INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 3 of 51

COPY OF MARKING PLATE

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 4 of 51

6 Classification

6.1Appliances shall be of one of the following classeswith respect to protection against electric shock.Class 0, N/AClass 0I, N/A

Class I In compliance P

Class II N/A

Class III N/A

6.1Hand-held kitchen machines shall be class II orclass III. However, they may be class 0 or class Iif their rated voltage does not exceed 150 V.

N/A

6.2Appliances shall have the appropriate degree ofprotection against harmful ingress of water

N/A

7 Marking and instruction

7.1 Appliances shall be marked with the

- rated voltage or rated voltage range in volts. Rated Voltage 230 V P

- symbol for nature of supply, Provided P

- rated power input in watts or rated current inamperes,

Rated power Input : 650Watts

P

- name, trade mark or identification mark of themanufacturer

Provided P

- Model or type reference ‘MG-828’ P

- symbol 5172 of IEC 60417, for class IIappliances only;

Class I equipment N/A

- IP number according to degree of protectionagainst ingress of water other than IPX0

N/A

7.1Appliances shall be marked with their rated powerinput.

Provided (650 Watts) P

Stands provided with cordless blenders shall bemarked with

N/A

-the name, trademark or identification mark of themanufacturer or responsible vendor;

N/A

- the model or type reference N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 5 of 51

7.2Stationary appliances for multiple supply shall bemarked with the warning.

Single Supply Present N/A

Warning: Before obtaining access to terminals, allsupply circuits must be disconnected.

N/A

7.3Appliances having a range of rated values shallbe marked with the lower and upper limits of therange separated by a hyphen.

N/A

Appliances having different rated values andwhich have to be adjusted for use at a particularvalue by the user or installer shall be marked withthe different values separated by an obliquestroke.

N/A

7.4If the appliances can be adjusted for differentrated voltages, the voltage to which the applianceis adjusted shall be clearly discernible.

N/A

7.5

For appliances marked with more than one ratedvoltage or with one or more rated voltage ranges,the rated power input or rated current for each ofthese voltage or ranges shall be marked.

N/A

7.6 Symbols In Compliance P

7.7

Appliances to be connected to more than twosupply conductors and appliances for multiplesupply shall have a connection diagram fixed tothem, unless the correct mode of connection isobvious

N/A

7.8Except for type Z attachment, terminals used forconnection to the supply mains indicated asfollows:-- terminals intended exclusively for the neutralconductor shall be indicated by the letter N;

In compliance P

- protective earthing terminals shall be indicatedby symbol IEC 60417- 5019

In compliance P

These indications shall not be placed on screws,removable washers or other parts which can beremoved when conductors are being connected.

In Compliance P

7.9Switches which may give rise to a hazard whenoperated shall be marked so as to indicate clearlywhich part of the appliance they control.

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 6 of 51

7.10Stationary appliances and the different positionsof controls on all appliances shall be indicated byfigures, letters or other visual means.

In compliance P

The figure 0 shall not be used for any otherindication unless it is positioned and associatedwith other number so that it does not give rise toconfusion with the indication of the off position.

N/A

7.11Controls intended to be adjusted shall be providedwith an indication for the direction of adjustment.

Provided P

7.12Instructions for use shall be provided theappliance so that the appliance can be usedsafety.

Instruction manualProvided

P

7.12.1If it is necessary to take precautions duringinstallation of the appliance, appropriate detailsshall be given.

General operatingprecautions provided inthe instruction manual

P

7.12.2The instruction shall state that means fordisconnection must be incorporated in the fixedwiring in accordance with the wiring rules.

Appliance is providedwith a supply cord and aplug.

N/A

7.12.3

If the insulation of the fixed wiring supplying anappliance for permanent connection to the supplymains can come into contact with parts havingtemperature rise exceeding 50 K during test ofclause 11, the instruction shall state that the fixedwiring insulation must be protected.

Appliance is providedwith a supply cord and aplug.

N/A

7.12.4 Instructions for built-in appliances: N/A

- dimensions of the space to be provided for theappliances;

N/A

- dimensions and positions of the means forsupporting and fixing the appliance within thisspace

N/A

- minimum distances between the various parts ofthe appliance and the surrounding structure;

N/A

- minimum dimensions of ventilating openings andtheir correct arrangement;

N/A

- Connection of the appliance to the supply mainsand the interconnection of any separatecomponents.

N/A

- necessity to allow disconnection of the appliancefrom the supply after installation, unless theappliance incorporates a switch complying with24.3

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 7 of 51

7.12.5For appliances with type X attachment having aspecially prepared cord, the instructions shallcontain the substance of the following:

N/A

If the supply cord is damaged, it must be replacedby a special cord or assembly available from themanufacturer or its service agent.

N/A

For appliances with type Y attachment, theinstructions shall contain the substance of thefollowing.If the supply cord is damaged, it must be replacedby the manufacturer, its service agent or similarlyqualified persons in order to avoid a hazard

Provided P

For appliances with type Z attachment, theinstructions shall contain the substance of thefollowing.

N/A

The supply cord cannot be replaced. If the cord isdamaged the appliance should be scrapped.

N/A

7.12.6

The instruction for appliances incorporating a non-self-resetting thermal cut-out that is reset bydisconnection of the supply mains shall containthe substance of the following.

N/A

Caution: In order to avoid a hazard due toinadvertent resetting of the thermal cut-out, thisappliance must not be supplied through anexternal switching device, such as a timer, orconnected to a circuit that is regularly switched onand off by the utility.

N/A

7.12.7The instruction for fixed appliances shall statehow the appliances is to be fixed to its support.

N/A

12.2.8The instructions for appliances connected to thewater mains shall state

N/A

- the maximum inlet water pressure, in pascals N/A

- the minimum inlet water pressure, in pascals, ifthis is necessary for the correct operation of theappliance.

N/A

7.12The instructions shall include the operating timesand speed settings for accessories.

Provided P

Accessories, other than those supplied with theappliance, shall include instructions for theirsafe use.

P

The instructions for hand-held blenders shallinclude the substance of the following:

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 8 of 51

– always disconnect the blender from the supply ifit is left unattended and before assembling,disassembling or cleaning;

N/A

– do not allow children to use the blender withoutsupervision.

N/A

The instructions for centrifugal juicers shallinclude the substance of the following:

N/A

Do not use the appliance if the rotating sieve isdamaged

N/A

The instructions for cordless blenders shall statethat the blender is only to be used with the standprovided.

N/A

The instructions shall include details on how toclean surfaces in contact with food.

N/A

The instructions for appliances incorporating aswitch necessary for compliance with 22.40shall include the substance of the following:Switch off the appliance and disconnect fromsupply before changing accessories orapproaching parts that move in use.

Instruction is provided inthe manual

P

7.13Instruction and other text required by this standardshall be written in an official language of thecountry in which the appliance is to be sold.

In Compliance P

7.14The marking required by the standard shall beclearly legible and durable.

In compliance P

7.15The marking specified in 7.1 to 7.5 shall be on amain part of this appliance.

P

7.16

If compliance with this standard depends upon theoperation of a replaceable thermal link or fuselink, the reference number or other means foridentifying the link shall be marked at such a placethat it is clearly visible when appliance has beendismantled

No thermal link or fuseused

N/A

8 Protection against access to live parts

8.1Appliances shall be constructed and enclosed sothat there is adequate protection againstaccidental contact with the live parts

In Compliance P

8.1.1The requirement of 8.1 applies for all positions ofthe appliance when it is operated as in normaluse, and after the removal of detachable parts.

P

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 9 of 51

8.1.2

Test probe 13 of IEC 60132 is applied withoutappreciable force through openings in class 0appliances, class II appliances and class IIconstructions, except for those giving access tolamp caps and live parts in socket-outlets.

Class I appliance N/A

8.1.3

For appliances other than those of class II, testprobe 41 of IEC 61032 is applied withoutappreciable force to live parts of visibly glowingheating elements,

N/A

8.1.4 An accessible part is not considered to be live if

a)the part supplied at safety extra-low voltage,provided that

N/A

1)For a.c. the peak value of the voltage does notexceed 42.2 V,

N/A

2) For d.c. the voltage does not exceed 42.4V N/A

Or

If protective impedance is used, the currentbetween the part and the supply source shall notexceed 2 mA for d.c.

N/A

a) a.c. peak value shall not exceed 0.7 mA for a.c. N/A

- for voltages having a peak value over 42.4 V upto and including 450 V, the capacitance

N/A

- for peak values over 450 V up to and including15 kV, discharge not exceeding 45 μC

N/A

- for voltages having a peak value over 15 KV, theenergy is the discharge shall not exceed 350 mJ.

N/A

8.1.5

Live parts of built-in appliances, fixed applianceand appliances delivered in separate units, shallbe protected at least by basic insulation beforeinstallation or assembly.

N/A

8.2

Class II appliances and class II construction shallbe constructed and enclosed so that there isadequate protection against accidental contactwith basic insulation and metal parts separatedfrom live parts by basic insulation only.

N/A

It shall only be possible to touch parts which areseparated from live parts by double insulation orreinforced insulation

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 10 of 51

9 Starting of motor-operated appliances N/A

10 Power input and current

10.1

If an appliance is marked with rated power input,the power input at normal operating temperatureshall not deviate from the rated power input bymore than the deviation shown in table 1.

(Refer Table A) P

10.2

If an appliance is marked with rated current, thecurrent at normal operating temperature shall notdeviate from the rated current by more than thedeviation shown in Table 2.

N/A

11 Heating

11.1Appliances and their surroundings shall not attainexcessive temperatures in normal use.

In Compliance P

11.2Hand-held appliances are held in their normalposition of use.

N/A

Appliances with pins for insertion into socketoutlets are plugged into an appropriate wallmounted socket-outlet.

P

Built in appliances are installed in accordance withthe instruction

N/A

Other heating and other combined appliances areplaced in a test corner as follows.

N/A

11.3

Temperature rises, other than those of windings,are determined by means of fine-wirethermocouples positioned so that they haveminimum effect on the temperature of the partunder test.

In Compliance P

11.4Heating appliances are operated under normaloperation and at 1.15 times rated power input.

N/A

11.5

Motor-operated appliances are operated undernormal operation and supplied with the mostunfavorable voltage between 0.94 times and 1.06times the rated voltage.

P

11.6

Combined appliances are operated under normaloperation and supplied with the most unfavorablevoltage between 0.94 times and 1.06 times therated voltage.

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 11 of 51

11.7The appliance is operated for the period specifiedand where relevant the number of cyclesspecified.

P

11.7.101Bean slicers, churns, sieving machines and slicingmachines are operated for 30 min

N/A

11.7.102Berry-juice extractors, mincers and noodle makersare operated for 15 min.

N/A

11.7.103

Blenders that have to be kept switched on byhand and hand-held blenders are operated for 1min with the control adjusted to the highestsetting. The operation is carried out five times withrest periods of 1 min during which the mixture isreplaced.

N/A

11.7.104Can openers are operated until the can is fullyopen. This operation is carried out five times withrest periods of 15 s

N/A

11.7.105Centrifugal juicers having separate outlets for thejuice and residue are operated for 30 min.

N/A

11.7.106Cheese graters are operated until the cheese isgrated.

N/A

11.7.107

Citrus-fruit squeezers are operated for 15 s duringwhich two halves of fruit are squeezed. Theoperation is carried out 10 times with rest periodsof 15 s.

N/A

11.7.108

Coffee mills having a separate container forcollecting the ground coffee are operated until thecontainer is full, unless the hopper is emptied first.This operation is carried out twice with a restperiod of 1 min.

N/A

11.7.109Cream whippers and egg beaters are operated for10 min with the control adjusted to the highestsetting

N/A

11.7.110

Food mixers with beaters for mixing cake batterare operated for 15 min unless they incorporate abiased-off switch, in which case they areoperated for 5 min.

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 12 of 51

11.7.111

Food processors are operated with the setting ofthe control and for the period stated in theinstructions for mixing yeast dough. This operationis carried out five times or for a sufficient numberof times to process at least 1 kg of flour,whichever is less. However, at least twooperations are performed, with a rest period of 2min between each operation.

N/A

11.7.112

Grain grinders are operated until 1 kg of wheathas been ground. The hopper of batch-fedgrinders is refilled if necessary, with rest periodsof 30 s.

P

11.7.113Ice-cream machines for use in refrigerators andfreezers are operated for 5 min, after which thestirrer is stalled for 25 min.

N/A

11.7.114 Knife sharpeners are operated for 10 min. N/A

11.7.115

Knives are operated for 15 min. The slicingoperation is simulated at a rate of 10 slices perminute, the blades being unloaded for 2 s eachtime

N/A

11.7.116

Potato peelers of the container type are operateduntil the potatoes are adequately peeled. Potatoesmay be peeled in more than one batch. Peelingperiods are separated by rest periods for 2 min.

N/A

11.7.117Shredders and vegetable graters are operateduntil a batch of carrots is shredded. The operationis carried out five times with rest periods of 2 min.

N/A

11.8For ice-cream machines for use in refrigeratorsand freezers, the temperature rise values areincreased by 30 K.

N/A

11.8During the test, the temperature rises aremonitored continuously and shall not exceed thevalues shown in table 3.

(Refer Table B) P

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 13 of 51

13Leakage current and electric strength atoperating temperature

13.1At operating temperature, the leakage current ofthe appliance shall not be excessive and itselectric strength shall be adequate.

P

Heating appliances are operated at 1.15 times therated power input.

N/A

Motor-operated appliance and combinedappliance are supplied at 1.06 times ratedvoltage.

In compliance P

Protective impedance and radio interference filtersare disconnected before carrying out the tests.

N/A

13.2The leakage current is measured between anypole of the supply and accessible metal partsconnected to metal foil.

(Refer Table C)

P

After the appliance has been operated for aduration as specified in 11.7 the leakage currentshall not exceed

P

13.3 Electric strength test as per table 4

(Refer Table C)

P

No breakdown shall occur during the test. In compliance P

The appliance is disconnected from the supplyand the insulation is immediately subjected to avoltage having a frequency of 50 Hz or 60 Hz for 1min,

In compliance P

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 14 of 51

14. Transient Overvotlages

Appliance shall withstand the transient overvoltage to which they may be subjected.

(Refer Table C)

P

15 Moisture resistance

15.1

The enclosure of the appliance shall provide thedegree of protection against moisture inaccordance with the classification of theappliance.

N/A

15.1.1Appliances other than those classified IPX0 aresubjected to the test of IEC 60529.

N/A

Water valves containing live parts and that areincorporated in external hoses for connection ofan appliance to the water mains are subjected tothe test specified for IPX7 appliances.

N/A

15.1.2Hand held appliances are turned continuouslythrough the most unfavorable positions during thetest.

N/A

Built-in-appliances are installed in accordancewith the instructions.

N/A

Appliances normally used on the floor or table areplaced on a horizontal unperforated supporthaving a diameter of twice the oscillating tuberadius minus 15 cm

NA

For IPX3 appliances, the base of wall mountedappliances is placed at the same level as the pivotaxis of the oscillating tube

N/A

For IPX4 appliances, the horizontal centre line ofthe appliance is aligned with the pivot axis of theoscillating tube.

N/A

For wall mounted appliances state that theappliance is to be placed close to the floor leveland specifies a distances.

N/A

Appliances with type X attachment, except thosehaving a specially prepared cord, are fitted withthe lightest permissible type of flexible cord of thesmallest cross-sectional area specified in table 13.

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 15 of 51

15.2Appliances subject to spillage of liquid in normaluse shall be so constructed so that such spillagedoes not affect their electrical insulation.

N/A

15.3Appliances shall be proof against humidconditions that may occur in normal use.

N/A

16 Leakage current and electric strength. N/A

16.1The leakage current of the appliance shall not beexcessive and its electric strength shall beadequate.

N/A

Protective impedance is disconnected from liveparts before carrying out the tests.

N/A

16.2An a.c. test voltage is applied between live partsand accessible metal parts

N/A

The test voltage is.

- 1.06 times rated voltage, for single-phaseappliances.

N/A

- 1.06 times rated voltage, divided by √3, for three-phase appliances.

N/A

16.3 Electric strength test as per table 7

No breakdown shall observe during the test. N/A

The insulating is subjected to a voltage having afrequency of 50 Hz or 60 Hz for 1 min .

N/A

A test voltage is applied between accessible metalparts and the supply cord which is wrapped withmetal foil where it is located in an inlet bushing, acord guard or a cord anchorage.

N/A

17Overload protection of transformer andassociated circuitsAppliances incorporating circuits supplied from atransformer shall be constructed so that in theevent of short circuits which are likely to occur innormal use, excessive temperatures do not occurin the transformer or in the circuits associated withthe transformer.

No transformer used N/A

The temperature rise of the insulation of theconductor of safety extra-low voltage circuits shallnot exceed the relevant value specified in table 3by more than 15 K.

N/A

The temperature of windings shall not exceed thevalues specified in table 8.

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 16 of 51

18 Endurance N/A

19 Abnormal operation

19.1

Appliances shall be constructed so that as a resultof abnormal or careless operation, the risk of fire,mechanical damage impairing safety or protectionagainst electric shock is obviated as far aspracticable.

P

Electronic circuits shall be designed and appliedso that a fault condition will not render theappliance unsafe with regard to electric shock, firehazard, mechanical hazard dangerousmalfunction.

No electronic circuit used. N/A

Appliances incorporating heating elements aresubjected to the tests of 19.2 and 19.3.

N/A

Appliances incorporating motor are subject to thetests of 19.7 to 19.10.

19.1

The test of 19.7 is only applicable to berry-juiceextractors, food blenders, centrifugal juicers,churns, food mixers, food processors, ice-creammachines, mincers, and noodle makers.

N/A

-

Coffee mills that have to be kept switched on byhand, berry-juice extractors, food blenders,centrifugal juicers for fruit and vegetables, foodmixers, food processors and mincers areoperated for 30 s.

N/A

Grain grinders, noodle makers and other coffeemills are tested for 5 min.

P

19.2

Appliance with heating elements are tested underthe conditions of specified in clause 11 but withrestricted heat dissipation with power input of 0.85times rated power input normal operation.

N/A

19.3The test of 19.2 is repeated with power input 1.24time rated power input under normal operation.

N/A

19.4The appliance is tested under the conditionsspecified in clause 11.

N/A

19.5The test of 19.4 is repeated on class 01appliances and class I appliances incorporatingtubular sheathed or embedded heating elements.

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 17 of 51

19.6

Appliance with PTC heating elements aresupplied at rated voltage until steady conditionswith regard to power input and temperature areestablished.

N/A

19.7The appliance is operated under stalled conditionsby- locking the rotor if the locked rotor torque issmaller than the full load torque;

- locking moving parts of other appliances. N/A

19.7

Coffee mills that have to be kept switched on byhand, berry-juice extractors, food blenders,centrifugal juicers for fruit and vegetables, foodmixers, food processors and mincers areoperated for 30 s.

N/A

Grain grinders, noodle makers and other coffeemills are tested for 5 min

In compliance P

Churns and ice-cream machines are operateduntil steady conditions are established.

N/A

19.8

One phase of appliances incorporating three-phases motors is disconnected. The appliance isthen operated under normal operation andsupplied at rated voltage for the period in 19.7

N/A

19.9

A running overload test is carried out anappliances incorporating motor that are intendedto be remotely or automatically controlled or liableto be operated continuously.

N/A

19.10Appliances incorporating series motors areoperated with the lowest possible load andsupplied at 1.3 times rated voltage for 1 min.

N/A

The test is repeated with accessories in positionbut without additional load.

N/A

19.101Coffee mills and grain grinders are supplied atrated voltage and operated under normaloperation five times with rest periods

In Compliance P

19.102Coffee mills and grain grinders are subjected tothe following test that is carried out on threeadditional appliances

19.11

Electronic circuits are checked by evaluation ofthe fault conditions specified in 19.11.2 for allcircuits or parts of circuits, unless they complywith the conditions specified in 19.11.1.

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 18 of 51

19.11.1Fault conditions a) to f) specified in 19.11.2 arenot applied to circuits or parts of circuits whenboth of the following conditions are met;

N/A

- the electronic circuit is a low-power circuit asdescribed below;

N/A

- protection against electric shock, fire hazard,mechanical hazard or dangerous malfunction ofother parts of the appliances does not rely on thecorrect functioning of the electronic circuit.

N/A

19.11.2The fault conditions are considered and, ifnecessary, applied one at a time, consequentialfaults being taken into consideration;

N/A

a)Short circuit of functional insulation if clearancesor creepage distances are less than the valuesspecified in clause 29;

N/A

b) open circuit at the terminals of any component; N/A

c)Short circuit of capacitors, unless they complywith IEC 60384-14;

d)

Short circuit of any two terminals of an electroniccomponent, other than an integrated circuit. Thisfault condition is not applied between the twocircuits of an optocoupler

N/A

e) Failure of triacs in the diode mode;

f)

Failure of an integrated circuit. All possible outputsignals are considered for faults occurring withinthe integrated circuit. If it can be shown that aparticular output signal is unlikely to occur, thenthe relevant fault is not considered.

N/A

g)

Failure of an electronic power switching device isa partial turn-on mode with loss of gate control.During the test, winding temperatures shall notexceed the values given in 19.7.

N/A

19.11.3

If the appliance incorporates a protectiveelectronic circuit which operates to ensurecompliance with clause 19. The relevant test isrepeated with a single fault simulated. asindicated in a) to f) of 19.11.2

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 19 of 51

19.11.4

Appliances having a device with a off positionobtain by electronic disconnection or a device thatcan be placed in the stand-by mode, aresubjected to the tests of 19.11.4.1 to 19.11.4.7.the tests are carried out with the appliancesupplied at rated voltage, the device being set inthe off position or in the stand-by mode.

N/A

Appliances incorporating a protective electroniccircuit are subjected to the tests of 19.11.4.1 to19.11.4.7. The tests are carried

N/A

19.11.4.1

The appliance is subjected to electrostaticdischarges in accordance with IEC 61000-4-2 testlevel 4 being applicable. Ten discharges having apositive polarity ten discharges having a negativepolarity are applied at each preselected point.

N/A

19.11.4.2The appliance is subjected to radiated fields inaccordance with IEC 61000-4-3, test level 3 beingapplicable.

N/A

.11.4.3

The appliance is subjected to fast transient burstin accordance with IEC 61000-4-4. The test level3 is applicable for signal and control lines. Testlevel 4 is applicable for the power supply lines.The bursts are applied for 2 min with a positivepolarity and 2 min with a negative polarity.

N/A

19.11.4.4

The power supply terminals of the appliance aresubjected to voltage surges in accordance withIEC 61000-4-5, five positive impulses and fivenegative impulses being applied at the selectedpoints. Test level 3 is applicable for the line-to-line coupling mode, a generator having a sourceimpedance of 2 Ω being used. Test level 4 is applicable for the line-to-earth coupling mode, agenerator having a source impedance of 12 Ω being used.

N/A

19.11.4.5

The appliance is subjected to injected currents inaccordance with IEC 61000-4-6, test level 3 beingapplicable. During the test, all frequenciesbetween 0.15 MHz to 80 MHz are covered.

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 20 of 51

19.11.4.6

The appliance is subjected to the Class 3 voltagedips and interruptions in accordance with IEC61000-4-11. The values specified in Table 1 andTable 2 of IEC 61000-4-11 are applied at zerocrossing of the supply voltage.

N/A

19.11.4.7The appliance is subjected to mains signals inaccordance with IEC 61000-4-13, test level class2 being applicable.

N/A

19.12

If safety of the appliances depends upon theoperation of a miniature fuse-link complying withIEC 60127 during any of the fault conditionsspecified in 19.11.2, the test is repeated but withthe miniature fuse-link replaced by an ammeter, ifcurrent is measured.

N/A

- does not exceed 2.1 times the rated current ofthe fuse-link, the circuit is considered to beadequately protected; and the test is carried outwith the fuse-link short circuited.

N/A

- is at least 2.75 times the rated current of thefuse-link, the circuit is considered to beadequately protected.

N/A

- is between 2.1 times and 2.75 times the ratedcurrent of the fuse link, the fuse link is shortcircuited and the test is carried out.

N/A

19.13

During the tests the appliance shall not emitflames, molten metal, or poisonous or ignitablegas in hazardous amounts and temperature risesshall not exceed the values in table 9

N/A

For appliances which are immersed in or filledwith conducting liquid in normal, the appliance isimmersed in or filled with water for 24 h before theelectronic strength test is carried out.

N/A

The appliance shall not undergo a dangerousmalfunction, and there shall be no failure ofprotective electronic circuits if the appliance is stilloperable.

N/A

19.14

Appliances are operated under the conditions ofclause 11. Any contractor or relay contact thatoperates under the conditions of Clause 11 isshort-circuited.

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 21 of 51

20 Stability and mechanical hazards

20.1

Appliances, other than fixed appliances and hand-held appliances, intended to be used on a surfacesuch as the floor or a table shall have adequatestability.

Equipment found Stableat 10

P

During the test, temperature rises shall notexceed the values shown in table 9.

In compliance P

20.2

Moving parts of appliances shall, as far as iscompatible with the use and working of theappliance, be positioned or enclosed to provideadequate protection against personal injury innormal use.

P

Protective enclosures, guards and similar partsshall be non-detachable parts and shall haveadequate mechanical strength.

P

Not possible to touch dangerous moving partswith this test probe.Detachable accessories are removed and coversare opened except that for

-centrifugal juicers, the cover and the container forcollecting the residue are in position;

N/A

-graters and shredders, this is only applicable toaccessories that are removed while the applianceis in operation

N/A

20.101

Accessories for cream whippers, egg beaters andhand-held food mixers shall not have knife edges,unless a suitable guard prevents accidentalcontact with their rotating parts.

N/A

20.102Blades of hand-held blenders shall be completelyscreened from above and shall not be able totouch a flat surface while rotating.

N/A

20.103

Hand-held blenders shall incorporate a biased-offswitch, its actuating member being positioned in arecess or otherwise guarded to prevent accidentaloperation.

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 22 of 51

20.104It shall not be possible to inadvertently operate thecutting blades of blenders, other than hand-heldblenders, when they are accessible.

N/A

20.105Centrifugal juicers shall be constructed so thatcovers do not open due to vibration.

N/A

20.106

For appliances having a feed screw, the maximumcross-sectional dimension of the hopper,measured at least 100 mm from the upper edge ofthe feed screw, shall not exceed 45 mm. A feedpusher shall be provided and the feed screw ofthe appliance shall not be accessible to test probeB of IEC 61032 with the pusher in position

No feed screw used N/A

20.107

Slicing machines, other than fixed appliances andthose having a biased-off switch, shall incorporatemeans to hold the appliance in place and allow itto be released after use.

N/A

20.108

Slicing machines shall incorporate a guardsurrounding the circular knife, its open sectorbeing no larger than required for using theappliance

N/A

20.109Slicing machines shall be constructed so thataccidental operation of the appliance is prevented.

N/A

20.110

The cutting blades of bean slicers shall be at least30 mm from the plane of the inlet opening. Thelength of the major and minor axis of the inlet andoutlet openings shall not exceed 30 mm and 15mm. However, the dimensions of the outletopenings are not limited if a finger cannot bedrawn in and a piece of stiff paper is not cut wheninserted into the outlet opening.

N/A

20.111The rotating parts of blenders, graters andshredders shall be secured so that they are notliable to become loose during operation.

N/A

A feed pusher that fills the throat of the hoppershall be provided.

N/A

20.112The cutting blade of food processors shall stopwithin 1,5 s after the lid has been opened orremoved.

20.113

The lid interlock of food processors shall beconstructed so that accidental operation of theappliance is prevented.

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 23 of 51

20.114

Access to dangerous moving parts of foodprocessors shall be prevented for all combinationsof assembly of detachable parts that allow themotor to operate

N/A

20.115Knives shall incorporate a biased-off switch that isrecessed or guarded to prevent accidentaloperation.

N/A

20.116

Centrifugal juicers for fruit and vegetables shall beconstructed so that parts cannot becomedisengaged when the appliance is operated athigh speed.

N/A

20.117

Centrifugal juicers having a rotating sieve retainedby a rim of plastic material shall withstand thestresses resulting from parts rotating at highspeed.

N/A

20.118

The operation of cordless appliancesincorporating cutting blades that are accessible totest probe B of IEC 61032 shall require twoseparate movements unless the control device isnot directly accessible to the probe

N/A

20.119The bowl and cutting blades of food blenders andhand-held blenders shall have adequatemechanical strength.

N/A

21 Mechanical strength

21.1

Appliance shall have adequate mechanicalstrength and be constructed to withstand suchrough handling that may be expected in normaluse.

In compliance P

21.1This test is also carried out on detachable partsthat are necessary for protection againstmechanical hazards.

In compliance

21.2Accessible parts of solid insulation shall havesufficient strength to prevent penetration by sharpimplements.

In compliance P

22 Construction

22.1If the appliance is marked with the first numeral ofthe IP system, the relevant requirements of IEC60529 shall be fulfilled.

N/A

22.2

For stationary appliances, means shall beprovided to ensure all-pole disconnection from thesupply mains. Such means shall be one of thefollowing.

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 24 of 51

- a supply cord fitted with a plug; In compliance P

- a switch complying with 24.3 N/A

- a statement in the instructions that adisconnection incorporated in the fixed wiring is tobe provided;

N/A

- an appliance inlet. N/A

22.3Appliance provided with pins: no undue strain onsocket-outlets

N/A

Applied torque not exceeding 0.25 Nm N/A

Pull force of 50N to each pin after the appliancehas being placed in the heating cabinet

N/A

Each pin subjected to a torque of 0.4Nm; the pinsare not rotating unless rotating does not impaircompliance with the standard

N/A

22.4Appliance for heating liquids and appliancecausing undue vibration not provided with pins forinsertion into socket-outlets

N/A

22.5No risk of electric shock when touching the pins ofthe plug

In compliance P

22.6Electrical insulation not affected by condensingwater or leaking liquid

N/A

Electrical insulation of Class II appliances notaffected in case of a hose rupture or seal leak

N/A

22.7Adequate safeguards against the risk of excessivepressure in appliances provided with steam-producing devices

N/A

22.8

Electrical connections not subject to pulling duringcleaning of compartments to which access can begained without the aid of a tool, and that are likelyto be cleaned in normal use

In compliance P

22.9Insulation, internal wiring, windings, commutatorsand slip rings not exposed to oil, grease or similarsubstances

In compliance P

22.10Location or protection of reset buttons of non-self-resetting controls is so that accidental resetting isunlikely

In compliance P

22.11

Reliable fixing of non-detachable parts thatprovide the necessary degree of protectionagainst electric shock, moisture or contact withmoving parts

In compliance P

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 25 of 51

22.12Handles, knobs etc. Shall be fixed in a reliablemanner so that no loosening could result in ahazard

In Compliance P

Axial force 15 N applied to parts, the shape beingso that an axial pull is unlikely to be applied

P

Axial force 30 N applied to parts, the shape beingso that an axial pull is likely to be applied

P

22.13

Unlikely that handles, when gripped as in normaluse, make the operators hand touch parts havinga temperature rise exceeding the value specifiedfor handles which are held for short periods only

N/A

22.14No ragged or sharp edges creating a hazard for theuser in normal use, or during user maintenance

No ragged or sharp edgefound

P

No exposed pointed ends of self tapping screwsetc., liable to be touched by the user in normal useor during user maintenance

In compliance P

22.15Storage hooks and the like for flexible cordssmooth and well rounded

N/A

22.16

Automatic cord reels cause no undue abrasion ordamage to the sheath of the flexible cord, nobreakage of conductors strands, no undue wear ofcontacts

N/A

Cord reel tested with 6000 operations, as specified N/A

Electric strength test of 16.3, voltage of 1000 Vapplied

N/A

22.17 Spacers not removable from the outside by hand orby means of a screwdriver or a spanner

N/A

22.18 Current-carrying parts and other metal partsresistant to corrosion under normal conditions ofuse

N/A

22.19 Driving belts not used as electrical insulation N/A

22.20 Direct contact between live parts and thermalinsulation effectively prevented, unless materialused is non-corrosive, non-hygroscopic and non-combustible

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 26 of 51

22.21 Wood, cotton, silk, ordinary paper and fibrous orhygroscopic material not used as insulation, unlessimpregnated

N/A

22.22 Appliances not containing asbestos In compliance P

22.23 Oils containing polychlorinated biphenyl (PCB) notused

N/A

22.24 Bare heating elements adequately supported N/A

In case of rupture, the heating conductor is unlikely tocome in contact with accessible metal parts

N/A

22.25 Sagging heating conductors cannot come intocontact with accessible metal parts

N/A

22.26 The insulation between parts operating at safetyextra-low voltage and other live parts complies withthe requirements for double or reinforced insulation

N/A

22.27 Parts connected by protective impedance separatedby double or reinforced insulation

N/A

22.28 Metal parts of Class II appliances conductivelyconnected to gas pipes or in contact with water:separated from live parts by double or reinforcedinsulation

Class I appliance N/A

22.29 Class II appliances permanently connected to fixedwiring so constructed that the required degree ofaccess to live parts is maintained after installation

Class I appliance N/A

22.30 Parts serving as supplementary or reinforcedinsulation fixed so that they cannot be removedwithout being seriously damaged, or

N/A

so constructed that they cannot be replaced in anincorrect position, and so that if they are omitted, theappliance is rendered inoperable or manifestlyincomplete

N/A

22.31 Clearances and creepage distances oversupplementary and reinforced insulation shall not bereduced below values specified in clause 29 as aresult of wear.

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 27 of 51

22.32 Supplementary and reinforced insulation designed orprotected against deposition of dirt or dust

N/A

Supplementary insulation of natural or syntheticrubber resistant to ageing, or arranged anddimensioned so that creepage distances are notreduced below values specified in 29.2

N/A

Ceramic material not tightly sintered, similar materialor beads alone not used as supplementary orreinforced insulation

N/A

Oxygen bomb test at 70 C for 96 h and 16 h at roomtemperature

N/A

22.33 Conductive liquids that are or may becomeaccessible in normal use are not in direct contact withlive parts

N/A

Electrodes not used for heating liquids N/A

For class II constructions, conductive liquids that areor may become accessible in normal use, not indirect contact with basic or reinforced insulation

N/A

For class II constructions, conductive liquids whichare in contact with live parts, not in direct contact withreinforced insulation

N/A

22.34 Shafts of operating knobs, handles, levers etc. notlive, unless the shaft is not accessible when the partis removed

P

22.35 Handles, levers and knobs, held or actuated innormal use, not becoming live in the event of failureof basic insulation

P

22.36 Handles continuously held in the hand in normal useare so constructed that when gripped as in normaluse, the operators hand is not likely to touch metalparts, unless they are separated from live parts bydouble or reinforced insulation

N/A

22.37 Capacitors in Class II appliances not connected toaccessible metal parts, unless complying with 22.42

Class I appliance N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 28 of 51

Metal casings of capacitors in Class II appliancesseparated from accessible metal parts bysupplementary insulation, unless complying with22.42

Class I appliance N/A

22.38 Capacitors not connected between the contacts of athermal cut-out

N/A

22.39 Lamp holders used only for the connection of lamps N/A

22.40 Motor-operated appliances and combined appliancesintended to be moved while in operation, or havingaccessible moving parts, fitted with a switch to controlthe motor.

Not a portableequipment

N/A

-Any switch controlling the motor shall also disconnectelectronic circuits, the malfunction of which wouldimpair compliance with this standard.

No electronic circuitused

N/A

22.41 No components, other than lamps, containingmercury

N/A

22.42 Protective impedance consisting of at least twoseparate components. Values specified in 8.1.4 notexceeded if any one of the components are short-circuited or open-circuited

N/A

22.43 Appliances adjustable for different voltages,accidental changing of the setting of the voltageunlikely to occur

Appliance operatedthrough Single supply

N/A

22.44 Appliances are not allowed to have an enclosure thatis shaped and decorated so that the appliance islikely to be treated as a toy by children

P

22.45 When air is used as reinforced insulation, clearancesnot reduced below the values specified in 29.1.4 dueto deformation as a result of an external force appliedto the enclosure

N/A

22.46 Software used in protective electronic circuit shall besoftware class B or software class C

N/A

22.47 Appliances intended to be connected to the watermains shall withstand the water pressure expected innormal use.

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 29 of 51

22.48 Appliance intended to be connected to the watermains shall be constructed to prevent backiphonageof non-potable water into the water mains

N/A

22.49 For remote operation, the duration of operation shallbe set before the appliance can be started unless theappliance switches off automatically at the end of acycle or it can operate continuously without givingrise to a hazard

N/A

22.50 Controls incorporated in the appliance, if any, shalltake priority over controls actuated by remoteoperation.

N/A

22.51 A control on the appliance shall be manuallyadjusted, to the setting for remote operation beforethe appliance can be operated in this mode.

N/A

22.52 Socket-outlets on appliances accessible to the usershall be accordance with the socket-outlet systemused in the country in which the appliance is sold.

N/A

22.101Appliances shall be constructed so that lubricants areprevented from polluting food compartments.

No lubricants used N/A

22.102Appliances shall be constructed so that food orliquids are prevented from penetrating into placesthat could cause electrical or mechanical faults.

In Compliance P

22.103The appliance coupler of cordless blenders shall beconstructed to withstand the stresses occurringduring normal use.

N/A

23 Internal Wiring

23.1 Wireways smooth and free from sharp edges Smooth wirewayspresent

P

Wires protected against contact with burrs, coolingfins etc.

In compliance P

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 30 of 51

Wire holes in metal well rounded or provided withbushings

N/A

Wiring effectively prevented from coming into contactwith moving parts

P

23.2 Beads etc. on live wires cannot change their position,and are not resting on sharp edges or corners

N/A

Beads inside flexible metal conduits contained withinan insulating sleeve

N/A

23.3 Electrical connections and internal conductorsmovable relatively to each other not exposed toundue stress

N/A

Flexible metallic tubes not causing damage toinsulation of conductors

N/A

Open-coil springs not used N/A

Adequate insulating lining provided inside a coiledspring, the turns of which touch one another

N/A

No damage after 100 000 flexings for conductorsflexed during normal use and at rated

N/A

Electric strength test, 1000 V between live parts andaccessible metal parts

N/A

23.4 Bare internal wiring sufficiently rigid and fixed innormal use, clearances or creepage distancescannot be reduced below the values specified inClause 29

N/A

23.5 The insulation of internal wiring withstanding theelectrical stress likely to occur in normal use

N/A

No breakdown when a voltage of 2000 V is appliedfor 15 min between the conductor and metal foilwrapped around the insulation

N/A

23.6 Sleeving used as supplementary insulation oninternal wiring retained in position by positive means

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 31 of 51

23.7 The colour combination green/yellow used only forearthing conductors

P

23.8 Aluminium wires not used for internal wiring In compliance P

23.9 No lead-tin soldering of stranded conductors wherethey are subject to contact pressure, unless

N/A

clamping means so constructed that there is no riskof bad contact due to cold flow of the solder

N/A

23.10 The insulation and sheath of internal wiring,incorporated in external hoses for the connection ofan appliance to the water mains, shall be at leastequivalent to that of light pvc sheathed flexible cord.

N/A

24 Components

24.1 Components comply with safety requirements inrelevant IEC standards

24.1.1 Capacitors likely to be permanently subjected to thesupply voltage and used for radio interferencesuppression or for voltage dividing, complying withIEC 60384-14, or

N/A

24.1.2 Safety isolating transformers complying with IEC61558-2-6, or

N/A

24.1.3Switches incorporated in the following appliances aretested for 3 000 cycles of operation:

N/A

bean slicers;liquid blenders;cheese graters;graters;ice-cream machines for use in refrigerators andfreezers;sieving machines;shredders.

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 32 of 51

24.1.4 Automatic controls complying withIEC 60730-1 with relevant part 2.The number of cycles of operationbeing:

N/A

- thermostats: 10 000 N/A

- temperature limiters: 1 000 N/A

- self-resetting thermal cut-outs: 300 N/A

- non-self-resetting thermal cut-outs 30 N/A

- timers: 3 000 N/A

- energy regulators: 10 000 P

24.1.5 Appliance couplers complying with IEC 60320-1 N/A

However, appliances classified higher than IPX0, theappliance couplers complying with IEC 60320-2-3

N/A

24.1.6 Small lamp holders similar to E10 lampholderscomplying with IEC 60238, the requirements for E10lampholders being applicable

N/A

24.1.7 If the remote operation of the appliance is via atelecommunication network, the relevant standard fortelecommunication interface circuitry in the applianceis IEC 62151

N/A

24.1.8 The relevant standard for thermal links is IEC 60691.Thermal links that do not comply with IEC 60691 areconsidered to be an intentionally weak part for thepurposes of clause 19.

N/A

24.1.9 Relays other than motor starting relays, are tested aspart of the appliances

P

24.2 Appliances shall not be fitted with

switches or automatic controls in flexible cords; P

devices that cause the protective device in thefixed wiring to operate in the event of a fault in theappliance

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 33 of 51

thermal cut-outs that can be reset by a solderingoperation, unless the solder has a melting point of atleast 230 °C

N/A

24.3 Switches intended for all-pole disconnection ofstationary appliances are directly connected to thesupply terminals and having a contact separation inall poles, providing full disconnection underovervoltage category III conditions

N/A

24.4 Plugs and socket-outlets for extra-low voltage circuitsand heating elements, not interchangeable with plugsand socket-outlets listed in IEC 60083 or IEC 60906-1 or with connectors and appliance inlets complyingwith the standard sheets of IEC 60320-1

No heating element

foundN/A

24.5 Capacitors in auxiliary windings of motors markedwith their rated voltage and capacitance and usedaccordingly

N/A

Capacitors in appliances for which 30.2.3 isapplicable and that are permanently connected inseries with a motor winding, are of class P1 or P2 ofIEC 60252

N/A

Voltage across capacitors in series with a motorwinding does not exceed 1,1 times rated voltage,when the appliance is supplied at 1,1 times ratedvoltage under minimum load

N/A

24.6 Working voltage of motors connected to the supplymains and having basic insulation that is inadequatefor the rated voltage of the appliance, not exceeding42V.

N/A

24.7 Hose-sets for the connection of appliances to thewater mains, shall comply with IEC 61770.

N/A

25 Supply Connection And External Flexible Cords

25.1 Appliance not intended for permanent connection tofixed wiring, means for connection to the supply:

- supply cord fitted with a plug P

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 34 of 51

- an appliance inlet having at least the same degreeof protection against moisture as required for theappliance

N/A

- pins for insertion into socket-outlets P

-Ice-cream machines for use in refrigerators andfreezers and hand-held appliances shall notincorporate an appliance inlet.

N/A

25.2 Appliance not provided with more than one means ofconnection to the supply mains

Single connection

present for supply mainsP

Stationary appliance for multiple supply may beprovided with more than one means of connection,provided electric strength test of 1250 V for 1 minbetween each means of connection causes nobreakdown

N/A

25.3 Connection of supply conductors for applianceintended to be permanently connected to fixed wiringpossible after the appliance has been fixed to itssupport

N/A

Appliance provided with a set of terminals for theconnection of cables or fixed wiring, cross-sectionalareas specified in 26.6

N/A

Appliance provided with a set of terminals allowingthe connection of a flexible cord

N/A

Appliance provided with a set of supply leadsaccommodated in a suitable compartment

N/A

Appliance provided with a set of terminals and cableentries, conduit entries, knock-outs or glands,allowing connection of appropriate type of cable orconduit

Cable entries provided

P

25.4 Cable and conduit entries, rated current of appliancenot exceeding 16 A, dimensions according to table 10

No conduit presentN/A

Introduction of conduit or cable does not reduceclearances or creepage distances below valuesspecified in 29

No conduit presentN/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 35 of 51

25.5 Method for assemble supply cord with the appliance:

- type X attachment Type Y attachment

providedN/A

- type Y attachment P

- type Z attachment is allowed for portable fans(IEC 60335-2-80)

Type Y attachment

providedN/A

Type X attachment, other than those with a speciallyprepared cord, not used for flat twin tinsel cords

N/A

25.5 Type Z attachment is allowed for

can openers;coffee mills and grain grinders having a mass notexceeding 1,5 kg;cream whippers;egg beaters;ice-cream machines including those for use inrefrigerators and freezers;knife sharpeners.

N/A

Type X attachments, other than those with aspecially prepared cord, shall not be used forice-cream machines for use in refrigerators andfreezers.

N/A

25.6 Plugs shall not be fitted with more than one flexiblecord.

In complianceP

25.7 Supply cords shall be one of the following types

- rubber sheathed (code 60245 IEC 53) N/A

- Polychloroprene sheathed (code designation 60245IEC 57)

N/A

- Cross linked polyvinyl chloride sheathed. Codedesignation 60245 IEC 87)

N/A

- Polyvinyl chloride sheathed In Compliance P

- heat resistant polyvinyl chloride sheathed. N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 36 of 51

-Polyvinyl chloride sheathed supply cords of ice-cream machines for use in refrigerators andfreezers shall be resistant to low temperatures.

N/A

25.8 Nominal cross-sectional area of supply cordsaccording to table 11; rated current (A); cross-sectional area (mm²)

25.9 Supply cord not in contact with sharp points or edges In compliance P

Green/yellow core for earthing purposes in Class Iappliance

ProvidedP

25.11 Conductors of supply cords not consolidated by lead-tin soldering where they are subject to contactpressure, unless

N/A

clamping means so constructed that there is no riskof bad contacts due to cold flow of the solder

N/A

25.12 the insulation of the supply cord shall not bedamaged when Moulding the cord to part of theenclosure.

No damage foundP

25.13 Inlet opening so shaped as to prevent damage to thesupply cord

No damage foundP

25.14 Appliances provided with a supply cord and that aremoved while in operation shall be constructed so thatthe supply cord is adequately protected againstexcessive flexing where it enters the appliance.

Stationary appliance

N/A

The test does not result in:

- breakage of more than 10% of the strands of anyconductor

N/A

- separation of the conductor from its terminal N/A

- loosening of any cord guard N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 37 of 51

- damage, within the meaning of the standard, to thecord or the cord guard

N/A

- broken strands piercing the insulation and becomingaccessible

N/A

25.14Hand-held blenders and hand-held mixers are alsosubjected to the following test while mounted on anapparatus similar to that of Figure 8.

Stationary applianceN/A

25.15 Appliances provided with a supply cord, andappliances intended to be permanently connected tofixed wiring by a flexible cord, shall have a cordanchorage.

In compliance

P

The cord anchorage shall relieve conductors fromstrain, including twisting, at the terminals and protectthe insulation of the conductors from abrasion.

In complianceP

It shall not be possible to push the cord into theappliance to such an extent that the cord or internalparts of the appliance could be damaged.

In complianceP

25.16 Cord anchorages for type X attachments constructedand located so that:

Y type attachment

providedN/A

- replacement of the cord is easily possible N/A

- it is clear how the relief from strain and theprevention of twisting are obtained

N/A

- they are suitable for different types of cord N/A

- cord cannot touch the clamping screws of cordanchorage if these screws are accessible, unlessseparated from accessible metal parts bysupplementary insulation

N/A

- the cord is not clamped by a metal screw whichbears directly on the cord

N/A

- at least one part of the cord anchorage securelyfixed to the appliance, unless part of a speciallyprepared cord

N/A

- screws which have to be operated when replacingthe cord do not fix any other component, if applicable

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 38 of 51

- if labyrinths can be bypassed the test of 25.15 isnevertheless withstood

N/A

- for Class 0, 0I and I appliances: they are ofinsulating material or are provided with an insulatinglining, unless a failure of the insulation of the corddoes not make accessible metal parts live

N/A

- for Class II appliances: they are of insulatingmaterial, or if of metal, they are insulated fromaccessible metal parts by supplementary insulation

N/A

25.17 Adequate cord anchorages for type Y and Zattachment

Compliance has beenchecked according to Cl.25.15

P

25.18 Cord anchorages only accessible with the aid of atool, or so constructed that the cord can only be fittedwith the aid of a tool

In complianceP

25.19 Type X attachment, glands not used as cordanchorage in portable appliances

Type Y attachment

present N/A

Tying the cord into a knot or tying the cord with stringnot used

N/A

25.20 Conductors of the supply cord for type Y and Zattachment adequately additionally insulated

In complianceP

25.21 Space for supply cord for type X attachment or forconnection of fixed wiring constructed to permitchecking of conductors with respect to correctpositioning and connection before fitting any cover,no risk of damage to the conductors when fitting thecover, no contact with accessible metal parts if aconductor becomes loose, etc.

Type Y attachment

N/A

For portable appliances, the uninsulated end of aconductor prevented from any contact withaccessible metal parts, unless the end of the cord issuch that the conductors are unlikely to slip free

Not a portable appliance

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 39 of 51

25.22 Appliance inlet:

- live parts not accessible during insertion or removal N/A

- connector can be inserted without difficulty N/A

- the appliance is not supported by the connector N/A

- is not for cold conditions if temp. rise of externalmetal parts exceeds 75 K, unless the supply cord isnot likely to touch such metal parts

N/A

25.22Appliance inlets shall be located so that pollution byfood or liquid is unlikely to occur during normal use

N/A

25.23 Interconnection cords comply with the requirementsfor the supply cord, except as specified

N/A

If necessary, electric strength test of 16.3 N/A

25.24 Interconnection cords not detachable without the aidof a tool if compliance with the standard is impairedwhen they are disconnected

N/A

25.25 Dimensions of pins and engagement face inaccordance with the relevant plug in IEC 60083

N/A

26 Terminals for external conductors

26.1 Appliances provided with terminals or equallyeffective devices for connection of externalconductors

ProvidedP

Terminals only accessible after removal of a non-detachable cover

In complianceP

26.2 Appliances with type X attachment and appliances forconnection to fixed wiring provided with terminals inwhich connections are made by means of screws,nuts or similar devices, unless the connections aresoldered

Y type attachment

presentN/A

Screws and nuts serve only to clamp supplyconductors, except

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 40 of 51

internal conductors, if so arranged that they areunlikely to be displaced when fitting the supplyconductors

N/A

If soldered connections used, the conductor sopositioned or fixed that reliance is not placed onsoldering alone

N/A

Soldering alone used, barriers provided, clearancesand creepage distances satisfactory if the conductorbecomes free at the soldered joint

N/A

26.3 Terminals for type X attachment and for connectionto fixed wiring so constructed that the conductor isclamped between metal surfaces with sufficientcontact pressure and without damaging theconductor

Y type attachment

presentN/A

Terminals for type X attachment and those forconnection to fixed wiring so fixed that whentightening or loosening the clamping means:

N/A

- the terminal does not loosen N/A

- internal wiring is not subjected to stress N/A

- clearances and creepage distances are not reducedbelow the values in 29

N/A

Compliance checked by inspection and by the test ofsubclause 8.6 of IEC 60999-1, the torque appliedbeing equal to two-thirds of the torque specified.Nominal diameter of thread (mm); screw category;torque (Nm)

N/A

26.4 Terminals for type X attachment, except those with aspecially prepared cord, and those for connection tofixed wiring, no special preparation of conductorsrequired, and so constructed or placed thatconductors prevented from slipping out

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 41 of 51

26.5 Terminals for type X attachment so located orshielded that if a wire of a stranded conductorescapes, no risk of accidental connection to otherparts that result in a hazard

N/A

No contact between live parts and accessible metalparts and, for class II constructions, between liveparts and metal parts separated from accessiblemetal parts by supplementary insulation only

N/A

26.6 Terminals for type X attachment and for connectionto fixed wiring suitable for connection of conductorswith required cross-sectional area according totable 13; rated current (A); nominal cross-sectionalarea (mm²) .............................................................:

N/A

Terminals only suitable for a specially prepared cord N/A

26.7 Terminals for type X attachment accessible afterremoval of a cover or part of the enclosure

Y type attachment

presentN/A

26.8 Terminals for the connection to fixed wiring, includingthe earthing terminal, located close to each other

In complianceP

26.9 Terminals of the pillar type constructed and locatedas specified

N/A

26.10 Terminals with screw clamping and screwlessterminals not used for flat twin tinsel cords, unlessconductors ends fitted with a device suitable forscrew terminals

N/A

Pull test of 5 N to the connection N/A

26.11 For type Y and Z attachment: soldered, welded,crimped and similar connections may be used

In complianceP

For Class II appliances: the conductor so positionedor fixed that reliance is not placed on soldering,welding or crimping alone

No soldered connectionused N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 42 of 51

For Class II appliances: soldering, welding orcrimping alone used, barriers provided, clearancesand creepage distances satisfactory if the conductorbecomes free

N/A

27 Provision For Earthing

27.1 Accessible metal parts of Class 0I and I appliances,permanently and reliably connected to an earthingterminal or contact of the appliance inlet

In ComplianceP

Earthing terminals not connected to neutral terminal In compliance P

Class 0, II and III appliance have no provision forearthing

N/A

Safety extra-low voltage circuits not earthed, unlessprotective extra-low voltage circuits

N/A

27.2 Clamping means adequately secured againstaccidental loosening

In ComplianceP

Terminals used for the connection of externalequipotential bonding conductors allow connection ofconductors of 2.5 to 6 mm², and do not provideearthing continuity between different parts of theappliance

N/A

Conductors cannot be loosened without the aid of atool

P

27.3 For appliances with supply cord, current-carryingconductors become taut before earthing conductor, ifthe cord slips out of the cord anchorage

p

27.4 All parts of the earthing terminal intended for theconnection of external conductors shall be suchthat there is not risk of corrosion resulting fromcontact between these parts and the copper ofthe earthing conductor or

P

Parts providing earthing continuity, other thanparts of metal frame or enclosure shall be ofmetal having adequate resistance to corrosion

P

If the body of the earthing terminal is a part offrame or enclosure of aluminum or its alloys

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 43 of 51

27.5 The connection between earthing terminal andearthed metal parts shall have low resistance

The resistance calculated shall not exceed 0.1 Ω at 25 Amp.

(Refer Table C)

P

27.6 The printed conductors of printed circuit boards notused to provide earthing continuity in hand heldappliances

N/A

They may be used in other appliances if: N/A

- at least two tracks are used with independentsoldering points and the appliance complies withrequirements of 27.5 for each circuit

N/A

28 Screws and connections

28.1 Fixings, electrical connections and connectionsproviding earthing continuity withstand mechanicalstresses

N/A

Screws not of soft metal liable to creep, such as zincor aluminium

P

Diameter of screws of insulating material min. 3 mm N/A

Screws of insulating material not used for anyelectrical connection or connections providingearthing continuity

No screw of insulatingmaterial has been used N/A

Screws used for electrical connections orconnections providing earthing continuity screw intometal

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 44 of 51

Screws not of insulating material if their replacementby a metal screw can impair supplementary orreinforced insulation

N/A

Type X attachment, screws to be removed forreplacement of supply cord or for user maintenance,not of insulating material if their replacement by ametal screw can impair basic insulation

N/A

28.2 Electrical connections and connections providingearthing continuity constructed so that contactpressure not transmitted through insulating materialliable to shrink or distort, unless shrinkage ordistortion compensated

N/A

This requirement does not apply to electricalconnections in circuits carrying a current notexceeding 0.5A

N/A

28.3 Space-threaded (sheet metal) screws only used forelectrical connections if they clamp the parts together

N/A

Thread-cutting (self-tapping) screws only used forelectrical connections if they generate a full formstandard machine screw thread

In complianceP

Thread-cutting and space-threaded screws may beused in connections providing earthing continuity,provided unnecessary to disturb the connection andat least two screws are used for each connection

N/A

28.4 Screws and nuts that make mechanical connectionsecured against loosening if they also make electricalconnections or connections providing earthingcontinuity

N/A

Rivets for electrical connections or connectionsproviding earthing continuity secured againstloosening if subjected to torsion

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 45 of 51

29 Clearances, creepage distances and solidinsulation

Clearances, creepage distances and solid insulationwithstand electrical stress

In compliance

(Refer Table D)P

29.1 Clearances not less than the values specified in table16, taking into account the rated impulse voltage forthe overvoltage categories of table 15

In ComplianceP

for basic insulation and functional insulation, theycomply with the impulse voltage test of Clause 14

However, if the construction is such that thedistances could be affected by wear, by distortion,by movement of the parts or during assembly, theclearances for rated impulse voltages of 1 500 Vand above are increased by 0,5 mm and theImpulse voltage test is not applicable

N/A

29.1.1 The clearances of basic insulation shall be sufficientto withstand the overvoltages likely to occur duringuse, taking into account the rated impulse voltage

The clearance at the terminals of tubular sheathedheating elements may be reduced to 1,0 mm if themicroenvironment is pollution degree 1.

N/A

Lacquered conductors of windings assumed to bebare conductors, but the clearances specified in table16 are reduced by 0.5mm for rated impulse voltagesof at least 1500V

29.1.2 Clearances of supplementary insulation not less thanthose specified for basic insulation in table 16

N/A

29.1.3 Clearances of reinforced insulation not less thanthose specified for basic insulation in table 16, butusing the next higher step for rated impulse voltage

N/A

29.1.4 For functional insulation, the values of table 16 areapplicable, unless

the appliance complies with clause 19 with thefunctional insulation short-circuited

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 46 of 51

Clearances at crossover points of lacqueredconductors not measured

N/A

Clearance between surfaces of PTC heatingelements may be reduced to 1mm

N/A

29.1.5 Appliances having higher working voltage than ratedvoltage, the voltage used for determining clearancesfrom table 16 is the sum of the rated impulse voltageand the difference between the peak value of theworking voltage and the peak value of the ratedvoltage

N/A

If the secondary winding of a step-down transformeris earthed, or if there is an earthed screen betweenthe primary and secondary windings, clearances ofbasic insulation on the secondary side not less thanthose specified in table 16.

N/A

29.2 Appliances shall be constructed so that Creepagedistances are not less than those appropriate for theworking voltage, taking into account the materialgroup and the pollution degree

Pollution degree 2 applies, unless N/A

precautions taken to protect the insulation; pollutiondegree 1

P

insulation subjected to conductive pollution; pollutiondegree 3

N/A

29.2.1 Creepage distances of basic insulation shall not beless than specified in table 17

In ComplianceP

Except for pollution degree 1, creepage distanceshall not be less than the minimum specified for theclearance in table 16.

N/A

29.2.2 Creepage distances of supplementary insulation shallbe at least as specified for basic insulation in table 17

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 47 of 51

29.2.3 Creepage distances of reinforced insulation shall beat least double as specified for basic insulation intable 17

N/A

29.2.4 Creepage distances of functional insulation shall notbe less than specified in table 18

P

29.2

The microenvironment is pollution degree 3 unlessthe insulation is enclosed or located sothat it is unlikely to be exposed to pollution duringnormal use of the appliance.

N/A

29.3 Supplementary insulation and reinforcedinsulation shall have adequate thickness or havea sufficient number of layer, to withstand theelectrical stress that can be expected during theuse of the appliance

N/A

29.3.1 The thickness of the insulation shall be at least N/A

- 1 mm for supplementary insulation N/A

and 2mm for reinforced insulation N/A

29.3.2 Each layer of material shall withstand electricstrength of 16.3 for supplementary insulation.

N/A

30 Resistance to heat and fire

30.1 External parts of non-metallic material, parts ofinsulating material supporting live parts and partsof thermoplastic material providing supplementary orreinforced insulation shall be sufficiently resistant toheat.

Satisfactory result found,

ball pressure test has been

conducted according to

IEC 60695-10-2

P

30.2 Relevant parts of non-metallic material adequatelyresistant to ignition and spread of fire

N/A

30.2.1 Glow-wire test of IEC 60695-2-11 at 550 C, unless N/A

the material is classified at least HB40 according toIEC 60695-11-10

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 48 of 51

Parts for which the glow-wire test cannot be carriedout meet the requirements in ISO9772 for categoryHBF material

N/A

30.2.2 For appliances that are operated while attended,parts of non-metallic material supporting current-carrying connections and parts of non-metallicmaterial within a distance of 3 mm of suchconnections are subjected to the glow-wire test ofIEC 60695-2-11.

Non-metallic part notcarrying currentconnection

N/A

750 °C, for connections that carry a currentexceeding 0,5 A during normal operation,

N/A

– 650 °C, for other connections. N/A

30.2.3 Appliances operated while unattended, tested asspecified in 30.2.3.1 and 30.2.3.2

N/A

30.2.3.1 Parts of insulating material supporting connectionscarrying a current exceeding 0.2A during normaloperation, and

N/A

parts of insulating material within a distance of 3mm, N/A

having a glow-wire flammability index of at least850C according to IEC 60695-2-12

N/A

30.2.3.2 Parts of insulating material supporting current-carrying connections, and

N/A

parts of insulating material within a distance of 3mm, N/A

subjected to glow-wire test of IEC 60695-2-11 N/A

Test not carried out on material having a glow-wireignition temperature according to IEC 60695-2-13 asspecified

N/A

Glow-wire test of IEC 60695-2-11, the temperaturebeing:

N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 49 of 51

-750C, for connections carrying a current exceeding0,2A during normal operation

N/A

-650C, for other connections N/A

Parts that during the test produce a flame persistinglonger than 2 s, tested as specified

N/A

If a flame persists longer than 2 s during the test,parts above the connection, as specified, subjectedto the needle-flame test of annex E, unless

N/A

The material classified as V-0 or V-1 according toIEC 60695-11-10 are not subjected to needleflame test.

N/A

30.2.4 Base material of printed circuit boards subjected toneedle-flame test of annex E

N/A

Test not applicable to conditions as specified

31 Resistance to rusting

Relevant ferrous parts adequately protected againstrusting

N/A

32 Radiation, toxicity and similar hazards

Appliance does not emit harmful radiation N/A

Appliance does not present a toxic or similar hazard N/A

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 50 of 51

Table A:

Cl. 10.1 TABLE: Power input deviation P

Input deviation of/at: P rated (W) P measured(W)

Allowed Deviation Remark

MG 828 650 W 560 +15% Within limit

Table B:

Table : B1

Cl. 11.8 TABLE: Heating test, thermocouples P

Test voltages (V)....................................................: At 0.94 * 230 = 216.2 V

Ambient (C) ..........................................................: 26OC

Thermocouple locations Temp. Measured Maximum Rise Temp.

a) power Cord 33oC 7

oC

b) Metallic Jar 43oC 17

oC

c) Plastic Enclosure 31o C 5 oC

Table : B2

Cl. 11.8 TABLE: Heating test, thermocouples P

Test voltages (V)....................................................: At 1.06 * 230 = 243.8

Ambient (C)..........................................................: 25OC

Thermocouple locations Temp. Measured Maximum Rise Temp.

a) Power Cord 33oC 8

oC

b) Metallic Jar 45oC 20

oC

c) Plastic Enclosure 34oC 9

oC

INSTITUTE OF TESTING AND CERTIFICATION(INDIA) PVT. LTD.

IEC 60335-1 & IEC 60335-2-14

60335-1 60335-2-14 Requirement – Test Results – Remarks Verdict

Report No.-ITC/TEST/NN/18 Page 51 of 51

Table C

Clause . No. Test Conducted Test Conditions Test requirement Results

Cl. 13.2

Leakage Current Test

Motor operated appliance:1.06 times of rated voltage:Between : Each pole of thesupply source and theaccessible metal part of themixer grinder

Shall not exceed3.5mA

Pass(Imea <1µA)

Cl. 13.3High Voltage Test

Test voltage: : 1000 VTest Duration: 1 min.Test Part: Between live partand metal part of the mixergrinder

Shall withstandwithout breakdown

PassNo flashover occur(Imea00.52mA)

Cl. 14 Impulse Test(Transientovervoltages

Transient Overvoltage: 2920VThe impulse test voltage isapplied three times for eachpolarity with intervals of atleast 1 s.

There shall be noflashover.

Pass, No flashoveroccur.

Cl. 27.5Earth ContactResistance Test

Test Current: 25ATest Part : Betweenprotective earth terminals andbody that is part of theprotective bonding circuit.

Calculated EarthContact Resistancefrom current & dropin voltage shall notexceed 0.1 Ω)

Pass(Rmea55.7 mΩ)

Table D

Cl. 29

Minimum distance(mm)

Measured distance(mm)

Verdict

Clearances

- Basic insulation(at Rated Impulse Voltage 2500)

1.5 >1.5mm P

Creepage distances

- Basic Insulation (at Working voltage250V for pollution Degree 1)

0.56 >0.56mm P