2
Installation Instructions Flexseal Couplings Global leaders in Flexible Couplings, Drainage and Plumbing Systems www.flexseal.eu Flexseal GmbH, Hessenring 31, 37269 Eschwege T: +49 (0)5651 2296400 | F: +49 (0)5651 2296410 | E: [email protected] Tighten the clamp bands to the recommended torque in sequence accross the width of the coupling. *SC & LC- Start with the central shear band. Loosen the clamp bands and slide the coupling onto the first pipe. No lubricant required. *AC - Smallest pipe first. Make a mark on the second pipe, half a coupling’s width from the end to be jointed. Insert the second pipe up to the mark. Tamp the bedding under the pipe and re-tighten prior to backfilling. Standard Coupling (SC) Large Coupling (LC) Drain Coupling (DC) Adaptor Coupling (AC) Instructions 1 1 1* 2 2 2 3 3 3 4* 4 4 5 5 5 LC LC

Installation Instructions Flexseal Couplings · Installation Instructions Flexseal Bush. Global leaders in Flexible Couplings, Drainage and Plumbing Systems. Standard Coupling (SC)/Large

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Installation Instructions Flexseal Couplings · Installation Instructions Flexseal Bush. Global leaders in Flexible Couplings, Drainage and Plumbing Systems. Standard Coupling (SC)/Large

Installation Instructions Flexseal Couplings

Global leaders in Flexible Couplings, Drainage and Plumbing Systems

www.flexseal.euFlexseal GmbH, Hessenring 31, 37269 EschwegeT: +49 (0)5651 2296400 | F: +49 (0)5651 2296410 | E: [email protected]

Tighten the clamp bands to the recommended torque in sequence accross the width of the coupling.

*SC & LC- Start with the central shear band.

Loosen the clamp bands and slide the coupling onto the first pipe. No lubricant required.

*AC - Smallest pipe first.

Make a mark on the second pipe, half a coupling’s width from the end to be jointed.

Insert the second pipe up to the mark.

Tamp the bedding under the pipe and re-tighten prior to backfilling.

Standard Coupling (SC)Large Coupling (LC) Drain Coupling (DC) Adaptor Coupling (AC) Instructions

1 1 1*

2 2 2

3 3 3

4* 4 4

5 5 5

LC

LC

Page 2: Installation Instructions Flexseal Couplings · Installation Instructions Flexseal Bush. Global leaders in Flexible Couplings, Drainage and Plumbing Systems. Standard Coupling (SC)/Large

3

1

Installation Instructions Flexseal Bush

Global leaders in Flexible Couplings, Drainage and Plumbing Systems

Standard Coupling (SC)/Large Coupling (LC) & Bush (BC)

2

5

6

4

Loosen the clamp bands and slide the coupling onto the larger pipe. No lubricant required.

Slide the bush onto the smallest pipe, up to the marked point.

Measure the couplings’ width and mark both pipes half the couplings’ width from the end to be jointed.

Insert the smaller pipe up to the mark.

Tighten all of the bands on the coupling to the recommended torque in sequence accross the width of the coupling, starting with the central shear band.

Tamp the bedding under the pipe and re-tighten prior to backfilling.

Instructions

www.flexseal.euFlexseal GmbH, Hessenring 31, 37269 EschwegeT: +49 (0)5651 2296400 | F: +49 (0)5651 2296410 | E: [email protected]

V002SEPT15

LC

LC