15
Instruction Manual Malanda/Avalon 1200x900(8mm) 1 With Decina's Exclusive EZI Clean Coating

Instruction Manual Malanda/Avalon

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Instruction Manual Malanda/Avalon

Instruction ManualMalanda/Avalon

1200x900(8mm)

1

With Decina's Exclusive EZI Clean Coating

Page 2: Instruction Manual Malanda/Avalon

- The use of harsh or abrasive cleaners will cause deterioration of the EZI�Clean

coating. If water alone is not enough to clean the glass, Decina recommends the

use of mild detergent solutions only.

Utility Knife

- Please read this entire instruction book before commencing installation.

- A licenced tradesman must be used for the installation.- Ensure there is a gasket between all glass and metal components.- Leave the plastic protectors on the glass corners until the last possible momentand handle with care.- Instructions to install the shower tray are included with the shower tray.- In cold climates, warming the gaskets and seals with hot water or a hairdryer willassist installation.

- On symmetrical pieces of glass, the EZI�Clean coating is only on one face. This

face will have a sticker on it to identify it. This side must be installed on the wet

side of the shower.

Cutting Pliers

6mm (1/4") and3mm (1/8") Drill Bits

* Use the correct type of drill bit for the material being drilled, with 6mm required for anchor fixing and 3mm used forscrewing directly into the wall studs.

Safety Goggles Gloves

**

As with all toughened glass, take care while handling and wear safety goggles and gloves for personal protection.

Silicone Sealant Drill Level Rubber Mallet

Pencil Phillips Screwdriver Tape Measure

2

Important Pre-Installation Information

Maintenance

Tools Required

Page 3: Instruction Manual Malanda/Avalon

3

a4. Roller wrench tool x2pcs

Screen

9 10 12

17

18

19

20

s4

1

1

2

3

4

5

6

7

22

23

24

1311

14

15

16

8

s5

s6

s7

s8

s3s2

s9

s12

s1

s11

s10

Return Panel

s13

Parts List

1. Channel Cap2. Wall Channel3. Wall Channel Gasket4. Front Panel Glass5. Wall Anchor6. Hinge Side Door Gasket(1918mm)

7. Hinge Side Door Gasket(1912mm)

8. Phillips Head Screw ST4x409. Rail10. Door Glass11. Handle12. Wall bracket base

13. Magnet profile14. Magnetic Door Seal(1988mm)15. Magnetic Door Seal(2000mm)16. Cap L/R17. Countersunk Philip head screw18. guideL/R

20. Long Drip Strip21. Threshold22. Squeeze gasket tool23. Glass Wedge spacer

1 pcs1 pcs1 pcs1 pcs11 pcs1 pcs1 pcs10 pcs1 pcs1 pcs1 pcs1 pcs

1 pcs1 pcs1 pcs1 pcs1 pcs1 pcs

1 pcs1 pcs1 pcs2 pcs

24. Allan key kit2.5mm/3mm 1 pcs

s1. Magnet strip

s2. Chrome kit for bar

s3. Side Panel Glass

s4. Channel Cap

s5. Wall Channel

s6. Wall Channel Gasket

s7. Wall Anchor

s8. Phillips Head Screw ST4x40

s9. Screw cap

s10. Countersunk Philip head screw

s11. 90°Bottom Clamp L/R

s12. Gasket

1 pcs

1 pcs

1 pcs

1 pcs

1 pcs

1 pcs

5 pcs

4 pcs

2 pcs

1 pcs

1 pcs

1 pcs

s13. Glass Wedge spacer

21

19. Gasket 1 pcs

2 pcs

Malanda: Round Roller Avalon: Square Roller

a1. Rollerx2pcs

a3. Roller bumperx1pcs

a2. Fixing plate x2pcs b1. Roller x2pcs

b2. Fixing plate x2pcs

b5. Roller wrench tool x2pcs

b3. Fixing plate cap x2pcs

b4. Roller bumperx1pcs

Page 4: Instruction Manual Malanda/Avalon

4

When commencing step 1 on the following page, please refer to this drawing and the tabulated

dimensions for your size of system to assist in the correct location of the wall channels.

SHOWERWALL

FRONT OFSHOWER

SHOWERDOOR

- Locate the size of your shower screen in column 1 and use the value for X and Y on the same line

to find the distance from the shower wall to the outside edge of the wall channels. If a shower base is

fitted, do not measure from the edge of the shower base to determine the position of the wall channel.

- If your wall and shower base are not at right angles the glass will not push fully into the wall channel

at the top or bottom. This misalignment is acceptable if not exceeding 15mm, however the overall

shower size will then increase by the amount of this misalignment.

- If the screen footprint does not turn out square while the aluminium braces are being installed (step

3), the glass can be pulled out from the full depth of the channel by up to 15mm to assist in squaring.

Size

X

(Wall to outside of wall channel)

Screen X

(mm)

1200 1154-1178

OPTIONALSHOWERBASE

Determining Wall Channel Location

Page 5: Instruction Manual Malanda/Avalon

1

¼" (Ø6mm)

1B

1C

1D

1E

1A

5

2

2A 2B

2C 2D 2E

2F 2G 2H

OR

2

2

4

5

8

9

9

12

23

24

a2 b2

b3

Page 6: Instruction Manual Malanda/Avalon

6

Inside door

±13mm+0 mm

-12mm

3E

3

4

3B

3C

3D

3A

4A LH

RH

a

4C

b

4D

4E 4F 4G

4H 4I 4J 4K

4B

b

3

3

16

17

1819

2021

22

Page 7: Instruction Manual Malanda/Avalon

7

5

6

Inside door5B

Inside door5C

5E

Inside door

Inside door

A22

5A OR

OR

OR

Inside door

6A

6B

Inside door

6C

OR

10

14

a1

a4

b1

b5

Page 8: Instruction Manual Malanda/Avalon

7

8

8

7A

OR

7B

7C

7D

7E

¼" (Ø6mm)

4X

Inside door

Inside door

Inside door

8A 8B

8C 8D

8E 8F

8G 8H6

7

11

13

15

a3

b3

b4

Inside door

b2

R11 Fixing plate:

Page 9: Instruction Manual Malanda/Avalon

9

24 hSILICONE

Silicone inside and outside ofthe shower (silicone notsupplied).

9

1

Page 10: Instruction Manual Malanda/Avalon

When commencing step 1 on the following page, please refer to this drawing and the tabulated

dimensions for your size of system to assist in the correct location of the wall channels.

SHOWER

WALL

FRONT OF

SHOWER

SHOWER

DOOR

- Locate the size of your shower screen in column 1 and use the value for X and Y on the same line

to find the distance from the shower wall to the outside edge of the wall channels. If a shower base is

fitted, do not measure from the edge of the shower base to determine the position of the wall channel.

- If your wall and shower base are not at right angles the glass will not push fully into the wall channel

at the top or bottom. This misalignment is acceptable if not exceeding 15mm, however the overall

shower size will then increase by the amount of this misalignment.

- If the screen footprint does not turn out square while the aluminium braces are being installed (step

3), the glass can be pulled out from the full depth of the channel by up to 15mm to assist in squaring.

X

(Wall to outside of wall channel)

OPTIONAL

SHOWER

BASE

Determining Wall Channel Location

10

SIDE OF

SHOWER

Y

(Wall

too

uts

ide

of

wa

llch

annel)

Size

Screen X

(mm)

1200 x 900

Y

(mm)

854-8781154-1178

Page 11: Instruction Manual Malanda/Avalon

1

2

¼" (Ø6mm)

1B

1C

1D

1E

11

±13mm

+12mm-0mm

OR

2A 2B

2C 2D

2E 2F

s2

s3

s3

s52

s75

s88

s13

Page 12: Instruction Manual Malanda/Avalon

3

4

12

Inside door

±13mm

LHRH

44

RH LH

b

a

b

4B

4D

4F 4G

4H 4I 4J 4K

3A 3B

3C

3D

a

4A

4C

4E

s63

s9

s10

s11

s12

Page 13: Instruction Manual Malanda/Avalon

13

5

6

Inside door

6A

6B

Inside door

6C

OR

Inside doorb3

Inside door5B

Inside door5C

5E

Inside door

Inside door

A22

5A OR

OR

OR

10

14

a1

a4

b1

b5

R11 Fixing plate:

b2

Page 14: Instruction Manual Malanda/Avalon

14

7

8

7A

OR

7B

7C

7D

7E

8A

8B

8D

8C

Inside door8E

s1

Inside door

Page 15: Instruction Manual Malanda/Avalon

15

9

24 hSILICONE

Silicone inside and outside ofthe shower (silicone not