INTRA–DC TRANSCEIVERS FORECASTS

Information from Informa PLC

25G server ports begin to ramp in 2016

40G sustains in 2016, continues with rest of market as web-scales jump to 100G

Page 3: INTRA DC TRANSCEIVERS FORECASTS - FIA€¦ · INTRA–DC TRANSCEIVERS FORECASTS Information from Informa PLC 25G server ports begin to ramp in 2016 ... -30 dB is a more realistic

3© 2016 EXFO Inc. All rights reserved.

COMING TO THE RESCUE: WBMMF

Wide Band Multimode Fiber

8 fibers at 850 nm

2 fibers at 850 nm

880 nm

910 nm

940 nm

Page 4: INTRA DC TRANSCEIVERS FORECASTS - FIA€¦ · INTRA–DC TRANSCEIVERS FORECASTS Information from Informa PLC 25G server ports begin to ramp in 2016 ... -30 dB is a more realistic

4© 2016 EXFO Inc. All rights reserved.

40G-100G REQUIREMENTS: IEEE 802.3BA

OM4 fiber IL max. requirement and reach performance

will be the same for WBMMF

Page 5: INTRA DC TRANSCEIVERS FORECASTS - FIA€¦ · INTRA–DC TRANSCEIVERS FORECASTS Information from Informa PLC 25G server ports begin to ramp in 2016 ... -30 dB is a more realistic

5© 2016 EXFO Inc. All rights reserved.

ORL IS IMPORTANT TOO

-30 dB is a more realistic target for 25G+ line rate. Bad

reflection close to active equipment can be bad

-20dB won’t allow you to detect any potential Optical

Return Loss problem

Page 6: INTRA DC TRANSCEIVERS FORECASTS - FIA€¦ · INTRA–DC TRANSCEIVERS FORECASTS Information from Informa PLC 25G server ports begin to ramp in 2016 ... -30 dB is a more realistic

6© 2016 EXFO Inc. All rights reserved.

TIGHT BUDGET AND MM IS CHALLENGING

Core diameter differences

Numerical Aperture differences

Core/Cladding concentricity errorFiber Mismatch

Light source/light coupled into the

fiber

Page 7: INTRA DC TRANSCEIVERS FORECASTS - FIA€¦ · INTRA–DC TRANSCEIVERS FORECASTS Information from Informa PLC 25G server ports begin to ramp in 2016 ... -30 dB is a more realistic

7© 2016 EXFO Inc. All rights reserved.

OM4 PERFORMANCES REQUIREMENTS

TIA-492AAAD specifications for OM4 Fiber, September 2009

A core concentricity of 2 microns for a 50 micron

core fiber produces an attenuation of 0.47 dB

Page 8: INTRA DC TRANSCEIVERS FORECASTS - FIA€¦ · INTRA–DC TRANSCEIVERS FORECASTS Information from Informa PLC 25G server ports begin to ramp in 2016 ... -30 dB is a more realistic

8© 2016 EXFO Inc. All rights reserved.

LAUNCH CONDITIONS: CONNECTOR OFF-SET

LED

VCSEL

FP-LaserModCon

Page 9: INTRA DC TRANSCEIVERS FORECASTS - FIA€¦ · INTRA–DC TRANSCEIVERS FORECASTS Information from Informa PLC 25G server ports begin to ramp in 2016 ... -30 dB is a more realistic

© 2016 EXFO Inc. All rights reserved. 9

THE MANDREL WRAP AS A MODE CONDITIONERPrevious technique used before Encircled Flux

On the LS side wrap the TC

around 5 times

Measurement variability due to:

#1 Mode power distribution

#2 MM fiber characteristics

Page 10: INTRA DC TRANSCEIVERS FORECASTS - FIA€¦ · INTRA–DC TRANSCEIVERS FORECASTS Information from Informa PLC 25G server ports begin to ramp in 2016 ... -30 dB is a more realistic

10© 2016 EXFO Inc. All rights reserved.

ENCIRCLED FLUX (EF) TEMPLATE

IEC 61280-4-1 Ed 2.0, Fibre-optic communication subsystem test procedure –

Part 4-1:Installed cable plant – Multimode attenuation measurement (Belden)

10GbE fiber-optic testing, requires Encircled Flux (EF) metric, slightly under-filled, launching conditions to satisfy the required

REPEATABILITY, REPRODUCIBILITY and UNCERTAINTYand provides good correlation between the loss and connector lateral off-set

Page 11: INTRA DC TRANSCEIVERS FORECASTS - FIA€¦ · INTRA–DC TRANSCEIVERS FORECASTS Information from Informa PLC 25G server ports begin to ramp in 2016 ... -30 dB is a more realistic

11© 2016 EXFO Inc. All rights reserved.

LSPM – EF compliant

OTDR – EF compliant

ATTENUATION MEASUREMENTS METHODS

MMF Link

MLC

850 nm -

1300 nm

Laser

Variable Mode

Conditioner

Speckle

Scrambler

Launching

CableModal

interference

noise reduction

850 nm -

1300 nm

Power meter

MMF Link

MLC

850 nm - 1300 nm

OTDR

Variable Mode

Conditioner

Speckle

Scrambler

Launching

CableModal

interference

noise reduction

MLC: Mode Launch Conditions

Page 12: INTRA DC TRANSCEIVERS FORECASTS - FIA€¦ · INTRA–DC TRANSCEIVERS FORECASTS Information from Informa PLC 25G server ports begin to ramp in 2016 ... -30 dB is a more realistic

12© 2016 EXFO Inc. All rights reserved.

1- OFL/ Mandrel Wrap per TIA-426- 14-A, Method B

2- Encircled Flux TIA-426-14-B, Annex A

COMPARATIVE OLTS MEASUREMENTS

Source: Optical loss testing in the field is not as simple as it seems, Belden (2011)

Page 13: INTRA DC TRANSCEIVERS FORECASTS - FIA€¦ · INTRA–DC TRANSCEIVERS FORECASTS Information from Informa PLC 25G server ports begin to ramp in 2016 ... -30 dB is a more realistic

13© 2016 EXFO Inc. All rights reserved.

IT’S A WRAP.

1. Wide Band Multimode Fiber (WBMMF) and SWDM4

transceivers shall develop a competitive and affordable 40G-

100G proposition on both CAPEX and OPEX sides

2. Using a Mandrel can result in a large measurement variability

3. Encircled Flux (EF) metric for MMF insures the required

testing REPEATABILITY, REPRODUCIBILITY and

UNCERTAINTY in tighter budget situation such as IEEE

802.3ah 40G-100G requirements

Page 14: INTRA DC TRANSCEIVERS FORECASTS - FIA€¦ · INTRA–DC TRANSCEIVERS FORECASTS Information from Informa PLC 25G server ports begin to ramp in 2016 ... -30 dB is a more realistic

14© 2016 EXFO Inc. All rights reserved.

VISIT LINKED-IN GROUP: DATA CENTER FIBER

DATA CENTER FIBERVendor agnostic forum

https://www.linkedin.com/grp/home?gid=8424957

Page 15: INTRA DC TRANSCEIVERS FORECASTS - FIA€¦ · INTRA–DC TRANSCEIVERS FORECASTS Information from Informa PLC 25G server ports begin to ramp in 2016 ... -30 dB is a more realistic