  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    1/26

    Integrating DellPowerEdge Servers into

    an EnvironmentManaged by HP Systems

    Insight Manager 5.0

    Del l OpenManageSystem s Management

    Del l Whit e Paper

    By Niven BrooksOnsite Systems Engineer

    [email protected]

    December 2005

    Version 1

    mailto:[email protected]:[email protected]
  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    2/26

    Contents

    Introduction...................................................................................................................................4 TestConfiguration .......................................................................................................................6

    TypographicalConventions.................................................................................................6 LoadingandConfiguringServerAdministrator....................................................................7

    WhatSNMPconfigurationshouldIuse?..........................................................................7 UsingtheDellInstallationandServerManagementCDtoloadtheOSandSNMP .......................................................................................................................................8SNMPConfigurationafterOSinstallation ......................................................................8LoadingServerAdministrator.............................................................................................9 Testing....................................................................................................................................11

    LoadingtheDellMIBs ..............................................................................................................12UploadingtheDellMIBs ...................................................................................................13CompilingtheMIBs............................................................................................................13 RegisteringtheMIBs...........................................................................................................14

    SystemTypeManager ...............................................................................................................15DiscoveringNewDellServers.................................................................................................20

    SettingGlobalProtocolSettings.......................................................................................20 ManuallyDiscoveringaDellServer................................................................................21

    TestingforEvents.......................................................................................................................22 GenerateanEvent................................................................................................................22

    Results ..........................................................................................................................................24LimitationsandCaveats: ....................................................................................................24

    AppendixA

    Dell

    MIBs...........................................................................................................25

    EssentialServerMIBs .........................................................................................................25NetworkInterfaceAdapters ..............................................................................................25OtherAdapters,Devices,andSoftware...........................................................................26 LegacyMIBs..........................................................................................................................26

    December 2005 Page 2

  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    3/26

    FiguresFigure1:ArchitectureoftheTestedEnvironment.................................................................................. 6Figure2:SettingTrapsandSecurity ......................................................................................................... 9Figure3:CustomSetupInstallationOptions......................................................................................... 10Figure4:TestingthePowerEdgeServerwithSNMPWALK .............................................................. 11Figure5:DellMIBsonhttp://support.dell.com..................................................................................... 12Figure6:Runningmcompileandmxmib .............................................................................................. 14Figure7:RetrieveOIDfromsystem ....................................................................................................... 16Figure8:RetrievevariablefromMIB...................................................................................................... 17Figure9:Getresponse............................................................................................................................... 18Figure10:CompletedSystemTypeDialog............................................................................................ 19Figure11:GlobalProtocolSettings ......................................................................................................... 20Figure12:ManualDiscovery................................................................................................................... 21Figure13:AllEvents ................................................................................................................................. 23

    December 2005 Page 3

  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    4/26

    Sect ion 1

    I n t roduc t i on

    Inresponsetothepressureforincreasedproductivityofsystemadministrators,

    servervendorshaverespondedwithmanagementtools. Dellsofferingisthe

    DellOpenManagesuiteofproducts. Whiletheseproductscoversoftware

    deployment,hardwareconfiguration,assetmanagement,remotesupport,and

    systemhealthmonitoring,thispaperisfocusedonmonitoringsystemhealthon

    acollectionofservers.

    TodothisusingDellsOpenManagetools,OpenManageServerAdministrator

    instrumentationisinstalledonsupported*DellPowerEdgeservers,andone

    instanceof

    OpenManage

    IT

    Assistant

    is

    installed

    and

    configured

    for

    monitoring

    theinstrumentedPowerEdgeservers. ErrorsdetectedbyServerAdministrator

    arethenforwardedviaSimpleNetworkManagementProtocol(SNMP)toIT

    Assistant,wheretheyareloggedandcangenerateemailandpaging

    notifications.

    SinceaHewlettPackardSystemsInsightManager5.0environmenthasthe

    samearchitecture,itispossibletointegrateinstrumentedDellPowerEdge

    serversintoHPSIMbytakingadvantageoftheindustrystandardinterfacesof

    SNMPandHypertextTransportProtocolSecure(HTTPS)inServer

    Administrator. Thisallowsadministratorstocontinuetousetheirexisting

    HPSIMbasednotificationprocesseswhilefullybenefitingfromtheuseofServer

    Administratoron

    supported*

    Dell

    servers.

    HPSIM5.0hassomebuiltinthirdpartydevicesupport,includingsomeDell

    servers. InsomecasestheDellservercanbedetectedandmanagedfromthe

    defaultHPSIMinstallationwithoutanyfurthercustomization. However,the

    builtinthirdpartydevicesupportmaynotbecomprehensive,especiallyfor

    newerPowerEdgemodels,anditisrecommendedthattheDellprovidedMIBs

    areusedtomonitorDellservers.

    ThispaperdetailsthespecificstepsneededtoaddaDellPowerEdgeserver

    runningMicrosoftWindows2000Serveror2003StandardServertoan

    environmentcurrentlybeingmanagedbyHPSIM5.0. Toaddaserverrunning

    NetWareorLinux,theHPSIMandOpenManageServerAdministrator

    configurationwouldbethesame,withtheprimarydifferencebeinghow

    OpenManageisinstalledandSNMPisconfiguredateachmanagedPowerEdge

    server.

    December 2005 Page 4

  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    5/26

    Atahighlevel,thestepsforintegratingDellPowerEdgeserversintoan

    environmentmanagedbyHPSystemsInsightManagerare:

    1. LoadandconfigureOpenManageServerAdministratorontheDell

    serversoitcancommunicatewithHPSIM.

    2. LoadDellMIBSintoHPSIMsoitcanproperlycommunicatewithServer

    Administrator.

    3. ConfigureHPSIMtorecognizeDellservers.

    4. Generatesometestevents.

    *TheCompatibilityMatrixforServerAdministratorisavailableon

    http://support.dell.comunderServerAdministratordocumentation. Forexample,tosee

    thelistofServerAdministratorversion2.2andearliersupportedapplicationsand

    systems,pleaseseethecompatibilitymatrixat

    http://support.dell.com/support/edocs/software/svradmin/2.2/en/CompGD/4admnver.ht

    m#1072727.

    December 2005 Page 5

    http://support.dell.com/http://support.dell.com/support/edocs/software/svradmin/2.2/en/CompGD/4admnver.htm#1072727http://support.dell.com/support/edocs/software/svradmin/2.2/en/CompGD/4admnver.htm#1072727http://support.dell.com/support/edocs/software/svradmin/2.2/en/CompGD/4admnver.htm#1072727http://support.dell.com/support/edocs/software/svradmin/2.2/en/CompGD/4admnver.htm#1072727http://support.dell.com/
  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    6/26

    Sect ion 2

    Test Conf igurat ion

    ToprovideanexampleofhowtointegrateDellPowerEdgeserversintoan

    environmentmanagedbyHPSystemsInsightManager5.0,twoDellPowerEdge

    serverswereconfiguredtoreporttooneinstanceofHPSIM. WindowsServer

    2003wasinstalledonaDellPowerEdge500SC,Windows2000Serverwas

    installedonaPowerEdge2650,andWindowsXPProfessionalwasinstalledona

    DellPrecisionM70. TheDellInstallationandServerManagementCD4.5,which

    includesServerAdministrator2.2andStorageManagementService1.2,was

    usedtoinstalltheoperatingsystemandmanagementsoftwareonbothDell

    PowerEdgeservers. HPSystemsInsightManager5.00.00.02wasinstalledonthe

    DellPrecisionM70alongwithHPSIMsdefaultinstallationofMSDE.

    Figure 1: Architecture of the Tested Environment

    Typographical Conventions

    Forclarity

    of

    navigation

    of

    this

    paper,

    the

    following

    conventions

    are

    used:

    Boldisusedtoindicatethetitleofawindow,button,orlink.

    Italicsindicatesnotes

    UnderlinedtextindicatesaURL.

    December 2005 Page 6

  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    7/26

    Sect ion 3

    Loading and Conf igur ing ServerAdmin is t ra to r

    ThefirststepistoproperlyloadandconfiguretheDellserverasthemanaged

    systemtotalktoHPSIM5.0. Iftheoperatingsystem(OS)hasnotyetbeen

    loaded,thentheeasiestprocessistousetheDellInstallationandServer

    ManagementCDtobothloadMicrosoftWindowsandconfigureSNMP. Ifthe

    OShasalreadybeenloaded,thenonlySNMPneedstobeinstalledand

    configured. OnceSNMPisconfigured,OpenManageServerAdministratorcan

    beinstalled.

    What SNMP configuration should I use?

    ThedefaultSNMPcommunitynameispublic,butusingthatcouldallowa

    roguemanagementstationtoaccessyourservers. TheSNMPcommunityname

    islikeapasswordbothHPSIMandServerAdministratorneedtocommunicate.

    Toenhancesecurity,accesscanbereadonly. ThisprohibitsusingSNMPto

    makechangestotheserver,suchaschangingthresholdsettingsorshuttingit

    down,butallowsServerAdministratortosendalertstoaconsolewhenstatus

    changes. ADellPowerEdgeservercanfunctioninareadonlySNMP

    environment,but

    it

    is

    possible

    that

    other

    devices

    need

    SNMP

    set

    to

    read

    write.

    IftheintentwereforHPSIMandITAssistanttocoexistinthenetworkto

    providethefullOpenManagecapabilities,thenitwouldbenecessaryto

    configuretheDellPowerEdgeserverwithreadwriteSNMPpermissions. Inthis

    wayITAssistantcanperformconfigurationsettingsremotelyonthemanaged

    Dellserver. NotethatDellsecuresReadWriteoperationsusingSNMPonlyto

    comefromDellOpenManageITAssistant.

    SNMPtrapdestinationsalsoneedtobespecified. ThesearethehostnamesorIP

    addressesofoneormoresystemsthataretoreceivenotificationofevents.

    Forthis

    paper,

    the

    community

    name

    of

    showcase

    with

    read

    only

    rights

    was

    used

    withasingletrapdestinationtothePrecisionM70runningHPSIM. These

    settingsneedtobemadeoneachDellserveraddedtotheenvironment.

    December 2005 Page 7

  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    8/26

    Using the Dell Installation and Server Management CD to load the OS andSNMP

    OneoftheCDsthatshipswitheveryDellPowerEdgeserveristheDell

    InstallationandServerManagementCD. ThisCDisbootableandisusedto

    performacompleteoperatingsysteminstallationfromlocalmedia. Itcopiesthe

    operatingsysteminstallationfilestotheserverandautomaticallyintegratesthe

    appropriateDelldriversandsoftwareintotheOSinstallationfiles.

    ThePowerEdge2650and500SCintheconfigurationtestedforthispaperwere

    bootedfromtheDellInstallationandServerManagementCDandthemenus

    werefolloweduntiltheEnterConfigurationInformationfor:MicrosoftWindows200xServerscreenwasreached. Onthatscreen,theAdvancedbuttonwasclickedtoshowtheadditionalsettingsthatcanbesetbyServerAssistant.

    InstallSNMPischeckedbydefault,butitisalsonecessarytoenteraCommunityNameandTrapDestinationandchangetheAcceptedCommunityNames

    from

    public:Read_Only

    to

    showcase:Read_Only.

    The

    rest

    of

    the

    defaultscanbeleftunchanged.

    SNMP Configuration After OS installation

    IftheServerAssistantCDhasnotbeenusedtoloadtheOSandconfigureSNMP,

    thenthefollowingstepsshouldbeperformed. Thefirstistoensurethatthe

    SNMPcomponentisinstalled. AfterselectingtheAdd/RemoveWindows

    ComponentsinthelefthandoftheAdd/RemoveProgramsdialogboxofthe

    ControlPanel,theWindowsComponentsaredisplayed. Highlighting

    ManagementandMonitoringToolsandthenselectingDetailsbringsupthe

    optiontocheckSimpleNetworkManagementProtocol(SNMP).

    AftertheSNMPserviceisinstalled,itsparameterscanbesetbyrightclickingon

    theSNMPserviceinServiceManagertoopenthePropertiespanel. Here,the

    communitynameofshowcaseandtrapdestinationcanbesetinthesecurityand

    trapstabs. TheseareshowninFigure2.

    December 2005 Page 8

  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    9/26

    Figure 2: Setting Traps and Security

    Loading Server Administrator

    ServerAdministratorisdistributedontheDellInstallationandServer

    ManagementCD.Documentationisavailableonlineat

    http://docs.us.dell.com/support/edocs/Software/svradmin/orontheProduct

    DocumentationCD. NotethattheCDhasaversionthatdenotesthereleaseof

    allOpenManageapplications(suchasversion4.5),butthatthespecificversionof

    ServerAdministrator

    (such

    as

    2.2)

    is

    on

    that

    CD.

    AlthoughmanuallyloadingServerAdministratoronasingleserveriscoveredin

    thispaper,itispossibletocompletelyscriptandautomatetheinstall. Formore

    informationsee

    http://support.dell.com/support/edocs/software/smsom/4.4/en/ug/index.htm.

    DoubleclickingtheInstallServerAdministratoricononasystemloadedwith

    theDellInstallationandServerManagementCD,orInsertingtheDell

    InstallationandServerManagementCD,willinvoketheServerAdministrator

    installationprogram.Theuserinputisasfollows:

    1. Atthe

    Prerequisite

    screen

    check

    that

    there

    are

    no

    critical

    errors

    or

    warnings

    andclickInstall,Modify,Repair,orRemoveServerAdministrator.2. AtthewelcomescreenclickNext>.

    3. ReadtheLicenseAgreement,thenhighlightIAcceptandclickNext>ifyouagreewithitsterms.

    December 2005 Page 9

    http://docs.us.dell.com/support/edocs/Software/svradmin/http://support.dell.com/support/edocs/software/smsom/4.4/en/ug/index.htmhttp://support.dell.com/support/edocs/software/smsom/4.4/en/ug/index.htmhttp://docs.us.dell.com/support/edocs/Software/svradmin/
  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    10/26

    4. HighlightCustomandclickNext>. TheCustomSetupwindowwillappear.

    Figure 3: Custom Setup Installation Options

    5. TheCustomSetupwindowwilldisplaythecomponentsthatwillbe

    installed. ClickNext>.

    6. ClickInstalltoinstalltheselectedOpenManagecomponents.

    7. ClickFinishandrebootifpromptedtodoso.

    December 2005 Page 10

  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    11/26

    Testing

    Afterthereboot,ServerAdministratorshouldbecheckedtoseethatitis

    operatingcorrectly. Thiscanbedoneinthefollowingsteps:

    1. LogintotheserverasAdministratororotheraccountwithadministrator

    membership.

    2. LaunchServerAdministratorfromthedesktopiconoropenabrowserand

    enterhttps://IP_or_SystemName:1311whereIP_or_SystemNameistheIP

    addressornetworknameofthesystem.

    Theaddresshttps://IP_or_SystemName:1311canbeusedfromanysystemwith

    networkaccesstotheservertoaccessServerAdministrator.

    3. LogintoServerAdministratorasAdministratororotheraccountwith

    administrativeprivileges.

    4. Select

    Systemin

    the

    left

    hand

    navigation

    tree.

    The

    status

    icons

    should

    all

    be

    greencheckstoindicateanerrorfreestatus

    Atthispoint,everythingshouldbeworkingcorrectlyontheDellsystem. A

    furthercheckwouldbetousesnmpwalk,whichispartofWin32toolsavailable

    athttp://www.wtcs.org/snmp4tpc/redirect.htm. AsshowninFigure4below,the

    commandsavesallavailableSNMPinformationavailableviacommunitystring

    showcaseonsystem192.168.30.4tothefiledellserver.txt. ProvidedthatDNSor

    WINSisproperlyconfiguredforthenewDellServersystem,itsnamecanbe

    usedinsteadoftheIPaddress.

    Snmpwalk192.168.30.4cshowcase>dellserver.txt

    Figure 4: Testing the PowerEdge Server with SNMPWALK

    Whenopeningdellserver.txtwithNotepad,thereshouldbeentrieswith10892in

    theOIDthatwerereturnedfromServerAdministrator. Specifically,

    1.3.6.1.4.1.674.10892.1.300.10.1.9.1willcontainthemodeloftheserver. Running

    thisfromthesystemhostingHPSIMtestsnetworkconnectivity,thatthe

    communitystringiscorrect,andthatServerAdministratorisprovidingthe

    expectedinformation.

    December 2005 Page 11

    https://ip_or_systemname:1311/https://ip_or_systemname:1311/http://www.wtcs.org/snmp4tpc/redirect.htmhttp://www.wtcs.org/snmp4tpc/redirect.htmhttps://ip_or_systemname:1311/https://ip_or_systemname:1311/
  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    12/26

    Sect ion 4

    Loading t he Del l MIBs

    DellMIBfilescanbefoundunderdownloadsonhttp://support.dell.com. After

    selectingthesystemtypeandoperatingsystem,DellMIBsforPowerEdgecan

    befoundunderSystemsManagementasfollows:

    Figure 5: Dell MIBs on http://support.dell.com

    Afterdownloadingandexecutingthepackage,theDellMIBsforPowerEdge

    serversareexpandedtoc:\DCMIBxx,wherexxrepresentstheversionofthe

    downloadedpackage. IngeneraltheversionoftheMIBpackagematchesthatof

    theassociatedOpenManagereleaseandtheseversionsshouldmatch. For

    example,becauseOpenManagerelease4.5wasusedforserverinstrumentation

    forthispaper,theDCMIB45MIBswerealsoused.

    ThetwoessentialMIBSare:

    10892,whichprovidesdetailedinformationaboutthesystemsmonitored

    byServerAdministratorinstrumentationsoftwaresuchas:systemtype,

    voltages,temps,etc. ItistheprimaryMIBforPowerEdgesystems.

    Detailedinformationcanbefoundat

    http://support.dell.com/support/edocs/software/svradmin/2.2/en/SNMP/

    index.htm.

    December 2005 Page 12

    http://support.dell.com/http://support.dell.com/support/edocs/software/svradmin/2.2/en/SNMP/index.htmhttp://support.dell.com/support/edocs/software/svradmin/2.2/en/SNMP/index.htmhttp://support.dell.com/support/edocs/software/svradmin/2.2/en/SNMP/index.htmhttp://support.dell.com/support/edocs/software/svradmin/2.2/en/SNMP/index.htmhttp://support.dell.com/
  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    13/26

    dcstorag,whichprovidesdetailedinformationaboutthestorage

    hardwarecomponentsandRAIDconfigurationsmonitoredbyServer

    AdministratorsStorageManagementService. Detailedinformationcan

    befoundat

    http://support.dell.com/support/edocs/software/svradmin/2.2/en/SNMP/

    snmpc25.htm#wp1194853

    AnumberofotherMIBsareincludedontheDCMIBxxdownloadpackage,

    butarebeyondthescopeofthispaper. AdescriptionofalltheMIBSand

    theiruseisdocumentedinAppendixA.

    Uploading the Dell MIBs

    UploadingtheMIBsissimplycopyingthemfromtheDCMIBxxfoldertothe

    \ProgramFiles\HP\SystemsInsightManager\mibsfolder

    1. Copy10892.mibanddcstorag.mibfromtheDCMIBxxfolderto\ProgramFiles\HP\SystemsInsightManager\mibs

    2. BecauseHPSIMgeneratesanerrorwhenaMIBhasafilenamethatcontains

    onlynumbers,rename\ProgramFiles\HP\SystemsInsightManager\mib\10892.mibtonew10892.mib,andforconsistencyalsorename

    dcstorag.mibtonewdcstorag.mib.

    dell10892.mibanddellarymgr.mib(usedwithDellsolderArrayManagerstorage

    managementtool)alreadyexistinthisfolderbecausetheycomewiththedefault

    installationofHPSIM. Itisrecommendedthatthesenamesbeavoidedforthenew

    filestoavoidconfusionwiththeHP andDellprovidedMIBs.

    Compiling the MIBs

    CompilingtheMIBscreatesanintermediate.cfgfilethatHPSIMcanlater

    register. TocompiletheDellMIBs:

    1. Openacommandwindow(cmd.exe).

    2. Usingthecdcommand,changeworkingdirectoryto\ProgramFiles\HP\SystemsInsightManager\mibs.

    3. Enterthecommandmcompilenew10892.mib. TheMIBshouldcompileandreturnthemessageMibCompilationcompletedsuccessfully.

    4. Enterthecommandmcompilenewdcstorag.mib. TheMIBshouldcompileand

    return

    the

    message

    Mib

    Compilation

    completed

    successfully.

    December 2005 Page 13

    http://support.dell.com/support/edocs/software/svradmin/2.2/en/SNMP/snmpc25.htm#wp1194853http://support.dell.com/support/edocs/software/svradmin/2.2/en/SNMP/snmpc25.htm#wp1194853http://support.dell.com/support/edocs/software/svradmin/2.2/en/SNMP/snmpc25.htm#wp1194853http://support.dell.com/support/edocs/software/svradmin/2.2/en/SNMP/snmpc25.htm#wp1194853
  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    14/26

    Registering the MIBs

    RegisteringMIBstoHPSIMistheprocessthatmapstheSNMPinformation

    receivedfromtheDellservertonumbersandcharacterstringsthatcanthenbe

    usedforidentificationandnotificationmessages. RegisterbothessentialMIBs

    asfollows:

    1. Enterthecommandmxmibanew10892.cfg. ThecfgfileshouldregisterandreturnthemessageCOMMANDCOMPLETEDSUCESSFULLY!.

    2. Enterthecommandmxmibanewdcstorag.mib. ThecfgfileshouldregisterandreturnthemessageCOMMANDCOMPLETEDSUCESSFULLY!.

    Figure 6: Running mcompile and mxmib

    December 2005 Page 14

  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    15/26

    Sect ion 5

    Syst em Type Manager

    WhenanewsystemisdetectedviaapingsweeporwhenreceivingaSNMP

    Trap,itisaddedtotheHPSIMdatabase. TheSystemTypeManagerthendoesa

    sequenceofqueriestothenewdevicetodetermineitsidentity. Thestepsbelow

    configureHPSIMtolookforspecificinformationintheDellprovidedMIBsto

    tellSystemTypeManagerthatthedevicefoundisaPowerEdgeserver. This

    onlyneedstobedoneonce,asallDellserversrunningServerAdministrator

    appearthesamewaytoHPSIM.

    ThestepsusedtoconfiguretheDeviceTypeManagertorecognizeaDellServer

    are:

    1. StartandlogintoHPSIM.

    2. SelectOptions >ManageSystemTypes.3. OntheProductmodelidentificationruleslist,scrolldownandselectDell

    ServerwiththeSNMPprotocol.4. Topreventconfusionandsimplifyadministration,clicktheDeletebuttonto

    deletetheexistingDellServerentry,andclickOKtoconfirm.

    5. ClicktheNewbutton. TheNewRulepanewillopenbelow.

    Whilevalues

    may

    be

    manually

    entered

    in

    the

    dialog

    boxes

    presented

    in

    the

    New

    Rule

    window,queryingaDellserverforthesevaluespreventstypographicalerrorsand

    providesverificationthatSNMPcommunicationisworkingproperly. Inthisvane,

    thequeryingtoolswithintheNewRulewindowwillbeused.

    6. BesideSystemobjectidentifierclicktheRetrievefromsystembutton.TheRetrievefromsystempanewillappearbelowthecurrentpane.

    7. IntheRetrievefromsystempanechangetheCommunitystringtoshowcase.

    8. EnterthehostnameorIPaddressofthetargetDellsystemintheTargethostnameorIPaddresstextbox.

    December 2005 Page 15

  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    16/26

    9. ClickGetResponse. Notethattheresponsevalueof1.3.6.1.4.1.311.1.1.3.1.2isdisplayedbelow. ThisisagenericWindowsresponsevalueandindicates

    thatSNMPcommunicationisworkingproperly.

    Figure 7: Retrieve OID from system

    10. Clickthe

    OK

    button

    to

    accept

    this

    value

    and

    return

    to

    the

    New

    rule

    pane.

    11. BesideMIBvariableobjectidentifierclicktheRetrievefromMIBbutton.TheRetrievefromMIBpanewillappearbelowthecurrentpane.

    12. BesideMIBdefinitionfilenamechoosenew10892.mibfromthelist.

    December 2005 Page 16

  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    17/26

    13. BesideMIBvariablenamechoosesystemManagementSoftwareName.

    Figure 8: Retrieve variable from MIB

    14. ClicktheOKbuttontoacceptthisvalueandreturntotheNewrulepane.

    15. Beside

    Objectvalue

    click

    the

    Retrievefrom

    System

    button.

    The

    Retrieve

    fromsystempanewillappearbelowthecurrentpane.

    16. ChangetheCommunitystringtoshowcase.

    December 2005 Page 17

  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    18/26

    17. ClicktheGetresponsebutton. NotethattheresponsevalueisServerAdministrator.

    Figure 9: Get response

    18.ClicktheOKbuttontoacceptthisvalueandreturntotheNewrulepane.

    19.BesideCompareruleselectstartswith.20.BesideProductmodelenterDellServer.

    December 2005 Page 18

  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    19/26

    21.LeavetheCustommanagementpagefieldblankandclicktheOKbutton.HPSIMisalreadyprogrammedtoredirectuserstoServerAdministratorforserver

    administrationonDellservers.

    Figure 10: Completed System Type Dialog

    December 2005 Page 19

  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    20/26

    Sect ion 6

    Disc over ing New Del l Ser vers

    NowthatthenewDellServerdevicetypehasbeenaddedtotheHPSIM

    database,HPSIMcanproperlydiscoverandidentifyDellPowerEdgeservers.

    ThefollowingisanexampleofperformingamanualdiscoveryoftheDellserver

    forthepurposeofprovidinganexampleforthispaper. Inyourenvironmentthe

    discoverysettingswillmostlikelybedifferent.

    Setting Global Protocol Settings

    EventhoughthecommunitystringofshowcasewassetinSNMPsetting

    previously,theappropriatedefaultcommunitystringmustbesetinHPSIMs

    GlobalProtocol

    Settings.

    To

    change

    this

    setting:

    1. ClickOptions >ProtocolSettings >GlobalProtocolSettings. TheGlobalProtocolSettingswindowwillappear.

    2. ScrolldowntotheDefaultSNMPsettingssectionandentershowcasebesideDefault1.

    Figure 11: Global Protocol Settings

    December 2005 Page 20

  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    21/26

    3. ClicktheOKbuttonatthebottomofthewindowtoacceptthischange.

    Manually Discovering a Dell Server1. ClickOptions >Discovery. TheDiscovery Automaticwindowwill

    appear.

    2. ClicktheManualtab.3. EntertheSystemnameorIPaddressoftheDellserverandclicktheAdd

    Systembutton.

    Figure 12: Manual Discovery

    4. ClickOKtoconfirmthedialogbox.

    5. Inthe

    SystemsandEventsframeonthelefthandsideofthescreen,clickAll

    Systems. TheDellservershouldnowbelistedintheAllSystemsframeontheright.

    December 2005 Page 21

  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    22/26

    Sect ion 7

    Test ing for Events

    OfalltheinformationintheMIBfiles,thetrapsorerrorindicationssentby

    ServerAdministratorareofprimaryinteresttoanadministrator.Thesearethe

    eventsthatcanbeusedtocauseanotificationsuchasanemailorpage.They

    havenameslikealertCoolingDeviceNormal withatextdescription,aseverity,

    andacategory.

    ThedefaultnotificationtaskswithinHPSIMarebasedonseveritywith

    informationaleventsbeingtrapsofinformationalseverityandimportant

    eventsbeingthosewithcritical,major,orminorseverities.

    Generate an Event

    AcompleteendtoendtestcanbeperformedbyusingOpenManageServer

    Administratortochangeathresholdsetting. Pullingapowercordorpower

    supplycanalsogenerateanerrorevent. Herearethestepsusedforthispaper:

    1. LogintoHPSystemsInsightManagerandclickonAllSystemsinthelefthandframe.

    2. ClickonthenameoftheserverintheSystemNamecolumnlinkoftheDellserverintheAllSystemsframe.

    3. Clickthe

    Tools&Linkstab.

    4. ClicktheServerAdministratorlink. ServerAdministratorwillappearinanewwindow.

    5. LogintoServerAdministratorusinganadministrativeaccount.

    6. ExpandMainSystemChassisinthelefthandnavigationtree.7. SelectVoltages.

    8. SelectBP3.3Vintheactionpane.9. SelectSettoValuesthenenteraMinimumWarningThresholdvaluethatis

    greater

    than

    the

    current

    Reading.

    For

    example,

    if

    the

    reading

    is

    currently

    3.231V,enteravalueof3.3.

    10. ClickApplyChanges.11. Thestatusfortheprobeshouldthenchangefromgreenchecktoayellow

    warningsymbol. ServerAdministratorwillnowalsogenerateawarning

    SNMPtrapandforwardittotheHPSIMserver.

    December 2005 Page 22

  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    23/26

    12.Tosetthevoltagewarningsbacktotheirdefaults,ensurethatSettoDefaultisselectedandclickApplyChanges. ServerAdministratorwillalsogeneratea

    normaltrapandforwardittotheHPSIMserver.

    13.InHPSIM,selectAllEventsfromthelefthandframeandnotetheeventsthathavebeengenerated.

    Figure 13: All Events

    December 2005 Page 23

  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    24/26

  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    25/26

    Appendix A

    Del l MIB s

    Essential Server MIBs

    MIBfile RegistrationResults Comments

    10892.mib OK Providesdetailedinformationaboutthe

    systemsmonitoredbyServerAdministrator

    instrumentationsoftware.The10892.mibisthe

    primaryMIBforPowerEdgesystems.

    dcstorag.mib OK Providesdetailedinformationaboutthe

    storagehardwarecomponentsandRAID

    configurationsmonitoredbyServer

    Administrator.

    Network Interface Adapters

    MIBfile RegistrationResults

    Comments

    adptinfo.mib

    Error

    defining

    object

    Providesinformation

    about

    Broadcom

    Gigabit

    networkadapters.

    baspCfg,

    baspStat,

    baspTrap.mib

    OK Collectively providedetailedinformation

    aboutBroadcomGigabitnetworkadapters.

    INTELLAN.mib Error

    defining

    object

    Providesdetailedinformationaboutthe

    Intel(TM)PRO100S,PRO1000xT,PRO100+

    DualPort,andPRO1000FNICadapters.

    December 2005 Page 25

  • 8/14/2019 Integrating PowerEdge Servers Into HPSIM50

    26/26

    Other Adapters, Devices, and Software

    MIBfile RegistrationResults

    Comments

    DcAsfSrv.mib OK SpecifiesformattingforDellserverPlatform

    Event

    Traps

    generated

    by

    the

    Baseboard

    ManagementController

    ITassist.mib OK ProvidesdefinitionsfortrapssentbytheIT

    Assistantmanagementapplication.

    rac_host.mib OK Providesdetailedinformationaboutthe

    componentsmonitoredbytheremoteaccess

    outofbandsoftwareagent.

    Legacy MIBs

    ThefollowingMIBSarefromearlierversionsofOpenManageandwouldnotbe

    neededifthecurrentversionofServerAdministratorisusedthroughoutthe

    environment.

    MIBfile RegistrationResults

    Comments

    arymgr.mib OK Providesdetailedinformationaboutstorage

    hardwarecomponentsandRAIDconfigurations

    monitoredbytheArrayManageragent.

    dcs3rmt.mib OK Providesdetailedinformationabouttheremote

    accesscomponents

    monitored

    by

    the

    Server

    AdministratorRemoteAccessService.

    dellcm.mib OK Providesdetailedinformationaboutthechange

    managementdatamonitoredbytheServer

    AdministratorUpdateService.

    THISWHITEPAPERISFORINFORMATIONALPURPOSESONLY,ANDMAYCONTAINTYPOGRAPHICAL

    ERRORSANDTECHNICALINACCURACIES.THECONTENTISPROVIDEDASIS,WITHOUTEXPRESSOR

    IMPLIEDWARRANTIES

    OF

    ANY

    KIND.

    Dell,OpenManage,PowerEdgeandOptiPlexaretrademarksofDellInc. MicrosoftandWindowsareregistered

    trademarksofMicrosoftCorporation. NetWareisaregisteredtrademarkofNovell.Linuxisaregisteredtrademarkof

    LinusTorvalds.InsightManagerisatrademarkofHewlett Packard.FirefoxisatrademarkoftheMozillaFoundation.

    Othertrademarksandtradenamesmaybeusedinthisdocumenttorefertoeithertheentitiesclaimingthemarksand

    namesortheirproducts. Delldisclaimsproprietaryinterestinthemarksandnamesofothers.

    Copyright2005DellInc. Allrightsreserved. Reproductioninanymannerwhatsoeverwithouttheexpresswritten

    permissionofDellInc. isstrictlyforbidden. Formoreinformation,contactDell.

    Informationinthisdocumentissubjecttochangewithoutnotice.