11
SunMaxx Solar | Flush Mounting ConnectMaxx Mounting Systems Installation Instructions TitanPower Plus-SU2 Collector Flush Mounting

Installation Manual - Titan Power Plus-SU2 - Flush Mount(v2)

Embed Size (px)

Citation preview

Page 1: Installation Manual - Titan Power Plus-SU2 - Flush Mount(v2)

SunMaxx Solar | Flush Mounting

ConnectMaxx Mounting Systems

Installation Instructions

TitanPower Plus-SU2 Collector

Flush Mounting

Page 2: Installation Manual - Titan Power Plus-SU2 - Flush Mount(v2)

SunMaxx Solar | Flush Mounting

General mounting and security advice

To avoid optical interferences (fog, condensate) the TitanPower Plus-SU2 collector must be mounted at an

angle between 35 and 75 degrees. For the collector warranty to apply this must be applied.

Statics:

An adequate load capacity of the roof construction must be taken in consideration, because the connection

parts are fixed to the roof structure. In case of specific loads, high wind and/or snow pressures the valuation

of an expert has to be obtained. Please observe the local codes and rules for roof installations.

Lightning protection:

All metallic parts of the solar system must be connected to the ground by a copper cable with an area of at

least 16mm2 (AWG 5). If lightning protection is already in place the collector system can be connected

directly to it.

Protection against dirt and injury:

Never carry collectors at the pipe ends. Keep dry and clean! Don’t store collectors outdoors!

Rinsing, filling and maintenance:

During installation and setup of the collectors keep them covered to prevent damages. Please consider the

national rules and manufacturer instructions for the use of propylene glycol. Use only water-glycol mixtures

that are appropriate for solar thermal systems.

Operating parameters, maintenance:

The recommended operating pressure should be in a range between 36.3 and 43.5 PSI. The volumetric flow

rate is suggested between 5.28 and 18.5 gallons per 10.76 square feet per hour. Highest approved working

pressure is 47 psi. Solar collectors are usually maintenance-free but the solar system should be checked for

damages and irregularities yearly by a solar thermal installer.

Transport and handling:

Carry collectors with the glass side facing up. Don’t damage the pipe ends. Don’t throw any materials at the

glass plate and be careful of the glass edges. Never touch pipes in case of solar radiation to avoid the risk of

a severe burn

General:

The references shown make no pretence on completeness. In all cases you must comply with the national

rules for mounting, installing and operation of a solar system.

Page 3: Installation Manual - Titan Power Plus-SU2 - Flush Mount(v2)

SunMaxx Solar | Flush Mounting

Technical data

TitanPower Plus-SU2:

Dimensions: 79.4 x 38.78 x 3.03inch

Gross area: 21.42ft²

Aperture area: 20.17ft²

Dry Weight: 74.96 lbs

Liquid capacity: 0.26 gallons

Area needed for collector field

Attention: Circumferential additional approximately 5.91” of space is needed

Pressure Loss

Tm=20°C

Flow [l/h] 0 50 100 150 200 250

Pressure Loss [Pa] 0 564 1168 1811 2493 3215

Number of Collectors

Field Length

[inch]

1 38.78

2 78.82

3 118.86

4 158.89

5 198.94

6 238.98

7 279.02

8 319.06

9 359.09

10 399.13

TitanPower Plus-SU2

985mm / 38.78inch

20

17

mm

/

79

.4in

ch

TitanPower Plus-SU2

32mm 1.26inch

20

17

mm

/ 7

9.4

1in

ch

Field Length

Page 4: Installation Manual - Titan Power Plus-SU2 - Flush Mount(v2)

SunMaxx Solar | Flush Mounting

Flush Mounting Parts List

Component quantites vary depending how many collectors are being installed in series.

Component SKU Description Picture

ConnectMaxx-15100096 Socket Head Cap Screw M8x22

ConnectMaxx-18000305 End Cap PP, 40x40mm

ConnectMaxx-74010701-2120 Mounting Rail Medium 40x40, 7ft length

ConnectMaxx-74011003 Rail Connector Fixed for 40x40mm

ConnectMaxx-74022601 Adjustable Clamping Plate

ConnectMaxx-77000500 Standard Roof Mount

ConnectMaxx-77000501 Standard Roof Mount Flashing

ConnectMaxx-72201701 Rail Clamping Washer

ConnectMaxx-SDS25412 Simpson Strong drive screw 1/4x4.5 in

Page 5: Installation Manual - Titan Power Plus-SU2 - Flush Mount(v2)

SunMaxx Solar | Flush Mounting

Installing Mounting Hardware

Step 1: Plotting Mounting Coordinates

Step 2: Mounting Roof Hooks

Step 3: Attaching Rails

Step 4: Mounting the Collectors

Step 5: Connecting the Universal Connect Set

Step 6: Inserting Temperature Sensors

Roof Hooks represent an essential component of our universal roof mounting hardware. If installed correctly, the roof hook

flashing system provided by SunMaxx

Is waterproof

Is in compliance with all codes put forth by the National Roofing Contractors Association

Is secure against insects and vermin

Is capable of supporting TitanPower Plus-SU2 or ThermoPower VHP collectors at all recommended tilt angles

Will not reduce fire resistance below code

Will isolate roof and construction materials from the high temperatures generated by the collector array

Step 2: Attaching the Roof Hook to the Roof *Roof hooks must be installed no more than 48” apart along each rail*

a. Locate the first rafter and place the roof hook on the roof. Loosen the shingle above the roof hook and temporarily set the flashing in place. This is to make sure the placement of the roof hook is accommodating.

b. Using the Simpson Strong Drive screws, fasten the roof hook atop the shingle. There is no need to pre-drill holes.

c. Once again, loosen the shingle above and move flashing in place. There is no need to fasten the flashing down with roofing nails, but using roofing caulk is optional.

d. Repeat steps 1a through 1c making sure not to exceed 48” spans.

Step 1: Plotting Mounting Coordinates a. Decide the best position for the collector array based on shading, aesthetics, wind factors, etc. b. Determine your collector field length using the chart on page 3 c. Taking the rafters in consideration, mark the collector field length on the roof where the top rail will

be installed. A standard chalk line should work well. Be sure to mark a level line for aesthetics. d. Measure down the roof 79.41 inches (2017mm) from the upper line and mark a second line parallel to

the first. These two lines represent where each roof hook will be aligned and the rails will be installed.

79.41 inches

Do Not exceed 48“

1c

1d

Page 6: Installation Manual - Titan Power Plus-SU2 - Flush Mount(v2)

SunMaxx Solar | Flush Mounting

Step 3: Attaching the Rails a. Set the rail in position. The upper rail will be attached to the bottom side of the roof hook. The

lower rail will be attached to the upper side of the roof hook.

b. Place the clamping plate between the rail and roof hook. Make sure the sliding channel is face-up

and the grooved channel is facing the roof hook. Press the clamping plate into the grooved

channels.

c. Screw the M8 x 22mm socket bolt into the channel, attaching the rail to the roof hook.

d. Repeat 2a through 2c for each roof hook, making sure the rail is level.

e. Connect two rails by using the Rail Connect and M8 x 22mm bolts and attach the end caps

2b

2c

In cases where the flashing does not fit under

the above shingle, it may be necessary to

notch out the shingle.

Page 7: Installation Manual - Titan Power Plus-SU2 - Flush Mount(v2)

SunMaxx Solar | Flush Mounting

3b

3c

3d

3a

Page 8: Installation Manual - Titan Power Plus-SU2 - Flush Mount(v2)

SunMaxx Solar | Flush Mounting

3e

Step 4:Mounting the collectors a. Position panel(s) on the rails.

b. If there is more than one panel, loosely connect them together. Make sure to include the graphite washer.

c. Once the panel(s) are in the desired position, attach the adjustable clamping plate to the panel using the

Hex bolts included on the ends of the collector.

d. Attach the adjustable clamping plate to the rail, using the M8x22mm bolts.

e. Make sure to return and tighten the connections between the panels.

4b

4a

Page 9: Installation Manual - Titan Power Plus-SU2 - Flush Mount(v2)

SunMaxx Solar | Flush Mounting

Step 5: Connecting the Universal Connect Set a. Left to Right - Piping from bottom left to top right

b. Right to Left - Piping from bottom right to top left.

**The Hot Supply from the collector should be the shortest pipe run**

5a

Top Left of Collector Top Right of Collector

4c 4d

Page 10: Installation Manual - Titan Power Plus-SU2 - Flush Mount(v2)

SunMaxx Solar | Flush Mounting

Bottom Left of Collector Bottom Right of Collector

5b

Top Left of Collector Top Right of Collector

Bottom Left of Collector Bottom Right of Collector

Page 11: Installation Manual - Titan Power Plus-SU2 - Flush Mount(v2)

SunMaxx Solar | Flush Mounting

Step 6: Inserting Temperature Sensor a. Lightly assemble stainless steel compression nut and attach to the temperature sensor well. Insert

temperature sensor and tighten the compression nut so that the sensor wire is sealed.

Contact Us:

Headquarters/Sales Office 56 Broome Corp. Pkwy Conklin, NY, 13748 Training Facility/ Sales Office 2917 State Hwy 7 Bainbridge, NY 13733 Sales Office 2475 W. 2nd Avenue Denver, CO 80223

Phone: 1.877.SUNMAXX (1.877.786.6299)