1
Installing a Kilroy I spring to assist the eruption of a palatally impacted tooth 1 With a utility plier such as a Weingart, pinch the helices at both ends of the spring and close slightly. (fig.1) 2 Thread the Kilroy I onto the archwire (see note) with the vertical loop to the buccal and extending to the occlusal. (fig.2) 3 Position the Kilroy I so that the terminal helices extend beyond the bracket or the teeth adjacent to the site for the impacted tooth. (fig.3) 4 Tie the archwire in place - tightly. 5 To activate the Kilroy, run a stainless steel ligature through the helix of the vertical loop. (fig.4) Direct the loop in the direction of the impacted tooth and tie to the receiving attachment on the impacted tooth. (fig.5) 6 Re-tie, as necessary, to bring the impacted tooth into position. Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Note: The Kilroy I uses support from the teeth adjacent to the im- paction site to generate its activation force. A rectangular archwire, 017 x 025 minimum is required to resist undesirable forces on these abutment teeth. In addition, these teeth must be tied in with stain- less steel ligatures. Do Not use elastic ligatures. REV8/12 EC Certification Service GbmH Sandgasse39a, A-9300 St. Veit/Glan, Austria

Installing a Kilroy I spring to assist the eruption of a ... · Installing a Kilroy I spring to assist the eruption of a palatally impacted tooth 1 With a utility plier such as a

  • Upload
    others

  • View
    36

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Installing a Kilroy I spring to assist the eruption of a ... · Installing a Kilroy I spring to assist the eruption of a palatally impacted tooth 1 With a utility plier such as a

Installing a Kilroy I spring to assist the eruption of a palatally impacted tooth

1 With a utility plier such as a Weingart, pinch the helices at both ends of the spring and close slightly. (fig.1)

2 Thread the Kilroy I onto the archwire (see note) with the vertical loop to the buccal and extending to the occlusal. (fig.2)

3 Position the Kilroy I so that the terminal helices extend beyond the bracket or the teeth adjacent to the site for the impacted tooth. (fig.3)

4 Tie the archwire in place - tightly.

5 To activate the Kilroy, run a stainless steel ligature through the helix of the vertical loop. (fig.4) Direct the loop in the direction of the impacted tooth and tie to the receiving attachment on the impacted tooth. (fig.5)

6 Re-tie, as necessary, to bring the impacted tooth into position.

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig. 5

Note: The Kilroy I uses support from the teeth adjacent to the im-paction site to generate its activation force. A rectangular archwire, 017 x 025 minimum is required to resist undesirable forces on these abutment teeth. In addition, these teeth must be tied in with stain-less steel ligatures. Do Not use elastic ligatures.