52
INSULATED METAL COMPOSITE WALL SYSTEM ®

INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

I N S U L A T E D M E T A L C O M P O S I T E W A L L S Y S T E M

®

Page 2: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

V e r s a w a l l

For an attractive and efficient wall, where long vertical

spans are desired, single-component CENTRIA Versawall

is an excellent alternative to traditional multi-component

wall systems.

These metal composite panels are formed with a

galvanized steel face and liner with preformed joinery

and thick, rigid CFC-free foam insulation. The result

is a remarkably strong but lightweight panel with an

extraordinary spanning capability. Panel lengths are

available up to 40’ [12.19mm] with insulation values as

high as R 27 [RSI 4.9]. Versawall panels install quickly

and easily in any weather.

Available in over 70 standard colors – including

micas and metallics, and textured Duracast® finish –

Versawall is appropriate for virtually any building type.

Office buildings, schools, hospitals, arenas, stadiums,

warehouses and industrial plants can all benefit from

the strength, beauty and efficiency of Versawall.

C O V E R P H O T O :M U S E U M O F F L I G H T, M I L I TA R Y G A L L E R YS E AT T L E , WA

Concealed clip fastening system provides a clean uninterruptedsurface and ability for panels to accommodate seismic forces

High-efficiency 90% closed cell CFC-free foam insulation

Thermal break prevents conduction between face and liner panels

Weathertight double tongue-and-groove vertical joinery with factory-applied non-curing vapor-resistant sealant that provides a complete air and vapor barrier

Page 3: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

SPECIFICATIONS

SUBSTRATES

• Standard 26/26 gage [.45mm/.45mm], ASTM A653, Grade 37,G-90 galvanized steel face and liner with CFC-free insulated foam core

• Flat 22 gage [.75mm] face only• Optional gages available – consult CENTRIA

JOINERY

• Double tongue-and-groove joinery with factory-applied air and vapor seal

SURFACE FINISH

• Exterior – Non-directional embossing, striated, plankedor flat

• Interior – Non-directional embossing, planked

PANEL WIDTH

• 30” [762mm], 36” [914mm]

PANEL LENGTH

• 6’ [1.83m] to 40’ [12.19m] standard• Longer lengths available – consult CENTRIA

PANEL THICKNESS

• 2” [51mm], 2-3/4” [70mm], 4” [102mm]

“R” VALUE*

• 2” [51mm] depth – R14* [RSI 2.54]• 2-3/4” [70mm] depth – R19* [RSI 3.41]• 4” [102mm] depth – R27* [RSI 4.83]

*R-Values are based on ASTM C236 and C518 testing.Air films are included.

FINISHES AND COLORS

• Available in the industry’s widest variety of durablefinish systems in over 70 standard and unlimitedcustom colors, including micas and metallics

S T O C K T O N A R E N A A N D E V E N T C E N T E RS T O C K T O N , C A

T U L S A T E C H N O LO G Y C E N T E RT U L S A , O K 2

a l l i n o n e

STRIATED

PLANKED

FLAT

Exterior30” [762] or 36” [914mm]

2” [51mm],2-3/4” [70mm] or 4” [102mm]

Interior

Exterior30” [762] or 36” [914mm]

2” [51mm],2-3/4” [70mm] or 4” [102mm]

Interior

Exterior30” [762] or 36” [914mm]

2” [51mm],2-3/4” [70mm] or 4” [102mm]

Interior

Page 4: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

V e r s a w a l l

Architects and owners also appreciate the environmental

benefits of Versawall.

In just one component – comprised of a limited amount

of material, with a high degree of both recycled and

recyclable content – a complete, long-lasting, energy-

efficient exterior wall is created.

Versawall’s efficient, rigid CFC-free foam insulation

does not harm the ozone layer, and materials such as

batt insulation, gypsum sheathing and building wrap

are entirely eliminated.

Plus, because Versawall is so lightweight – as light as

2.10 lbs./ft2 [10.25 kg/sqm]– a building’s structural and

foundation requirements can be dramatically reduced.

Architects frequently use the interior side of Versawall as the finished interior wall – further reducing material usage.

3

COMBINE VERSAWALL WITH A DURABLE TEXTURED FINISH

For a faster, easier and more economical alternative toprecast concrete, specify Versawall with CENTRIADuracast® textured finish. This permanent, nonabsorbentacrylic and silica aggregate coating is available in yourchoice of eight subtle earthtones. (Available on FlatEmbossed and Planked only.)

VERSAWALL WITH DURACAST

s i m p l y as o l u t i o n

U . S . N AV Y WA R E H O U S EN O R F O L K , VA

FLAT EMBOSSED

Page 5: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VVEERRSSAAWWAALLLL MMEEEETTSS OORR EEXXCCEEEEDDSS RREEQQUUIIRREEMMEENNTTSS OOFF TTHHEESSEE TTEESSTTSS::

ASTM E 72 Structural performance test

ASTM C 236 Thermal transmission test

ASTM 283-73 Air infiltration test

ASTM E 1646 Water penetration test

ASTM E 84 (UL 723) Burning characteristic test

ASTM D 1929 Ignition temperature test

UL 263 Fire resistant rating test

MEA #330-05-M New York City approval(2” [51mm] panel)

FM 4880 Class 1 insulated wall or ceiling panel

4

Specify Versawall’s exterior surface with non-directionalembossing, either subtly striated or lightly planked. Theinterior surface finish is non-directional embossed andlightly planked.

STRIATED

PLANKED

M Y S T I C A Q UA R I U MM Y S T I C , C T

U . S . N AV Y WA R E H O U S EN O R F O L K , VA

Page 6: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

V e r s a w a l l

• Provides excellent thermal efficiency and

moisture protection in a single component

• Lightweight panels with long spanning

capability reduce the building's structural

support requirements and reduce

installation costs

• Faster and easier installation in any type

of weather or climate

• Concealed clips and fasteners provide a

clean uninterrupted surface

• Available with preformed sheet metal

flashing or extruded aluminum trim

• Creates a complete, thermally efficient

exterior wall, using far less material

• Made of 100% recyclable steel with a

high degree of recycled content

• CENTRIA nationwide network of trained

dealers and installers

• Backed by CENTRIA, with over a century

of experience and excellence

B E N E F I T S O F V E R S A W A L L

5*Polyvinylidene Fluoride (PVDF) coat contains 70% Kynar 500 or Hylar

5000 resin. Kynar 500 is a Reg. TM of Arkema, Inc. Corporation. Hylar5000 is a Reg. TM of Solvay Solexis, Inc. Galvalume is a Reg. TM ofBIEC International, Inc.

t h a t b e g i n s w i t h p r o t e c t i v e c o a t i n g s

.8 mil nominal PVDF Coat3.0 mil nominal Versacor Ultra Barrier Coat

.8 mil nominal Polyvinylidene Fluoride Coat (clear)*

.8 mil nominal Primer Coat

.8 mil nominal Polyvinylidene Fluoride Coat (color)*

Substrate

.8 mil nominal Primer Coat

.8 mil nominal Polyvinylidene Fluoride Coat (color)*

Substrate

DURAGARD® PLUSA premium, high build architecturalcoating providing the ultimate in colorretention and fade resistance.

DURAGARD®

.5 mil nominal Polyvinylidene Fluoride Coat (clear)*

.2 mil nominal Primer Coat

.8 mil nominal Polyvinylidene Fluoride Coat (color)*

Substrate

METALLIC 3-COATA quality, durable coating providing theiridescence and reflectivity of a metallicsurface.

VERSACOR® ULTRA PFA premium, high build, multi-layercoating for applications wherecorrosion resistance is more important.

FLUOROFINISH® *, MICA* ANDBRILLIANT SERIESEconomical Kynar 500®, Hylar 5000®

or FEVE-based coating providinggood durability.

.2 mil nominal Primer CoatSubstrate

.8 mil nominal Color Coat

Acrylic and Natural Aggregate Matrix.8 mil nominal Polyester.2 mil nominal PrimerSubstrate

DURACASTA textured coating consisting of apermanent, non-absorbent acrylic andsilica coating. (Available on Versapanelwalls only)

VERSACOR® ULTRA TF AND HF

3.0 mil nominal Versacor Ultra Barrier Coat1.5 or 3.0 mil nominal Urethane Coat (color)*

Page 7: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VVersawall Detailsersawall Details

66

2008Versawall details.indd 6 10/22/08 2:29:10 AM

Page 8: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

7

PRODUCT INFORMATION

Versawall - Striated, Planked or Flat ..........8, 9

PRODUCT PROFILES

Versawall Striated..........................................10

Versawall Planked ........................................11

Versawall Embossed Flat ..............................12

Versawall Joint - 2.00 ....................................13

Versawall Joint - 2.75 ....................................14

Versawall Joint - 4.00 ....................................15

VERSAWALL APPLICATION DETAILS

Base at Curb w/ Extrusion ............................16

Base at Curb ................................................17

Base at Slab w/ Extrusion ............................18

Base at Slab ..................................................19

ATMP Base at Slab ......................................20

Stack Joint w/ Extrusion ................................21

ATMP Stack ..................................................22

Stack Joint ....................................................23

Parapet w/ Extrusion ....................................24

Parapet ..........................................................25

Head w/ Extrusion at Opening ......................26

ATMP Head at Opening ................................27

Head at Opening ..........................................28

Jamb w/ Extrusion ........................................29

ATMP Jamb at Opening ................................30

Jamb..............................................................31

Sill ..................................................................32

Wall - Soffit w/ Extrusion ..............................33

Soffit - Wall w/ Extrusion ..............................34

Wall - Soffit ....................................................35

Soffit - Wall ....................................................36

Jamb at Masonry w/ Extrusion ......................37

Jamb at Masonry ..........................................38

Inside Corner w/ Extrusion ............................39

Inside Corner ................................................40

Outside Corner w/ Extrusion ........................41

Outside Corner ..............................................42

Expansion Joint w/ Extrusion ........................43

Expansion Joint ............................................44

LOAD / SPAN TABLES

30” Versawall Wind Load ........................45, 46

36” Versawall Wind Load ........................47, 48

INDEX

CENTRIA reserves the right to change information in this manual without prior notice.

This manual illustrates design information and application details for CENTRIA Versawall products. The information contained herein is not intended to assure performance for each particular application. CENTRIA accepts no liability arising from the use of this information and excludes any implied warranty of fitness for a particular purpose or merchantablility with respect to the products described.

2008Versawall details.indd 7 10/22/08 2:29:10 AM

Page 9: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

20, 22, 24 ga. embossed, planked

Versawall 4.00 - U=0.036 (R=27.34)Versawall 2.75 - U=0.049 (R=20.24)Versawall 2.00 - U=0.069 (R=14.41)

Versawall wall panels incorporate a finished interior liner, factory applied air and vapor seal,insulating foam core and finished exterior weathering surface into a single building unit.The composite action resulting from the chemical bond between the poured in place foamcore and the steel skins creates a lightweight, rigid unit with excellent spanning capacity.

Double Tongue & Groove

20, 22, 24 ga. embossed and striated

26 ga. embossed and striated or

26 ga. embossed, planked

Non-directional embossing

(optional)

(standard)

(optional)

(standard)

(standard)(optional)(optional)(standard)

Interior Liner

Lengths

Texture

Finishes

Core Material

Thermal Properties

Exterior Face

Base Material

6 ft. to 40 ft. (36 ft max. for flat face)1 ft. min. to 6 ft.40 ft. to 48 ft. max.

See Finishes Brochure

Isocyanurate foam

G-90 galvanized steel

Panel ThicknessPanel Module

End JointSide Joint

Panel Availability2", 2 3/4", or 4"30", 36"

Butt - see DetailsInformation is available on special applications such asfire-rated walls, corrosive exposure considerations,pressure release walls, special material and coatingrequirements as well as many other pertinent subjects;contact your local CENTRIA Sales Representative.

Maximum support spacing & panel length may belimited for medium & dark colors due to thermalstress, consult CENTRIA Design & Developement.

Brake-formed flashings

Extruded flashings

Others as required for job completion

Attachment clips

1.Notes

Accessories

2.3.4.5.

1.

7.8.

6.

Flat stock

Windows (2" thick panels only)

FastenersSealants

Special Applications

Oct08

VERSAWALL PROMOTIONALDATA # 0001

4. A METRIC version of this Tech Data sheet isavailable (see Promotional Data #0001m).

*

"Rounded R-values based on ASTM C1363test .... air films included"

*

(standard)(optional)

Profiles striated (face only)planked

26 ga. embossed and planked

20, 22, 24 ga. embossed and planked22 ga. embossed and flat

(optional) embossed flat (face only)

2. Flat faced panel maximum length for light andmedium colors is 36'. For dark colors maximumlength is 20'-9".

3. 4" thick panels are not available with a flat face.

PANEL MODULE

1/8" JOINT

PANEL MODULE

PANEL MODULE PANEL MODULE

1/8" JOINT

2.00 PANEL JOINT 2.75 PANEL JOINT(4.00 PANEL JOINT SIMILAR)

8

2008Versawall details.indd 8 10/22/08 2:29:11 AM

Page 10: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

.90, .75, .60mm embossed, planked

Versawall 102mm - U=0.207 (RSI=4.84)Versawall 70mm - U=0.278 (RSI=3.59)Versawall 51mm - U=0.392 (RSI=2.55)

Versawall wall panels incorporate a finished interior liner, factory applied air and vapor seal,insulating foam core and finished exterior weathering surface into a single building unit.The composite action resulting from the chemical bond between the poured in place foamcore and the steel skins creates a lightweight, rigid unit with excellent spanning capacity.

Double Tongue & Groove

.90, .75, .60mm embossed, striatedor planked

.45mm embossed, striated or planked

.45mm embossed, planked

Non-directional embossing

(optional)

(standard)(optional)

(standard)

(standard)(optional)(optional)(standard)

Interior Liner

Lengths

Texture

Finishes

Core Material

Thermal Properties

Exterior Face

Base Material

1.83m to 12.19m (see note 2).3m min. to 1.83m12.19m to 14.63m max.

See Finishes Brochure

Isocyanurate foam

G-90 galvanized steel

Panel ThicknessPanel Module

End JointSide Joint

Panel Availability51mm, 70mm or 102mm762mm, 914mm

Butt - see DetailsInformation is available on special applications such asfire-rated walls, corrosive exposure considerations,pressure release walls, special material and coatingrequirements as well as many other pertinent subjects;contact your local CENTRIA Sales Representative.

Brake-formed flashings

Extruded flashings

Others as required for job completion

Attachment clips

Accessories

2.3.4.5.

1.

7.8.

6.

Flat stock

Windows (51mm thick panels only)

FastenersSealants

Special Applications

Oct08

PROMOTIONALDATA # 0001_m

U{W/(m K)}2*

"Rounded R-values based on ASTM C1363 test .... air films included"

*

(standard)(optional)

Profiles striated (face only)planked

VERSAWALL SI Units

Maximum support spacing & panel length may belimited for medium & dark colors due to thermalstress, consult CENTRIA Design & Developement.

1.Notes

2. Flat faced panel maximum length for light andmedium colors is 10.9m. For dark colorsmaximum length is 6.32m.

3. 102mm thick panels are not available with aflat face.

.75mm embossed, flat

(optional) embossed flat (face only)

PANEL MODULE

3mm JOINT

PANEL MODULE

PANEL MODULE PANEL MODULE

3mm JOINT

51mm PANEL JOINT 70mm PANEL JOINT(102mm PANEL JOINT SIMILAR)

9

2008Versawall details.indd 9 10/22/08 2:29:12 AM

Page 11: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

STR

IATE

D V

ER

SAW

ALL

VERSAWALL PROMOTIONALPROFILE # 0001

Oct08

10

2008Versawall details.indd 10 10/22/08 2:29:13 AM

Page 12: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

PLA

NK

ED

VE

RS

AWAL

L

VERSAWALL PROMOTIONALPROFILE # 0002

Oct08

11

2008Versawall details.indd 11 10/22/08 2:29:14 AM

Page 13: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

FLA

T V

ER

SAW

ALL

VERSAWALL PROMOTIONALPROFILE # 0003

Oct08

12

2008Versawall details.indd 12 10/22/08 2:29:15 AM

Page 14: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

Oct08

VERSAWALL PROMOTIONALPROFILE # 0004

13

2008Versawall details.indd 13 10/22/08 2:29:16 AM

Page 15: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALL

14

2008Versawall details.indd 14 10/22/08 2:29:16 AM

Page 16: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

Oct08

PROMOTIONALPROFILE # 0006VERSAWALL

15

2008Versawall details.indd 15 10/22/08 2:29:17 AM

Page 17: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

16

2008Versawall details.indd 16 10/22/08 2:29:17 AM

Page 18: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

17

2008Versawall details.indd 17 10/22/08 2:29:18 AM

Page 19: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

18

2008Versawall details.indd 18 10/22/08 2:29:19 AM

Page 20: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

19

2008Versawall details.indd 19 10/22/08 2:29:19 AM

Page 21: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPE

20

2008Versawall details.indd 20 10/22/08 2:29:20 AM

Page 22: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

21

2008Versawall details.indd 21 10/22/08 2:29:20 AM

Page 23: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPE

22

2008Versawall details.indd 22 10/22/08 2:29:21 AM

Page 24: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

23

2008Versawall details.indd 23 10/22/08 2:29:22 AM

Page 25: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

24

2008Versawall details.indd 24 10/22/08 2:29:22 AM

Page 26: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

25

2008Versawall details.indd 25 10/22/08 2:29:23 AM

Page 27: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

26

2008Versawall details.indd 26 10/22/08 2:29:23 AM

Page 28: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPE

27

2008Versawall details.indd 27 10/22/08 2:29:24 AM

Page 29: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

28

2008Versawall details.indd 28 10/22/08 2:29:25 AM

Page 30: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

29

2008Versawall details.indd 29 10/22/08 2:29:25 AM

Page 31: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPE

30

2008Versawall details.indd 30 10/22/08 2:29:26 AM

Page 32: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

31

2008Versawall details.indd 31 10/22/08 2:29:26 AM

Page 33: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

32

2008Versawall details.indd 32 10/22/08 2:29:27 AM

Page 34: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

33

2008Versawall details.indd 33 10/22/08 2:29:27 AM

Page 35: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

34

2008Versawall details.indd 34 10/22/08 2:29:28 AM

Page 36: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

35

2008Versawall details.indd 35 10/22/08 2:29:29 AM

Page 37: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

36

2008Versawall details.indd 36 10/22/08 2:29:29 AM

Page 38: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

37

2008Versawall details.indd 37 10/22/08 2:29:30 AM

Page 39: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

38

2008Versawall details.indd 38 10/22/08 2:29:31 AM

Page 40: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

39

2008Versawall details.indd 39 10/22/08 2:29:31 AM

Page 41: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

40

2008Versawall details.indd 40 10/22/08 2:29:32 AM

Page 42: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

41

2008Versawall details.indd 41 10/22/08 2:29:33 AM

Page 43: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

42

2008Versawall details.indd 42 10/22/08 2:29:33 AM

Page 44: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

43

2008Versawall details.indd 43 10/22/08 2:29:34 AM

Page 45: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

VERSAWALLPANEL TYPES

44

2008Versawall details.indd 44 10/22/08 2:29:35 AM

Page 46: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

Thickness Gage No.(in.) Face/Liner Spans 20 25 30 35 40 45 50 55 60

1 12'-0''* 11'-5'' 9'-6'' 8'-2'' 7'-2'' 6'-4'' 5'-9'' 5'-2'' 4'-9''2 12'-0''* 12'-0''* 11'-7'' 10'-0'' 8'-10'' 7'-11'' 7'-1'' 6'-4'' 5'-9''3 12'-0''* 12'-0''* 11'-9'' 10'-1'' 8'-9'' 7'-9'' 7'-0'' 6'-3'' 5'-9''1 12'-0''* 12'-0''* 12'-0''* 10'-6'' 9'-2'' 8'-2'' 7'-4'' 6'-8'' 6'-2''2 12'-0''* 12'-0''* 11'-9'' 10'-2'' 9'-0'' 8'-0'' 7'-3'' 6'-8'' 6'-2''3 12'-0''* 12'-0''* 12'-0''* 10'-7'' 9'-4'' 8'-4'' 7'-6'' 6'-10'' 6'-4''1 12'-0''* 11'-5'' 9'-6'' 8'-2'' 7'-2'' 6'-4'' 5'-9'' 5'-2'' 4'-9''2 12'-0''* 12'-0''* 11'-8'' 10'-1'' 8'-11'' 7'-10'' 7'-0'' 6'-2'' 5'-7''3 12'-0''* 12'-0''* 11'-9'' 10'-0'' 8'-9'' 7'-8'' 6'-11'' 6'-3'' 5'-8''1 12'-0''* 12'-0''* 12'-0''* 10'-6'' 9'-2'' 8'-2'' 7'-4'' 6'-8'' 6'-2''2 12'-0''* 12'-0''* 11'-10'' 10'-3'' 9'-1'' 8'-2'' 7'-5'' 6'-9'' 6'-3''3 12'-0''* 12'-0''* 12'-0''* 11'-2'' 9'-9'' 8'-9'' 7'-10'' 7'-2'' 6'-7''1 12'-0''* 11'-8'' 9'-8'' 8'-4'' 7'-3'' 6'-6'' 5'-10'' 5'-3'' 4'-10''2 12'-0''* 12'-0''* 11'-9'' 10'-2'' 8'-10'' 7'-9'' 6'-10'' 6'-2'' 5'-7''3 12'-0''* 12'-0''* 11'-11'' 10'-1'' 8'-9'' 7'-9'' 7'-0'' 6'-3'' 5'-8''1 12'-0''* 12'-0''* 12'-0''* 12'-0''* 11'-0'' 9'-9'' 8'-9'' 8'-0'' 7'-3''2 12'-0''* 12'-0''* 12'-0'' 10'-5'' 9'-2'' 8'-3'' 7'-6'' 6'-11'' 6'-5''3 12'-0''* 12'-0''* 12'-0''* 11'-2'' 9'-10'' 8'-9'' 8'-0'' 7'-3'' 6'-8''

Thickness Gage No.(in.) Face/Liner Spans 20 25 30 35 40 45 50 55 60

1 12'-0''* 11'-0'' 9'-2'' 7'-10'' 6'-11'' 6'-1'' 5'-6'' 5'-0'' 4'-7''2 11'-3'' 9'-1'' 7'-8'' 6'-8'' 5'-10'' 5'-3'' 4'-9'' 4'-5'' 4'-1''3 12'-0''* 10'-1'' 8'-5'' 7'-3'' 6'-4'' 5'-8'' 5'-1'' 4'-8'' 4'-3''1 12'-0''* 11'-0'' 9'-2'' 7'-10'' 6'-11'' 6'-1'' 5'-6'' 5'-0'' 4'-7''2 11'-5'' 9'-3'' 7'-10'' 6'-9'' 6'-0'' 5'-5'' 4'-11'' 4'-6'' 4'-2''3 12'-0''* 10'-1'' 8'-5'' 7'-3'' 6'-4'' 5'-8'' 5'-2'' 4'-8'' 4'-4''1 12'-0''* 11'-0'' 9'-2'' 7'-10'' 6'-11'' 6'-1'' 5'-6'' 5'-0'' 4'-7''2 11'-4'' 9'-2'' 7'-9'' 6'-9'' 6'-0'' 5'-4'' 4'-10'' 4'-6'' 4'-2''3 12'-0''* 10'-1'' 8'-5'' 7'-3'' 6'-4'' 5'-8'' 5'-1'' 4'-8'' 4'-4''1 12'-0''* 11'-0'' 9'-2'' 7'-10'' 6'-11'' 6'-1'' 5'-6'' 5'-0'' 4'-7''2 11'-6'' 9'-4'' 7'-11'' 6'-11'' 6'-1'' 5'-6'' 5'-0'' 4'-7'' 4'-3''3 12'-0''* 10'-1'' 8'-6'' 7'-3'' 6'-5'' 5'-9'' 5'-2'' 4'-9'' 4'-4''1 12'-0''* 11'-0'' 9'-2'' 7'-10'' 6'-11'' 6'-1'' 5'-6'' 5'-0'' 4'-7''2 11'-5'' 9'-3'' 7'-10'' 6'-10'' 6'-1'' 5'-5'' 5'-0'' 4'-7'' 4'-2''3 12'-0''* 10'-1'' 8'-6'' 7'-3'' 6'-5'' 5'-8'' 5'-2'' 4'-8'' 4'-4''1 12'-0''* 11'-0'' 9'-2'' 7'-10'' 6'-11'' 6'-1'' 5'-6'' 5'-0'' 4'-7''2 11'-8'' 9'-6'' 8'-1'' 7'-0'' 6'-3'' 5'-7'' 5'-1'' 4'-8'' 4'-4''3 12'-0''* 10'-2'' 8'-6'' 7'-4'' 6'-5'' 5'-9'' 5'-3'' 4'-9'' 4'-5''

Explanatory Notes for Load/Span Table:1. Spans are limited to a maximum deflection of L/120 for positive wind load.2. Spans are based on 1 fastener with an allowable pullout capacity of 1064 lb. per interior clip when fastened into 3/16" steel supports and 2 fasteners with an allowable pullout capacity of 344 lb. each per interior clip when fastened into 16 Ga. supports.3. Spans for 26/26 gage panels shown above are valid for 22/26 gage panels.4. * Spans limited by thermal stress and thermal bow considerations. For dark colored panels, further panel length and span restrictions may be necessary due to thermal stress. Contact CENTRIA.5. Contact CENTRIA for conditions not conforming to these notes.

22/22

22/22

26/26

4.00

26/26

26/26

22/22

22/22

26/26

22/22

2.00

2.75

Load-psf

Load - psf

30" Module Panel Fastened into 16 Gage Steel Supports

30" Module Panel Fastened into 3/16" Steel Supports

4.00

2.00

26/26

22/22

2.75

26/26

VERSAWALL

Oct 08 45

2008Versawall details.indd 45 10/22/08 2:29:37 AM

Page 47: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

46

VERSAWALL

Metric Wind Loads for 30" ModuleVersawall Wall PanelsOct 08

Thickness Gage No.(mm) Face/Liner Spans 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00

1 3.66* 3.33 2.78 2.38 2.08 1.85 1.67 1.52 1.392 3.66* 3.66* 3.39 2.92 2.58 2.31 2.05 1.84 1.673 3.66* 3.66* 3.44 2.93 2.55 2.26 2.02 1.83 1.671 3.66* 3.66* 3.58 3.07 2.68 2.39 2.15 1.95 1.792 3.66* 3.66* 3.43 2.97 2.62 2.35 2.13 1.96 1.813 3.66* 3.66* 3.60 3.09 2.72 2.43 2.20 2.00 1.841 3.66* 3.33 2.78 2.38 2.08 1.85 1.67 1.52 1.392 3.66* 3.66* 3.41 2.95 2.59 2.27 2.01 1.80 1.633 3.66* 3.66* 3.42 2.92 2.54 2.24 2.01 1.81 1.651 3.66* 3.66* 3.58 3.07 2.68 2.39 2.15 1.95 1.792 3.66* 3.66* 3.46 3.00 2.65 2.38 2.16 1.99 1.843 3.66* 3.66* 3.66* 3.26 2.86 2.55 2.30 2.10 1.931 3.66* 3.39 2.83 2.42 2.12 1.89 1.70 1.54 1.412 3.66* 3.66* 3.44 2.98 2.58 2.25 1.99 1.78 1.613 3.66* 3.66* 3.46 2.95 2.56 2.26 2.02 1.81 1.651 3.66* 3.66* 3.66* 3.65 3.19 2.84 2.55 2.32 2.132 3.66* 3.66* 3.51 3.05 2.70 2.42 2.20 2.02 1.873 3.66* 3.66* 3.66* 3.27 2.87 2.56 2.31 2.11 1.94

Thickness Gage No.(in.) Face/Liner Spans 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00

1 3.66* 3.21 2.68 2.30 2.01 1.79 1.61 1.46 1.342 3.29 2.66 2.24 1.94 1.72 1.54 1.40 1.29 1.193 3.66* 2.94 2.45 2.11 1.85 1.65 1.49 1.36 1.251 3.66* 3.21 2.68 2.30 2.01 1.79 1.61 1.46 1.342 3.31 2.70 2.29 1.98 1.76 1.58 1.44 1.32 1.223 3.66* 2.95 2.47 2.12 1.86 1.66 1.50 1.37 1.261 3.66* 3.21 2.68 2.30 2.01 1.79 1.61 1.46 1.342 3.33 2.69 2.27 1.97 1.74 1.57 1.43 1.31 1.213 3.66* 2.94 2.46 2.12 1.86 1.66 1.50 1.37 1.261 3.66* 3.21 2.68 2.30 2.01 1.79 1.61 1.46 1.342 3.36 2.74 2.32 2.02 1.79 1.61 1.46 1.34 1.243 3.66* 2.96 2.48 2.13 1.87 1.67 1.51 1.38 1.271 3.66* 3.21 2.68 2.30 2.01 1.79 1.61 1.46 1.342 3.35 2.72 2.30 2.00 1.77 1.60 1.45 1.33 1.233 3.66* 2.95 2.47 2.13 1.87 1.67 1.51 1.38 1.271 3.66* 3.21 2.68 2.30 2.01 1.79 1.61 1.46 1.342 3.41 2.78 2.36 2.05 1.82 1.64 1.49 1.37 1.263 3.66* 2.97 2.49 2.14 1.89 1.69 1.52 1.39 1.28

Explanatory Notes for Load/Span Table:1. Spans given in meters.2. Spans are limited to a maximum deflection of L/120 for positive wind load.3. Spans are based on 1 fastener with an allowable pullout capacity of 483 kg (1064 lb) per interior clip when fastened into 3/16" steel supports and 2 fasteners with an allowable pullout capacity of 156 kg (344 lb) each per interior clip when fastened into 16 Ga. supports.4. Spans for 26/26 gage panels shown above are valid for 22/26 gage panels.5. * Spans limited by thermal stress and thermal bow considerations. For dark colored panels, further panel length and span restrictions may be necessary due to thermal stress. Contact CENTRIA.6. Contact CENTRIA for conditions not conforming to these notes.

762 mm (30") Module Panel Fastened into 4.75 mm (3/16") Steel Supports

102(4.00")

50(2.00")

26/26

22/22

70(2.75")

26/26

26/26

22/22

50(2.00")

70(2.75")

Load-psf

Load - kPa

762 mm (30") Module Panel Fastened into 1.50 mm (16 Gage) Steel Supports

22/22

22/22

26/26

102(4.00")

26/26

26/26

22/22

22/22

2008Versawall details.indd 46 10/22/08 2:29:39 AM

Page 48: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

47

Thickness Gage No.(in.) Face/Liner Spans 20 25 30 35 40 45 50 55 60

1 11'-11'' 9'-6'' 8'-0'' 6'-10'' 6'-0'' 5'-3'' 4'-9'' 4'-4'' 4'-0''2 12'-0''* 11'-7'' 9'-9'' 8'-5'' 7'-5'' 6'-6'' 5'-9'' 5'-2'' 4'-8''3 12'-0''* 11'-9'' 9'-9'' 8'-4'' 7'-3'' 6'-5'' 5'-9'' 5'-2'' 4'-9''1 12'-0''* 12'-0''* 10'-3'' 8'-9'' 7'-8'' 6'-10'' 6'-2'' 5'-7'' 5'-1''2 12'-0''* 11'-9'' 9'-10'' 8'-7'' 7'-7'' 6'-9'' 6'-2'' 5'-8'' 5'-3''3 12'-0''* 12'-0''* 10'-10'' 9'-4'' 8'-2'' 7'-3'' 6'-7'' 6'-0'' 5'-6''1 11'-11'' 9'-6'' 8'-0'' 6'-10'' 6'-0'' 5'-3'' 4'-9'' 4'-4'' 4'-0''2 12'-0''* 11'-8'' 9'-10'' 8'-5'' 7'-3'' 6'-4'' 5'-7'' 5'-0'' 4'-6''3 12'-0''* 11'-9'' 9'-9'' 8'-3'' 7'-2'' 6'-4'' 5'-8'' 5'-1'' 4'-8''1 12'-0''* 12'-0''* 10'-3'' 8'-9'' 7'-8'' 6'-10'' 6'-2'' 5'-7'' 5'-1''2 12'-0''* 11'-10'' 10'-0'' 8'-8'' 7'-8'' 6'-11'' 6'-3'' 5'-9'' 5'-4''3 12'-0''* 12'-0''* 10'-10'' 9'-4'' 8'-2'' 7'-4'' 6'-7'' 6'-0'' 5'-6''1 12'-0''* 9'-8'' 8'-1'' 7'-0'' 6'-1'' 5'-5'' 4'-10'' 4'-5'' 4'-0''2 12'-0''* 11'-9'' 10'-0'' 8'-5'' 7'-2'' 6'-3'' 5'-7'' 5'-0'' 4'-6''3 12'-0''* 11'-11'' 9'-10'' 8'-4'' 7'-3'' 6'-4'' 5'-8'' 5'-1'' 4'-8''1 12'-0''* 12'-0''* 12'-0''* 10'-5'' 9'-1'' 8'-1'' 7'-3'' 6'-8'' 6'-1''2 12'-0''* 12'-0''* 10'-2'' 8'-10'' 7'-10'' 7'-0'' 6'-5'' 5'-10'' 5'-5''3 12'-0''* 12'-0''* 10'-11'' 9'-5'' 8'-3'' 7'-4'' 6'-8'' 6'-1'' 5'-7''

Thickness Gage No.(in.) Face/Liner Spans 20 25 30 35 40 45 50 55 60

1 11'-6'' 9'-2'' 7'-8'' 6'-7'' 5'-9'' 5'-1'' 4'-7'' 4'-2'' 3'-10''2 9'-5'' 7'-8'' 6'-6'' 5'-7'' 5'-0'' 4'-6'' 4'-1'' 3'-9'' 3'-5''3 10'-6'' 8'-5'' 7'-0'' 6'-0'' 5'-4'' 4'-9'' 4'-3'' 3'-11'' 3'-7''1 11'-6'' 9'-2'' 7'-8'' 6'-7'' 5'-9'' 5'-1'' 4'-7'' 4'-2'' 3'-10''2 9'-7'' 7'-10'' 6'-7'' 5'-9'' 5'-1'' 4'-7'' 4'-2'' 3'-10'' 3'-6''3 10'-6'' 8'-5'' 7'-1'' 6'-1'' 5'-4'' 4'-9'' 4'-4'' 4'-0'' 3'-7''1 11'-6'' 9'-2'' 7'-8'' 6'-7'' 5'-9'' 5'-1'' 4'-7'' 4'-2'' 3'-10''2 9'-6'' 7'-9'' 6'-7'' 5'-8'' 5'-0'' 4'-6'' 4'-2'' 3'-9'' 3'-6''3 10'-6'' 8'-5'' 7'-1'' 6'-1'' 5'-4'' 4'-9'' 4'-4'' 4'-0'' 3'-7''1 11'-6'' 9'-2'' 7'-8'' 6'-7'' 5'-9'' 5'-1'' 4'-7'' 4'-2'' 3'-10''2 9'-8'' 7'-11'' 6'-8'' 5'-10'' 5'-2'' 4'-8'' 4'-3'' 3'-11'' 3'-7''3 10'-6'' 8'-6'' 7'-1'' 6'-1'' 5'-5'' 4'-10'' 4'-4'' 4'-0'' 3'-8''1 11'-6'' 9'-2'' 7'-8'' 6'-7'' 5'-9'' 5'-1'' 4'-7'' 4'-2'' 3'-10''2 9'-8'' 7'-10'' 6'-8'' 5'-9'' 5'-2'' 4'-7'' 4'-2'' 3'-10'' 3'-7''3 10'-6'' 8'-6'' 7'-1'' 6'-1'' 5'-4'' 4'-9'' 4'-4'' 4'-0'' 3'-8''1 11'-6'' 9'-2'' 7'-8'' 6'-7'' 5'-9'' 5'-1'' 4'-7'' 4'-2'' 3'-10''2 9'-10'' 8'-1'' 6'-10'' 6'-0'' 5'-3'' 4'-9'' 4'-4'' 4'-0'' 3'-8''3 10'-7'' 8'-6'' 7'-2'' 6'-2'' 5'-5'' 4'-10'' 4'-5'' 4'-0'' 3'-8''

Explanatory Notes for Load/Span Table:1. Spans are limited to a maximum deflection of L/120 for positive wind load.2. Spans are based on 1 fastener with an allowable pullout capacity of 1064 lb. per interior clip when fastened into 3/16" steel supports and 2 fasteners with an allowable pullout capacity of 344 lb. each per interior clip when fastened into 16 Ga. supports.3. Spans for 26/26 gage panels shown above are valid for 22/26 gage panels.4. * Spans limited by thermal stress and thermal bow considerations. For dark colored panels, further panel length and span restrictions may be necessary due to thermal stress. Contact CENTRIA.5. Contact CENTRIA for conditions not conforming to these notes.

Load-psf

Load - psf

36" Module Panel Fastened into 16 Gage Steel Supports

36" Module Panel Fastened into 3/16" Steel Supports

4.00

2.00

26/26

22/22

2.75

26/26

4.00

26/26

26/26

22/22

22/22

26/26

22/22

2.00

2.75

22/22

22/22

26/26

VERSAWALL

Oct 08

2008Versawall details.indd 47 10/22/08 2:29:41 AM

Page 49: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

48

VERSAWALL

Metric Wind Loads for 36" Module Versawall Wall PanelsOct 08

Thickness Gage No.(mm) Face/Liner Spans 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00

1 3.47 2.78 2.32 1.98 1.74 1.54 1.39 1.26 1.162 3.66* 3.39 2.85 2.46 2.15 1.88 1.67 1.49 1.353 3.66* 3.44 2.85 2.43 2.11 1.87 1.67 1.51 1.371 3.66* 3.58 2.98 2.56 2.24 1.99 1.79 1.63 1.492 3.66* 3.43 2.89 2.50 2.22 1.99 1.81 1.66 1.533 3.66* 3.66* 3.16 2.72 2.38 2.12 1.92 1.75 1.611 3.47 2.78 2.32 1.98 1.74 1.54 1.39 1.26 1.162 3.66* 3.41 2.87 2.45 2.10 1.84 1.63 1.45 1.313 3.66* 3.42 2.84 2.41 2.09 1.85 1.65 1.48 1.351 3.66* 3.58 2.98 2.56 2.24 1.99 1.79 1.63 1.492 3.66* 3.46 2.92 2.54 2.25 2.02 1.84 1.69 1.563 3.66* 3.66* 3.17 2.73 2.39 2.14 1.93 1.76 1.621 3.54 2.83 2.36 2.02 1.77 1.57 1.41 1.29 1.182 3.66* 3.44 2.90 2.44 2.09 1.82 1.61 1.44 1.303 3.66* 3.46 2.86 2.43 2.10 1.85 1.65 1.48 1.351 3.66* 3.66* 3.55 3.04 2.66 2.36 2.13 1.94 1.772 3.66* 3.51 2.97 2.58 2.29 2.06 1.87 1.72 1.593 3.66* 3.66* 3.18 2.74 2.41 2.15 1.94 1.77 1.63

Thickness Gage No.(in.) Face/Liner Spans 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00

1 3.35 2.68 2.23 1.91 1.67 1.49 1.34 1.22 1.122 2.77 2.24 1.89 1.64 1.46 1.31 1.19 1.09 1.013 3.06 2.54 2.05 1.77 1.55 1.38 1.25 1.14 1.051 3.35 2.68 2.23 1.91 1.67 1.49 1.34 1.22 1.122 2.81 2.29 1.94 1.68 1.49 1.34 1.22 1.12 1.043 3.07 2.47 2.06 1.78 1.56 1.40 1.26 1.15 1.061 3.35 2.68 2.23 1.91 1.67 1.49 1.34 1.22 1.122 2.79 2.27 1.92 1.67 1.48 1.33 1.21 1.11 1.033 3.07 2.46 2.06 1.77 1.56 1.39 1.26 1.15 1.061 3.35 2.68 2.23 1.91 1.67 1.49 1.34 1.22 1.122 2.84 2.32 1.97 1.71 1.52 1.37 1.24 1.14 1.053 3.08 2.48 2.07 1.79 1.57 1.41 1.27 1.16 1.071 3.35 2.68 2.23 1.91 1.67 1.49 1.34 1.22 1.122 2.83 2.30 1.95 1.70 1.51 1.36 1.23 1.13 1.053 3.07 2.47 2.07 1.78 1.57 1.40 1.27 1.16 1.061 3.35 2.68 2.23 1.91 1.67 1.49 1.34 1.22 1.122 2.89 2.36 2.00 1.74 1.55 1.39 1.26 1.16 1.073 3.09 2.49 2.09 1.80 1.59 1.42 1.28 1.17 1.08

Explanatory Notes for Load/Span Table:1. Spans given in meters.2. Spans are limited to a maximum deflection of L/120 for positive wind load.3. Spans are based on 1 fastener with an allowable pullout capacity of 483 kg (1064 lb) per interior clip when fastened into 3/16" steel supports and 2 fasteners with an allowable pullout capacity of 156 kg (344 lb) each per interior clip when fastened into 16 Ga. supports.4. Spans for 26/26 gage panels shown above are valid for 22/26 gage panels.5. * Spans limited by thermal stress and thermal bow considerations. For dark colored panels, further panel length and span restrictions may be necessary due to thermal stress. Contact CENTRIA.6. Contact CENTRIA for conditions not conforming to these notes.

915 mm (36") Module Panel Fastened into 4.75 mm (3/16") Steel Supports

102(4.00")

50(2.00")

26/26

22/22

70(2.75")

26/26

26/26

22/22

50(2.00")

70(2.75")

Load-psf

Load - kPa

915 mm (36") Module Panel Fastened into 1.50 mm (16 Gage) Steel Supports

22/22

22/22

26/26

102(4.00")

26/26

26/26

22/22

22/22

2008Versawall details.indd 48 10/22/08 2:29:44 AM

Page 50: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

Notes

2008Versawall details.indd 49 10/22/08 2:29:44 AM

Page 51: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

Notes

2008Versawall details.indd 50 10/22/08 2:29:45 AM

Page 52: INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM D 1929 Ignition temperature test UL 263 Fire resistant rating test MEA #330-05-M

800.759.74741005 Beaver Grade Road, Moon Township, PA 15108-2944

412.299.8000; Fax: 412.299.8317

Reference VWDM-10/08-10M-NJ/GCS Copyright © 2008 CENTRIA Printed in U.S.A.

w w w . C E N T R I A . c o m