Installation, Operation, & Maintenance Manual P (304) 273-5357 F (304) 273-2531 P.O. Box 490/43 Ritmore Dr. Ravenswood, WV 26164 [email protected] www.mustangsampling.com MODEL: MHR, MJTHR Mustang® Heated Regulators Manufactured by Valtronics Solutions Mustang Sampling, LLC ITS12ATEX17539 IECEx ETL 12.0005X

Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

  • Upload
    others

  • View
    22

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

Installation, Operation, & Maintenance Manual

P (304) 273-5357

F (304) 273-2531

P.O. Box 490/43 Ritmore Dr.

Ravenswood, WV 26164

[email protected]

www.mustangsampling.com

MODEL: MHR, MJTHR

Mustang® Heated Regulators

Manufactured by

Valtronics Solutions

Mustang Sampling, LLC

ITS12ATEX17539 IECEx ETL 12.0005X

Page 2: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

© 2015 Mustang Sampling, LLC.

All Rights Reserved.

Revision: 002.1

Issue Date: 5/1/2015

File Name: MIOM-HRGL

No part of this document may be reproduced or transmitted in any form or by any means, elec-

tronic, mechanical, photocopying, recording, or otherwise, without prior written permission of

Mustang Sampling, LLC.

Systems and equipment are subject of Patents: US7162933, AU2005260719, CA2573120,

EP05769462.2, US7882729, AU2006216870, CA2605119, CN200680013386.3, EP06735575.0.

Other Patents Pending

Mustang Sampling®, Mustang®, Pony®, Certiprobe®, Certicollar®, Mustang Intelligent Vapor-

izer Sampling System®, SoftView®, the Mustang Sampling® logo are all registered trademarks of

Mustang Sampling, LLC.. All other trademarks and copyrights are the property of their respective

owners.

Mustang Sampling, LLC

304-273-5357

P.O. Box 490

Ravenswood, WV 26164

[email protected]

www.mustangsampling.com

Page 3: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

Safety Warnings 2

Product Features 3

Technical Specifications 4

Installation Instructions 5

Operation Instructions 6

Maintenance Instructions 7

General Arrangement—MHR—Fig. 1 8

Product Dimensions—MHR—Fig. 2 9

General Arrangement—MJTHR—Fig. 3 10

Product Dimensions—MJTHR—Fig. 4 11

Electrical Schematic—120 vac—Fig. 5 12

Wiring Diagram—120 vac—Fig. 6 13

Electrical Schematic—208 vac—Fig. 7 14

Wiring Diagram—208 vac—Fig. 8 15

Electrical Schematic—230 vac—Fig. 9 16

Wiring Diagram—230 vac—Fig. 10 17

Electrical Schematic—24 vdc—Fig. 11 18

Wiring Diagram—24 vdc—Fig. 12 19

Product Dimensions & Parts—Controller—Fig. 13, Fig. 14 20

TABLE OF CONTENTS

Page 4: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

2

SAFETY WARNINGS

Failure to abide by any of the safety warnings

could result in serious injury or death.

Electrical power must be "OFF" before and during installation and maintenance or personal

injury may result.

Do not exceed any equipment pressure ratings.

MHR & MJTHR surface temperature will approach temperature limit specified in technical

specifications. Gloves may be required for set point adjustments.

Select a mounting location so that the enclosure will not be subjected to impact by heavy ob-

jects. Impacts can damage enclosed devices.

The hazardous location information specifying class and group listing of each instrument en-

closure is marked on the nameplate of each enclosure.

All unused conduit openings must be plugged. Plugs must be a minimum of 1/8" thick and

engage a minimum of 5 full threads.

Do not use Teflon® tape or pipe dope on gland connection to the hazardous area rated en-

closures.

Page 5: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

3

PRODUCT FEATURES

The Mustang® Heated Regulator (MHR) and Joule-Thomson Heated Regulator (MJTHR) are

designed to heat a gas sample to a customer specified temperature and pressure set point.

Liquid condensation from a single-stage pressure reduction is prevented through a two-stage

heating process.

The regulator body houses a thermocouple and cartridge heater for precisely maintaining the

gas sample temperature.. Through an innovative design comprised of a long flow path, the

heated regulators provide efficient heat transfer to the gas sample which overcomes any

Joule-Thomson cooling effect as a result of the pressure reduction.

Temperature control of the regulator is accomplished via a Watlow temperature controller.

Temperature input is from Type J thermocouple and the controllers utilize PI control to pro-

vide an output to the heater elements. Communication to the controller is via RS485 protocol.

The heated regulator assemblies provide safe and reliable temperature control and pressure

reduction essential to ensuring the performance of gas analyzers.

Analytically Accurate® design

Provides continuous gas sample conditioning in any process industry

Protects analyzers & helps preserve sample integrity

Efficient heat transfer through pre-heat and post-heat chambers

Proportional temperature control

Thermal cutoff

Contact us to determine heated and supercritical application needs with our Equations of

State software

Page 6: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

4

TECHNICAL SPECIFICATIONS

Classification Class 1, Div 1, Group C, D, & T3

Zone 1 Group IIC, Category 2G, IP66, Ex d IIC T3 Gb

MAOP MHR—3750 psig (259 BAR) @ 60ºF (16ºC)

MJTHR—6000 psig (408 BAR) @ 60ºF (16ºC)

Outlet Pressure Range 0-10, 2-25, 0-50, 0-100, 0-250, or 0-500 psig

(0-0.69, 0-1.72, 0-3.45, 0-6.89, 0-17.24, or 0-34.47 bar)

Internal Volume 5.0 cc

Control Range 0-140° C

Thermal Cut-Off Opens at 230° F (110° C) or 266° F (130° C) (customer specified)

Connections 1/4” FNPT—Process

3/4” FNPT—Conduit

Controller Watlow Model PM6C1EH-2AAAAA

Power 120 VAC—50/60 Hz, 215 W

208 VAC—50/60 Hz, 215 W

230 VAC—50/60 Hz, 215W

24 DC—24 VDC, 150W

Wetted Materials 316 SS/NACE Compliant; O-rings, Viton™, Other materials avail-able—consult factory.

Seat Material Teflon™

Certifications ITS12ATEX17539

IEC Ex ETL 12.000 5X

Page 7: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

5

INSTALLATION INSTRUCTIONS

NOMENCLATURE

MAOP—Maximum Allowable Operating Pressure

BTU—British Thermal Unit

TCO—Thermal Cut Off

Watlow Controller—temperature controller for the heated regulator

Regulator adjustment screw—pressure set point adjuster

Terminal Strip—location of internal wire landing points

Thermocouple—type of temperature sensor implemented

TOOLS REQUIRED

Flat or Phillips Head Screwdriver

The Mustang® Heated Regulator assembly can be mounted in any position. Preferred position is with the heater block at the bottom so heat can rise into the body of the regulator.

Mount the Model MHR assembly in accordance with previous cautions and warnings.

Perform the electrical hook up with de-energized conductors.

Verify the unit that you are hooking up to matches voltage wise with the power supply

that you are connecting. Damage to the unit can occur if the wrong source power is ap-

plied.

A seal fitting is required for the power input connection to the controller enclosure to main-

tain its electrical hazard classification rating.

For 120 volt single phase input power: Connect the “hot” wire to wiring terminal #1. Con-

nect the “Neutral” wire to wiring terminal #2. Connect the earthing (ground) wire to the

green screw in the bottom of the enclosure.

For 208 or 230 volt single phase input power: Connect one “hot” wire to wiring terminal

#1. Connect the “Neutral” to wiring terminal #2. Connect the second “hot” wire to wiring

terminal #3. Connect the earthing (ground) wire to the green screw in the bottom of the

enclosure.

For 24 vdc input power: Connect the positive wire to wiring terminal #1. Connect the nega-

tive wire to wiring terminal #2. Connect the earthing (ground) wire to the green screw in

the bottom of the enclosure.

Page 8: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

6

A seal fitting is required between the controller enclosure and the MHR heater block.

Externally connect earthing (grounding) conductors from assembly to equipment ground

connections.

Connections from the controller to the heater block are pre-wired from the factory. If re-

placement or troubleshooting is required, refer to the electrical schematic supplied with the

unit.

ADJUST THE TEMPERATURE SET POINT.

The temperature controller comes from the factory set to 120 F unless otherwise specified.

If a different temperature is required, refer to the Watlow Temperature Controller operation

manual for the complete setup and adjustment procedures.

SET REGULATOR PRESSURE

Apply input pressure and adjust the regulator adjustment screw until the desired output

pressure is attained. The nut on the adjustment screw may be used to secure the adjust-

ment screw at its set point.

OPERATION INSTRUCTIONS

Close the cover on the controller enclosure.

Turn on the electrical supply to the controller.

Allow a few minutes for the system temperature to stabilize.

The pressure set point may have to be adjusted once the temperature has stabilized.

Seal the seal fittings if the controller is functioning as desired.

Verify that the sample stream supply is shut off.

Verify that the power to the controller is off.

Install the Watlow supplied software (EZ-Zone Configurator) on a laptop or other computer.

Connect to the Watlow controller using a RS-485 adapter (B&B Electronics Model 485SD9

TB or equal). Plug the adapter into the serial port. Select the serial port on the computer to

be used (i.e. COM 1-COM17). The other end connects to the RS-485 terminals.

Page 9: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

7

On the computer, start program “EZ-Zone Configurator.”

Turn power on to the controller.

Establish communication with the Watlow controller.

Set its address to “1” or user preference.

Set the regulator temperature set point to the recommended temperature.

Initially set the regulator temperature at ___°F (___°C).

For all other Watlow parameter settings, refer to the EZ-Zone User’s Manual.

Slowly turn in the sample fluid low to full open to the regulator.

Adjust the regulator adjusting screw to obtain the desired output pressure.

Once sample fluid is being regulated, monitor the regulator temperature to verify that the

controller is maintaining the set point temperature.

Verify the pressure and flow to the remote gas chromatograph or analyzer.

Once the flow is correctly established to the analyzer or gas chromatograph, document the

flow value. Do not adjust the flow value unless a calibration check is made on the analyzer.

Do not leave power on for extended periods of time without flow through the unit.

MAINTENANCE INSTRUCTIONS

Once system is operational, no routine maintenance is required.

Monitoring of flow and temperature values is recommended at least annually.

Page 10: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

8

GENERAL ARRANGEMENT—MHR

HEAT EXCHANGE CHAMBER

REGULATOR

ADJUSTING SCREW

TEMPERATURE CONTROLLER IN

CLASS 1 DIV 1 & 2 ENCLOSURE

Page 11: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

9

PRODUCT DIMENSIONS —MHR

TOP VIEW

FRONT VIEW

Page 12: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

10

GENERAL ARRANGEMENT—MJTHR

TEMPERATURE CONTROLLER IN

CLASS 1 DIV 1 & 2 ENCLOSURE

MULTI-STAGE REGULATOR

ADJUSTING SCREW

HEAT EXCHANGE CHAMBER

Page 13: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

11

PRODUCT DIMENSIONS —MJTHR

TOP VIEW

FRONT VIEW

Page 14: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

12

ELECTRICAL SCHEMATIC—120 VAC

Page 15: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

13

WIRING DIAGRAM—120 VAC

Page 16: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

14

ELECTRICAL SCHEMATIC—208 VAC

Page 17: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

15

WIRING DIAGRAM—208 VAC

Page 18: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

16

ELECTRICAL SCHEMATIC—230 VAC

Page 19: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

17

WIRING DIAGRAM—230 VAC

Page 20: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

18

ELECTRICAL SCHEMATIC—24 VDC

Page 21: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

19

WIRING DIAGRAM—24 VDC

Page 22: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

20

PRODUCT DIMENSIONS & PARTS—CONTROLLER

Fig. 13—DWG# MST-UPH-##WTL-1.01

Page 23: Installation, Operation, & Maintenance Manual · OPERATION INSTRUCTIONS Close the cover on the controller enclosure. Turn on the electrical supply to the controller. Allow a few minutes

21

Specification for Temperature Controller Enclosure

Mustang Sampling®

Outlet box for hazardous locations

Class 1, Groups B, C, D

CE Ex 11 2 g Ex d llc. T6-30 Max, T5-40 Max Gb IP66

CAUTION: TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES,

DISCONNECT THE EQUIPMENT FROM THE SUPPLY CIRCUIT BEFORE OPENING.

OUVRIR LE CIRCUIT AVANT D;ENLEVER LE COUVERCLE

KEEP ASSEMBLY TIGHTLY CLOSED WHEN IN OPERATION.

GARDER LE COUVERCLEBIEN FERME TANT CUE LES CIRCUITS SONT SOUS TENSION.

Fig. 14—DWG# MST-UPH-WTLRG-AI-6.01