Internal Partition Double SkinDetails
Unit E, Halesfield 10, Telford, Shropshire TF7 4QP England T: 01952 581 150 F: 01952 585 147 E: [email protected] www.librasystemsuk.com
Contents
Metal Stud Partition System (Internal Partitions Double Skin)
ML/TYP/020ML/TYP/021ML/TYP/022 ML/TYP/023 ML/TYP/024 ML/TYP/025 ML/TYP/026 ML/TYP/027 ML/TYP/028
15 ‐ 25mm / non fire rated deflection head
15 ‐ 25mm / 30 or 60 minute deflection head 50mm / 60 minute deflection headhead base detail
internal and external corner detail
abutment detail
T Junction
horizontal joint
light / medium door opening
light / medium door opening ‐ section AA
30 or 60 minute deflection head with core board 90 or 120 minute deflection head
ML/TYP/029ML/TYP/030ML/TYP/031
standard internal partition
15 ‐ 25mm / non fire rated deflection head
mastic seals
Libra DC channel fixed at
600mm centres
flat plate option 2
max 150mm 15 ‐ 25mm
uppermost board fixing
flat plate option 1
lining boards (and Plywood
where applicable) as per
specification
perimeter to partition framing
with drywall screws at maximum
300mm centres
Libra C or I studs as per
specification
Notes: This drawing should be read in conjunction with the relevant sections of the manufacturers current product literature
we would draw your attention to the Construction (Design and Management) Regulations 1994 and the Approved Code of
Practice which detail the legal duties of clients, client's agents designers and contractors involved in construction projects. for discussion purposes only / do not scale
project:
Typical Detail
initials: date: drg no:
ML 21/5/2017 ML/TYP/020
15 ‐ 25mm
lining boards fixed to their entire
standard internal partition
15 ‐ 25mm / 30 or 60 minute deflection head
mastic seals
2 x 15mm plasterboard dropped
soffits
Libra DC channel fixed at
600mm centres
max 150mm flat plate option 2
15 ‐ 25mm
flat plate option 1
lining boards (and Plywood
where applicable) as per
specification
perimeter to partition framing
with drywall screws at maximum
300mm centres
Libra C or I studs as per
specification
Notes: This drawing should be read in conjunction with the relevant sections of the manufacturers current product literature
we would draw your attention to the Construction (Design and Management) Regulations 1994 and the Approved Code of
Practice which detail the legal duties of clients, client's agents designers and contractors involved in construction projects. for discussion purposes only / do not scale
project:
Typical Detail
initials: date: drg no:
ML 21/5/2107 ML/TYP/021
firestrip or intumescent mastic
15 ‐ 25mm
15 ‐ 25mm
uppermost board fixing
lining boards fixed to their entire
dropped soffit formed from
minimum 50mm deep timber50mm
standard internal partition
50mm deflection head (downward only)
60 minute FR
firestrip or intumescent mastic mastic seals
we would draw your attention to the Construction (Design and Management) Regulations 1994 and the Approved Code of
Libra EDC channel fixed at
600mm centres
50mm
max 150mm
flat plate option 2
uppermost board fixing
50mm
flat plate option 1
lining boards (and Plywood
where applicable) as per
specificationlining boards fixed to their entire
perimeter to partition framing
with drywall screws at maximum
300mm centres
Libra C or I studs as per
specification
Notes: This drawing should be read in conjunction with the relevant sections of the manufacturers current product literature
ML 15/03/2017 ML/TYP/022
Practice which detail the legal duties of clients, client's agents designers and contractors involved in construction projects. for discussion purposes only / do not scale
project:
Libra Typical Detail
initials: date: drg no:
standard internal partition
base detail
lining boards fixed to their entire
perimeter to partition framing
with drywall screws at maximum
300mm centres
Libra C or I studs as per
specification
lining boards (and Plywood
where applicable) as per
specification
Libra standard channel fixed to
floor at 600mm centres
gaps over 5mm to be bulk filled
with a gypsum based product
Notes: This drawing should be read in conjunction with the relevant sections of the manufacturers current product literature
we would draw your attention to the Construction (Design and Management) Regulations 1994 and the Approved Code of
Practice which detail the legal duties of clients, client's agents designers and contractors involved in construction projects. for discussion purposes only / do not scale
project:
Typical Detail
initials: date: drg no:
ML 21/5/2107 ML/TYP/023
mastic seals
standard internal partition
internal and external corner detail
Libra C studs fixed at
600mm centres
lining boards (and Plywood
where applicable) as per
specification
lining boards fixed to their entire
perimeter to partition framing
with drywall screws at maximum
300mm centres
Notes: This drawing should be read in conjunction with the relevant sections of the manufacturers current product literature
we would draw your attention to the Construction (Design and Management) Regulations 1994 and the Approved Code of
Practice which detail the legal duties of clients, client's agents designers and contractors involved in construction projects. for discussion purposes only / do not scale
project:
Typical Detail
initials: date: drg no:
ML 21/5/2017 ML/TYP/024
standard internal partition
abutment detail
Libra C studs fixed at
600mm centres
mastic seals
where applicable) as per
specification
lining boards fixed to their entire
perimeter to partition framing
with drywall screws at maximum
300mm centres
Notes: This drawing should be read in conjunction with the relevant sections of the manufacturers current product literature
we would draw your attention to the Construction (Design and Management) Regulations 1994 and the Approved Code of
Practice which detail the legal duties of clients, client's agents designers and contractors involved in construction projects. for discussion purposes only / do not scale
project:
Typical Detail
initials: date: drg no:
ML 21/5/2017 ML/TYP/025
lining boards (and Plywood
standard internal partition
T Junction
Libra C studs as per
specification, fixed at
600mm centres
mastic seals
lining boards (and Plywood
where applicable) as per
specification
lining boards fixed to their entire
perimeter to partition framing
with drywall screws at maximum
300mm centres
Notes: This drawing should be read in conjunction with the relevant sections of the manufacturers current product literature
we would draw your attention to the Construction (Design and Management) Regulations 1994 and the Approved Code of
Practice which detail the legal duties of clients, client's agents designers and contractors involved in construction projects. for discussion purposes only / do not scale
project:
Typical Detail
initials: date: drg no:
ML 21/5/2107 ML/TYP/026
standard internal partition
horizontal joint
horizontal joint ‐ horizontal joint ‐
option 1 option 2
Libra flat plate twice fixed to Libra flat plate between
stud board layers
lining boards fixed to their entire
perimeter to partition framing
with drywall screws at maximum
300mm centres
lining boards (and Plywood
where applicable) as per
specification
Notes: This drawing should be read in conjunction with the relevant sections of the manufacturers current product literature
we would draw your attention to the Construction (Design and Management) Regulations 1994 and the Approved Code of
Practice which detail the legal duties of clients, client's agents designers and contractors involved in construction projects. for discussion purposes only / do not scale
project:
Typical Detail
initials: date: drg no:
ML 21/5/2017 ML/TYP/027
Libra C or I studs as per
specification
standard internal partition
light / medium door opening 600mm centres
600mm centres maintained over opening
no fixings into deflection head
Libra flat plate installed below
deflection head
Libra C studs as per
specification
A A
perimeter to partition framing
with drywall screws at maximum
300mm centres
Libra standard
channels fixed to
floor at 600mm
centres
Notes: This drawing should be read in conjunction with the relevant sections of the manufacturers current product literature
we would draw your attention to the Construction (Design and Management) Regulations 1994 and the Approved Code of
Practice which detail the legal duties of clients, client's agents designers and contractors involved in construction projects. for discussion purposes only / do not scale
project:
Typical Detail
initials: date: drg no:
ML 21/5/2107 ML/TYP/028
deflection head detail fixed to soffit at
150mm
lining boards fixed to their entire
standard internal partition
light / medium door opening ‐ section AA
Libra C stud with softwood
timber insert to provide fixing
ground for the door lining
lining boards (and Plywood
where applicable) as per
specification
lining boards fixed to their entire
perimeter to partition framing
with drywall screws at maximum
300mm centres
Notes: This drawing should be read in conjunction with the relevant sections of the manufacturers current product literature
we would draw your attention to the Construction (Design and Management) Regulations 1994 and the Approved Code of
Practice which detail the legal duties of clients, client's agents designers and contractors involved in construction projects. for discussion purposes only / do not scale
project:
Typical Detail
initials: date: drg no:
ML 21/5/2017 ML/TYP/029
Libra C studs fixed at
600mm centres
ML 10/11/2017 ML/TYP/030
LibraCorIstudsasperspecification
Practicewhichdetailthelegaldutiesofclients,client'sagentsdesignersandcontractorsinvolvedinconstructionprojects. fordiscussionpurposesonly/donotscale
project:
LibraTypicalDetail
initials: date: drgno:
flatplateoption1
liningboards(andPlywoodwhereapplicable)asperspecificationliningboardsfixedtotheirentire
perimetertopartitionframingwithdrywallscrewsatmaximum300mm
centres
Notes:ThisdrawingshouldbereadinconjunctionwiththerelevantsectionsofthemanufacturerscurrentproductliteraturewewoulddrawyourattentiontotheConstruction(DesignandManagement)Regulations1994andtheApprovedCodeof
LibraDCchannelfixedat600mmcentres15mm
max150mmflatplateoption2
15mmuppermostboardfixing
standardinternalpartition15mm/30or60minutedeflectionhead
firestriporintumescentmastic masticseals
1x19mmCoreboarddroppedsoffit
15mm
15-25mm droppedsoffitsmustbeeitherFireLinegradeboardorGlasrocfor90/120minutedeflectionheads
15-25mm
standardinternalpartition15-25mm/90or120minutedeflectionhead
masticsealsfirestriporintumescentmastic
max150mmLibraDCchannelfixedat600mmcentres15-25mm
wewoulddrawyourattentiontotheConstruction(DesignandManagement)Regulations1994andtheApprovedCodeof
headofpartitionfullyfilledwithrockmineralwool(minimum45kg/m3)
uppermostboardfixing
liningboards(andPlywoodwhereapplicable)asperspecification
Librachannelcutandbentandfixedbetweenstudsto
supportmineralwool
liningboardsfixedtotheirentireperimetertopartitionframingwithdrywallscrewsatmaximum300mm
centres
LibraCorIstudsasperspecification
Notes:Thisdrawingshouldbereadinconjunctionwiththerelevantsectionsofthemanufacturerscurrentproductliterature
ML 21/09/2017 ML/TYP/031
Practicewhichdetailthelegaldutiesofclients,client'sagentsdesignersandcontractorsinvolvedinconstructionprojects. fordiscussionpurposesonly/donotscale
project:
Typical Detail
initials: date: drgno: