1 Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential BY IMRAN HASHMI INTRODUCTION TO GENEX ASSISTANCE

Introduction to Genex Assistance

Embed Size (px)

DESCRIPTION

Genex Assistant

Citation preview

1Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

BY

IMRAN HASHMI

INTRODUCTION

TO

GENEX ASSISTANCE

2Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

The GENEX Assistant is excellent software tool for

Post-Processing 2G & 3G Drive Test Data.

With the GENEX Assistant, you can:

Have a panorama view of network performance

Locate network troubles

Improve network quality

Verify network planning and optimization

3Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Functions of the Genex Assistant

Analyzing the test data in WCDMA GSM dual mode

The Assistant analyzes the test data in the WCDMA and GSM networksThe Assistant also has the independent display systems for separately displaying the engineering parameters and real-time data

Test data playback

The Assistant supportsManual or automatic play of the test dataDisplay of measurement parameters for trouble spots in detailNetwork problems locating in a quick manner

4Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

FOR POST PROCESSING OF LOGFILE IN

GENEX ASSISTANCE WE NEED TO

OPEN A NEW PROJECT

ANALYSIS OF LOGFILE

5Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

NEW PROJECT

STEP-1 PROJECT NAME ( TEST 01 )

STEP-2 PROJECT PATH ( LOCATION TO SAVE THE PROJECT )

STEP-3 MAP PATH ( Insert the Map from the Location )

STEP-4 DATASET NAME ( LOGFILE NAME )

6Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Opening a New Project

7Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Project Path to Save It

8Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Log file Name

9Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

ANALYSIS LOG FILE IMPORTING

Step 1     Select a dataset from the Project tab in the navigation view

Step 2     Right-click the dataset and choose Import Test Data Import GENEX Probe on the shortcut menu

Step 3     In the Import GENEX Probe log File as shown below

10Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Import the Type of Log File

11Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

CLICK BROWSE FOR LOGFILE LOCATION

12Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

COMBINE DATA ANALYSIS

ASSISTANCE CAN SUPPORT IMPORTING MORE THAN ONE LOG FILE AS IT COMBINES THESE DEVICES AND RE-ANALYZE THE EVENTS

Step 1     Select a dataset from the Project tab in the navigation view

Step 2     Choose Dataset > Combine Device > Combine UE

Step 3     Select multiple devices from PreCombine in the displayed Combine Device

13Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

14Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

New Combined Log file

15Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

16Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

IMPORTING THE MAP DATA

VECTOR

PLACES

CLUTTER

Step 1 Select the Map Layer Window and right click.

Step 2 Select the location for the data to import.

17Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Layer Control

18Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Filtering Test Data

The Assistant can filter the imported data. This feature is capable of comparing the data and executing some simple logical calculations.

To filter test data, perform the following steps:

Step 1 Select a dataset from the Project tab in the navigation view.

Step 2 Choose Dataset > Filter Imported Data

19Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

20Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Select the Desired Filter

Click on Insert

Click on Excute

21Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Introduction to Engineering Parameters Engineering parameter fields

Field RemarksWhether Mandatory to Be Filled In

Longitude Longitude (decimal) Yes

Latitude Latitude (decimal) Yes

Azimuth Azimuth (°C) No

Down Tilt Down tilt angle (°C) No

E-Down Tilt Embedded down tilt angle (°C)

No

M-Down Tilt Mechanical down tilt angle (°C)

No

Ground Height Antenna ground height No

Altitude Antenna altitude No

22Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Perform the following steps to import Engineering Parameters

Step 1     Select a dataset from the Project tab in the navigation view.                                Step 2     Choose Dataset > Import Engineering Parameter, and select WCDMA or GSM based on the test data.                                Step 3     In the displayed dialog box, perform the following operations

Open the Excel file for saving the engineering parameters. Select the sheet for displaying the engineering parameters.

Step 4     Click OK.

23Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

If all the fields in the sheet can match the parametersthe Assistant automatically imports the engineering parameters

If no field in the sheet can match the parameters

Step 5     Match the missing engineering parameter fields one by one. For details, refer to description of button functions

Step 6     Click the  button to import the data. After the data is imported, the site data is automatically displayed on the map.

24Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Step:01 Click on Dataset Name

Step:02

Select Type

25Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Step:03 Open the Table

Step:04 Import the Excel file

26Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Engineering Parameters Display

Engineering Parameters Display

27Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

DRIVE TEST PLOTS

RX LEVEL PLOT

RXLEVEL FULL

RXLEVEL SUB

28Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

29Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

RX QUALITY PLOT

RX QUAL FULL

RX QUAL SUB

30Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

31Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

OTHER DIFFERENT TYPE

OF PLOTS

32Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential BCCH PLOT

33Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential BSIC PLOT

34Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential FER PLOT

35Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential C/I PLOT

36Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential HANDOVER PLOT

37Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

GSM DRIVE TEST STATISTICS

GENEX ASSISTANCE CAN PROVIDE THE DETAIL REPORT OF THE DRIVE TEST

Report: WCDMA Scanner Neighbor Cell

Report: WCDMA Scanner Handover Statistic

Report: WCDMA UE Call Setup

Report: WCDMA UE Call Statistics

38Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Report: WCDMA UE Call Timing Analysis

Report: WCDMA UE Crossingtable HSDPA

Report: WCDMA UE RRC Setup Statistics

Report: GSM Drive Test Statistics

Report: GSM UE Call Statistics Analyse

Report: GSM Handover Statistic

39Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

40Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

GSM DRIVE TEST STATISTICS

The GSM Drive Test Statistics report provides the statistics on RXlevel, voice quality, and so on, as listed in Table

Item DescriptionRxLev RX level in connected state

BCCH RxLev RX level in connected or idle state

RxLev as Distance Distance values for RX level > 90 dBm and RX level < 90 dBm

RxQual Statistics on quality and distance

TA Number of data points in each TA scope

Call Setup Time Number of data points in each scope of call setup duration as per call

41Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

RxLev_Sub(dBm) Distance(km) %Total Count

Avg

-70 to -10 10.90 60.22 % 3152 -59.30

-80 to -70 5.55 30.66 % 1861 -75.06

-90 to -80 1.52 8.40 % 548 -83.48

-100 to -90 0.11 0.61 % 33 -92.67

-120 to -100 0.03 0.17 % 12 -101.00

Total 18.10   5606 -67.18

RxLev_Sub(dBm)

42Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

RxQual sub Count % Distance(km) %

7 153 2.73 % 0.79 4.35 %

6 146 2.60 % 0.60 3.33 %

5 143 2.55 % 0.62 3.45 %

4 157 2.80 % 0.62 3.40 %

3 192 3.42 % 0.92 5.11 %

2 121 2.16 % 0.47 2.61 %

1 203 3.62 % 0.72 3.99 %

0 4491 80.11 % 13.35 73.77 %

Total 5606   18.10  

RxQual_Sub

43Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

TA Count %

32 to 63 0 0.00 %

10 to 32 0 0.00 %

5 to 10 0 0.00 %

4 to 5 0 0.00 %

3 to 4 5 0.09 %

2 to 3 41 0.74 %

1 to 2 688 12.47 %

0 to 1 4785 86.70 %

Average 0.14  

Number of data points in each TA Scope

44Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Call Setup Time (Alerting - ChannelReq )  

Time Count % Avg

0s<=x<2s 0 0.00 % 0.00

2s<=x<4s 6 21.43 % 3.93

4s<=x<6s 21 75.00 % 4.54

6s<=x<8s 1 3.57 % 7.00

8s<=x<10s 0 0.00 % 0.00

10s<=x<12s 0 0.00 % 0.00

12s<=x<15s 0 0.00 % 0.00

15s<=x<20 0 0.00 % 0.00

x>=20s 0 0.00 % 0.00

Total 28   4.50

CALL SETEUP TIME

45Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Microsoft Excel Worksheet

RxQual

Call Setup Time

TA

RxLev_Sub + RxLev_Idle(dBm)

REPORTS IN DEATAIL

46Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

GSM MS Call Analysis

GSM MS Call Statistics

GSM MOS Statistics

REPORTS IN DEATAIL

Microsoft Excel Worksheet

47

Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential