27
QJ SOLAR CIXI CITY RIXING ELECTRONICS CO.,LTD Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148 1 QJ INSTALLATION GUIDE FOR QJ SOLAR PHOTOVOLTAIC MODULE Contents Purpose of this guide General Safety precaution for installing a solar photovoltaic system Product Identification Mechanical Installation Selecting the location Selecting the proper support frame Ground mount Roof mount Pole mount General Installation Electrical Installation Grid-connected electrical system Grounding General installation Commission and Maintenance Blocking diodes and bypass diodes Testing, commissioning and troubleshooting Maintenance Testing and replacing bypass diodes Disclaimer of Liability

INSTALLATION GUIDE FOR QJ SOLAR PHOTOVOLTAIC · PDF fileINSTALLATION GUIDE FOR QJ SOLAR PHOTOVOLTAIC MODULE Contents Purpose of this guide General Safety precaution for installing

  • Upload
    ledien

  • View
    231

  • Download
    2

Embed Size (px)

Citation preview

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

1

QJ

INSTALLATION GUIDE FOR QJ SOLAR

PHOTOVOLTAIC MODULE

Contents

●Purpose of this guide

General

Safety precaution for installing a solar photovoltaic system

●Product Identification

●Mechanical Installation

Selecting the location

Selecting the proper support frame

Ground mount

Roof mount

Pole mount

General Installation

●Electrical Installation

Grid-connected electrical system

Grounding

General installation

●Commission and Maintenance

Blocking diodes and bypass diodes

Testing, commissioning and troubleshooting

Maintenance

Testing and replacing bypass diodes

●Disclaimer of Liability

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

2

QJ

Purpose of this guide

This guide contains information regarding the installation and safe handling of OVIERA

SOLAR photovoltaic module (hereafter is referred to as "module "). QJ SOLAR hereafter

is referred to as "QJ".

All instructions should be read and understood before attempting to install. If there are any

question, please contact our sales department for further explanation. The installer should

conform to all the safety precautions listed in this guide when installing the module. Local

codes should also be followed in such installations.

Before installing a solar photovoltaic system,the installer should become familiar with the

mechanical and electrical requirement for such a system. Keep this guide in a safe place for

future reference (care and maintenance) and in case of sale or disposal of the module at the

end of its useful life.

General

●Installing solar photovoltaic systems may require specialized skills and knowledge.

Installation should be performed only by qualified person.

●The installer should assume the risk or all injury that might occur during installation,

including without limitation, the risk of electric shock.

●One individual module may generate DC voltages greater than 30 volts when exposed to

direct sunlight. Contact with a DC voltage of 30V or more is potentially hazardous.

●When disconnecting wires connected to a photovoltaic module that is exposed to

sunlight, and electric arc may result. Such arcs may cause burns, may start fires and may

otherwise create problems. Therefore, be extremely careful!

●Photovoltaic solar modules change light energy to direct-current electrical energy. They

are designed for outdoor use. Modules may be ground mounted, mounted on rooftops,

vehicles or boats. Proper design of support structures is the responsibility of the system

designer and installer. Proper use of mounting holes is suggested in a following

paragraph.

●Do not attempt to disassemble the module, and do not remove any attached nameplates

or components.

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

3

QJ

●Do not apply paint or adhesive to module top surface.

●Artificially concentrated sunlight shall not be directed on the module or panel.

●When installing the system, abide with all local, regional and national statutory

regulations. Obtain a building permit where necessary. Abide with any local and national

regulations when mounting on vehicles or boats.

Safety precaution for installing a solar photovoltaic system

●Solar modules produce electrical energy when light shines on their front surface. The DC

voltage may exceed 30V. If modules are connected in series, the total voltage is equal to the

sum of the individual module voltages. If modules are connected in parallel, the total

current is equal to the sum of individual module currents.

●Keep children well away from the system while transporting and installing mechanical

and electrical components.

●Completely cover the module with an opaque material during installation to keep

electricity from being generated.

●Do not wear metallic rings, watchbands, ear, nose, lip rings or other metallic devices

while installing or troubleshooting photovoltaic systems.

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

4

QJ

●Use only insulated tools that are approved for working on electrical installations.

●Abide with the safety regulations for all other components used in the system, including

wiring and cables, connectors, charging regulators, inverters, storage batteries and

rechargeable batteries, etc.

●Use only equipment, connectors, wiring and support frames suitable for use in a solar

electric systems. Always use the same type of module within a particular photovoltaic

system.

●The electrical characteristics are within ±3% of the indicated values of Pmax under

standard test conditions (irradiance of 100mW/cm2, AM 1.5 spectrums, and a cell

temperature of 25℃{77ºF})

●Under normal conditions, a photovoltaic module is likely to experience conditions that

produce more current and/or voltage than reported at standard test conditions. Accordingly,

the values of ISC and VOC marked on this module should be multiplied by a factor of 1,25

when determining component voltage ratings, conductor current ratings, fuse sizes, and

size of controls connected to the PV output."

●Refer to Section 690-8 of the National Electrical Code for an additional multiplying

factor of 125 percent (80 percent derating) which may be applicable.

Product identification

Each module has three labels on its rear and front sides providing the following

information:

●Nameplate: describes the product type; rated power, rated current, rated voltage, open

circuit voltage, short circuit current, all as measured under standard test conditions;

dimension etc., the maximum system voltage for TUV listed modules is 1000 volts DC and

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

5

QJ

is shown on the nameplate.

●Barcode: each individual module has a unique serial number. There are two barcodes on

module. One is permanently attached to the interior of the module visible when viewing

from the front of the module. This barcode is inserted at the beginning of laminating.

●Do not remove any label. If the label is removed, the product warranty will no longer be

honored by QJ.

Mechanical Installation

● Selecting the location

⊙Select a suitable location for installation of the module.

⊙The module should be facing true south in northern latitudes and true north in southern

latitudes for best power production.

⊙For detailed information on the best elevation tilt angle for the installation, refer to

standard solar photovoltaic installation guides or a reputable solar installer or systems

integrator.

⊙The module should not be shaded at any time of the day.

⊙Do not use module near equipment or in locacollected.

●Selecting the proper support frame

⊙Always observe the instructions and safety precautions included with the support frame

to be used with the module.

⊙No attempt must be made to drill holes in the glass surface of the module. To do so will

void the warranty.

⊙Do not drill additional mounting holes in the frame of the module. Doing so will void the

warranty.

⊙Modules must be securely attached to the mounting structure using four mounting points

for normal installation. If additional wind or snowloads are anticipated for this installation,

additional mounting points are also used. Refer to the drawing, below, load calculations are

left to the system designer or installer.

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

6

QJ

⊙The support module mounting structure must be made of durable, corrosion-resistant

and UV-resistant material..

●Ground mount

⊙Select the height of the mounting system to prevent the lowest edge of the module from

being covered by snow for a long time in winter in areas that experience heavy snowfalls.

In addition, assure the lowest portion of the module is placed high enough so that it is not

shaded by plants or trees or damaged by sand and stone driven by wind.

●Roof mount

⊙When installing a module on a roof or building, ensure that it is securely fastened and

cannot fall as a result of wind or snow loads.

⊙Provide adequate ventilation under a module for cooling (5cm minimum air space

between module and mounting surface).

⊙When installing module on a roof, ensure that the roof construction is suitable. In

addition, any roof penetration required to mount the module must be properly sealed to

prevent leaks.

⊙In some cases, a special support frame may be necessary.

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

7

QJ

⊙The roof installation of solar modules may affect the fireproofing of the house

construction.

⊙The modules are rated fire Class C, and are suitable for mounting over a Class A roof.

⊙To maintain the corresponding fire prevention level, the tilt angle should be no less

than 5 in/ft (127 mm/305 mm) when the modules are mounted on the roof.

⊙The National Electric Code required the use of a properly sized GFDI on photovoltaic

arrays installed on dwellings. Refer to the NEC for further information on earth ground

fault breakers.

For field connections, use minimum 12 AWG copper wires insulated for a minimum of

90 °C.

Recommended maximum series/parallel module configurations; ([1000

V/(1.25*Voc)]/[fuse rating/Isc+1],如 QJP300-72,Voc is43.4V,Ifuse is15A,Isc is 9.27A,

for 72 cells modules series,Recommended maximum series/parallel module

configuration :18/2.

⊙When installing the module on a roof or building, do so in calm winds. Installing a

module during strong winds may cause accidents.

Mechanical Installation

●Pole mount

⊙When installing a module on a pole, choose a pole and module mounting

structure that will withstand anticipated winds for the area.

●General installation

⊙Module mounting must use the pre-drilled mounting holes in the frame.

⊙The most common mounting is achieved by mounting the module using the four

symmetry points close to the inner side on module frame.

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

8

QJ

⊙If excessive wind or snow loads are expected, all eight mounting holes must be used.

⊙Do not lift the module by grasping the module’s junction box or electrical leads.

⊙Do not stand or step on module.

⊙Do not drop module or allow objects to fall on module.

⊙To avoid glass breakage, do not place any heavy objects on the module.

⊙Do not set the module down hard on any surface.

⊙Inappropriate transport and installation may break the glass of the module.

Electrical Installation

●Grid-connected electrical system

⊙The DC electrical energy generated by photovoltaic systems may also be converted to AC

and connected to a utility grid system. As local utilities’ policies on connecting renewable

energy systems to their grids vary from region to region, consult a qualified system

designer or integrator to design such a system. Permits are normally required to install such

a system and the utility must formally approve and inspect such a system before it can be

connected to the grid.

●Grounding

⊙The module frame must be properly grounded (refer to NEC clause 250). The grounding

wire must be properly fastened to the module frame to assure good electrical contact. Use

the recommended type, or an equivalent, connector for this wire.

⊙If the support frame is made of metal, the surface of the frame must be electroplated and

have excellent conductivity.

⊙We recommend the lay-in lug (Cat.No.GBL4-DBT;company:ILSCO) when grounding.

First strip 16mm insulating jacket from the end of the ground wire (4-14STR) carefully to

avoid nicking or cutting conductors, insert the wire into the slot of the lug (see the picture),

and screw down the slotted screw.

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

9

QJ

Electrical Installation

Next assemble the recommended ILSCO grounding lug to the aluminum frame using

stainless steel M3 or M5 screw and hardware as shown below. Note: there are two different

size grounding holes, the smaller of which is being phased out. Further, buildup of

hardware for mounting the grounding lug are the same---except for the M3 screw, and

added flat washer is mounted directly under the M3 screw head. The star waher is fitted

directly under the grouding lug and makes electrical contact by penetrating the anodized

coating of the aluminum frame. The screw assembly is further fitted with a flat washer,

then a split lock washer and finally a nut to secure the entire assembly, as shown.

Recommended torque of M3 or M5 screw assembly is 0.8NM or 1.5NM.

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

10

QJ

Electrical Installation

●General installation

⊙Do not use module of different configurations in the same system.

⊙Several modules are connected in series and then in parallel to form a PV array,

especially for application with a high operation voltage. If modules are connected in series,

the total voltage is equal to the sum of individual voltages.

⊙For applications requiring high currents, several photovoltaic modules can be connected

in parallel; the total current is equal to the sum of individual currents.

⊙Module is supplied with Multicontact connectors(PV-KBT4 and PV-KST4) to use for

system electrical connections. Use the National Electric Code to determine system wiring

size (refer to NEC clause 310), type and temperature rating of conductors to be connected

to the module’s connectors. Wiring connected to the module’s wiring should be #12AWG

(minimum) and must be temperature rated at 90℃ (minimum).

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

11

QJ

⊙In Canada installation shall be in accordance with CSA C22.1, Safety Standard for

Electrical Installations, Canadian Electrical Code, Part1.

⊙The cross section area of cable and the capacity of connector must be selected to suit the

maximum system short circuit current, otherwise the cable and connector will be

overheated under large current. Refer to NEC for details.

⊙Module overcurrent protection, rated for DC use.

⊙The junction box is fitted with a breather port. The breather port must be mounted facing

down and can not be exposed to rain. Therefore, the junction box must be on the higher

side of the module when it is mounted.

Commission and Maintenance

QJ recommends that all work in commissioning and maintenance of a system must be

performed by a qualified solar PV technician.

●Blocking diodes and bypass diode

⊙Blocking diodes prevent current flowing from the battery to the module when no

electricity is being generated. It is recommended to use blocking diodes when a charging

regulator is not used. Your specialist dealer can advise you with regards to suitable types,

such as Schottky diodes.

⊙In systems with more than two modules in series, high reverse current can flow through

cells that are shaded partially or outright when part of a module is shaded and the rest is

exposed to the sun. These currents can cause the affected cells to get very hot and could

even damage the module. To protect module from such high reverse currents, by-pass

diodes are used in module. All modules rated greater then 55 watt have bypass diode

already integrated in the junction box. In the unlikely event of diode failure, OVIERA

recommends a qualified service technician be employed to determine if diodes have failed

and to make replacement.

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

12

QJ

⊙Protect yourself against electricity shocks while commissioning and maintaining the solar

power system.

●Testing, commissioning and troubleshooting

Test all electrical and electronic components of your system before commissioning it.

Follow the instructions in the guides supplied with the components and equipment.

⊙Testing modules connected in series before they are connected to system. To determine

Voc and Isc in the following tests, the module(s) must be exposed to the sun and not

connected to a load. Observe personal safety when making these measurements.

⊙Check the open-circuit voltage (Voc) of every series module using a digital multimeter

(Fluke 170 series are recommended). The measured system Voc should correspond to the

sum of the Vocs of the individual module. You will find the rated voltage in the technical

specifications of the type of the module used and in the tables at the end of this installation

guide. If the measured value is significantly lower than the expected value, proceed as

described under “Troubleshooting an excessively low voltage”.

⊙Determine the short-circuit current (Isc) of every series circuit. It can be measured

directly by connecting the digital multimeter connected in the two terminals of series

circuit or module. Attention, the rated scale of the ammeter or the rated current of load

should more than 1.25 times than the rated short-circuit current of series module. You will

find the rated current in the technical specifications of the type of module used. The

measured value can vary significantly, depending on weather conditions, the time of day

and shading of the module.

⊙Troubleshooting low voltages

To identify the commonly low voltage and excessively low voltage, the commonly how

voltage mentioned here is the decrease of open-circuit voltage of the module, which is

caused by the temperature rising of solar cells or lower irradiance. Excessively low voltage

is typically caused by improper connections at the terminals or defective bypass diodes.

Commission and Maintenance

⊙First check all wiring connections to make sure it is not open-circuit or is not connection

well.

⊙Check the open-circuit voltage of each module.

⊙Fully cover the modules with an opaque material.

⊙Disconnect the wiring at both terminals of the modules.

⊙Remove the opaque material from the module to be checked and measure the open-circuit

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

13

QJ

voltage at its terminals.

⊙If the measured voltage is only half of the rated, this indicates a defective bypass diode.

Refer to “Testing and replacing bypass diodes”.

⊙In the case of not very low irradiance, if the voltage across the terminals differs from the

rated value by more than 5 percent, this indicates a bad electrical connection.

●Maintenance

QJ recommends the following maintenance in order to ensure optimum performance of the

module.

⊙Clean the glass surface of the module as necessary. Always use water and a soft sponge

or cloth for cleaning. A mid, non-abrasive cleaning agent can be used to remove stubbom

dirt.

⊙Check the electrical and mechanical connections every six months to verify that they are

clean, secure and undamaged.

⊙If any problem arises, have them investigated by a competent specialize. Observe the

maintenance instructions for all components used in the system, such as support frames,

charging regulators, inverters, batteries, etc.

●Testing and replacing bypass diodes

Removing the bypass diodes should be done only by a competent PV technician and after

the module has been disconnected from the system.

⊙Place module face down on a soft, flat surface insert a 3mm flat screwdriver into the slot

on the junction box cover. (The cover has a sign of screwdriver). Gently pull up the four

slots until the cover been opened.

⊙Insert the 3mm flat screwdriver into a hole alongside of diode and near one mounting

hole of the diode, pry the screwdriver in the opposite direction of diode and gently pull the

diode up until the lead comes free. Do the same in the other mounting hole of the diode,

and repeat until the diode is free.

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

14

QJ

Commission and Maintenance

●Note the orientations of the polarity markings on the diodes.

●Check the resistance of the diodes by using the digital multimeter’s ohms scale.

Resistance should be low in one direction, then when leads are reversed on the diode’s

terminals the resistance should be high, as illustrated in the two pictures below. If a diode

has a low resistance in both directions, it is probably shorted. If it has high resistance in

both directions it is probably open. In either case it should be replaced.

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

15

QJ

●Replace a defective diode with a diode of the same type, and ensure that its polarity

making is oriented the same way as the original diode.

●Finally, check the open-circuit voltage (Voc) of the module, as described previously, and

replace both covers.

Disclaimer of liability

●Because the use of this manual and the conditions or methods of installation, operation,

use and maintenance of photovoltaic (PV) product are beyond QJ’s control, QJ does not

accept responsibility and expressly disclaims liability for loss, damage, or expense arising

out of or in any way connected with such installation, operation , use or maintenance.

●No responsibility is assumed by QJ for any infringement of patens or other rights of third

parties, which may result from use of the PV product. No license is granted by implication

or otherwise under any patent or patent rights.

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

16

QJ

●The information in this manual is based on QJ knowledge and experience and is believed

to the reliable; but such information including product specification (without limitations)

and suggestions do not constitute a warranty, expresses or implied. QJ reserve the right to

change the manual, the PV produce, the specifications, or product information sheets

without prior notice.

Electrical Characteristics

Please refer to QJ Catalogue.

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

17

QJ

products catalogue

Maximum System Voltage: 1000VDC

Power Tolerance: ±3%

Application classes: Class A

Class A: General access, hazardous voltage, hazardous power applications

Modules rated for use in this application class may be used in systems operating at greater

than 50 V DC or 240 W, where general contact access is anticipated. Modules qualified for

safety through this part of IEC 61730 and IEC 61730-2 and within this application class are

considered to meet the requirements for safety class II.

Model Module

Dimensions

Weigh

t

Isc Voc Imp Vmp Pmax Maxi

mum

serie

s

Fuse

Rain

g

QJP335 1956x992x40

(mm)

20.3kg 9.69A 44.4V 9.06A 37V 335W 15A

QJP330 1956x992x40

(mm)

20.3kg 9.58A 44.28V 8.95A 36.9V 330W 15A

QJP325 1956x992x40

(mm)

20.3kg 8.91A 44.16V 8.32A 36.8V 325W 15A

QJP320 1956x992x40 20.3kg 9.33A 44.04V 8.72A 36.7V 320W 15A

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

18

QJ

(mm)

QJP315 1956x992x40

(mm)

20.3kg 9.22A 43.92V 8.61A 36.6V 315W 15A

QJP310 1956x992x40

(mm)

20.3kg 9.11A 43.8V 8.5A 36.5V 310W 15A

QJP305 1956x992x40

(mm)

20.3kg 8.97A 43.68V 8.38A 36.4V 305W 15A

QJP300 1956x992x40

(mm)

20.3kg 8.85A 43.56V 8.27A 36.3V 300W 15A

QJP295 1956x992x40

(mm)

20.3kg 8.72A 43.44V 8.15A 36.2V 295W 15A

QJP290 1956x992x40

(mm)

20.3kg 8.61A 43.32V 8.04A 36.1V 290W 15A

QJP285 1956x992x40

(mm)

20.3kg 8.48A 43.2V 7.92A 36.0V 285W 15A

QJP280 1640x992x40

(mm)

18.2kg 9.71A 37.08V 9.07A 30.9V 280W 15A

QJP275 1640x992x40

(mm)

18.2kg 9.56A 36.96V 8.93A 30.8V 275W 15A

QJP270 1640x992x40

(mm)

18.3kg 9.41A 36.84V 8.8A 30.7V 270W 15A

QJP265 1640x992x40

(mm)

18.3kg 9.27A 36.72V 8.66A 30.6V 265W 15A

QJP260 1640x992x40

(mm)

18.3kg 9.13A 36.6V 8.53A 30.5V 260W 15A

QJP255 1640x992x40

(mm)

18.3kg 8.98A 36.48V 8.39A 30.4V 255W 15A

Model Module

Dimensions

Weigh

t

Isc Voc Imp Vm

p

Pmax Maximu

m series

Fuse

Raing

QJP250 1640x992x40

(mm)

18.3kg 8.83A 36.36V 8.26A 30.3

V

250W 15A

QJP245 1640x992x40

(mm)

18.3kg 8.68A 36.24V 8.12A 30.2

V

245W 15A

QJP240 1640x992x40

(mm)

18.3kg 8.54A 36.12V 7.98A 30.1

V

240W 15A

QJP235 1640x992x40

(mm)

18.3kg 8.39A 36V 7.84A 30.0

V

235W 15A

QJP230 1640x992x40

(mm)

18.3kg 8.24A 35.88V 7.7A 29.9

V

230W 15A

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

19

QJ

QJP225 1640x992x40

(mm)

18.3kg 8.08A 35.76V 7.56A 29.8

V

225W 15A

QJP220 1325*992*40

(mm)

14.5kg 9.53A 29.64V 8.91 A 24.7

V

220W 15A

QJP215 1325*992*40

(mm)

14.5kg 9.36A 29.52V 8.74 A 24.6

V

215W 15A

QJP210 1325*992*40

(mm)

14.5kg 9.18A 29.4 V 8.58 A 24.5

V

210W 15A

QJP205 1325*992*40

(mm)

14.5kg 8.99A 29.28V 8.41 A 24.4

V

205W 15A

QJP200 1325*992*40

(mm)

14.5kg 8.81A 29.16V 8.23 A 24.3

V

200W 15A

QJP195 1325*992*40

(mm)

14.5kg 8.62A 29.04V 8.06 A 24.2

V

195W 15A

QJP190 1325*992*40

(mm)

14.5kg 8.44A 28.92V 7.89A 24.1

V

190W 15A

QJP165 1480*675*40

(mm)

11.5kg 9.49A 22.32V 8.87A 18.6

V

165W 15A

QJP160 1480*675*40

(mm)

11.5kg 9.26A 22. 2V 8.65A 18.5

V

160W 15A

QJP155 1480*675*40

(mm)

11.5kg 9.02A 22.08V 8.43A 18.4

V

155W 15A

QJP150 1480*675*40

(mm)

11.5kg 8.78A 21.96V 8.2A 18.3

V

150W 15A

QJP145 1480*675*40

(mm)

11.5kg 8.53A 21.84V 7.97A 18.2

V

145W 15A

QJP140 1480*675*40

(mm)

11.5kg 8.28A 21.72V 7.74A 18.1

V

140W 15A

QJP110 1008*675*40

(mm)

7.9kg 9.49A 14.88V 8.87A 12.4

V

110W 15A

QJP105 1008*675*40

(mm)

7.9kg 9.14A 14.76V 8.54A 12.3

V

105W 15A

QJP100 1008*675*40

(mm)

7.9kg 8.78A 14.64V 8.2A 12.2

V

100W 15A

QJP95 1008*675*40

(mm)

7.9kg 8.41A 14.52V 7.86A 12.1

V

95W 15A

QJP90 850*675*40

(mm)

6.96kg 9.36A 12.36V 8.74A 10.3

V

90W 15A

QJP85 850*675*40

(mm)

6.96kg 8.92A 12.24V 8.34A 10.2

V

85W 15A

QJP80 850*675*40

(mm)

6.96kg 8.48A 12.12V 7.93A 10.1

V

80W 15A

QJP75 690*675*40 5.86kg 9.67A 9.96V 9.04A 8.3 75W 15A

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

20

QJ

(mm) V

QJP70 690*675*40

(mm)

5.86kg 9.14A 9.84V 8.54A 8.2

V

70W 15A

QJP65 690*675*40

(mm)

5.86kg 9.72A 8.6V 8.03A 8.1

V

65W 15A

QJP55 535*675*40

(mm)

4.72kg 9.49A 7.44V 8.87A 6.2

V

55W 15A

QJP50 535*675*40

(mm)

4.72kg 8.78A 7.32V 8.2A 6.1

V

50W 15A

QJP45 535*675*40

(mm)

4.72kg 8.03A 7.2V 7.5A 6.0

V

45W 15A

QJP35 376*675*40

(mm)

3.66kg 8.92A 5.04V 8.34A 4.2

V

35W 15A

QJP30 376*675*40

(mm)

3.66kg 7.83A 4.92V 7.32A 4.1

V

30W 15A

QJP25 535*356*40

(mm)

2.91kg 8.63A 3.72V 8.07A 3.1

V

25W 15A

QJP20 535*356*40

(mm)

2.91kg 7.14A 3.6V 6.67A 3.0

V

20W 15A

QJP10 220*356*40

(mm)

1.6kg 10.3A 1.25V 9.62A 1.04

V

10W 15A

QJM355 1956*992*40

(mm)

20.2kg 10.3A 44.4V 9.59A 37V 355W 15A

QJM350 1956*992*40

(mm)

20.2kg 10.15

A

44.28V 9.49A 36.9

V

350W 15A

QJM345 1956*992*40

(mm)

20.2kg 10.03

A

44.16V 9.38A 36.8

V

345W 15A

QJM340 1956*992*40

(mm)

20.2kg 9.92A 44.04V 9.27A 36.7

V

340W 15A

QJM335 1956*992*40

(mm)

20.2kg 9.79A 43.92V 9.16A 36.6

V

335W 15A

QJM330 1956*992*40

(mm)

20.2kg 9.68A 43.8V 9.04A 36.5

V

330W 15A

QJM325 1956*992*40

(mm)

20.2kg 9.56A 43.68V 8.93A 36.4

V

325W 15A

QJM320 1956*992*40

(mm)

20.2kg 9.44A 43.56V 8.82A 36.3

V

320W 15A

QJM315 1956*992*40

(mm)

20.2kg 9.32A 43.44V 8.71A 36.2

V

315W 15A

QJM310 1956*992*40

(mm)

20.2kg 9.19A 43.32V 8.59A 36.1

V

310W 15A

QJM305 1956*992*40

(mm)

20.2kg 9.07A 43. 2V 8.48A 36.0

V

305W 15A

QJM295 1640*992*40 18.1kg 10.22 37.08V 9.55A 30.9 295W 15A

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

21

QJ

(mm) A V

QJM290 1640*992*40

(mm)

18.1kg 10.08

A

36.96V 9.42A 30.8

V

290W 15A

QJM285 1640*992*40

(mm)

18.1kg 9.93A 36.84V 9.28A 30.7

V

285W 15A

QJM280 1640*992*40

(mm)

18.1kg 9.79A 36.72V 9.15A 30.6

V

280W 15A

QJM275 1640*992*40

(mm)

18.1kg 9.65A 36.6V 9.02A 30.5

V

275W 15A

QJM270 1640*992*40

(mm)

18.1kg 9.51A 36.48V 8.89A 30.4

V

270W 15A

QJM265 1640*992*40

(mm)

18.1kg 9.36A 36.36V 8.75A 30.3

V

265W 15A

QJM260 1640*992*40

(mm)

18.1kg 9.22A 36.24V 8.61A 30.2

V

260W 15A

QJM255 1640*992*40

(mm)

18.1kg 9.07A 36.12V 8.48A 30.1

V

255W 15A

QJM250 1580x1066x5

0(mm)

21kg 5.81A 57.8V 5.19A 48.2

V

250W 10A

QJM245 1580x1066x5

0(mm)

21kg 5.71A 57.7V 5.10A 48.1

V

245W 10A

QJM240 1580x1066x5

0(mm)

21kg 5.61A 57.6V 5.01A 48.0

V

240W 10A

QJM235 1325*992*40

(mm)

14.4kg 10.18

A

29.64V 9.52A 24.7

V

235W 15A

QJM230 1325*992*40

(mm)

14.4kg 10.01

A

29.52V 9.35A 24.6

V

230W 15A

QJM225 1325*992*40

(mm)

14.4kg 9.83A 29.4V 9.19A 24.5

V

225W 15A

QJM220 1325*992*40

(mm)

14.4kg 9.65A 29.28V 9.02A 24.4

V

220W 15A

QJM215 1325*992*40

(mm)

14.4kg 9.47A 29.16V 8.85A 24.3

V

215W 15A

QJM210 1325*992*40

(mm)

14.4kg 9.29A 29.04V 8.68A 24.2

V

210W 15A

QJM205 1325*992*40

(mm)

14.4kg 9.11A 28.92V 8.51A 24.1

V

205W 15A

QJM200 1325*992*40

(mm)

14.4kg 8.92A 28.8V 8.34A 24

V

200W 15A

QJM195 1580x808x50

(mm)

15.5kg 6.01A 43.6V 5.37A 36.4

V

195W 10A

QJM190 1580x808x50

(mm)

15.5kg 5.86A 43.5V 5.23A 36.3

V

190W 10A

QJM185 1580x808x50 15.5kg 5.72A 43.4V 5.11A 36.2 185W 10A

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

22

QJ

(mm) V

QJM180 1580x808x50

(mm)

15.5kg 5.59A 43.3V 4.99A 36.1

V

180W 10A

QJM175 1480*675*40

(mm)

11.4kg 10.13

A

22.2V 9.46A 18.5

V

175W 15A

QJM170 1480*675*40

(mm)

11.4kg 9.89A 22.08V 9.24A 18.4

V

170W 15A

QJM165 1480*675*40

(mm)

11.4kg 9.65A 21.96V 9.02A 18.3

V

165W 15A

QJM160 1480*675*40

(mm)

11.4kg 9.41A 21.84V 8.8A 18.2

V

160W 15A

QJM155 1480*675*40

(mm)

11.4kg 9.17A 21.72V 8.57A 18.1

V

155W 15A

QJM130 1074x808x50

(mm))

11kg 5.96A 29.3V 5.32A 24.4

V

130W 10A

QJM125 1074x808x50

(mm))

11kg 5.79A 29.0V 5.17A 24.2

V

125W 10A

QJM120 1074x808x50

(mm))

11kg 5.60A 28.8V 5.01A 24.0

V

120W 10A

QJM115 1008*675*40

(mm))

7.8kg 9.93A 14.88V 9.28A 12.4

V

115W 15A

QJM110 1008*675*40

(mm))

7.8kg 9.58A 14.76V 8.95A 12.3

V

110W 15A

QJM105 1008*675*40

(mm))

7.8kg 9.21A 14.64V 8.61A 12.2

V

105W 15A

QJM100 1008*675*40

(mm))

7.8kg 8.85A 14.52V 8.27A 12.1

V

100W 15A

QJM95 850*675*40

(mm))

6.9kg 9.87A 12.36V 9.23A 10.3

V

95W 15A

QJM90 850*675*40

(mm))

6.9kg 9.45A 12.24V 8.83A 10.2

V

90W 15A

QJM85 850*675*40

(mm))

6.9kg 9.01A 12.12V 8.42A 10.1

V

85W 15A

QJM80 850*675*40

(mm))

6.9kg 8.56A 12V 8A 10

V

80W 15A

QJM75 690*675*40

(mm))

5.8kg 9.67A 9.96V 9.04A 8.3

V

75W 15A

QJM70 690*675*40

(mm))

5.8kg 9.14A 9.84V 8.54A 8.2

V

70W 15A

QJM65 690*675*40

(mm))

5.8kg 8.59A 9.72V 8.03A 8.1

V

65W 15A

QJM55 535*675*40

(mm))

4.65kg 9.49A 7.44V 8.87A 6.2

V

55W 15A

QJM50 535*675*40 4.65kg 8.78A 7.32V 8.2A 6.1 50W 15A

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

23

QJ

(mm)) V

QJM35 376*675*40

(mm))

3.6kg 8.92A 5.04V 8.34A 4.2

V

35W 15A

QJM30 376*675*40

(mm))

3.6kg 7.83A 4.92V 7.32A 4.1

V

30W 15A

QJM25 535*356*40

(mm))

2.85kg 8.63A 3.72V 8.06A 3.1

V

25W 15A

QJM10 220*356*40

(mm))

1.55kg 9.73A 1.32V 9.09A 1.1

V

10W 15A

QJM260-12

5

1580x1066x5

0(mm)

21kg 6.00A 58.2V 5.36A 48.5

V

260W 10A

QJM255-12

5

1580x1066x5

0(mm)

21kg 5.91A 58.0V 5.28A 48.3

V

255W 10A

QJM235-12

5

1580x1066x5

0(mm)

21kg 5.49A 57.4V 4.91A 47.9

V

235W 10A

QJM230-12

5

1580x1066x5

0(mm)

21kg 5.39A 57.3V 4.81A 47.8

V

230W 10A

QJM225-12

5

1580x1066x5

0(mm)

21kg 5.28A 57.2V 4.72A 47.7

V

225W 10A

QJM220-12

5

1580x1066x5

0(mm)

21kg 5.17A 57.0V 4.63A 47.5

V

220W 10A

QJM175-12

5

1580x808x50

(mm)

15.5kg 5.45A 43.1V 4.87A 35.9

V

175W 10A

QJM170-12

5

1580x808x50

(mm)

15.5kg 5.35A 42.7V 4.78A 35.6

V

170W 10A

QJM165-12

5

1580x808x50

(mm)

15.5kg 5.22A 42.5V 4.66A 35.4

V

165W 10A

QJM115-12

5

1074x808x50

(mm))

11kg 5.41A 28.8V 4.83A 23.8

V

115W 10A

QJM110-12

5

1074x808x50

(mm)

11kg 5.24A 28.2V 4.68A 23.5

V

110W 10A

QJM95-125 1200x552x50

(mm)

7.8kg 5.94A 21.5V 5.31A 17.9

V

95W 10A

QJM90-125 1200x552x50

(mm)

7.8kg 5.72A 21.1V 5.11A 17.6

V

90W 10A

QJM85-125 1200x552x50

(mm)

7.8kg 5.48A 20.9V 4.89A 17.4

V

85W 10A

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

24

QJ

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

25

QJ

Mounting Using Clamps on Long Edge of Module

QJ modules recommend to be mounted using clamps designed for solar modules as

shown in Figures 3.

A module should be attached on a mount or support structure rail by metal clamps.

The metal clamp should fulfill the following specifications:

Size: not less than 1.5”(38mm)width

Thickness: not less than 0.12”(3mm)

Material: Aluminum alloy

Recommendation of bolt torque range: 16N.m to 25N.m.

It is always recommmendable to position the clamps at the location of the holes in the

module’s frame.

Recommendation of clamps position range:Figure 4 for reference.

The Modules clamps must not contact the front glass or deform the frame in any

way.Avoid shading effects from the Modules clamps.Drainage holes on the Modules frame

must not be closed or obscured by the clamps.

Figure 5 to Figure 14 is just used for the 60 cells modules and the dimension is

1640*992*40mm.

The details of Part 1and Part 11 in from Figure 6 to Figure 14 is reference to Figure 6

For Figure 7 and Figure8,the PV modules are designed for a maximum fo 2400Pa wind

load.

For from Figure 9to Figure 14,the PV modules are designed for a maximium of 2400Pa

Wind load and 5400Pa withstand heavy accumulations of snow and ice.

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

26

QJ

QJ SOLAR

CIXI CITY RIXING ELECTRONICS CO.,LTD

Jietang Industrial Park,Tianyuan Town,Cixi City,Zhejiang Province,China

WWW.QJSOLAR.COM Email: [email protected] Tel: +86 13586844751 Fax: +86 574 63456148

27

QJ