INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

2180348B Feb. 2002

. Biarritz II electric shower .

Installation and Operating Instructions

Page 2: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

CONTENTS Page

Important safety information 1

Introduction 2

Advice to users 2

Key to main components 3

Electrical requirements 4 - 5

Water requirements 6

Siting of the shower 6 - 7

Fitting the shower to the wall 8

Plumbing connections 8 - 9

Electrical connections 10

Replacing the cover 11

Fitting the riser rail 12

Fitting the hose and sprayhead 13

Commissioning 14

Operating the shower 15 - 16

Operating functions 16

Adjusting the sprayhead 17

Cleaning 18

Cleaning the filter 19

Spare parts 20 - 21

Fault finding 22 - 23

Temperature / flow rate graph 24

Guarantee, service policy, etc. rear cover

To ensure the product suitability for commercial and multiple installations,please contact Triton’s specification advisory service prior to installation.

Telephone: (024) 7632 5491

Facsimile: (024) 7632 4564

E mail: [email protected]

Page 3: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

1

PLEASE READ THIS IMPORTANT SAFETY INFORMATION� Products manufactured by Triton are safe and without risk provided they are installed, used and

maintained in good working order in accordance with our instructions and recommendations.� DO NOT operate shower if frozen, or suspected of being frozen. It must thaw out before using.� DO NOT operate the unit if the sprayhead or spray hose becomes damaged.� DO NOT restrict flow out of the shower by placing sprayhead in direct contact with your body.� DO NOT operate the shower if water ceases to flow during use or if water has entered inside the

unit because of an incorrectly fitted cover.� WARNING: If re-starting the shower immediately after stopping, be aware that a slug of hot

water will be expelled for the first few seconds.

1 GENERAL1.1 Isolate the electrical and water supplies beforeremoving the cover.1.2 Read all of these instructions and retain themfor later use.1.3 DO NOT take risks with plumbing or electricalequipment.1.4 Isolate electrical and water supplies BEFOREproceeding with the installation.1.5 The unit must be mounted onto the finishedwall surface (on top of the tiles). DO NOT tile up tounit after fixing to wall.1.6 Contact Customer Service (see back page), ifany of the following occur;a) If it is intended to operate the shower at pressuresabove the maximum or below the minimum stated.b) If the unit shows a distinct change in performance.c) If the shower is frozen.1.7 If it is intended to operate the shower in areasof hard water (above 200 ppm temporary hardness), ascale inhibitor may have to be fitted. For advice on theTriton Scale Inhibitor, contact Triton Customer Service.1.8 The sprayplate and cartridge must be cleanedregularly with descalent to remove scale and debris,otherwise restrictions to the flow on the outlet of theunit will result in higher temperatures and could alsocause the Pressure Relief Device in unit to operate.1.9 This product is not suitable for mounting intosteam rooms or steam cubicles.2 PLUMBING2.1 The plumbing installation must comply withWater Regulations, Building Regulations or anyparticular regulations as specified by Local WaterCompany or Water Undertakers and should be inaccordance with BS 6700.2.2 The supply pipe must be flushed to clear debrisbefore connecting to the shower unit.2.3 DO NOT solder pipes or fittings within 300mmof the shower appliance, as heat transfer can damagecomponents.

2.4 DO NOT fit any form of outlet flow control asthe outlet acts as a vent for the heater can.2.5 DO NOT use excessive force when makingconnections to the flexible hose or sprayhead, fingertightness is sufficient.2.6 All plumbing connections MUST be completedBEFORE making the electrical connections.3 ELECTRICAL3.1 The installation must comply withBS 7671 ‘Requirements for electrical installations’ (IEEwiring regulations) or any particular regulations asspecified by the local Electrical Supply Company.3.2 This appliance MUST be earthed.3.3 In accordance with ‘The Plugs and Sockets etc.(Safety) Regulations 1994’, this appliance is intendedto be permanently connected to the fixed wiring ofthe electrical mains system.3.4 Ensure all electrical connections are tight toprevent overheating.3.5 Fuses do not give personal protection againstelectric shock.3.6 To enhance electrical safety a 30mA residualcurrent device (RCD) should be installed in all UKelectric and pumped shower circuits. This may be partof the consumer unit or a separate unit.3.7 Switch off immediately at isolating switch ifwater ceases to flow during use.3.8 Other electrical equipment i.e. extractor fans,pumps must not be connected to the circuits withinthe unit.3.9 Switch off at isolating switch when not in use.This is a safety procedure recommended with allelectrical appliances.3.10 As with all electrical appliances it isrecommended to have the shower and installationchecked at least every two years by a competentelectrician to ensure there is no deterioration due toage and usage.

Page 4: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

2

ADVICE TO USERS

The following points will help you understandhow the shower operates:

A The electric heating elements operate at aconstant rate at your chosen power setting. It isthe flow rate of the water passing through theheater unit which determines the showertemperature at any given setting. (The slower theflow the hotter the water becomes, and the fasterthe flow the cooler the water).

B During Winter, mains water supply will becooler than in Summer. Therefore thetemperature of the shower will vary betweenseasons on any one setting of the temperaturecontrol, e.g. if you have chosen setting number 6as your preferred shower temperature in theSummer, you will have to increase that numberduring Winter by adjusting the temperaturecontrol clockwise (which in effect slows the waterflow).

C The stabiliser valve minimises variations inshower temperature during mains water pressurechanges. If changes in shower temperature areexperienced during normal use, it will most likelybe caused by the water pressure falling near to orbelow the minimum level. The drop in pressuremay be due to water being drawn off at otherpoints in the house whilst the shower is in use. Ifpressure drops appreciably below the minimum,the heating elements will automatically cut out.

If ever the water becomes too hot and youcannot obtain cooler water, first check thatthe sprayplate in the sprayhead has notbecome blocked.

DO NOT place items such as soap or shampoobottles on top of the unit. Liquid could seepthrough the joint between the cover andbackplate, and possibly damage the sealingrubber.

Replacement parts can be ordered from CustomerService. See ‘spare parts’ for details and partnumbers.

Due to continuous improvement and updating,specification may be altered without prior notice.

INTRODUCTION

This book contains all the necessary fitting andoperating instructions for your Triton Biarritz IIelectric shower. Please read them carefully.

The shower installation must be carried out by asuitably qualified person and in the sequence ofthis instruction book.

Care taken during the installation will ensure along, trouble-free life from your shower.

SPECIFICATIONS

ElectricalNominal power Nominal powerrating at 240V rating at 230V8.5kW – (40A MCB rating) 7.8kW – (40A MCB rating)9.5kW – (40A MCB rating) 8.7kW – (40A MCB rating)

WaterInlet connection – 15mm diameter.Outlet connection – 1/2” BSP male thread.

Entry PointsWater – top, bottom, back, left or right.Cable – top, bottom, back, left or right.

MaterialsBackplate, cover, controls, sprayhead – ABS.Sprayplate – Acetal.Elements – Minerally insulated corrosion resistantmetal sheathing.

DimensionsHeight - 300mmWidth - 208mmDepth - 110mm

Standards and ApprovalsSplashproof rating IPX4.

Complies with the requirements of current Britishand European safety standards for household andsimilar electrical appliances.

Complies with requirements of the BritishElectrotechnical Approvals Board (BEAB).

Meets with Compliance with EuropeanCommunity Directives (CE).

Page 5: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

3

1

2

2

3

3 3

4

5

6

7

8

9

1011

12

13

14

15

255mm

58 mm

208 mm

300mm

Fig.1KEY TO MAIN COMPONENTS

Inside unit (fig.1)

1 Top cable/pipe entry

2 Wall screw fixings

3 Cover screw fixings

4 Thermal safety cut-out (main)

5 Power selector assembly

6 Can and element assembly

7 Pressure switch assembly

8 Stabilising valve

9 Terminal block

10 Earth connection

11 Solenoid valve

12 Water inlet

13 Outlet temperature limiter

14 Pressure relief device (PRD)

15 Shower outlet

Pack contents

Shower unit

Sprayhead

Riser rail kit and fittings

Soap dish

Flexible hose

Screw fixing kit

Instructions, guarantee, etc.

Page 6: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

4

ELECTRICAL REQUIREMENTS

WARNINGTHIS APPLIANCE MUST BE EARTHED

The installation, supply cable and circuitprotection must conform with IEE wiringregulations and be sufficient for theamperage required.The following notes are for guidance only:

1 The shower must only be connected to a230-240V ac supply. If you are installing a showerwith a kilowatt rating above 9kW, it is advisableto contact the local electricity supply company.

1.1 The electrical rating of the shower is shownon the rating label (fig.2) within the unit.

Meter

Incomingsupplyfuse

Metertails

Consumerunit

Pull cordisolating switch

Showerunit

Fuse ormcb

RCD(can be part ofconsumer unit)

80A or 100Amain switch

Fig.3 schematic of installation circuit

2 Before making any sort of electricalconnection within the installation, ensure that noterminal is live. If in any doubt, switch off thewhole installation at the consumer unit.

3 The shower must be connected to its ownindependent electrical circuit. IT MUST NOT beconnected to a ring main, spur, socket outlet,lighting circuit or cooker circuit.

3.1 The electrical supply must be adequate forthe loading of the unit and existing circuits.

4 Check your consumer unit (main fuse box)has a main switch rating of 80A or above and thatit has a spare fuse way which will take the fuse ormcb necessary for the shower (fig.3).

4.1 If your consumer unit has a rating below80A or if there is no spare fuse way, then theinstallation will not be straight forward and mayrequire a new consumer unit serving the house orjust the shower.

4.2 You will need to contact the local electricitycompany. They will check the circuit and carry outwhat is necessary. They will also check the mainbonding.

5 The earth continuity conductor of theelectrical installation must be effectivelyconnected electrically to all exposed metal parts ofother appliances and services in the room inwhich the shower is to be installed, to conform tocurrent IEE regulations.

Table A

CIRCUIT PROTECTION

unit cartridgerating mcb fuse

7.0kW 30/32A 30A

7.5kW 32A 35A

8.0kW 40A 35A

8.5kW 40A 45A

9.0kW 40A 45A

9.5kW 40/45A 45A

10.5kW 45A 45A

Fig.2

Page 7: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

5

ELECTRICAL REQUIREMENTS

5.1 All exposed metallic parts in the bathroommust be bonded together using a cable of at least4mm2 cross sectional area. These parts includemetal baths, radiators, water pipes, taps andwaste fittings.

6 For close circuit protection DO NOT use arewireable fuse. Instead use a suitably ratedminiature circuit breaker (MCB) or cartridge fuse(see table A).

6.1 In the interest of electrical safety a 30mAresidual current device (RCD) should be installedin all UK electric and pumped shower circuits. Thismay be part of the consumer unit or a separateunit.

7 A 45 amp double pole isolating switch witha minimum contact gap of 3mm in both polesmust be incorporated in the circuit.

7 A 45 amp double pole isolating switch witha minimum contact gap of 3mm in both polesmust be incorporated in the circuit.

7.1 It must have a mechanical indicatorshowing when the switch is in the OFF position,and the wiring must be connected to the switchwithout the use of a plug or socket outlet.

7.2 The switch must be accessible and clearlyidentifiable, but out of reach of a person using afixed bath or shower, except for the cord of acord operated switch, and should be placed sothat it is not possible to touch the switch bodywhile standing in a bath or shower cubicle. Itshould be readily accessible to switch off afterusing the shower.

8 Where shower cubicles are located in anyrooms other than bathrooms, all socket outlets inthose rooms must be protected by a 30mA RCD.

9 The current carrying capacity of the cablemust be at least that of the shower circuitprotection (see table B).

9.1 To obtain full advantage of the powerprovided by the shower, use the shortest cableroute possible from the consumer unit to theshower.

9.2 It is also necessary to satisfy thedisconnection time and thermal constraints whichmean that for any given combination of currentdemand, voltage drop and cable size, there is amaximum permissible circuit length.

10 The shower circuit should be separated fromother circuits by at least twice the diameter of thecable or conduit.

10.1 The current rating will be reduced if thecabling is bunched with others, surrounded bythermal loft or wall insulation or placed in areaswhere the ambient temperature is above 30°C.Under these conditions, de-rating factors applyand it is necessary to select a larger cable size.

10.2 In the majority of installations, the cablewill unavoidably be placed in one or more ofthe above conditions. This being so, it isstrongly recommended to use a minimum of10mm cabling throughout the showerinstallation.

10.3 In any event, it is essential that individualsite conditions are assessed by a competentelectrician in order to determine correct cable sizeand permissible circuit length.

Twin and earth PVC insulated cable

CURRENT CARRYING CAPACITYclipped direct or

installed in an in conduit buried in a noninsulated wall or trunking insulated wall

6mm2 6mm2 6mm2

32A 38A 46A

10mm2 10mm2 10mm2

43A 52A 63A

16mm2 16mm2 16mm2

57A 69A 85A

Note: Cable selection is dependenton de-rating factors

Table B

Page 8: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

WATER REQUIREMENTS

The installation must be in accordance with WaterRegulations/Byelaws.

To ensure activation of the heating elements, theshower must be connected to a mains watersupply with a minimum running pressure of100 kPa (1.0 bar) at a minimum flow rate of eightlitres per minute (nine litres per minute for the9,5kW rated model) and a maximum staticpressure of 1,000 kPa (10 bar).

NOTE: If the stated flow rates are not available, itmay not be possible to achieve optimumperformance from the unit throughout the year.

During periods of high ambient temperatures itmay be necessary to select a low power setting toachieve your preferred shower temperature.

The water supply can be taken from a cold waterstorage cistern provided there is a minimum headof ten metres above the sprayhead. It must be anindependent supply to the shower only.

If it is intended to operate the shower at pressuresabove the maximum or below the minimumstated, contact Customer Service for advice.

Fig.4 shows a typical system layout.

Do not use jointing compounds on any pipefittings for the installation.

SITING OF THE SHOWER

WARNING: The shower must not bepositioned where it will be subjected tofreezing conditions.

FOR EASE OF SERVICING, THE UNIT MUSTALWAYS BE MOUNTED ON THE SURFACE OFTILED WALLS. NEVER TILE UP TO THE UNIT.

Refer to figure 5 for correct siting of shower.Position the unit where it will NOT be in directcontact with water from the sprayhead. Positionthe shower unit vertically.

Allow sufficient room between the ceiling and theshower to access the cover top screws.

NOTE: Water Regulations requires the sprayheadbe ‘constrained by a fixed or sliding attachment sothat it can only discharge water at a point not lessthan 25mm above the spill-over level of therelevant bath, shower tray or other fixedappliance’. The use of the supplied soap dish will

Isolatingstopvalve

Mainswatersupply

Showerunit

Mains electric supply (via double pole switch)

Doublepole

isolatingswitch

Separate permanentlyconnected supply

from consumer unit

Fig.4Diagrammatic view (not to scale)

6

Page 9: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

Outline of bathor shower tray

Mains cold watersupply (either top,

side, bottomor rear entry)

Shower unit canbe mounted either

side of riser rail

25mm minimum

Soapdish

Shower unitmust notbe withinan area1 metre

from base

Height of sprayhead

andshower to suituser's

requirement

Fig.5Diagrammatic view (not to scale)

in most cases meet this requirement, but if thesprayhead can be placed within a bath, basin orshower tray, then a double check valve, or similar,must be fitted in the supply pipework to preventback-flow.

Pressure relief safety deviceA pressure relief device (PRD) is designed into theshower unit which complies with Europeanstandards. The PRD provides a level of applianceprotection should an excessive build up ofpressure occur within the shower.DO NOT operate the shower with a damaged orkinked shower hose, or a blocked sprayheadwhich can cause the PRD to operate.

When commissioning, the sprayhead must beremoved from the flexible hose, while at the sametime the temperature control must be at theminimum flow position. Failure to follow thisprocedure may also cause the PRD to operate.

Ensure the shower is positioned over a bath orshower tray because if the PRD operates, thenwater will eject from the bottom of the unit.Should this happen, turn off the electricity andwater supplies to the shower at the isolatingswitch and stopvalve. Contact Customer Servicefor advice on replacing the PRD.

7

Page 10: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

8

FITTING THE SHOWER TO THE WALL

NOTE: The control knobs are an integral part ofthe cover – do not attempt to remove them.

Important: The unit must be mounted on a flatsurface which covers the full width and length ofthe backplate. It is important that the wall surfaceis flat otherwise difficulty may be encounteredwhen fitting the cover and subsequent operationof the unit may be impaired.

Unscrew the two top and one bottom retainingscrews (fig.6) and lift the cover from thebackplate.

Entry positions for the mains water and electriccable are from the top, bottom, either side orfrom the back. NOTE: Deviations from thedesignated entry points will invalidate productapprovals.

If a bottom entry has been chosen, fit theappropriate cut-out in the top of the backplate(fig.7).If a top entry has been chosen, fit the appropriatecut-out in the bottom of the cover (fig.8).If a side entry is required, the cover will have to becut out. Carefully remove the appropriate area byusing a knife or junior hacksaw (fig.9).

If installing a feed pipe from the back or bottom,the centre of the inlet valve to the wall surface is20mm (fig.10).

NOTE: If entry is from the back, the nut of thecompression fitting will be partially behind thesurface of the wall (fig.10). This area MUST beleft clear when plastering over the pipework inorder to make the nut accessible for futureadjustments.

After choosing the site for the shower, use thebackplate as a template and mark the two fixingholes (fig.11). Drill and plug to suit the fixingscrews supplied.

(The wallplugs provided are suitable for most brickwalls – use an appropriate masonry drill, but if thewall is plasterboard or a soft building block, youmust use special wallplugs and an appropriate drillobtainable from most hardware stores).

Screw the bottom fixing screw into positionleaving the base of the screw head protruding6mm (0.25in) out from the wall.

Fig.6

Fig.8

Fig.7

Page 11: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

Hook the backplate over the bottom screw and fitthe top fixing screw into position.Do not fully tighten the screws at this stage, asthe fixing holes are elongated to allow for out ofsquare adjustment after the plumbingconnections have been completed.

PLUMBING CONNECTIONSPlumbing to precede wiring.

WARNING: The outlet of the shower acts as avent and must not be connected to anythingother than the hose and sprayhead supplied.

DO NOT use jointing compounds on any pipefittings for the installation.DO NOT use soldered fittings within the vicinity ofthe shower unit.

Compression fittings MUST be used to connect tothe inlet of the shower.

NOTE: An additional stopvalve (complying withWater Regulations) MUST be fitted in the mainswater supply to the shower as an independentmeans of isolating the water in order to carry outmaintenance or servicing.

Important: Before completing the connection ofthe water supply to the inlet of the shower, and incompliance with Water Regulations, flush out thepipework to remove all swarf and system debris.This can be achieved by connecting a hose to thepipework and turning on the mains water supplylong enough to clear the debris to waste.

Procedure: Turn off the water supply either at themains stopvalve or the isolating stopvalve.Connect the mains water supply to the inlet ofthe shower via 15mm copper, stainless steel orplastic pipe using a 15mm x 15mm compressionfitting. NOTE: The inlet fitting is designed to entera compression fitting only. DO NOT use push fitconnectors as full engagement cannot beguaranteed. DO NOT use excessive force whenmaking these connections.

Ensure the backplate is square on the wall andtighten the two retaining screws which hold it tothe wall.

Turn on the mains water supply and check forleaks in the pipework connection to the shower.

NOTE: At this stage no water can flow throughthe unit.

20mm

Fig.10

Fig.9

Fig.11

9

Page 12: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

10

ELECTRICAL CONNECTIONS

SWITCH OFF THE ELECTRICITY SUPPLY.

Figure 12 shows a schematic wiring diagram.

The cable entry points are shown in figure 1.The cable can be surface clipped, hidden or via20mm conduit.

NOTE: Conduit entry can only be from rear. Routethe cable into the shower unit and connect to theterminal block (fig.13) as follows:-

Earth cable to terminal marked E

Neutral cable to terminal marked N

Live cable to terminal marked L

IMPORTANT: Fully tighten the terminal blockscrews and ensure that no cable insulation istrapped under the screws. Loose connectionscan result in cable overheating,

The supply cable earth conductor must besleeved. The outer sheath of the supply cablemust be stripped back to the minimum.

The supply cable must be secured either byrouting through conduit or in trunking or byembedding in the wall, in accordance with currentIEE regulations.

NOTE: The use of connections within the unit, orother points in the shower circuit, to supplypower to other equipment i.e. extractor fans,pumps etc. will invalidate the guarantee.

DO NOT switch on the electricity supply untilthe cover has been fitted.

T70si

1

2

3

4

57

L N

6

8

E

9

Terminalblock

Fig.13

Fig.12

1 Terminal block2 Thermal cut-out (main)3 Thermal cut-out (outlet)4 Microswitches5 Start/stop microswitch

6 Solenoid valve7 Element8 Element9 Neon

NOTE: The elements on UK models are to240V specification and will give a lower kWrating if the voltage supply is below 240V.

Page 13: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

11

REPLACING THE COVER

The power selector spindle must be aligned asshown (fig.14).

To ensure that the temperature control is correctlypositioned on the stabilising valve, temporarilyplace the cover in position so that the splinesengage and rotate the temperature control fullyanti-clockwise.

Remove the cover and position the temperaturecontrol knob so that it points towards the No.1position (fig.15).

Position the power selector to the 'STOP' position(fig.16).

Replace the cover squarely to the backplate andguide into position so that the knobs locatecorrectly into the splined spindles. Should anydifficulty arise, re-check the points above.

Secure the cover in position with the threeretaining screws.

Fig.14

Fig.15

Fig.16

Page 14: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

FITTING THE RISER RAIL

Decide the position for the rail on the wall withinthe shower area. Proceed as follows:

A Offer one of the two brackets to the wall forthe lower position only. Note there are three holesin the brackets but two screws will usually besufficient. However, the centre hole must be usedso mark this and either of the other two. Drill andplug the wall. (The wallplugs provided are suitablefor most brick walls – use an appropriate masonrydrill, but if the wall is plasterboard or a softbuilding block, you must use special wallplugs andan appropriate drill obtainable from mosthardware stores).

Replace the bracket to the wall and secure to thewall with the screws supplied (fig.17). Locate therail onto this lower bracket ensuring the railengages fully on the bracket. Ensure the indent inthe riser rail engages into the cut-out on thebracket end (fig.18).

B Locate the second bracket on top of the rail.Again mark the centre hole plus one of the othertwo holes. Ensure the rail is vertical. Remove thebracket and rail. Drill and plug the wall.

C With the saddle, spacer and lever parts to hand,screw the saddle two or three turns into the lever(fig.19). Place the saddle and lever into theslider/holder assembly (fig.20) so that the holesalign, then slide onto the rail (fig.21). Tighten tothe rail by turning the lever. When tight, the levershould be facing forwards and not pointing to thewall. If not, slacken off and remove from the rail.Rotate the saddle and lever 180° within theslider/holder assembly then replace onto the railand tighten.Ensure the tapered thin end of thespray head holder is in the uppermost position.

D Place the rail onto the installed lower bracket.Replace the upper bracket onto the rail andsecure the bracket to the wall with the screwssupplied (fig.22).

E Place a trim cover onto each bracket ensuring

WARNING: Check there are no hidden cablesor pipes before drilling holes for wall plugs.Use great care when using power tools nearwater. The use of a residual current device(RCD) is recommended.

Saddle

Lever

Slider/holderassemblySaddle

Lever

Spacer

Taperedthin end

Fig.17

Fig.18

Fig.19 Fig.20

Fig.21

Fig.23

Fig.24

Fig.22

12

Page 15: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

the large protrusion at the narrow end of the trimcover, engages into the slot between the rail andbracket (fig.23) before pushing and clicking theother end into place (fig.24).

F Snap the soap dish onto the rail (fig.25) belowthe holder assembly. Prise open the soap dishcollar and fit onto the rail (fig.26) below the dish.Note the collar is slightly tapered and should befitted ‘thinner section’ uppermost. Ensure itlocates firmly in the soap dish (fig.27) so that itholds the dish at the required height on the rail.

FITTING THE HOSE AND SPRAYHEAD

Feed the flexible hose through the appropriatesoap dish aperture (fig.28) in order that the dishacts as a retaining ring (Water Regulations).

Screw the flexible hose to the shower outlet andsprayhead (fig.29) ensuring the supplied washersare in place at both ends of the flexible hose.

Place the sprayhead into the holder (fig.30) andcheck that it fits correctly. NOTE: The holder isslightly tapered and the sprayhead and hose willonly fit from one direction. Important: It is theconical end of the hose which grips into theholder. The sprayhead will not fit in the holderwithout the hose attached. However at this stage,disconnect the sprayhead and lay aside until theshower unit has been commissioned.

TIGHTENING THE SPRAYHEAD HOLDER

In the unlikely event of the sprayhead droppingdown in use because the holder is loose, this canbe remedied by re-tightening the screw inside theholder unit. To gain access to this screw, one ofthe wall mounting brackets must be removed –the top one is preferable as the rail can be left inposition on the lower bracket.

First remove the sprayhead and hose from theholder. Insert a small screw driver into the slot onthe trim cover (fig.31), and carefully prise off thecover.

Unscrew the fixing screws holding the bracket andremove it from the wall and rail.

Holding the rail, unlock the lever and slide off thelever and holder assembly. Remove the lever andsaddle from the slider/holder assembly. The screwinside the slider/holder is now accessible.

With an appropriate screw driver, tighten thescrew (fig.32). Re-assemble in the reverse order.

Thin section at top

Collar

Fig.27 Fig.28

Sprayhead

Holder

Washers

Shower

Sprayhead

Fig.29 Fig.30

Fig.26Fig.25

Screw

Slider/holderassembly

Fig.31 Fig.32

13

Page 16: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

14

COMMISSIONING

The first operation of the shower is intended toflush out any remaining unit debris, and to ensurethe heater unit contains water before theelements are switched on. This operation must becarried out with the flexible hose screwed to theoutlet but without the sprayhead attached. Ensurethe outlet of the flexible hose is directed to waste.

Before turning on the electric and mains watersupplies to the shower, ensure that the powerselector is at the 'STOP' position (fig.33) and thetemperature control is rotated fully clockwise to‘10’, the minimum flow position (fig.34).NOTE: Failure to turn the control to ‘10’ maycause the PRD to operate.

Turn on the mains water supply to the shower atthe isolating stop valve and then switch on theelectric supply to the shower at the isolatingswitch. The power indicator will light.

Switch the power selector to the ‘COLD’ position(fig.35) and wait until water starts to flow fromthe flexible hose.

Slowly rotate the temperature control fully anti-clockwise to ‘1’, the maximum flow position(fig.36).

It will take approximately thirty seconds for asmooth flow of water to be obtained whilst airand any debris is being dispersed from theshower.

When a smooth flow of water is obtained, rotatethe temperature control from ‘1’ to ‘10’ severaltimes to release any trapped air within the unit.

Once flushing out has been completed, stop thewater flow by turning the power selector to the‘STOP’ position.

Fit the sprayhead to the flexible hose and place inthe sprayhead holder.

The shower is now ready for normal operation.

Fig.33

Fig.34

Fig.36

Fig.35

Page 17: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

Temperaturecontrol

Powerselector

Economy

ColdHigh

Stop

Fig.37OPERATING THE SHOWER

Ensure the commissioning procedure has beencarried out.

To start the showerTurning the power selector to the red or bluesymbol positions will commence water to flow.

To stop the showerSwitch the power selector to the ‘STOP’ positionand water will cease to flow.

WARNING: If re-starting immediately afterstopping, be aware that a slug of hot waterwill be expelled for the first few seconds.

To use the power selectorThe power selector has four positions (stop, cold,economy and high) as shown in fig.37.

STOP is to switch off the electric and water supplyat the shower – no flow or power used.

Blue symbol is cold water only. Adjustment of thetemperature control at this setting will only alterthe force of the water from the sprayhead. ITWILL NOT ALTER THE WATER TEMPERATURE.

Single red symbol is an economy setting for usingless power during warmer months. Temperatureadjustment at this setting is via the temperaturecontrol. Note: If the stated flow rate required forthe unit cannot be met due to low waterpressure, it will be necessary to operate the uniton this setting during the warmer monthsbecause of flow rate limitations entering the unit.

Double red symbol is a high setting which allowsthe highest flow achievable for your preferredtemperature. This setting should normally beregarded as optimum shower performancethroughout the year. Temperature adjustment atthis setting is via the temperature control.

To adjust the shower temperatureThe water temperature is altered by increasing ordecreasing the flow rate of the water through theshower via the temperature control (fig.37).

After obtaining your preferred showertemperature, the number can be rememberedand left as the normal setting and should onlyneed to be altered to compensate for seasonalchanges in ambient water temperature.NOTE: The preferred number on ‘economy’ willgive a different temperature to the same numberposition on ‘high’.

NOTE: IN NORMAL USE, IT IS IN ORDER TOLEAVE THE WATER SUPPLY PERMANENTLYON TO THE SHOWER UNIT, BUT AS WITHMOST ELECTRICAL APPLIANCES, THE UNITMUST BE SWITCHED OFF AT THEISOLATING SWITCH WHEN NOT IN USE.

15

Page 18: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

To decrease the shower temperatureTurn the temperature control anti-clockwise; thiswill increase the flow of water through theshower and be indicated by the lower numbers.

To increase the shower temperatureTurn the temperature control clockwise; this willdecrease the flow of water through the showerand be indicated by the higher numbers.

NOTE: It is advisable to be certain that theshowering temperature is satisfactory by testingwith your hand before stepping under thesprayhead. There will always be a time delay often to fifteen seconds between selecting a flowrate and the water reaching the stabletemperature for that flow rate.

WARNING: After any servicing of the mainswater supply, always ensure the unit is started onCOLD in order to purge any air in the pipework.

Caution: It is recommended that persons whomay have difficulty understanding or operatingthe shower controls should not be left unattendedwhilst showering. Special consideration should begiven to young children and the less able bodied.

OPERATING FUNCTIONS

Power on indicator (fig.38)When the electricity supply to the shower isswitched on at the isolating switch, the ‘power’indicator will light.

Low water pressure cut-outIf the water pressure falls below the minimumrequired for correct operation of the shower,power will be switched off to the heatingelements preventing any maintained temperaturerises (water will continue to flow).

Power will automatically be restored whenadequate water pressure returns.

Temperature limiterDuring normal operation if an overheattemperature is sensed, power to the elements willbe reduced. Water will continue to flow. Whenthe temperature has cooled sufficiently, power tothe elements will be automatically restored to theprevious setting at the time of interruption.

Safety cut-outThe unit is fitted with a thermal cut-out safety

Biarr i tz I I

16

Power onindicator

Fig.38

Page 19: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

17

device. In the event of abnormal operation whichcould cause unsafe temperatures within the unit,the device will disconnect the heating elements. Itwill require a visit from a qualified engineer todetermine the nature of the fault and replace thesafety cut-out device, once the unit has beenrepaired.

ADJUSTING THE SPRAYHEAD

Four sprayhead patterns are available (fig.39).Adjustment is by turning the bezel on thesprayhead in either direction until the desiredpattern is obtained.

MAXIA full spray perfect for a relaxing shower.

ULTRAA focused spray for a refreshing, satisfyingshower.

NEEDLEA tingling, fine spray for a highly invigoratingshower.

JETA concentrated spray for an exhilarating shower.

ULTRA

MAXI

NEEDLE

JET

Fig.39

Page 20: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

18

CLEANING

Do not use abrasive or solvent cleaningfluids. The shower unit, riser rail, hose,etc. should be cleaned using a soft clothand warm water.

It is advised before cleaning, to turn the isolationswitch off, thus avoiding the shower beingaccidentally switched on.

IT IS IMPORTANT TO KEEP THE SPRAYHEADCLEAN TO MAINTAIN THE PERFORMANCE OF THESHOWER. The hardness of the water willdetermine the frequency of cleaning. For example,if the shower is used every day in a very hardwater area, it may be necessary to clean thesprayhead on a weekly basis.

Sprayplate removal

There is no need to remove the sprayhead fromthe hose.

Using the removal tool supplied (fig.40), locatethe three raised ’bosses’ into the three recesses inthe sprayplate. Hold in firmly and twist anti-clockwise (fig.41). This movement may turn thecartridge assembly as well until it reaches a ‘stop’.

Hold the cartridge firmly and continue to twistanti-clockwise. Having loosened the sprayplatesufficiently, it can be unscrewed and removedcompletely (fig.42).

Clean the sprayplate with a suitable brush orpreferably leave it to soak overnight in a mildproprietary descalent. Ensure all traces of scale areremoved and thoroughly rinse in clean waterafterwards.

Before replacing the sprayplate, switch the powerback on at the isolating switch and direct the hoseand sprayhead to waste.

Turn the temperature control fully anti-clockwise.

Start the shower by turning the power selector tothe COLD position.

This operation will flush out any loose scaledeposits in the unit and sprayhead. Stop afterapproximately thirty seconds.

Refit the sprayplate by screwing clockwise. Usethe tool to screw the sprayplate tight.

WARNING

Do not use ‘powerful’ abrasive or solventcleaning fluids when cleaning the shower asthey may damage the plastic fittings

Sprayplatekey

Sprayplate

Fig.41

Fig.40

Fig.42

Page 21: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

19

Inletfilter

Fig.43

CLEANING THE FILTER

The inlet filter is situated inside the solenoid inlet(fig.43).

To gain access to the filter will require the coverto be removed and disconnection and removal ofthe compression fitting. Also, depending on theincoming pipework arrangements, if there is notenough slack in the pipework, it could mean theremoval of the unit from the wall.

When cleaning the filter, do not use a sharpobject, as it will cause damage. It is preferable touse an old toothbrush or similar.

Page 22: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

20

7

6

2

5

3

4

1Ref. Description Part No.

1 4 mode sprayhead (white) 22420050

2 Sprayhead holder 83306190

3 Brackets (pr.) 83306160

4 Riser rail 7042409

5 Flexible hose (chrome) 22007500

6 Soapdish 22008960

7 Cover assemblyc/w knobs 84800050

SPARE PARTS

Page 23: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

21

13

8 9

12

10

14

11

16

17

SPARE PARTS

8 Can assembly 8.5kW 84500460Can assembly 9.5kW 84500290

9 Terminal block 22009230

10 Switching module assemblyc/w actuator & m’switches 82500210

11 Solenoid valve assembly 22007740

12 Thermal cut-out (main) 22009860

13 Pressure Relief Device 82800450

14 Stabiliser valve assembly 82600550

15 Outlet pipe & wiring assy. 83306990

16 Insert trim - cover 7052245

17 Insert trim - backplate 7052244

– Power neon 82300980

– Terminal block live wire assy. 82301000

Ref. Description Part No.

15

Page 24: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

22

1 Showerinoperable, no waterflow.

2 Water too hot.

3 Watertemperature cyclinghot/cool at intervals.

4 Water too cool orcold.

1.1 Interrupted powersupply.

1.2 Unit malfunction.

2.1 Not enough waterflowing through theshower.

2.2 Blockage in supply.

2.3 Increase in ambientwater temperature.

3.1 Heater cycling onoutlet temperature limiter.

4.1 Too much flow.

4.2 Water pressure belowminimum required (seerating label).

4.3 Reduction in ambientwater temperature.

4.4 Electrical malfunctionor thermal cut-out hasoperated.

1.1.1 Blown fuse or circuit breaker. Check supply.Renew or reset fuse or circuit breaker. If it failsagain, consult a qualified electrician.1.1.2 Power cut. Check other appliances and ifnecessary, contact local Electricity Supply Co.

1.2.1 Have unit checked. Ring Customer Service.

2.1.1 Increase flow rate via temperature control. 2.1.2 Blocked sprayhead - clean or replaceblocked sprayplate in sprayhead.

2.2.1 Check if stop valves are fully open. Check ifblockage in inlet filter.

2.3.1 Re-adjust flow rate to give increased flow.2.3.2 Select ‘economy’ power.

3.1.1 See 'Water too hot' causes 2.1, 2.2 and 2.3and their appropriate action/cures. If it continues,contact Triton Customer Service.

4.1.1 Reduce flow rate via temperature control.

4.2.1 Is water supply mains or tank fed ?4.2.2 If tank fed, re-plumb to mains water supplyor see 4.2.4.4.2.3 If mains fed, ensure that mains stopvalve isfully open and that there are no other restrictionsin the supply while shower is in use, or see 4.2.4.4.2.4 Fit pump to give minimum pressure (seerating label). Contact Customer Service for advice.

4.3.1 Re-adjust flow rate to give reduced flow.4.3.2 Select ‘high’ power.

4.4.1 Have unit checked by suitably qualifiedelectrician or contact Triton Customer Service.

FAULT FINDINGIMPORTANT: Switch OFF the electricity at the mains supply and remove the circuit fuse beforeremoving the cover from the shower while attempting any fault finding inside the unit.

Problem/Symptom Cause Action/cure

Page 25: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Biarr i tz I I

23

5 Shower variesfrom normaltemperature to coldduring use.

6 Pressure reliefdevice has operated(water ejected fromPRD tube).

5.1 Water pressure hasdropped below minimumrequired.

6.1 Blocked sprayhead.

6.2 Twisted/blockedflexible shower hose.

6.3 Sprayhead notremoved whilstcommissioning.

5.1.1 Wait until the water pressure resumes tonormal.

6.1.1 Clean or replace blocked sprayplate insprayhead and then fit new PRD.

6.2.1 Check for free passage through hose.Replace the hose if necessary and fit new PRD.

6.3.1 Fit new PRD. Commission unit withsprayhead removed.

Note: Identify cause of operation before fitting new PRD unit.When fitting a new PRD, follow the commissioning procedure.

It is advised all electrical maintenance/repairs to the showershould be carried out by a suitably qualified person.

FAULT FINDING (continued)

Problem/Symptom Cause Action/cure

Page 26: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

UKASQUALITY

MANAGEMENT

003

B iarr i tz I I

24

0

20

40

60

0.6

10.6

1 1.4

1.8

2.2

2.6

3 3.4

3.8

4.2

4.6

5 5.4

5.8

6.2

6.6

7 7.4

7.8

8.2

8.6

9 9.4

9.8

10.2

9.5kW8.5kWEconomy

Temperature / flow rate graph (0° C ambient)

Page 27: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower
Page 28: Installation and Operating Instructions...electric shock. 3.6 To enhance electrical safety a 30mA residual current device (RCD) should be installed in all UK electric and pumped shower

Service PolicyIn the event of a complaint occurring, the followingprocedure should be followed:1 Telephone Customer Service on (024) 7637 2222(08457 626591 in Scotland and in Northern Ireland),having available the model number and power ratingof the product, together with the date of purchase.2 Triton Customer Service will be able to confirmwhether the fault can be rectified by either theprovision of a replacement part or a site visit from aqualified Triton service engineer.3 If a service call is required it will be booked and thedate of call confirmed. In order to expedite yourrequest, please have your postcode available whenbooking a service call.4 It is essential that you or an appointedrepresentative (who must be a person of 18 years ofage or more) is present during the service engineer'svisit and receipt of purchase is shown.5 A charge will be made in the event of an abortedservice call by you but not by us, or where a callunder the terms of guarantee has been booked andthe failure is not product related (i.e. scaling andfurring, incorrect water pressure, pressure reliefdevice operation, electrical installation faults). 6 If the product is no longer covered by theguarantee, a charge will be made for the site visit andfor any parts supplied.7 Service charges are based on the account beingsettled when work is complete, the engineer will thenrequest payment for the invoice. If this is not made tothe service engineer or settled within 10 workingdays, a £10 administration charge will be added.

Replacement Parts PolicyAvailability: It is the policy of Triton to maintainavailability of parts for the current range of productsfor supply after the guarantee has expired. Stocks ofspare parts will be maintained for the duration of theproduct’s manufacture and for a period of five yearsthereafter.In the event of a spare part not being available asubstitute part will be supplied.Payment: The following payment methods can beused to obtain spare parts:1 By post, pre-payment of pro forma invoice bycheque or money order.2 By telephone, quoting credit card (MasterCard orVisa) details.3 By website order, www.tritonshowers.co.uk

Triton Plc, Shepperton Park, Caldwell Road,Nuneaton, Warwickshire. CV11 4NR

Customer Service� (024) 7637 2222

Scottish and Northern IrelandCustomer Service� 08457 626591

Trade Installer Hotline� (024) 7632 5491

Fax: (024) 7632 4564www.tritonshowers.co.uk

E mail: [email protected]

Triton Plc guarantee this product against allmechanical and electrical defects arising from faultyworkmanship or materials for a period of two yearsfor domestic use only, from the date of purchase,provided that it has been installed by a competentperson in full accordance with the fittinginstructions.Any part found to be defective during this guaranteeperiod we undertake to repair or replace at ouroption without charge so long as it has beenproperly maintained and operated in accordancewith the operating instructions, and has not beensubject to misuse or damage.This product must not be taken apart, modified orrepaired except by a person authorised by Triton Plc.This guarantee applies only to products installedwithin the United Kingdom and does not apply toproducts used commercially.This guarantee does not affect your statutory rights.

What is not covered:1 Breakdown due to: a) use other than domesticuse by you or your resident family; b) wilful act or

neglect; c) any malfunction resulting from theincorrect use or quality of electricity, gas or water orincorrect setting of controls; d) faulty installation.2 Repair costs for damage caused by foreign objectsor substances.3 Total loss of the product due to non-availability ofparts.4 Compensation for loss of use of the product orconsequential loss of any kind.5 Call out charges where no fault has been foundwith the appliance.6 The cost of repair or replacement of pressurerelief devices, sprayheads, hoses, riser rails and/orwall brackets, isolating switches, electrical cable,fuses and/or circuit breakers or any other accessoriesinstalled at the same time.7 The cost of routine maintenance, adjustments,overhaul modifications or loss or damage arisingtherefrom, including the cost of repairing damage,breakdown, malfunction caused by corrosion,furring, pipe scaling, lime scale, system debris orfrost.

TR I T O N ST A N D A R D GU A R A N T E E