Uncontrolled static discharges can cause massive explosions and fires. Eltex ground monitoring systems are used for filling or pouring potentially explosive materials. The systems reliably and effectively ground any resulting electrostatic charges away.

The ground monitoring systems monitor the connection for potential equalization and the contact of the ground clamps. This function switches a potential-free changeover contact which can control visual or audible signal trans-mitters, interlocks, pumps, slides, etc.

Electrostatic charges when handling liquids, granulates and powders

Filling and emptying tanks with liquids, granulates and powders and pumping, stirring, mixing or spraying liquids as well as measuring and taking samples or cleaning tasks: All of these processes can cause a dangerous build-up of charge in liquids, granulates and powders or the insides of containers. The resulting amount and size of the charge depend on several factors. These include the properties of the media and their flow rate, the respective operating method as well as the size, geometry and material composition of the container.

Uncontrolled discharge is a danger that is not to be underestimated!

Page 3: innovatoi ns Keeping static problems earthed The Eltex

Terracompact II

1 2 3 4 5 6– +

N.O. COM N.C.

24V DC ±10%

7 8 9 10 11 12PAL

input Ex i

PAL ZG2 Z2 ZG1Z1

TERRABOX

TERRAPHARM

TERRACAP

Terracompact II

1 2 3 4 5 6– +

N.O. COM N.C.

24V DC ±10%

7 8 9 10 11 12PAL

input Ex i

PAL ZG2 Z2 ZG1Z1

Terracompact II

1 2 3 4 5 6– +

N.O. COM N.C.

24V DC ±10%

7 8 9 10 11 12PAL

input Ex i

PAL ZG2 Z2 ZG1Z1

Terracompact II

1 2 3 4 5 6– +

N.O. COM N.C.

24V DC ±10%

7 8 9 10 11 12PAL

input Ex i

PAL ZG2 Z2 ZG1Z1

Terracompact II

1 2 3 4 5 6– +

N.O. COM N.C.

24V DC ±10%

7 8 9 10 11 12PAL

input Ex i

PAL ZG2 Z2 ZG1Z1

Terrapharm

Ground clampsAlong with the Eltex TERRA-CONTROL TUE30 ground monitoring system, the Eltex series 70 of ground clamps guarantee that ground connections are established and reliably monitored.

Rewinding cable reels

The Eltex 601KR series of rewinding cable reels rewind the grounding cable easily after use, which protects it from damage and stores it in a safe place. The 601KR/AW rewinding cable reel is made of impact-resistant aluminum and is mounted to a mounting bracket so that it can swivel.

A durable plastic housing surrounds the 601KR/KW rewinding cable reel; the cable outlet is equipped with four rollers for guiding cables more easily. Both rewinding cable rollers are designed for wall mounting and can be used in EX zone 1 where there is a risk of explosion.

Effectively conducting electrostatic charges

Hazardous area (Ex zone 1)

Ground clamps

Rewinding cable reel 601KR/KW

Rewinding cable reel 601KR/AW

Page 4: innovatoi ns Keeping static problems earthed The Eltex

electrostatic innovations

Terracompact II

1 2 3 4 5 6– +

N.O. COM N.C.

24V DC ±10%

7 8 9 10 11 12PAL

input Ex i

PAL ZG2 Z2 ZG1Z1

TERRACOMPACT II

grounding

TERRa-ConTRol TUE30 The modularly designed ground monitoring system is available in two versions. The first is the standard module, TERRACOMPACT II TO030, for assembly on a standard rail NS35 in a control cabinet or a control room. The second version, the TERRABOX TCB030 or the TERRAPHARM, in a self-contained enclosure for wall mounting directly inside a hazardous area (Ex zone 1).

TERRaCaPThe TERRACAP TCB040 grounding system identifies a low-resistance connection using the jaws of the clamp. If a connection is identified, the device discharges electrostatic charges safely via a resistor, which prevents spark discharge. The control unit then checks the capacity detected at the clamp. If the capacity for the truck tank is correct, a green display lights up and the inter-locking relay enables the pumping process. The device then forms a low-resistance connection to the ground, which prevents further build-up of electrostatic charges. The connection using the clamps is continuously monitored during pumping.

Systematic ground monitoring

TCT function test unit for testing the correct function of the TERRACAP TCB040 grounding system

Hazardous area (Ex zone 1) Safe area

TERRaCoMPaCT II and TERRaBoX Each of the two grounding components are provided for connecting to a ground clamp or a rewinding cable reel with ground clamp. A two-clamp solution is also available for Big Bag grounding.

TERRaPHaRMThe Eltex TERRAPHARM grounding device combines proven TERRABOX technology with the specific material requirements of the pharmaceutical industry.

TCS keyswitch for switching the measuring circuit from capacitive to resistive measurement

Page 5: innovatoi ns Keeping static problems earthed The Eltex

Perfect performance – broad range of applications

grounding

Big bag applications for filling

Active grounding for tanker trucks

Active grounding for containers or drums

Process assurance with Eltex grounding devices in the pharmaceutical industry

When handling highly inflammable materials, uncontrolled static discharges are a hazard which must not be underestima-ted. It can cause explosions, fires and secondary accidents due to the effects of static shock. Controlled grounding is a safe and easy measure for protecting people, production facilities and transport machines. Grounding with static monitoring systems is particularly helpful in the following applications:

Loading and unloading tanker trucks Explosion protection in production Securing big bags Filling and emptying containers Process assurance in the pharmaceutical industry

Page 6: innovatoi ns Keeping static problems earthed The Eltex

electrostatic innovations

www.eltex.com

Exciting questionsAre you interested in Eltex grounding systems? Then don‘t delay; contact us. We would also be happy to introduce you to our numerous other innovative electrostatic Eltex solutions and show you customized options in detail that are already successfully in use. Find out for yourself how Eltex stays close to its customers and provides outstanding service.

To us, „special“ is normal The open exchange of information leads to individually tailored and customer-specific solutions. Joint problem analysis, rough and detailed planning, state-of-the-art product manufacturing as well as integration in existing systems, commissioning, maintenance and service accompany each of our products. The result is innovative and customer-oriented solutions.

Elte

x-El

ektr

osta

tik-

Ges

ells

chaf

t mbH

| Bl

auen

stra

ße 6

7–69

| 79

576

Wei

l am

Rhe

in |

Ger

man

yPh

one

+49

7621

79

05-

422

| Fa

x +4

9 76

21 7

9 0

5-33

0 |

info

@el

tex.

com