Inventory of radioactive sources present in the cavern at pit 8
Gloria Corti
Experimental Area Meeting
05 August 2008
LHCb Experimental Area Meeting - 05 August 2008 Gloria Corti
Page 2
HCAL sources Hadron CALorimeter uses 2 137Cs sources for calibration one per half
detector gamma sources: nº4145RP (330 MBq) and nº4146RP (300 MBq)
Notice at PZ85 and PM85 of presence of sources in UX85-B with map indicating location of garages
garage on floor of electronics platform on top of HCAL, source blocked inside
UX85-B conventional area when source in garage (≤ 0.5 µSv/h at 40 cm)
LHCb Experimental Area Meeting - 05 August 2008 Gloria Corti
Page 3
HCAL sources
EDMS 917876: safety manual and operational procedure for scan Calibration scan announced at least 48 hours in advance and notices in
PZ85 and PM85 take place from 21:00 in the evening to 7:00 in the morning
Flashing panels bottom of Calorimeters stairs and top of gantry at exit of source(s)
UX85-B is a supervised area during scan for incident if source would stop during scan
Measurements confirm UX85-C is not classified
AD6 HCAL platform
Maximum dose rate measured = 116 µSv/h Total integrated dose = 1.31 µSv.
AD6 Cryo area
Maximum dose rate measured: 0.37 µSv/h Total integrated dose: 0.2 µSv.
RESPONSIBLE: Rustem Dzhelyadin
LHCb Experimental Area Meeting - 05 August 2008 Gloria Corti
Page 4
OT sources
OT uses 3 x 90Sr source + 1 55Fe for irradiation and scanning gas quality and chamber response beta sources: no. 4251RP(27 MBq)–4298RP(70MBq)–4299RP(70MBq), X-ray:
no. 3398RP (9MBq)
2828/U1-A06
2828/U1-A06(6.0 x 4.0 m2)
RADIOACTIVE SOURCEposition when used in the
room
ROOM DETAILS
UX85 - LOCALIZATION OF RADIOACTIVE SOURCES AT 2828/U1-A06
SAFE where the sources are stored when not used.
Sources kept in a safe in a locked room in UX85-A
Panel on the door
One beta source used in the room for gas quality with small panel
LHCb Experimental Area Meeting - 05 August 2008 Gloria Corti
Page 5
OT sources
• EDMS 942795: safety manual and operational procedure for scan on OT frame
• EDMS in preparation for irradiation on pillar• Signs in place before installation of source, 2 OT halves chambers open
RESPONSIBLE: Antonio Pellegrino
LHCb Experimental Area Meeting - 05 August 2008 Gloria Corti
Page 6
Muon source
MUON uses 1 241Am for gas quality alpha and low energy gamma
At the moment in gas building on the surface, will be moved in UX85-A in 2828/U1-A06
EMDS 886019: Safety manual and operation procedure kept in a safe, panel when in use
RESPONSIBLE: Burkhard Schmidt
LHCb Experimental Area Meeting - 05 August 2008 Gloria Corti
Page 7
DELPHI sources
432 241Am sources (alpha) in HPC module of the Electromagnetic Barrel Calorimeter – Not accessible
no. 2946RP, 3.2 MBq on 16.10.1987 Responsible Gloria Corti
24 55Fe in TPC of Delphi – Not accessible
2909-2925RP 370 MBq on 03.09.1987 2929-2934RP, 2936RP, 2.41 MBq on
12.02.2007 Responsible Philippe Charpentier