Intelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it.

Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

Intelligent GSM

Auto-dial Alarm System

User’s Manual

Profile

For a better understanding of this product, please read this user

manual thoroughly before using it.

Page 2: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

2

CONTENTS [Function Instruction]

[Control Panel Introduction]

[Door Contact]

[PIR Detector]

[Initialization]

[Voice Recording]

[Monitor Panel Power]

[Connect Outdoor Siren]

[Monitor GSM Signal]

[Function Settings]

1. Pair Remote Controls

2. Pair Wireless Sensors

3. Command Chart

[Operation Instructions]

1. Arm/ disarm Operation

2. Emergency Help

3. Alarming

4. Remote Control

[Technical Parameters]

[Components List]

[Care and Maintenance]

Page 3: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

3

[Function Instruction] � 96 wireless and 3 wired defense zones; each could be programmed

independently and the alarm SMS is editable;

� Maximum 99 remote controls; both IC 2262 and EV 1527 compatible;

� Control panel tamper alarm;

� Sensor low-power alarm, and sensor tamper alarm; it will send SMS when

alarming;

� English voice prompt for all operations;

� 5 groups alarm phone number and 5 SMS number;

� One relay link to arm or disarm; one relay support remote control;

� External power failure/ recovery alert;

� System settings could be finished by SMS or call DTMF;

� Built-in RF transmitter: easy to set with wireless sirens;

� 10-second voice recording: will be heard when receiving alarm call;

[Control Panel Introduction] In order to make the main panel get the wireless signal well for all wireless accessories, please put the alarm host at the central place of your defense area. Make sure it’s away from large metal objects and household appliances which may cause high frequency interference, as well as barriers such as reinforced concrete wall or fire door, etc.

Page 4: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

4

LED indicator:

LED LED Status System working status

POWER OFF No power

ON (red) Power supply is normal

Flashing slowly in red Powered by built-in battery

STATUS Flash per second

(orange)

Checking GSM network and

SIM card

ON (orange) GSM network or SIM card is

abnormal

ON (green) Disarm status

Flash per second

(green)

Away arm status

Flash every 2 seconds Home arm status

ON (red) Alarming

Flash per second (red) Delay alarming

Flash quickly in red Under remote control

Page 5: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

5

MON/SPK ON Monitor/ intercom status

REC ON Recording

Flash quickly Record replaying

RF ON Remote controller/ wireless

sensor paring

ZONE ON Wireless sensor paring

OUT2 OFF Relay P2 is disconnected

ON (red) Relay P2 is connected

OUT1 OFF Relay P1 is disconnected

ON (red) Relay P1 is connected

Alarm panel built-in buzzer:

Buzzer Status System working status

Short beep Paring completed

One short beep System arm

Long beep for

500ms

GSM network checked successful; receiving correct

SMS

Two short beeps System disarm

Four short beeps Repeat paring

Voice Prompt Correspondent Operation

system armed Away arm/ home arm

system disarmed Disarm

coding completed Remote controls or wireless sensors paring

please enter password Prompt for remote control operation

Page 6: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

6

wrong password When you input a wrong password

delete completed Deletion is successful.

setting completed The setting is correct.

please enter instruction After correct password

Back panel:

Wired terminal block:

Page 7: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

7

1 SPK+ Positive of siren (red cable)

2 SPK- Negative of siren (black cable)

3 LB+ Positive of speaker (red cable)

4 LB- Negative of speaker (black cable)

5 P1

This switch will be connected when arming; and

disconnected when disarming. 6

7 P2

Use command to set it connected/ disconnected.

Please refer to the “command chart” part on page 9 8

9 Z1 Wired sensor 1 (zone number: 97)

10 Z2 Wired sensor 2 (zone number: 98)

11 Z3 Wired sensor 3 (zone number: 99)

12 GND Ground

Page 8: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

8

Note:

1. Please pay attention to the siren connection. Positive side to “SPK+”

and negative to “SPK-”. Do not mix the two cables together when

connecting. Otherwise, it will damage the transistor in the main panel.

2. Wired sensor connection: connect one cable of the wired sensor to GND

and the other to “Z1, Z2 or Z3”.

3. Relay P1 will be connected when system armed, and the OUT1 indicator

will be on. It will be disconnected when system disarmed, and the

OUT1 indicator will be off.

[Door Contact] Door sensors are used for detecting the status of open and close of windows

and doors. It will detect it and send the signal to main panel.

� Tear apart the double-side adhesive tape on the magnet and the

transmitter. Then adhere them to the appropriate position.

� Magnet should

be near to the

side of

transmitter with

indicator. The

two should

align with each

other and the

distance should not exceed 10mm.

� Please plug out the antenna for better signal.

� If the low-power indicator is on, please change the battery.

Page 9: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

9

[PIR Detector] PIR detectors are used to detect the movement within a certain range.

� Fix the

adjustment

bracket on the

wall with the

provided screws

and attach the

detector to the bracket. It is recommended to mount it at a height of

2-2.2m above the floor.

� Effect of the PIR detection is best when the detection direction is in 90°

angle with the walking direction of the intruder. Choose the most

suitable installation place and angle according to actual situation and

taking the following installation diagram as reference to ensure the

detection effect is best.

� Please do not fix it under direct sunlight or other strong lights and also

keep it away from places with frequent strong air stream.

� If the low-power indicator is on, please change the battery.

[Initialization] -Please insert SIM card. Make sure the card has enough balance to make call and send sms. -Connect the siren, wired sensors, or relay -Plug in power adaptor, and turn on the power switch. The POWER indicator will be on and the STATUS LED flashes in orange. The system starts checking the GSM network.

Page 10: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

10

-After checking the SIM card and GSM network normally, the panel will make a long beep and the STATUS LED will turn green. At this time, the system enters into disarm status. If the GSM network is not checked successfully, the STATUS LED will be in orange. -Pair the extra wireless sensors and remote controllers that are not included in the standard pack, and make function settings. [Voice Recording] In disarm status, press the “REC” button at the back side of the panel. REC indicator at the front panel will turn on. You can start recording now. 10 seconds later, it will exit recording and play the recorded voice automatically. At the same time, the REC light will flash quickly. After playing record, you can press REC button again to re-record. [Monitor Panel Power] This system has the function of SMS alert for external power failure and recovery. When the external power is cut off, the built-in LI battery will keep the system working. The SMS content for external power disconnection: Power charger off; power recovery: Power charger on. [Connect Outdoor Siren] The alarm panel has built-in transmitter which can work together with wireless sirens. You need not to connect external transmitters. Setting method: -turn on the Wireless Transmission function (check the command chart on page 12); -make the siren into coding status (check the siren manual); -make the control panel into disarm status, and then press the SOS button on the remote control. The panel will send signal to the siren. The siren will make a beep sound after successfully receiving which means setting completed. -siren: exit coding status.

Page 11: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

11

[Monitor GSM Signal] This system has the function of alert for bad GSM signal. When the GSM signal is less than 10, the panel will send SMS “bad GSM signal”. And when the signal is equal to 0, the siren will start ringing for 5 minutes. The factory default for this function is off, you can turn it on by “password#17#0#” (check the command chart on page 10).

[Function Settings] 1. Pair Remote Controls Extra remote controls have to be set with the control panel in order to perform normally. The one in the standard package has been paired. This alarm system supports maximum 99 remote controls. Find the RF button next to the SIM card slot. Press it during disarm status. The RF LED turns on and then press any button on the remote control. You will hear a beep sound which means setting is successful. Then press the RF button again to save the setting. If the panel makes four short beeps, it means the remote control has been paired before or the remote control number exceeds 99. 2. Pair Wireless Sensors Wireless detectors have to be set with the control panel in order to trigger it alarm. The wireless PIR sensor and door contact in the standard package have been paired. This alarm system has 96 wireless defense zones. Press the RF button twice during disarm status. The RF LED and ZONE LED both turn on. At this time, trigger the sensor you want to set. You will hear a beep sound which means setting is successful. Then press the RF button again to save the setting. If the panel makes four short beeps, it means the sensor has been paired before or the sensor number exceeds 96. The serial number of the remote controls and sensors is defined by the setting sequence. That means, the first remote control set is NO.1, and the third

Page 12: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

12

sensor set is in NO.3 zone. 3. Command Chart For all the settings of this alarm system, you can finish by sending SMS or making call to the control panel. The SMS content: password#command Default password: 123456 Alarm receiving: after receiving alarm call, you can do the settings directly without inputting password. Command Function Setting

method Alarm receiving

1#1# Away arm Call or SMS YES

1#2# Home arm

1#0# Disarm

11#1# Siren on when alarm (default) NO

11#0# Siren off when alarm

12#1# Send SMS when alarm (default)

12#0# No SMS when alarm

15#1# Make call when alarm (default)

15#0# No call when alarm

17#1# GSM signal monitor activated YES 17#0# GSM signal monitor deactivated

(default) 3#1# Turn on the siren immediately Call 3#0# Turn off the siren 30## Inquire the system status SMS NO 31#xxxxxx#

Change password (default: 123456)

Call or SMS

32## Inquire GSM signal (0~31) SMS 33## Inquire IMEI code (15-digit)

Page 13: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

13

35#xx# Set the siren ring time (default: 3min; xx: 0~15min)

Call or SMS

36#0# Delete all settings except sensors and remote controls

36#1# Delete sensors 36#2# Delete remote controls

38#AA#B#C#

Defense zone type setting. AA: defense zone number (01~99); B: zone type (1: 24 hours; 2: real-time; 3: delay; 4: bypass.); C: home arm setting (0: deactivate, 1: activate); after activation, in home arm status, when the sensor in this zone is triggered, it will trigger alarm. Default: all defense zones are real time, home arm deactivated. Call and SMS setting both ok.

39#AA#xx#

Alarm SMS setting. AA: defense zone number (01~99); xx: SMS content (maximum 16 characters)

SMS

4#0# Turn off listen-in Call YES 4#1# Turn on listen-in 40#1# Turn on Wireless Transmission Call or SMS NO 40#0# Turn off Wireless Transmission

(default)

41#xxxx# Wireless Siren Coding Encryption (xxxx: 0000~9999; default: FFFF)

42#1# Turn on SMS reply function (default)

42#0# Turn off SMS reply function 43#1# Turn on arm/disarm SMS

Page 14: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

14

notification 43#0# Turn off arm/disarm SMS

notification (default) 44#xx# Arm/ exit delay time setting

(00~99seconds, default: 0) 45#xx# Disarm/ entry delay time setting

(00~99seconds, default: 0)

46#1# Turn on arm/ disarm voice prompt

46#0# Turn off arm/ disarm voice prompt (default)

47#1# Turn on all voice prompt 47#0# Turn off all voice prompt

(default) 48#1# Turn on the panel buzzer

(default) 48#0# Turn off the panel buzzer

50## Inquire alarm phone numbers SMS 51#X# Set alarm phone number (1st) X:

maximum 15 numbers Call or SMS

52#X# Set alarm phone number (2nd) 53#X# Set alarm phone number (3rd) 54#X# Set alarm phone number (4th) 55#X# Set alarm phone number (5th)

51## Delete alarm phone number (1st) 52## Delete alarm phone number

(2nd) 53## Delete alarm phone number (3rd) 54## Delete alarm phone number (4th) 55## Delete alarm phone number (5th) 60## Inquire alarm SMS numbers SMS

61#X# Set alarm SMS number (1st) X: maximum 15 numbers

Call or SMS

Page 15: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

15

62#X# Set alarm SMS number (2nd) 63#X# Set alarm SMS number (3rd) 64#X# Set alarm SMS number (4th) 65#X# Set alarm SMS number (5th)

61## Delete alarm phone number (1st) 62## Delete alarm phone number

(2nd) 63## Delete alarm phone number (3rd) 64## Delete alarm phone number (4th) 65## Delete alarm phone number (5th)

92#1# Turn on the siren for arm/disarm operation

92#0# Turn off the siren for arm/disarm operation (default)

93#1# Turn on two-way intercom Call YES

93#0# Turn off two-way intercom (default)

94#1# Connect relay P2 Call or SMS

94#0# Disconnect relay P2

95#1# Set zone 97 as NO NO

95#0# Set zone 97 as NC (default)

96#1# Set zone 98 as NO

96#0# Set zone 98 as NC (default)

97#1# Set zone 99 as NO

97#0# Set zone 99 as NC (default)

951753082

46##

Factory reset (all settings are deleted and all the sensors and remote controls are deleted)

98#1# Turn on tamper alarm function

Page 16: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

16

98#0# Turn off tamper alarm function (default)

99## Delete the common SMS content (check explanation in “Note”)

99#xx#

Set common SMS. xx: SMS content (maximum 30 characters)

SMS

Note: * Common SMS content: after this setting, all the alarm SMS will start with this content you set. For example, “99#Tom#”, you may receive alarm message like this “Tom 1 Zone Alarm!”. System default for this is empty. *Factory reset: you can also do it like this: keep pressing the “REC” button and “RF” button at the same time for 5 seconds. You will hear 6 beeps. * For the above settings, if you set by SMS, you will receive a message from the system for confirmation. This function could be set as off if you do not need the confirmation SMS (42#0#). But for the following settings, SMS reply could not be set off: 1. Inquiry setting: Inquire the system status, inquire GSM signal, inquire

IMEI, alarm telephone number and SMS number. 2. Arm/ disarm the system by SMS. * SMS setting is easily affected by GSM network which may cause delay, so it’s recommended to do the settings by call. * Please make your mobile phone as English version when you send SMS. Please check all the SMS reply in the following table.

Command SMS Reply

Page 17: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

17

1#1# System armed

1#2# Home armed

1#0# System disarmed

11#1# Siren when alarming enabled

11#0# Siren when alarming disabled

12#1# Alarm SMS Enabled

12#0# Alarm SMS Disabled

15#1# Alarm Phone Call Enabled

15#0# Alarm Phone Call Disabled

17#1# GSM Signal Monitor Enabled

17#0# GSM Signal Monitor Disabled

30##

System armed

Home armed

System disarmed

31#password# Password set to: 6-digit numbers

32## GSM Signal: (01~31)

33## IMEI: (15-digit)

35#xx# Siren ringing time set to: xx minutes

36#0# All settings except coding information

deleted

36#1# All defense zone deleted

36#2# All remote controls deleted

Page 18: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

18

38#AA#B#C#

AA: 01-99; B: 1-4

1: 24 hours defense

zone; 2: real-time

defense zone; 3: delay

defense zone; 4: bypass

defense zone

C: 0-1

0: invalid; 1: valid

For example:

123456#08#3#0#

SMS Reply:

Zone: 08

Defense Zone Type: delay defense zone

Home Arm Defense Zone: invalid

39#AA#xx#

AA: 01-99

xx: SMS content

For example:

123456#39#08#gas leakage#

SMS Reply:

User defined sms content zone: 08 gas

leakage

40#1# Wireless Transmission Control: ON

40#0# Wireless Transmission Control: OFF

41#XXXX# Wireless Siren Coding Encryption: xxxx

42#1# SMS reply: ON

42#0# SMS reply: OFF

43#1# SMS Notification for Arm/disarm: ON

43#0# SMS Notification for Arm/disarm: OFF

44#XX# Arm Delay Time: xx seconds

45#XX# Alarm Delay Time: xx seconds

46#1# Arm/Disarm Voice Guide Prompt: ON

Page 19: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

19

46#0# Arm/Disarm Voice Guide Prompt: OFF

47#1# Voice guide: ON

47#0# Voice guide: OFF

48#1# Voice of Buzz: ON

48#0# Voice of Buzz: OFF

50##

No phone number;

Or

Call phone number 1: xx

Call phone number 2: xx

Call phone number 3: xx

Call phone number 4: xx

Call phone number 5: xx

51#xxxxx# Call phone number 1: xxxxx

52#xxxxx# Call phone number 2: xxxxx

53#xxxxx# Call phone number 3: xxxxx

54#xxxxx# Call phone number 4: xxxxx

55#xxxxx# Call phone number 5: xxxxx

51## Call phone number 1 deleted

52## Call phone number 2 deleted

53## Call phone number 3 deleted

54## Call phone number 4 deleted

55## Call phone number 5 deleted

60##

No SMS number;

Or

SMS phone number 1: xx

Page 20: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

20

SMS phone number 2: xx

SMS phone number 3: xx

SMS phone number 4: xx

SMS phone number 5: xx

61#xxxxx# SMS phone number 1: xxxxx

62#xxxxx# SMS phone number 2: xxxxx

63#xxxxx# SMS phone number 3: xxxxx

64#xxxxx# SMS phone number 4: xxxxx

65#xxxxx# SMS phone number 5: xxxxx

61## SMS phone number 1 deleted

62## SMS phone number 2 deleted

63## SMS phone number 3 deleted

64## SMS phone number 4 deleted

65## SMS phone number 5 deleted

92#1# Enable the external siren sound when use

remote controller to Arm/Disarm

92#0# Disable the external siren sound when use

remote controller to Arm/Disarm

94#1# Relay P2: ON

94#0# Relay P2: OFF

95#1# Z1 97 defense zone set to: NO

95#0# Z1 97 defense zone set to: NC

96#1# Z1 98 defense zone set to: NO

96#0# Z1 98 defense zone set to: NC

97#1# Z1 99 defense zone set to: NO

Page 21: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

21

SMS content for alarming:

Alarm type SMS content

Tamper alarm The tamper alarm button on the back side of the panel is bounced up (not in setting status)

System Tamper Alarm!

Emergency button on the remote control

Remote X SOS Alarm! (X is the remote control serial number 1~99)

Wireless and wired sensors

For “real-time, 24 hours or delay” defense zone: X zone Alarm! (X is the defense zone serial number 1~96) For “close” defense zone, trigger the sensor, it will not make alarm.

Sensor low power (note: the sensor should have low power alarm function)

X zone Low Power! (X is the defense zone number of the sensor 1~96)

Sensor tamper alarm (note: the sensor should have tamper alarm function)

X zone Tamper Alarm! (X is the defense zone number of the sensor 1~96)

97#0# Z1 99 defense zone set to: NC

95175308246## System reset

98#1# Alarm panel tamper switch enabled

98#0# Alarm panel tamper switch disabled

99## Common SMS content deleted

99#xxxxxx# Common SMS content set to: xxxxxx

Page 22: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

22

[Operation Instructions] 1. Arm/ disarm Operation Set the system into arm status means making it work (guarding your house or place you install). When there is an alarm triggered, you will receive alarm call and sms, at the same time the siren will ring. You can disarm it to stop alarming. Away Arm: all detectors keep working. STATUS indicator flashes slowly in green. a. Press [OUT ARM] button on the remote controls b. Send SMS to the alarm panel: password#1#1# c. Call the alarm panel: password, 1#1# Home Arm: part of the detectors keep working. How to set the detectors working or not, please check the [command chart] “Defense zone type setting” on page 11. STATUS indicator flashes quickly in green. a. Press [HOME ARM] button on the remote controls b. Send SMS to the alarm panel: password#1#2# c. Call the alarm panel: password, 1#2# Disarm: STATUS LED keeps on in green a. Press [DISARM] button on the remote controls b. Send SMS to the alarm panel: password#1#0# c. Call the alarm panel: password, 1#0#

2. Emergency Help Press SOS button on the remote control. No matter the system is in arm or disarm status, it will make alarm immediately. 3. Alarming Answer Alarm Call When the main panel sounds the alarm, it will dial the preset numbers. If no one answers the call, the system will call the next user number automatically. The system will call each preset numbers for 3 times in order. If you answer the call, you will hear the pre-record voice for 3 times. You can

Page 23: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

23

set system via your phone. If you hang-up directly without answering the call, the system will keep calling the next number. Press [1#1#]: System stops alarming and Away Arm; it stops calling users. Press [1#2#]: System stops alarming and Home Arm; it stops calling users. Press [1#0#]: System stops alarming and Disarm; it stops calling users. Press [4#1#]: Starts listen-in. Press [93#1#]: Starts two-way intercom. Press [94#1#]: Turn relay on. Press [94#0#]: Turn relay off. All the settings in the command chart that support “call setting” could be done after you receive alarm call. 4. Remote Control Dial the number associated to the control panel by phone (mobile phone), and after one ringing cycle, you can hear a voice prompt “Please enter password”. Input the password (default: 123456). If there’s no operation within 60 seconds, the call will be hung up directly. If the password is wrong, you will hear a prompt voice “error, please re-enter”. If the password is right, you will hear “ok, please enter instruction”. Now you can do all the settings in the command chart that support “call setting”. [Note] If the voice prompt is turned off, you will hear beeps for operation. A long beep after the call gets through, you can start to input password. For each pressing, there will be a short beep sound. If there’s no beep sound, please re-enter. And there will be four short beeps for wrong operation. [Technical Parameters] Power supply: AC=100V~250V, DC=12V, 1.2A Built-in battery: 7.4V, 1000mA LI battery (keep working for about 8hrs after external power failure)

Page 24: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

24

Standby current: 65mA GSM band: 850/900/1800/1900MHz Wireless frequency: 433MHz ±0.5MHz Wireless receiving sensitivity: 5mV/m Wireless modulation: ASK Anti-interference: 1V/m (frequency range: 20~1000 MHz) Wireless sensors: 96pcs Remote controllers: 99pcs Working temperature: 0℃~+40℃ Humidity: ≤90% (no fog)

[Components List] Control panel 1 pc,

Remote controls 2 pcs,

Wired mini siren 1 pc,

PIR sensor 1 pc,

Door contact 1 pc,

Power adapter 1 pc,

User manual 1 pc.

[Care and Maintenance] The alarm system has excellent design and uses advanced technologies. It

shall be used with care. The following suggestions are required to maintain

your obligations under the warranty terms, and for prolonging the service life

of the system.

� Place the control panel and all parts and accessories out of children’s

reach.

Page 25: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

25

� Keep the alarm system dry. Rain, humidity and various fluids or

moisture all will corrupt the electronic circuit.

� Do not use or place the alarm system in dirty locations, otherwise the

electronic elements will be damaged.

� Do no place the system in excessively hot locations. High temperature

will shorten the service life of electronic equipment, damage batteries, deform

or even melt some plastic parts.

� Do not place the system in excessively cold locations. Otherwise

condensation many occur and damage the circuit board of the alarm system.

� It is recommended that you check and test the alarm system

periodically:

Check the main unit every three months:

1. Whether it can arm/disarm normally;

2. Whether it can dial the number for alarm normally;

3. Whether it can receive wireless detectors’ signal normally;

4. Whether the back-up battery can work normally.

Check the wireless detectors once a month:

1. Trigger wireless detectors to see if system can alarm normally;

2. Check all detectors’ batteries to see if it’s in low voltage;

3. Check whether wireless detectors can send signal to the main unit

normally.

Check the SIM card:

1. Check the use of SIM card, such as network signal, balance, etc.

2. Make sure the PIN code verification of the SIM card is closed.

3. Please keep the password and SIM card number safe, in case that other

people remote control the system illegally.

Page 26: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

26

� Since the alarm system is continuously in operation or standby mode,

the supply adaptor of the control panel shall be connected to a safe and

reliable socket.

� Do not place the system near your bedroom or office table, because the

siren will make high-loudness sound in the case of alarm, which may

adversely affect your rest or work.

� If the alarm system will not be used for a long time, please disconnect

the system from the power supply.

� Please do not disassemble, repair or alter the products without

permission, or it may cause accidents and faults.

� Do not drop this product on the ground or on hard objects, as it may lead

to massive impact to cause faults and damages.

� Without approval and consent of relevant authorities, please do not set

“112”, “911” or the alarm phone number of police station for this main unit.

Please read the suggestions above carefully and follow the instructions herein.

If any of the equipment does not work properly, please send it to the dealer or

authorized service point for repair. We will try our best to solve the problem

for you as soon as possible.

The following accessories are optional:

Page 27: Intelligent GSM Auto-dial Alarm System - QualiCamIntelligent GSM Auto-dial Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual

27

Optional sensors/detectors are packed separately. You can choose according to

your specific requirements.