
16 1/8"
15 3/16"
13 3/8"
14 3/4"
RIGID PENDANT
9 5/8''
1 3/4''
4 3/16''
6 1/2''
CEILING PENDANT
WALL MOUNT
11''15 3/8''2''
4 9/16 '
4 3/16 '
6 11/16 '
15 7/8''
9 3/4''
25° STANCHION MOUNT
14 9 /16''
10 1 /4''
9 1 /4''
25°
2 7/8"
4 3/16"
6 1/2"
15 7/8"
14 9/16'' 10 1/4''
9 1/4''
2 7/8''
4 3/16''
6 1/2''
15 7/8''
90° STANCHION MOUNT
8 5/8 '
1 3/8''
4 3/16''
6 1/2''
H SERIES DIMENSIONSH SERIES DIMENSIONSM A R I N E A N D H A Z A R D O U S L O C AT I O N S
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 59
www.ldpi-inc.com
H.I.D. H SERIES CERTIFICATION GUIDE (40°C AMBIENT)STANDARD BALLAST HOUSING 5 1/2” THREAD
LAMPTyPE
HIGHPRESSURE
SODIUM
METALHALIDE
WATTS
5070100150
70100175250
AMBIENTTEMP(Deg. C)
40404040
40404040
CLASS I, DIV. 2 GROUP A, B, C, D
TEMPERATURE CODE
VGT/VGL22 5-1/2”Globe, Guard& Reflector
T3CT3AT2CT2A
T3CT3AT2AT2
VRF22C512” Dia.
Refractor
T4T3CT2DT2B
T3CT3AT2CT2
CLASS IIDIV. 1 & 2 GROUPS
VGT/VGL22 5-1/2”Globe, Guard and
Reflector
EFGEFGEFG
–
EFGEFG
––
VRF22C512” Dia.
Refractor
EFGEFGEFGEFG
EFGEFGEFGEFG
UL 595MARINE
yESyESyESyES
yESyESyES
–
NEMA 4X
yESyESyESyES
yESyESyESyES
SUPPLyWIRETEMP.
RATING(Deg. C)
85858590
607590125
NOTES: 1.) Simultaneous Presence Applications: Some H.I.D. H Series fixtures are UL Listed for simultaneous presence of gas and dust. Contact LDPI for specific information. 2.) Tuffskin® Coated Optics: Many H.I.D. Series H fixtures are UL Listed with Tuffskin® (silicone) coating on glass optics. Contact LDPI for specific information. 3.) For UL and CSA Certification Information on other ambient temperatures and fixture configurations, consult the factory. 4.) Consult factory for fixtures with higher ambient temperature ratings.
LAMPTyPE
HIGHPRESSURE
SODIUM
METALHALIDE
WATTS
5070100150
70100175250
AMBIENTTEMP(Deg. C)
40404040
40404040
CLASS I, DIV. 2 GROUP A, B, C, D
TEMPERATURE CODE
VGT31S 7-3/4”Globe, Guard& Reflector
T3CT3AT2DT2B
T3CT3AT2BT2
VGL31R57-3/4” Dia.Refractor
T3CT3AT3
T2B
T3CT3AT2BT2
CLASS IIDIV. 1 & 2 GROUPS
VGT31S 7-3/4”Globe, Guard and
Reflector
EFGEFGEFGEFG
EFGEFGEFGEF
VGL31R57-3/4” Dia.Refractor
EFGEFGEFGEFG
EFGEFGEFGEF
UL 595MARINE
yESyESyESyES
yESyESyES
–
NEMA 4X
yESyESyESyES
yESyESyESyES
SUPPLyWIRETEMP.
RATING(Deg. C)
60858585
757590125
NOTES: 1.) Simultaneous Presence Applications: Some H.I.D. H Series fixtures are UL Listed for simultaneous presence of gas and dust. Contact LDPI for specific information. 2.) Tuffskin® Coated Optics: Many H.I.D. Series H fixtures are UL Listed with Tuffskin® (silicone) coating on glass optics. Contact LDPI for specific information. 3.) For UL and CSA Certification Information on other ambient temperatures and fixture configurations, consult the factory.
H.I.D. H SERIES CERTIFICATION GUIDE (40°C AMBIENT)"R" TANK BALLAST HOUSING 7 3/4” THREAD
NOTE REGARDING GLASS GLOBES AND REFRACTORS — All LDPI fixture assemblies shown in the catalog as UL Listed and CSA Certified for Marine applications are suitable for hose-down when fixture is off and glass has been allowed to cool. Tempered glass globes and refractors have better thermal shock resistance properties than non-tempered globes and refractors and should be considered whenever fixtures are subject to being splashed with significantly cooler liquids while illuminated (hot). Consult factory for more information.
H SERIES T-RATINGSH SERIES T-RATINGSM A R I N E A N D H A Z A R D O U S L O C AT I O N S
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201260
www.ldpi-inc.com
H.I.D. H2 SERIES CERTIFICATION GUIDE (40°C AMBIENT)For UL844/595 listing at 40°C AMBIENT
NOTE REGARDING GLASS GLOBES AND REFRACTORS — All LDPI fixture assemblies shown in the catalog as UL Listed and CSA Certified for Marine applications are suitable for hose-down when fixture is off and glass has been allowed to cool. Tempered glass globes and refractors have better thermal shock resistance properties than non-tempered globes and refractors and should be considered whenever fixtures are subject to being splashed with significantly cooler liquids while illuminated (hot). Consult factory for more information.
SUPPLyWIRETEMP.
RATING(Deg. C)
9090110
110110
NOTES: 1.) Simultaneous Presence Applications: Some H.I.D. H Series fixtures are UL Listed for simultaneous presence of gas and dust. Contact LDPI for specific information. 2.) Tuffskin® Coated Optics: Many H.I.D. Series H fixtures are UL Listed with Tuffskin® (silicone) coating on glass optics. Contact LDPI for specific information. 3.) For UL and CSA Certification Information on other ambient temperatures and fixture configurations, consult the factory. 4.) Consult factory for fixtures with higher ambient temperature ratings.
H.I.D. H SERIES CERTIFICATION GUIDE (40°C AMBIENT)LARGE BALLAST HOUSING 7 3/4” THREAD
LAMPTyPE
HIGHPRESSURE
SODIUM
METALHALIDE
WATTS
200250400
250400
AMBIENTTEMP(Deg. C)
404040
4040
CLASS I, DIV. 2 GROUP A, B, C, D
TEMPERATURE CODE
VGT31Globe, Guard& Reflector
T2350 C
T2A
T2350 C
VRF31C512” Dia.
Refractor
T2A350 C
T2B
T2A325 C
CLASS IIDIV. 1 & 2 GROUPS
VR31CBReflector
w/lens
T2A350 C
T2B
T2A325 C
UL 595MARINE
yESyES
–
––
NEMA 4X
yESyESyES
yESyES
VGT31Globe, Guard& Reflector
T2350 C
T2A
T2350 C
VRF31C512” Dia.
Refractor
T2A350 C
T2B
T2A325 C
VR31CBReflector
w/lens
T2A350 C
T2B
T2A325 C
FIXTURETyPE
HIGHPRESSURE
SODIUM
FLUORESCENT
INCANDESCENT
WATTS
355070100150
9131826
60100150
SERIES
DSMDSMDSMDSMDSM
DFBDFBDFBDFB
DIMDIMDIM
CLASS I, DIV. 2 GROUP A, B, C, D
TEMPERATURE CODE
Globe,& GuardWith or W/O
Reflector
T3AT3
T2BT2A
325 C
T3CT3CT3CT3
T3T3
T2B
8” Refractor
T3AT3
T2BT2A
325 C
T3CT3CT3CT3
T3T3
T2B
CLASS IIDIV. 1 & 2 GROUPS
Globe,& GuardWith or W/O
Reflector
EFGEFGEFGEFEF
EFGEFGEFGEFG
EFEF–
8” Refractor
EFGEFGEFGEFGEFG
EFGEFGEFGEFG
EFGEFGEFG
UL 595MARINE
yESyESyESyES
–
yESyESyESyES
yESyESyES
NEMA 4X
yESyESyESyESyES
yESyESyESyES
yESyESyES
CLASS IIIDIV. 1 & 2
Globe,& GuardWith or W/O
Reflector
yESyESyES
––
yESyESyESyES
–––
8” Refractor
yESyESyESyESyES
yESyESyESyES
yESyESyES
H SERIES T-RATINGSH SERIES T-RATINGSM A R I N E A N D H A Z A R D O U S L O C AT I O N S
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
61
LISTINGS: Class I Div. 1 Groups C, D Class II Div. 1 & 2 Groups E, F, G UL 844 listed U.S. for hazardous locations UL 1598A listed U.S. for marine locations NEMA 4X
ELECTRICAL: HPS (50 to 400 watts) MH (70 to 400 watts)
FEATURES: H.I.D. explosion proof fixture Mogul base - except for 150 watt metal halide lamps that are medium base. 50-400W Voltages: 120, 208, 240, 277, 347 and 480
HOUSING: Cast copper-free aluminum with powder coated finish - standard color beige.
GUARD: Cast guard
REFLECTOR: Choice of standard dome, deep dome, angle reflectors.
MOUNTING: Pendant, ceiling, stanchion or wall/bulkhead mount
MOUNTING OPTIONS
Ceiling Pendant Wall/BulkheadStanchion
The H.I.D. XP Series has a powder coat finish over a cast copper-free aluminum housing designed for explosive and hazardous environments. The product is available in HPS (high pressure sodium) (50 to 400 watts) and MH (metal halide) (70 to 400 watts). This series is perfect for explosive and hazardous environments such as grain elevators, petrochemical plants, paint spray booths (100 watts max) and marine environments that call for Class I, Div. 1, Groups C & D or Class II, Div. 1 & 2, Groups E, F & G, UL 844 & 1598A listings. The H.I.D. XP Series also has an assortment of options from reflector choices, auxiliary quartz lamp and a 3-sided exit sign attachment. Don’t forget the UNIPAK® option that provides a fully assembled product for ease of installation!
Paint Spray BoothsGrain Elevators
Petrochemical PlantsChemical Plants
Marine ApplicationsHose-Down Locations
Laboratory Applications
H.I.D. XP SERIESH.I.D. XP SERIES5 0 - 4 0 0 W E X P L O S I O N P R O O F
50
-40
0W
EX
PL
OS
ION
PR
OO
F
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201262
www.ldpi-inc.com
*HPS (high pressure sodium) (50 to 400 watts) MH (metal halide) (70 to 400 watts)
Series:X: Explosion Proof
Quartz and Instant Restart Options0: Standard FixtureQ: Fixture w/Auxiliary Quartz optionR: Fixture with Instant Restart option (70, 100 and 150 HPS only)
HP Pulse Start - Leave Blank
Lamp TypeC: High Pressure Sodium (ANSI S-56 lamp)HP: Metal Halide - Pulse Start (100w max in a paint area)S: High Pressure Sodium
Ballast CircuitC: Constant Wattage Autotransformer (CWA)H: Reactance Type (≤ 150W)
Mounting StyleP2: 3/4” PendantP3: 1” PendantB2: 3/4” WallB3: 1” WallJ2: 3/4” BulkheadJ3: 1” BulkheadC2: 3/4” CeilingC3: 1” CeilingS4: 1 1/4” StanchionS5: 1 1/2” Stanchion
UNIPAK® OptionsE: Unipak with clear lampU: Unlamped
See NOTE for UNIPAK® packaging options WITH reflectors.
Lamp Wattage*05: 50W07: 70W10: 100W15: 150W17: 175W25: 250W40: 400W
Ballast Voltage020: 480 Volt with 120 Volt Tap*030: 120/277 Volt040: 120/208/240/277 Multi-tap120: 120 Volt480: 480 Volt340: 347 Volt
Special OptionsPS: UL listed fixture for paint spray areas (selected Wattages) 100W or lessT: HazCote™ Custom Corrosion coating on all aluminum parts (consult factory for lead time)PST: UL listed for paint spray areas with HazCote™.
GUARDG: Cast GuardOmit “G” if Guard not required
GUARDSERIES LAMP STARTER WATT BALLAST VOLTAGE MOUNT FINISH UNIPAK
FOR UNIPAK® SEE PAGE 53FOR HazCote™ SEE PAGE 54FOR OPTIONS AND COMPONENTS SEE PAGE 65FOR DIMENSIONS SEE PAGES 67 - 68FOR T-RATINGS SEE PAGE 69
H.I.D. XP SERIESH.I.D. XP SERIES5 0 - 4 0 0 W E X P L O S I O N P R O O F
FLOODLIGHT (Trunnion Mount) Class I, Div. 1 (consult factory for T-ratings)LAMP TYPE/WATTS CATALOG NUMBER: Includes: Fixture, trunnion and 3/4” conduit HIGH PRESSURE SODIUM 50 XS005H030 70 XS007H040-G-P2TRE 100 XS010H040-G-P2-TRE 150 XS015H040-G-P2TRE 250 XS025C040-G-P2TRE 400 XS040C040-G-P2TRE METAL HALIDE 175 XHP17C040-G-P2TRE 250 XHP25C040-G-P2TRE 400 XHP40C040-G-P2TRE
NOTE: Fixture shown with Dome Reflector and Guard.These are not included in the catalog number.Please see HID XP Accessories specific to Floodlighting.
HID XP SERIES FLOODLIGHT ACCESSORIES
ACCESSORIES CATALOG NUMBERAngle Reflector VRA31Dome Reflector VR31Cast Guard XGU44 (50-150 H.P.S., 175/250 M.H. or 100-250 M.V.)Cast Guard VGU 31 (250/400 H.P.S., 400 M.V. or 400 M.H.)Pole-Top Mount 9902 (slipfitter mounting). Fits 2" or 2 1/2" pipe (2" pipe intrudes 3 1/16"; 2 1/2" pipe intrudes 2 3/4".) Furnished with mounting bolts set screws
OPTIONAL
NOTE:XP fixture with:Standard reflector option (VR31P) use a "4" after UNIPAK® selection.30 angle reflector (VRA31P) use a "5" after UNIPAK® selection.Deep dome reflector (VRD31) use a "6" after UNIPAK® selection.
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
63
LISTINGS: Class I Div. 1 Groups C, D Class II Div. 1 & 2 Groups E, F, G 35-150W UL 844 listed U.S. for hazardous locations UL 1598A listed U.S. for marine locations NEMA 4X
ELECTRICAL: HPS (35 to 150 watts) Fluorescent (9 to 26 watts) Voltages: 120
HOUSING: Cast copper-free aluminum with powder coated finish
REFLECTORS: Choice of standard dome, angle reflectors.
GUARD: Cast guard
MOUNTING: Pendant Ceiling Wall Bulkhead Stanchion
MOUNTING OPTIONS
Pendant Ceiling Wall Bulkhead Stanchion
The H.I.D. XP2 Series has a powder coat finish over a cast copper-free aluminum housing designed for explosive and hazardous environments. The product is available in H.I.D. lamp choice of HPS (high pressure sodium) (35 – 150 watts). This series is perfect for explosive and hazardous environments such as grain elevators, petrochemical plants, paint spray booths (100 watts max) and marine environments that call for Class I, Div. 1, Groups C & D, or Class II, Div. 1 & 2, Groups E, F & G, UL 844 & 1598A listings. The H.I.D. XP2 Series also has an assortment of options from reflector choices to globes & guards. Don’t forget the UNIPAK® option that provides a fully assembled product for ease of installation!
Paint Spray BoothsGrain Elevators
Petrochemical PlantsChemical Plants
Marine ApplicationsHose-Down Locations
Laboratory Applications
H.I.D. XP2 SERIESH.I.D. XP2 SERIES3 5 - 1 5 0 W E X P L O S I O N P R O O F
35
-15
0W
EX
PL
OS
ION
PR
OO
F
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201264
www.ldpi-inc.com
FOR UNIPAK® SEE PAGE 53FOR HazCote™ SEE PAGE 54FOR OPTIONS AND COMPONENTS SEE PAGE 66FOR DIMENSIONS SEE PAGE 68FOR T-RATINGS SEE PAGE 70
*HPS (high pressure sodium) (35 to 150 watts)
GUARDSERIES LAMP HOLDER WATT BALLAST VOLTAGE MOUNT FINISH UNIPAK
Series:X: Explosion Proof
Lamp HolderM: Medium Base Lamp holder
Lamp TypeS: High Pressure Sodium
Ballast CircuitC: Constant Wattage Autotransformer (CWA)P: Reactor Type (HPF) (HPS Only)
Mounting StyleP2: 3/4” PendantP3: 1” PendantB2: 3/4” WallB3: 1” WallJ2: 3/4” BulkheadJ3: 1” BulkheadC2: 3/4” CeilingC3: 1” CeilingS4: 1 1/4” StanchionS5: 1 1/2” Stanchion
UNIPAK® OptionsE: Unipak with clear lampU: Unlamped
See NOTE for UNIPAK® packaging options WITH reflectors.
Lamp Wattage*03: 35W05: 50W07: 70W75: 75W10: 100W15: 150W
Ballast Voltage120: 120 Volt
Special OptionsPS: UL listed fixture for paint spray areas (selected Wattages)T: HazCote™ Custom Corrosion coating on all Aluminum parts (consult factory for lead time)PST: UL listed for paint spray areas with HazCote™.
GUARDG: Cast Guard Omit “G” if Guard not required
H.I.D. XP2 SERIESH.I.D. XP2 SERIES3 5 - 1 5 0 W E X P L O S I O N P R O O F
GUARDSERIES LAMP HOLDER WATT BALLAST VOLTAGE MOUNT UNIPAK
Series:X: Explosion Proof
Lamp HolderB: Bi-Pin/ PL lamp
Lamp TypeF: Fluorescent
Ballast CircuitP: Reactor Type (HPF)
Mounting StyleP2: 3/4” PendantP3: 1” PendantB2: 3/4” WallB3: 1” WallJ2: 3/4” BulkheadJ3: 1” BulkheadC2: 3/4” CeilingC3: 1” CeilingS4: 1 1/4” StanchionS5: 1 1/2” Stanchion
UNIPAK® OptionsD: Unipak with diffuse coated lamp
Lamp Wattage09: 9W13: 13W18: 18W26: 26W
Ballast Voltage120: 120 Volt
GUARDG: Cast Guard Omit “G” if Guard not required
COMPACT FLUORESCENT OPTION
Fluorescent fixtures use PL type lamps (one or two lamps included).GUARD: If a guard is not required delete one “G” from the catalog number.Verify Hazardous Location Certification with your requirements.
OPTIONAL
OPTIONAL
NOTE:XP2 fixture with:Standard reflector option (VR15P) use a "4" after UNIPAK® selection.30 angle reflector (VRA15P) use a "5" after UNIPAK® selection.
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 65
www.ldpi-inc.com
REPLACEMENT GLOBES
Cat. No. Description
XGSA44
XGSA44A
Replacement globe assembly50-250 wattsReplacement globe assembly400 watts
REFLECTORS Cat. No. Description
VR31P
VRD31
VRA31P
Standard domeFiberglass reinforced polyester
30 angle reflectorFiberglass reinforced polyester
Deep dome steel with anodized aluminum finish
GUARDS Cat. No. Description
XGU44
VGU31
Cast aluminum, powder finish
Used on all 400 watt fixtures and 250 watt HPS and MH fixtures.Cast aluminum, powder finish
Mounting Hub Cat.Style Size No.
OUTLET BOXES
Pendant
Ceiling
Wall
Bulkhead
Stanchion
3/4”1”
3/4”1”
3/4”1”
3/4”1”
1 1/4”1 1/2”
XP2XP3
XC2XC3
XB2XB3
XJ2XJ3
XS2XS3
XP SERIES OPTIONSXP SERIES OPTIONS5 0 - 4 0 0 W E X P L O S I O N P R O O F
NOTE:H or XP fixture with the "R" or "L" ballast housing:Standard reflector option (VR31P) use a "4" after UNIPAK® selection.30 angle reflector (VRA31P) use a "5" after UNIPAK® selection.Deep dome reflector (VRD31) use a "6" after UNIPAK® selection.
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201266
www.ldpi-inc.com
REPLACEMENT GLOBES Cat. No. Description
XGSA15 Replacement globe assembly35-150 watts
Mounting Hub Cat.Style Size No.
OUTLET BOXES
Pendant
Ceiling
Wall
Bulkhead
Stanchion
3/4”1”
3/4”1”
3/4”1”
3/4”1”
1 1/4”1 1/2”
XP2XP3
XC2XC3
XB2XB3
XJ2XJ3
XS2XS3
REFLECTORS Cat. No. Description
VR15P
VRA15P
Standard domeFiberglass reinforced polyester
30 angle reflectorFiberglass reinforced polyester
GUARDS Cat. No. Description
XGU15 Cast aluminum, powder finish
Exit sign: red or green
XP2 SERIES OPTIONSXP2 SERIES OPTIONS3 5 - 1 5 0 W E X P L O S I O N P R O O F
VRE22VGE22
NOTE:H2 or XP2 fixture with: Standard reflector option (VR15P) use a "1" after UNIPAK® selection.30 angle reflector (VRA15P) use a "2" after UNIPAK® selection.
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 67
www.ldpi-inc.com
WALL MOUNT WITH GLOBE AND GUARD
CEILING MOUNT WITH GLOBE AND GUARD
PENDANT MOUNT WITH GLOBE AND GUARD
BULKHEAD MOUNT WITH GLOBE, GUARD AND REFLECTOR
STANCHION MOUNT WITH GLOBE, GUARD AND REFLECTOR
PENDANT MOUNT WITH GLOBE, GUARD AND REFLECTOR
CE LING MOUNT WITH GLOBE, GUARD AND REFLECTOR
BULKHEAD MOUNT WITH GLOBE AND GUARD
WALL MOUNT WITH GLOBE, GUARD AND REFLECTOR
XP SERIES DIMENSIONSXP SERIES DIMENSIONS5 0 - 4 0 0 W E X P L O S I O N P R O O F
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201268
www.ldpi-inc.com
H.I.D. XP2 SERIES EXPLOSION PROOF FIXTURES
* TANK DIM: HPS 9” INCAN 7” FLUOR 5-11/16”
H.I.D. XP SERIES EXPLOSION PROOF (400 SERIES) FIXTURES
PENDANT MOUNT WITHGLOBE AND GUARD
STANCHION MOUNT WITHGLOBE, GUARD AND REFLECTOR
WALL MOUNT WITHGLOBE, GUARD AND REFLECTOR
CEILING MOUNT WITHGLOBE, GUARD AND REFLECTOR
RIGID PENDANT WITHGLOBE AND GUARD
CEILING MOUNT WITHGLOBE AND GUARD WALL MOUNT WITH
GLOBE GUARD AND 30ANGLE REFLECTOR
STANCHION MOUNT WITHGLOBE GUARD AND 30ANGLE REFLECTOR
WALL MOUNT WITHGLOBE AND EXIT SIGN ACCESSORy
CEILING MOUNT WITHGLOBE, GUARD ANDDOME REFLECTOR
XP SERIES DIMENSIONSXP SERIES DIMENSIONS5 0 - 4 0 0 W E X P L O S I O N P R O O F
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 69
www.ldpi-inc.com
NOTE REGARDING GLASS GLOBES AND REFRACTORS — All LDPI fixture assemblies shown in the catalog as UL listed and CSA certified for marine applications are suitable for hose-down when fixture is off and glass has been allowed to cool. Tempered glass globes and refractors have better thermal shock resistance properties than non-tempered globes and refractors and should be considered whenever fixtures are subject to being splashed with significantly cooler liquids while illuminated (hot). Consult factory for more information.
§ These fixtures suitable (UL listed) for use in paint spray areas. + UL listed at 25 C
H.I.D. XP SERIES CERTIFICATION GUIDE (40°C AMBIENT)
FIXTURETyPE
HIGHPRESSURE
SODIUM
METAL HALIDE
WATTS
50 §
70 §(With or 100 §Without 150 (S55)Instant 150(S56)Restart) 250 400
50
With 70Auxiliary 100Quartz 150(S55)
150(S56)
175250400
With 175Auxiliary 250Quartz
CLASS I, DIV. 1 GROUPS C & D
Rated Temp C
“T”No.
T6T6T5
T4AT4AT4AT3C
T4AT4AT3CT3CT3C
T4AT3CT3B
T3CT3A
CLASS IIDIV. 1 & 2
Rated Temp C
100120135160160
––
160160200200
–
180200
–
––
Groups
EFGEFGEFGEFGEFG
––
EFGEFGEFEF–
EFEF–
––
UL 595MARINE
yESyESyESyESyESyESyES
yESyESyESyESyES
yESyESyES
yESyES
NEMA 4X(Suitable
forHosedown)
yESyESyESyESyESyESyES
yESyESyESyESyES
yESyESyES
yESyES
CLASS IIIDIV. 1 & 2
yESyESyESyESyES
––
yESyES
–––
–––
––
8585
100120120120160
120120160160
160 +
120160165
160 +180 +
XP SERIES T-RATINGSXP SERIES T-RATINGS5 0 - 4 0 0 W E X P L O S I O N P R O O F
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201270
www.ldpi-inc.com
T - Number Table
T - NumberMaximum Temp. C
T1
T2
T2A
T2B
T2C
T2D
T3
T - NumberMaximum Temp. C
450
300
280
260
230
215
200
T3A
T3B
T3C
T4
T4A
T5
T6
180
165
160
135
120
100
85
NOTE REGARDING GLASS GLOBES AND REFRACTORS — All LDPI fixture assemblies shown in the catalog as UL listed and CSA certified for marine applications are suitable for hose-down when fixture is off and glass has been allowed to cool. Tempered glass globes and refractors have better thermal shock resistance properties than non-tempered globes and refractors and should be considered whenever fixtures are subject to being splashed with significantly cooler liquids while illuminated (hot). Consult factory for more information.
§ These fixtures suitable (UL listed) for use in paint spray areas. + UL listed at 25 C
H.I.D. XP2 SERIES CERTIFICATION GUIDE (40°C AMBIENT)
FIXTURETyPE
HIGHPRESSURE
SODIUM
INCANDESCENT
FLUORESCENT
WATTS
CLASS I, DIV. 1 GROUPS C & DCLASS I, Div. 2,
GROUPS A,B,C & D
Rated Temp C
8585
100120135
100120
8585
“T”No.
T6T6T5
T4AT4
T5T4A
T6T6
CLASS IIDIV. 1 & 2
Rated Temp C
100120135160
–
160200
8585
Groups
EFGEFGEFGEFG
–
EFGEF
EFGEFG
UL 595MARINE
yESyESyESyESyES
yESyES
yESyES
NEMA 4X(Suitable
forHosedown)
yESyESyESyESyES
yESyES
yESyES
CLASS IIIDIV. 1 & 2
yESyESyESyES
–
yES–
yESyES
35 §50 §70 §100 §150 +
100150
18 § +26 § +
XP2 SERIES T-RATINGSXP2 SERIES T-RATINGS9 - 1 5 0 W E X P L O S I O N P R O O F
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
71
H.I.D. FL SERIESH.I.D. FL SERIESF L O O D L I G H T S
FL
OO
DL
IGH
TS
Chemical PlantsOil Refineries
Waste Treatment FacilitiesFood Processing Plants
Steel FoundriesPower Plants
Pulp/Paper FacilitiesAirplane Manufacturing
LISTINGS: Class I, Div. 2, Groups A, B, C, D UL 844 listed U.S. for hazardous locations NEMA 3R Outdoor wet locations Temperature range: 70W-400W (all) -30 C to 40 C 1000W HPS -30 C to 40 C 1000W MH -30 C to 25 C
ELECTRICAL: HPS (High Pressure Sodium): (70 to 1000W) MH (Metal Halide): (175 to 1000W) Voltages: 120, 208, 240, 277 or 480
HOUSING: Die cast aluminum housings and covers for excellent strength, light weight and corrosion resistance. Hinged door swings down for easy relamping and maintenance
REFLECTORS: Computer designed for optimal light distribution and efficiency
LENS: Tempered glass lens resists thermal shock Fully sealed and mechanically retained
MOUNTING: Fully pivoting steel yoke
Flood lights for use in hazardous rated locations. This fixture has a die cast housing and cover as well as a fully pivoting steel yoke.
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201272
www.ldpi-inc.com
H.I.D. FL SERIESH.I.D. FL SERIESF L O O D L I G H T S
Series:FD: Class 1, Div. 2, Groups A, B, C, D floodlight
0: Standard Fixture (HPS)
Lamp TypeS: High Pressure SodiumH: Metal Halide
Ballast CircuitP: ReactorH: High ReactanceC: Constant Wattage Autotransformer
Mounting Styley: yoke (trunnion)
UNIPAK® OptionsD: Unipak with diffuse coated lampE: Unipak with clear lampSee page 53.
Lamp Wattage10: 100W (HPS only)15: 150W (HPS only)17: 175W20: 200W25: 250W40: 400W00: 1000W Ballast Voltage
04: 120/208/277/240 VAC (wired 120)12: 120 VAC20: 208 VAC24: 240 VAC27: 277 VAC48: 480 VAC(Contact factory for other available voltages)
W: Wide Beam (8x6)N: Narrow beam (6x6) (400W max.)
0: Standard housing(400 W max.)L: Large housing(1000W)
HOUSINGSERIES LAMP STARTER WATT BALLAST VOLTAGE MOUNT BEAM UNIPAK OPTIONS
OF: Single fuseFF: Double fusePC: Photo controlPW: Pre-wired 3-1/2” cordBRZ: Bronze colorBLK: Black color(Standard color is gray.)
7 (179)
5-1/2(140)
21-1/8(537)
17-3/5(447)
19-1/2(495)
12-1/2(317)
23(584)
7/16 (11)
2(51) 1 (25)
25/32 (20)
2(51)
7(179)
5-1/2(140)
20-1/2(521)
21-7/16(545)
13(33)
23-71/6(595)
DIMENSIONS (Nominal)
NOTE:All floodlights for use with mogul base lamps.
OPTIONAL
ACCESSORIESCat. No. Description
75-8
75-V
Polycarbonate Vandal ShieldGlare ControlShield
YOKE MOUNT FLOODLIGHTS MOUNTING BRACKETS
Cat. No. Description
9901H
9902H
9920H
Steel Crossarm Mounting Bracket
Pole-Top Mounting Bracket
Universal WallMounting Bracket
INTEGRAL SLIPFITTER FLOODLIGHTS - MOUNTING BRACKETS
Cat. No. Description
9605
9605-G
9352
9333
Wall Mount Pipe Bracket (2") with Flange (Prime Coated)
Wall Mount Pipe Bracket (2") with Flange (Galvanized)
Two Arm Pole-Top Bracket ("Bullhorn")
Three Arm Pole-Top Bracket ("Bullhorn")
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
73
CFL SERIESCFL SERIESC O M PA C T F L U O R E S C E N T L I G H T S
CO
MP
AC
T F
LU
OR
ES
CE
NT
LIG
HT
S
Chemical PlantsOil Refineries
Offshore PlatformsAirplane Manufacturing
Waste ManagementSteel Mills
Power PlantsFood Processing Plants
Pulp and Paper MillsFoundry Operations
LISTINGS: Class I, Div. 2, Groups A, B, C, D Class II, Div. 1, Groups E, F, G (pendant mount only) UL 844 listed U.S. for hazardous locations UL 1598A listed U.S. for marine locations NEMA 4X IP66 ELECTRICAL: CFL (compact fluorescent) 13, 22, 26, 28 and 44 Watts Voltages: 120
HOUSING: Cast copper-free aluminum with powder coated finish Enclosed and gasketed
GUARD: Cast guard
REFLECTOR: Choice of dome or angle reflectors
GLOBES: Glass globes available as: clear, tempered, amber, blue, green and red
MOUNTING: Pendant, ceiling, wall or stanchion
Pendant Mount
Ceiling Mount
Wall Mount
Stanchion Mount
With Globe With Globe Guard & With Globe Guard & and Guard Dome Reflector Angle Reflector
The CFL Series is a cast copper-free aluminum fluorescent fixture with a powder coated finish rated for hazardous locations and adverse environments. The colored globe options make this a positive visual marker for areas such as safety eye wash locations, fire extinguishers, critical meters, controls and other safety needs.
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201274
www.ldpi-inc.com
CFL SERIESCFL SERIESC O M PA C T F L U O R E S C E N T L I G H T S
VFA: Pendant mountVFH: Fixture body for ceiling, wall or stanchion mountVFHA: Stanchion mountVFHB: Wall mount no boxVFHBF: Wall mount Std. boxVFHBFD: Wall mount deep boxVFHF: Ceiling mount Std. boxVFHFD: Ceiling mount deep box
1: 1/2” NPT hub*2: 3/4” NPT hub4: 1 1/4” NPT hub**
120: 120 VAC
G: Clear glassGP: Clear glass and guardTG: Tempered glassTGP: Tempered glass and guardACG: Amber glassBCG: Blue glassGCG: Green glassRCG: Red glassACGP: Amber glass and guardBCGP: Blue glass and guardGCGP: Green glass and guardRCGP: Red glass and guard
13: 13W (one 13W lamp)22: 22W (one 22W lamp)26: 26W (two 13 W lamps)28: 28W (one 28W lamp)44: 44W (two 22W lamps)
SERIES HUB WATTAGE GLOBEVOLTAGE REFLECTOR
RD: Dome reflectorRA: Angle reflector
D: Unipak® packaging (completely assembled in one carton with lamp)See Page 53U: UnlampedP: Lamped
Lamps available on request
PACKAGING
*VFH and VFHB - NO HUBS** Stanchion mount only
VFA
VGL22
VGU22P
VR22P VRA22P
VXB
VGL22
VGU22P
VR22P VRA22P
VXA4
VFH
VXF
ELECTRIC LIGHTING FIXTURES FOR INDUSTRIAL AND HAZARDOUS LOCATIONS
OPTIONAL
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 75
www.ldpi-inc.com
CFL SERIES OPTIONSCFL SERIES OPTIONSC O M PA C T F L U O R E S C E N T L I G H T S
REFLECTORS Cat. No. Description
VR22P
VRA22P
Standard domeFiberglass reinforced polyester
30 angle reflectorFiberglass reinforced polyester
GLASS GLOBES COLOR
Cat. No.Wattage, maximum Lamp size
Clear (heat resistant)RedGreenBlueAmber
150 Watt 200-300 WattVGT15 VGT22VGT15R VGT22RVGT15G VGT22GVGT15B VGT22BVGT15A VGT22A
MOUNTING Cat. No. Description
VXB
VXA4
Wall mount bracket arm
Stanchion mount bracket arm (conduit hub size 1 1/4”)
FIXTURE HANGERHUB COVERFOR VXF BOX
Cat. No. Conduit hub size
VHC1
VHC2
1/2”
3/4”
COVER Cat. No. Description
VHC1 Flat cover for VXF box
GASKET Cat. No. Description
GASK643 Gasket for hub covers, flat cover and bracket arms
STD. JUNCTION BOX (1 3/4” INSIDE DEPTH)FOR WALL OR CEILING MOUNT FIXTURES
Cat. No.4 Hubs 5 Hubs Conduit hub size
VXF10 VXFT10
VXF20 VXFT20
1/2”
3/4”
DEEP JUNCTION BOX (3” INSIDE DEPTH)FOR WALL OR CEILING MOUNT FIXTURES
Cat. No.4 Hubs 5 Hubs Conduit hub size
VXFD10 VXFTD10
VXFD20 VXFTD20
VXFD30 VFXDT30
1/2”
3/4”
1”
LAMPS Cat. No. Description
PLC-13
PLC-22
PLC-28
13W
22W
28W
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201276
www.ldpi-inc.com
CFL SERIES T-RATINGSCFL SERIES T-RATINGSC O M PA C T F L U O R E S C E N T L I G H T S
13 Watt 0ºC(32ºF) 40ºC(104ºF) 110ºC T3 T3
22 Watt -29ºC(-20ºF) 40ºC(104ºF) 110ºC T3 T3
26 Watt 0ºC(32ºF) 40ºC(104ºF) 110ºC T3 T3
28 Watt -29ºC(-20ºF) 40ºC(104ºF) 110ºC T3 T3
44 Watt -29ºC(-20ºF) 40ºC(104ºF) 110ºC T3 T3
FIXTURE WATTAGE
AMBIENT TEMPERATURE
Minimum Maximum
CLASS I, DIVISION 2 T-NUMBERSUPPLy WIRETEMPERATURE Globe, Guard Globe, Guard & Reflector
Temperature Information
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
77
LISTINGS: ETL listed for U.S. and Canada Class I Division 2 Groups A,B,C,D T3C (160 degree C) operating code Class II Division 2 Groups F & G T3C (160 degree C) operating code Conforms to UL 1598 and UL 844 Certified to CSA 22.2 No. 137 and 250 FEATURES: Slim 2 - 1/4” thick 1 piece housing made from 20 ga. CRS & powder coated black paint. Front Access door frame.
LENS: 3/16” clear tempered glass with stripes.
ELECTRICAL: Available in 32 or 59 watt with T8 lamps Voltages: 120-277
OPTIONS: ALL OPTIONS ORDERED SEPARATELy - see pages 79-80 Stationary mount kit #3564 Pivot hinge mount kit #3563 Swivel mount kit #4828 (For carts and 4 Ft. fixtures ONLY) Clear glass lens (Consult factory for cord and plug options)
The Inspection Series is a must for any surface finish inspection area! Fixture is constructed from a cold rolled steel one piece housing, with a 93% reflectance specular polished reflector. The lens design creates a well defined lamp image using light and dark contrasts that cause defects in the paint to show for ease of detection and repair. The series is available in 4 or 8’ lengths. Optional stands are available to suit any inspection area needs. Horizontal and Vertical cart options (see Portable Lighting Section) also available. Lamps included.
Series Lamp Lamp Qty Hub Order # Voltage
39042LINS T8 32W 2 1/2” NPT 39042LINS - 3613 120-277 Volts 50/60HZ
39082LINS T8 59W 2 1/2”NPT 39082LINS - 3281 120-277 Volts 50/60HZ
LAMPS INCLUDED(All Options Ordered Separately)
Paint InspectionPlastic InspectionDefect Detection
INSPECTIONINSPECTIONL I G H T I N G S E R I E S
INS
PE
CT
ION
LIG
HT
ING
Vertical 3 fixture cartSee page: 83-84
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201278
www.ldpi-inc.com
DIMENSIONS
14 1/16”98 3/16”
14 1/16”1 1/8”
70”
Ø 3/8” -16 THREAD4 PLCS 2 5/8”
20 1/2”
2 1/4”GROUND SCREWBALLAST SCREWS
DOORH NGE
HUB LOCATION
DOOR ACCESSSCREWS5 PLCS
4 Ft. 39042LINS
8 Ft. 39082LINS
INSPECTIONINSPECTIONL I G H T I N G S E R I E S
DEFECT DETECTION LENS
2 1/4”GLASS FRAME ASSY.
51 27/32”*
20 1/2”
1”
1/2” NPT CONDUIT HUB2 1/16”
1 1/8”47 3/4”
(BETWEEN MOUNT NG HOLES)
FASTENER (TYP)2 1/16”
2 1/4”MOUNTING HOLE FOR 3/8-16 UNC
DOOR ACCESSSCREWS3 PLCS
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 79
www.ldpi-inc.com
INSPECTION SERIES MOUNTING
15
10
4 Foot Fixture Rotation 8 Foot Fixture Rotation
P/N 3563 Pivot Hinge Mount Kit 4 Ft. and 8 Ft.Fluorescent Inspection Lighting
Pivot mount or stationary mounting brackets allow aiming of fixtures for optimal performance.
NOTE: Not available for INS2 fixtures.
P/N 3564 Stationary Mount Kit4 Ft. and 8 Ft.
Fluorescent Inspection Lighting
FIXT
URE
Front of fixture faces direction of arrow
This SQ. Hole to back of fixture
2” SQ. Tube
Top View Side View Fixture Front
INSPECTION CART SWIVEL MOUNTP/N 4828 Swivel Mount Kit(For mounting fixtures on a 2” square tube frame. For use on 4 Ft. fixtures only.)
INSPECTION MOUNTSINSPECTION MOUNTSF O R L D P I , I n c . I N S P E C T I O N F I X T U R E S
Tunnel provides visual angles from all sides and can be designed with combinations of 4 Ft. and 8 Ft. fixtures to fit product and application requirements.Fixtures mounted 26 1/2" on center. INS2 fixtures mounted 18" on center.
INS2 with 8 Ft. fixture top horizontal mount4 Ft. fixture top horizontal mount 8 Ft. fixture top horizontal mount
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201280
www.ldpi-inc.com
Pivot mount or stationary mounting brackets allow aiming of fixtures for optimal performance.NOTE: Not available for INS2 fixtures.
*Top horizontal strut: bolted or welded to existing ceiling structure.
*Vertical Foot: bolted or welded to existing floor structure (Typical both sides)
STANDARD INSPECTION TUNNEL
LDPI’s Inspection Tunnel provides visual angles from all sides and can be designed with combinations of 4 Ft. and 8 Ft. fixtures to fit product and application requirements.
1. Unistrut is 1 5/8” square Minimum 16 gauge Choice of galvanized or painted green
2. All pieces are bolt-together
3. Strut pieces supplied cut to length unless specified otherwise.
4. Tunnel will need to be bolted or welded to existing structure*
5. Fixtures mounted 26 1/2" on center
Standard Inspection Tunnel Standard Inspection Tunnel with pivot mounts
INSPECTION TUNNELINSPECTION TUNNELF O R L D P I , I n c . I N S P E C T I O N F I X T U R E S
NOTE: Recommended ambient light level of 20-25 foot-candles outside the tunnel.
INS2 with 8 Ft. fixture top horizontal mount4 Ft. fixture top horizontal mount 8 Ft. fixture top horizontal mount
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
81
INS2 SERIESINS2 SERIESI N S P E C T I O N L I G H T I N G
INS
PE
CT
ION
LIG
HT
ING
LISTINGS: UL listed 1598 U.S. and Canada
HOUSING/FINISH: Black powder coat housing and end caps 6063 T6 Extruded aluminum Custom powder coat colors or anodized finishes available upon request.
REFLECTOR: Symmetrical 91% reflectance
DIFFUSER: Extruded acrylic, UV stabilized Proprietary surface finish for inspection and defect detection applications.
END CAPS: Die formed aluminum
HARDWARE: Zinc plated steel
MOUNTING: Integrated channel on back side of housing allows for surface, pendant, cable, or any other type of desired mounting. (Mounting hardware NOT included)
ORIENTATION: Horizontal, vertical, angular, lamp up, or lamp down
HUB SIZES: 1/2” on one end standard
ELECTRICAL: Available in 17, 32 and 59 watt with T8 lamps Voltages: 120, 277, 120/277 and 347
BALLAST TyPE: Instant start standard
LAMP HOLDER(S): Tombstone style, twist lock
OPTIONS: ALL OPTIONS ORDERED SEPARATELy Cord and plug (specify voltage) • MOUNTING KITS - ordered separately - see page 98
INS2 fixture is specifically designed for inspection and defect detection applications. The proprietary refractor on the INS2 fixture creates distinct luminance edges on painted surfaces which significantly increases the visibility of topographic defects such as dirt in paint, runs, sags, craters, etc. This fixture is available in multiple lengths and can be installed as a stand-alone unit or in a continuous row up to 16’ long. It features a black powder coated housing and end caps with an integrated channel on the backside of the housing to allow for surface, pendant, cable or various other mounting options. Lamps included.
Paint InspectionPlastic InspectionDefect Detection
PATENT PENDING
2 Ft. fixture with optional 6 Ft. cord and plug Diffuser Detail
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201282
www.ldpi-inc.com
INS2 SERIESINS2 SERIESI N S P E C T I O N L I G H T I N G
4 11/16"
5/16"-18 CARRIAGE SCREW MOUNTING TRACK
25 1/8"26 5/16"
5 17/32"
2 Ft. Fixture
5 17/32"
49 1/8"50 5/16"
4 Ft. Fixture
5 17/32"
97 1/8"98 5/16"
8 Ft. Fixture
MOUNTING CHANNEL
END CAP
OPEN END
CORD END
NOTE: UNV1 (Universal voltage) is standard on fixtures without cords.When ordering fixture with a cord (CP6) specify the voltage accordingly. Standard plug is a NEMA rated straight blade.
INS2 T8: 17W (2 Ft.) 32W (4 Ft.) 59W (8 Ft.)
1L: 1 Lamp2L: 2 Lamp3L: 3 Lamp4L: 4 Lamp
2: 2 Ft.4: 4 Ft.8: 8 Ft.12: 12 Ft.16: 16 Ft.
120: 120V277: 277VUNV1: 120/277V347: 347V
PB: Powder Coat BlackAB: Anodized Black
C6: 6 Ft. Cord no plugCP6: 6 Ft. Cord with plug
CORD/PLUGSERIES LAMP TyPE LAMP QTy LENGTH (Ft.) VOLTAGE FINISH
Available Lamp ConfigurationsNominal Fixture Length QTy of Lamps Nominal Lamp Length
2 Ft. 1 24 in.4 Ft. 1 48 in.8 Ft. 1 96 in.8 Ft. 2 48 in.
12 Ft. 3 48 in.16 Ft. 2 96 in.16 Ft. 4 48 in.
INS2 Inspection tunnel.
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
83
4 Ft. Single Fixture Cart
FIXTURE ETL listed. U.S. and CanadaLISTINGS: INS: Non-Hazardous H: Class I and II Division 2 I: UL 1598 ONLy
ELECTRICAL: Available in 32 watt with T8 lamps Voltage: 120 volts or 277 volts Hazardous location carts 120 volts only
OPTIONS: CART OPTIONS Shelf trays: 20 1/2” W x 8” D x 3” H (Qty 2) P/N 7638 20 FT. cord reel for non-hazardous carts P/N 7639
FIXTURE OPTIONS INS: Inspection with tempered, striped lens (lamps included) H: Class I & II Div. 2 Industrial with tempered lens (lamps included) I: Task/Open industrial with polycarbonate lens (lamps included)
REPLACEMENT PARTS Polycarbonate replacement Lens P/N 7756 F32-T-8 Lamp, 5000K - (Recommended)
2 WHEEL VERTICAL CART: P/N 43468” semi-pneumatic ball bearing wheels20’ power cord with a 3 prong 120 Volt 15 amp plugor 277 Volt 15 amp plug available. Must specify.NEMA rated power cord plugs other than specified can be provided.
The single fixture light cart is designed to provide portable lighting solutions for applications ranging from inspection to laboratory and general industrial task lighting. Light fixture options allow you to customize your cart to fit your work application requirements. Some assembly required. Lamps included.
Optional Shelf Tray (2 per cart)
Cart Frame
20 Ft.Power Cord
8” Semi-PneumaticBall Bearing Wheels
Task AreasGeneral Industrial
Portable Inspection Areas
4346: LIGHT CART20’ power cord(Specify voltage)
INS: Inspection (Tempered, striped glass)H: Hazardous location (Class I and II, Div. 2)I: Open industrial (UL 1598)
SERIES FIXTURE VOLTAGE
120: 120V standard277: 277V optional*
*277 voltage not available for hazardous locations
CART SERIESCART SERIESTA S K / I N S P E C T I O N / H A Z A R D O U S
TAS
K /
IN
SP
EC
TIO
N /
HA
ZA
RD
OU
SFIXTURE ONLY
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012
SPEC
IFIC
ATIO
NS
84
The 4 Ft. 2 and 3 fixture light carts are designed to provide portable lighting solutions for applications ranging from inspection to laboratory and general industrial task lighting. A 4 Ft. single fixture horizontal mount cart is also available for all fixture types. Fixtures are attached with swivel mounting brackets allowing for directional aiming of the light (Hazardous location fixtures are stationary mounted). ASSEMBLY REQUIRED.Black finish with standard 10” pneumatic tires. (2) swivel (2) non-swivel. Standard 25’ power cord with a 3 prong 120 Volt 15 amp plug.Optional 277 Volt 15 amp plug available. Must specify.
Shown with optional tool tray3 Fixture Inspection Cart
Standard 10” Pneumatic Tires
Vertical Mount Horizontal Mount 2 Fixture Only
General IndustrialPortable Inspection Areas
NOTES:P/N 3668H and 3669H are Class I Div. 2 hazardous location carts.These carts are assembled with a stationary fixture mounting bracket.
P/N 3669 and 3669H 3 Fixture carts: vertical mounting position ONLY.
P/N 3668H: Must specify vertical or horizontal mounting. Add a V or H to the end of the part number.
3668: 2 Fix. Cart3668H: 2 Fix. Haz. Loc. Cart3669: 3 Fix. Cart3669H:3 Fix. Haz. Loc. Cart4520: 1-4 Ft. Horizontal Cart
INS: Inspection (Tempered, striped glass)H: Hazardous Location(Class I and II, Div. 2)I: Open Industrial(UL 1598)
P: 10” TiresPneumatic (Std)
SERIES FIXTUREWHEELS
120: 120V Standard277: 277V optional*
VOLTAGE
*277 Voltage not available for hazardous locations
CART SERIESCART SERIESTA S K / I N S P E C T I O N / H A Z A R D O U S
FIXTURE ETL listed. U.S. and CanadaLISTINGS: INS: Inspection H: Class I and II Division 2 I: UL 1598 ONLy
ELECTRICAL: Voltage: 120 volts or 277 volts Amperage: 15 amps standard Hazardous location carts 120 volts only
OPTIONS: Vertical or horizontal fixture mount (1 or 2 fixture carts only) Outlet box with 1 duplex outlet available for non-hazardous 120 volt carts P/N 7641 Tool tray with adjustable shelves P/N 7640 NEMA rated power cord plug, other than specified, can be provided.
FIXTURE OPTIONS: INS: Inspection with tempered, striped lens (lamps included) (vertical mount recommended) H: Class I & II Div. 2 industrial (lamps included) I: Task/open industrial (lamps included)
REPLACEMENT PARTS Polycarbonate lens F32-T-8 lamp, 5000K - (recommended)
TAS
K /
IN
SP
EC
TIO
N /
HA
ZA
RD
OU
SOptional Outlet Box
Standard 10”Pneumatic Tires
25 Ft. MainPower Cord
Standard 10” Non-Swivel Pneumatic Tires
Optional Tool Tray With AdjustableShelves
4520: 1-4Ft.Horizontal Fixture
FIXTURE ONLY
3 Fixture CartVertical Mount ONLy
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com
DATE: PROJECT MGR:
JOB:
PN:
APPL
ICAT
IONS
SPEC
IFIC
ATIO
NS
85
Lighting for Explosive Environments - The 380 Portable Light Cart is manufactured in accordance with applicable NFPA standards. For use in hazardous environments and laboratory applications. Portable lighting solutions for hazardous atmospheres. Light can be directed where you need it most. Fixture(s) sold separately. For light fixture specifications - see page 35
FIXTURELISTINGS: UL listed 844 U.S. and Canada for hazardous locations UL listed 1598 U.S. and Canada for wet locations UL listed 1598A U.S. and Canada for marine locations
FEATURES: For either 2, 3 or 4-lamp 4 foot fixture 5” non-sparking casters (1 pair fixed, 1 pair swivel) 360 non-continuous adjustable fixture rotation Lamps, polycarbonate shield and stainless steel guard: ALL INCLUDED
ELECTRICAL: Available in 28, 32, 34, 44, 54 and 60 watt with T5, T5HO, T8 and T8HO lamps Voltages: 120 50 Ft. of S.O. electric cable suitable for rough duty use Explosion proof switch Explosion proof plug - 120 volt (P/N 3825)
HOUSING: Frame constructed of corrosion resistant aluminum
REFLECTOR: One piece aluminum reflector
LENS: Clear tempered glass tubes, polycarbonate shield.
MOUNTING: Fixture mounted to 360 (non-continuous) adjustable rotating brackets OPTIONS: 2 lamp model (P/N 4372-2) 3 lamp model (P/N 4372-3) 4 lamp model (P/N 4372-4)
380 Series Cart 4 Lamp
380 Cart 2 Lamp
Hazardous LocationsPaint Inspection AreasLaboratory ApplicationsCorrosive Environments
Aircraft HangarsMaintenance Pits
XP CART SERIESXP CART SERIESE X P L O S I O N P R O O F L I G H T C A RT
EX
PL
OS
ION
PR
OO
F L
IGH
T C
AR
T
FIXTURE ONLY
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201286
www.ldpi-inc.com
DIMENSIONS
B
C
A
B
4 LAMP 2 LAMP
Note: LDPI®
recommends consulting local authorities for approval of your application prior to purchase.
A — 58” B — 24” C — 24 3/4” D — 27 5/8” E — 29 9/16”
2, 3 and 4 Lamp Cart
4 Ft. Lamp WattageT5 28WT5 H.O. 54WT8 32WT8 H.O. 44W
LAMP WATTAGESNOTE:*5000K lamp standard for T5HO and T8 lamps**4100K lamp standard for T8HO and T5 lampsAll T5, T5HO & T8 are universal voltage3 lamp fixtures not available in T8HO
380
4: 4 Ft.120: 120 Volts
234
4372-2: (2 Lamp cart)4372-3: (3 Lamp cart)4372-4: (4 Lamp cart)
SERIES LAMP TyPE LAMP QTy VOLTAGELENGTHCART
HB: 93% Reflective specular reflector insert
OPTIONS
T5** T5HO*
T8*
T8HO**
XP CART SERIESXP CART SERIESE X P L O S I O N P R O O F L I G H T C A RT
D E
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 87
www.ldpi-inc.com
MOUNTINGMOUNTINGF O R L D P I , I N C . F I X T U R E S
222 Series
7 3/4"
3 1/2"
5 1/2"222-T5HO-2L-4-UNV1-NA
NARROW ANGLE REFLECTOR
5 1/2"
5 11/16"
1 13/16"
222-T5HO-2L-4-UNV1STANDARD BALLAST COVER
10"
5 1/2"
3 1/2"
222-T8-3L-4-UNV1-WAWIDE ANGLE REFLECTOR
Ø7/8" ELECTRICALKNOCK OUTBOTH ENDS
Ø7/8" ELECTRICALKNOCK OUT
222 T5HO 2L 4 UNV1LIGHT FIXTURE
(T5HO: 46" )(T8/T8HO/T12: 48")
TOOL LESSACCESS FASTENER
95 7/8"
ACCESS FASTENERS
Ø7/8" ELECTRICALKNOCK OUTBOTH ENDS
222 T8 2L 8 UNV1 WA96W T8 SLIMLINE LIGHT FIXTURE
Ø7/8" ELECTRICALKNOCK OUTBOTH ENDS
(T8/T8HO/T12 95 7/8" )(T5HO 91 7/8")
ACCESS FASTENERS
Ø7/8" ELECTRICALKNOCK OUTBOTH ENDS
222 T8 6L 8 UNV1 WALIGHT FIXTURE
Ø7/8" ELECTRICALKNOCK OUTBOTH ENDS
HANGING BRACKETQTY (2)
5FT NO. 2LOOP HANGING CABLE
QTY (2)
CM: Cable Mount Hangar Kit
HANGING BRACKETQTY (2)
24" JACKCHAINQTY (2)
CH: Chain Mount Hangar Kit
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201288
www.ldpi-inc.com
MOUNTINGMOUNTINGF O R L D P I , I N C . F I X T U R E S
229H Series
48 1/4” nominal
14 1/2”
Wire Whip Not Shown
Ballast plate is hinged for easy access
4”
24” Chain Piece (Qty. 2)
Chain HangerBracket (Qty. 2)
229H Light Fixture
Part Number: 3218 Chain Hang Kit
MOUNTING - ORDERED SEPARATELy
DIMENSIONS (Nominal)
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 89
www.ldpi-inc.com
240 Series (4 Ft.)
Adjustable Surface Mounting Bracket KitPart Number: (6856 galvanized) and (6856SS stainless steel)Bracket attachment point for optional mounting methods
Cable Hang KitPart Number: (6875 zinc coated)and (6875SS stainless steel)QTy 2 cables with toggle endsand QTy 2 self locking gripples
52 1/4” between chains
Pendant Style Mounting NOTE: Conduit provided by others
Fixture suspended with 1/2” electrical conduit using top hubs on fixture at both ends.
45” between conduit
THERE ARE A NUMBER OF MOUNTING METHODS THAT ARE NOT SHOWN.
MOUNTINGMOUNTINGF O R L D P I , I N C . F I X T U R E S
Chain Hang KitPart Number: (7979)
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201290
www.ldpi-inc.com
240 8 ft. Series
Adjustable Surface Mounting Bracket KitPart Number: (9349 galvanized) and (9349SS stainless steel)Bracket attachment point for optional mounting methods
Cable Hang KitPart Number: (6875 zinc coated)and (6875SS stainless steel)QTy 2 cables with toggle endsand QTy 2 self locking gripples
102” between cables
Pendant Style Mounting NOTE: Conduit provided by others
Fixture suspended with 1/2” electrical conduit using top hubs on fixture at both ends.
94 7/8” between conduit
THERE ARE A NUMBER OF MOUNTING METHODS THAT ARE NOT SHOWN.
Chain Hang KitPart Number: (9350)
NOTE: Mounting kits shown on shorter 4 Ft. fixture for clarity
8 Ft. 6 lamp shown with Adjustable Surface Mounting Bracket kit
MOUNTINGMOUNTINGF O R L D P I , I N C . F I X T U R E S
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 91
www.ldpi-inc.com
Item Description Qty.1. 1/2” x 3/4” Gasket 12’2. Light Clip 43. Glass Clip 24. Clear Tempered Glass 1 3/16” x 15” x 53” *Not included in kit. Ordered separately as P/N 17065. 1 1/2” x 1 1/2” Corner Bracket 46. Frame (15 3/4” Long) 27. Frame (53 1/2” Long) 28. 1/8” Pop Rivet 89. Nut Hex 1/4 - 20 Zinc Coated HHCS 1/4 - 20 Zinc Coated 10 Installation Sketch 1
98
7
6
5
4
32
1
*Not Included in Kit
Not Included in Kit
Not Included in Kit
Inner Surface of Panel
12 1/2” x 50 1/4” Hole
See DetailA-1
Panel
Frame
13
4
Detail A-1
Installation Detail
241 Series
Part Number: 4692 Installation Kit
MOUNTINGMOUNTINGF O R L D P I , I N C . F I X T U R E S
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201292
www.ldpi-inc.com
260/261 Series
OPTIONAL:PANEL ST FFENER
KIT # 1704(FITS 18 GA. PANELS ONLY)
PA NT SPRAyBOOTH PANEL 390260
FIXTURE
19 5/8” X 51 1/4”
HOLE SIZE
BOOTH NTERIORFOAM GASKETING
NSTALLATION FASTENER1/4 - 20 UNC X 3/4”
FRAME FASTENER
GLASSNTERLOCK
SWITCH
PANEL ST FFENER
1/4 - 20 UNC U-NUTHUB
NOTE: DUAL ACCESS MODEL # 390260 SHOWN.MODEL 390261 IS A REAR-ACCESS ONLy. (DIMENSIONS ARE THE SAME.)
A B
NEMA 1SWITCH
yELLOW
INTERLOCK SWITCH TO BE WIRED IN SUCH A WAy THAT IT DISABLES PAINT SPRAy EQUIPMENT WHEN LIGHT IS ACCESSED FROM INSIDE OF THE PAINT SPRAY BOOTH.
yELLOW
Part Number: 1704 Panel Stiffener and Interlock Switch
51 1/4”7 5/8” 7 5/8”12” 12” 12”
12”19 5/8”
3 13/16”
3 13/16”
3/8” TYP.
CUT LIGHT HOLE 19 5/8” X 51 1/4”
5/16” Dia. 12 Holes
IMPORTANT:Normally open magnetic switches are intended to be used to trigger a relay (furnished by others) which disables the paint system. Because of the small capacity of the switch, a solid state relay is recommended. It may be desired by others to utilize a separate power supply to segregate the relay (furnished by others) from lighting power supply. The magnetic switch is rated for 10 watts (resistive) at a maximum of 300 VAC.
The magnetic switch is NOT designed to directly control light operation.
CAUTION: Overloading the switch circuits will cause failure.LDPI® recommends having a certified electrician/engineer reviewcircuit loads to insure that overloading of switch does not occur.
MOUNTINGMOUNTINGF O R L D P I , I N C . F I X T U R E S
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 93
www.ldpi-inc.com
280/281 Series
OPTIONAL: Panel Stiffener Kit # 1728Fits 18 Ga. Panels ONLY
Paint Spray Booth Panel
390280Fixture
19 5/8” X 100 5/8”
HOLE SIZE
BOOTH INTERIORFOAM GASKET NG
INSTALLATION FASTENER1/4 - 20 UNC X 3/4”
FRAME FASTENER
GLASSMAGNET
NTERLOCK SWITCH
PANEL ST FFENER1/4 - 20 UNC U-NUT
HUB
MOUNTING DETAIL SHOWING FIXTURE IN PANEL.
IMPORTANT:Normally open magnetic switches are intended to be used to trigger a relay (furnished by others) which disables the paint system. Because of the small capacity of the switch, a solid state relay is recommended. It may be desired by others to utilize a separate power supply to segregate the relay (furnished by others) from lighting power supply. The magnetic switch is rated for 10 watts (resistive) at a maximum of 300 VAC.
The magnetic switch is NOT designed to directly control light operation.
CAUTION: Overloading the switch circuits will cause failure. LDPI® recommends having a certified electrician/engineer review circuit loads to insure that overloading of switch does not occur.
A B
NEMA 1SWITCH
yELLOW
INTERLOCK SWITCH TO BE WIRED IN SUCH A WAy THAT IT DISABLES PAINT SPRAy EQUIPMENT WHEN LIGHT IS ACCESSED FROM INSIDE OF THE PAINT SPRAY BOOTH.
yELLOW
Part Number: 1728 Panel Stiffenerand Interlock Switch
100 5/8”13 3/8” 12” 12” 12”
3 13/16”
3 13/16”
3/8” TYP.
HOLE DETAIL 5/16” Dia. 12 Holes
7 5/8”7 5/8”
12”
19 5/
8”
12” 12” 12”
MOUNTINGMOUNTINGF O R L D P I , I N C . F I X T U R E S
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201294
www.ldpi-inc.com
11 1/8"
22 1/2"
15 13/16
"15 13/16"
77 5/16"
FEATURESPart Number: 4714To reduce shadowing, corner or hip lighting is ideal.Corner light mounting option is available for the 390440J-3546 Slim Light ONLY. (Page 21).FIXTURE SOLD SEPARATELYShipping weight: 14#.Paint Booth Corner or Hip
Mount for fluorescent lighting NOTE: All wiring must be performed by a certified electrician and in accordance with all national and local electrical codes and regulations.
Kit (delivered unassembled) Includes:• Self tapping screws to mount panel to booth• Bolts/Nuts to mount fixture to panel.• Wire whip pre-wired to fixture.• (4) feet of 1/2” Liquid-Tite Flexible conduit• 90 Flex connector to exit booth• Straight flex connector to secure flex to fixture• (1) Tube of caulk to seal around panel and fixture perimeter
NOTE:Mounting requires drilling 7/8” hole in booth wall or ceiling to route flex conduit out of booth.
Horizontal or Vertical Mounting Corner/Hip Light KitThe following is an acceptable method of installing panel mounted fixtures into the corner of a paint spray booth.
DESCRIPTION
SPECIFICATIONS
KIT: 18 gauge galvanized panel
REQUIREMENTS: For use with the 390440J-3546 Fixture only. (Fixture Sold Separately)
Panel construction must meet the requirements of NFPA 33 Chapter 3, “Construction and Design of Spray Areas, Spray Rooms, and Spray Booths.”
Fixture installation wiring to meet the requirements of NFPA 33 Chapter 4, “Electrical and Other Sources of Ignition.”
OPTIONS: Powder Coat Finish
Corner or Hip Mount Kit (PN 4714) for use with 390440J-3546 Slim Light fixture ONLY.Can be installed vertically in a corner, or horizontally in the hip of the booth.Includes all components required to install kit and route wiring conductors out of booth.
CORNER/HIP MOUNTCORNER/HIP MOUNTF O R 4 4 0 S L I M L I G H T F I X T U R E
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 95
www.ldpi-inc.com
MOUNTING TEMPLATE
1/4 - 20 UNC X 1” FASTENERSP/N 1705
1/2 NPTCONDUIT HUB
PA NT SPRAy BOOTH PANEL
EXTERIOR BOOTH PANEL
FOAM GASKET NG
NSTALLATIONFASTENER
1/4-20 UNC X 3/4”
GLASS ASSEMBLY FRAME FASTENER
3/8” ( NSTALLED)
GLASS
2-1/4” + 1/16”INSTALLED
INTERIOR BOOTH PANEL
FIXTURE FLANGE
1/2 NPTCONDUIT HUBT5HO FIXTURE ONLY
Slim Light Series Mounting Hole Detail
38 1/4”
16” 16”
HOLE DETAIL (3 FT. FIXTURES)
3 1/8”
E5/16” TYP
38 7/8”
1/2” TYP
1 7/8”
1 7/8”
5/16” DIA. 10 Holes
F
300 S
ERIE
S
Slim Light Series
HOLE DETAIL DIMENSIONSTYPE E F2 LAMP FIXTURE 10 3/4” 7”4 LAMP FIXTURE 15 3/4” 12”6 LAMP FIXTURE 20 3/4” 17”
50 1/4”
16” 16”
HOLE DETA L (4 FT. FIXTURES)
1 1/8”
E5/16” TYP
50 7/8”
1/2” TYP
1 7/8”
1 7/8”
5/16” DIA. 12 Holes F
16”
400 S
ERIE
S
MOUNTINGMOUNTINGF O R L D P I , I N C . F I X T U R E S
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201296
www.ldpi-inc.com
400 Rear Access Series
MOUNT NG CUT-OUT
1/4-20 UNC X 3/4”FASTENERSP/N 1705
PA NT SPRAyBOOTH PANEL
1/2 NPT CONDUIT HUBON BOTTOM. (NOT SHOWN)
GASKET MATERIAL
BOOTH PANEL
CAULK CONSISTENTLy AROUND THE ENTIRE PERIMETER OF THE
FIXTURE AFTER MOUNTING.
INSTALLATION FASTENER1/4-20 UNC X 3/4”
FRONT OF FIXTURE
BOOTH EXTERIOR
3 1/2” + 1/16”INSTALLED
50 1/4”
16” 16”
HOLE DETA L (4 FT. FIXTURES)
1 1/8”
E5/16” TYP
50 7/8”
1/2” TYP
1 7/8”
1 7/8”
Ø 5/16” DIA. 12 Holes
F
16”
MOUNTING HOLE DIMENSIONS
HOLE DETAIL (2 FT. 390231)
Ø 5/16” DIA. 10 Holes
E10 3/4”
F
26 1/4”
1 7/8”
1/2” TYP12”12”
26 7/8”1 7/16”
5/16”TyP
MODEL A B C D E F390231 10” 12 1/2” 26” 28 3/8” 11 3/4” 8” 390421 10” 12 1/2” 50” 52 3/8” 10 3/4” 7” 390441 15” 17 1/2” 50” 52 3/8” 15 3/4” 12” 390461 20” 22 1/2” 50” 52 3/8” 20 3/4” 17”
FIXTUREDIMENSIONS
MOUNTINGDIMENSIONS
MOUNTINGMOUNTINGF O R L D P I , I N C . F I X T U R E S
CD
A B
3 1/2”
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 97
www.ldpi-inc.com
MOUNTINGMOUNTINGF O R L D P I , I N C . F I X T U R E S
INSPECTION SERIES MOUNTING
15
10
4 Foot Fixture Rotation 8 Foot Fixture Rotation
P/N 3563 Pivot Hinge Mount Kit 4 Ft. and 8 Ft.Fluorescent Inspection Lighting
Pivot mount or stationary mounting brackets allow aiming of fixtures for optimal performance.
NOTE: Not available for INS2 fixtures.
P/N 3564 Stationary Mount Kit4 Ft. and 8 Ft.
Fluorescent Inspection Lighting
FIXT
URE
Front of fixture faces direction of arrow
This SQ. Hole to back of fixture
2” SQ. Tube
Top View Side View Fixture Front
INSPECTION CART SWIVEL MOUNTP/N 4828 Swivel Mount Kit(For mounting fixtures on a 2” square tube frame. For use on 4 Ft. fixtures only.)
Tunnel provides visual angles from all sides and can be designed with combinations of 4 Ft. and 8 Ft. fixtures to fit product and application requirements.Fixtures mounted 26 1/2" on center. INS2 fixtures mounted 18" on center.
INS2 with 8 Ft. fixture top horizontal mount4 Ft. fixture top horizontal mount 8 Ft. fixture top horizontal mount
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 201298
www.ldpi-inc.com
MOUNTINGMOUNTINGF O R L D P I , I N C . F I X T U R E S
INS2 Series
CEILING / WALL MOUNT(OPTIONAL) KIT# 8171
DIRECT MOUNT(STANDARD)
1/2" WASHER TO BE USED WHEN MOUNTING TO MATERIAL 3/32" THICK OR LESS
CABLE / CHAIN MOUNT(OPTIONAL) KIT# 8170
CABLE / CHAIN MOUNT EYELET
5/16" -18 LOCKING NUT (STANDARD)5/16" FLAT WASHER (STANDARD)
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 99
www.ldpi-inc.com
222 GENERAL INDUSTRIAL SERIES PAGE: CALL
229H GENERAL INDUSTRIAL SERIES PAGE: 100
236 HIGH BAy SERIES PAGE: CALL
240 VAPOR/DUST PROOF SERIES PAGE: 101-102
240 8 FT. VAPOR/DUST PROOF SERIES PAGE: CALL
241 VAPOR/DUST PROOF SERIES PAGE: 103
260/261 VAPOR/DUST PROOF SERIES PAGE: 103
280/281 VAPOR/DUST PROOF SERIES PAGE: 104
300/400/500 SLIM LIGHT VAPOR/DUST PROOF SERIES PAGE: 104-106
400 REAR ACCESS VAPOR/DUST PROOF SERIES PAGE: CALL
440T T-5 TROFFER SERIES PAGE: 107
440 2x4 T-8 TROFFER SERIES PAGE: CALL
376 WET/DAMP SERIES PAGE: 107-110
379 WET/DAMP SERIES PAGE: 110-112
379i WET/DAMP SERIES PAGE: CALL
380 EXPLOSION PROOF SERIES PAGE: 113-114
381 VAPOR PROOF SERIES (INCANDESCENT) PAGE: CALL
383 EXPLOSION PROOF SERIES (INCANDESCENT) PAGE: CALL
384 MARINE SERIES PAGE: CALL
387 VAPOR PROOF SERIES (CFL & HID) PAGE: 115-121
INDUCTION SERIES PAGE: CALL
H.I.D. H/H2 AND XP/XP2 SERIES PAGE: CALL
H.I.D. FL FLOOD SERIES PAGE: CALL
CFL SERIES PAGE: CALL
INSPECTION SERIES PAGE: 121
INS2 SERIES PAGE: CALL
PORTABLE LIGHTING PAGE: CALL
LDPI, INC. PHOTOMETRICS DIRECTORy
For all represented photometrics in .ies and .pdf format, please visit our website at: www.ldpi-inc.comClick on the technical tab and select photometrics.Photometric viewer required for .ies files.
Photometric calculations run based on the provided photometrics are the sole responsibility of the user.These photometrics were produced in accordance with the IES in an Independent Laboratory. Caution should be used when inputting data as many outside influences may affect the results such as, but not limited to, reflectance of materials within the space, obstructions within the space, and variances in electrical components. LDPI, Inc. makes no warranty for the use of these photometrics.
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012100
www.ldpi-inc.com
229H SERIES MODEL#: 390229H-3546
WHITE INTERIOR AND NO LENSFOUR PHILIPS 32 WATT T8 LAMPSF32T8/TL841. Lumen rating = 2950 LMS.Total Luminaire Efficiency 83.6 %Spacing(0-180) 1.28(90-270) 1.48
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 1.00 1.00 1.00 1.00 .97 .97 .97 .97 .93 .93 .93 .89 .89 .89 .85 .85 .85 .841 .90 .86 .82 .78 .88 .84 .80 .77 .80 .77 .75 .77 .75 .72 .74 .72 .70 .682 .81 .74 .68 .62 .79 .72 .66 .62 .69 .64 .60 .66 .62 .59 .64 .60 57 .563 .74 .64 .57 .51 .71 .63 .56 .50 .60 .54 .49 .58 .53 .49 .56 .51 48 .464 .67 .56 .48 .42 .65 .55 .48 .42 .53 .47 .42 .51 .45 .41 .49 .44 40 .385 .61 .50 .42 .36 .59 .49 .41 .36 .47 .40 .35 .45 .40 .35 .44 .39 35 .336 .56 .45 .37 .31 .55 .44 .36 .31 .42 .36 .31 .41 .35 .30 .39 .34 30 .287 .52 .40 .33 .27 .51 .40 .32 .27 .38 .32 .27 .37 .31 .27 .36 .31 26 .258 .48 .37 .29 .24 .47 .36 .29 .24 .35 .28 .24 .34 .28 .24 .33 .27 24 .229 .45 .33 .26 .22 .44 .33 .26 .21 .32 .26 .21 .31 .25 .21 .30 .25 21 .1910 .42 .31 .24 .19 .41 .30 .24 .19 .30 .23 .19 .29 .23 .19 .28 .23 19 .18
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 2264.72 19.2 22.90-40 3818.26 32.4 38.70-60 7257.17 61.5 73.50-90 9868.18 83.6 10090-120 0 0 090-130 0 0 090-150 0 0 090-180 0 0 00-180 9868.18 83.6 100
LSI Test Report 21246
229H SERIES MODEL #: 390229H-3546-A
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 2209.49 18.7 27 0-40 3613.34 30.6 44.2 0-60 6413.51 54.4 78.4 0-90 8177.85 69.3 100 90-120 0 0 0 90-130 0 0 0 90-150 0 0 0 90-180 0 0 0 0-180 8177.85 69.3 100
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .83 .83 .83 .83 .81 .81 .81 .81 .77 .77 .77 .74 .74 .74 .71 .71 .71 .691 .75 .72 .69 .66 .73 .70 .68 .65 .67 .65 .63 .65 .63 .61 .62 .61 .59 .582 .68 .63 .58 .54 .67 .61 .57 .53 .59 .55 .52 .57 .53 .51 .54 .52 .50 .483 .62 .55 .49 .45 .61 .54 .48 .44 .52 .47 .43 .50 .46 .43 .48 .45 .42 .404 .57 .49 .42 .38 .55 .48 .42 .37 .46 .41 .37 .44 .40 .36 .43 .39 .36 .345 .52 .43 .37 .32 .51 .43 .37 .32 .41 .36 .32 .40 .35 .32 .38 .34 .31 .306 .48 .39 .33 .28 .47 .38 .32 .28 .37 .32 .28 .36 .31 .28 .35 .31 .27 .267 .45 .35 .29 .25 .44 .35 .29 .25 .34 .28 .25 .33 .28 .24 .32 .27 .24 .238 .42 .32 .26 .22 .41 .32 .26 .22 .31 .26 .22 .30 .25 .22 .29 .25 .22 .209 .39 .30 .24 .20 .38 .29 .24 .20 .28 .23 .20 .28 .23 .20 .27 .23 .20 .1810 .36 .27 .22 .18 .36 .27 .22 .18 .26 .21 .18 .26 .21 .18 .25 .21 .18 .17
WHITE INTERIOR AND FLAT PRISMATIC PLASTIC LENSFOUR PHILIPS 32 WATT T8 LAMPSF32T8/TL841. LUMEN RATING = 2950 LMS.Total Luminaire Efficiency = 69.3%Spacing(0-180) 1.20(90-270) 1.26
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
LSI Test Report 21247
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 3827.38 19.1 22.9 0-40 6452.86 32.3 38.7 0-60 12264.61 61.3 73.5 0-90 16677.24 83.4 100 90-120 0 0 0 90-130 0 0 0 90-150 0 0 0 90-180 0 0 0 0-180 16677.24 83.4 100
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .99 .99 .99 .99 .97 .97 .97 .97 .93 .93 .93 .89 .89 .89 .85 .85 .85 .83 1 .90 .85 .82 .78 .88 .84 .80 .77 .80 .77 .74 .77 .74 .72 .74 .72 .70 .68 2 .81 .74 .67 .62 .79 .72 .66 .61 .69 .64 .60 .66 .62 .59 .64 .60 .57 .55 3 .73 .64 .57 .51 .71 .63 .56 .50 .60 .54 .49 .58 .53 .48 .55 .51 .48 .46 4 .67 .56 .48 .42 .65 .55 .48 .42 .53 .46 .41 .51 .45 .41 .49 .44 .40 .38 5 .61 .50 .42 .36 .59 .49 .41 .36 .47 .40 .35 .45 .39 .35 .44 .39 .35 .33 6 .56 .45 .37 .31 .55 .44 .36 .31 .42 .36 .31 .41 .35 .30 .39 .34 .30 .28 7 .52 .40 .33 .27 .50 .39 .32 .27 .38 .32 .27 .37 .31 .27 .36 .30 .26 .25 8 .48 .37 .29 .24 .47 .36 .29 .24 .35 .28 .24 .34 .28 .24 .33 .27 .23 .22 9 .45 .33 .26 .21 .44 .33 .26 .21 .32 .26 .21 .31 .25 .21 .30 .25 .21 .19 10 .42 .31 .24 .19 .41 .30 .24 .19 .29 .23 .19 .29 .23 .19 .28 .23 .19 .17
WHITE INTERIOR AND NO LENSFOUR PHILIPS 54 WATT T5HO LAMPSF54T5/841/HO/ALTO LUMEN RATING = 5000 LMSTotal Luminaire Efficiency = 83.4%Spacing(0-180) 1.28(90-270) 1.48
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
229H SERIES 390229H-4843 LSI Test Report 21246
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 101
www.ldpi-inc.com
385
770
1154
1539
1
2
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
CC 90 80 70 50 30 10 0
RCR 70 50 30 10 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .93 .93 .93 .93 .91 .91 .91 .91 .89 .89 .89 .89 .85 .85 .85 .81 .81 .81 .78 .78 .78 .761 .86 .82 .79 .76 .84 .81 .78 .75 .82 .79 .76 .74 .76 .74 .72 .73 .71 .69 .70 .69 .67 .662 .79 .73 .68 .63 .77 .71 .66 .62 .75 .70 .65 .62 .67 .63 .60 .65 .62 .59 .62 .60 .58 .563 .72 .64 .58 .53 .70 .63 .57 .53 .69 .62 .56 .52 .60 .55 .51 .57 .54 .50 .56 .52 .50 .484 .66 .57 .50 .45 .64 .56 .50 .45 .63 .55 .49 .44 .53 .48 .44 .51 .47 .43 .50 .46 .43 .415 .61 .50 .43 .38 .59 .49 .43 .38 .57 .48 .42 .37 .47 .41 .37 .45 .40 .37 .44 .40 .36 .356 .56 .45 .38 .33 .54 .44 .37 .32 .52 .43 .37 .32 .42 .36 .32 .40 .35 .32 .39 .35 .31 .307 .51 .40 .33 .29 .50 .39 .33 .28 .48 .39 .32 .28 .37 .32 .28 .36 .31 .27 .35 .31 .27 .268 .47 .36 .29 .24 .46 .35 .29 .24 .44 .34 .28 .24 .33 .28 .24 .33 .27 .24 .32 .27 .23 .229 .43 .32 .25 .21 .42 .32 .25 .21 .41 .31 .25 .21 .30 .24 .20 .29 .24 .20 .28 .24 .20 .1910 .40 .29 .22 .18 .39 .29 .22 .18 .38 .28 .22 .18 .27 .22 .18 .27 .21 .18 .26 .21 .18 .16
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 1244 20.07 26.350-40 2084 33.62 44.150-60 3829 61.76 81.110-90 4721 76.15 100.0040-90 2637 42.53 55.8560-90 892 14.39 18.8990-180 0 0.00 0.000-180 4721 76.15 100.00
Plane1 - (0 - 180)Horizontal2 - (2.5) Vertical
1’ x 4’ LINEAR FLUORESCENT LUMINAIREWITH WHITE INTERIOR,AND CLEAR FLAT GLASS LENS.TWO 32 WATT T8 LAMPS,LUMEN RATING = 3100 LMS.Total Luminaire Efficiency = 76.1%Spacing(0-Deg) 1.28(90-Deg) 1.42
240 SERIES MODEL #: 240-T8-2L-UNV1-TS LSI Test Report 27368
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
480
960
1440
1920
1
2
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
CC 90 80 70 50 30 10 0
RCR 70 50 30 10 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .93 .93 .93 .93 .91 .91 .91 .91 .89 .89 .89 .89 .85 .85 .85 .82 .82 .82 .78 .78 .78 .771 .87 .83 .80 .77 .85 .82 .79 .76 .83 .80 .77 .75 .77 .74 .73 .74 .72 .70 .71 .70 .68 .672 .79 .74 .69 .64 .78 .72 .68 .64 .76 .71 .66 .63 .68 .65 .61 .66 .63 .60 .63 .61 .59 .573 .73 .65 .59 .54 .71 .64 .58 .54 .70 .63 .58 .53 .61 .56 .53 .59 .55 .52 .57 .54 .51 .494 .67 .58 .51 .46 .65 .57 .51 .46 .64 .56 .50 .46 .54 .49 .45 .52 .48 .44 .51 .47 .44 .425 .62 .51 .44 .39 .60 .50 .44 .39 .58 .49 .43 .39 .48 .42 .38 .46 .41 .38 .45 .41 .37 .366 .56 .46 .39 .34 .55 .45 .38 .34 .53 .44 .38 .33 .43 .37 .33 .41 .36 .33 .40 .36 .32 .317 .52 .41 .34 .30 .50 .40 .34 .29 .49 .40 .33 .29 .38 .33 .29 .37 .32 .28 .36 .32 .28 .278 .47 .36 .30 .25 .46 .36 .29 .25 .45 .35 .29 .25 .34 .29 .25 .33 .28 .24 .32 .28 .24 .239 .44 .33 .26 .21 .43 .32 .26 .21 .41 .32 .26 .21 .31 .25 .21 .30 .25 .21 .29 .24 .21 .1910 .40 .30 .23 .19 .39 .29 .23 .19 .38 .29 .23 .19 .28 .22 .19 .27 .22 .18 .26 .22 .18 .17
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 1290 20.81 27.110-40 2226 35.91 46.790-60 3945 63.63 82.910-90 4758 76.74 100.0040-90 2532 40.83 53.2160-90 813 13.11 17.0990-180 0 0.00 0.000-180 4758 76.74 100.00
Plane1 - (90 - 270)
Horizontal2 - (25) Vertical
1’ x 4’ LINEAR FLUORESCENT LUMINAIRE,WITH SPECULAR REFLECTOR,AND CLEAR FLAT GLASS LENS.TWO 32 WATT T8 LAMPS,LUMEN RATING = 3100 LMS.Total Luminaire Efficiency = 76.7%Spacing(0-Deg) 1.26(90-Deg) 1.62
240 SERIES MODEL #: 240-T8-2L-UNV1-TS-SR LSI Test Report 27370
812
162
2437
32 9
1
2
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
CC 80 70 50 30 10 0
RCR 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .81 .81 .81 .81 .79 .79 .79 .79 .76 .76 .76 .72 .72 .72 .69 .69 .69 .68 1 .74 .71 .69 .66 .73 .70 .67 .65 .67 .65 .63 .64 .63 .61 .62 .60 .59 .58 2 .68 .62 .58 .54 .66 .61 .57 .53 .59 .55 .52 .56 .53 .51 .54 .52 .50 .48 3 .62 .55 .49 .45 .60 .54 .48 .44 .51 .47 .44 .50 .46 .43 .48 .45 .42 .41 4 .56 .48 .42 .38 .55 .47 .42 .38 .46 .41 .37 .44 .40 .37 .43 .39 .36 .35 5 .52 .43 .37 .32 .50 .42 .37 .32 .41 .36 .32 .39 .35 .32 .38 .34 .31 .30 6 .48 .39 .33 .28 .46 .38 .32 .28 .37 .32 .28 .36 .31 .28 .35 .30 .27 .26 7 .44 .35 .29 .25 .43 .34 .29 .25 .33 .28 .25 .32 .28 .24 .31 .27 .24 .23 8 .41 .32 .26 .22 .40 .31 .26 .22 .30 .25 .22 .30 .25 .22 .29 .25 .22 .20 9 .38 .29 .24 .20 .37 .29 .23 .20 .28 .23 .20 .27 .23 .19 .26 .22 .19 .18 10 .36 .27 .21 .18 .35 .26 .21 .18 .26 .21 .18 .25 .21 .18 .25 .20 .17 .16
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 1135.4 9.2 13.530-60 2289.9 18.5 27.260-80 766.0 6.2 9.180-90 24.9 0.2 0 .390-100 0.0 0.0 0.0100-180 0.0 0.0 0.0
Plane1 - (90 - 270)
Horizontal2 - (25) Vertical
HEAVy DUTy SEALED INDUSTRIAL LUMINAIRE WITH SPECULAR REFLECTORAND FLAT CLEAR GLASS LENSFOUR 32 WATT T8 LAMPS LUMEN RATING = 3100 LMS.Total Luminaire Efficiency = 84%Spacing(0-Deg) 1.25(90-Deg) 1.60
240 SERIES MODEL #: 240-T8-4L-4-UNV1-SR LSI Test Report 24910
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012102
www.ldpi-inc.com
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
717
1434
2151
2869
1
2
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
CC 90 80 70 50 30 10 0
RCR 70 50 30 10 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .88 .88 .88 .88 .86 .86 .86 .86 .84 .84 .84 .84 .80 .80 .80 .77 .77 .77 .73 .73 .73 .721 .81 .77 .74 .72 .79 .76 .73 .71 .77 .74 .72 .69 .71 .69 .67 .68 .67 .65 .66 .65 .63 .622 .74 .68 .63 .59 .72 .67 .62 .58 .71 .65 .61 .58 .63 .59 .56 .61 .58 .55 .59 .56 .54 .523 .68 .60 .54 .50 .66 .59 .53 .49 .64 .58 .53 .49 .56 .51 .48 .54 .50 .47 .52 .49 .46 .454 .62 .53 .47 .42 .61 .52 .46 .42 .59 .51 .46 .41 .50 .45 .41 .48 .44 .40 .46 .43 .40 .385 .57 .47 .40 .35 .55 .46 .40 .35 .54 .45 .39 .35 .44 .38 .34 .42 .38 .34 .41 .37 .34 .326 .52 .42 .35 .31 .51 .41 .35 .30 .49 .40 .34 .30 .39 .34 .30 .38 .33 .29 .37 .32 .29 .287 .48 .37 .31 .27 .47 .37 .31 .26 .45 .36 .30 .26 .35 .30 .26 .34 .29 .25 .33 .29 .25 .248 .44 .33 .27 .23 .43 .33 .27 .22 .42 .32 .26 .22 .31 .26 .22 .31 .26 .22 .30 .25 .22 .209 .40 .30 .24 .19 .39 .30 .23 .19 .38 .29 .23 .19 .28 .23 .19 .27 .22 .19 .27 .22 .19 .1710 .37 .27 .21 .17 .36 .27 .21 .17 .36 .26 .21 .17 .26 .20 .17 .25 .20 .17 .24 .20 .16 .15
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 2322 18.73 26.040-40 3885 31.33 43.570-60 7125 57.46 79.910-90 8917 71.91 100.0040-90 5032 40.58 56.4360-90 1792 14.45 20.0990-180 0 0.00 0.000-180 8917 71.91 100.00
Plane1 - (67.5 - 247.5)
Horizontal2 - (10) Vertical
4’ LINEAR FLUORESCENT LUMINAIRE,WITH WHITE INTERIORAND CLEAR FLAT GLASS LENSFOUR 32 WATT T8 LAMPS,LUMEN RATING = 3100 LMS.Total Luminaire Efficiency = 71.9%Spacing(0-Deg) 1.28(90-Deg) 1.41
240 SERIES MODEL #: 240-T8-4L-UNV1-TS LSI Test Report 27371
1022
204
3067
089
1
2
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
CC 90 80 70 50 30 10 0
RCR 70 50 30 10 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .84 .84 .84 .84 .82 .82 .82 .82 0.80 .80 .80 .80 .77 .77 .77 .74 .74 .74 .71 .71 .71 .691 .78 .74 .71 .69 .76 .73 .70 .68 .74 .71 .69 .67 .68 .66 .65 .66 .64 .63 .63 .62 .61 .592 .71 .65 .61 .57 .69 .64 .60 .56 .68 .63 .59 .55 .60 .57 .54 .58 .55 .53 .56 .54 .52 .503 .65 .58 .52 .47 .63 .56 .51 .47 .62 .55 .51 .47 .53 .49 .46 .52 .48 .45 .50 .47 .44 .434 .60 .51 .45 .40 .58 .50 .44 .40 .57 .49 .44 .39 .47 .43 .39 .46 .42 .38 .44 .41 .38 .365 .55 .45 .38 .34 .53 .44 .38 .33 .51 .43 .37 .33 .42 .37 .33 .40 .36 .32 .39 .35 .32 .316 .50 .40 .34 .29 .49 .39 .33 .29 .47 .39 .33 .29 .37 .32 .28 .36 .32 .28 .35 .31 .28 .267 .46 .36 .29 .25 .45 .35 .29 .25 .44 .35 .29 .25 .34 .28 .25 .32 .28 .24 .32 .27 .24 .238 .42 .32 .26 .22 .41 .31 .26 .21 .40 .31 .25 .21 .30 .25 .21 .29 .24 .21 .28 .24 .21 .199 .39 .29 .22 .18 .38 .28 .22 .18 .37 .28 .22 .18 .27 .22 .18 .26 .21 .18 .25 .21 .18 .1710 .36 .26 .20 .16 .35 .26 .20 .16 .34 .25 .20 .16 .24 .19 .16 .24 .19 .16 .23 .19 .16 .14
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 3303 17.76 25.670-40 5530 29.73 42.980-60 10182 54.74 79.130-90 12867 69.18 100.0040-90 7337 39.45 57.0260-90 2685 14.44 20.8790-180 0 0.00 0.000-180 12867 69.18 100.00
Plane1 - (67.5 - 247.5)
Horizontal2 - (7.5) Vertical
2’ x 4’ LINEAR FLUORESCENT LUMINAIREWITH WHITE INTERIORAND CLEAR FLAT GLASS LENSSIX 32 WATT T8 LAMPS,LUMEN RATING = 3100 LMS.Total Luminaire Efficiency = 69.2%Spacing(0-Deg) 1.28(90-Deg) 1.42
240 SERIES MODEL #: 240-T8-6L-UNV1-TS LSI Test Report 27369
1168
2335
3503
4671
1
2
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
CC 90 80 70 50 30 10 0
RCR 70 50 30 10 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .81 .81 .81 .81 .79 .79 .79 .79 .77 .77 .77 .77 .74 .74 .74 .71 .71 .71 .68 .68 .68 .661 .75 .71 .69 .66 .73 .70 .68 .65 .71 .69 .66 .64 .66 .64 .62 .63 .62 .60 .61 .60 .58 .572 .68 .63 .59 .55 .67 .62 .58 .54 .65 .60 .57 .53 .58 .55 .52 .56 .53 .51 .54 .52 .50 .483 .63 .55 .50 .46 .61 .54 .49 .45 .59 .53 .49 .45 .52 .48 .44 .50 .46 .44 .48 .45 .43 .414 .57 .49 .43 .39 .56 .48 .43 .39 .55 .48 .42 .38 .46 .41 .38 .44 .40 .37 .43 .40 .37 .355 .53 .44 .37 .33 .51 .43 .37 .32 .50 .42 .36 .32 .40 .36 .32 .39 .35 .32 .38 .34 .31 .306 .48 .39 .33 .28 .47 .38 .32 .28 .46 .37 .32 .28 .36 .31 .28 .35 .31 .27 .34 .30 .27 .267 .44 .35 .29 .25 .43 .34 .28 .24 .42 .34 .28 .24 .33 .27 .24 .31 .27 .24 .31 .27 .23 .228 .41 .31 .25 .21 .40 .30 .25 .21 .39 .30 .25 .21 .29 .24 .21 .28 .24 .20 .27 .23 .20 .199 .37 .28 .22 .18 .36 .27 .22 .18 .35 .27 .22 .18 .26 .21 .18 .25 .21 .18 .25 .21 .17 .1610 .34 .25 .19 .16 .34 .25 .19 .16 .33 .24 .19 .16 .24 .19 .16 .23 .19 .15 .22 .18 .15 .14
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 3250 17.47 26.330-40 5545 29.81 44.940-60 9891 53.18 80.150-90 12341 66.35 100.0040-90 6795 36.53 55.0660-90 2450 13.17 19.8590-180 0 0.00 0.000-180 12341 66.35 100.00
Plane1 - (90 - 270)
Horizontal2 - (25) Vertical
2’ x 4’ LINEAR FLUORESCENT LUMINAIREWITH SPECULAR REFLECTORAND CLEAR FLAT GLASS LENSSIX 32 WATT T8 LAMPS,LUMEN RATING = 3100 LMS.Total Luminaire Efficiency = 66.3%Spacing(0-Deg) 1.25(90-Deg) 1.60
240 SERIES MODEL #: 240-T8-6L-UNV1-TS-SR LSI Test Report 27367
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 103
www.ldpi-inc.com
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
241 SERIES MODEL #: 390241120-3260
FABRICATED METAL HOUSINGWHITE PAINTED REFLECTORCLEAR FLAT GLASS ENCLOSURE.FOUR F48T12/CW, EACH RATED 4300 LUMENS.MOUNTING: RECESSEDTotal Luminaire Efficiency = 43.6%Spacing(0-180) 1.28(90-270) 1.34
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .69 .69 .69 .69 .67 .67 .67 .67 .64 .64 .64 .62 .62 .62 .59 .59 .59 .58 1 .64 .61 .59 .56 .62 .60 .57 .56 .57 .55 .54 .55 .53 .52 .53 .52 .51 .49 2 .58 .53 .49 .46 .56 .52 .49 .46 .50 .47 .45 .48 .46 .44 .46 .44 .43 .41 3 .53 .47 .42 .38 .51 .46 .42 .38 .44 .40 .37 .43 .39 .37 .41 .38 .36 .35 4 .48 .41 .36 .33 .47 .41 .36 .32 .39 .35 .32 .38 .34 .31 .37 .34 .31 .30 5 .44 .37 .32 .28 .43 .36 .31 .28 .35 .31 .28 .34 .30 .27 .33 .30 .27 .26 6 .41 .33 .28 .24 .40 .33 .28 .24 .32 .27 .24 .31 .27 .24 .30 .26 .24 .22 7 .38 .30 .25 .21 .37 .30 .25 .21 .29 .24 .21 .28 .24 .21 .27 .24 .21 .20 8 .35 .27 .22 .19 .34 .27 .22 .19 .26 .22 .19 .26 .22 .19 .25 .21 .19 .18 9 .33 .25 .20 .17 .32 .25 .20 .17 .24 .20 .17 .23 .20 .17 .23 .19 .17 .16 10 .31 .23 .19 .15 .30 .23 .18 .15 .22 .18 .15 .22 .18 .15 .21 .18 .15 .14
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 2002.3 15.9 27.4 0-40 3330.78 26.4 45.6 0-60 6010.04 47.7 82.2 0-90 7311.11 58 100 90-120 0 0 0 90-130 0 0 0 90-150 0 0 0 90-180 0 0 0 0-180 7311.11 58 100
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
ITL Test Report 34242
260/261 SERIES MODEL #: 390260/261120-1748
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .66 .66 .66 .66 .64 .64 .64 .64 .61 .61 .61 .59 .59 .59 .56 .56 .56 .551 .60 .58 .56 .54 .59 .57 .55 .53 .54 .53 .51 .52 .51 .50 .50 .49 .48 .472 .55 .51 .47 .44 .54 .50 .46 .44 .48 .45 .43 .46 .44 .42 .44 .42 .41 .393 .50 .45 .40 .37 .49 .44 .40 .36 .42 .39 .36 .41 .38 .35 .39 .37 .34 .334 .46 .39 .35 .31 .45 .39 .34 .31 .37 .33 .30 .36 .33 .30 .35 .32 .30 .285 .42 .35 .30 .27 .41 .35 .30 .26 .33 .29 .26 .32 .29 .26 .31 .28 .26 .246 .39 .32 .27 .23 .38 .31 .26 .23 .30 .26 .23 .29 .25 .23 .28 .25 .22 .217 .36 .29 .24 .20 .35 .28 .24 .20 .27 .23 .20 .26 .23 .20 .26 .22 .20 .198 .33 .26 .21 .18 .33 .26 .21 .18 .25 .21 .18 .24 .20 .18 .24 .20 .18 .179 .31 .24 .19 .16 .30 .23 .19 .16 .23 .19 .16 .22 .19 .16 .22 .18 .16 .1510 .29 .22 .18 .15 .29 .22 .17 .15 .21 .17 .15 .21 .17 .14 .20 .17 .14 .13
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 1822.53 14.9 27.1 0-40 3038.99 24.9 45.1 0-60 5547.29 45.5 82.4 0-90 6731.85 55.2 100 90-120 0 0 0 90-130 0 0 0 90-150 0 0 0 90-180 0 0 0 0-180 6731.85 55.2 100
FABRICATED METAL HOUSINGWHITE PAINTED INTERIOR REFLECTOR FINISHCLEAR TEMPERED GLASS ENCLOSURE IN ALUMINUM DOOR FRAME.FOUR F40T12/CW, EACH RATED 3050 LUMENS.RECESSEDTotal Luminaire Efficiency = 55.2%Spacing(0-180) 1.28(90-270) 1.42
ITL Test Report 38623
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .57 .57 .57 .57 .55 .55 .55 .55 .53 .53 .53 .51 .51 .51 .49 .49 .49 .48 1 .52 .50 .48 .46 .51 .49 .47 .46 .47 .45 .44 .45 .44 .43 .43 .42 .41 .41 2 .47 .44 .40 .38 .46 .43 .40 .37 .41 .39 .37 .39 .37 .36 .38 .36 .35 .34 3 .43 .38 .34 .31 .42 .38 .34 .31 .36 .33 .31 .35 .32 .30 .34 .31 .30 .29 4 .39 .34 .30 .27 .38 .33 .29 .26 .32 .29 .26 .31 .28 .26 .30 .27 .25 .24 5 .36 .30 .26 .23 .35 .30 .26 .23 .29 .25 .22 .28 .25 .22 .27 .24 .22 .21 6 .33 .27 .23 .20 .32 .27 .23 .20 .26 .22 .20 .25 .22 .19 .24 .21 .19 .18 7 .31 .24 .20 .17 .30 .24 .20 .17 .23 .20 .17 .23 .19 .17 .22 .19 .17 .16 8 .29 .22 .18 .15 .28 .22 .18 .15 .21 .18 .15 .21 .18 .15 .20 .17 .15 .14 9 .27 .20 .16 .14 .26 .20 .16 .14 .20 .16 .14 .19 .16 .14 .19 .16 .14 .13 10 .25 .19 .15 .13 .24 .19 .15 .12 .18 .15 .12 .18 .15 .12 .17 .14 .12 .11
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 2189.5 12.7 26.8 0-40 3654.86 21.2 44.7 0-60 6698.14 38.9 81.9 0-90 8177.04 47.5 100 90-120 0 0 0 90-130 0 0 0 90-150 0 0 0 90-180 0 0 0 0-180 8177.04 47.5 100
FABRICATED METAL HOUSINGWHITE PAINTED INTERIOR REFLECTORCLEAR FLAT TEMPERED GLASS ENCLOSURE IN ALUMINUM DOOR FRAME.FOUR F48T12/CW/HO, EACH RATED 4300 LUMENS.Total Luminaire Efficiency = 47.5%Spacing(0-180) 1.28(90-270) 1.42
260/261 SERIES MODEL #: 390260/261120-3260 ITL Test Report 38624
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012104
www.ldpi-inc.com
280/281 SERIES MODEL #: 390280/281120-3260
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
FABRICATED METAL HOUSINGWHITE PAINTED INTERIOR REFLECTOR FINISHCLEAR TEMPERED GLASS ENCLOSURES IN ALUMINUM DOOR FRAMESFOUR F96T12/CW/HO, EACH RATED 8800 LUMENS.RECESSEDTotal Luminaire Efficiency = 57.8%Spacing(0-180) 1.26(90-270) 1.42
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .69 .69 .69 .69 .67 .67 .67 .67 .64 .64 .64 .61 .61 .61 .59 .59 .59 .58 1 .63 .61 .58 .56 .62 .59 .57 .55 .57 .55 .54 .55 .53 .52 .53 .52 .50 .49 2 .58 .53 .49 .46 .56 .52 .48 .46 .50 .47 .44 .48 .46 .43 .46 .44 .42 .41 3 .53 .47 .42 .38 .51 .46 .41 .38 .44 .40 .37 .42 .39 .37 .41 .38 .36 .35 4 .48 .41 .36 .32 .47 .40 .36 .32 .39 .35 .32 .38 .34 .31 .36 .33 .31 .30 5 .44 .37 .32 .28 .43 .36 .31 .28 .35 .31 .27 .34 .30 .27 .33 .29 .27 .26 6 .41 .33 .28 .24 .40 .33 .28 .24 .31 .27 .24 .31 .27 .24 .30 .26 .23 .22 7 .38 .30 .25 .21 .37 .29 .25 .21 .29 .24 .21 .28 .24 .21 .27 .23 .21 .20 8 .35 .27 .22 .19 .34 .27 .22 .19 .26 .22 .19 .25 .22 .19 .25 .21 .19 .17 9 .33 .25 .20 .17 .32 .25 .20 .17 .24 .20 .17 .23 .20 .17 .23 .19 .17 .16 10 .31 .23 .18 .15 .30 .23 .18 .15 .22 .18 .15 .22 .18 .15 .21 .18 .15 .14
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 5551.21 15.8 27.3 0-40 9231.33 26.2 45.4 0-60 16706.64 47.5 82.1 0-90 20345.8 57.8 100 90-120 0 0 0 90-130 0 0 0 90-150 0 0 0 90-180 0 0 0 0-180 20345.8 57.8 100
ITL Test Report 39896
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
FABRICATED METAL HOUSING WITH WHITE PAINTED INTERIOR FINISHWHITE PAINTED FABRICATED METAL BALLAST COVERCLEAR FLAT GLASS LENS IN EXTRUDED METAL DOOR FRAME.TWO 25-WATT T-8 F25T8 LINEAR FLUORESCENTS. RECESSEDTotal Luminaire Efficiency = 58.6%Spacing(0-180) 1.28(90-270) 1.30
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .70 .70 .70 .70 .68 .68 .68 .68 .65 .65 .65 .62 .62 .62 .60 .60 .60 .59 1 .64 .62 .59 .57 .63 .60 .58 .56 .58 .56 .54 .55 .54 .53 .53 .52 .51 .50 2 .59 .54 .50 .47 .57 .53 .49 .46 .51 .48 .45 .49 .46 .44 .47 .45 .43 .42 3 .53 .48 .43 .39 .52 .47 .42 .39 .45 .41 .38 .43 .40 .38 .42 .39 .37 .36 4 .49 .42 .37 .33 .48 .41 .37 .33 .40 .36 .33 .39 .35 .32 .37 .34 .32 .31 5 .45 .38 .33 .29 .44 .37 .32 .29 .36 .32 .28 .35 .31 .28 .34 .30 .28 .26 6 .42 .34 .29 .25 .41 .33 .29 .25 .32 .28 .25 .31 .28 .25 .30 .27 .24 .23 7 .39 .31 .26 .22 .38 .30 .26 .22 .29 .25 .22 .29 .25 .22 .28 .24 .22 .20 8 .36 .28 .23 .20 .35 .28 .23 .20 .27 .23 .20 .26 .22 .20 .26 .22 .19 .18 9 .34 .26 .21 .18 .33 .25 .21 .18 .25 .21 .18 .24 .20 .18 .24 .20 .17 .16 10 .31 .24 .19 .16 .31 .23 .19 .16 .23 .19 .16 .22 .19 .16 .22 .18 .16 .15
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 750.69 16.9 28.8 0-40 1234.02 27.7 47.4 0-60 2155.38 48.4 82.7 0-90 2605.64 58.6 100 90-120 0 0 0 90-130 0 0 0 90-150 0 0 0 90-180 0 0 0 0-180 2605.64 58.6 100
300 SLIM LIGHT SERIES MODEL #: 390320-3613 ITL Test Report 48522
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
FABRICATED METAL HOUSING WITH WHITE PAINTED INTERIOR FINISHWHITE PAINTED FABRICATED METAL BALLAST COVERCLEAR FLAT GLASS LENS IN EXTRUDED METAL DOOR FRAMEFOUR 25-WATT T-8 F25T8 LINEAR FLUORESCENTS.RECESSEDTotal Luminaire Efficiency = 64%Spacing(0-180) 1.28(90-270) 1.38
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .76 .76 .76 .76 .74 .74 .74 .74 .71 .71 .71 .68 .68 .68 .65 .65 .65 .64 1 .70 .67 .64 .62 .68 .65 .63 .61 .63 .61 .59 .60 .59 .57 .58 .57 .55 .54 2 .64 .58 .54 .50 .62 .57 .53 .50 .55 .52 .49 .53 .50 .48 .51 .49 .47 .45 3 .58 .51 .46 .42 .56 .50 .45 .41 .48 .44 .41 .46 .43 .40 .45 .42 .39 .38 4 .53 .45 .40 .35 .51 .44 .39 .35 .43 .38 .35 .41 .37 .34 .40 .37 .34 .32 5 .49 .40 .35 .30 .47 .40 .34 .30 .38 .33 .30 .37 .33 .30 .36 .32 .29 .28 6 .45 .36 .31 .26 .44 .36 .30 .26 .34 .30 .26 .33 .29 .26 .32 .29 .26 .24 7 .41 .33 .27 .23 .40 .32 .27 .23 .31 .26 .23 .30 .26 .23 .29 .26 .23 .21 8 .39 .30 .24 .21 .38 .29 .24 .21 .29 .24 .20 .28 .23 .20 .27 .23 .20 .19 9 .36 .27 .22 .19 .35 .27 .22 .18 .26 .22 .18 .26 .21 .18 .25 .21 .18 .17 10 .34 .25 .20 .17 .33 .25 .20 .17 .24 .20 .17 .24 .19 .17 .23 .19 .16 .15
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 1523.71 17.1 26.8 0-40 2536.83 28.5 44.6 0-60 4588.74 51.6 80.6 0-90 5692.03 64 100 90-120 0 0 0 90-130 0 0 0 90-150 0 0 0 90-180 0 0 0 0-180 5692.03 64 100
300 SLIM LIGHT SERIES MODEL #: 390340-3546 ITL Test Report 48518
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 105
www.ldpi-inc.com
300 SLIM LIGHT SERIES MODEL #: 390360-3546
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .78 .78 .78 .78 .76 .76 .76 .76 .73 .73 .73 .70 .70 .70 .67 .67 .67 .65 1 .71 .68 .66 .63 .70 .67 .64 .62 .64 .62 .60 .61 .60 .58 .59 .58 .57 .55 2 .65 .59 .55 .51 .63 .58 .54 .51 .56 .52 .49 .54 .51 .48 .52 .49 .47 .46 3 .59 .52 .47 .42 .57 .51 .46 .42 .49 .45 .41 .47 .44 .41 .46 .42 .40 .38 4 .54 .46 .40 .36 .52 .45 .40 .35 .43 .39 .35 .42 .38 .35 .40 .37 .34 .33 5 .49 .41 .35 .31 .48 .40 .35 .30 .39 .34 .30 .38 .33 .30 .36 .32 .29 .28 6 .46 .37 .31 .27 .44 .36 .31 .26 .35 .30 .26 .34 .29 .26 .33 .29 .26 .24 7 .42 .33 .27 .23 .41 .33 .27 .23 .32 .27 .23 .31 .26 .23 .30 .26 .23 .21 8 .39 .30 .25 .21 .38 .30 .24 .21 .29 .24 .21 .28 .24 .20 .27 .23 .20 .19 9 .37 .28 .22 .19 .36 .27 .22 .19 .27 .22 .18 .26 .21 .18 .25 .21 .18 .17 10 .34 .26 .20 .17 .33 .25 .20 .17 .25 .20 .17 .24 .20 .17 .23 .19 .17 .15
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 2280.66 17.1 26.1 0-40 3810.33 28.5 43.6 0-60 6955.27 52.1 79.6 0-90 8739.76 65.5 100 90-120 0 0 0 90-130 0 0 0 90-150 0 0 0 90-180 0 0 0 0-180 8739.76 65.5 100
FABRICATED METAL HOUSING WITH WHITE PAINTED INTERIOR FINISHWHITE PAINTED FABRICATED METAL BALLAST COVERCLEAR FLAT GLASS LENS IN EXTRUDED METAL DOOR FRAME.SIX 25-WATT T-8 F25T8 LINEAR FLUORESCENTS. RECESSEDTotal Luminaire Efficiency = 65.5%Spacing(0-180) 1.28(90-270) 1.42
ITL Test Report 48520
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .70 .70 .70 .70 .68 .68 .68 .68 .65 .65 .65 .62 .62 .62 .60 .60 .60 .59 1 .64 .62 .59 .57 .63 .60 .58 .56 .58 .56 .54 .55 .54 .53 .53 .52 .51 .50 2 .59 .54 .50 .47 .57 .53 .49 .46 .51 .48 .45 .49 .46 .44 .47 .45 .43 .42 3 .53 .48 .43 .39 .52 .47 .42 .39 .45 .41 .38 .43 .40 .38 .42 .39 .37 .36 4 .49 .42 .37 .33 .48 .41 .37 .33 .40 .36 .33 .39 .35 .32 .37 .34 .32 .31 5 .45 .38 .33 .29 .44 .37 .32 .29 .36 .32 .28 .35 .31 .28 .34 .30 .28 .26 6 .42 .34 .29 .25 .41 .33 .29 .25 .32 .28 .25 .31 .28 .25 .30 .27 .24 .23 7 .39 .31 .26 .22 .38 .30 .26 .22 .29 .25 .22 .29 .25 .22 .28 .24 .22 .20 8 .36 .28 .23 .20 .35 .28 .23 .20 .27 .23 .20 .26 .22 .20 .26 .22 .19 .18 9 .34 .26 .21 .18 .33 .25 .21 .18 .25 .21 .18 .24 .20 .18 .24 .20 .17 .16 10 .31 .24 .19 .16 .31 .23 .19 .16 .23 .19 .16 .22 .19 .16 .22 .18 .16 .15
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 1029.03 16.9 28.8 0-40 1691.53 27.7 47.4 0-60 2954.41 48.4 82.7 0-90 3571.56 58.6 100 90-120 0 0 0 90-130 0 0 0 90-150 0 0 0 90-180 0 0 0 0-180 3571.56 58.6 100
FABRICATED METAL HOUSING WITH WHITE PAINTED INTERIOR FINISHWHITE PAINTED FABRICATED METAL BALLAST COVERCLEAR FLAT GLASS LENS IN EXTRUDED METAL DOOR FRAMETWO 32-WATT T-8 F32T8/TL835 LINEAR FLUORESCENTSTotal Luminaire Efficiency = 58.6%Spacing(0-180) 1.28(90-270) 1.30
400 SLIM LIGHT SERIES MODEL #: 390420-3613 ITL Test Report 48516
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .74 .74 .74 .74 .72 .72 .72 .72 .69 .69 .69 .66 .66 .66 .63 .63 .63 .62 1 .67 .65 .62 .60 .66 .63 .61 .59 .61 .59 .57 .58 .57 .55 .56 .55 .54 .52 2 .61 .56 .52 .49 .60 .55 .51 .48 .53 .50 .47 .51 .48 .46 .49 .47 .45 .44 3 .56 .49 .44 .41 .54 .48 .44 .40 .47 .43 .39 .45 .42 .39 .43 .41 .38 .37 4 .51 .44 .38 .34 .50 .43 .38 .34 .41 .37 .34 .40 .36 .33 .39 .35 .33 .31 5 .47 .39 .33 .29 .46 .38 .33 .29 .37 .32 .29 .36 .32 .29 .35 .31 .28 .27 6 .43 .35 .30 .26 .42 .34 .29 .25 .33 .29 .25 .32 .28 .25 .31 .28 .25 .24 7 .40 .32 .26 .23 .39 .31 .26 .22 .30 .26 .22 .29 .25 .22 .29 .25 .22 .21 8 .37 .29 .24 .20 .36 .28 .23 .20 .28 .23 .20 .27 .23 .20 .26 .22 .20 .18 9 .35 .27 .21 .18 .34 .26 .21 .18 .25 .21 .18 .25 .21 .18 .24 .20 .18 .17 10 .33 .24 .20 .16 .32 .24 .19 .16 .23 .19 .16 .23 .19 .16 .22 .19 .16 .15
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 1966.75 16.7 27 0-40 3269.92 27.7 44.9 0-60 5886.8 49.9 80.8 0-90 7286.57 61.8 100 90-120 0 0 0 90-130 0 0 0 90-150 0 0 0 90-180 0 0 0 0-180 7286.57 61.8 100
WITH WHITE INTERIOR AND CLEAR FLAT GLASS LENSFOUR PHILIPS 32 WATT T8 LAMPSF32T8/TL850. LUMEN RATING = 2950 LMS.Total Luminaire Efficiency = 61.8%Spacing(0-180) 1.28(90-270) 1.38
LSI Test Report 19911400 SLIM LIGHT SERIES MODEL #: 390440-3546
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012106
www.ldpi-inc.com
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .78 .78 .78 .78 .76 .76 .76 .76 .73 .73 .73 .70 .70 .70 .67 .67 .67 .65 1 .71 .68 .66 .63 .70 .67 .64 .62 .64 .62 .60 .61 .60 .58 .59 .58 .57 .55 2 .65 .59 .55 .51 .63 .58 .54 .51 .56 .52 .49 .54 .51 .48 .52 .49 .47 .46 3 .59 .52 .47 .42 .57 .51 .46 .42 .49 .45 .41 .47 .44 .41 .46 .42 .40 .38 4 .54 .46 .40 .36 .52 .45 .40 .35 .43 .39 .35 .42 .38 .35 .40 .37 .34 .33 5 .49 .41 .35 .31 .48 .40 .35 .30 .39 .34 .30 .38 .33 .30 .36 .32 .29 .28 6 .46 .37 .31 .27 .44 .36 .31 .26 .35 .30 .26 .34 .29 .26 .33 .29 .26 .24 7 .42 .33 .27 .23 .41 .33 .27 .23 .32 .27 .23 .31 .26 .23 .30 .26 .23 .21 8 .39 .30 .25 .21 .38 .30 .24 .21 .29 .24 .21 .28 .24 .20 .27 .23 .20 .19 9 .37 .28 .22 .19 .36 .27 .22 .19 .27 .22 .18 .26 .21 .18 .25 .21 .18 .17 10 .34 .26 .20 .17 .33 .25 .20 .17 .25 .20 .17 .24 .20 .17 .23 .19 .17 .15
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 3126.34 17.1 26.1 0-40 5223.16 28.5 43.6 0-60 9534.15 52.1 79.6 0-90 11980.19 65.5 100 90-120 0 0 0 90-130 0 0 0 90-150 0 0 0 90-180 0 0 0 0-180 11980.19 65.5 100
FABRICATED METAL HOUSING WITH WHITE PAINTED INTERIOR FINISHWHITE PAINTED FABRICATED METAL BALLAST COVERCLEAR FLAT GLASS LENS IN EXTRUDED METAL DOOR FRAME.SIX 32-WATT T-8 F32T8/TL835 LINEAR FLUORESCENTS.Total Luminaire Efficiency = 65.5%Spacing(0-180) 1.28(90-270) 1.42
400 SLIM LIGHT SERIES MODEL #: 390460-3546 ITL Test Report 48515
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
888
776
2664
3552
1
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .86 .86 .86 .86 .84 .84 .84 .84 .81 .81 .81 .77 .77 .77 .74 .74 .74 .72 1 .80 .77 .74 .72 .78 .75 .73 .71 .72 .70 .68 .69 .68 .66 .67 .66 .64 .63 2 .73 .68 .64 .60 .71 .67 .63 .59 .64 .61 .58 .62 .59 .56 .60 .57 .55 .54 3 .67 .60 .55 .51 .66 .59 .54 .50 .57 .53 .49 .55 .51 .48 .53 .50 .48 .46 4 .62 .54 .48 .43 .60 .53 .47 .43 .51 .46 .43 .49 .45 .42 .48 .44 .41 .40 5 .57 .48 .42 .38 .56 .48 .42 .38 .46 .41 .37 .45 .40 .37 .43 .40 .36 .35 6 .53 .44 .38 .33 .52 .43 .37 .33 .42 .37 .33 .41 .36 .33 .39 .35 .32 .31 7 .49 .40 .34 .30 .48 .39 .33 .29 .38 .33 .29 .37 .32 .29 .36 .32 .29 .27 8 .46 .36 .31 .26 .45 .36 .30 .26 .35 .30 .26 .34 .29 .26 .33 .29 .26 .25 9 .43 .33 .28 .24 .42 .33 .28 .24 .32 .27 .24 .31 .27 .24 .31 .27 .23 .22 10 .40 .31 .25 .22 .39 .31 .25 .22 .30 .25 .22 .29 .25 .22 .29 .24 .21 .20
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 2807.9 23.4 32.30-40 4547.4 37.9 52.30-60 7505.7 62.5 86.360-90 1190.6 9.9 13.70-90 8696.3 72.5 100.090-180 0.0 0.0 0.00-180 8696.3 72.5 100.0
FABRICATED METAL HOUSING WITH MIRO 4 SPECULAR REFLECTORWITH CLEAR FLAT GLASS LENS IN EXTRUDED METAL DOOR FRAME.FOUR GE 32-WATT T-8 LAMPSLINEAR FLUORESCENTS.Total Luminaire Efficiency = 72.5%Spacing(0-Deg) 1.26(90-Deg) 1.23
400 SLIM LIGHT SERIES MODEL #: 390440-3546 LSI Test Report 26138
711
1422
2133
2844
2
1
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .78 .78 .78 .78 .76 .76 .76 .76 .73 .73 .73 .70 .70 .70 .67 .67 .67 .66 1 .72 .69 .67 .64 .70 .68 .65 .63 .65 .63 .61 .62 .61 .59 .60 .59 .58 .56 2 .66 .61 .57 .53 .64 .59 .56 .52 .57 .54 .51 .55 .52 .50 .53 .51 .49 .48 3 .60 .54 .48 .44 .59 .53 .48 .44 .51 .47 .43 .49 .45 .42 .47 .44 .42 .40 4 .55 .48 .42 .38 .54 .47 .41 .37 .45 .41 .37 .44 .40 .36 .42 .39 .36 .35 5 .51 .42 .37 .33 .49 .42 .36 .32 .40 .36 .32 .39 .35 .32 .38 .34 .31 .30 6 .47 .38 .33 .28 .46 .38 .32 .28 .36 .32 .28 .35 .31 .28 .34 .31 .28 .26 7 .43 .35 .29 .25 .42 .34 .29 .25 .33 .28 .25 .32 .28 .25 .31 .27 .24 .23 8 .40 .32 .26 .22 .39 .31 .26 .22 .30 .26 .22 .30 .25 .22 .29 .25 .22 .21 9 .38 .29 .24 .20 .37 .29 .24 .20 .28 .23 .20 .27 .23 .20 .27 .23 .20 .19 10 .35 .27 .22 .18 .34 .26 .21 .18 .26 .21 .18 .25 .21 .18 .25 .21 .18 .17
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 2267.8 18.9 28.80-40 3753.2 31.3 47.70-60 6605.2 55.0 83.960-90 1267.7 10.6 16.10-90 7872.9 65.6 100.090-180 0.0 0.0 0.00-180 7872.9 65.6 100.0
FABRICATED METAL HOUSING WITH WHITE REFLECTORWITH CLEAR FLAT GLASS LENS IN EXTRUDED METAL DOOR FRAME.FOUR GE 32-WATT T-8 LAMPSLINEAR FLUORESCENTS.Total Luminaire Efficiency = 65.6%Spacing(0-Deg) 1.29(90-Deg) 1.32
400 SLIM LIGHT SERIES MODEL #: 390440-3546 LSI Test Report 26053
Plane1 - (45 - 225)
Horizontal2 - (2.5) Vertical
Plane1 - (45 - 225)
Horizontal2 - (2.5) Vertical
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 107
www.ldpi-inc.com
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 1.04 1.04 1.04 1.04 1.01 1.01 1.01 1.01 .97 .97 .97 .93 .93 .93 .89 .89 .89 .871 .95 .91 .87 .84 .93 .89 .86 .82 .85 .82 .80 .82 .80 .77 .79 .77 .75 .73 2 .86 .79 .73 .68 .84 .77 .72 .67 .74 .70 .66 .71 .68 .64 .69 .66 .63 .61 3 .78 .69 .62 .56 .76 .68 .61 .56 .65 .60 .55 .63 .58 .54 .61 .56 .53 .51 4 .72 .61 .53 .47 .70 .60 .53 .47 .58 .51 .46 .56 .50 .46 .54 .49 .45 .43 5 .66 .54 .46 .41 .64 .53 .46 .40 .52 .45 .40 .50 .44 .39 .48 .43 .39 .37 6 .61 .49 .41 .35 .59 .48 .40 .35 .46 .40 .35 .45 .39 .34 .43 .38 .34 .32 7 .56 .44 .36 .31 .54 .43 .36 .31 .42 .35 .31 .41 .35 .30 .40 .34 .30 .28 8 .52 .40 .33 .27 .51 .39 .32 .27 .38 .32 .27 .37 .31 .27 .36 .31 .27 .25 9 .49 .37 .29 .24 .47 .36 .29 .24 .35 .29 .24 .34 .28 .24 .33 .28 .24 .22 10 .45 .34 .27 .22 .44 .33 .27 .22 .32 .26 .22 .32 .26 .22 .31 .25 .22 .20
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 4428.87 22.1 25.4 0-40 7553.29 37.8 43.3 0-60 13943.55 69.7 80 0-90 17431.37 87.2 100 90-120 0 0 0 90-130 0 0 0 90-150 0 0 0 90-180 0 0 0 0-180 17431.37 87.2 100
FABRICATED METAL HOUSING WITH WHITE PAINTED GENERAL INTERIOR FINISH FORMED METAL REFLECTOR WITH SPECULAR FILM FINISH, CLEAR FLAT TEXTURED GLASS LENS IN WHITE PAINTED FABRICATED METAL DOOR FRAMEFOUR 54-WATT T-5 FP54/835/HO LINEAR FLUORESCENTSSURFACETotal Luminaire Efficiency = 87.2%Spacing(0-180) 1.26(90-270) 1.66
400T/THO SERIES MODEL #: 390440THO-3265 ITL Test Report 48511
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .91 .91 .91 .91 .89 .89 .89 .89 .85 .85 .85 .81 .81 .81 .78 .78 .78 .76 1 .83 .79 .76 .73 .81 .78 .75 .72 .74 .72 .70 .71 .69 .68 .69 .67 .66 .64 2 .75 .69 .64 .60 .73 .68 .63 .59 .65 .61 .57 .62 .59 .56 .60 .57 .55 .53 3 .69 .61 .54 .49 .67 .59 .54 .49 .57 .52 .48 .55 .51 .47 .53 .49 .46 .45 4 .63 .54 .47 .42 .61 .53 .46 .41 .51 .45 .41 .49 .44 .40 .47 .43 .40 .38 5 .58 .48 .41 .36 .56 .47 .40 .35 .45 .39 .35 .44 .39 .35 .42 .38 .34 .33 6 .53 .43 .36 .31 .52 .42 .36 .31 .41 .35 .31 .39 .34 .30 .38 .34 .30 .28 7 .49 .39 .32 .27 .48 .38 .32 .27 .37 .31 .27 .36 .31 .27 .35 .30 .27 .25 8 .46 .35 .29 .24 .44 .35 .28 .24 .34 .28 .24 .33 .28 .24 .32 .27 .24 .22 9 .43 .32 .26 .22 .42 .32 .26 .22 .31 .25 .22 .30 .25 .21 .29 .25 .21 .2010 .40 .30 .24 .20 .39 .29 .24 .20 .29 .23 .19 .28 .23 .19 .27 .23 .19 .18
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 2308.73 19.9 26.1 0-40 3861.97 33.3 43.7 0-60 7058.68 60.9 79.9 0-90 8831.04 76.1 100 90-120 0 0 0 90-130 0 0 0 90-150 0 0 0 90-180 0 0 0 0-180 8831.04 76.1 100
FABRICATED METAL HOUSING WHITE PAINTED INTERIOR FINISHTWO WHITE PAINTED FORMED METAL SIDE REFLECTORSCLEAR FLAT TEXTURED GLASS LENS IN WHITE PAINTED FABRICATED METAL DOOR FRAMEFOUR 28-WATT T-5 FP28W/835 LINEAR FLUORESCENTS.SURFACETotal Luminaire Efficiency = 76.1%Spacing(0-180) 1.28(90-270) 1.42
ITL Test Report 48513440T/THO SERIES MODEL #: 390440-3546
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .72 .72 .72 .72 .70 .70 .70 .70 .66 .66 .66 .62 .62 .62 .59 .59 .59 .57 1 .64 .60 .57 .54 .62 .59 .56 .53 .55 .53 .51 .52 .50 .48 .49 .48 .46 .45 2 .57 .52 .47 .43 .55 .50 .46 .42 .47 .43 .40 .45 .41 .39 .42 .40 .37 .36 3 .52 .45 .39 .35 .50 .43 .38 .34 .41 .36 .33 .39 .35 .32 .37 .33 .31 .29 4 .47 .39 .33 .29 .45 .38 .32 .28 .36 .31 .27 .34 .30 .27 .32 .29 .26 .24 5 .43 .34 .29 .24 .41 .34 .28 .24 .32 .27 .23 .30 .26 .23 .29 .25 .22 .20 6 .40 .31 .25 .21 .38 .30 .24 .20 .28 .24 .20 .27 .23 .19 .26 .22 .19 .17 7 .36 .28 .22 .18 .35 .27 .22 .18 .26 .21 .17 .24 .20 .17 .23 .19 .17 .15 8 .34 .25 .20 .16 .33 .24 .19 .16 .23 .19 .15 .22 .18 .15 .21 .17 .15 .13 9 .31 .23 .18 .14 .30 .22 .17 .14 .21 .17 .14 .20 .16 .13 .19 .16 .13 .12 10 .29 .21 .16 .12 .28 .20 .16 .12 .20 .15 .12 .19 .15 .12 .18 .14 .12 .10
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 978.75 10.9 17.8 0-40 1756.17 19.5 31.9 0-60 3556.73 39.5 64.7 0-90 5156.05 57.3 93.8 90-120 325.95 3.6 5.9 90-130 340.83 3.8 6.2 90-150 342.51 3.8 6.2 90-180 342.52 3.8 6.2 0-180 5498.56 61.1 100
WITH SPECULAR REFLECTOR AND RIBBED ACRyLIC WRAP LENSTWO PHILIPS 54 WATT T5HO LAMPSF54T5/841HO. LUMEN RATING = 4500 LMS.Total Luminaire Efficiency = 61.1%Spacing(0-180) 1.24(90-270) 2.06
376 SERIES MODEL #: 376-T5HO-2L-4-UNV-A-B LSI Test Report 21562
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012108
www.ldpi-inc.com
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .77 .77 .77 .77 .74 .74 .74 .74 .70 .70 .70 .65 .65 .65 .61 .61 .61 .60 1 .68 .64 .61 .58 .66 .62 .59 .56 .58 .56 .53 .55 .53 .51 .51 .50 .48 .46 2 .61 .55 .50 .46 .59 .54 .49 .45 .50 .46 .43 .47 .44 .41 .44 .42 .39 .37 3 .56 .48 .42 .38 .53 .47 .41 .37 .44 .39 .35 .41 .37 .34 .39 .35 .33 .31 4 .51 .42 .36 .31 .49 .41 .35 .31 .39 .34 .30 .36 .32 .29 .34 .31 .28 .26 5 .47 .38 .31 .27 .45 .36 .31 .26 .34 .29 .25 .32 .28 .25 .31 .27 .24 .22 6 .43 .34 .28 .23 .41 .33 .27 .23 .31 .26 .22 .29 .25 .21 .28 .24 .21 .19 7 .40 .30 .24 .20 .38 .30 .24 .20 .28 .23 .19 .27 .22 .19 .25 .21 .18 .17 8 .37 .28 .22 .18 .35 .27 .21 .18 .26 .21 .17 .24 .20 .17 .23 .19 .16 .15 9 .34 .25 .20 .16 .33 .25 .19 .16 .23 .19 .15 .22 .18 .15 .21 .17 .15 .13 10 .32 .23 .18 .14 .31 .23 .18 .14 .22 .17 .14 .21 .16 .13 .20 .16 .13 .12
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 765.65 13 19.8 0-40 1316.65 22.3 34.1 0-60 2454.49 41.6 63.5 0-90 3516.16 59.6 91 90-120 335.24 5.7 8.7 90-130 348.55 5.9 9 90-150 349.58 5.9 9 90-180 349.58 5.9 9 0-180 3865.74 65.5 100
WITH WHITE INTERIOR AND RIBBED PLASTIC WRAP LENSTWO PHILIPS 32 WATT T8 LAMPSF32T8/TL841. LUMEN RATING = 2950 LMS.Total Luminaire Efficiency = 65.5%Spacing(0-180) 1.26(90-270) 1.68
376 SERIES MODEL #: 376-T8-2L-4-UNV-PR LSI Test Report 20711
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
376 SERIES MODEL #: 376-T5HO-2L-4-UNV-PD-HB LSI Test Report 21561
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .69 .69 .69 .69 .67 .67 .67 .67 .63 .63 .63 .60 .60 .60 .57 .57 .57 .55 1 .61 .58 .54 .52 .59 .56 .53 .50 .53 .50 .48 .50 .48 .46 .47 .46 .44 .43 2 .55 .49 .44 .40 .53 .48 .43 .40 .45 .41 .38 .42 .39 .37 .40 .38 .35 .34 3 .49 .42 .37 .33 .48 .41 .36 .32 .39 .35 .31 .37 .33 .30 .35 .32 .29 .28 4 .45 .37 .31 .27 .43 .36 .31 .27 .34 .29 .26 .32 .28 .25 .31 .27 .24 .23 5 .41 .33 .27 .23 .40 .32 .27 .22 .30 .26 .22 .29 .25 .21 .27 .24 .21 .19 6 .38 .29 .24 .20 .36 .29 .23 .19 .27 .22 .19 .26 .22 .18 .24 .21 .18 .17 7 .35 .26 .21 .17 .34 .26 .21 .17 .24 .20 .16 .23 .19 .16 .22 .19 .16 .14 8 .32 .24 .19 .15 .31 .23 .18 .15 .22 .18 .15 .21 .17 .14 .20 .17 .14 .13 9 .30 .22 .17 .13 .29 .21 .17 .13 .20 .16 .13 .20 .16 .13 .19 .15 .12 .11 10 .28 .20 .15 .12 .27 .20 .15 .12 .19 .15 .12 .18 .14 .11 .17 .14 .11 .10
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 973.59 10.8 18.5 0-40 1664.8 18.5 31.6 0-60 3308.25 36.8 62.8 0-90 4961.47 55.1 94.1 90-120 263.69 2.9 5 90-130 293.29 3.3 5.6 90-150 308.6 3.4 5.6 90-180 308.62 3.4 5.9 0-180 5270.1 58.6 100
WITH SPECULAR REFLECTOR AND DIMPLED POLyCARBONATE WRAP LENSTWO PHILIPS 54 WATT T5 LAMPSF54T5/841HO. LUMEN RATING = 4500 LMS.ONE ADVANCE ICN-2S54 BALLAST OPERATING AT 120 VAC AND 96 WATTSTotal Luminaire Efficiency = 58.6%Spacing(0-180) 1.28(90-270) 1.74
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .86 .86 .86 .86 .83 .83 .83 .83 .78 .78 .78 .73 .73 .73 .69 .69 .69 .671 .76 .72 .68 .64 .73 .69 .66 .63 .65 .62 .60 .61 .59 .57 .58 .56 .54 .522 .68 .61 .55 .51 .66 .59 .54 .49 .56 .51 .47 .52 .49 .45 .49 .46 .43 .413 .62 .53 .46 .41 .59 .51 .45 .40 .48 .43 .39 .45 .41 .37 .43 .39 .36 .344 .56 .47 .40 .34 .54 .45 .39 .34 .43 .37 .32 .40 .35 .31 .38 .34 .30 .285 .52 .41 .34 .29 .49 .40 .34 .29 .38 .32 .28 .36 .31 .27 .34 .29 .26 .246 .47 .37 .30 .25 .46 .36 .29 .25 .34 .28 .24 .32 .27 .23 .30 .26 .23 .217 .44 .33 .27 .22 .42 .33 .26 .22 .31 .25 .21 .29 .24 .20 .28 .23 .20 .188 .41 .30 .24 .19 .39 .30 .23 .19 .28 .23 .19 .27 .22 .18 .25 .21 .18 .169 .38 .28 .22 .17 .37 .27 .21 .17 .26 .20 .17 .25 .20 .16 .23 .19 .16 .1410 .36 .26 .20 .16 .34 .25 .19 .15 .24 .19 .15 .23 .18 .15 .22 .17 .14 .13
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 850.17 14.4 19.7 0-40 1405.7 23.8 32.5 0-60 2645.7 44.8 61.2 0-90 3965.45 67.2 91.7 90-120 316.17 5.4 7.3 90-130 343.37 5.8 7.9 90-150 356.72 6 7.9 90-180 356.81 6 8.3 0-180 4322.26 73.3 100
WITH WHITE INTERIOR AND PRISMATIC PLASTIC WRAP LENSTWO PHILIPS 32 WATT T8 LAMPSF32T8/TL841. LUMEN RATING = 2950 LMS.Total Luminaire Efficiency = 73.3%Spacing(0-180) 1.22(90-270) 1.36
376 SERIES MODEL #: 376-T8-2L-4-UNV-PD LSI Test Report 20712
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 109
www.ldpi-inc.com
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .76 .76 .76 .76 .74 .74 .74 .74 .69 .69 .69 .65 .65 .65 .62 .62 .62 .60 1 .68 .64 .61 .58 .66 .62 .59 .57 .59 .56 .54 .55 .53 .51 .52 .51 .49 .47 2 .61 .55 .50 .46 .59 .53 .49 .45 .50 .47 .43 .47 .44 .42 .45 .42 .40 .38 3 .55 .48 .42 .38 .53 .47 .41 .37 .44 .39 .36 .41 .38 .34 .39 .36 .33 .32 4 .50 .42 .36 .31 .49 .41 .35 .31 .39 .34 .30 .37 .32 .29 .35 .31 .28 .27 5 .46 .38 .31 .27 .45 .36 .31 .26 .35 .30 .26 .33 .28 .25 .31 .27 .24 .23 6 .43 .34 .28 .23 .41 .33 .27 .23 .31 .26 .22 .30 .25 .22 .28 .24 .21 .20 7 .40 .30 .25 .20 .38 .30 .24 .20 .28 .23 .20 .27 .23 .19 .26 .22 .19 .17 8 .37 .28 .22 .18 .35 .27 .22 .18 .26 .21 .18 .25 .20 .17 .24 .20 .17 .15 9 .34 .25 .20 .16 .33 .25 .20 .16 .24 .19 .16 .23 .18 .15 .22 .18 .15 .14 10 .32 .23 .18 .15 .31 .23 .18 .15 .22 .17 .14 .21 .17 .14 .20 .16 .14 .13
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 1237.94 14 21.6 0-40 2027.49 22.9 35.4 0-60 3712.58 42 64.9 0-90 5313.44 60 92.9 90-120 353.7 4 6.2 90-130 389.93 4.4 6.8 90-150 407.27 4.6 6.8 90-180 407.33 4.6 7.1 0-180 5720.77 64.6 100
WITH WHITE INTERIOR AND PRISMATIC PLASTIC WRAP LENSTHREE PHILIPS 32 WATT T8 LAMPSF32T8/TL841. LUMEN RATING = 2950 LMS.Total Luminaire Efficiency = 64.6%Spacing(0-180) 1.22(90-270) 1.28
376 SERIES MODEL #: 376-T8-3L-4-UNV-PD LSI Test Report 20714
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .70 .70 .70 .70 .68 .68 .68 .68 .64 .64 .64 .60 .60 .60 .57 .57 .57 .55 1 .63 .60 .57 .54 .61 .58 .55 .53 .55 .52 .50 .51 .50 .48 .48 .47 .46 .442 .57 .52 .47 .43 .55 .50 .46 .43 .47 .44 .41 .44 .42 .39 .42 .40 .38 .36 3 .52 .45 .40 .36 .50 .44 .39 .35 .41 .37 .34 .39 .36 .33 .37 .34 .32 .30 4 .47 .40 .34 .30 .46 .39 .34 .30 .37 .32 .29 .35 .31 .28 .33 .30 .27 .25 5 .43 .35 .30 .26 .42 .35 .29 .25 .33 .28 .25 .31 .27 .24 .29 .26 .23 .22 6 .40 .32 .26 .22 .39 .31 .26 .22 .29 .25 .22 .28 .24 .21 .27 .23 .20 .19 7 .37 .29 .23 .20 .36 .28 .23 .19 .27 .22 .19 .25 .21 .18 .24 .21 .18 .17 8 .35 .26 .21 .17 .33 .26 .21 .17 .24 .20 .17 .23 .19 .16 .22 .19 .16 .15 9 .32 .24 .19 .16 .31 .23 .19 .15 .22 .18 .15 .21 .18 .15 .21 .17 .14 .13 10 .30 .22 .17 .14 .29 .22 .17 .14 .21 .17 .14 .20 .16 .13 .19 .16 .13 .12
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 1177.63 13.3 22.2 0-40 1991.52 22.5 37.5 0-60 3578.1 40.4 67.4 0-90 4905.96 55.4 92.4 90-120 384.66 4.3 7.2 90-130 402.84 4.6 7.6 90-150 404.67 4.6 7.6 90-180 404.67 4.6 7.6 0-180 5310.63 60 100
WITH WHITE INTERIOR AND RIBBED PLASTIC WRAP LENSTHREE PHILIPS 32 WATT T8 LAMPSF32T8/TL841. LUMEN RATING = 2950 LMS.Total Luminaire Efficiency = 60%Spacing(0-180) 1.24(90-270) 1.54
376 SERIES MODEL #: 376-T8-3L-4-UNV-PR LSI Test Report 20713
376 SERIES MODEL #: 376-T8-4L-8-UNV-A LSI Test Report 20715
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .78 .78 .78 .78 .75 .75 .75 .75 .71 .71 .71 .67 .67 .67 .63 .63 .63 .61 1 .69 .65 .62 .59 .67 .63 .60 .57 .59 .57 .54 .56 .54 .52 .53 .51 .49 .48 2 .62 .56 .51 .46 .60 .54 .50 .46 .51 .47 .44 .48 .45 .42 .45 .42 .40 .38 3 .56 .49 .43 .38 .54 .47 .42 .37 .44 .40 .36 .42 .38 .34 .39 .36 .33 .31 4 .51 .43 .36 .32 .49 .41 .36 .31 .39 .34 .30 .37 .32 .29 .35 .31 .28 .26 5 .47 .38 .31 .27 .45 .37 .31 .26 .35 .30 .26 .33 .28 .25 .31 .27 .24 .22 6 .43 .34 .28 .23 .42 .33 .27 .23 .31 .26 .22 .30 .25 .22 .28 .24 .21 .19 7 .40 .31 .24 .20 .38 .30 .24 .20 .28 .23 .19 .27 .22 .19 .25 .21 .18 .17 8 .37 .28 .22 .18 .36 .27 .21 .18 .26 .21 .17 .24 .20 .17 .23 .19 .16 .15 9 .35 .25 .20 .16 .33 .25 .19 .16 .24 .19 .15 .22 .18 .15 .21 .17 .15 .13 10 .32 .23 .18 .14 .31 .23 .18 .14 .22 .17 .14 .21 .16 .13 .20 .16 .13 .12
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 1530.28 13 19.6 0-40 2609.93 22.1 33.4 0-60 4987.24 42.3 63.7 0-90 7197.58 61 92 90-120 601.09 5.1 7.7 90-130 623.62 5.3 8 90-150 625.64 5.3 8 90-180 625.64 5.3 8 0-180 7823.22 66.3 100
WITH WHITE INTERIOR AND PRISMATIC PLASTIC WRAP LENSFOUR PHILIPS 32 WATT T8 LAMPSF32T8/TL841. LUMEN RATING = 2950 LMS.Total Luminaire Efficiency = 66.3%Spacing(0-180) 1.24(90-270) 1.66
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012110
www.ldpi-inc.com
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
1183
2366
3548
4731
1
2
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 1.09 1.09 1.09 1.09 1.06 1.06 1.06 1.06 1.01 .101 1.01 .95 .95 .95 .91 .91 .91 .881 .97 .92 .87 .82 .94 .89 .85 .81 .84 .81 .77 .80 .77 .74 .76 .73 .71 .692 .87 .79 .71 .65 .84 .76 .70 .64 .72 .67 .62 .69 .64 .60 .65 .61 .58 .553 .79 .68 .60 .53 .76 .66 .58 .52 .63 .56 .51 .60 .54 .49 .57 .52 .48 .454 .72 .60 .51 .44 .69 .58 .50 .43 .55 .48 .42 .53 .46 .41 .50 .45 .40 .385 .66 53 .44 .37 .64 .52 .43 .37 .49 .42 .36 .47 .40 .35 .45 .39 .35 .326 .61 .48 .39 .32 .59 .46 .38 .32 .44 .37 .31 .42 .36 .31 .40 .35 .30 .287 .56 .43 .34 .28 .54 .42 .34 .28 .40 .33 .27 .38 .32 .27 .37 .31 .26 .248 .52 .39 .31 .25 .50 .38 .30 .25 .37 .29 .24 .35 .29 .24 .34 .28 .24 .229 .49 .36 .28 .22 .47 .35 .27 .22 .34 .27 .22 .32 .26 .21 .31 .25 .21 .1910 .46 .33 .25 .20 .44 .32 .25 .20 .31 .24 .20 .30 .24 .19 .29 .23 .19 .17
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 1888.1 9.6 10.430-60 4023.7 20.5 22.160-80 2159.5 11.0 11.980-90 603.1 3.1 3.390-100 488.0 2.5 2.7100-180 350.0 1.8 1.9
Plane1 - (90 - 270)
Horizontal2 - (15) Vertical
ENCLOSED & GASKETED LUMINAIREWHITE REFLECTORCLEAR ACRyLIC DROP LENSFOUR 54W T5HO LAMPSLUMEN RATING = 4900 LMSTotal Luminaire Efficiency = 92.7%Luminaire Efficacy Rating (LER) 80Spacing(0-Deg) 1.28(90-Deg) 1.50
379 SERIES MODEL #: 379-T5HO-4L-White Test Report 14140.0
376 SERIES MODEL #: 376-T8-6L-8-UNV-A LSI Test Report 20716
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .70 .70 .70 .70 .68 .68 .68 .68 .64 .64 .64 .60 .60 .60 .57 .57 .57 .55 1 .63 .59 .56 .54 .61 .58 .55 .52 .54 .52 .50 .51 .49 .48 .48 .47 .45 .44 2 .57 .51 .47 .43 .55 .50 .46 .42 .47 .44 .41 .44 .41 .39 .42 .40 .38 .36 3 .52 .45 .40 .36 .50 .44 .39 .35 .41 .37 .34 .39 .35 .33 .37 .34 .31 .30 4 .47 .40 .34 .30 .45 .38 .33 .29 .36 .32 .29 .34 .31 .28 .33 .29 .27 .25 5 .43 .35 .30 .26 .42 .34 .29 .25 .33 .28 .25 .31 .27 .24 .29 .26 .23 .22 6 .40 .32 .26 .22 .38 .31 .26 .22 .29 .25 .21 .28 .24 .21 .27 .23 .20 .19 7 .37 .29 .23 .20 .36 .28 .23 .19 .27 .22 .19 .25 .21 .18 .24 .21 .18 .17 8 .34 .26 .21 .17 .33 .25 .21 .17 .24 .20 .17 .23 .19 .16 .22 .19 .16 .15 9 .32 .24 .19 .16 .31 .23 .19 .15 .22 .18 .15 .21 .18 .15 .20 .17 .14 .13 10 .30 .22 .17 .14 .29 .22 .17 .14 .21 .16 .14 .20 .16 .13 .19 .16 .13 .12
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 2348.68 13.3 22.3 0-40 3971.57 22.4 37.7 0-60 7131.68 40.3 67.6 0-90 9762.86 55.2 92.6 90-120 746.79 4.2 7.1 90-130 779.38 4.4 7.4 90-150 781.86 4.4 7.4 90-180 781.86 4.4 7.4 0-180 10544.72 59.6 100
WITH WHITE INTERIOR AND PRISMATIC PLASTIC WRAP LENSSIX PHILIPS 32 WATT T8 LAMPSF32T8/TL841. LUMEN RATING = 2950 LMS.Total Luminaire Efficiency = 59.6%Spacing(0-180) 1.24(90-270) 1.54
1654
3307
4961
6614
1
2
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 1.10 1.10 1.10 1.10 1.07 1.07 1.07 1.07 1.01 1.01 1.01 .96 .96 .96 .91 .91 .91 .891 .99 .95 .90 .86 .96 .92 .88 .85 .87 .84 .81 .83 .80 .78 .79 .77 .75 .732 .90 .82 .76 .70 .87 .80 .74 .69 .76 .71 .67 .73 .68 .65 .69 .66 .63 .613 .83 .73 .65 .59 .80 .71 .64 .58 .67 .61 .56 .64 .59 .55 .61 .57 .53 .514 .76 .64 .56 .50 .73 .63 .55 .49 .60 .54 .48 .57 .52 .47 .55 .50 .46 .445 .70 .58 .49 .43 .68 .56 .49 .43 .54 .47 .42 .52 .46 .41 .50 45 .40. .386 .65 .52 .44 .38 .63 .51 .43 .38 .49 .42 .37 .47 .41 .36 .45 .40 .36 .347 .60 .47 .39 .34 .58 .47 .39 .33 .45 .38 .33 .43 .37 .32 .41 .36 .32 .308 .56 .43 .36 .30 .54 .43 .35 .30 .41 .34 .30 .40 .34 .29 .38 .33 .29 .279 .52 .40 .32 .27 .51 .39 .32 .27 .38 .31 .27 .37 .31 .26 .35 .30 .26 .2410 .49 .37 .30 .25 .48 .36 .29 .25 .35 .29 .24 .34 .28 .24 .33 .28 .24 .22
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 2551.2 13.0 14.030-60 4136.7 21.1 22.760-80 1633.3 8.3 8.980-90 429.0 2.2 2.490-100 392 0 2 0 2.1100-180 63.2 1.9 2.0
Plane1 -(67.5 - 247.5)
Horizontal2 - (10) Vertical
ENCLOSED & GASKETED LUMINAIRESPECULAR REFLECTORCLEAR ACRyLIC DROP LENSFOUR 54W T5HO LAMPSLUMEN RATING = 4900 LMSTotal Luminaire Efficiency = 93.0%Luminaire Efficacy Rating (LER) 81Spacing(0-Deg) 1.25(90-Deg) 1.18
379 SERIES MODEL #: 379-T5HO-4L-HB Test Report 14139.0
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 111
www.ldpi-inc.com
957
1914
2870
3827
1
2
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .97 .97 .97 .97 .94 .94 .94 .94 .89 .89 .89 .84 .84 .84 .79 .79 .79 .771 .87 .83 .79 .76 .85 .81 .77 .74 .77 .74 .71 .73 .70 .68 .69 .67 .65 .632 .79 .72 .67 .62 .77 .71 .65 .61 .67. 62 .59 .63 .60 .57 .60 .57 .55 .533 .73 .64 .57 .52 .70 .62 .56 .51 .59 .54 .49 .56 .52 .48 .53 .50 .47 .454 .67 .57 .49 .44 .64 .55 .49 .43 .53 .47 .42 .50 .45 .41 .48 .44 .40 .385 .61 .51 .44 .38 .59 .50 .43 .38 .47 .41 .37 .45 .40 .36 .43 .39 .35 .336 .57 .46 .39 .33 .55 .45 .38 .33 .43 .37 .33 .41 .36 .32 .39 .35 .31 .297 .53 .42 .35 .30 .51 .41 .34 .30 .39 .33 .29 .38 .32 .28 .36 .32 .28 .268 .49 .38 .31 .27 .48 .38 .31 .27 .36 .30 .26 .35 .29 .26 .33 .29 .25 .249 .46 .35 .29 .24 .45 .35 .28 .24 .33 .28 .24 .32 .27 .23 .31 .26 .23 .2110 .43 .33 .26 .22 .42 .32 .26 .22 .31 .25 .22 .30 .25 .21 .29 .24 .21 .20
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 1372.9 11.6 14.230-60 2095.0 17.8 21.660-80 905.2 7.7 9.380-90 196.2 1.7 2.090-100 246.2 2.1 2.5100-180 301.9 2.6 3.1
Plane1 - (67.5 - 247.5)
Horizontal2 - (15) Vertical
ENCLOSED & GASKETED LUMINAIRESPECULAR REFLECTORCLEAR ACRyLIC DROP LENSFOUR 32W T8 LAMPSLUMEN RATING = 2950 LMSTotal Luminaire Efficiency = 82.0%Luminaire Efficacy Rating (LER) 97 Spacing(0-Deg) 1.24(90-Deg) 1.05
379 SERIES MODEL #: 379-T8-4L-HB Test Report 14135.0
640
1280
1920
2560
1
2
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .95 .95 .95 .95 .92 .92 .92 .92 .87 .87 .87 .82 .82 .82 .78 .78. 78 .761 .85 .81 .77 .73 .83 .79 .75 .71 .74 .71 .68 .70 .68 .65 .66 .64 .62 .602 .77 .70 .63 .58 .74 .68 .62 .57 .64 .59 .55 .60 .56 .53 .57 .54 .51 .493 .70 .60 .53 .48 .67 .59 .52 .47 .56 .50 .45 .53 .48 .44 .50 .46 .42 .404 .64 .53 .46 .40 .61 .52 .45 .39 .49 .43 .38 .46 .41 .37 .44 .40 .36 .345 .58 .47 .39 .34 .56 .46 .39 .33 .44 .37 .33 .41 .36 .32 .39 .35 .31 .296 .54 .42 .35 .29 .52 .41 .34 .29 .39 .33 .28 .37 .32 .28 .36 .31 .27 .257 .50 .38 .31 .26 .48 .37 .30 .25 .36 .29 .25 .34 .28 .24 .32 .27 .24 .228 .46 .35 .28 .23 .44 .34 .27 .22 .32 .26 .22 .31 .26 .22 .30 .25 .21 .199 .43 .32 .25 .20 .42 .31 .25 .20 .30 .24 .20 .28 .23 .19 .27 .22 .19 .1710 .40 .29 .23 .18 .39 .29 .22 .18 .27 .22 .18 .26 .21 .17 .25 .21 .17 .16
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 1020.4 8.6 10.730-60 2168.1 18.4 22.760-80 1051.4 8.9 11.080-90 246.3 2.1 2.690-100 277.0 2.3 2.9100-180 322.4 2.7 3.4
Plane1 - (90 - 270)
Horizontal2 - (20) Vertical
ENCLOSED & GASKETED LUMINAIREWHITE REFLECTORCLEAR ACRyLIC DROP LENSFOUR 32W T8 LAMPSLUMEN RATING = 2950 LMSTotal Luminaire Efficiency = 81.1%Luminaire Efficacy Rating (LER) 96Spacing(0-Deg) 1.26(90-Deg) 1.48
379 SERIES MODEL #: 379-T8-4L-White Test Report 14136.0
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
2115
4230
6345
8460
1
2
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 1.08 1.08 1.08 1.08 1.05 1.05 1.05 1.05 .99 .99 .99 .94 .94 .94 .90 .90 .90 .871 .97 .92 .88 .84 .94 .90 .86 .82 .85 .82 .79 .81 .78 .76 .77 .75 .73 .712 .88 .80 .73 .68 .85 .78 .72 .67 .74 .69 .64 .70 .66 .62 .67 .64 .60 .583 .80 .70 .62 .56 .77 .68 .61 .55 .65 .59 .54 .62 .57 .52 .59 .55 .51 .494 .73 .62 .53 .47 .71 .60 .53 .47 .58 .51 .46 .55 .49 .44 .52 .48 .43 .415 .67 .55 .47 .40 .65 .54 .46 .40 .51 .45 .39 .49 .43 .38 .47 .42 .38 .366 .62 .50 .41 .35 .60 .48 .41 .35 .46 .39 .34 .44 .38 .34 .43 .37 .33 .317 .57 .45 .37 .31 .56 .44 .36 .31 .42 .35 .30 .41 .34 .30 .39 .33 .29 .278 .53 .41 .33 .28 .52 .40 .33 .27 .39 .32 .27 .37 .31 .27 .36 .30 .26 .249 .50 .38 .30 .25 .48 .37 .30 .25 .35 .29 .24 .34 .28 .24 .33 .28 .24 .2210 .47 .35 .27 .22 .45 .34 .27 .22 .33 .26 .22 .32 .26 .22 .31 .25 .21 .20
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 3311.3 11.3 12.330-60 6273.8 21.3 23.360-80 2692.6 9.2 10.080-90 593.6 2.0 2.290-100 507.0 1.7 1.9100-180 619.3 2.1 2.3
Plane1 - (90 - 270)
Horizontal2 - (15) Vertical
ENCLOSED & GASKETED LUMINAIRESPECULAR REFLECTORCLEAR ACRyLIC DROP LENSSIX 54W T5HO LAMPSLUMEN RATING = 4900 LMSTotal Luminaire Efficiency = 91.3%Luminaire Efficacy Rating (LER) 82Spacing(0-Deg) 1.24(90-Deg) 1.36
379 SERIES MODEL #: 379-T5HO-6L-HB Test Report 14141.0
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012112
www.ldpi-inc.com
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
1007
2014
3020
4027
2
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .91 .91 .91 .91 .89 .89 .89 .89 .84 .84 .84 .79 .79 .79 .75 .75 .75 .731 .82 .78 .74 .71 .80 .76 .73 .70 .72 .69 .67 .68 .66 .64 .65 .63 .61 .592 .74 .67 .62 .57 .72 .66 .60 .56 .62 .58 .54 .59 .55 .52 .59 .53 .51 .493 .67 .59 .52 .47 .65 .57 .51 .46 .54 .49 .45 .52 .47 .44 .49 .45 .42 .404 .62 .52 .45 .39 .59 .51 .44 .39 .48 .42 .38 .46 .41 .37 .44 .39 .36 .345 .56 .46 .39 .34 .54 .45 .38 .33 .43 .37 .32 .41 .36 .32 .39 .35 .31 .296 .52 .41 .34 .29 .50 .40 .34 .29 .39 .33 .28 .37 .32 .28 .35 .31 .27 .257 .48 .37 .30 .26 .47 .37 .30 .25 .35 .29 .25 .34 .28 .24 .32 .28 .24 .228 .45 .34 .27 .23 .43 .33 .27 .22 .32 .26 .22 .31 .26 .22 .30 .25 .21 .209 .42 .31 .25 .20 .40 .31 .24 .20 .29 .24 .20 .28 .23 .20 .27 .23 .19 .1810 .39 .29 .22 .18 .38 .28 .22 .18 .27 .22 .18 .26 .21 .18 .25 .21 .17 .16
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 1585.2 9.0 11.630-60 3220.3 18.2 23.560-80 1417.2 8.0 10.480-90 283.9 1.6 2.190-100 298.8 1.7 2.2100-180 375.1 2.1 2.7
Plane1 - (90 - 270)
Horizontal2 - (15) Vertical
ENCLOSED & GASKETED LUMINAIREWHITE REFLECTORCLEAR ACRyLIC DROP LENSSIX 32W T8 LAMPSLUMEN RATING = 2950 LMSTotal Luminaire Efficiency = 77.3%Luminaire Efficacy Rating (LER) 96Spacing(0-Deg) 1.28(90-Deg) 1.47
379 SERIES MODEL #: 379-T8-6L-White Test Report 14138.0
833
3666
5499
332
1
2
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 1.08 1.08 1.08 1.08 1.05 1.05 1.05 1.05 .99 .99 .99 .94 .94 .94 .89 .89 .89 .871 .96 .91 .87 .83 .93 .89 .85 .81 .84 .81 .77 .80 .77 .74 .76 .73 .71 .692 .87 .78 .71 .65 .84 .76 .70 .64 .72 .67 .62 .69 .64 .60 .65 .61 .58 .563 .79 .68 .60 .53 .76 .66 .59 .53 .63 .56 .51 .60 .54 .50 .57 .52 .48 .464 .72 .60 .51 .45 .69 .58 .50 .44 .55 .48 .43 .53 .47 .42 .50 .45 .41 .395 .66 .53 .44 .38 .63 .52 .44 .38 .49 .42 .37 .47 .41 .36 .45 .39 .35 .336 .60 .48 .39 .33 .58 .46 .38 .32 .44 .37 .32 .42 .36 .31 .41 .35 .31 .297 .56 .43 .35 .29 .54 .42 .34 .28 .40 .33 .28 .38 .32 .27 .37 .31 .27 .258 .52 .39 .31 .25 .50 .38 .31 .25 .37 .30 .25 .35 .29 .24 .34 .28 .24 .229 .48 .36 .28 .23 .47 .35 .28 .23 .34 .27 .22 .32 .26 .22 .31 .26 .22 .2010 .45 .33 .25 .20 .44 .32 .25 .20 .31 .25 .20 .30 .24 .20 .29 .23 .19 .18
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 2905.8 9.9 10.830-60 6153.6 20.9 22.960-80 3060.7 10.4 11.480-90 713.9 2.4 2.790-100 579.5 2.0 2.2100-180 614.6 2.1 2.3
Plane1 - (90 - 270)
Horizontal2 - (15) Vertical
ENCLOSED & GASKETED LUMINAIREWHITE REFLECTORCLEAR ACRyLIC DROP LENSSIX 54W T5HO LAMPSLUMEN RATING = 4900 LMSTotal Luminaire Efficiency = 91.3%Luminaire Efficacy Rating (LER) 82Spacing(0-Deg) 1.286(90-Deg) 1.45
379 SERIES MODEL #: 379-T5HO-6L-White Test Report 14142.0
106
2212
3317
4 23
1
2
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .91 .91 .91 .91 .89 .89 .89 .89 .84 .84 .84 .79 .79 .79 .76 .76 .76 .741 .83 .79 .75 .72 .80 .76 .73 .70 .73 .70 .67 .69 .67 .65 .65 .64 .62 .602 .75 .68 .63 .58 .72 .66 .61 .57 .63 .59 .55 .60 .57 .53 .57 .54 .52 .503 .68 .60 .53 .48 .66 .58 .52 .47 .55 .50 .46 .53 .48 .45 .50 .47 .44 .424 .62 .53 .46 .41 .60 .52 .45 .40 .49 .44 .39 .47 .42 .38 .45 .41 .37 .365 .57 .47 .40 .35 .55 .46 .39 .35 .44 .38 .34 .42 .37 .33 .40 .36 .32 .316 .53 .42 .35 .30 .51 .41 .35 .30 .40 .34 .30 .38 .33 .29 .37 .32 .28 .277 .49 .38 .32 .27 .47 .38 .31 .27 .36 .30 .26 .35 .30 .26 .33 .29 .25 .248 .46 .35 .28 .24 .44 .34 .28 .24 .33 .27 .23 .32 .27 .23 .31 .26 .23 .219 .43 .32 .26 .21 .41 .32 .25 .21 .30 .25 .21 .29 .24 .21 .28 .24 .20 .1910 .40 .30 .24 .19 .39 .29 .23 .19 .28 .23 .19 .27 .22 .19 .26 .22 .19 .17
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 1730.2 9.8 12.630-60 3233.0 18.3 23.660-80 1319.6 7.5 9.680-90 240.1 1.4 1.890-100 273.7 1.5 2.0100-180 368.8 2.1 2.7
Plane1 -(0 - 180)Horizontal
2 - (10) Vertical
ENCLOSED & GASKETED LUMINAIRESPECULAR REFLECTORCLEAR ACRyLIC DROP LENSSIX 32W T8 LAMPSLUMEN RATING = 2950 LMSTotal Luminaire Efficiency = 77.3%Luminaire Efficacy Rating (LER) 97Spacing(0-Deg) 1.27(90-Deg) 1.29
379 SERIES MODEL #: 379-T8-6L-HB Test Report 14137.0
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 113
www.ldpi-inc.com
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .78 .78 .78 .78 .76 .76 .76 .76 .72 .72 .72 .69 .69 .69 .66 .66 .66 .65 1 .70 .66 .63 .60 .68 .65 .62 .59 .62 .60 .57 .59 .57 .56 .57 .55 .54 .52 2 .63 .57 .52 .48 .61 .56 .51 .47 .53 .49 .46 .51 .48 .45 .49 .46 .44 .42 3 .57 .49 .44 .39 .55 .48 .43 .39 .46 .42 .38 .44 .41 .37 .43 .39 .37 .35 4 .52 .43 .37 .33 .50 .43 .37 .32 .41 .36 .32 .39 .35 .31 .38 .34 .31 .29 5 .47 .39 .32 .28 .46 .38 .32 .28 .36 .31 .27 .35 .30 .27 .34 .30 .27 .25 6 .44 .35 .28 .24 .42 .34 .28 .24 .33 .27 .24 .32 .27 .23 .30 .26 .23 .22 7 .40 .31 .25 .21 .39 .31 .25 .21 .30 .24 .21 .29 .24 .21 .28 .24 .20 .19 8 .38 .28 .23 .19 .37 .28 .22 .19 .27 .22 .18 .26 .22 .18 .25 .21 .18 .17 9 .35 .26 .20 .17 .34 .26 .20 .17 .25 .20 .17 .24 .20 .16 .23 .19 .16 .15 10 .33 .24 .19 .15 .32 .24 .18 .15 .23 .18 .15 .22 .18 .15 .22 .18 .15 .14
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 1356.99 15.1 23.2 0-40 2258.04 25.1 38.5 0-60 4196.79 46.6 71.6 0-90 5852.73 65 99.8 90-120 8.86 .1 .2 90-130 8.86 .1 .2 90-150 8.86 .1 .2 90-180 8.86 .1 .2 0-180 5861.6 65.1 100
WHITE REFLECTOR AND CLEAR GLASS TUBE LENSTWO PHILIPS 54 WATT T5 LAMPSF54T5/841/HO/ALTO. LUMEN RATING = 4500 LMS.Total Luminaire Efficiency = 65.1%Spacing(0-180) 1.26(90-270) 1.38
380 SERIES MODEL #: 380-T5HO-2L-4-UNV LSI Test Report 20718
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .87 .87 .87 .87 .85 .85 .85 .85 .82 .82 .82 .78 .78 .78 .75 .75 .75 .73 1 .79 .75 .71 .68 .77 .73 .70 .67 .70 .67 .65 .67 .65 .63 .64 .63 .61 .59 2 .71 .64 .59 .54 .69 .63 .58 .54 .60 .56 .52 .58 .54 .51 .55 .52 .50 .48 3 .64 .56 .49 .44 .62 .55 .49 .44 .52 .47 .43 .50 .46 .42 .48 .45 .41 .40 4 .59 .49 .42 .37 .57 .48 .42 .37 .46 .41 .36 .44 .40 .36 .43 .39 .35 .33 5 .54 .44 .37 .31 .52 .43 .36 .31 .41 .35 .31 .40 .35 .31 .38 .34 .30 .28 6 .49 .39 .32 .27 .48 .38 .32 .27 .37 .31 .27 .36 .31 .27 .34 .30 .26 .25 7 .46 .35 .29 .24 .44 .35 .28 .24 .34 .28 .24 .32 .27 .23 .31 .27 .23 .22 8 .43 .32 .26 .21 .41 .32 .25 .21 .31 .25 .21 .30 .25 .21 .29 .24 .21 .19 9 .40 .29 .23 .19 .39 .29 .23 .19 .28 .23 .19 .27 .22 .19 .26 .22 .19 .1710 .37 .27 .21 .17 .36 .27 .21 .17 .26 .21 .17 .25 .20 .17 .25 .20 .17 .15
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 1009.75 17.1 23.3 0-40 1678.75 28.5 38.7 0-60 3122.56 52.9 72 0-90 4322.28 73.3 99.6 90-120 17.16 .3 .4 90-130 17.16 .3 .4 90-150 17.16 .3 .4 90-180 17.16 .3 .4 0-180 4339.44 73.5 100
WHITE REFLECTOR AND CLEAR GLASS TUBE LENSTWO PHILIPS 32 WATT T8 LAMPSF32T8/TL841. LUMEN RATING = 2950 LMS.Total Luminaire Efficiency = 73.5%Spacing(0-180) 1.26(90-270) 1.38
380 SERIES MODEL #: 380-T8-2L-4-UNV LSI Test Report 20717
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
380 SERIES MODEL #: 380-T5HO-2L-4-UNV-HB LSI Test Report 22800
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .90 .90 .90 .90 .88 .88 .88 .88 .84 .84 .84 .80 .80 .80 .77 .77 .77 .75 1 .82 .78 .74 .71 .79 .76 .73 .70 .73 .70 .68 .70 .67 .65 .67 .65 .63 .62 2 .74 .67 .62 .57 .72 .66 .61 .57 .63 .59 .55 .61 .57 .54 .58 .55 .53 .51 3 .67 .59 .53 .48 .65 .58 .52 .47 .56 .51 .46 .54 .49 .46 .52 .48 .45 .43 4 .62 .53 .46 .41 .60 .52 .45 .40 .50 .44 .40 .48 .43 .39 .46 .42 .39 .37 5 .57 .47 .40 .35 .55 .46 .40 .35 .45 .39 .35 .43 .38 .34 .42 .37 .34 .32 6 .53 .43 .36 .31 .51 .42 .35 .31 .40 .35 .30 .39 .34 .30 .38 .33 .30 .28 7 .49 .39 .32 .27 .48 .38 .32 .27 .37 .31 .27 .36 .31 .27 .35 .30 .27 .25 8 .46 .35 .29 .25 .44 .35 .29 .25 .34 .28 .24 .33 .28 .24 .32 .27 .24 .23 9 .43 .33 .26 .22 .42 .32 .26 .22 .31 .26 .22 .30 .26 .22 .30 .25 .22 .20 10 .40 .30 .24 .20 .39 .30 .24 .20 .29 .24 .20 .28 .23 .20 .28 .23 .20 .19
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 1987.17 22.1 29.2 0-40 3095.9 34.4 45.5 0-60 5096.14 56.6 74.9 0-90 6787.46 75.4 99.8 90-120 12.65 .1 .2 90-130 12.65 .1 .2 90-150 12.65 .1 .2 90-180 12.66 .1 .2 0-180 6800.12 75.6 100
SPECULAR REFLECTORCLEAR GLASS TUBE LENSTWO PHILIPS 54 WATT T5 LAMPSF54T5/841HO. LUMEN RATING = 4500 LMS.Total Luminaire Efficiency = 75.6%Spacing(0-180) 1.22(90-270) 1.10
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012114
www.ldpi-inc.com
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .92 .92 .92 .92 .89 .89 .89 .89 .85 .85 .85 .82 .82 .82 .78 .78 .78 .77 1 .83 .78 .75 .71 .80 .77 .73 .70 .73 .71 .68 .70 .68 .66 .67 .66 .64 .62 2 .74 .67 .62 .57 .72 .66 .60 .56 .63 .58 .55 .60 .57 .53 .58 .55 .52 .50 3 .67 .58 .52 .46 .65 .57 .51 .46 .55 .49 .45 .53 .48 .44 .50 .47 .43 .41 4 .61 .51 .44 .38 .59 .50 .43 .38 .48 .42 .38 .46 .41 .37 .45 .40 .36 .35 5 .56 .46 .38 .33 .54 .45 .38 .32 .43 .37 .32 .41 .36 .32 .40 .35 .31 .30 6 .52 .41 .33 .28 .50 .40 .33 .28 .39 .32 .28 .37 .32 .28 .36 .31 .27 .26 7 .48 .37 .30 .25 .46 .36 .29 .25 .35 .29 .24 .34 .28 .24 .33 .28 .24 .22 8 .44 .33 .27 .22 .43 .33 .26 .22 .32 .26 .22 .31 .25 .22 .30 .25 .21 .20 9 .41 .31 .24 .20 .40 .30 .24 .20 .29 .23 .19 .28 .23 .19 .28 .23 .19 .18 10 .39 .28 .22 .18 .38 .28 .22 .18 .27 .21 .18 .26 .21 .17 .26 .21 .17 .16
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 2081.27 17.6 22.9 0-40 3466.55 29.4 38.1 0-60 6493.18 55 71.50-90 9061.34 76.8 99.7 90-120 25.93 .2 .3 90-130 25.93 .2 .3 90-150 25.93 .2 .3 90-180 25.93 .2 .3 0-180 9087.27 77 100
380-T8-4L-4-UNVWHITE REFLECTOR AND CLEAR GLASS TUBE LENSFOUR PHILIPS 32 WATT T8 LAMPSF32T8/TL841. LUMEN RATING = 2950 LMS.Total Luminaire Efficiency = 77%Spacing(0-180) 1.26(90-270) 1.38
380 SERIES MODEL #: 380-T8-4L-4-UNV LSI Test Report 22802
380 SERIES MODEL #: 380-T5HO-3L-4-UNV-HB LSI Test Report 22801
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .84 .84 .84 .84 .82 .82 .82 .82 .78 .78 .78 .75 .75 .75 .72 .72 .72 .70 1 .76 .72 .69 .66 .74 .71 .68 .65 .68 .65 .63 .65 .63 .61 .62 .61 .59 .58 2 .69 .63 .58 .54 .67 .62 .57 .53 .59 .55 .52 .57 .53 .51 .55 .52 .49 .48 3 .63 .55 .49 .45 .61 .54 .49 .44 .52 .47 .43 .50 .46 .43 .48 .45 .42 .40 4 .58 .49 .43 .38 .56 .48 .42 .38 .46 .41 .37 .45 .40 .37 .43 .39 .36 .34 5 .53 .44 .37 .33 .52 .43 .37 .33 .42 .36 .32 .40 .35 .32 .39 .35 .31 .30 6 .49 .40 .33 .29 .48 .39 .33 .29 .38 .32 .28 .36 .32 .28 .35 .31 .28 .267 .46 .36 .30 .26 .44 .35 .30 .25 .34 .29 .25 .33 .29 .25 .32 .28 .25 .23 8 .43 .33 .27 .23 .41 .33 .27 .23 .32 .26 .23 .31 .26 .23 .30 .26 .22 .21 9 .40 .30 .25 .21 .39 .30 .24 .21 .29 .24 .21 .28 .24 .20 .28 .23 .20 .1910 .37 .28 .23 .19 .36 .28 .22 .19 .27 .22 .19 .26 .22 .19 .26 .22 .19 .17
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 2766.69 20.5 29.2 0-40 4307.35 31.9 45.4 0-60 7148.31 53 75.3 0-90 9478.52 70.2 99.9 90-120 9.41 .1 .1 90-130 9.41 .1 .1 90-150 9.41 .1 .1 90-180 9.41 .1 .1 0-180 9487.93 70.3 100
SPECULAR REFLECTORCLEAR GLASS TUBE LENSTHREE PHILIPS 54 WATT T5 LAMPSF54T5/841HO. LUMEN RATING = 4500 LMS.Total Luminaire Efficiency = 70.3%Spacing(0-180) 1.22(90-270) 1.08
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .91 .91 .91 .91 .89 .89 .89 .89 .85 .85 .85 .81 .81 .81 .78 .78 .78 .77 1 .82 .78 .75 .71 .80 .77 .73 .70 .73 .70 .68 .70 .68 .66 .67 .65 .64 .62 2 .74 .67 .62 .57 .72 .66 .60 .56 .63 .58 .55 .60 .57 .53 .58 .55 .52 .50 3 .67 .58 .52 .46 .65 .57 .51 .46 .55 .49 .45 .53 .48 .44 .50 .47 .43 .41 4 .61 .51 .44 .39 .59 .50 .43 .38 .48 .42 .38 .46 .41 .37 .45 .40 .37 .35 5 .56 .46 .38 .33 .54 .45 .38 .33 .43 .37 .32 .41 .36 .32 .40 .35 .31 .30 6 .52 .41 .34 .28 .50 .40 .33 .28 .39 .32 .28 .37 .32 .28 .36 .31 .27 .26 7 .48 .37 .30 .25 .46 .36 .29 .25 .35 .29 .24 .34 .28 .24 .33 .28 .24 .22 8 .44 .33 .27 .22 .43 .33 .26 .22 .32 .26 .22 .31 .25 .22 .30 .25 .21 .20 9 .41 .31 .24 .20 .40 .30 .24 .20 .29 .23 .19 .28 .23 .19 .28 .23 .19 .18 10 .39 .28 .22 .18 .38 .28 .22 .18 .27 .21 .18 .26 .21 .17 .26 .21 .17 .16
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 1561.37 17.6 23 0-40 2603.74 29.4 38.3 0-60 4888.78 55.2 72 0-90 6770.77 76.5 99.7 90-120 22.55 .3 .3 90-130 22.61 .3 .3 90-150 22.63 .3 .3 90-180 22.63 .3 .3 0-180 6793.4 76.8 100
WHITE REFLECTOR AND CLEAR GLASS TUBE LENSTHREE PHILIPS 32 WATT T8 LAMPSF32T8/TL841. LUMEN RATING = 2950 LMS.Total Luminaire Efficiency = 76.8%Spacing(0-180) 1.26(90-270) 1.40
380 SERIES MODEL #: 380-T8-3L-4-UNV LSI Test Report 22799
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 115
www.ldpi-inc.com
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .72 .72 .72 .72 .67 .67 .67 .67 .58 .58 .58 .50 .50 .50 .42 .42 .42 .391 .62 .57 .53 .49 .57 .53 .49 .45 .45 .42 .39 .37 .35 .33 .31 .29 .27 .24 2 .54 .47 .41 .36 .50 .44 .38 .34 .37 .33 .29 .30 .27 .24 .25 .22 .20 .17 3 .49 .40 .34 .28 .45 .37 .31 .26 .31 .26 .22 .26 .22 .19 .20 .17 .15 .12 4 .44 .35 .28 .23 .40 .32 .26 .21 .27 .22 .18 .22 .18 .15 .17 .14 .12 .09 5 .40 .30 .24 .19 .36 .28 .22 .17 .23 .18 .15 .19 .15 .12 .15 .12 .09 .07 6 .36 .27 .20 .16 .33 .25 .19 .15 .21 .16 .12 .17 .13 .10 .14 .10 .08 .06 7 .34 .24 .18 .13 .31 .22 .16 .12 .19 .14 .10 .15 .11 .08 .12 .09 .07 .05 8 .31 .22 .16 .11 .28 .20 .14 .11 .17 .12 .09 .14 .10 .07 .11 .08 .06 .04 9 .29 .19 .14 .10 .26 .18 .13 .09 .15 .11 .08 .13 .09 .06 .10 .07 .05 .03 10 .27 .18 .12 .9 .25 .16 .11 .08 .14 .10 .07 .12 .08 .06 .09 .06 .04 .03
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 20.79 2.3 3.5 0-40 46.25 5.1 7.8 0-60 137.6 15.3 23.1 0-90 350.28 38.9 58.8 90-120 182.03 20.2 30.6 90-130 216.35 24 36.3 90-150 244.25 27.1 41 90-180 245.14 27.2 41.2 0-180 595.41 66.2 100
VAPOR PROOF - CFL BRACKET/BOXCLEAR LINEAR PRISMATIC GLASS JAR LENS DIE CAST GUARDONE 13 WATT CPFL LAMP. LUMEN RATING = 900 LMS.SIMULATED REPORT FROM TEST WITH 42W LAMPTotal Luminaire Efficiency = 66.2%
387 SERIES MODEL #: 387-CFL13-BB Test Report 20864C
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .73 .73 .73 .73 .68 .68 .68 .68 .59 .59 .59 .50 .50 .50 .42 .42 .42 .38 1 .63 .58 .54 .50 .58 .54 .50 .46 .45 .42 .40 .37 .35 .33 .30 .28 .27 .23 2 .56 .48 .43 .38 .51 .45 .39 .35 .37 .33 .29 .30 .27 .24 .24 .22 .19 .16 3 .50 .41 .35 .29 .45 .38 .32 .27 .31 .27 .23 .26 .22 .19 .20 .17 .15 .12 4 .45 .36 .29 .24 .41 .33 .27 .22 .27 .22 .18 .22 .18 .15 .17 .14 .12 .09 5 .41 .31 .25 .20 .37 .29 .23 .18 .24 .19 .15 .19 .15 .12 .15 .12 .09 .07 6 .37 .28 .21 .16 .34 .25 .19 .15 .21 .16 .13 .17 .13 .10 .13 .10 .08 .06 7 .34 .25 .18 .14 .31 .23 .17 .13 .19 .14 .11 .15 .12 .09 .12 .09 .07 .05 8 .32 .22 .16 .12 .29 .20 .15 .11 .17 .13 .09 .14 .10 .07 .11 .08 .06 .04 9 .29 .20 .14 .10 .27 .19 .13 .10 .15 .11 .08 .13 .09 .06 .10 .07 .05 .03 10 .27 .18 .13 .09 .25 .17 .12 .08 .14 .10 .07 .12 .08 .06 .09 .06 .04 .03
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 21.18 2.4 3.5 0-40 46.47 5.2 7.6 0-60 135.01 15 22.2 0-90 339.22 37.7 55.7 90-120 189.68 21.1 31.2 90-130 230.11 25.6 37.8 90-150 266.69 29.6 43.8 90-180 269.5 29.9 44.3 0-180 608.72 67.6 100
VAPOR PROOF - CFL CEILINGCLEAR LINEAR PRISMATIC GLASS JAR LENS DIE CAST GUARDONE 13 WATT CPFL LAMP. LUMEN RATING = 900 LMS.SIMULATED REPORT FROM TEST WITH 42 WATT LAMPTotal Luminaire Efficiency = 67.6%
387 SERIES MODEL #: 387-CFL13-C Test Report 20865C
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .72 .72 .72 .72 .67 .67 .67 .67 .58 .58 .58 .50 .50 .50 .42 .42 .42 .39 1 .62 .57 .53 .49 .57 .53 .49 .45 .45 .42 .39 .37 .35 .33 .31 .29 .27 .24 2 .54 .47 .41 .36 .50 .44 .38 .34 .37 .33 .29 .30 .27 .24 .25 .22 .20 .17 3 .49 .40 .34 .28 .45 .37 .31 .26 .31 .26 .22 .26 .22 .19 .20 .17 .15 .12 4 .44 .35 .28 .23 .40 .32 .26 .21 .27 .22 .18 .22 .18 .15 .17 .14 .12 .09 5 .40 .30 .24 .19 .36 .28 .22 .17 .23 .18 .15 .19 .15 .12 .15 .12 .09 .07 6 .36 .27 .20 .16 .33 .25 .19 .15 .21 .16 .12 .17 .13 .10 .14 .10 .08 .06 7 .34 .24 .18 .13 .31 .22 .16 .12 .19 .14 .10 .15 .11 .08 .12 .09 .07 .05 8 .31 .22 .16 .11 .28 .20 .14 .11 .17 .12 .09 .14 .10 .07 .11 .08 .06 .04 9 .29 .19 .14 .10 .26 .18 .13 .09 .15 .11 .08 .13 .09 .06 .10 .07 .05 .03 10 .27 .18 .12 .09 .25 .16 .11 .08 .14 .10 .07 .12 .08 .06 .09 .06 .04 .03
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 41.59 2.3 3.5 0-40 92.49 5.1 7.8 0-60 275.2 15.3 23.10-90 700.55 38.9 58.8 90-120 364.03 20.2 30.6 90-130 432.69 24 36.3 90-150 488.48 27.1 41 90-180 490.26 27.2 41.2 0-180 1190.82 66.2 100
VAPOR PROOF - CFL BRACKET/BOXCLEAR LINEAR PRISMATIC GLASS JAR LENSDIE CAST GUARDONE 26 WATT CPFL LAMP. LUMEN RATING = 1800 LMS.SIMULATED REPORT FROM TEST WITH 42 WATT LAMPTotal Luminaire Efficiency = 66.2%
387 SERIES MODEL #: 387-CFL26-BB Test Report 20864B
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012116
www.ldpi-inc.com
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
387 SERIES MODEL #: 387-CFL32-C
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .73 .73 .73 .73 .68 .68 .68 .68 .59 .59 .59 .50 .50 .50 .42 .42 .42 .38 1 .63 .58 .54 .50 .58 .54 .50 .46 .45 .42 .40 .37 .35 .33 .30 .28 .27 .23 2 .56 .48 .43 .38 .51 .45 .39 .35 .37 .33 .29 .30 .27 .24 .24 .22 .19 .16 3 .50 .41 .35 .29 .45 .38 .32 .27 .31 .27 .23 .26 .22 .19 .20 .17 .15 .12 4 .45 .36 .29 .24 .41 .33 .27 .22 .27 .22 .18 .22 .18 .15 .17 .14 .12 .09 5 .41 .31 .25 .20 .37 .29 .23 .18 .24 .19 .15 .19 .15 .12 .15 .12 .09 .07 6 .37 .28 .21 .16 .34 .25 .19 .15 .21 .16 .13 .17 .13 .10 .13 .10 .08 .06 7 .34 .25 .18 .14 .31 .23 .17 .13 .19 .14 .11 .15 .12 .09 .12 .09 .07 .05 8 .32 .22 .16 .12 .29 .20 .15 .11 .17 .13 .09 .14 .10 .07 .11 .08 .06 .04 9 .29 .20 .14 .10 .27 .19 .13 .10 .15 .11 .08 .13 .09 .06 .10 .07 .05 .03 10 .27 .18 .13 .09 .25 .17 .12 .08 .14 .10 .07 .12 .08 .06 .09 .06 .04 .03
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 56.46 2.4 3.5 0-40 123.91 5.2 7.6 0-60 360.01 15 22.2 0-90 904.52 37.7 55.7 90-120 505.91 21.1 31.2 90-130 613.78 25.6 37.8 90-150 711.33 29.6 43.8 90-180 718.89 30 44.3 0-180 1623.41 67.6 100
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
VAPOR PROOF - CFL CEILINGCLEAR LINEAR PRISMATIC GLASS JAR LENS DIE CAST GUARDONE 32 WATT CPFL LAMP. LUMEN RATING = 2400 LMS.SIMULATED REPORT FROM TEST WITH 42 WATT LAMPTotal Luminaire Efficiency = 67.6%
Test Report 20865A
387 SERIES MODEL #: 387-CFL26-C
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .73 .73 .73 .73 .68 .68 .68 .68 .59 .59 .59 .50 .50 .50 .42 .42 .42 .38 1 .63 .58 .54 .50 .58 .54 .50 .46 .45 .42 .40 .37 .35 .33 .30 .28 .27 .23 2 .56 .48 .43 .38 .51 .45 .39 .35 .37 .33 .29 .30 .27 .24 .24 .22 .19 .16 3 .50 .41 .35 .29 .45 .38 .32 .27 .31 .27 .23 .26 .22 .19 .20 .17 .15 .12 4 .45 .36 .29 .24 .41 .33 .27 .22 .27 .22 .18 .22 .18 .15 .17 .14 .12 .09 5 .41 .31 .25 .20 .37 .29 .23 .18 .24 .19 .15 .19 .15 .12 .15 .12 .09 .07 6 .37 .28 .21 .16 .34 .25 .19 .15 .21 .16 .13 .17 .13 .10 .13 .10 .08 .06 7 .34 .25 .18 .14 .31 .23 .17 .13 .19 .14 .11 .15 .12 .09 .12 .09 .07 .05 8 .32 .22 .16 .12 .29 .20 .15 .11 .17 .13 .09 .14 .10 .07 .11 .08 .06 .04 9 .29 .20 .14 .10 .27 .19 .13 .10 .15 .11 .08 .13 .09 .06 .10 .07 .05 .03 10 .27 .18 .13 .09 .25 .17 .12 .08 .14 .10 .07 .12 .08 .06 .09 .06 .04 .03
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 42.35 2.4 3.5 0-40 92.94 5.2 7.6 0-60 270.03 15 22.2 0-90 678.37 37.7 55.7 90-120 379.44 21.1 31.2 90-130 460.31 25.6 37.8 90-150 533.45 29.6 43.8 90-180 539.1 29.9 44.3 0-180 1217.47 67.6 100
VAPOR PROOF - CFL CEILINGCLEAR LINEAR PRISMATIC GLASS JAR LENS DIE CAST GUARDONE 26 WATT CPFL LAMP. LUMEN RATING = 1800 LMS.SIMULATED REPORT FROM TEST WITH 42 WATT LAMPTotal Luminaire Efficiency = 67.6%
Test Report 20865B
387 SERIES MODEL #: 387-CFL32-BB
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .72 .72 .72 .72 .67 .67 .67 .67 .58 .58 .58 .50 .50 .50 .42 .42 .42 .39 1 .62 .57 .53 .49 .57 .53 .49 .45 .45 .42 .39 .37 .35 .33 .31 .29 .27 .24 2 .54 .47 .41 .36 .50 .44 .38 .34 .37 .33 .29 .30 .27 .24 .25 .22 .20 .17 3 .49 .40 .34 .28 .45 .37 .31 .26 .31 .26 .22 .26 .22 .19 .20 .17 .15 .12 4 .44 .35 .28 .23 .40 .32 .26 .21 .27 .22 .18 .22 .18 .15 .17 .14 .12 .09 5 .40 .30 .24 .19 .36 .28 .22 .17 .23 .18 .15 .19 .15 .12 .15 .12 .09 .07 6 .36 .27 .20 .16 .33 .25 .19 .15 .21 .16 .12 .17 .13 .10 .14 .10 .08 .06 7 .34 .24 .18 .13 .31 .22 .16 .12 .19 .14 .10 .15 .11 .08 .12 .09 .07 .05 8 .31 .22 .16 .11 .28 .20 .14 .11 .17 .12 .09 .14 .10 .07 .11 .08 .06 .04 9 .29 .19 .14 .10 .26 .18 .13 .09 .15 .11 .08 .13 .09 .06 .10 .07 .05 .03 10 .27 .18 .12 .09 .25 .16 .11 .08 .14 .10 .07 .12 .08 .06 .09 .06 .04 .03
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 55.45 2.3 3.5 0-40 123.33 5.1 7.8 0-60 366.94 15.3 23.1 0-90 934.06 38.9 58.8 90-120 485.39 20.2 30.6 90-130 576.93 24 36.3 90-150 651.31 27.1 41 90-180 653.68 27.2 41.2 0-180 1587.74 66.2 100
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
VAPOR PROOF - CFL BRACKET/BOXCLEAR LINEAR PRISMATIC GLASS JAR LENS DIE CAST GUARDONE 32 WATT CPFL LAMP. LUMEN RATING = 2400 LMS.SIMULATED REPORT FROM TEST WITH 42 WATT LAMPTotal Luminaire Efficiency = 66.2%
Test Report 20864A
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 117
www.ldpi-inc.com
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .73 .73 .73 .73 .68 .68 .68 .68 .59 .59 .59 .50 .50 .50 .42 .42 .42 .38 1 .63 .58 .54 .50 .58 .54 .50 .46 .45 .42 .40 .37 .35 .33 .30 .28 .27 .23 2 .56 .48 .43 .38 .51 .45 .39 .35 .37 .33 .29 .30 .27 .24 .24 .22 .19 .163 .50 .41 .35 .29 .45 .38 .32 .27 .31 .27 .23 .26 .22 .19 .20 .17 .15 .12 4 .45 .36 .29 .24 .41 .33 .27 .22 .27 .22 .18 .22 .18 .15 .17 .14 .12 .09 5 .41 .31 .25 .20 .37 .29 .23 .18 .24 .19 .15 .19 .15 .12 .15 .12 .09 .07 6 .37 .28 .21 .16 .34 .25 .19 .15 .21 .16 .13 .17 .13 .10 .13 .10 .08 .06 7 .34 .25 .18 .14 .31 .23 .17 .13 .19 .14 .11 .15 .12 .09 .12 .09 .07 .05 8 .32 .22 .16 .12 .29 .20 .15 .11 .17 .13 .09 .14 .10 .07 .11 .08 .06 .04 9 .29 .20 .14 .10 .27 .19 .13 .10 .15 .11 .08 .13 .09 .06 .10 .07 .05 .03 10 .27 .18 .13 .09 .25 .17 .12 .08 .14 .10 .07 .12 .08 .06 .09 .06 .04 .03
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 75.29 2.4 3.5 0-40 165.23 5.2 7.6 0-60 480.06 15 22.2 0-90 1206.02 37.7 55.7 90-120 674.53 21.1 31.2 90-130 818.29 25.6 37.8 90-150 948.35 29.6 43.8 90-180 958.43 30 44.3 0-180 2164.45 67.6 100
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
VAPOR PROOF - CFL CEILINGCLEAR LINEAR PRISMATIC GLASS JAR LENS DIE CAST GUARDONE PHILIPS 42 WATT CPFL LAMPPL-T 42W/41/4P. LUMEN RATING = 3200 LMS.ONE ROBERTSON RSM226CQMVDW BALLAST OPERATING AT 120 VAC AND 42 WATTSTotal Luminaire Efficiency = 67.6%
387 SERIES MODEL #: 387-CFL42-C Test Report 20865
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .72 .72 .72 .72 .67 .67 .67 .67 .58 .58 .58 .50 .50 .50 .42 .42 .42 .39 1 .62 .57 .53 .49 .57 .53 .49 .45 .45 .42 .39 .37 .35 .33 .31 .29 .27 .24 2 .54 .47 .41 .36 .50 .44 .38 .34 .37 .33 .29 .30 .27 .24 .25 .22 .20 .17 3 .49 .40 .34 .28 .45 .37 .31 .26 .31 .26 .22 .26 .22 .19 .20 .17 .15 .12 4 .44 .35 .28 .23 .40 .32 .26 .21 .27 .22 .18 .22 .18 .15 .17 .14 .12 .09 5 .40 .30 .24 .19 .36 .28 .22 .17 .23 .18 .15 .19 .15 .12 .15 .12 .09 .07 6 .36 .27 .20 .16 .33 .25 .19 .15 .21 .16 .12 .17 .13 .10 .14 .10 .08 .06 7 .34 .24 .18 .13 .31 .22 .16 .12 .19 .14 .10 .15 .11 .08 .12 .09 .07 .05 8 .31 .22 .16 .11 .28 .20 .14 .11 .17 .12 .09 .14 .10 .07 .11 .08 .06 .04 9 .29 .19 .14 .10 .26 .18 .13 .09 .15 .11 .08 .13 .09 .06 .10 .07 .05 .03 10 .27 .18 .12 .09 .25 .16 .11 .08 .14 .10 .07 .12 .08 .06 .09 .06 .04 .03
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 73.94 2.3 3.5 0-40 164.43 5.1 7.8 0-60 489.25 15.3 23.1 0-90 1245.43 38.9 58.8 90-120 647.2 20.2 30.6 90-130 769.25 24 36.3 90-150 868.45 27.1 41 90-180 871.6 27.2 41.2 0-180 2117.03 66.2 100
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
VAPOR PROOF - CFL BRACKET/BOXCLEAR LINEAR PRISMATIC GLASS JAR LENS DIE CAST GUARDONE PHILIPS 42 WATT CPFL LAMPLUMEN RATING = 3200 LMS.ONE ROBERTSON RSM226CQMVDW OPERATING AT 120 VAC AND 42 WATTSTotal Luminaire Efficiency = 66.2%
387 SERIES MODEL #: 387-CFL42-BB Test Report 20864
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .71 .71 .71 .71 .66 .66 .66 .66 .57 .57 .57 .48 .48 .48 .40 .40 .40 .37 1 .62 .57 .53 .50 .57 .53 .49 .46 .45 .42 .39 .37 .35 .33 .30 .28 .27 .23 2 .55 .48 .42 .38 .50 .44 .39 .35 .37 .33 .30 .30 .27 .25 .24 .22 .20 .17 3 .49 .41 .34 .29 .45 .37 .32 .27 .31 .27 .23 .25 .22 .19 .20 .17 .15 .12 4 .44 .35 .29 .24 .40 .32 .26 .22 .27 .22 .18 .22 .18 .15 .17 .14 .12 .09 5 .40 .31 .24 .20 .36 .28 .22 .18 .24 .19 .15 .19 .15 .12 .15 .12 .10 .07 6 .37 .27 .21 .16 .33 .25 .19 .15 .21 .16 .13 .17 .13 .10 .13 .10 .08 .06 7 .34 .24 .18 .14 .31 .22 .17 .13 .19 .14 .11 .15 .11 .09 .12 .09 .07 .05 8 .31 .22 .16 .12 .28 .20 .15 .11 .17 .12 .09 .14 .10 .07 .11 .08 .06 .04 9 .29 .20 .14 .10 .26 .18 .13 .10 .15 .11 .08 .12 .09 .07 .10 .07 .05 .03 10 .27 .18 .13 .09 .25 .17 .12 .08 .14 .10 .07 .11 .08 .06 .09 .06 .04 .03
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 85.97 2.3 3.5 0-40 222.74 5.9 9 0-60 580.77 15.5 23.5 0-90 1370.85 36.6 55.5 90-120 841.3 22.4 34 90-130 941.51 25.1 38.1 90-150 1100.21 29.3 44.5 90-180 1101.03 29.4 44.5 0-180 2471.88 65.9 100
VAPOR PROOF - HID BRACKET/BOXCLEAR LINEAR PRISMATIC GLASS JAR LENSDIE CAST GUARDONE 50 WATT MH LAMP. LUMEN RATING = 3750 LMS.SIMULATED REPORT FROM TEST WITH 100 WATT LAMPTotal Luminaire Efficiency = 65.9%
387 SERIES MODEL #: 387-MH50-BB Test Report 20862B
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012118
www.ldpi-inc.com
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
387 SERIES MODEL #: 387-MH70-C
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .86 .86 .86 .86 .80 .80 .80 .80 .68 .68 .68 .57 .57 .57 .47 .47 .47 .42 1 .75 .70 .65 .61 .69 .64 .60 .56 .53 .50 .47 .44 .41 .39 .35 .33 .31 .27 2 .66 .58 .52 .46 .60 .53 .47 .42 .44 .40 .36 .36 .32 .29 .28 .25 .23 .19 3 .59 .50 .42 .36 .54 .45 .39 .33 .37 .32 .28 .30 .26 .23 .23 .20 .18 .14 4 .54 .43 .35 .29 .49 .39 .32 .27 .32 .27 .22 .26 .22 .18 .20 .17 .14 .11 5 .49 .38 .30 .24 .44 .34 .27 .22 .28 .23 .18 .23 .18 .15 .17 .14 .11 .08 6 .45 .33 .26 .20 .40 .30 .24 .19 .25 .20 .15 .20 .16 .12 .15 .12 .09 .07 7 .41 .30 .22 .17 .37 .27 .21 .16 .22 .17 .13 .18 .14 .10 .14 .10 .08 .06 8 .38 .27 .20 .15 .34 .24 .18 .14 .20 .15 .11 .16 .12 .09 .13 .09 .07 .05 9 .35 .24 .17 .13 .32 .22 .16 .12 .18 .13 .10 .15 .11 .08 .12 .08 .06 .04 10 .33 .22 .16 .11 .30 .20 .14 .10 .17 .12 .09 .14 .10 .07 .11 .07 .05 .03
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 160.33 2.7 3.3 0-40 420.13 7 8.7 0-60 1061.59 17.7 22 0-90 2523.57 42.1 52.4 90-120 1684.09 28.1 35 90-130 1919.7 32 39.9 90-150 2285.57 38.1 47.5 90-180 2291.29 38.2 47.6 0-180 4814.86 80.2 100
VAPOR PROOF - HID CEILINGCLEAR LINEAR PRISMATIC GLASS JAR LENSDIE CAST GUARDONE 70 WATT MH LAMP MH100W/U/PS. LUMEN RATING = 6000 LMS.SIMULATED REPORT FROM TEST WITH 100 WATT LAMPTotal Luminaire Efficiency = 80.2%
Test Report 20861A
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .86 .86 .86 .86 .80 .80 .80 .80 .68 .68 .68 .57 .57 .57 .47 .47 .47 .42 1 .75 .70 .65 .61 .69 .64 .60 .56 .53 .50 .47 .44 .41 .39 .35 .33 .31 .27 2 .66 .58 .52 .46 .60 .53 .47 .42 .44 .40 .36 .36 .32 .29 .28 .25 .23 .19 3 .59 .50 .42 .36 .54 .45 .39 .33 .37 .32 .28 .30 .26 .23 .23 .20 .18 .14 4 .54 .43 .35 .29 .49 .39 .32 .27 .32 .27 .22 .26 .22 .18 .20 .17 .14 .11 5 .49 .38 .30 .24 .44 .34 .27 .22 .28 .23 .18 .23 .18 .15 .17 .14 .11 .08 6 .45 .33 .26 .20 .40 .30 .24 .19 .25 .20 .15 .20 .16 .12 .15 .12 .09 .07 7 .41 .30 .22 .17 .37 .27 .21 .16 .22 .17 .13 .18 .14 .10 .14 .10 .08 .06 8 .38 .27 .20 .15 .34 .24 .18 .14 .20 .15 .11 .16 .12 .09 .13 .09 .07 .05 9 .35 .24 .17 .13 .32 .22 .16 .12 .18 .13 .10 .15 .11 .08 .12 .08 .06 .04 10 .33 .22 .16 .11 .30 .20 .14 .10 .17 .12 .09 .14 .10 .07 .11 .07 .05 .03
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 100.19 2.7 3.3 0-40 262.55 7 8.7 0-60 663.48 17.7 22 0-90 1577.23 42.1 52.4 90-120 1052.56 28.1 35 90-130 1199.85 32 39.9 90-150 1428.53 38.1 47.5 90-180 1432.11 38.2 47.6 0-180 3009.33 80.2 100
VAPOR PROOF - HID CEILINGCLEAR LINEAR PRISMATIC GLASS JAR LENSDIE CAST GUARDONE 50 WATT MH LAMP MH100W/U/PS. LUMEN RATING = 3750 LMS.SIMULATED REPORT FROM TEST WITH 100 WATT LAMPTotal Luminaire Efficiency = 80.2%
387 SERIES MODEL #: 387-MH50-C Test Report 20861B
387 SERIES MODEL #: 387-MH70-BB
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .71 .71 .71 .71 .66 .66 .66 .66 .57 .57 .57 .48 .48 .48 .40 .40 .40 .37 1 .62 .57 .53 .50 .57 .53 .49 .46 .45 .42 .39 .37 .35 .33 .30 .28 .27 .23 2 .55 .48 .42 .38 .50 .44 .39 .35 .37 .33 .30 .30 .27 .25 .24 .22 .20 .17 3 .49 .41 .34 .29 .45 .37 .32 .27 .31 .27 .23 .25 .22 .19 .20 .17 .15 .12 4 .44 .35 .29 .24 .40 .32 .26 .22 .27 .22 .18 .22 .18 .15 .17 .14 .12 .09 5 .40 .31 .24 .20 .36 .28 .22 .18 .24 .19 .15 .19 .15 .12 .15 .12 .10 .07 6 .37 .27 .21 .16 .33 .25 .19 .15 .21 .16 .13 .17 .13 .10 .13 .10 .08 .06 7 .34 .24 .18 .14 .31 .22 .17 .13 .19 .14 .11 .15 .11 .09 .12 .09 .07 .05 8 .31 .22 .16 .12 .28 .20 .15 .11 .17 .12 .09 .14 .10 .07 .11 .08 .06 .04 9 .29 .20 .14 .10 .26 .18 .13 .10 .15 .11 .08 .12 .09 .07 .10 .07 .05 .03 10 .27 .18 .13 .09 .25 .17 .12 .08 .14 .10 .07 .11 .08 .06 .09 .06 .04 .03
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 137.56 2.3 3.5 0-40 356.39 5.9 9 0-60 929.24 15.5 23.5 0-90 2193.39 36.6 55.590-120 1346.08 22.4 34 90-130 1506.39 25.1 38.1 90-150 1760.32 29.3 44.5 90-180 1761.64 29.4 44.5 0-180 3955.03 65.9 100
VAPOR PROOF - HID BRACKETCLEAR LINEAR PRISMATIC GLASS JAR LENS DIE CAST GUARDONE 70 WATT MH LAMP. LUMEN RATING = 6000 LMS.SIMULATED REPORT FROM TEST WITH 100 WATT LAMPTotal Luminaire Efficiency = 65.9%
Test Report 20862A
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 119
www.ldpi-inc.com
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .71 .71 .71 .71 .66 .66 .66 .66 .57 .57 .57 .48 .48 .48 .40 .40 .40 .37 1 .62 .57 .53 .50 .57 .53 .49 .46 .45 .42 .39 .37 .35 .33 .30 .28 .27 .23 2 .55 .48 .42 .38 .50 .44 .39 .35 .37 .33 .30 .30 .27 .25 .24 .22 .20 .17 3 .49 .41 .34 .29 .45 .37 .32 .27 .31 .27 .23 .25 .22 .19 .20 .17 .15 .12 4 .44 .35 .29 .24 .40 .32 .26 .22 .27 .22 .18 .22 .18 .15 .17 .14 .12 .09 5 .40 .31 .24 .20 .36 .28 .22 .18 .24 .19 .15 .19 .15 .12 .15 .12 .10 .07 6 .37 .27 .21 .16 .33 .25 .19 .15 .21 .16 .13 .17 .13 .10 .13 .10 .08 .06 7 .34 .24 .18 .14 .31 .22 .17 .13 .19 .14 .11 .15 .11 .09 .12 .09 .07 .05 8 .31 .22 .16 .12 .28 .20 .15 .11 .17 .12 .09 .14 .10 .07 .11 .08 .06 .04 9 .29 .20 .14 .10 .26 .18 .13 .10 .15 .11 .08 .12 .09 .07 .10 .07 .05 .03 10 .27 .18 .13 .09 .25 .17 .12 .08 .14 .10 .07 .11 .08 .06 .09 .06 .04 .03
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 206.34 2.3 3.5 0-40 534.58 5.9 9 0-60 1393.86 15.5 23.5 0-90 3290.09 36.6 55.5 90-120 2019.11 22.4 34 90-130 2259.6 25.1 38.1 90-150 2640.5 29.3 44.5 90-180 2642.47 29.4 44.5 0-180 5932.56 65.9 100
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
VAPOR PROOF - HID BRACKETCLEAR LINEAR PRISMATIC GLASS JAR LENSDIE CAST GUARDONE VENTURE 100 WATT MH LAMP MH100W/U/PS. LUMEN RATING = 9000 LMS.LAMP OPERATING AT 100 WATTSTotal Luminaire Efficiency = 66.2%
387 SERIES MODEL #: 387-MH100-BB Test Report 20862
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .86 .86 .86 .86 .80 .80 .80 .80 .68 .68 .68 .57 .57 .57 .47 .47 .47 .42 1 .75 .70 .65 .61 .69 .64 .60 .56 .53 .50 .47 .44 .41 .39 .35 .33 .31 .27 2 .66 .58 .52 .46 .60 .53 .47 .42 .44 .40 .36 .36 .32 .29 .28 .25 .23 .19 3 .59 .50 .42 .36 .54 .45 .39 .33 .37 .32 .28 .30 .26 .23 .23 .20 .18 .14 4 .54 .43 .35 .29 .49 .39 .32 .27 .32 .27 .22 .26 .22 .18 .20 .17 .14 .11 5 .49 .38 .30 .24 .44 .34 .27 .22 .28 .23 .18 .23 .18 .15 .17 .14 .11 .08 6 .45 .33 .26 .20 .40 .30 .24 .19 .25 .20 .15 .20 .16 .12 .15 .12 .09 .07 7 .41 .30 .22 .17 .37 .27 .21 .16 .22 .17 .13 .18 .14 .10 .14 .10 .08 .06 8 .38 .27 .20 .15 .34 .24 .18 .14 .20 .15 .11 .16 .12 .09 .13 .09 .07 .05 9 .35 .24 .17 .13 .32 .22 .16 .12 .18 .13 .10 .15 .11 .08 .12 .08 .06 .04 10 .33 .22 .16 .11 .30 .20 .14 .10 .17 .12 .09 .14 .10 .07 .11 .07 .05 .03
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 240.47 2.7 3.3 0-40 630.14 7 8.7 0-60 1592.35 17.7 22 0-90 3785.33 42.1 52.4 90-120 2526.13 28.1 35 90-130 2879.54 32 39.9 90-150 3428.35 38.1 47.5 90-180 3436.94 38.2 47.6 0-180 7222.27 80.2 100
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
VAPOR PROOF - HID CEILINGCLEAR LINEAR PRISMATIC GLASS JAR LENS DIE CAST GUARDONE VENTURE 100 WATT MH LAMPMH100W/U/PS. LUMEN RATING = 9000 LMS.LAMP OPERATING AT 100 WATTSTotal Luminaire Efficiency = 80.2%
387 SERIES MODEL #: 387-MH100-C Test Report 20861
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .70 .70 .70 .70 .65 .65 .65 .65 .56 .56 .56 .47 .47 .47 .39 .39 .39 .361 .60 .55 .51 .47 .55 .51 .47 .44 .43 .40 .37 .35 .33 .31 .28 .27 .25 .222 .52 .46 .40 .35 .48 .42 .37 .32 .35 .31 .27 .28 .25 .22 .22 .20 .18 .153 .47 .39 .32 .27 .43 .35 .30 .25 .29 .25 .21 .24 .20 .17 .18 .16 .13 .114 .42 .33 .27 .22 .38 .30 .25 .20 .25 .20 .17 .20 .16 .13 .16 .13 .10 .085 .38 .29 .23 .18 .35 .27 .21 .16 .22 .17 .14 .18 .14 .11 .14 .11 .08 .066 .35 .26 .19 .15 .32 .23 .18 .14 .19 .15 .11 .16 .12 .09 .12 .09 .07 .057 .32 .23 .17 .13 .29 .21 .15 .12 .17 .13 .10 .14 .10 .08 .11 .08 .06 .048 .30 .20 .15 .11 .27 .19 .14 .10 .16 .11 .08 .13 .09 .06 .10 .07 .05 .039 .28 .19 .13 .09 .25 .17 .12 .09 .14 .10 .07 .11 .08 .06 .09 .06 .04 .0310 .26 .17 .12 .08 .23 .16 .11 .07 .13 .09 .06 .11 .07 .05 .08 .05 .04 .02
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 57.92 1.4 2.3 0-40 162.22 4.1 6.3 0-60 516.72 12.9 20.1 0-90 1433.24 35.8 55.7 90-120 875.31 21.9 34 90-130 1002.27 25.1 39 90-150 1137.35 28.4 44.2 90-180 1138.08 28.5 44.3 0-180 2571.31 64.3 100
VAPOR PROOF - HID BRACKETCLEAR LINEAR PRISMATIC GLASS JAR LENS DIE CAST GUARDONE 50 WATT HPS LAMP. LUMEN RATING = 4000 LMS.SIMULATED REPORT FROM TEST WITH 100 WATT LAMPTotal Luminaire Efficiency = 64.3%
387 SERIES MODEL #: 387-S50-BB Test Report 20863B
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012120
www.ldpi-inc.com
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
387 SERIES MODEL #: 387-S70-C
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .83 .83 .83 .83 .77 .77 .77 .77 .66 .66 .66 .55 .55 .55 .45 .45 .45 .41 1 .71 .66 .61 .57 .65 .61 .56 .53 .50 .47 .44 .41 .39 .36 .33 .31 .29 .25 2 .63 .55 .48 .43 .57 .50 .44 .39 .41 .37 .33 .33 .30 .27 .26 .23 .21 .17 3 .56 .47 .39 .33 .51 .43 .36 .31 .35 .30 .25 .28 .24 .20 .21 .18 .15 .12 4 .51 .40 .33 .27 .46 .37 .30 .25 .30 .25 .20 .24 .20 .16 .18 .15 .12 .09 5 .46 .35 .28 .22 .42 .32 .25 .20 .26 .21 .17 .21 .16 .13 .16 .12 .10 .07 6 .42 .31 .24 .18 .38 .28 .22 .17 .23 .18 .14 .18 .14 .11 .14 .11 .08 .05 7 .39 .28 .21 .16 .35 .25 .19 .14 .21 .16 .12 .17 .12 .09 .13 .09 .07 .04 8 .36 .25 .18 .13 .33 .23 .17 .12 .19 .14 .10 .15 .11 .08 .11 .08 .06 .04 9 .33 .23 .16 .12 .30 .21 .15 .11 .17 .12 .09 .14 .10 .07 .10 .07 .05 .03 10 .31 .21 .14 .10 .28 .19 .13 .09 .16 .11 .08 .12 .09 .06 .10 .06 .04 .03
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 108.12 1.7 2.2 0-40 307.46 4.9 6.3 0-60 923.83 14.7 18.9 0-90 2557.02 40.6 52.4 90-120 1727.83 27.4 35.4 90-130 2013.6 32 41.3 90-150 2317.04 36.8 47.5 90-180 2322.64 36.9 47.6 0-180 4879.66 77.5 100
VAPOR PROOF - HID CEILINGCLEAR LINEAR PRISMATIC GLASS JAR LENSDIE CAST GUARDONE 70 WATT HPS LAMP. LUMEN RATING = 6300 LMS.SIMULATED REPORT FROM TEST WITH 100 WATT LAMPTotal Luminaire Efficiency = 77.5%
Test Report 20860A
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .83 .83 .83 .83 .77 .77 .77 .77 .66 .66 .66 .55 .55 .55 .45 .45 .45 .411 .71 .66 .61 .57 .65 .61 .56 .53 .50 .47 .44 .41 .39 .36 .33 .31 .29 .252 .63 .55 .48 .43 .57 .50 .44 .39 .41 .37 .33 .33 .30 .27 .26 .23 .21 .173 .56 .47 .39 .33 .51 .43 .36 .31 .35 .30 .25 .28 .24 .20 .21 .18 .15 .124 .51 .40 .33 .27 .46 .37 .30 .25 .30 .25 .20 .24 .20 .16 .18 .15 .12 .095 .46 .35 .28 .22 .42 .32 .25 .20 .26 .21 .17 .21 .16 .13 .16 .12 .10 .076 .42 .31 .24 .18 .38 .28 .22 .17 .23 .18 .14 .18 .14 .11 .14 .11 .08 .057 .39 .28 .21 .16 .35 .25 .19 .14 .21 .16 .12 .17 .12 .09 .13 .09 .07 .048 .36 .25 .18 .13 .33 .23 .17 .12 .19 .14 .10 .15 .11 .08 .11 .08 .06 .049 .33 .23 .16 .12 .30 .21 .15 .11 .17 .12 .09 .14 .10 .07 .10 .07 .05 .0310 .31 .21 .14 .10 .28 .19 .13 .09 .16 .11 .08 .12 .09 .06 .10 .06 .04 .03
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 68.64 1.7 2.2 0-40 195.21 4.9 6.3 0-60 586.51 14.7 18.9 0-90 1623.47 40.6 52.4 90-120 1097.05 27.4 35.4 90-130 1278.5 32 41.3 90-150 1471.14 36.8 47.5 90-180 1474.69 36.9 47.6 0-180 3098.16 77.5 100
VAPOR PROOF - HID CEILINGCLEAR LINEAR PRISMATIC GLASS JAR LENSDIE CAST GUARDONE 50 WATT HPS LAMP. LUMEN RATING = 4000 LMS.SIMULATED REPORT FROM TEST WITH 100 WATT LAMPTotal Luminaire Efficiency = 77.5%
387 SERIES MODEL #: 387-S50-C Test Report 20860B
387 SERIES MODEL #: 387-S70-BB
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .70 .70 .70 .70 .65 .65 .65 .65 .56 .56 .56 .47 .47 .47 .39 .39 .39 .36 1 .60 .55 .51 .47 .55 .51 .47 .44 .43 .40 .37 .35 .33 .31 .28 .27 .25 .22 2 .52 .46 .40 .35 .48 .42 .37 .32 .35 .31 .27 .28 .25 .22 .22 .20 .18 .15 3 .47 .39 .32 .27 .43 .35 .30 .25 .29 .25 .21 .24 .20 .17 .18 .16 .13 .11 4 .42 .33 .27 .22 .38 .30 .25 .20 .25 .20 .17 .20 .16 .13 .16 .13 .10 .08 5 .38 .29 .23 .18 .35 .27 .21 .16 .22 .17 .14 .18 .14 .11 .14 .11 .08 .06 6 .35 .26 .19 .15 .32 .23 .18 .14 .19 .15 .11 .16 .12 .09 .12 .09 .07 .05 7 .32 .23 .17 .13 .29 .21 .15 .12 .17 .13 .10 .14 .10 .08 .11 .08 .06 .04 8 .30 .20 .15 .11 .27 .19 .14 .10 .16 .11 .08 .13 .09 .06 .10 .07 .05 .03 9 .28 .19 .13 .09 .25 .17 .12 .09 .14 .10 .07 .11 .08 .06 .09 .06 .04 .03 10 .26 .17 .12 .08 .23 .16 .11 .07 .13 .09 .06 .11 .07 .05 .08 .05 .04 .02
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 91.22 1.4 2.3 0-40 255.5 4.1 6.3 0-60 813.84 12.9 20.1 0-90 2257.34 35.8 55.7 90-120 1378.62 21.9 34 90-130 1578.59 25.1 39 90-150 1791.37 28.4 44.2 90-180 1792.53 28.5 44.3 0-180 4049.86 64.3 100
VAPOR PROOF - HID BRACKETCLEAR LINEAR PRISMATIC GLASS JAR LENSDIE CAST GUARDONE 70 WATT HPS LAMP. LUMEN RATING = 6300 LMS.SIMULATED REPORT FROM TEST WITH 100 WATT LAMPTotal Luminaire Efficiency = 64.3%
Test Report 20863A
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 121
www.ldpi-inc.com
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .70 .70 .70 .70 .65 .65 .65 .65 .56 .56 .56 .47 .47 .47 .39 .39 .39 .36 1 .60 .55 .51 .47 .55 .51 .47 .44 .43 .40 .37 .35 .33 .31 .28 .27 .25 .22 2 .52 .46 .40 .35 .48 .42 .37 .32 .35 .31 .27 .28 .25 .22 .22 .20 .18 .15 3 .47 .39 .32 .27 .43 .35 .30 .25 .29 .25 .21 .24 .20 .17 .18 .16 .13 .11 4 .42 .33 .27 .22 .38 .30 .25 .20 .25 .20 .17 .20 .16 .13 .16 .13 .10 .08 5 .38 .29 .23 .18 .35 .27 .21 .16 .22 .17 .14 .18 .14 .11 .14 .11 .08 .06 6 .35 .26 .19 .15 .32 .23 .18 .14 .19 .15 .11 .16 .12 .09 .12 .09 .07 .05 7 .32 .23 .17 .13 .29 .21 .15 .12 .17 .13 .10 .14 .10 .08 .11 .08 .06 .04 8 .30 .20 .15 .11 .27 .19 .14 .10 .16 .11 .08 .13 .09 .06 .10 .07 .05 .03 9 .28 .19 .13 .09 .25 .17 .12 .09 .14 .10 .07 .11 .08 .06 .09 .06 .04 .03 10 .26 .17 .12 .08 .23 .16 .11 .07 .13 .09 .06 .11 .07 .05 .08 .05 .04 .02
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 137.55 1.4 2.3 0-40 385.27 4.1 6.3 0-60 1227.2 12.9 20.1 0-90 3403.89 35.8 55.7 90-120 2078.87 21.9 34 90-130 2380.42 25.1 39 90-150 2701.26 28.4 44.2 90-180 2703 28.5 44.3 0-180 6106.89 64.3 100
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
VAPOR PROOF - HID BRACKETCLEAR LINEAR PRISMATIC GLASS JAR LENS DIE CAST GUARDONE PHILIPS 100 WATT HPS LAMPC100S54/M. LUMEN RATING = 9500 LMS.LAMP OPERATING AT 100 WATTSTotal Luminaire Efficiency = 64.3%
387 SERIES MODEL #: 387-S100-BB Test Report 20863
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .83 .83 .83 .83 .77 .77 .77 .77 .66 .66 .66 .55 .55 .55 .45 .45 .45 .41 1 .71 .66 .61 .57 .65 .61 .56 .53 .50 .47 .44 .41 .39 .36 .33 .31 .29 .25 2 .63 .55 .48 .43 .57 .50 .44 .39 .41 .37 .33 .33 .30 .27 .26 .23 .21 .17 3 .56 .47 .39 .33 .51 .43 .36 .31 .35 .30 .25 .28 .24 .20 .21 .18 .15 .12 4 .51 .40 .33 .27 .46 .37 .30 .25 .30 .25 .20 .24 .20 .16 .18 .15 .12 .09 5 .46 .35 .28 .22 .42 .32 .25 .20 .26 .21 .17 .21 .16 .13 .16 .12 .10 .07 6 .42 .31 .24 .18 .38 .28 .22 .17 .23 .18 .14 .18 .14 .11 .14 .11 .08 .05 7 .39 .28 .21 .16 .35 .25 .19 .14 .21 .16 .12 .17 .12 .09 .13 .09 .07 .04 8 .36 .25 .18 .13 .33 .23 .17 .12 .19 .14 .10 .15 .11 .08 .11 .08 .06 .04 9 .33 .23 .16 .12 .30 .21 .15 .11 .17 .12 .09 .14 .10 .07 .10 .07 .05 .03 10 .31 .21 .14 .10 .28 .19 .13 .09 .16 .11 .08 .12 .09 .06 .10 .06 .04 .03
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 163.01 1.7 2.2 0-40 463.61 4.9 6.3 0-60 1393.04 14.7 18.9 0-90 3855.8 40.6 52.4 90-120 2605.49 27.4 35.4 90-130 3036.4 32 41.3 90-150 3493.92 36.8 47.5 90-180 3502.33 36.9 47.6 0-180 7358.13 77.5 100
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
VAPOR PROOF - HID CEILINGWITH CLEAR LINEAR PRISMATIC GLASS JAR LENSDIE CAST GUARDONE PHILIPS 100 WATT HPS LAMPC100S54/M. LUMEN RATING = 9500 LMS.LAMP OPERATING AT 100 WATTSTotal Luminaire Efficiency = 77.5%
387 SERIES MODEL #: 387-S100-C Test Report 20860
INSPECTION SERIES MODEL #: 39042LINS-3613 LSI Test Report 23117
Plane1 - (0 - 180)2 - (45 - 225)3 - (90 - 270)
WITH SPECULAR REFLECTORS AND BLACK STRIPPED CLEAR FLAT GLASS LENSTWO PHILIPS 32 WATT T8 LAMPSF32T8/TL850. LUMEN RATING = 2850 LMS.Total Luminaire Efficiency 39.9 %Spacing (0-180) 1.22(90-270) 0.56
ZONAL LUMEN SUMMARy Zone Lumens %Lamp %Fixt0-30 747.22 13.1 32.90-40 1214.82 21.3 53.40-60 1970.31 34.6 86.60-90 2274.39 39.9 10090-120 0 0 090-130 0 0 090-150 0 0 090-180 0 0 00-180 2274.39 39.9 100
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHODEffective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .48 .48 .48 .48 .46 .46 .46 .46 .44 .44 .44 .42 .42 .42 .41 .41 .41 .401 .44 .42 .41 .40 .43 .42 .40 .39 .40 .39 .38 .38 .37 .37 .37 .36 .36 .35 2 .41 .38 .35 .33 .40 .37 .35 .33 .35 .34 .32 .34 .33 .31 .33 .32 .31 .30 3 .37 .33 .31 .28 .36 .33 .30 .28 .32 .29 .27 .31 .29 .27 .30 .28 .27 .26 4 .34 .30 .27 .24 .33 .29 .26 .24 .28 .26 .24 .28 .25 .23 .27 .25 .23 .22 5 .32 .27 .24 .21 .31 .26 .23 .21 .26 .23 .21 .25 .22 .21 .24 .22 .20 .20 6 .29 .24 .21 .19 .29 .24 .21 .19 .23 .21 .18 .23 .20 .18 .22 .20 .18 .17 7 .27 .22 .19 .17 .27 .22 .19 .17 .21 .19 .16 .21 .18 .16 .20 .18 .16 .15 8 .26 .20 .17 .15 .25 .20 .17 .15 .20 .17 .15 .19 .17 .15 .19 .16 .15 .14 9 .24 .19 .16 .14 .23 .19 .16 .14 .18 .15 .13 .18 .15 .13 .17 .15 .13 .13 10 .22 .17 .14 .12 .22 .17 .14 .12 .17 .14 .12 .16 .14 .12 .16 .14 .12 .12
PHOTOMETRICSPHOTOMETRICSF O R L D P I , I N C . F I X T U R E S
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012122
www.ldpi-inc.com
• Convenience in Purchasing
• Case Packs = Cost Efficiency
• Competitively Priced
• Lamps Shipped With Fixture Order In Factory Sealed Cartons
Other lamp types available - consult factory
LAMP SPECIFICATIONS
Part Length Kelvin Initial Design Pk. No. Description (Nominal) Wattage Temp Lumens Lumens CRI Qty.
3241 F28T5/841 46” 28 Watt 4100K/T5 2900 2750 85 40 3242 F54T5/841/HO 46” 54 Watt 4100K/T5 5000 4740 85 40 4438 F24T5/841/HO/ALTO 22” 24 Watt 4000K/T5 2000 1900 85 40 4827 F54T5/850/HO/ALTO 46” 54 Watt 5000K/T5 4800 4625 82 40 2098 F17T8/TL841/ALTO 24” 17 Watt 4100K/T8 1375 1310 85 25 3191 F25T8/TL841 36” 25 Watt 4100K/T8 2225 2050 86 25 3271 F25T8/TL950 36” 25 Watt 5000K/T8 1550 1450 98 25 4149 F25T8/TL865 PLUS 36” 25 Watt 6500K/T8 2150 2040 86 25 3114 F32T8/TL850 Alto 48” 32 Watt 5000K/T8 2850 2710 82 30 3220 F32T8/TL741 Alto 48” 32 Watt 4100K/T8 2850 2710 78 25 3273 F32T8/ADV850 Alto 48” 32 Watt 5000K/T8 3100 3025 82 30 3322 F32T8/TL835/Alto 48” 32 Watt 3500K/T8 2950 2800 86 25 3457 F32T8/TL950 48” 32 Watt 5000K/T8 2000 1860 98 25 3667 F48T8/TL841/HO/Alto 46” 44 Watt 4100K/T8 4000 3600 86 25 4152 F32T8/TL865 PLUS/Alto 48” 32 Watt 6500K/T8 2850 2710 86 25 3158 F40T8/TL841 Alto 60” 40 Watt 4100K/T8 3775 3500 86 25 3274 F96T8/HO/TL841 Plus Alto 96” 86 Watt 4100K/T8 8200 7625 86 25 3275 F96T8/TL841 Plus Alto 96” 59 Watt 4100K/T8 5900 5490 86 24 3552 F96T8/TL850 96” 59 Watt 5000K/T8 5780 5375 86 24
T5
T8
FLUORESCENT LAMPSFLUORESCENT LAMPSF O R L D P I , I N C . F I X T U R E S
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 123
www.ldpi-inc.com
Other lamp types available - consult factory
Part Initial Pk. No. Description Bulb Wattage Base Lumens CRI Qty.
3984 Metal Halide ED-37 400 Watt Mog. 36,000 65 6 3985 Metal Halide ED-28 250 Watt Mog. 20,500 65 12 3986 Metal Halide ED-28 175 Watt Mog. 13,500 65 12 3987 Metal Halide ED-17 175 Watt Med. 13,500 65 12 3988 High Pressure Sodium ED-18 400 Watt Mog. 50,000 21 12 3989 High Pressure Sodium ED-18 250 Watt Mog. 27,000 21 12 3990 High Pressure Sodium ED-23 1/2 150 Watt Mog. 15,800 21 12 3991 High Pressure Sodium ED-23 1/2 100 Watt Mog. 9.400 21 12 3992 High Pressure Sodium ED-23 1/2 70 Watt Mog. 6,500 21 12
ED18Mog
ED23 1/2Mog
ED28Mog
ED37Mog
ED17Med
A23Med
A19Med
PS25Med
LAMP SPECIFICATIONS
LAMP SPECIFICATIONS
Other lamp types available - consult factory
Part Initial Pk. No. Description Bulb Wattage Base Lumens Qty.
3997 Clear A-23 200 Watt Med. 3850 12 3998 Clear A-19 100 Watt Med. 1470 24 3999 Clear A-19 75 Watt Med. 1180 24 4034 Clear PS-25 300 Watt Med. 6280 60 4327 Frosted PS-25 300 Watt Med. 6300 6
H.I.D. LAMPSH.I.D. LAMPSF O R L D P I , I N C . F I X T U R E S
INCANDESCENT LAMPSINCANDESCENT LAMPSF O R L D P I , I N C . F I X T U R E S
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012124
www.ldpi-inc.com
BALLAST SPECIFICATIONS
Starting Rapid,Part Number Input Ballast Temp. Line Current Program or
No. Description of Lamps Length Watts Factor ( F/C) THD Volts (Amps) Instant Start
4425 T5 28 W 2 4 64 1 0/-18 10 120-277 0.55 - 0.23 P4450 T5HO 24 W 2 2 52 1 0/-18 10 120-277 0.44 - 0.19 P3265 T5HO 54 W 2 4 120 1 -20/-29 10 120-277 1.00 - 0.43 P4843 T5HO 54 W 4 4 240 1 -20/-29 10 120-277 2.00 - 0.86 P3613 T8 25 W 2 3 48 .91 0/-18 10 120-277 0.40 - 0.18 I3276 T8 25 W 2 3 48 .98 0/-18 25 347 0.14 I3613 T8 32 W 2 4 59 .88 0/-18 10 120-277 0.49 - 0.22 I3276 T8 32 W 2 4 59 .87 0/-18 20 347 0.17 I4766 T8 32 W 3 4 90 .97 0/-18 20 347 0.26 I3546 T8 25 W 4 3 89 .91 0/-18 10 120-277 0.74 - 0.32 I3125 T8 32 W 4 4 112 .85 0/-18 20 347 0.31 I3546 T8 32 W 4 4 112 .88 0/-18 10 120-277 0.94 - 0.41 I4194 T8 40 W 2 5 77 1.0 0/-18 10 120-277 0.65 - 0.28 I3281 T8 59 W 2 8 110 .85 32/0 20 120-277 0.95 - 0.40 I4854 T8HO 44 W 2 4 98 .95 -20/-29 10 120-277 0.84 - 0.36 P4854 T8HO 86 W 2 8 185 .95 -20/-29 10 120-277 1.57 - 0.68 P3792 T8HO 44 W 4 4 203 1.0 -20/-30 20 277 0.85 I3794 T8HO 44 W 2 4 96 1.0 -20/-30 20 277 0.48 I4156 T8HO 44 W 2 4 96 1.0 -20/-30 20 120 1.15 I4157 T8HO 44 W 4 4 203 1.0 -20/-30 20 120 1.82 I5424 T8 17 & 32 W 2 4 58 0.87 0/-18 <10 120-277 0.48 - 0.12 I5425 T8 17 & 32 W 4 4 112 0.87 0/-18 <10 120-277 0.94 - 0.22 I 5470 T8 17 & 32 W 3 4 86 0.87 0/-18 <10 120-277 0.72 - 0.18 I6975 T8 32 W HLO 2 4 76 1.15 0/-18 20 120-277 0.65 - 0.28 I
Other ballast types available - consult factory
T5
T8
BALLASTSBALLASTSF O R L D P I , I N C . F I X T U R E S
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 125
www.ldpi-inc.com
• 3 Mil plastic with custom acrylic adhesive
• Protects lens coverings from overspray
• Applies easily to clean lens
• Available In 12”, 18” & 25” widths
• 100 Feet per roll
12” Film - Part Number: 3263Single Roll or Case of 4
18” Film - Part Number: 3188Single Roll or Case of 2
25” Film - Part Number: 4348Single Roll
NOTE: Does not fit on 3312 Handle
Dispenser Handle - Part Number: 3312NOTE: For 12” & 18” Film Rolls ONLY
• Helps protect fixture from high pressure blast media• 1/16” clear polycarbonate lens• Lenses are easily interchangeable• Perfect for rear access fixtures• For front access, lens cover needs to be removed for relamping.
2 3/4”
FastenersNot Included
in Kit
BlastBooth Panel 24 3/4”
(4 lamp)30 7/8”(6 lamp)
29”
29”
Booth Interior
LENS PROTECTIONLENS PROTECTIONF O R L D P I , I N C . F I X T U R E S
CLING-ON PLASTIC LENS FILM
BLAST BOOTH LENS COVER
FIXTURE PRESERVATION
For use with the Slim Light and 400 Series
For use with 4 lamp fixtures For use with 6 lamp fixturesLens Kit - P/N 3318 Lens Kit - P/N 7668
Lens Only - P/N 3316 Lens Only - P/N 7682
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012126
www.ldpi-inc.com
In addition to these two government agencies both countries have state, city and county inspectors that may or may not accept the national standards
Hazardous Locations and The National Electrical Code
Hazardous Location Standards are laid out in the following guidelines:
• The NEC (National Electric Code) for the USA
• The CEC (Canadian Electric Code) for CanadaIn both countries these guides are accepted and used by most authorities as the final standard on installation and use of electrical products. These 2 guides with the issuance of the new NEC standard are almost identical.
In the United States of America the government agency responsible is Occupational Safety and Health Administration. OSHA has authorized a group of NRTL (Nationally Recognized Testing Laboratories). At this time the following laboratories are recognized.
• CSA (Canadian Standards Association)• ETL Testing Laboratories Incorporated• Factory Mutual Research Corporation• MET Laboratories• UL (Underwriters Laboratories Inc.)• United States Testing Co. Inc.
In Canada the government agency responsible is the Standards Council of Canada. Standards Council of Canada has authorized a group of testing laboratories to certify equipment. At this time the following laboratories are authorized.• CSA (Canadian Standards Association)• ETL Testing Laboratories Incorporated• UL (Underwriters Laboratories Inc.)• C-UL (Underwriters’ Laboratories of Canada)
ELECTRICAL CODEThe National Electrical Code treats installations in hazardous locations in articles 500 through 516. Hazardous locations are classified by NEC definitions. The following are interpretations of these classifications and applications.
CLASS I LOCATIONSClass I locations are those in which inflammable gases or vapors are or may be present in sufficient quantities to produce explosive or flammable mixtures.
CLASS I, DIVISION 1Class I, Division 1 locations are where hazardous atmosphere may be present during normal operations. It may be present continuously, intermittently, periodically or during normal repair or maintenance operations, or those areas where a breakdown in processing equipment releases hazardous vapors with the simultaneous failure of electrical equipment.
CLASS I, DIVISION 2Class I, Division 2 locations are those in which volatile flammable liquids or gases are handled, processed or used. Normally they will be confined within closed containers or in closed systems from which they can escape only in the case of rupture or deterioration of the containers or systems.
CLASS II LOCATIONSClass II locations are those that are hazardous because of the presence of combustible dust.
CLASS II, DIVISION 1Class II, Division 1 locations include areas where combustible dust may be in suspension in the air under normal conditions in sufficient quantities to produce explosive or ignitable mixtures (Dust may be emitted into the air continuously, intermittently or periodically), or where failure or malfunction of equipment might cause a hazardous location to exist and provide an ignition source with the simultaneous failure of electrical equipment, included also are locations in which combustible dust of an electrically conductive nature may be present.
CLASS II, DIVISION 2Class II, Division 2 locations are those in which combustible dust will not normally be in suspension nor will normal operations put dust in suspension, but where accumulation of dust may interfere with heat dissipation from electrical equipment or where accumulations near electrical equipment may be ignited.
CLASS III LOCATIONSClass III locations are those considered hazardous due to the presence of easily ignitable fibers or flyings, which are in quantities sufficient to produce ignitable mixtures.
CLASS III, DIVISION 1Locations in which easily ignitable fibers or materials producing combustible flyings are handled, manufactured or used.
CLASS III, DIVISION 2Locations where easily ignitable fibers are stored or handled.
This information is provided as a simplified guide only. For actual installation, use the NEC/CEC code book and IEC/CENELEC approvals and wiring codes as final authority on any installation. For paint booth applications consult NFPA Article 33.
HAZARDOUS LOCATIONHAZARDOUS LOCATIONF U N D A M E N TA L S
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 127
www.ldpi-inc.com
CLASS I - FLAMMABLE GASES, VAPORS OR LIQUIDS
Class I, Division 1 and 2 Protection Methods
Area
Div. 1
Div. 2
Protection Methods
• Explosion proof• Intrinsically safe (2 fault);• Purged/pressurized (Type X or Y)
• Nonincendive• Non-sparking device• Purged/pressurized (Type Z)• Hermetically sealed• Any Class I, Div. 1 method
Applicable Certification Standards U.S.
ANSI/UL 1203ANSI/UL 913ANSI/NFPA 496
UL 1604UL 1604ANSI/NFPA 496UL 1604----
Canada
CSA-30CSA-157ANSI/NFPA 496
CSA-213CSA-213ANSI/NFPA 496CSA-213----
Class I, Zone 0, 1 and 2 Protection Methods
Area
ZONE 0
ZONE 1
ZONE 2
Protection Methods
• Intrinsically safe, ‘ia’ (2 fault);• Class I, Div. 1 intrinsically safe(2 fault method)
• Encapsulation, ‘m’• Flameproof ‘d’• Increased safety, ‘e’• Intrinsically safe ’ib’ (1 fault)• Oil immersion ‘o’• Powder filling ‘q’• Purged/pressurized ‘p’• Any Class I, Zone 0 method• Any Class I, Div. 1 method
• Nonincendive ‘nC’• Non-sparking device ‘nA’• Restricted breathing, ‘nR’• Hermetically sealed ‘nC’• Any Class I, Zone 0 or 1 method• Any Class I, Div. 1 or 2 method
Applicable Certification Standards U.S.
UL 2279, Pt. 11ANSI/UL 913
UL 2279, Pt. 18UL 2279, Pt. 1UL 2279, Pt. 7UL 2279, Pt. 11UL 2279UL 2279UL 2279, Pt. 2--------
UL 2279, Pt. 15UL 2279, Pt. 15UL 2279, Pt. 15UL 2279, Pt. 15--------
Canada
CSA-E79-11CSA-157
CSA-E79-18CSA-E79-1CSA-E79-7CSA-E79-11CSA-E79-6CSA-E79-5CSA-E79-2--------
CSA-E79-15CSA-E79-15CSA-E79-15CSA-E79-15--------
IEC
IEC 79-11----
IEC 79-18IEC 79-1IEC 79-7IEC 79-11IEC 79-6IEC 79-5IEC 79-2--------
IEC 79-15IEC 79-15IEC 79-15IEC 79-15--------
EUROPE
EN 50020----
EN 50028EN 50018EN 50019EN 50020EN 50015EN 50017EN 50016--------
prEN 50021prEN 50021prEN 50021prEN 50021--------
Zone 0:Where ignitable concentrations of flammable gases, vapors or liquids can exist all of the time or for long periods of time under normal operating conditions.Zone 1:Where ignitable concentrations of flammable gases, vapors or liquids can exist some of the time under normal operating conditions.Zone 2:Where ignitable concentrations of flammable gases, vapors or liquids can exist some of the time under normal operating conditions.
Division 1:Where ignitable concentrations of flammable gases, vapors or liquids can exist all of the time or some of the time under normal operating conditions.Division 2:Where ignitable concentrations of flammable gases, vapors or liquids are not likely to exist under normal operating conditions.
Class I Area Classifications
Division 1 & 2A (acetylene)B (hydrogen)C (ethylene)D (propane)
Zone 0, 1 & 2IIC (acetylene &
hydrogen)IIB (ethylene)IIA (propane)
Class I Groups
Division 1 & 2T1 (<450ºC)T2 (<300ºC)
T2A, T2B, T2C, T2D(<280ºC, <260ºC, <230ºC, <215ºC)
T3 (<200ºC)T3A, T3B, T3C
(<180ºC, <165ºC, <160ºC)T4 (<135ºC)
T4A (<120ºC)T5 (<100ºC)T6 (<85ºC)
Class I Temperature Codes
Zone 0, 1 & 2T1 (<450ºC)T2 (<300ºC)
T3 (<200ºC)
T4 (<135ºC)
T5 (<100ºC) T6 (<85ºC)
HAZARDOUS LOCATIONHAZARDOUS LOCATIONC L A S S I A R E A C L A S S I F I C AT I O N S
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012128
www.ldpi-inc.com
CLASS II Groups
Division 1 & 2E (metals)
F (coal)G (grain)
Class II, Division 1 and 2 Protection Methods
Area
Div. 1
Div. 2
Protection Methods
• Dust-ignition• Intrinsically safe• Pressurized
• Dust tight• Nonincendive• Non-sparking• Pressurized• Any Class II, Div. 1 method
Applicable Certification Standards U.S.
ANSI/UL 1203ANSI/UL 913ANSI/NFPA 496
UL 1604UL 1604UL 1604ANSI/NFPA 496----
Canada
CSA-25 or CSA-E1241-1-1CSA-157ANSI/NFPA 496
CSA-157 or CSA-E1241-1-1--------ANSI/NFPA 496----
Class II Temperature Codes
Division 1 & 2T1 (<450ºC)T2 (<300ºC)
T2A, T2B, T2C, T2D(<280ºC, <260ºC, <230ºC, <215ºC)
T3 (<200ºC)T3A, T3B, T3C
(<180ºC, <165ºC, <160ºC) T4 (<135ºC)
T4A (<120ºC) T5 (<100ºC) T6 (<85ºC)
Division 1:Where ignitable concentrations of combustible dusts can exist all of the time or some of the time under normal operating conditions.
Class II Area Classifications
Division 2:Where ignitable concentrations of combustible dusts are not likely to exist under normal operating conditions.
Hazardous Location MarkingsClass I, II & III, Division 1 & 2 (U.S. & Canada) - This marking would include: Class(es), Division(s), Gas/Dust Group(s), Temperature CodeExample: Class I, Division 1, Group C & D, T4A
Class I, Zone 0, 1 and 2 (U.S. & Canada) - This marking would include:Method A: For Zone Listings based on UL 2279 or the CSA-E79 Series Class, Zone(s), Ex, Protection Method(s), Gas Group, Temperature Code Example: Class I, Zone 1, Ex de IIB T4 Method B: For Zone Listings based on UL or CSA Division Standards Class, Zone(s), Gas Group, Temperature Code Example: Class I, Zone 1, Group IIB, T4
Note: For Canadian Zone Listings based on the CSA-E79 Series, the “Class” and “Zone” elements of the markings string are optional
Zone 0, 1 and 2 (IEC only) - This marking would include: Ex, Protection Method(s), Gas Group, Temperature Code Example: Ex de IIB T4
Zone 0, 1 and 2 (Europe only) - This marking would include: EEx, Protection Method(s), Gas Group, Temperature Code Example: EEx de IIB T4
CLASS II - COMBUSTIBLE DUSTS
HAZARDOUS LOCATIONHAZARDOUS LOCATIONC L A S S I I A R E A C L A S S I F I C AT I O N S
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 129
www.ldpi-inc.com
CLASS III - IGNITABLE FIBERS AND FLYINGS
CLASS III Groups
Division 1 & 2
NONE
Class III Temperature Codes
Division 1 & 2T1 (<450ºC)T2 (<300ºC)
T2A, T2B, T2C, T2D(<280ºC, <260ºC, <230ºC, <215ºC)
T3 (<200ºC)T3A, T3B, T3C
(<180ºC, <165ºC, <160ºC) T4 (<135ºC)
T4A (<120ºC) T5 (<100ºC) T6 (<85ºC)
Division 1:Where ignitable concentrations of ignitable fibers and flyings can exist all of the time or some of the time under normal operating conditions.
Class III Area Classifications
Division 2:Where ignitable concentrations of ignitable fibers and flyings are not likely to exist under normal operating conditions.
Class III, Division 1 and 2 Protection Methods
Area
Div. 1
Div. 2
Protection Methods
• Dust tight• Intrinsically safe
• Dust tight• Any Class II or III Div. 1 method
Applicable Certification Standards U.S.
ANSI/UL 1604ANSI/UL 913
UL 1604----
Canada
CSA-157CSA-157
CSA-157 ----
Hazardous Location Markings
ANSI/UL 674 Electric Motors and Generators for Use in Division 1 Hazardous (Classified) Locations ANSI/UL 698 Industrial Control Equipment for Use in Hazardous (Classified) Locations ANSI/UL 781 Portable Electric Lighting Units for Use in Hazardous (Classified) Locations ANSI/UL 783 Electric Flashlights and Lanterns for Use in Hazardous (Classified) Locations ANSI/UL 823 Electric Heaters for Use in Hazardous (Classified) Locations ANSI/UL 844 Electric Lighting Fixtures for Use in Hazardous (Classified) Locations ANSI/UL 877 Circuit Breakers and Circuit-Breaker Enclosures for Use in Hazardous (Classified) Locations ANSI/UL 886 Outlet Boxes and Fittings for Use in Hazardous (Classified) Locations ANSI/UL 894 Switches for Use in Hazardous (Classified) LocationsANSI/UL 913 Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II and III, Division 1, Hazardous (Classified) Locations ANSI/UL 1002 Electrically Operated Valves for use in Hazardous (Classified) Locations ANSI/UL 1010 Receptacle-Plug Combinations for Use in Hazardous (Classified) Locations ANSI/UL 1067 Electrically Conductive Equipment and Materials for Use in Flammable Anesthetizing Locations ANSI/UL 1203 Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations ANSI/UL 1207 Sewage Pumps for Use in Hazardous (Classified) Locations UL 1604 Electrical Equipment for Use in Class I and II, Division 2, and Class III Hazardous (Classified) Locations UL 2208 Solvent Distillation Units UL 2225 Metal-Clad Cables and Cable-Sealing Fittings for Use in Hazardous (Classified) Locations UL 2279 Electrical Equipment for use in Class I, Zone 0, 1 and 2 Hazardous (Classified) Locations
HAZARDOUS LOCATIONHAZARDOUS LOCATIONC L A S S I I I A R E A C L A S S I F I C AT I O N S
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012130
www.ldpi-inc.com
IP CODEEnclosure Type DesignationEnclosures serve the dual purpose of protecting personnel from incidental contact with the enclosed electrical equipment and protecting the enclosed equipment against specified environmental conditions. Enclosures are rated for use in specific environmental conditions by international and national standards organizations. The major international rating system uses the IEC Enclosure Classification Designation.
The IECFounded in 1906, the International Electrotechnical Commission (IEC) is the global organization that prepares and publishes international standards for all electrical and related technologies. The membership consists of more than 60 participating countries, including the USA and Canada. Central office of IEC is located in Geneva Switzerland. IEC web site: www.iec.ch
International Standard IEC 60529IEC International Standard 60529 “Degrees of protection provided by enclosures (IP Code)” describes a system for classifying the degree of protection by the IP Code.
IP CodeIP (Ingress Protection) Code is a coding system to indicate the degree of protection provided by enclosure against access to hazardous parts, ingress of solid foreign objects, ingress of water and to give additional information in connection with such protection. There are several different uses of IP Codes, as described in IEC 529. IP Codes can have the following arrangement:
1. First character only, such as IP 3X2. Second character only, such as IP X4, or3. Both characters, such as IP 34
The first character indicates the degree of protection against the ingress of solid foreign objects. First character definitions are as follows:
0 - Non-protected1 - Protected against solid foreign objects of 50 mm diameter and greater2 - Protected against solid foreign objects of 12.5 mm diameter and greater3 - Protected against solid foreign objects of 2.5 mm diameter and greater4 - Protected against solid foreign objects of 1.0 mm diameter and greater5 - Dust-protected6 - Dust-tight
The second character of the IP Code indicates the degree of protection against the ingress of water with harmful effects. Second character definitions are as follows:
0 - Non-protected1 - Protected against vertically falling water drops2 - Protected against vertically falling water drops as the enclosure is tilted 15 degrees3 - Protected against spraying water4 - Protected against splashing water5 - Protected against water jetting6 - Protected against powerful water jetting7 - Protected against temporary immersion8 - Protected against continuous immersion
The higher protection classification always takes precedence over the lower classification. Example: an enclosure with IP 67 code:Totally protects persons against access to hazardous parts(tested with a wire of 1,0 mm diameter)Dust-tight enclosure, totally protects the equipment inside the enclosure against dust(tested with talcum powder in suspension in a closed test chamber under pressure)Waterproof enclosure, totally protects equipment inside the enclosure against water penetration(tested by completely immersing the enclosure in a water tank for 30 min. 1 m deep)
Note: IP rating will ONLy apply for properly installed equipment
IP CODEIP CODEE L E M E N T S A N D T H E I R M E A N I N G
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 131
www.ldpi-inc.com
Since many of LDPI’s components are made of plastic materials, their resistance against chemical products may be limited or even nil. Consult this list before using aggressive detergents, disinfectants, or installing the luminaire in chemically hazardous areas (such as car washes, swimming pools, industrial kitchens, industrial laundries, slaughterhouses, livestock containment facilities, etc...) or in case of doubt, please contact us. For these conditions, appropriate products (like stainless steel latches, etc...) are available.
WARNING: The information in this chart has been supplied to LDPI, Inc. by other sources and is to be used ONLY as a guide in selecting light fixtures for appropriate chemical compatibility. Before permanent installation, test the light fixture with the chemicals and under specific conditions of your application. Variations in chemical behavior/handling due to factors such as temperature, pressure and concentrations can cause failure even though it passed an initial test.
+ = Resistant+/- = Limited resistant- = Not resistant
In case of limited resistance to corrosion (+/-) the use of polycarbonate clips is not suggested.We do advise the use of stainless steel latches if there is any uncertainty.
CHEMICAL ACRYLIC POLYCARBONATE FIBERGLASS
ACIDS (Weak up to 10%) +/- + +
ACIDS Acetic (max 30%) - +/- + Hydrochloric (max 20%) + +/- +/- Nitric (max 20%) +/- +/- +/- Sulphuric (max 50%) +/- +/- - Phosphoric - +/- - Hydrobomic - - - Accumulator Acid +/- +/- +/-
BASES (Weak) Ammonia (max 25%) + - +
BASES (Concentrated) Ammonia (max 50%) +/- - +/- Sodium Hydroide +/- - -
SALT SOLUTIONS Common Salt + +/- + Metal Salt + +/- + Soda + +/- +
HyDROCARBONS Aliphatic +/- + +/- Aromatic - - +/- Parafins + + + Carbon Dioxide, Carbon Monoxide + + + Ethyl Acetate - - - Pyridine - - -
CHLORIDE HyDROCARBONS Carbon Tetrachloride - - +/- Trichlorethylene - - - Methylene Chloride - - -
ALCOHOLS Up to 30% +/- +/- + Concentrated - - +/- Methanol, Ethanol, Phenol - - +/-
ETHERS Ether +/- - +/- Petroleum Ether + +/- +/-
AROMATIC HyDROCARBONS Aniline +/- - +/- Benzene and derivates - - - Hydrogen Peroxide +/- +/- - Xylene - - -
OILS AND FATS Petrol, Kerosene +/- +/- + Mineral oil - +/- + Vegetable oils (hot) + - + Cooking fats (hot) + - +
UNSATURATED CHLORIDE HyDROCARBONS Chloroform - - -
CHEMICAL RESISTANCECHEMICAL RESISTANCEO F P L A S T I C S : 3 7 6 , 3 7 9 A N D 3 7 9 i S E R I E S
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012132
www.ldpi-inc.com
WARNING: The information in this chart has been supplied to LDPI, Inc. by other sources and is to be used ONLY as a guide in selecting light fixtures for appropriate chemical compatibility. Before permanent installation, test the light fixture with the chemicals and under specific conditions of your application. Variations in chemical behavior/handling due to factors such as temperature, pressure and concentrations can cause failure even though it passed an initial test.
LENS MATERIAL GASKET FIXTURE BODY
CHEMICALS
GLAS
S
ACRy
LIC (S
HEET
)
POLy
CARB
ONAT
E
NEOP
RENE
ALUM
INUM
Acetic Acid A D A D DAcetone A D D D AAluminum Chloride A A A A DAluminum Sulfate A A A A DAmmonium Nitrate A A D A BBoric Acid (10%) A A A A BBrake Fluid A D D D ACalcium Chloride A A A A CCarbon Tetrachloride A D D D AChlorine Water A A D A BCitric Acid A A A D DCutting Fluid A A A A DDistilled Water A A A A BEthyl Alcohol A D A A AEthylene Glycol A A A A AHydrolic Oil A A B D AHydrochloric Acid (25%) A A A B DIsopropyl Alcohol A A A A AKerosene A A B D ALiquid Soap A A A A BMethylene Chloride A D D D AMineral Spirits A A B D AMotor Oil A A A D ANitric Acid A A C D DPhosphoric Acid (25%) A A A A DPotassium Chloride (25%) A A A A CSea Water A A A A CSodium Chloride (25%) A A A A BSulfuric Acid (25%) A A A D DTanic Acid (10%) A A A A DToluene A D D D A Turpentine A A A D AUnleaded Gasoline A A D D AXylene A D D D A
A. Recommended Material for long term exposure.B. Satisfactory performance, functional after long term exposure, but cosmetic damage will occur.C. Short duration exposure only, subject to chemical attack and will deteriorate.D. Continuous exposure will cause deterioration of material. Cleaning recommended if used in area containing chemicals.
CHEMICAL RESISTANCECHEMICAL RESISTANCES P E C I F I C TO T H E 3 8 4 S E R I E S
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 133
www.ldpi-inc.com
Toll Free: 1-800-854-0021Fax: 715-839-8145
Web: http://www.ldpi-inc.comE-Mail: [email protected]
BOOTH / ROOM INFORMATIONInside dimensions of room/booth:
Width: Height: Depth:
Booth design: Down Draft Cross Draft Side Down Draft Dry Filter Water Wash
What kind of lights in booth:
Where are they mounted? (Wall, ceiling, hips, corners, combo etc...)
What kind of fixture access is needed? Inside Access Outside Access Both
Does existing booth have hipped ceiling? yes No If yes: Hip Size: Degree: If yes, are there lights in hip? yes No Is it possible to add lights to hip? yes No
Does booth have corner chambers? yes No If yes, size:
Is booth floor: Concrete Grating Combination
Dimensions of concrete area from booth wall to grating:
Materials used for booth construction: Floor: Color: Walls: Color: Ceiling: Color:
Are any of the walls/ceiling open? yes No
If yes, where?
Are there man doors in booth walls? yes No If yes, where?
Any windows or translucent panels? yes No If yes, where?
Description of type of fixture preferred: (i.e. 4 lamp, 4 ft. 32 watt T8)
FILTER INFORMATION
Where are filters located? Floor Ceiling Wall
What are the overall dimensions of the filtered area?
Length: Width:
OBJECT
Type of product:
Shape of product (i.e. square, cylinder, etc.)
Largest object:
Width: Height: Depth:
Smallest object:
Width: Height: Depth:
Color primarily painted?
OTHER CONSIDERATIONS
Indoor Outdoor Heated Unheated
Chemical Used for Wash:
Media Used for Blast:
Cure/Bake Process in Booth:
GOALS
Determine number of fixtures to obtain:
foot candles at (ft.) height.
Looking for approximate number of fixtures for booth/room.
COMMENTS:
All of the following information can influence light levels in a booth or room. Having thisinformation available will assist our territory reps in matching the right fixture to your application.
COMPANy NAME:
MAILING ADDRESS (LINE 1):
MAILING ADDRESS (LINE 2):
CITy: STATE:
ZIP: COUNTRy:
CONTACT:
PHONE:
FAX:
E-MAIL ADDRESS:
WEB ADDRESS:
**Please submit drawings if available.**
CALCULATION REQUESTCALCULATION REQUESTB O O T H / R O O M L I G H T I N G A P P L I C AT I O N F O R M
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012134
www.ldpi-inc.com
PROJECT INFORMATION:
Date:
Project Name:
Location:
Specifier:
Phone:
Agency:
Agent:
Date Required:
Type of Application:
Fixture Desired (Catalog Number):
Lamp Type:
Wattage:
Voltage:
Desired light levels in:
Footcandles:
or Lux:
Uniformity Requirements:
Average:
Max/Min:
Ave/Min:
Special Consideration: (i.e. obstructive elements, beams, other)
FIXTURE INFORMATION:
ROOM SIZE: (If not rectangular, send dimensional drawing)
Length:
Width:
Height:
If ceiling is sloped, what are the varying heights?
Where do they occur?
REFLECTANCES:
Ceiling: Color:
Walls: Color:
Floor: Color:
CALCULATION REQUESTCALCULATION REQUESTI N D O O R L I G H T I N G A P P L I C AT I O N F O R M
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 135
www.ldpi-inc.com
PROJECT INFORMATION:
Date:
Project Name:
Location:
Specifier:
Phone:
Agency:
Agent:
Date Required:
Type of Application:
***PARKING GARAGE DRAWING REQUIRED TO BE SENT IN WITH APPLICATION FORM***
Fixture Desired (Catalog Number):
Lamp Type:
Wattage:
Voltage:
Desired light levels in:
Footcandles:
or Lux:
Uniformity Requirements:
Average:
Max/Min:
Ave/Min:
Special Consideration: (i.e. obstructive elements, beams, other)
FIXTURE INFORMATION:
Ceiling Style: Deep Cell or “T” Flat
Ceiling Height:
Bottom of Cell:
Top of Cell:
Driving Lanes: One Way Two Way
CALCULATION REQUESTCALCULATION REQUESTPA R K I N G G A R A G E A P P L I C AT I O N F O R M
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012136
www.ldpi-inc.com
How Much Light is Needed?
Before undertaking any lighting retrofit project or designing a lighting system for a new facility, determine appropriate and adequate levels of illumination for required activities both inside and outside the facility. Take a close look at each area to see what the lighting needs really are. Ask people how they feel about the lighting: is there too much or too little light, is there glare?
If you want to check people’s impressions and your own, you can measure the amount of light with a light meter. your lighting supplier can probably lend you one. you can then compare your present lighting levels to nationally accepted recommendations. When measuring levels with a meter, be sure to take into account whatever contribution daylight is making. you need adequate lighting on overcast days and at night. In many cases, you will find present lighting levels are excessive and need adjustment, which are usually achieved through delamping or conversion to a different lighting system. The Illuminating Engineering Society (IES) recommendations for lighting levels for various activities are shown in this table.
Recommended Light Levels
Task Area FootcandlesPaint Booths 100 - 150Corridors/Stairways/Restrooms 10 - 20Storage Rooms 10 - 50Conference Rooms 20 - 50General Offices 50 - 100Drafting/Accounting 100 - 200Areas with VDTs 75Classrooms 50 - 75Cafeterias 50Gymnasiums 30 - 50Merchandising 30 - 150Manufacturing Assembly 50 - 500Parking Areas (uncovered) 1 - 2
RECOMMENDED LIGHTRECOMMENDED LIGHTF O O T C A N D L E S B Y A P P L I C AT I O N
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 137
www.ldpi-inc.com
Need a Custom or Special Fixture?LDPI, Inc. is an excellent source for that special needs custom lighting fixture.
LDPI, Inc. has the in-house engineering and manufacturing experts to handle most any need for Harsh or Hazardous Environments.
To have someone contact you for that special or custom need:email us at: [email protected] call our toll free number: 1-800-854-0021.
Examples of Custom Applications:
Paint BoothsInspection AreasWaste Water Treatment FacilitiesWarehousing Military ApplicationsLaboratoriesOil RefineriesOffshore RigsChemical PlantsBreweriesGrain HandlingFood ProcessingAmmunition ManufacturingCoal, Gold, Copper, Silver MiningPulp and Paper ManufacturingGeneral Manufacturing Plants
Steel Mills and FoundriesUtility Power PlantsMarine and Coastal FacilitiesAutomobile ManufacturingShipyards and Ship BuildingFlour, Sugar, Starch ProcessingPaint ManufacturingRubber ManufacturingAerospace FacilitiesAircraft ManufacturingAirplane HangersBoat Dry StackBoat Paintingand more...
CUSTOM APPLICATIONSCUSTOM APPLICATIONSL I G H T F I X T U R E C U S TO M I Z I N G O P T I O N S
376 Series: wet/damp inspection cart
Undercarriage inspection cart
229S Custom Fixture
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012138
www.ldpi-inc.com
ASK THE EXPERTHave you ever wanted a place to get that specific lighting question answered? Well, look no further!
LDPI, Inc. has all the right technical people in place to answer that Harsh, Hazardous or General lighting question.
To have someone respond to your specific question:email us at: [email protected] call us toll free at: 1-800-854-0021
FREQUENTLY ASKED QUESTIONS ABOUT LIGHTING
Why is a lamp’s CRI or CCT important?
The Color Rendering Index (CRI) is the reason that the shirt and pants you thought matched so well at home seem to clash in the restroom at work.The closer the CRI of a lamp is to 100, the more “true” it renders colors in the environment. For individuals, such as graphic artists who perform tasks that require color precision or discrimination, lamps with a high CRI are recommended. Full-spectrum lamps are available that offer a CRI of over 90.Warm and inviting are some of the words used to describe environments that contain lamps with a Correlated Color Temperature (CCT) of 3000K.Coffee shops, restaurants, and hotel lobbies are a few applications in which cozy lighting environments are desirable. Hospitals, cafeterias, classrooms, and conference rooms are areas where an image of neatness is important. Lamps that appear cool - measuring a CCT of 4100K - are most appropriate for these types of applications. By comparison, daylight measures 5000K, and neutral lamps have a CCT of 3500K.
What are the differentiating characteristics of incandescent, fluorescent, and high-intensity discharge (HID) lamps?
Incandescent lamps:· Appear “warm” in color and have excellent color rendering. · Are the least efficient of general lamp types due to the amount of energy
consumed heating the filament in order for the lamp to turn incandescent. · Have a short lamp life of between 500 and 3,000 hours. · Are easy to install because no ballast is required.
Fluorescent lamps:· Are available in a complete range of color combinations. · Produce low heat. · Require a more extensive installation because ballasts are a necessary part of the fixture.· Have an extremely long life of up to 24,000 hours. · Due to smaller sizes and screw base features, fluorescent can replace incandescent lamps.· Are energy efficient.
High-intensity discharge (HID) lamps:· Are ideal for large stores, warehouses, auditoriums, outdoor parking areas,
and applications where efficiency is a priority.· Have a warm-up period, which results in slower start-up.· Deliver a large amount of light over a wide area.· Have a long life of between 5,000 and 24,000 hours.· Require ballasts.
How do T12, T10, T8, and T5 fluorescent lamps differ?
These four lamps vary in diameter (ranging from 1.5 inches to 0.625 or five-eighths of an inch in diameter). Efficacy is another area that distinguishes one from another. T8 lamps offer a 5% increase in efficacy over 34-watt T12 lamps, and have become the most popular choice for new installations.
IES Classifications of Optical Refractor types:
TyPE I: Asymmetrical - long & narrow TyPE II: Asymmetrical TyPEIII: Asymmetrical TyPEIV: Asymmetrical - forward throw TyPE V: Symmetrical
For representational purposes only
ASK THE EXPERTASK THE EXPERTL I G H T F I X T U R E S A N D A P P L I C AT I O N S
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 139
www.ldpi-inc.com
Color rendering index (CRI) - a method for describing the effect of a light source on the color appearance of objects being illuminated, with a CRI of 100 representing the reference condition (and the maximum CRI possible). In general, a lower CRI indicates that some colors may appear unnatural when illuminated by a lamp.
Color temperature - see correlated color temperature.
Constant-wattage autotransformer (CWA) - the most common type of ballast used for HID lamps, it maintains a constant power (wattage) supply to the lamp when system input voltage fluctuates.
Correlated color temperature (CCT) - a description of the color appearance of a light source in terms of warmth or coolness, as measured on the Kelvin scale (K). As the temperature rises, the color appearance shifts from yellow to blue. Thus, lamps with a low CCT (3000K or less) have a yellow-white color appearance and are described as “warm”; lamps with a high CCT (4000K and higher) have a blue-white color appearance and are described as “cool”.
Ballast factor (BF) - the ratio of light output of a lamp operated by a given ballast to the light output of the same lamp when operated by a reference ballast. Lamps operated by a ballast with BF of 0.90 will provide 90 percent of their rated light output (lumens). BFs between 0.85 and 1.0 are the most common.
Disability glare - light that is relatively bright compared to the background, making vision measurably worse. The inability to see clearly as a result of the brightness of headlights from an oncoming car at night is an example.
Discomfort glare - the type of glare that is uncomfortable and distracting, yet less obvious than disability glare. A bright light source in an individual’s peripheral vision is an example.
Efficacy - the ratio of light output (lumens) to input power (watts) expressed in lumens per watt (LPW).
High pressure sodium (HPS) - a high-intensity discharge lamp type that uses sodium under high pressure as the primary light-producing element.
Illuminance - The amount of light that reaches a surface. Illuminance is measured in footcandles (lumens/square foot) or lux (lumens/square meter). One footcandle equals 10.76 lux, although for convenience the IESNA uses 10 lux as the equivalent.
Instant-start - a method of starting fluorescent lamps. The voltage, which is applied across the electrodes to strike the electric arc, is up to twice as high as it is with other starting methods. The higher voltage is necessary because the electrodes are not heated prior to starting.
Lamp life - the median life span of a very large number of lamps. Half of the lamps in a sample are likely to fail before the rated lamp life, and half are likely to survive beyond the rated lamp life.
Lamp lumen depreciation (LLD) - the reduction in lamp light output that progressively occurs during lamp life.
Lumen (lm) - a unit of measurement of the rate at which a lamp produces light. A lamp’s light output rating expresses the total amount of light emitted in all directions per unit time. Ratings of initial light output provided by manufacturers express the total light output after 100 hours of operation.
Luminance - the photometric quantity most closely associated with the perception of brightness, measured in units of luminous intensity (candelas) per unit area (feet squared or meters squared).
Luminaire efficiency - the ratio of the light emitted by luminaire to the light emitted by the lamp or lamps within it. Components of a luminaire, such as reflectors and diffusers, absorb some of the light from the lamps(s). A highly efficient luminaire emits most of the light that the lamp(s) emits.
Metal halide (MH) - a high-intensity discharge lamp type that uses mercury and several halide additives as light-producing elements.
Open-circuit voltage - the voltage applied across the output terminals of a ballast when no load is connected. This is the voltage applied across a lamp circuit to start a lamp. After starting, the voltage rapidly decreases and stabilizes at the operating voltage.
Preheat - a method of starting fluorescent lamps in which the electrodes are heated before a switch opens to allow a starting voltage to be applied across the lamp. With preheat starting, the lamp flashes on and off for a few seconds before staying lit.
Power factor - a measure of how effectively a ballast converts current and voltage into usable power to operate the lamps. A power factor of 0.9 or greater indicates a high power-factor ballast.
Prismatic lens - an optical component of a luminaire that is used to distribute the emitted light. It is usually a sheet of plastic with a pattern of pyramid-shaped refracting prisms on one side. Most ceiling mounted luminaries in commercial buildings use prismatic lenses.
Rapid-start - a method of starting fluorescent lamps in which the ballast supplies voltage to heat the lamp electrodes for one to two seconds prior to starting and, in most cases, during lamp operation. A rapid-start system starts smoothly, without flashing.
Reflected glare - often called veiling reflections, glare that results from light shining off polished or glossy surfaces.
Restrike time - the time required for a lamp to restrike, or start, after the lamp is extinguished. Normally, HID lamps need to cool before they can be restarted.
Visual comfort probability (VCP) - a system for estimating discomfort glare that predicts the percentage of people who are likely to find the lighting comfortable, against the percentage that find it uncomfortable.
ASK THE EXPERTASK THE EXPERTG L O S S A RY O F L I G H T I N G T E R M S
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012140
www.ldpi-inc.com
2224 Ft. 32W 4 Ft. 44W 4 Ft. 54W 8 Ft. 32W 8 Ft. 44W 8 Ft. 54W
229H32W 19# 1.95 Cu. Ft. 50”L x 15”W x 4.5”H 40W 19# 1.95 Cu. Ft. 50”L x 15”W x 4.5”H 44W 19# 1.95 Cu. Ft. 50”L x 15”W x 4.5”H 54W 19# 1.95 Cu. Ft. 50”L x 15”W x 4.5”H
2364 lamp 32W 26#4 lamp 54W 26#6 lamp 32W 30#6 lamp 54W 30#
2402 lamp 48# 3.96 Cu. Ft. 57”L x 15”W x 8”H3 lamp 59# 5.00 Cu. Ft. 57”L x 19”W x 8”H4 lamp 59# 5.00 Cu. Ft. 57”L x 19”W x 8”H5 lamp 71# 6.50 Cu. Ft. 57”L x 24 5/8”W x 8”H6 lamp 71# 6.50 Cu. Ft. 57”L x 24 5/8”W x 8”H
240 8 Ft. (4 Ft. or 8 Ft. lamps)2 lamp (8 Ft.)3 lamp (8 Ft.)4 lamp (4 or 8 Ft.)5 lamp (8 Ft.)6 lamp (4 or 8 Ft.)8 lamp (4 Ft.)10 lamp (4 Ft.)12 lamp (4 Ft.)
24132W 42# 3.56 Cu. Ft. 57”L x 18”W x 6”H40W 52# 3.56 Cu. Ft. 57”L x 18”W x 6”H44W 46# 3.56 Cu. Ft. 57”L x 18”W x 6”H54W 52# 3.56 Cu. Ft. 57”L x 18”W x 6”H60W 62# 3.56 Cu. Ft. 57”L x 18”W x 6”H
260/26132W 57# 4.39 Cu. Ft. 55”L x 23”W x 6”H40W 63# 4.39 Cu. Ft. 55”L x 23”W x 6”H60W 70# 4.39 Cu. Ft. 55”L x 23”W x 6”H
280/28159W 117# 11.98 Cu. Ft. 103.5”L x 25”W x 8”H86W 117# 11.98 Cu. Ft. 103.5”L x 25”W x 8”H95W 117# 11.98 Cu. Ft. 103.5”L x 25”W x 8”H110W 117# 11.98 Cu. Ft. 103.5”L x 25”W x 8”H
Slim Light390320 25# 3.40 Cu. Ft. 56”L x 21”W x 5”H390340 31# 3.40 Cu. Ft. 56”L x 21”W x 5”H390360 39# 4.05 Cu. Ft. 56”L x 25”W x 5”H360420 30# 3.40 Cu. Ft. 56”L x 21”W x 5”H390440 38# 3.40 Cu. Ft. 56”L x 21”W x 5”H390460 48# 4.05 Cu. Ft. 56”L x 25”W x 5”H
Shipping weights, volume and dimensions with packaging material.These measurements are subject to change and should be used as a guideline only.Packaging materials and packaging techniques may change subsequent to printing.For fixtures not listed please call us at 1-800-854-0021 for more information.
SHIPPING INFORMATIONSHIPPING INFORMATIONF O R L D P I , I N C . F I X T U R E S
400390421 36# 3.40 Cu. Ft. 56”L x 21”W x 5”H390441 42# 3.40 Cu. Ft. 56”L x 21”W x 5”H390461 53# 4.05 Cu. Ft. 56”L x 25”W x 5”H
440T/THO440T 44# 4.05 Cu. Ft. 56”L x 25”W x 5”H440THO 44# 4.05 Cu. Ft. 56”L x 25”W x 5”H
440 2x4440 2x4 48# 2.44 Cu. Ft. 47.75”L x 23.5”W x 3.94”H
Inspection39042LINS 48# 3.40 Cu. Ft. 56”L x 21”W x 5”H39082LINS 78# 3.57 Cu. Ft. 100”L x 21”W x 5”H
3802 Lamp 2 Ft. 33# 3.00 Cu. Ft. 36"L x 12"W x 12"H2 Lamp 4 Ft. 43# 4.69 Cu. Ft. 56.25"L x 12"W x 12"H2 Lamp 4 Ft. EM 60# 4.69 Cu. Ft. 56.25"L x 12"W x 12"H3 Lamp 4 Ft. 52# 9.38 Cu. Ft. 56.25"L x 12"W x 24"H4 Lamp 4 Ft. 84# 9.38 Cu. Ft. 56.25"L x 12"W x 24"H
3842 Ft. 23# .78 Cu. Ft. 50”L x 6.5”W x 6.3”H4 Ft. 32# 1.55 Cu. Ft. 26”L x 6.5”W x 6.3”H
Single Cart4346 4520 190#
Task Carts3668 3668H 3669 3669H
XP Cart4372-2 4372-3 4372-4
SERIES WEIGHT VOLUME L W H SERIES WEIGHT VOLUME L W H
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 141
www.ldpi-inc.com
LDPI, Inc. T-n-C OverviewORDERS:$200.00 minimum order required. All items must be ordered by their catalog number. Please specify voltage, wattage and any options sought.
CREDIT POLICIES:All requests for an open account (Net 30) are subject to credit approval. Customers must complete a credit application and allow at least one week for processing. To expedite your initial order, please send payment for full amount and include shipping and handling charges.
TERMS:Our standard terms: Net 30 days with prior approved credit. All accounts unpaid at maturity will be charged interest at a rate of 18% PER ANNUM. Subsequent orders will be shipped C.O.D. or prepay only.
DELIVERy:Standard shipping time is two weeks unless special arrangements are made prior to time of order.
FREIGHT:All shipments are F.O.B. LDPI's factory, located in Eau Claire, WI. We reserve the right to select the carrier on all shipments unless special arrangements are made at time of order. In addition to the purchase price the customer will be charged shipping and handling charges set forth on the invoice.
CLAIMS:All LDPI® merchandise is inspected prior to shipping. Our liability ceases upon acceptance of merchandise by the carrier. DO NOT DEDUCT for damaged merchandise when paying invoices, as carrier reimburses the consignee. Therefore, all claims must therefore be filed with the carrier at the time of receipt and noted on the Bill of Lading. We cannot accept freight claims if the Bill of Lading does not contain a notation of the existence of damage. We will assist in collecting your claim, but the liability for payment of the claim remains with the carrier.
RETURNS:Authorization must be obtained from LDPI prior to returning merchandise to us. A request for authorization to return material must be made within 60 days from the date of shipment. We will issue a RETURN MATERIAL AUTHORIZATION (RMA) NUMBER. Merchandise must be returned, freight prepaid, and in original factory cartons. A minimum restocking charge of 20% applies on returns. Only standard catalogued merchandise may be returned. Custom made and modified versions of our standard product are not subject to return. A minimum 50% restocking charge will apply, if standard merchandise is returned without a proper RMA.
PRICING:We make every effort to provide pricing information to you in a timely manner. However, prices and terms are subject to change without notice.
This Overview is not a substitute for the detailed Terms and Conditions.If there is a difference between this Overview and the detailed Terms and Conditions, the Terms and Conditions govern the relationship.See our website: http://ldpi-inc.com/legal/index.htm for our current Terms and Conditions.
LDPI INC.LDPI, INC.G E N E R A L T E R M S A N D C O N D I T I O N S O F S A L E
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012142
www.ldpi-inc.com
1. EXCLUSIVITY OF TERMS: These terms and conditions, together with any terms and conditions contained either on the front side of this document or any other purchase documents issued by us constitute the entire agreement of LDPI, Inc. (“Seller”) and the Buyer named on the front side (“Buyer”), and supersede all previous correspondence between Buyer and Seller, both written and oral, including any purchase orders that may have been submitted by the Buyer. Any term specified on the front side of this document supersedes any term on this side of the Agreement. This writing is not an acceptance of any offer made by Buyer and specifically rejects any additional or conflicting terms in Buyers acceptance documents which are deemed a material alteration and therefore rejected. Requests for change orders telephoned, mailed, emailed or faxed to Seller shall be considered written and approved by Buyer if Seller agrees to such change and commences engineering or production changes. These changes shall be binding even if Seller has not yet quoted an amount for the change. If quoted, the quoted amount shall be deemed accepted by Buyer. If not yet quoted, Seller shall be entitled to an equitable adjustment to price and delivery terms, not less than its standard shop rates and burden rates applicable to the Buyer in the base agreement.
2. PURCHASE PRICE: The purchase price is exclusive of any sales, use, excise, value added tax, custom or duty or any other fee imposed on or measured on the transaction regardless of type (“taxes”). Any taxes shall be paid by the Buyer. In the event that Seller shall be required to collect or pay any taxes, Buyer shall reimburse Seller for such taxes. Seller may invoice Buyer for any taxes, and add such amount to the purchase price unless a valid exemption certificate is provided by the Buyer. The purchase price shall be adjusted for change orders.
3. TERMS OF PAYMENT: Unless otherwise specified by the Seller, all prices are 30 days, net cash, subject to Seller’s approval of Buyer’s credit. If any payment is not made when due, Seller may impose interest on the unpaid balance of the purchase price (including change orders, taxes, freight and handling) at the rate of 18% PER ANNUM, unless such rate is prohibited by law, in which case, the highest rate permitted by law shall apply. Additionally, Buyer shall pay all costs of collection incurred by Seller, including reasonable attorneys’ fees. If Buyer fails to pay any sum when due under this Agreement, Seller may declare all payments owing under this Agreement and any other agreement with Buyer, to be immediately due and payable and may refuse to perform any obligations then remaining unperformed under this Agreement or any agreement with Buyer.
4. DELIVERY: Any term of delivery specified is tied to the date Seller receives Buyer’s signed copy of this Agreement, and is only an estimate. Seller does not guarantee the delivery date, but will make a good faith effort to do so. Seller may make partial shipments and submit a separate invoice for each shipment. Unless otherwise specified, all shipments will be F.O.B. Seller’s plant, Eau Claire, Wisconsin unless otherwise specified, delivery for shipment to Buyer of designs, shop drawings, equipment or materials to a carrier at Seller’s plant in Eau Claire, Wisconsin, shall constitute delivery by Seller to Buyer. All orders are shipped at Buyer’s risk and Seller shall incur no liability for any order damaged, broken or lost in transit. Seller shall not be liable for any failure to design, manufacture or deliver, or for any delay in the design, manufacture or delivery of, any order sold or to be sold by it if such a failure or delay or inability to obtain transportation, inability to obtain materials, shortage of fuel, failure of sources of suppliers, labor disputes, accident, riot, war, terrorist act, embargo, restraint or demand of the United States or of any other government, non-fulfillment by Buyer of conditions of payment, natural disaster, or any other cause beyond the control of Seller. If at any time Seller shall be prevented by any of the above causes from supplying all or any part of Buyer’s order and to its other customers under contract, Seller shall have the right to prorate the quantity then deliverable to Buyer and to its other customers.
5. ACCEPTANCE: Buyer shall be deemed to have accepted an order no later than 30 days following receipt unless it has previously notified Seller of any claim. All claims for damage in transit shall by submitted directly to the carrier and noted on the Bill of Lading prior to acceptance of the goods. If there is no notation made on the Bill of Lading, Seller cannot process a freight claim against the carrier. Therefore Buyer shall be deemed liable for any freight damage if the goods are accepted without notation of damage on the Bill of Lading.
6. SECURITy INTEREST: Buyer grants Seller a purchase money security interest in all unpaid goods (which shall serve as the collateral for this security agreement) and these goods shall remain personal property until the unpaid purchase price, and any costs, are paid in full. This purchase money security interest shall apply wherever these goods are located. By signing any quote, purchase order, request for purchase or quotation, order confirmation or contract, Buyer shall be deemed to have provided an authenticated signature under the Uniform Commercial Code (UCC) and these terms shall be deemed incorporated by reference into all such writings. Buyer shall allow Seller to file any financing statement evidencing this security interest and these terms shall be deemed by the parties to constitute a security agreement under the UCC. Until paid in full, Buyer shall not encumber, allow any lien to attach or convey the goods. Buyer shall be responsible for maintaining insurance on all unpaid goods for the invoice amount. In the event that the goods are not paid under the terms of Seller’s invoice such nonpayment shall act as a default and allow Seller the right to exercise its security interest in the collateral. In the event that the goods are affixed to real property Buyer acknowledges that Seller may file a mechanics lien against the property to which the goods are affixed.
7. INSTALLATION: This Agreement is limited solely to the transaction described on the front side, and Seller has no obligation to install the order. Buyer assumes all liability for installation of the order and shall be responsible for ensuring that the installation complies with federal, state and local health and safety laws and regulations. Buyer indemnifies, holds harmless, and agrees to defend Seller from any and all claims, damages, liabilities and expenses resulting from negligent installation of the order, installation that does not comply with such laws and regulations, or violation of any such law or regulation.
8. LIMITED WARRANTY: The Seller warrants to the Buyer that any order designed, manufactured and sold by the Seller, if properly installed, in an unmodified condition, in accordance with the installation instructions, operated, and maintained, and used under normal conditions, shall be free from defects in workmanship and materials for a period of one (1) year from the date the order is shipped from the facilities of the Seller. This warranty does not apply to orders manufactured by third parties or for any work or modifications performed by third parties. The obligations of the Seller, and the Buyer’s SOLE AND EXCLUSIVE REMEDY, shall be limited to one of the following, at the Seller’s option: (a) the repair or replacement of defective parts, provided, however, the Buyer shall be responsible for the payment of all labor costs associated with any such repair or replacement; or (b) in the event the Seller is unable to repair or replace the defective parts, the Buyer shall be entitled to a refund of the costs of the parts. The Seller shall have no obligation under this Limited Warranty for ordinary wear and tear, damage, improper installation or modification, improper or inadequate maintenance or inspection or if the order as used or installed does not comply with local, state, and federal laws or regulations. The Seller makes no warranty of any kind whatsoever with respect to parts which are manufactured or supplied by other persons or organizations (i.e. an OEM); provided, however, the Seller shall reasonably assist the Buyer in connection with warranties, if any, provided by an OEM.
LDPI INC.LDPI, INC.G E N E R A L T E R M S A N D C O N D I T I O N S O F S A L E
LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012 1-800-854-0021 www.ldpi-inc.com 143
www.ldpi-inc.com
We use our best effort to make our catalog accurate. We reserve the right to correct typographical errors and omissions. Specifications may be changed subsequent to printing.
9. WARRANTY PERFORMANCE PROCEDURE: All parts returned for repair, replacement, or refund (which refund may be in the form of a credit to the buyer's account), are subject to a minimum 20% restocking fee. A 50% restocking fee will apply if material is not accompanied with proper Return Materials Authorization (RMA) numbers. Request for authorization to return material must be made within 60 days from the date of shipment.
10. DISCLAIMERS OF WARRANTIES: THE WARRANTIES CONTAINED HEREIN ARE EXPRESSLY IN LIEU OF ANY OTHER EXPRESSED OR IMPLIEDWARRANTIES, OR ANY OTHER OBLIGATION ON THE PART OF THE SELLER, INCLUDING WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Any models, drawings, plans, specifications, affirmations of fact, promises or other communication by the Seller with reference to the order or the performance of the order are solely for the convenience of the Buyer and shall not in any way modify the expressed warranties and disclaimers set forth. No agents or other parties are authorized to make any warranties on behalf of the Company or to assume for the Company any other liability or obligation in connection with the order.
11. CONSEQUENTIAL DAMAGES: The Seller shall not be liable for any incidental or consequential damages arising from the order, the breach of any warranties, the failure to deliver, delay in delivery, delay on nonconforming condition, or for any other breach of contract or duty between Seller and Buyer. In no event shall the Seller’s total liability for any or all breaches of any warranty, exceed the actual purchase price paid by the Buyer for the equipment.
12. LIMITATIONS OF ACTIONS: Any action against the Seller must be commenced within one (1) year after the cause of action accrues.
13. MANUFACTURING DESIGNS AND PROPRIETARY PROPERTY: All copyrights, trademarks, plans, drawings, product designs, specifications, parts manuals, installation instructions, trade dress, and product ergonomics are the proprietary property of Seller (“Intellectual Property”). Buyer acknowledges Sellers investment in its Intellectual Property. Buyer represents and warrants that it is purchasing Seller’s product(s) in order to obtain Seller’s product(s) for its use, or resale for use, and will, either directly or through any third party, (i) respect Seller’s Intellectual Property as being the property of Seller, and (ii) not reverse engineer, pirate, copy, replicate in any other manner Seller’s product(s) or in any other way assist any other person in so doing.
14. CANCELLATIONS: Order cancellations will be subject to all expenses incurred by Seller including engineering costs, special parts purchased and production time. These expenses are the responsibility of the Buyer. If an order is cancelled after shipment is made or delivery is refused at destination, all costs for any and all further actions such as storage, rerouting or return shipment will be the responsibility of the Buyer. Any purchase order already in the manufacturing process will have a minimum of 25% value of order assessed to the Buyer or in any circumstance an amount established by Seller. No cancellation of a "Plans and Specifications:Special Order / Non-Catalog Item" will be allowed once acknowledged.
15. PLANS AND SPECIFICATIONS: Seller does not assume responsibility for orders shipped in accordance with the information supplied on or with Buyer orders in regards to Buyer approved drawings, non-standard fixture modification, lighting layout or custom designed application of product. Acceptance of any custom production item requires customer written authorization and signature.
16. BACKCHARGES: Seller will not approve or accept returns or back charges for labor, materials, or other costs incurred in modification, adjustment, service or repair of an order unless previously approved by Seller in writing.
17. CHANGES IN DESIGN: Seller reserves the right to modify the design and construction of the order to incorporate improvements or to substitute material equal or superior to that originally specified.
18. MISCELLANEOUS: All terms used herein, which are defined or given meaning in the Uniform Commercial Code, as adopted in the State of Wisconsin, and this Agreement, shall be governed by the laws of Wisconsin.
Form D-1046 Rev. 14APR11 © 2011, LDPI®, Inc.
LDPI INC.LDPI, INC.G E N E R A L T E R M S A N D C O N D I T I O N S O F S A L E
www.ldpi-inc.com 1-800-854-0021 LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc. 2012144
www.ldpi-inc.com
CATALOG INDEXCATALOG INDEXL D P I , I N C . L I G H T I N G C ATA L O G
FIXTURES BY SERIES
222 SERIES (General Industrial) .................................... PAGE: 5
229H SERIES (General Industrial) ................................. PAGE: 7
236 SERIES (High Bay) ................................................. PAGE: 9
240 SERIES (Vapor/Dust) .............................................. PAGE: 11
240 8 Ft. SERIES (Vapor/Dust) ...................................... PAGE: 13
241 SERIES (Vapor/Dust) .............................................. PAGE: 15
260/261 SERIES (Vapor/Dust) ....................................... PAGE: 17
280/281 SERIES (Vapor/Dust) ....................................... PAGE: 19
SLIM LIGHT SERIES (Paint Booth) ............................... PAGE: 21
400 SERIES (Rear Access Vapor/Dust) ......................... PAGE: 23
440 T/THO SERIES (Troffer Vapor/Dust) ....................... PAGE: 25
440 2x4 SERIES (Troffer Vapor/Dust) ............................ PAGE: 27
376 SERIES (Wet/Damp) ............................................... PAGE: 29
379 SERIES (Wet/Damp) ............................................... PAGE: 31
379i SERIES (Wet/Damp) .............................................. PAGE: 33
380 SERIES (Explosion Proof) ....................................... PAGE: 35
381 SERIES (Vapor Proof) ............................................. PAGE: 39
383 SERIES (Explosion Proof Incandescent) ................ PAGE: 41
384 SERIES (Marine/Wet) .............................................. PAGE: 43
387 SERIES (CFL/HID Vapor Proof) .............................. PAGE: 45
INDUCTION SERIES ..................................................... PAGE: 47
HID H/H2 SERIES (Hazardous) ..................................... PAGE: 49
HID XP/XP2 SERIES (Explosion Proof) ......................... PAGE: 61
HID FL SERIES (Flood) .................................................. PAGE: 71
CFL SERIES (Compact Fluorescent) ............................. PAGE: 73
INSPECTION SERIES
INSPECTION SERIES ................................................... PAGE: 77
INSPECTION MOUNTING AND TUNNEL ..................... PAGE: 79
INS2 INSPECTION SERIES .......................................... PAGE: 81
PORTABLE LIGHTING
SINGLE TASK/INSPECTION CARTS ............................ PAGE: 83
TASK/INSPECTION CARTS .......................................... PAGE: 84
EXPLOSION PROOF CARTS ........................................ PAGE: 85
MOUNTING & PHOTOMETRICS
MOUNTING .................................................................... PAGE: 87BOOTH CORNER/HIP MOUNT ..................................... PAGE: 93PHOTOMETRICS ........................................................... PAGE: 99
LAMPS, BALLASTS & LENS PROTECTION
FLUORESCENT LAMPS ................................................ PAGE: 122H.I.D. LAMPS ................................................................ PAGE: 123INCANDESCENT LAMPS .............................................. PAGE: 123BALLASTS ..................................................................... PAGE: 124FIXTURE LENS PROTECTION ..................................... PAGE: 125
INFORMATION
HAZARDOUS LOCATION FUNDAMENTALS ................ PAGE: 126IP CODE ......................................................................... PAGE: 130CHEMICAL RESISTANCE ............................................. PAGE: 131LIGHT CALCULATION REQUEST FORM ..................... PAGE: 133INDOOR LIGHTING APPLICATION FORM ................... PAGE: 134PARKING GARAGE APPLICATION FORM ................... PAGE: 135RECOMMENDED LIGHT LEVELS ................................ PAGE: 136CUSTOM APPLICATIONS ............................................. PAGE: 137ASK THE EXPERT ......................................................... PAGE: 138SHIPPING INFORMATION ............................................ PAGE: 140GENERAL T & C OF SALE ............................................ PAGE: 141INDEX ............................................................................. PAGE: 144
LDPI, Inc.4404 Anderson DriveEau Claire, WI 54703
Fax: 715-839-8145Web: www.ldpi-inc.com
E-Mail: [email protected]
Toll-Free 1-800-854-0021
Form D-1026 REV: 18JUL13LDPI® is a registered trademark of LDPI, Inc.© 2013 LDPI, Inc. All rights reserved
LDPI, Inc. has established itself as a nationally recognized leader inthe manufacture and supply of high quality, specialized lighting for