Inspection Snapshot Inspection ID: 625073 Inspection Time: 08:08 AM - 04:58 PM Inspection Start Date: 10/17/2018 Inspection End Date: 10/22/2018 Property ID: NY005011630 Property Type: Public Housing Property Name: WYCKOFF GARDENS Inspection State: Successful Score: 66c Inspection Summary Report (POA) for Inspection #625073 Report generation date/time: 10/23/2018 01:55 AM Score Version: 1 Page: 1 of 47 Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: [email protected] Type Building Units Expected Actual

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Inspection Snapshot

Inspection ID: 625073 Inspection Time: 08:08 AM - 04:58 PM

Inspection StartDate: 10/17/2018

Inspection EndDate: 10/22/2018

Property ID: NY005011630 Property Type: Public Housing

Property Name: WYCKOFF GARDENS

Inspection State: Successful Score: 66c

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 1 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 2: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Property Profile

Property Name: WYCKOFF GARDENSScattered Site? No Multiple Site? No

Address Line 1: 185 NEVINS Street

Address Line 2:City: BROOKLYN State: NY

ZIP: 11217 Extension: ____

Phone: (718) 855-9363 Extension:Fax: (718) 522-3288 Email: [email protected]

Type

Building Units

Expected Actual Sampled Expected Actual Sampled

Residential 6 5 5 1027 1027 26

Common 0 - - -

Total 6 5 5 1027 1027 26

Occupancy InformationNo. of Occupied Units Occupancy Rate Inspect Vacant Units

1014 99% No

Comments

Bedbug units bldg 1 unit 18h, bldg 5 unit 4u. 272 Wyckoff street bldg boiler rm totally offlineunder construction, 2 visible trailers with portable boilers outside bldg. Rest of basement isinspectable.. Flat roofs were inspected

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 2 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 3: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Participant Profile

Executive Director [Primary Contact / Not Present During Inspection]Name (F, MI, L): RODNEY DAVISOrganization: NEW YORK CITY HOUSING AUTHORITYAddress Line 1: 816 ASHFORD STREETAddress Line 2:City: BROOKLYN State: NY

ZIP: 11207 Extension:Phone: (718) 491-6967 Extension:Fax: (718) 922-4087 Email: [email protected]

Management Agent [Present During Inspection]Name (F, MI, L): ALVERISTA HALLOrganization: NEW YORK CITY HOUSING AUTHORITYAddress Line 1: 816 ASHFORD STREETAddress Line 2:City: BROOKYLN State: NY

ZIP: 11207 Extension:Phone: (718) 491-6967 Extension:Fax: (718) 922-4087 Email: [email protected]

Site Manager [Present During Inspection]Name (F, MI, L): SHELISA REIDOrganization: NEW YORK CITY HOUSING AUTHORITYAddress Line 1: 185 NEVINS STREETAddress Line 2:City: BROOKLYN State: NJ

ZIP: 11217 Extension:Phone: (718) 855-9363 Extension:Fax: (718) 522-3288 Email: [email protected]

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 3 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 4: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Score Summary

AreaPossiblePoints

Deductions(ExcludingH&S)

Pre H&SPoints

H&SDeductions

Final Points

Site 15.21 0.00 15.21 4.75 10.46Building Exterior 16.90 7.44 9.46 2.21 7.25Building Systems 22.46 0.76 21.69 0.00 21.69Common Area 9.46 5.57 3.90 1.94 1.95Unit 35.97 6.91 29.06 4.89 24.17Total 100.00 20.68 79.32 13.80 65.52

Score Version: 1 Score Date: 10/23/2018 Final Score: 66c

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 4 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 5: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Health & Safety Summary

Site Buildings Units Total

Non-Life Threatening (NLT)

Actual 1 2 6 9

Projected 1 2 237 240

Life Threatening (LT)

Actual 0 2 5 7

Projected 0 2 198 200

Smoke Detectors (SD)

Actual 0 0 0 0

Projected 0 0 0 0

Overall

Actual 1 4 11 16

Projected 1 4 435 440

Health and Safety Narrative1 site, 5 buildings and 26 units were inspected.

16 health and safety deficiencies(HSD) wereobserved.

Percentage Inspected:Site (PIS): 100%Building (PIB): 100%Unit (PIU): 3%

Projected HSD:Site = (Actual HSDS) / PISBuilding = (Actual HSDB) / PIBUnit = (Actual HSDU) / PIU

If all buildings and units were inspected, it isprojected that a total of 440 health and safetydeficiencies would apply to the property.

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 5 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 6: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Systemic Deficiencies

Type Area Item DeficiencyB/U withdefects

TotalB/U %

Capital Unit Kitchen Items Unit - Refrigerator - Missing/Damaged/Inoperable (Kitchen)

9 26 35

Ordinary Site Hazards HS - Sharp Edges (Hazards) 1 1 100

Ordinary CA Ceiling CA - Peeling/Needs Paint (Ceiling) 2 5 40

Ordinary CA Floors CA - Peeling/Needs Paint (Floors) 4 5 80

Ordinary CA Windows CA - Cracked/Broken/Missing Panes(Windows)

2 5 40

Ordinary CA Ceiling CA - Peeling/Needs Paint (Ceiling) 4 5 80

Ordinary CA Doors CA - Damaged Hardware/Locks(Doors)

3 5 60

Ordinary CA Walls CA - Peeling/Needs Paint (Walls) 3 5 60

Ordinary CA Floors CA - Peeling/Needs Paint (Floors) 2 5 40

Ordinary CA Walls CA - Peeling/Needs Paint (Walls) 2 5 40

Ordinary CA Walls CA - Peeling/Needs Paint (Walls) 2 5 40

Ordinary CA Ceiling CA - Peeling/Needs Paint (Ceiling) 2 5 40

Ordinary CA Walls CA - Damaged (Walls) 2 5 40

Note:B/U - Indicates Buildings or Units

BE - Indicates Building Exterior

BS - Indicates Building Systems

CA - Indicates Common Areas

Capital items are repairs that generally require large cash outlays. (Items such as new roofs and new appliances)

Ordinary items are repairs that require smaller cash outlays. (Items such as light fixtures, fire extinguishers and smoke detectors)

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 6 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 7: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Building/Unit Summary

Entity Expected Actual # Inspected # Reported Uninspectable

Building 6 5 5 0

Unit 1027 1027 26 6

Building 163001 - WYCKOFF GARGENS [ Sample , Inspected ]

Address Line 1: 130 THIRD AVENUE

Address Line 2:City: BROOKLYN State: NY

Zip: 11217 Extension: ____

Type Constructed In Floors Expected Unit CountActual Unit

Count

Elevator Structure 1966 21 175 175

Comments: Flat roofs were inspected

Unit # # Bedrooms Occupied?UnInspectedReason?

1J 5 Bedrooms Yes

5K 2 Bedrooms Yes

9J 2 Bedrooms Yes

13J 1 Bedroom Yes

19D 2 Bedrooms Yes

Building 163002 - 185 WYCKOFF GARDENS [ Sample , Inspected ]

Address Line 1: 185 NEVINS STREET

Address Line 2:City: BROOKLYN State: NY

Zip: 11217 Extension: ____

Type Constructed In Floors Expected Unit CountActual Unit

Count

Elevator Structure 1966 21 173 173

Comments: Flat roofs were inspected

Unit # # Bedrooms Occupied?UnInspectedReason?

1J 5 Bedrooms Yes

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 7 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 8: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

5K 2 Bedrooms Yes

9J 2 Bedrooms Yes

11A 1 Bedroom Yes

13 J 1 Bedroom Yes No Access

17G 4 Bedrooms Yes No Access

19D 2 Bedrooms Yes

Building 163003 - 272 WYCKOFF GARDENS [ Sample , Inspected ]

Address Line 1: 272 WYCKOFF STREET

Address Line 2:City: BROOKLYN State: NY

Zip: 11217 Extension: ____

Type Constructed In Floors Expected Unit CountActual Unit

Count

Elevator Structure 1966 21 180 180

Comments: Flat roofs were inspected

Unit # # Bedrooms Occupied?UnInspectedReason?

4E 2 Bedrooms Yes

4G 3 Bedrooms No Vacant

8G 3 Bedrooms Yes

11E 2 Bedrooms Yes

12 F 3 Bedrooms Yes No Access

16K 1 Bedroom Yes

Building 196001 - WARREN STREET [ Sample , Inspected ]

Address Line 1: 572 WARREN STREET

Address Line 2:City: BROOKLYN State: NY

Zip: 11217 Extension: ____

Type Constructed In Floors Expected Unit CountActual Unit

Count

Elevator Structure 1972 6 200 200

Comments: Flat roofs were inspected

Unit # # Bedrooms Occupied? UnInspected

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 8 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 9: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Reason?

3C 3 Bedrooms Yes

5M 2 Bedrooms Yes

2 O 1 Bedroom Yes

4L 0 Bedroom Yes

6J 0 Bedroom Yes

Building 256001 - ATLANTIC TERMINAL [ Sample , Inspected ]

Address Line 1: 487 CARLTON AVENUE

Address Line 2:City: BROOKLYN State: NY

Zip: 11238 Extension: ____

Type Constructed In Floors Expected Unit CountActual Unit

Count

Elevator Structure 1976 31 299 299

Comments: Flat roofs were inspected

Unit # # Bedrooms Occupied?UnInspectedReason?

4H 2 Bedrooms Yes

8C 3 Bedrooms Yes No Access

10 F 0 Bedroom Yes No Access

11K 4 Bedrooms Yes

15E 0 Bedroom Yes

19A 1 Bedroom Yes

19C 3 Bedrooms Yes

22H 2 Bedrooms Yes

26D 1 Bedroom Yes

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 9 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 10: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Certificates

Certificate Item Certificate State

Boilers No - This certificate cannot be provided or is expired

Elevators Yes - This certificate is provided or is not expired

Fire Alarms Yes - This certificate is provided or is not expired

Lead-Based Paint Disclosure Forms Yes - This certificate is provided or is not expired

Lead-Based Paint Inspection Reports No - This certificate cannot be provided or is expired

Sprinkler Systems Yes - This certificate is provided or is not expired

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 10 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 11: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Score Details

Note: The inspection software allows for the recording of the same deficiency as many times as it occurs. However, it is only scored once.

The number within the parenthesis after the Deficiency indicates the number of observations for this inspectable area. For example; "Site -

Spalling (Walkway / Steps) (4)" indicates the deficiency was observed and recorded 4 times under Site. Each individual observation can be

found in the Deficiency Details section of this report.

Item Deficiency SeverityPoints

DeductedPoints

Received

Site - WYCKOFF GARDENS - Site(0) [Possible Points : 15.21]

Health And Safety Deficiencies

Hazards HS - Sharp Edges (Hazards) (NLT ) Level 3 4.75

4.75 10.46

Building 163001 - WYCKOFF GARGENS - Common Areas [Possible Points : 1.52]

Non-Health And Safety Deficiencies

Ceiling CA - Peeling/Needs Paint (Ceiling) Level 1 0.02

Ceiling CA - Peeling/Needs Paint (Ceiling) Level 1 0.04

Ceiling CA - Peeling/Needs Paint (Ceiling) Level 2 0.04

Ceiling CA - Peeling/Needs Paint (Ceiling) Level 2 0.04

Doors CA - Damaged Hardware/Locks (Doors) (2) Level 1 0.10

Floors CA - Mold/Mildew/Water Stains/Water Damage(Floors)

Level 2 0.11

Floors CA - Peeling/Needs Paint (Floors) Level 1 0.02

Floors CA - Peeling/Needs Paint (Floors) Level 1 0.02

Floors CA - Peeling/Needs Paint (Floors) Level 1 0.04

Walls CA - Damaged (Walls) Level 1 0.10

Walls CA - Peeling/Needs Paint (Walls) Level 2 0.04

Walls CA - Peeling/Needs Paint (Walls) (2) Level 1 0.02

0.59 0.93

Building 163001 - WYCKOFF GARGENS - Unit 1J* [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Bathroom Items Unit - Water Closet/Toilet-Damaged/Clogged/Missing (Bathroom)

Level 2 0.57

Walls Unit - Mold/Mildew/Water Stains/Water Damage(Walls)

Level 1 0.02

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 11 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 12: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Deficiency SeverityPoints

DeductedPoints

Received

Walls Unit - Peeling/Needs Paint (Walls) Level 1 0.01

Windows Unit- Missing/Deteriorated Caulking/Seals/GlazingCompound (Windows)

Level 3 0.34

Health And Safety Deficiencies

Emergency/FireExits

HS - Emergency/Fire Exits Blocked/Unusable(Emergency/Fire Exits) (3) (LT )

Level 3 1.14

Infestation HS - Insects / roaches (Infestation) (NLT ) Level 3 0.51

* The point deductions for this sub-area exceed the number of possible points. The points received cannot be negative so it is set to zero. 2.59 0.00

Building 163001 - WYCKOFF GARGENS - Unit 5K [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Ceiling Unit - Peeling/Needs Paint (Ceiling) Level 1 0.01

Doors Unit - Damaged Surface (Holes/Paint/Rust/Glass)(Doors)

Level 3 0.15

Kitchen Items Unit - Refrigerator - Missing/Damaged/Inoperable(Kitchen)

Level 1 0.13

Walls Unit - Peeling/Needs Paint (Walls) Level 2 0.02

Health And Safety Deficiencies

Windows Unit - Inoperable/Not Lockable (Windows) (NLT ) Level 3 0.15

0.46 0.94

Building 163001 - WYCKOFF GARGENS - Unit 9J [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Doors Unit - Damaged Surface (Holes/Paint/Rust/Glass)(Doors)

Level 3 0.15

Kitchen Items Unit - Refrigerator - Missing/Damaged/Inoperable(Kitchen)

Level 1 0.13

0.28 1.11

Building 163001 - WYCKOFF GARGENS - Unit 19D [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Ceiling Unit - Mold/Mildew/Water Stains/Water Damage(Ceiling)

Level 3 0.08

Walls Unit - Mold/Mildew/Water Stains/Water Damage(Walls) (2)

Level 3 0.08

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 12 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 13: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Deficiency SeverityPoints

DeductedPoints

Received

Windows Unit- Missing/Deteriorated Caulking/Seals/GlazingCompound (Windows)

Level 3 0.34

Health And Safety Deficiencies

Air Quality HS - Mold and/or Mildew Observed (Air Quality) (2)(NLT )

Level 3 0.51

1.00 0.39

Building 163002 - 185 WYCKOFF GARDENS - Building Exterior* [Possible Points : 2.85]

Non-Health And Safety Deficiencies

Walls BE- Missing Pieces/Holes/Spalling (Walls) Level 2 0.64

Health And Safety Deficiencies

Emergency/FireExits

HS - Emergency/Fire Exits Blocked/Unusable(Emergency/Fire Exits) (LT )

Level 3 2.62

* The point deductions for this sub-area exceed the number of possible points. The points received cannot be negative so it is set to zero. 3.26 0.00

Building 163002 - 185 WYCKOFF GARDENS - Common Areas* [Possible Points : 1.86]

Non-Health And Safety Deficiencies

Ceiling CA - Peeling/Needs Paint (Ceiling) Level 1 0.02

Chutes CA - Damaged/Missing Components (Chutes) Level 2 0.19

Doors CA - Damaged Hardware/Locks (Doors) Level 1 0.10

Doors CA - Damaged Hardware/Locks (Doors) Level 2 0.19

Doors CA - Damaged Hardware/Locks (Doors) (2) Level 3 0.76

Doors CA - Damaged Surface (Holes/Paint/Rust/Glass)(Doors)

Level 3 0.76

Floors CA - Peeling/Needs Paint (Floors) (2) Level 2 0.08

Graffiti CA - Graffiti Level 1 0.25

Lighting CA - Missing/Damaged/Inoperable Fixture (Lighting) Level 2 0.25

Walls CA - Peeling/Needs Paint (Walls) (6) Level 2 0.04

Windows CA - Cracked/Broken/Missing Panes (Windows) Level 1 0.19

* The point deductions for this sub-area exceed the number of possible points. The points received cannot be negative so it is set to zero. 2.84 0.00

Building 163002 - 185 WYCKOFF GARDENS - Unit 1J [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Bathroom Items Unit - Lavatory Sink - Damaged/Missing (Bathroom) Level 1 0.13

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 13 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 14: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Deficiency SeverityPoints

DeductedPoints

Received

Bathroom Items Unit - Shower/Tub - Damaged/Missing (Bathroom) Level 1 0.17

0.30 1.10

Building 163002 - 185 WYCKOFF GARDENS - Unit 5K [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Kitchen Items Unit - Range/Stove- Missing/Damaged/Inoperable(Kitchen)

Level 3 0.51

Kitchen Items Unit - Refrigerator - Missing/Damaged/Inoperable(Kitchen)

Level 1 0.13

0.64 0.76

Building 163002 - 185 WYCKOFF GARDENS - Unit 9J [Possible Points : 1.24]

Non-Health And Safety Deficiencies

Doors Unit - Damaged Hardware/Locks (Doors) Level 1 0.04

Walls Unit - Peeling/Needs Paint (Walls) Level 1 0.01

Windows Unit- Missing/Deteriorated Caulking/Seals/GlazingCompound (Windows)

Level 3 0.34

0.39 0.86

Building 163002 - 185 WYCKOFF GARDENS - Unit 11A [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Ceiling Unit - Holes/Missing Tiles/Panels/Cracks (Ceiling) Level 2 0.09

Ceiling Unit - Mold/Mildew/Water Stains/Water Damage(Ceiling)

Level 1 0.02

0.11 1.29

Building 163002 - 185 WYCKOFF GARDENS - Unit 19D [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Walls Unit - Damaged/Deteriorated Trim (Walls Level 1 0.01

Windows Unit- Missing/Deteriorated Caulking/Seals/GlazingCompound (Windows)

Level 3 0.34

0.35 1.05

Building 163003 - 272 WYCKOFF GARDENS - Building Exterior [Possible Points : 2.96]

Non-Health And Safety Deficiencies

Doors BE - Damaged Surface (Holes/Paint/Rust/Glass) Level 3 1.63

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 14 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 15: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Deficiency SeverityPoints

DeductedPoints

Received

(Doors)

Walls BE- Stained/Peeling/Needs Paint (Walls) Level 1 0.25

1.88 1.08

Building 163003 - 272 WYCKOFF GARDENS - Common Areas [Possible Points : 2.03]

Non-Health And Safety Deficiencies

Ceiling CA - Peeling/Needs Paint (Ceiling) Level 1 0.02

Ceiling CA - Peeling/Needs Paint (Ceiling) Level 1 0.04

Doors CA - Damaged Hardware/Locks (Doors) Level 1 0.10

Floors CA - Peeling/Needs Paint (Floors) (2) Level 2 0.08

Walls CA - Damaged (Walls) Level 1 0.19

Walls CA - Damaged (Walls) Level 2 0.19

Walls CA - Peeling/Needs Paint (Walls) (5) Level 1 0.02

Windows CA - Damaged/Missing Screens (Windows) Level 1 0.05

Health And Safety Deficiencies

Doors CA - Damaged Frames/Threshold/Lintels/Trim(Doors) (NLT )

Level 3 0.42

Emergency/FireExits

HS - Emergency/Fire Exits Blocked/Unusable(Emergency/Fire Exits) (LT )

Level 3 0.76

1.88 0.15

Building 163003 - 272 WYCKOFF GARDENS - Unit 4E [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Kitchen Items Unit - Refrigerator - Missing/Damaged/Inoperable(Kitchen)

Level 1 0.13

Walls Unit - Peeling/Needs Paint (Walls) Level 1 0.01

0.14 1.26

Building 163003 - 272 WYCKOFF GARDENS - Unit 8G [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Walls Unit - Peeling/Needs Paint (Walls) (3) Level 2 0.02

Windows Unit - Inoperable/Not Lockable (Windows) Level 1 0.04

0.05 1.34

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 15 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 16: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Deficiency SeverityPoints

DeductedPoints

Received

Building 163003 - 272 WYCKOFF GARDENS - Unit 11E [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Ceiling Unit - Mold/Mildew/Water Stains/Water Damage(Ceiling)

Level 1 0.02

Ceiling Unit - Peeling/Needs Paint (Ceiling) (2) Level 1 0.01

Walls Unit - Damaged (Walls) Level 1 0.03

Walls Unit - Mold/Mildew/Water Stains/Water Damage(Walls)

Level 1 0.02

Health And Safety Deficiencies

Infestation HS - Insects / roaches (Infestation) (NLT ) Level 3 0.51

0.59 0.80

Building 163003 - 272 WYCKOFF GARDENS - Unit 16K [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Walls Unit - Mold/Mildew/Water Stains/Water Damage(Walls)

Level 1 0.02

0.02 1.38

Building 196001 - WARREN STREET - Common Areas [Possible Points : 1.35]

Non-Health And Safety Deficiencies

Ceiling CA - Holes/Missing Tiles/Panels/Cracks (Ceiling) Level 2 0.25

Ceiling CA - Peeling/Needs Paint (Ceiling) Level 1 0.02

Floors CA - Peeling/Needs Paint (Floors) Level 1 0.04

Floors CA - Peeling/Needs Paint (Floors) Level 2 0.04

Floors CA - Peeling/Needs Paint (Floors) Level 2 0.04

Walls CA - Peeling/Needs Paint (Walls) Level 1 0.02

Walls CA - Peeling/Needs Paint (Walls) Level 1 0.02

Walls CA - Peeling/Needs Paint (Walls) Level 2 0.04

0.49 0.87

Building 196001 - WARREN STREET - Unit 3C* [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Bathroom Items Unit - Lavatory Sink - Damaged/Missing (Bathroom) Level 1 0.13

Bathroom Items Unit - Shower/Tub - Damaged/Missing (Bathroom) Level 1 0.17

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 16 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 17: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Deficiency SeverityPoints

DeductedPoints

Received

Health And Safety Deficiencies

Emergency/FireExits

HS - Emergency/Fire Exits Blocked/Unusable(Emergency/Fire Exits) (LT )

Level 3 1.14

* The point deductions for this sub-area exceed the number of possible points. The points received cannot be negative so it is set to zero. 1.44 0.00

Building 196001 - WARREN STREET - Unit 5M [Possible Points : 1.24]

Non-Health And Safety Deficiencies

Bathroom Items Unit - Lavatory Sink - Damaged/Missing (Bathroom) Level 1 0.13

Bathroom Items Unit - Shower/Tub - Damaged/Missing (Bathroom) Level 1 0.17

Doors Unit - Damaged Hardware/Locks (Doors) (2) Level 2 0.08

Health And Safety Deficiencies

Infestation HS - Insects / roaches (Infestation) (NLT ) Level 3 0.51

0.89 0.36

Building 196001 - WARREN STREET - Unit 2 O [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Kitchen Items Unit - Refrigerator - Missing/Damaged/Inoperable(Kitchen)

Level 1 0.13

Walls Unit - Peeling/Needs Paint (Walls) Level 1 0.01

Health And Safety Deficiencies

Emergency/FireExits

HS - Emergency/Fire Exits Blocked/Unusable(Emergency/Fire Exits) (LT )

Level 3 1.14

1.27 0.12

Building 196001 - WARREN STREET - Unit 4L [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Bathroom Items Unit - Lavatory Sink - Damaged/Missing (Bathroom) Level 1 0.13

0.13 1.27

Building 196001 - WARREN STREET - Unit 6J [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Bathroom Items Unit - Lavatory Sink - Damaged/Missing (Bathroom) Level 1 0.13

Bathroom Items Unit - Shower/Tub - Damaged/Missing (Bathroom) Level 1 0.17

Ceiling Unit - Mold/Mildew/Water Stains/Water Damage(Ceiling)

Level 1 0.02

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 17 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 18: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Deficiency SeverityPoints

DeductedPoints

Received

Walls Unit - Mold/Mildew/Water Stains/Water Damage(Walls) (2)

Level 1 0.02

0.34 1.06

Building 256001 - ATLANTIC TERMINAL - Building Exterior* [Possible Points : 4.92]

Non-Health And Safety Deficiencies

Roofs BE- Damaged/Torn Membrane/Missing Ballast(Roofs)

Level 3 4.53

Walls BE- Missing/Damaged Caulking/Mortar (Walls) Level 1 0.55

* The point deductions for this sub-area exceed the number of possible points. The points received cannot be negative so it is set to zero. 5.08 0.00

Building 256001 - ATLANTIC TERMINAL - Building Systems [Possible Points : 6.56]

Non-Health And Safety Deficiencies

HVAC BS- Boiler/Pump/Cooling System Leaks (HVAC) Level 1 0.76

0.76 5.80

Building 256001 - ATLANTIC TERMINAL - Common Areas [Possible Points : 2.70]

Non-Health And Safety Deficiencies

Ceiling CA - Holes/Missing Tiles/Panels/Cracks (Ceiling) Level 2 0.25

Ceiling CA - Mold/Mildew/Water Stains/Water Damage(Ceiling)

Level 1 0.11

Ceiling CA - Peeling/Needs Paint (Ceiling) Level 1 0.02

Ceiling CA - Peeling/Needs Paint (Ceiling) Level 1 0.04

Ceiling CA - Peeling/Needs Paint (Ceiling) Level 1 0.04

Ceiling CA - Peeling/Needs Paint (Ceiling) Level 2 0.04

Ceiling CA - Peeling/Needs Paint (Ceiling) Level 2 0.04

Ceiling CA - Peeling/Needs Paint (Ceiling) Level 2 0.08

Floors CA - Hard Floor Covering Missing/DamagedFlooring/Tiles (Floors)

Level 2 0.25

Floors CA - Mold/Mildew/Water Stains/Water Damage(Floors)

Level 2 0.11

Floors CA - Peeling/Needs Paint (Floors) Level 2 0.04

Restroom Items CA - Leaking Faucet/Pipes (Plumbing) Level 1 0.13

Walls CA - Damaged (Walls) Level 2 0.19

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 18 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 19: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Deficiency SeverityPoints

DeductedPoints

Received

Walls CA - Mold/Mildew/Water Stains/Water Damage(Walls)

Level 1 0.05

Walls CA - Peeling/Needs Paint (Walls) Level 1 0.02

Walls CA - Peeling/Needs Paint (Walls) Level 2 0.04

Walls CA - Peeling/Needs Paint (Walls) (2) Level 1 0.04

Walls CA - Peeling/Needs Paint (Walls) (2) Level 1 0.04

Windows CA - Cracked/Broken/Missing Panes (Windows) Level 1 0.19

Windows CA - Inoperable/Not Lockable (Windows) (2) Level 1 0.19

Health And Safety Deficiencies

Windows CA - Inoperable/Not Lockable (Windows) (NLT ) Level 3 0.76

2.69 0.01

Building 256001 - ATLANTIC TERMINAL - Unit 4H [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Ceiling Unit - Peeling/Needs Paint (Ceiling) Level 1 0.01

Kitchen Items Unit - Refrigerator - Missing/Damaged/Inoperable(Kitchen)

Level 1 0.13

Health And Safety Deficiencies

Infestation HS - Insects / roaches (Infestation) (NLT ) Level 3 0.51

0.65 0.75

Building 256001 - ATLANTIC TERMINAL - Unit 11K [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Ceiling Unit - Peeling/Needs Paint (Ceiling) Level 2 0.02

0.02 1.38

Building 256001 - ATLANTIC TERMINAL - Unit 15E [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Doors Unit - Damaged Surface (Holes/Paint/Rust/Glass)(Doors)

Level 3 0.15

Kitchen Items Unit - Refrigerator - Missing/Damaged/Inoperable(Kitchen)

Level 1 0.13

0.28 1.11

Building 256001 - ATLANTIC TERMINAL - Unit 19A [Possible Points : 1.40]

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 19 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 20: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Deficiency SeverityPoints

DeductedPoints

Received

Non-Health And Safety Deficiencies

Doors Unit - Damaged Hardware/Locks (Doors) Level 2 0.08

Kitchen Items Unit - Refrigerator - Missing/Damaged/Inoperable(Kitchen)

Level 1 0.13

Walls Unit - Mold/Mildew/Water Stains/Water Damage(Walls)

Level 1 0.02

0.22 1.17

Building 256001 - ATLANTIC TERMINAL - Unit 19C [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Bathroom Items Unit - Shower/Tub - Damaged/Missing (Bathroom) Level 1 0.17

0.17 1.22

Building 256001 - ATLANTIC TERMINAL - Unit 22H [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Ceiling Unit - Peeling/Needs Paint (Ceiling) Level 1 0.01

Kitchen Items Unit - Refrigerator - Missing/Damaged/Inoperable(Kitchen)

Level 1 0.13

0.14 1.26

Building 256001 - ATLANTIC TERMINAL - Unit 26D [Possible Points : 1.40]

Non-Health And Safety Deficiencies

Doors Unit - Damaged Hardware/Locks (Doors) Level 2 0.08

Kitchen Items Unit - Range/Stove- Missing/Damaged/Inoperable(Kitchen)

Level 3 0.51

0.59 0.81

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 20 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 21: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Deficiency Details

Item Location/Comments Deficiency/Severity Decisions

Site - WYCKOFF GARDENS - Site(0)

Non-Health And Safety Deficiencies

Parking Lots/Driveways/Roads

272 WYCKOFFGARDENSBLACKTOP CRACKSON PARKING LOTPAVEMENT

Site - Cracks/Settlement/Heaving/Loose Materials/Potholes (Parking Lots/Driveways/Roads) - L2

- Damaged paving- Cracks greater than or equal

to 3/4"- This condition DOES NOT

RESULT in a Health andSafety concern.

Parking Lots/Driveways/Roads

185 WYCKOFFGARDENSPARKING LOT CRACKSIN FRONT OF 185 BLDG

Site - Cracks/Settlement/Heaving/Loose Materials/Potholes (Parking Lots/Driveways/Roads) - L2

- Damaged paving- Cracks greater than or equal

to 3/4"- This condition DOES NOT

RESULT in a Health andSafety concern.

Walkways and Steps ATLANTIC TERMINALSPALLING ONWALKWAY FRONT SIDENEAR CITY SIDEWALK

Site - Spalling (Walkways/Steps) - L1

- Spalling (includes concreteporches and entry stoops)

- Small areas of spalling (lessthan or equal to 4" by 4")

Walkways and Steps ATLANTIC TERMINALSPALLING ONWALKWAY NEAR MAINENTRY DOOR

Site - Spalling (Walkways/Steps) - L1

- Spalling (includes concreteporches and entry stoops)

- Small areas of spalling (lessthan or equal to 4" by 4")

Health And Safety Deficiencies

Hazards REAR AREA NEARPLAY GROUNDBROKEN GLASS ONGROUNDS

HS - Sharp Edges(Hazards) (NLT) - L3

- Sharp Edges - This COULDcause cutting/breaking ofskin or other bodily harm.

Building 163001 - WYCKOFF GARGENS[Sample,Inspected] - Building Exterior

None

Building 163001 - WYCKOFF GARGENS[Sample,Inspected] - Building Systems

None

Building 163001 - WYCKOFF GARGENS[Sample,Inspected] - Common Areas

Non-Health And Safety Deficiencies

Basement/Garage/ Basement CA - Peeling/Needs Paint - Peeling Paint or Needs

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 21 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 22: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

Carport MAIN BASEMENT AREACEILING PEELINGPAINT

(Ceiling) - L2 Paint- Peeling paint on more than

4 ceilings in common areas

Basement/Garage/Carport

BasementMAIN BASEMENTWALLS PEELING PAINT

CA - Peeling/Needs Paint(Walls) - L2

- Peeling Paint or NeedsPaint

- Greater than 4 square feetof wall area

Halls/Corridors/Stairs Floor 18PEELING PAINT INFRONT OF UNIT 18B

CA - Peeling/Needs Paint(Ceiling) - L1

- Peeling Paint or NeedsPaint

- Peeling paint on 1 to 4ceilings in common areas

Halls/Corridors/Stairs Floor 14STAIRWELL FL 14PEELING PAINT

CA - Peeling/Needs Paint(Floors) - L1

- Peeling Paint or NeedsPaint

- Greater than 1 to 4 squarefeet

Other CommunitySpaces

BasementLARGE CARPENTERROOM BASEMENTCEILING PEELING

CA - Peeling/Needs Paint(Ceiling) - L2

- Peeling Paint or NeedsPaint

- Peeling paint on more than4 ceilings in common areas

Other CommunitySpaces

BasementGROUND SHOP FLOORRUSTY WATER STAINS

CA - Mold/Mildew/WaterStains/Water Damage(Floors) - L2

- Mold or Mildew (forexample, a darkened area)or Water Stains or WaterDamage (for exampleevidence of waterinfiltration)

- 4 square inches to 1 squarefoot and you may or may notsee water

Other CommunitySpaces

Floor 1BRICK LAYERS SHOPWALL HOLE NEARENTRY DOOR

CA - Damaged (Walls) - L1 - Hole(s)- Between one square inch,

but smaller than a sheet ofpaper

Restrooms BasementCARPENTER SHOPBATHRM FL PEELINGPAINT

CA - Peeling/Needs Paint(Floors) - L1

- Peeling Paint or NeedsPaint

- Greater than 1 to 4 squarefeet

Storage BasementCARPENTER SHOPCLOSET DOOR WONTSELF LATCH

CA - Damaged Hardware/Locks (Doors) - L1

- All Other Doors (includescloset or other interiordoors)

- Hardware is damaged or

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 22 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 23: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

missing- Closet door does not

function as it should orcannot be locked.

Storage Floor 14SLOP CLOSET DOORWILL NOT SELF LATCH

CA - Damaged Hardware/Locks (Doors) - L1

- All Other Doors (includescloset or other interiordoors)

- Hardware is damaged ormissing

- Closet door does notfunction as it should orcannot be locked.

Storage BasementCARPENTERS CLOSETWALL PEELING PAINT

CA - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of two ormore wall areas

Storage Floor 2SLOP SINK CLOSETWALL PEELING PAINT

CA - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of two ormore wall areas

Storage Floor 1SLOP SINK CLOSETFLOOR PEELING PAINT

CA - Peeling/Needs Paint(Floors) - L1

- Peeling Paint or NeedsPaint

- Greater than 1 to 4 squarefeet

Storage Floor 21SLOP SINK CLOSETCEILING PEELINGPAINT

CA - Peeling/Needs Paint(Ceiling) - L1

- Peeling Paint or NeedsPaint

- Peeling paint on 1 to 4ceilings in common areas

Building 163001 - WYCKOFF GARGENS[Sample,Inspected] - Unit 13J

None

Building 163001 - WYCKOFF GARGENS[Sample,Inspected] - Unit 19D

Non-Health And Safety Deficiencies

Ceiling BathroomLOTS OF MOLDBATHRM CEILING

Unit - Mold/Mildew/WaterStains/Water Damage(Ceiling) - L3

- Mold or Mildew (forexample, a darkened area)or Water Stains or WaterDamage (for exampleevidence of waterinfiltration)

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 23 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 24: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

- Greater than 1 square foot(ceiling surface may havefailed)

- This condition MAYRESULT in a Health ANDSafety concern

Walls BathroomLOTS OF MOLDBATHRM WALLS

Unit - Mold/Mildew/WaterStains/Water Damage(Walls) - L3

- Mold or Mildew (forexample, a darkened area)or Water Stains or WaterDamage (for exampleevidence of waterinfiltration)

- Greater than 1 square foot(wall surface may havefailed)

- This condition MAYRESULT in a Health ANDSafety concern

Walls KitchenKITCHEN WALL NEARWIDOW SMALLAMOUNT MOLD

Unit - Mold/Mildew/WaterStains/Water Damage(Walls) - L1

- Mold or Mildew (forexample, a darkened area)or Water Stains or WaterDamage (for exampleevidence of waterinfiltration)

- 4 square inches to 1 squarefoot and you may or may notsee water

Windows BedroomBEDRM 2CONDENSATIONBETWEEN PANE LEFTWINDOW

Unit- Missing/DeterioratedCaulking/Seals/GlazingCompound (Windows) - L3

- Caulking, Seals, or GlazingCompound (includesthermopane or insulatedwindows)

- Deteriorated or missing- Window is damaged and not

weather-resistant OR thereis damage to thesurrounding structure ORthere is condensation ordiscoloration between theglass panes of aThermopane

Health And Safety Deficiencies

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 24 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 25: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

Air Quality LOTS OF MOLDBATHRM CEILING

HS - Mold and/or MildewObserved (Air Quality)(NLT) - L3

- Evidence of water infiltrationor other moisture producingcondition that causes mold,or mildew

- Greater than or equal to 1square foot of mold ormildew

Air Quality LOTS OF MOLDBATHRM WALLS

HS - Mold and/or MildewObserved (Air Quality)(NLT) - L3

- Evidence of water infiltrationor other moisture producingcondition that causes mold,or mildew

- Greater than or equal to 1square foot of mold ormildew

Building 163001 - WYCKOFF GARGENS[Sample,Inspected] - Unit 1J

Non-Health And Safety Deficiencies

Bathroom Items BathroomBATHRM TOILET SEATMISSING

Unit - Water Closet/Toilet-Damaged/Clogged/Missing(Bathroom) - L2

- Toilet (Unit)- Seat, hinge, cover, or flush

handle is missing ordamaged

Walls BedroomBEDRM 4 WALLPEELING PAINT

Unit - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of wallarea

Walls HallwaySMALL AMOUNT MOLDON WALL OVERBEDRM 2 DOOR

Unit - Mold/Mildew/WaterStains/Water Damage(Walls) - L1

- Mold or Mildew (forexample, a darkened area)or Water Stains or WaterDamage (for exampleevidence of waterinfiltration)

- 4 square inches to 1 squarefoot and you may or may notsee water

Windows BedroomCONDENSATIONBETWEEN PANEBEDRM 4, LEFTWINDOW

Unit- Missing/DeterioratedCaulking/Seals/GlazingCompound (Windows) - L3

- Caulking, Seals, or GlazingCompound (includesthermopane or insulatedwindows)

- Deteriorated or missing- Window is damaged and not

weather-resistant OR there

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 25 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 26: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

is damage to thesurrounding structure ORthere is condensation ordiscoloration between theglass panes of aThermopane

Health And Safety Deficiencies

Emergency/Fire Exits BedroomBEDRM 1 WINDOWBLOCKED BYFURNITURE ANDOTHER WINDOWBLOCKEED BYPADLOCK

HS - Emergency/Fire ExitsBlocked/Unusable(Emergency/Fire Exits) (LT)- L3

- Emergency/Fire Exits(applies only on third orlower floors)

- Blocked- Furniture

Emergency/Fire Exits BedroomBEDRM 2 DOORVISIBLE PADLOCKHARDWARE BLOCKEDEGRESS

HS - Emergency/Fire ExitsBlocked/Unusable(Emergency/Fire Exits) (LT)- L3

- Emergency/Fire Exits(applies only on third orlower floors)

- Blocked- Other Condition (Please

explain other condition inthe box below)

Emergency/Fire Exits BedroomBLOCKED EGRESSBEDRMS 2 AND 3SLIDE LATCH ONOUTSIDE OF DOOR

HS - Emergency/Fire ExitsBlocked/Unusable(Emergency/Fire Exits) (LT)- L3

- Emergency/Fire Exits(applies only on third orlower floors)

- Blocked- Other Condition (Please

explain other condition inthe box below)

Infestation KitchenDEAD ROACHES BASECABINET

HS - Insects /roaches(Infestation) (NLT) - L3

- Evidence of roaches- Multiple dead roaches

observed

Building 163001 - WYCKOFF GARGENS[Sample,Inspected] - Unit 5K

Non-Health And Safety Deficiencies

Ceiling BathroomPEELING PAINT OVERSHOWER IN CORNER

Unit - Peeling/Needs Paint(Ceiling) - L1

- Peeling Paint or NeedsPaint

- Greater than 1 and less than4 square feet

Doors BedroomBEDRM 1 HOLE ON

Unit - Damaged Surface(Holes/Paint/Rust/Glass)

- All Other Doors (includescloset or other interior

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 26 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 27: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

DOOR FROM MISSINGHARDWARE

(Doors) - L3 doors)- Surface is damaged- Door has holes.- Greater than 1 inch- This condition DOES NOT

RESULT in a Health andSafety concern.

Kitchen Items KitchenTOP AND LOWERGASKET TORN

Unit - Refrigerator - Missing/Damaged/Inoperable(Kitchen) - L1

- Refrigerator- Door seals are deteriorated

Walls HallwayPEELING PAINT NEARCORNER HALLWAY

Unit - Peeling/Needs Paint(Walls) - L2

- Peeling Paint or NeedsPaint

- Greater than 4 square feetof wall area

Health And Safety Deficiencies

Windows Living AreaWINDOW NEXT TO ACUNIT WILL NOT LOCK

Unit - Inoperable/NotLockable (Windows) (NLT)- L3

- Lock/Operability- Lock is missing or damaged

(only if the window wasdesigned to lock)

- Window is NOT accessiblefrom outside

Building 163001 - WYCKOFF GARGENS[Sample,Inspected] - Unit 9J

Non-Health And Safety Deficiencies

Doors BedroomBEDRM 2 DOORDAMAGED

Unit - Damaged Surface(Holes/Paint/Rust/Glass)(Doors) - L3

- All Other Doors (includescloset or other interiordoors)

- Surface is damaged- Door has holes.- Greater than 1 inch- This condition DOES NOT

RESULT in a Health andSafety concern.

Kitchen Items KitchenTORN LOWER GASKET

Unit - Refrigerator - Missing/Damaged/Inoperable(Kitchen) - L1

- Refrigerator- Door seals are deteriorated

Building 163002 - 185 WYCKOFF GARDENS[Sample,Inspected] - Building Exterior

Non-Health And Safety Deficiencies

Walls CHIPPED BRICK NEAR BE- Missing Pieces/Holes/ - Hole(s)

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 27 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 28: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

BASEMENT ENTRYDOOR TOP OF WALL

Spalling (Walls) - L2 - Greater than 1/2" indiameter, but smaller than asheet of paper

Health And Safety Deficiencies

Emergency/Fire Exits ALL OFFICE 1ST FLWINDOWSPADLOCKED ON THEOUTSIDE FORSECURITY

HS - Emergency/Fire ExitsBlocked/Unusable(Emergency/Fire Exits) (LT)- L3

- Emergency/Fire Exits(applies only on third orlower floors)

- Blocked- Other Condition (Please

explain other condition inthe box below)

Building 163002 - 185 WYCKOFF GARDENS[Sample,Inspected] - Building Systems

None

Building 163002 - 185 WYCKOFF GARDENS[Sample,Inspected] - Common Areas

Non-Health And Safety Deficiencies

Halls/Corridors/Stairs Floor 17HOLES IN STAIRWELLFIRE DOOR 17ASTAIRWELL, FROMMISSING HARDWARE

CA - Damaged Surface(Holes/Paint/Rust/Glass)(Doors) - L3

- Restroom Door or Fire/Emergency Door

- Surface is damaged- Fire/Emergency Door has

holes.- Greater than 1 inch- This condition DOES NOT

RESULT in a Health andSafety concern.

Halls/Corridors/Stairs Floor 77A STAIRWELL FIREDOOR WILL NOT SELFLATCH

CA - Damaged Hardware/Locks (Doors) - L3

- Restroom Door or Fire/Emergency Door

- Hardware is damaged ormissing

- Door does not function as itshould (it does not properlylatch).

Halls/Corridors/Stairs Floor 1STAIRWELL FLOORPEELING PAINT

CA - Peeling/Needs Paint(Floors) - L2

- Peeling Paint or NeedsPaint

- Greater than 4 square feet

Halls/Corridors/Stairs Floor 21HALL WINDOWCRACKED NO SHARPNEAR 21 E

CA - Cracked/Broken/Missing Panes (Windows) -L1

- Pane/Glass- Glass cracked

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 28 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 29: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

Halls/Corridors/Stairs Floor 6SLOP SINK CLOSETDOOR NOT SELFLATCHING

CA - Damaged Hardware/Locks (Doors) - L1

- All Other Doors (includescloset or other interiordoors)

- Hardware is damaged ormissing

- Closet door does notfunction as it should orcannot be locked.

Halls/Corridors/Stairs Floor 14STAIRWELL FLOORPEELING PAINT

CA - Peeling/Needs Paint(Floors) - L1

- Peeling Paint or NeedsPaint

- Greater than 1 to 4 squarefeet

Halls/Corridors/Stairs Floor 11HALLWAY NEARELEVATOR

CA - Graffiti - L1 - Graffiti on 1 interior buildingsurface

Office Floor 1ASSISTANTMANAGERS OFFICEDOOR WILL NOTLATCH AS DESIGNED.

CA - Damaged Hardware/Locks (Doors) - L2

- All Other Doors (includescloset or other interiordoors)

- Hardware is damaged ormissing

- Other interior door does notfunction as it should orcannot be locked.

Storage Floor 6SLOP CLOSET WALLSPEELING PAINT

CA - Peeling/Needs Paint(Walls) - L2

- Peeling Paint or NeedsPaint

- Greater than 4 square feetof wall area

Storage Floor 5INOPERABLE LIGHTSLOP CLOSET

CA - Missing/Damaged/Inoperable Fixture(Lighting) - L2

- Permanent lighting fixturesare missing or do notfunction

- 20 to 50% missing ordamaged so they do notfunction

Storage Floor 1SLOP SINK CLOSETDOOR WONT SELFLATCH

CA - Damaged Hardware/Locks (Doors) - L1

- All Other Doors (includescloset or other interiordoors)

- Hardware is damaged ormissing

- Closet door does notfunction as it should orcannot be locked.

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 29 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 30: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

Storage Floor 17PEELING PAINT WALLSLOP CLOSET

CA - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of two ormore wall areas

Storage Floor 12SLOP SINK CLOSETPEELING WALL PAINT

CA - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of two ormore wall areas

Storage Floor 10SLOP SINK CLOSETWALL PEELING PAINT

CA - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of two ormore wall areas

Storage Floor 3SLOP SINK CLOSETPEELING PAINT

CA - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of two ormore wall areas

Storage Floor 2SLOP SINK CLOSETWALL PEELING PAINT

CA - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of two ormore wall areas

Storage Floor 1TA STORAGE RMCEILING PEELINGPAINT

CA - Peeling/Needs Paint(Ceiling) - L1

- Peeling Paint or NeedsPaint

- Peeling paint on 1 to 4ceilings in common areas

Trash Collection Areas Floor 20TRASH CHUTE NOTSELF LATCHING

CA - Damaged/MissingComponents (Chutes) - L2

- Chute door does notself-close

- This condition DOES NOTRESULT in a Health andSafety concern.

Building 163002 - 185 WYCKOFF GARDENS[Sample,Inspected] - Unit 11A

Non-Health And Safety Deficiencies

Ceiling BathroomDAMAGED BATHRMCEILING

Unit - Holes/Missing Tiles/Panels/Cracks (Ceiling) -L2

- Hole(s)- Larger than a sheet of paper

(you cannot see through thehole)

Ceiling BathroomMOLD ON BATHRMCEILING

Unit - Mold/Mildew/WaterStains/Water Damage(Ceiling) - L1

- Mold or Mildew (forexample, a darkened area)or Water Stains or Water

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 30 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 31: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

Damage (for exampleevidence of waterinfiltration)

- 4 square inches to 1 squarefoot and you may or may notsee water

Building 163002 - 185 WYCKOFF GARDENS[Sample,Inspected] - Unit 19D

Non-Health And Safety Deficiencies

Walls BathroomDAMAGED TUBCAULKING

Unit - Damaged/Deteriorated Trim (Walls -L1

- Trim is Damaged orDecayed

- 5 to 10% of wall area

Windows Living AreaMIDDLE WINDOWCONDENSATIONBETWEEN PANE

Unit- Missing/DeterioratedCaulking/Seals/GlazingCompound (Windows) - L3

- Caulking, Seals, or GlazingCompound (includesthermopane or insulatedwindows)

- Deteriorated or missing- Window is damaged and not

weather-resistant OR thereis damage to thesurrounding structure ORthere is condensation ordiscoloration between theglass panes of aThermopane

Building 163002 - 185 WYCKOFF GARDENS[Sample,Inspected] - Unit 1J

Non-Health And Safety Deficiencies

Bathroom Items BathroomSINK STOPPERMISSING

Unit - Lavatory Sink -Damaged/Missing(Bathroom) - L1

- Bathroom Sink- A stopper is missing (only if

there is no stopper in thevisible area)

Bathroom Items BathroomTUB STOPPERMISSING

Unit - Shower/Tub -Damaged/Missing(Bathroom) - L1

- Shower or Tub (Unit)- A stopper is missing (only if

there is no stopper in thevisible area)

Building 163002 - 185 WYCKOFF GARDENS[Sample,Inspected] - Unit 5K

Non-Health And Safety Deficiencies

Kitchen Items Kitchen Unit - Range/Stove- Missing - Range/Stove/Oven

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 31 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 32: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

MORE THAN TWOBURNERSINOPERABLE

/Damaged/Inoperable(Kitchen) - L3

- Gas Range/Stove/Oven- Burner(s) not functioning- TWO OR MORE burners

are not functioning.- This condition DOES NOT

RESULT in a Health andSafety concern.

Kitchen Items KitchenTORN LOWER GASKET

Unit - Refrigerator - Missing/Damaged/Inoperable(Kitchen) - L1

- Refrigerator- Door seals are deteriorated

Building 163002 - 185 WYCKOFF GARDENS[Sample,Inspected] - Unit 9J

Non-Health And Safety Deficiencies

Doors HallwayMISSING CLOSETDOOR KNOB

Unit - Damaged Hardware/Locks (Doors) - L1

- All Other Doors (includescloset or other interiordoors)

- Hardware is damaged ormissing

- Closet door does notfunction as it should orcannot be locked.

Walls HallwayPEELING CRACKEDPAINT NEAR BATHRM

Unit - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of wallarea

Windows Living AreaFOGGY WINDOWCONDENSATIONBETWEEN PANE

Unit- Missing/DeterioratedCaulking/Seals/GlazingCompound (Windows) - L3

- Caulking, Seals, or GlazingCompound (includesthermopane or insulatedwindows)

- Deteriorated or missing- Window is damaged and not

weather-resistant OR thereis damage to thesurrounding structure ORthere is condensation ordiscoloration between theglass panes of aThermopane

Building 163003 - 272 WYCKOFF GARDENS[Sample,Inspected] - Building Exterior

Non-Health And Safety Deficiencies

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 32 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 33: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

Doors GRAVITY TANK DOORLARGE HOLES

BE - Damaged Surface(Holes/Paint/Rust/Glass)(Doors) - L3

- Entry Door (leads to theoutside of the building)

- Surface is damaged- Entry Door has holes.- This condition DOES NOT

RESULT in a Health andSafety concern.

Walls PEELING PAINTCOMMUNITY CENTER

BE- Stained/Peeling/NeedsPaint (Walls) - L1

- Stains or Peeling Paint orNeeds Paint

- Less than 50% of a singlewall is affected

Building 163003 - 272 WYCKOFF GARDENS[Sample,Inspected] - Building Systems

None

Building 163003 - 272 WYCKOFF GARDENS[Sample,Inspected] - Common Areas

Non-Health And Safety Deficiencies

Community Room Floor 1COMMUNITY CENTERSTAFF ONLY CLOSETCEILING PEELINGPAINT

CA - Peeling/Needs Paint(Ceiling) - L1

- Peeling Paint or NeedsPaint

- Peeling paint on 1 to 4ceilings in common areas

Community Room Floor 1COMMUNITY CENTERSTAFF BATHRM WALLHOLE BEHIND DOOR

CA - Damaged (Walls) - L1 - Hole(s)- Between one square inch,

but smaller than a sheet ofpaper

Halls/Corridors/Stairs Floor 1212TH FL STAIRWELLPEELING PAINT

CA - Peeling/Needs Paint(Floors) - L2

- Peeling Paint or NeedsPaint

- Greater than 4 square feet

Halls/Corridors/Stairs Floor 21PEELING PAINT ONFLOOR NEAR ROOFENTRY

CA - Peeling/Needs Paint(Floors) - L1

- Peeling Paint or NeedsPaint

- Greater than 1 to 4 squarefeet

Other CommunitySpaces

Floor 1TA CENTER BATHRMWINDOW SCREENTORN

CA - Damaged/MissingScreens (Windows) - L1

- A second means of windowegress exists

- Window bars are actuallychild safety bars

Storage Floor 21WALL DAMAGEDSPALLING SLOP SINK

CA - Damaged (Walls) - L2 - Hole(s)- Larger than a sheet of

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 33 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 34: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

WALL paper, but you cannot seethrough the hole

- ONE wall is affected.

Storage Floor 12SLOP SINK CLOSETPEELING PAINT

CA - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of two ormore wall areas

Storage Floor 11SLOP SINK CLOSETPEELING PAINT

CA - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of two ormore wall areas

Storage Floor 8SLOP SINK CLOSETPEELING PAINT

CA - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of two ormore wall areas

Storage Floor 4SLOP SINK CLOSETPEELING PAINT

CA - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of two ormore wall areas

Storage Floor 2SLOP SINK CLOSETPEELING PAINT

CA - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of two ormore wall areas

Storage Floor 21SLOP SINK CLOSETPEELING PAINT

CA - Peeling/Needs Paint(Ceiling) - L1

- Peeling Paint or NeedsPaint

- Peeling paint on 1 to 4ceilings in common areas

Storage Floor 6SLOP SINK CLOSETDOOR WONT SELFLATCH

CA - Damaged Hardware/Locks (Doors) - L1

- All Other Doors (includescloset or other interiordoors)

- Hardware is damaged ormissing

- Closet door does notfunction as it should orcannot be locked.

Health And Safety Deficiencies

Emergency/Fire Exits Floor 1TA CENTER OFFICE 1BOTH WINDOWS

HS - Emergency/Fire ExitsBlocked/Unusable(Emergency/Fire Exits) (LT)

- Emergency/Fire Exits(applies only on third orlower floors)

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 34 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 35: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

COVERED BYSECURITY GATEWHICH DOES NOTOPEN. BLOCKEDEGRESS

- L3 - Blocked- Other Condition (Please

explain other condition inthe box below)

Halls/Corridors/Stairs Floor 1GYMNASIUM DOUBLEDOORS WHICH OPENINTO HALLWAY HITEACH OTHER WHENCLOSING, DO NOTSELF LATCH ASDESIGNED

CA - Damaged Frames/Threshold/Lintels/Trim(Doors) (NLT) - L3

- Restroom Door or Fire/Emergency Door

- Frame is damaged causingthe door not to function orlock (this includesthresholds, lintels, trim,headers, and jambs)

- This condition DOES NOTRESULT in a Health andSafety concern.

Hazards Floor 1COMMUNITY CENTERMANAGER OFFICEWINDOW HASSECURITY WINDOWGUARD WHICH I WASABLE TO OPENWITHOUT TOOL ORKEY BUT DOES TAKETIME

HS - Other (Hazards) (NLT)- L3

- Any other - This DOES posea risk of bodily injury.

Building 163003 - 272 WYCKOFF GARDENS[Sample,Inspected] - Unit 11E

Non-Health And Safety Deficiencies

Ceiling BedroomBEDRM 1 INSIDECLOSET CEILINGPEELING PAINT

Unit - Peeling/Needs Paint(Ceiling) - L1

- Peeling Paint or NeedsPaint

- Greater than 1 and less than4 square feet

Ceiling BathroomMOLD ON BATHRMCEILING

Unit - Mold/Mildew/WaterStains/Water Damage(Ceiling) - L1

- Mold or Mildew (forexample, a darkened area)or Water Stains or WaterDamage (for exampleevidence of waterinfiltration)

- 4 square inches to 1 squarefoot and you may or may notsee water

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 35 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 36: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

Ceiling BathroomBATH CEILINGPEELING PAINT OVERTOILET

Unit - Peeling/Needs Paint(Ceiling) - L1

- Peeling Paint or NeedsPaint

- Greater than 1 and less than4 square feet

Walls BedroomBEDR 1 WALL HOLEINSIDE CLOSET

Unit - Damaged (Walls) -L1

- Hole(s)- Between one square inch

and up to a sheet of paper,but, you cannot see throughthe hole

Walls BedroomBEDRM 1 INSIDECLOSET PEELINGPAINT

Unit - Mold/Mildew/WaterStains/Water Damage(Walls) - L1

- Mold or Mildew (forexample, a darkened area)or Water Stains or WaterDamage (for exampleevidence of waterinfiltration)

- 4 square inches to 1 squarefoot and you may or may notsee water

Health And Safety Deficiencies

Infestation KitchenDEAD ROACHESUNDER BASE CABINET

HS - Insects /roaches(Infestation) (NLT) - L3

- Evidence of roaches- Multiple dead roaches

observed

Building 163003 - 272 WYCKOFF GARDENS[Sample,Inspected] - Unit 16K

Non-Health And Safety Deficiencies

Walls BathroomMOLD ON TUBCAULKING

Unit - Mold/Mildew/WaterStains/Water Damage(Walls) - L1

- Mold or Mildew (forexample, a darkened area)or Water Stains or WaterDamage (for exampleevidence of waterinfiltration)

- 4 square inches to 1 squarefoot and you may or may notsee water

Building 163003 - 272 WYCKOFF GARDENS[Sample,Inspected] - Unit 4E

Non-Health And Safety Deficiencies

Kitchen Items KitchenTORN LOWER GASKET

Unit - Refrigerator - Missing/Damaged/Inoperable(Kitchen) - L1

- Refrigerator- Door seals are deteriorated

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 36 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 37: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

Walls HallwayPEELING WALL PAINTNEAR KITCHEN

Unit - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of wallarea

Building 163003 - 272 WYCKOFF GARDENS[Sample,Inspected] - Unit 8G

Non-Health And Safety Deficiencies

Walls HallwayHALLWAY MISSINGPAINT OVER WALLREPAIR

Unit - Peeling/Needs Paint(Walls) - L2

- Peeling Paint or NeedsPaint

- Greater than 4 square feetof wall area

Walls BedroomBEDRM 3 MISSINGPAINT OVER WALLREPAIR

Unit - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of wallarea

Walls BedroombEDRM 1 PEELINGPAINT

Unit - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of wallarea

Windows Living AreaLEFT WINDOWDAMAGED BALLASTHARDWARE

Unit - Inoperable/NotLockable (Windows) - L1

- Lock/Operability- Window cannot be opened

or will not stay open (If thewindow is designed to doso.)

- Window is on 4th floor orabove

- There IS another operablewindow in the same floorarea.

Building 196001 - WARREN STREET[Sample,Inspected] - Building Exterior

None

Building 196001 - WARREN STREET[Sample,Inspected] - Building Systems

None

Building 196001 - WARREN STREET[Sample,Inspected] - Common Areas

Non-Health And Safety Deficiencies

Basement/Garage/Carport

BasementBASEMENT FLOOR

CA - Peeling/Needs Paint(Floors) - L2

- Peeling Paint or NeedsPaint

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 37 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 38: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

PEELING PAINT - Greater than 4 square feet

Basement/Garage/Carport

BasementPEELING PAINT

CA - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of two ormore wall areas

Closet/Utility/Mechanical

BasementBOILER RM DAMAGED/MISSING CEILINGTILES

CA - Holes/Missing Tiles/Panels/Cracks (Ceiling) -L2

- Panels/Tiles- More than 3 panels/tiles are

missing or damaged

Closet/Utility/Mechanical

BasementPEELING PAINT 574BASEMENT ENTRY

CA - Peeling/Needs Paint(Floors) - L2

- Peeling Paint or NeedsPaint

- Greater than 4 square feet

Closet/Utility/Mechanical

Basement574 BOILER RM WALLSPEELING

CA - Peeling/Needs Paint(Walls) - L2

- Peeling Paint or NeedsPaint

- Greater than 4 square feetof wall area

Halls/Corridors/Stairs Floor 3STAIRWELL B PEELINGFLOOR PAINT

CA - Peeling/Needs Paint(Floors) - L1

- Peeling Paint or NeedsPaint

- Greater than 1 to 4 squarefeet

Restrooms BasementPEELING PAINT MENSRM NEAR TOILET

CA - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of two ormore wall areas

Storage BasementGLAZIER SHOPCEILING PEELINGPAINT 574 BASEMENT

CA - Peeling/Needs Paint(Ceiling) - L1

- Peeling Paint or NeedsPaint

- Peeling paint on 1 to 4ceilings in common areas

Building 196001 - WARREN STREET[Sample,Inspected] - Unit 2 O

Non-Health And Safety Deficiencies

Kitchen Items KitchenTORN LOWER GASKET

Unit - Refrigerator - Missing/Damaged/Inoperable(Kitchen) - L1

- Refrigerator- Door seals are deteriorated

Walls BathroomPEELING WALL PAINT

Unit - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of wallarea

Health And Safety Deficiencies

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 38 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 39: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

Emergency/Fire Exits BedroomAC UNIT ANDFURNITURE BLOCKSBOTH WINDOWS 2NDFL UNIT BEDRM

HS - Emergency/Fire ExitsBlocked/Unusable(Emergency/Fire Exits) (LT)- L3

- Emergency/Fire Exits(applies only on third orlower floors)

- Blocked- Furniture

Building 196001 - WARREN STREET[Sample,Inspected] - Unit 3C

Non-Health And Safety Deficiencies

Bathroom Items BathroomMISSING SINKSTOPPER

Unit - Lavatory Sink -Damaged/Missing(Bathroom) - L1

- Bathroom Sink- A stopper is missing (only if

there is no stopper in thevisible area)

Bathroom Items BathroomTUB STOPPERMISSING

Unit - Shower/Tub -Damaged/Missing(Bathroom) - L1

- Shower or Tub (Unit)- A stopper is missing (only if

there is no stopper in thevisible area)

Health And Safety Deficiencies

Emergency/Fire Exits Bedroom3RD FL BEFRM 2 ONLYWINDOW BLOCKEDEGRESS

HS - Emergency/Fire ExitsBlocked/Unusable(Emergency/Fire Exits) (LT)- L3

- Emergency/Fire Exits(applies only on third orlower floors)

- Blocked- Air Conditioner

Building 196001 - WARREN STREET[Sample,Inspected] - Unit 4L

Non-Health And Safety Deficiencies

Bathroom Items BathroomMISSING SINKSTOPPER

Unit - Lavatory Sink -Damaged/Missing(Bathroom) - L1

- Bathroom Sink- A stopper is missing (only if

there is no stopper in thevisible area)

Building 196001 - WARREN STREET[Sample,Inspected] - Unit 5M

Non-Health And Safety Deficiencies

Bathroom Items BathroomMISSING SINKSTOPPER

Unit - Lavatory Sink -Damaged/Missing(Bathroom) - L1

- Bathroom Sink- A stopper is missing (only if

there is no stopper in thevisible area)

Bathroom Items BathroomMISSING TUBSTOPPER

Unit - Shower/Tub -Damaged/Missing(Bathroom) - L1

- Shower or Tub (Unit)- A stopper is missing (only if

there is no stopper in thevisible area)

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 39 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 40: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

Doors BedroomBEDRM 1 WONT LATCHLOOSE HARDWARE

Unit - Damaged Hardware/Locks (Doors) - L2

- All Other Doors (includescloset or other interiordoors)

- Hardware is damaged ormissing

- Other interior door does notfunction as it should orcannot be locked.

Doors HallwayHALL CLOSET DOOROFF TRACK

Unit - Damaged Hardware/Locks (Doors) - L1

- All Other Doors (includescloset or other interiordoors)

- Hardware is damaged ormissing

- Closet door does notfunction as it should orcannot be locked.

Health And Safety Deficiencies

Infestation KitchenDEAD ROACHES INPANS SINK BASECABINET

HS - Insects /roaches(Infestation) (NLT) - L3

- Evidence of roaches- Multiple dead roaches

observed

Building 196001 - WARREN STREET[Sample,Inspected] - Unit 6J

Non-Health And Safety Deficiencies

Bathroom Items BathroomMISSING TUBSTOPPER

Unit - Shower/Tub -Damaged/Missing(Bathroom) - L1

- Shower or Tub (Unit)- A stopper is missing (only if

there is no stopper in thevisible area)

Bathroom Items BathroomMISSING SINKSTOPPER

Unit - Lavatory Sink -Damaged/Missing(Bathroom) - L1

- Bathroom Sink- A stopper is missing (only if

there is no stopper in thevisible area)

Ceiling Living AreaDAMAGED CEILINGINSIDE CLOSET

Unit - Mold/Mildew/WaterStains/Water Damage(Ceiling) - L1

- Mold or Mildew (forexample, a darkened area)or Water Stains or WaterDamage (for exampleevidence of waterinfiltration)

- 4 square inches to 1 squarefoot and you may or may notsee water

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 40 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 41: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

Walls Living AreaWATER DAMAGEDWALL NEAR WINDOW

Unit - Mold/Mildew/WaterStains/Water Damage(Walls) - L1

- Mold or Mildew (forexample, a darkened area)or Water Stains or WaterDamage (for exampleevidence of waterinfiltration)

- 4 square inches to 1 squarefoot and you may or may notsee water

Walls Living AreaWATER DAMAGEDWALL INSIDE CLOSET

Unit - Mold/Mildew/WaterStains/Water Damage(Walls) - L1

- Mold or Mildew (forexample, a darkened area)or Water Stains or WaterDamage (for exampleevidence of waterinfiltration)

- 4 square inches to 1 squarefoot and you may or may notsee water

Building 256001 - ATLANTIC TERMINAL[Sample,Inspected] - Building Exterior

Non-Health And Safety Deficiencies

Roofs ROOF MEMBRANEDAMAGED

BE- Damaged/TornMembrane/Missing Ballast(Roofs) - L3

- Damaged or torn Membraneor Ballast

- The membrane or flashing isdamaged, and may allowwater penetration

Walls ROOF STACK WALLMISSING CAULKBETWEEN BRICK OVERROOF ENTRY DOOR

BE- Missing/DamagedCaulking/Mortar (Walls) -L1

- Missing Mortar- Missing mortar around one

brick

Building 256001 - ATLANTIC TERMINAL[Sample,Inspected] - Building Systems

Non-Health And Safety Deficiencies

HVAC BasementBOILER RM STEAMWATER PIPE LEAKING

BS- Boiler/Pump/CoolingSystem Leaks (HVAC) - L1

- Coolant, water, or steamleaking (not condensation orsweating)

- The coolant, water, or steamis NOT properly escapingfrom some apparatus (forexample, a pressure reliefvalve or water containment

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 41 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 42: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

and curb).- The system should NOT be

shut down.

Building 256001 - ATLANTIC TERMINAL[Sample,Inspected] - Common Areas

Non-Health And Safety Deficiencies

Basement/Garage/Carport

BasementBASEMENT FLOORSPEELING PAINT

CA - Peeling/Needs Paint(Floors) - L2

- Peeling Paint or NeedsPaint

- Greater than 4 square feet

Closet/Utility/Mechanical

BasementWATER PONDING ONBOILER RM FLOOR

CA - Mold/Mildew/WaterStains/Water Damage(Floors) - L2

- Mold or Mildew (forexample, a darkened area)or Water Stains or WaterDamage (for exampleevidence of waterinfiltration)

- 4 square inches to 1 squarefoot and you may or may notsee water

Closet/Utility/Mechanical

BasementBOILER RM WALLSPEELING PAINT

CA - Peeling/Needs Paint(Walls) - L2

- Peeling Paint or NeedsPaint

- Greater than 4 square feetof wall area

Closet/Utility/Mechanical

BasementBOILER RM CEILINGPEELING PAINT

CA - Peeling/Needs Paint(Ceiling) - L2

- Peeling Paint or NeedsPaint

- Peeling paint on more than4 ceilings in common areas

Day Care Floor 1MULTI PURPOSE RMPEELING

CA - Peeling/Needs Paint(Ceiling) - L1

- Peeling Paint or NeedsPaint

- Peeling paint on 1 to 4ceilings in common areas

Day Care Floor 1COMPUTER RMMISSING PAINT OVERWALL REPAIR

CA - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of two ormore wall areas

Day Care Floor 1PEELING MULTIPURPOSE RM

CA - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of two ormore wall areas

Halls/Corridors/Stairs Basement CA - Peeling/Needs Paint - Peeling Paint or Needs

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 42 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 43: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

STAIRWELL LEADINGTO BASEMENT CEILINGPEELING PAINT

(Ceiling) - L1 Paint- Peeling paint on 1 to 4

ceilings in common areas

Halls/Corridors/Stairs Floor 8WATER DAMAGEDCEILING OVERWINDOW

CA - Mold/Mildew/WaterStains/Water Damage(Ceiling) - L1

- Mold or Mildew (forexample, a darkened area)or Water Stains or WaterDamage (for exampleevidence of waterinfiltration)

- More than 1 square foot butless than 4 square feet andyou may or may not seewater

Halls/Corridors/Stairs Floor 1818TH FLOOR WINDOWDAMAGED HARDWARENEAR 18A

CA - Inoperable/NotLockable (Windows) - L1

- Lock/Operability- Window will not open or

close (only if the windowwas designed to open andclose)

- Window CANNOT besecured (by a lock or stick)

- Window is on 4th floor orabove

- There IS another operablewindow in the same floorarea.

Halls/Corridors/Stairs Floor 44TH FL WINDOW WILLNOT CLOSE ASDESIGNED OTHERWINDOWS ON FL

CA - Inoperable/NotLockable (Windows) - L1

- Lock/Operability- Window will not open or

close (only if the windowwas designed to open andclose)

- Window CANNOT besecured (by a lock or stick)

- Window is on 4th floor orabove

- There IS another operablewindow in the same floorarea.

Halls/Corridors/Stairs Floor 2A SIDE CRACKEDWINDOW PANE NOSHARP

CA - Cracked/Broken/Missing Panes (Windows) -L1

- Pane/Glass- Glass cracked

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 43 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 44: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

Halls/Corridors/Stairs Floor 14PEELING WALL PAINTNEAR WINDOW NEXTTO UNIT 14A

CA - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of two ormore wall areas

Halls/Corridors/Stairs Floor 8PEELING PAINT NEARWINDOW OF 8A

CA - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of two ormore wall areas

Kitchen BasementPEELING PAINT

CA - Peeling/Needs Paint(Ceiling) - L2

- Peeling Paint or NeedsPaint

- Peeling paint on more than4 ceilings in common areas

Other CommunitySpaces

BasementFEMALE LOCKER RMWALL DAMAGE

CA - Damaged (Walls) - L2 - Hole(s)- Larger than a sheet of

paper, but you cannot seethrough the hole

- ONE wall is affected.

Other CommunitySpaces

BasementFEMALE LOCKER RMFL DAMAGED FLOORTILES

CA - Hard Floor CoveringMissing/Damaged Flooring/Tiles (Floors) - L2

- Hard Floor Covering Missing/Damaged (all flooringmaterials except carpet)

- 10% to 50% of any singlefloor

Other CommunitySpaces

BasementMAINTENANCE SHOPWALL PEELING PAINT

CA - Peeling/Needs Paint(Walls) - L1

- Peeling Paint or NeedsPaint

- 1 to 4 square feet of two ormore wall areas

Other CommunitySpaces

BasementMAINTENANCE SHOPCEILING PEELINGPAINT

CA - Peeling/Needs Paint(Ceiling) - L1

- Peeling Paint or NeedsPaint

- Peeling paint on 1 to 4ceilings in common areas

Restrooms BasementMENS BATHRMCEILING PEELINGPAINT

CA - Peeling/Needs Paint(Ceiling) - L2

- Peeling Paint or NeedsPaint

- Peeling paint on more than4 ceilings in common areas

Restrooms BasementMENS BATHRM WATERSTAINED WALL NEEDSPAINT

CA - Mold/Mildew/WaterStains/Water Damage(Walls) - L1

- Mold or Mildew (forexample, a darkened area)or Water Stains or WaterDamage (for exampleevidence of water

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 44 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 45: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

infiltration)- 4 square inches to 1 square

foot and you may or may notsee water

Restrooms Floor 1TA STORAGE RMTOILET LEAK INSIDEBASIN

CA - Leaking Faucet/Pipes(Plumbing) - L1

- Toilet- The pipe leaks

Storage BasementBASEMENT STORAGERM CEILING PLASTERPEELING

CA - Holes/Missing Tiles/Panels/Cracks (Ceiling) -L2

- Hole(s)- Larger than a sheet of paper

(you cannot see through thehole)

Health And Safety Deficiencies

Day Care Floor 1CLASSRM 2 WINDOWLOCK MISSING

CA - Inoperable/NotLockable (Windows) (NLT)- L3

- Lock/Operability- Lock is missing or damaged

(only if the window wasdesigned to lock)

- Window is NOT accessiblefrom outside

Building 256001 - ATLANTIC TERMINAL[Sample,Inspected] - Unit 11K

Non-Health And Safety Deficiencies

Ceiling Living AreaPEELING CEILINGPAINT

Unit - Peeling/Needs Paint(Ceiling) - L2

- Peeling Paint or NeedsPaint

- Greater than 4 square feet

Building 256001 - ATLANTIC TERMINAL[Sample,Inspected] - Unit 15E

Non-Health And Safety Deficiencies

Doors Living AreaHOLE IN ENTRY DOORFROM MISSINGHARDWARE

Unit - Damaged Surface(Holes/Paint/Rust/Glass)(Doors) - L3

- Entry Door to Unit- Surface is damaged- Entry Door has holes.- This condition DOES NOT

RESULT in a Health andSafety concern.

Kitchen Items KitchenTORN LOWER GASKET

Unit - Refrigerator - Missing/Damaged/Inoperable(Kitchen) - L1

- Refrigerator- Door seals are deteriorated

Building 256001 - ATLANTIC TERMINAL[Sample,Inspected] - Unit 19A

Non-Health And Safety Deficiencies

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 45 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 46: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

Doors BedroomDAMAGED HARDWAREBEDRM DOOR WONTLATCH

Unit - Damaged Hardware/Locks (Doors) - L2

- All Other Doors (includescloset or other interiordoors)

- Hardware is damaged ormissing

- Other interior door does notfunction as it should orcannot be locked.

Kitchen Items KitchenTORN LOWER GASKET

Unit - Refrigerator - Missing/Damaged/Inoperable(Kitchen) - L1

- Refrigerator- Door seals are deteriorated

Walls BathroomSMALL AMOUNT MOLDON TUB CAULKING

Unit - Mold/Mildew/WaterStains/Water Damage(Walls) - L1

- Mold or Mildew (forexample, a darkened area)or Water Stains or WaterDamage (for exampleevidence of waterinfiltration)

- 4 square inches to 1 squarefoot and you may or may notsee water

Building 256001 - ATLANTIC TERMINAL[Sample,Inspected] - Unit 19C

Non-Health And Safety Deficiencies

Bathroom Items BathroomMISSING TUBSTOPPER

Unit - Shower/Tub -Damaged/Missing(Bathroom) - L1

- Shower or Tub (Unit)- A stopper is missing (only if

there is no stopper in thevisible area)

Building 256001 - ATLANTIC TERMINAL[Sample,Inspected] - Unit 22H

Non-Health And Safety Deficiencies

Ceiling BathroomBATHRM CEILINGPEELING PAINT

Unit - Peeling/Needs Paint(Ceiling) - L1

- Peeling Paint or NeedsPaint

- Greater than 1 and less than4 square feet

Kitchen Items KitchenTORN LOWER GASKET

Unit - Refrigerator - Missing/Damaged/Inoperable(Kitchen) - L1

- Refrigerator- Door seals are deteriorated

Building 256001 - ATLANTIC TERMINAL[Sample,Inspected] - Unit 26D

Non-Health And Safety Deficiencies

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 46 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 47: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Item Location/Comments Deficiency/Severity Decisions

Doors BedroomBEDRM DOOR MISSINGSTRIKER PLATE WONTLATCH

Unit - Damaged Hardware/Locks (Doors) - L2

- All Other Doors (includescloset or other interiordoors)

- Hardware is damaged ormissing

- Other interior door does notfunction as it should orcannot be locked.

Kitchen Items KitchenMORE THAN TWOBURNERSINOPERABLE

Unit - Range/Stove- Missing/Damaged/Inoperable(Kitchen) - L3

- Range/Stove/Oven- Gas Range/Stove/Oven- Burner(s) not functioning- TWO OR MORE burners

are not functioning.- This condition DOES NOT

RESULT in a Health andSafety concern.

Building 256001 - ATLANTIC TERMINAL[Sample,Inspected] - Unit 4H

Non-Health And Safety Deficiencies

Ceiling BedroomBEDRM 2 CEILINGPEELING PAINT

Unit - Peeling/Needs Paint(Ceiling) - L1

- Peeling Paint or NeedsPaint

- Greater than 1 and less than4 square feet

Kitchen Items KitchenTORN LOWER GASKET

Unit - Refrigerator - Missing/Damaged/Inoperable(Kitchen) - L1

- Refrigerator- Door seals are deteriorated

Health And Safety Deficiencies

Infestation HallwayLIVE ROACHCRAWLING UP WALL

HS - Insects /roaches(Infestation) (NLT) - L3

- Evidence of roaches- Single live roach observed

Inspection Summary Report (POA) for Inspection #625073

Report generation date/time:10/23/2018 01:55 AM Score Version: 1 Page: 47 of 47Report template version: 04/15/2011 Note: The report generation date/time does not reflect the inspection release date/time.

Page 48: Inspection Summary Report (POA) for Inspection #625073 Documents/Brooklyn - PACT RF… · Fax: (718) 522-3288 Email: shelisa.reid@nycha.nyc.gov Type Building Units Expected Actual

Notice: Modifications to the Inspection Summary Report

With the rollout of the new Uniform Physical Condition Standards (UPCS) inspection software (version 4.0).PIH-REAC now has the capability to collect more detailed information about observations made during theinspection of properties. Therefore, the report has been modified to provide this detailed information, and also tomake the results of the inspection more clear. The following explains the major changes to the report.

Changes to Score Summary - The section of the report, which summarizes the score, has been modifiedto better explain how the final score was derived for the property, and the source of lost points. Additionally,score information from the two most recent inspections of the property is provided to allow comparison tothis inspection's score.

Addition of scored and non-scored deficiency reports - The section of the report that displays observeddeficiencies has been divided into two sections: the Score Report and the Deficiency Report. Non-scoreddeficiencies refer to multiple deficiencies of the same type observed with the same sub-area, they arereported for informational purposes only and are not scored. Only one deficiency of the same type for thesame sub-area is counted for scoring purposes.

Score Report - a detailed account of only the scored deficiencies by sub-area.

Deficiency Report - A detailed account of all deficiencies, both scored and non-scored, by sub-area.In addition, standardized locations and more descriptive information for each deficiency are provided.

To read more about the above, and for additional assistance in understanding the report, you may access theInspection Summary Report Guide (version 4.0) athttp://www.hud.gov/offices/reac/products/pass/inspectionrpt40.cfm