Multi Series Inverter Multi-Split System Air Conditioners MHIAA is proudly sponsoring Monika’s Doggie Rescue

Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

Multi SeriesInverter Multi-Split System Air Conditioners MHIAA is proudly sponsoring

Monika’s Doggie Rescue

Page 2: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

MULTI series Air Conditioners 2013

2 Multi SeriesInverter Multi-Split System Air Conditioners.

The ideal solution for air conditioning multiple rooms

Page 3: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

A home typically has many areas such as bedrooms, living spaces and study rooms. Therefore, to provide total comfort for your home, a multi-split system is recommended so each room can have its own air conditioner.

This can be achieved through a Mitsubishi Heavy Industries inverter multi-split system which delivers optimum heating or cooling for everyone, no matter where they are in the home and no matter what size the room may be. Silent, powerful, energy ef� cient and utilising advanced technologies, a Mitsubishi Heavy Industries inverter multi-split system is the solution for homes with many rooms and occupants.

3

WE

LCO

ME

Page 4: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

MULTI series Air Conditioners 2013

4

CompactA Mitsubishi Heavy Industries inverter multi-split system allows 2 to 6 indoor units to be connected to a single outdoor unit. This allows multiple rooms to be conditioned without adding clutter to the exterior of your home. One compact multi-split outdoor unit instead of many outdoor units not only adds to the ascetic appeal your home but can be imperative when there is not much space available, for example, when installing outdoor units on balconies or verandahs.

Installation FlexibilityWith a generous maximum piping length of 70m*, you are given greater freedom to decide where the indoor units will be installed to optimise interior space and convenience. In addition, a maximum height difference of 25m* for the indoor units means the Mitsubishi Heavy Industries inverter multi-split system can easily service the rooms for multi storey homes.

Variety of Indoor UnitsThe indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette types in a wide range of capacities. This makes hundreds of combinations possible for your home. You can choose the right type of indoor unit to complement the interior décor and match the size of each room.

*Please check model specifi cations as these pipe lengths and height differences do not apply to all models.

Page 5: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

5

MU

LTI C

ON

CE

PT

Independent Control and ComfortEach indoor unit comes with its own remote allowing the unit to be independently switched on/off and have the temperature adjusted as needed. The conditions of rooms can vary greatly depending on many variables such as the number of occupants or the way the room is used. With a range of comfort, air fl ow and convenience functions on each indoor unit, you can adjust the settings to match the requirements of a room without affecting other ones. When a room is unoccupied you can switch off the unit to reduce ineffi cient energy use.

5 Year WarrantyWhen you buy a Mitsubishi Heavy Industries inverter multi-split system, you are getting an air conditioning solution from a company that some of the highest quality products in the industry. Mitsubishi Heavy Industries enjoys a reputation for outstanding quality and is highly respected both in the Australian and overseas markets. With our 5 Year Warranty covering the parts, labour and compressor, you can peace of mind that your new Mitsubishi Heavy Industries inverter multi-split system will continue to deliver air-conditioning comfort to your home through the years.

Page 6: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

MULTI series Air Conditioners 2013

66

Easy operationAll settings done by tapping touch screen panel

Operation mode

Cooling Dry Auto HeatingFan

Operation mode setting screen

The operation mode canbe selected by simply tappingthis button.

Setting temperature screen

You can select the desired temperature by tapping the ▲▼

button.

Main functions

Energy managementPeak cut timer • Automatic temperature set back • Weekly timer • Set ON/OFF timer by hour • Set ON/OFF timer by clock • Fan only operation • Sleep timer

ComfortIndividual fl ap control • High power operation • External ventilation ON/OFF • Warm up operation • Automatic fan speed • Temperature increment setting by 0.5ºC

ConvenienceLCD contrast setting • Back light setting • Filter clean sign • Control sound • Outdoor silent mode • Summer time setting • Home leave mode • Indoor & outdoor temperature display • Heating standby display • Defrosting operation display • Auto cooling/heating display • ºC/ºF display • Administrator settings • Room name setting

ServiceError code display • Operation data display • Next service data display • Contact company display • USB connection (mini-B)

Page 7: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

7

CO

NT

RO

L & F

UN

CT

ION

S

Comfortable Functions

Automatic OperationThe air conditioner automatically selects from heating, cooling or dry operation.

"HI POWER" OperationThe unit can operate continuously in HI POWER mode for 15 minutes. This mode is used to reach the desired temperature quickly.

Three "Hot" System‘Hot start’ enables the unit to begin heating operation quickly.‘Hot spurt’ is a fast heating system that works to increase the temperature setting by two degrees.‘Hot keep’ is used during the automatic defrost cycle to prevent cool air being circulated.These three operational control systems help ensure comfortable and efficient heating.

3HOT

St

art

Keep

Spurt

On TimerThis enables the operation to start a little earlier so that the room is near to the set temperature at ON time.

On Timer

Microcomputer-Operated DefrostingThis function automatically eliminates frost and helps minimize excessive operation in other modes.

MC

When removing the air inlet panel for internal cleaning or other reasons, open the grill by 65 degrees and then pull it to the side.

Detachable Indoor Air Inlet PanelThe air inlet panel on the indoor unit opens and closes easily making filter cleaning simple. The suction panel can be easily removed.

Detachable

Self-Diagnostic FunctionIf the air conditioner malfunctions an internal microcomputer runs a self diagnosis. Inspection and repair should be performed by authorized dealers.

DiagnosticSelf

Power blackout auto restart function records the operational status of the air conditioner immediately prior to being switched off by a power supply interruption. The unit automatically resumes operations in the mode and temperature set point after the power has been restored.

Auto Restart FunctionRestart

Auto

On the indoor unit there is a back up on/off switch. The system will operate in the previous mode.

Back-up SwitchBack-upSwitch

Others

Economy ModeEconomyThe unit achieves effective energy saving operation while still keeping a comfortable cooling or heating operation.

Dry OperationDRY The unit dehumidifies the room by intermittent cooling operation.

24-hour On/Off Programmable TimerBy combining a start timer with a stop timer you can register two timer operations a day. Once set timers will start or stop the system at the specified time of the day repeatedly.

24h Timer

Off TimerOFF TimerThe unit stops at the specified time.

Sleep ModeSleepThe room temperature is automatically controlled during the set sleep mode period ensuring that the room temperature will not get too hot or cold.

Convenience & Economy Functions

Maintenance & Prevention Functions

Comfortable Air Flow Functions

Slant forwardblowing

HEATING

Auto Flap ModeThe unit automatically selects the optimal angle whatever the operation mode.

Auto Flap Horizontal blowingCOOLING & DRY

Fuzzy Auto ModeAutomatically the unit determines its operating mode and temperature setting based on a fuzzy calculation and adjusts the inverter frequency.

You can choose the best heating or cooling pattern with the touch of a button.

3D Auto

Auto

Thick line : moves quicklyThin line : moves slowly

COOLING & DRY

HEATINGThick line : moves quicklyThin line : moves slowly

Air ScrollThe swing of the flap causes the air flow to spiral and the breeze to reach all corners of the room.

Air Scroll

Filter

Photocatalytic Washable Deodorizing FilterIt keeps air fresh by deodorizing the molecules causing odor. The deodorizing ability can be easily restored simply by cleaning and exposing the �lter to the sunlight.

Allergen Clear FilterThe �lter breaks down the pollen, lice, and all allergens that live on cat skins, etc. and deactivates them.

SUNFilterSUNFilterSUNFilter

AllergenFilterAllergenFilterAllergenFilter

SWING FLAPFlap moves up and down continuously.

Memory FlapWhile the flap is swinging it can be stopped at any angle. The flap returns to this position next time the unit starts.

Memory

Up/Down Flap SwingThe Up/Down flap can be adjusted to the preferred angle anywhere between horizontal and perpendicular.

UP/DOWN

Lateral SwingThe louver swings from right to left automatically. Louver angle can be fixed in any desired position.

Lateral

Swing

You can set the left-right air �ow directions when you install the air conditioner near the side wall by remote controller operation.

Positioning of

installation

Positioning of Installation

Both lower and upper air outlets and upper air outlet can be selected. (SRF models only)

Air outletselection

Air Outlet Selection

With wireless “Luminous” remote controls that even “glow in the dark”, it is possible to operate all desired functions of the unit with the click of a button.

Luminous

24-hour IONThe air conditioner body has a tourmaline coated sheet. Negative ions (2,500 -3,000/cc) are generated when the air conditioner is not running, allowing you to experience them without incurring any electrical cost.

24h ION

Luminous Button

Natural Enzyme FilterEnzymes used in the �lter are naturally occurring lytic enzymes which attack cell walls of microorganisms trapped on the �lter and destroy them.

See details on page 2.

EnzymeFilter

EnzymeFilter

EnzymeFilter

Self CleanOperationSelf CleanOperationSelf CleanOperation

AllergenSystemAllergenSystemAllergenSystem

Functions.

Page 8: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

MULTI series Air Conditioners 2013

8

Advanced Technology.

DC PAM inverterAn inverter system has a number of advantages over a constant speed system. Its variable speed compressor outputs can ensure quick cooling or heating after start up and attains a set temperature more quickly. The air conditioner can slow down the compressor speed to save energy whilst keeping comfortable conditions. The compressor is DC motor driven so it provides superior performance.

High Ef� ciency.

CONVENTIONALINVERTER

CONVENTIONAL

Time

Room Temp.

ON

Less advanced technology does not addressthe ON/OFF cycle issue.

OFFRated Capacity

OFF

Set Temp.

Compressor(rps)

DC PAMINVERTER

DC PAMINVERTER

Time

Room Temp.

Even Temperature

ONRated Capacity

Utmost comfort and energy efficiency achievedwith large output power and control optimisation

Set Temp.

Compressor(rps)

PWMPAM

DC compressor motor

Mot

or E

ffic

ienc

y(%

)

Magnet Motor

Induction Motor

Low High

Improving

Improving

Revolution speedINVERTER

DCPAM

PowerActiveModule

New inverter control (Vector control)New Inverter Control has applied the new advanced technology of Vector control enabling:- • Smooth operation from low to high speed• Smooth Sine Voltage Wave form is achieved • Energy effi ciency has improved in low speed range

Propeller fanThe new propeller fan was carefully matched with a fan motor in order to keep the same capacity as that of previous models with less electrical consumption.

Superior corrosion resistanceThe base of the outdoor unit is hot dipped to provide superior corrosion and scratch resistance.

Outdoor unitRedesigned by changing the � n con� guration from � at sheet to new M shape � n, ef� ciency has been improved. An optimum balance of heat transfer and air � ow has been achieved.

Silicon-coated PCBThe printed circuit board of the outdoor unit is coated by silicon. The coating ensures longevity of the board in humid conditions.

Page 9: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

9

FE

ATU

RE

SAdvanced Technology.

All SRK, SRF

Applied models

SRK50/60ZJX, SRK-ZKSRF-50ZJX

Applied models

60dB 50dB 40dB 30dB 21dB

SRK20ZJX-S(In the Cooling Lo mode)

70dB

60dB

50dB

40dB

30dB

20dB

10dB

0dB

Comparison with familiar noises in our everyday life

Normal conversations

Quiet of�ce

In the library Late night in a

typical suburban area

21dB

20m

30mMaximum height difference

Maximum pipe length

For the capacities under low temperature conditions, refer to technical manual.

50403020100-10-20

Heating

Cooling +46°C

+21°C

-15°C

-15°CSRK-ZJX, SRK-ZK, SRK-ZJ, SRF-ZJX

Applied models

All SRK, SRF, SRR, FDTC

SRK50/60ZJX, SRK-ZK, SRK35/50ZJ, SRK-ZJX

All SCM-appearance may varyAll SRK, SRF

Applied models

SRK50/60ZJX, SRK-ZKSRF-50ZJX

Applied models

60dB 50dB 40dB 30dB 21dB

SRK20ZJX-S(In the Cooling Lo mode)

70dB

60dB

50dB

40dB

30dB

20dB

10dB

0dB

Comparison with familiar noises in our everyday life

Normal conversations

Quiet of�ce

In the library Late night in a

typical suburban area

21dB

20m

30mMaximum height difference

Maximum pipe length

For the capacities under low temperature conditions, refer to technical manual.

50403020100-10-20

Heating

Cooling +46°C

+21°C

-15°C

-15°CSRK-ZJX, SRK-ZK, SRK-ZJ, SRF-ZJX

Applied models

All SRK, SRF, SRR, FDTC

SRK50/60ZJX, SRK-ZK, SRK35/50ZJ, SRK-ZJX

All SCM-appearance may vary

All SRK, SRF

Applied models

SRK50/60ZJX, SRK-ZKSRF-50ZJX

Applied models

60dB 50dB 40dB 30dB 21dB

SRK20ZJX-S(In the Cooling Lo mode)

70dB

60dB

50dB

40dB

30dB

20dB

10dB

0dB

Comparison with familiar noises in our everyday life

Normal conversations

Quiet of�ce

In the library Late night in a

typical suburban area

21dB

20m

30mMaximum height difference

Maximum pipe length

For the capacities under low temperature conditions, refer to technical manual.

50403020100-10-20

Heating

Cooling +46°C

+21°C

-15°C

-15°CSRK-ZJX, SRK-ZK, SRK-ZJ, SRF-ZJX

Applied models

All SRK, SRF, SRR, FDTC

SRK50/60ZJX, SRK-ZK, SRK35/50ZJ, SRK-ZJX

All SCM-appearance may vary

All SRK, SRF

Applied models

SRK50/60ZJX, SRK-ZKSRF-50ZJX

Applied models

60dB 50dB 40dB 30dB 21dB

SRK20ZJX-S(In the Cooling Lo mode)

70dB

60dB

50dB

40dB

30dB

20dB

10dB

0dB

Comparison with familiar noises in our everyday life

Normal conversations

Quiet of�ce

In the library Late night in a

typical suburban area

21dB

20m

30mMaximum height difference

Maximum pipe length

For the capacities under low temperature conditions, refer to technical manual.

50403020100-10-20

Heating

Cooling +46°C

+21°C

-15°C

-15°CSRK-ZJX, SRK-ZK, SRK-ZJ, SRF-ZJX

Applied models

All SRK, SRF, SRR, FDTC

SRK50/60ZJX, SRK-ZK, SRK35/50ZJ, SRK-ZJX

All SCM-appearance may vary

All SRK, SRF

Applied models

SRK50/60ZJX, SRK-ZKSRF-50ZJX

Applied models

60dB 50dB 40dB 30dB 21dB

SRK20ZJX-S(In the Cooling Lo mode)

70dB

60dB

50dB

40dB

30dB

20dB

10dB

0dB

Comparison with familiar noises in our everyday life

Normal conversations

Quiet of�ce

In the library Late night in a

typical suburban area

21dB

20m

30mMaximum height difference

Maximum pipe length

For the capacities under low temperature conditions, refer to technical manual.

50403020100-10-20

Heating

Cooling +46°C

+21°C

-15°C

-15°CSRK-ZJX, SRK-ZK, SRK-ZJ, SRF-ZJX

Applied models

All SRK, SRF, SRR, FDTC

SRK50/60ZJX, SRK-ZK, SRK35/50ZJ, SRK-ZJX

All SCM-appearance may vary

Live Bacteria Count on Measured Test Pieces

Test Pieces 1) Products with Antimicrobial and Antifungal Treatment

TestedContaminant Measurement Test Pieces

Bacteria Count Per Test PieceMeasurement 1 Measurement 2 Measurement 3

Escherichia coli IFO 3972 coli

Aspergillusniger

Staphylococcusaureus

Immediately after contact

After 24 hrs at 35°C

Not treated 1.9 x 105

<103.8 x 106

1.4 x 105

<108.6 x 105

1.5 x 104

<101.0 x 104

1.6 x 105

<104.9 x 106

1.6 x 105

<104.5 x 105

2.2 x 104

<101.2 x 104

1.3 x 105

<107.2 x 106

1.3 x 105

<103.6 x 105

1.6 x 104

<102.5 x 104

Test piece 1Not treated

Immediately after contact

After 24 hrs at 35°C

Not treated

Test piece 1Not treated

Immediately after contact

After 24 hrs at 35°C

Not treated

Test piece 1Not treated

All SRK

Applied models

withoutAnti-microbial

with Anti-microbial

Aspergillus niger IFO 6341

withoutAnti-microbial

with Anti-microbial

Escherichia coli IFO 3972

In tests conducted at the Mitsubishi Heavy Industries Nagoya Research Lab, 24 hrs after contact with bacteria, cultured on agar media.

Comparison of growth of bacteria and mold on fan surfaces(microscopic image)

Comparison of growth of bacteria and mold on fan surfaces(microscopic image)

Wide operation rangeHeating and cooling operations are possible at an outdoor temperature as low as –15°COur advanced technology has improved the heating and cooling operation range. Units can be installed when heating or cooling operation is required at low ambient conditions down to -15°C.

Quiet operationSilent airflow and long reach

The secret of quiet operationThe combination of the jet air� ow system and serration stabilizer con� guration ensures uniform breeze to every corner of the room. It also makes it possible to lower the operation noise further by minimizing the interaction between air� ow and the fan.

Three sensorsControl of room temperature and humidity is very important for people to live a comfortable life. Use of three sensors to control indoor temperature, indoor humidity and outdoor temperature enable the unit to obtain optimum air-conditioning.

Washable fi lter and easy cleaning of the air inlet panel Removing the air � lter is quite easy. Keeping the air � lter clean is an effective way to save energy and keep the original powerful performance of your unit.The air inlet panel is also removable and can be cleaned easily.

Anti-microbial treatmentThe indoor fan has undergone anti-microbial treatment to resist growth of mould and germs. Mould creating odours which can occur when an air conditioner is not in operation are prevented.

Anti-microbial indoor fanAnti-microbial specifications and design will deliver cleanliness and safety

Page 10: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

MULTI series Air Conditioners 2013

10 3D AUTO Vertical + Horizontal AIR SCROLL.

SRK-ZJX, SRK-ZJ

SRK63/71/80ZK, Manual Setting only

Applied models

3D AUTO

Swing

Vertical Swing

Horizontal Air Scroll 8 Direction Swing

1 2 3 4

8 7 6 5

Swing Spot Wide

3

4

2

1

Cool Shower

Cool Shower

Floor Heating

Floor

Swing

Swing

Swing

Hi-Power (Quick)

Wide Swing (Every Corner)

Center (Long)

Wide-Air (Equal)

3 motors make 3 independent controls3 motors make 3 independent controls

Programmed air distribution

SRK-ZJX, SRK-ZJ

SRK63/71/80ZK, Manual Setting only

Applied models

3D AUTO

Swing

Vertical Swing

Horizontal Air Scroll 8 Direction Swing

1 2 3 4

8 7 6 5

Swing Spot Wide

3

4

2

1

Cool Shower

Cool Shower

Floor Heating

Floor

Swing

Swing

Swing

Hi-Power (Quick)

Wide Swing (Every Corner)

Center (Long)

Wide-Air (Equal)

3 motors make 3 independent controls3 motors make 3 independent controls

Programmed air distribution

SRK-ZJX, SRK-ZJ

SRK63/71/80ZK, Manual Setting only

Applied models

3D AUTO

Swing

Vertical Swing

Horizontal Air Scroll 8 Direction Swing

1 2 3 4

8 7 6 5

Swing Spot Wide

3

4

2

1

Cool Shower

Cool Shower

Floor Heating

Floor

Swing

Swing

Swing

Hi-Power (Quick)

Wide Swing (Every Corner)

Center (Long)

Wide-Air (Equal)

3 motors make 3 independent controls3 motors make 3 independent controls

Programmed air distribution

SRK-ZJX, SRK-ZJ

SRK63/71/80ZK, Manual Setting only

Applied models

3D AUTO

Swing

Vertical Swing

Horizontal Air Scroll 8 Direction Swing

1 2 3 4

8 7 6 5

Swing Spot Wide

3

4

2

1

Cool Shower

Cool Shower

Floor Heating

Floor

Swing

Swing

Swing

Hi-Power (Quick)

Wide Swing (Every Corner)

Center (Long)

Wide-Air (Equal)

3 motors make 3 independent controls3 motors make 3 independent controls

Programmed air distribution

3D AUTO is a one touch programme. Three motors (one vertical working motor + two horizontal working motors) make three independent air � ow controls.The air� ow is uniform, quiet and reaches at long distance from the indoor unit.

Programmed 3D AUTOAutomatic control of air � ow volume and air � ow direction enables comfortable air conditioning of the entire room. In cooling operation, cooled air � ows directly to the ceiling not directly onto the occupants of the room. The comfort cooled air � ow comes down from the ceiling like a soft shower.In heating operation, warm air � ows to the � oor directly and spreads along the � oor. The concentration of the warm air at � oor level increases comfort.

Manual SettingIndividual control of right and left louver enables air � ow direction from the right and the left side of the unit, setting the most preferable air � ow direction and determining whether direct air � ow is required or not.

Page 11: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

11

FE

ATU

RE

SJet air scroll long reach & silent air � ow.

We used the same aerodynamic analysis technology as used in developing jet engines.CFD (computational � uid dynamics) is used for blade shape design and air channels for jet engines. The same technology has been used in our air conditioners. The air� ow of the jets created in this system enables a large volume of air to be blown with a minimum amount of power consumption. The air� ow is uniform, quiet and reaches a long distance from the indoor unit.

New louver The new louver has a new design and shape.It has increased in surface area by 80%. In addition to improved control of the increased air � ow volume, it has improved controllability of the right to left swing function.

Fast SlowColors in the �gure show the air speed.

Aircraft technology was used in the design of the air conditioner’s airflow system

SRK71ZK(in cooling operation)

17m15m

SRK50/60ZJX(in cooling operation)

powerful

Newprevious

80% increased

Newprevious

80% increased

Positioning of InstallationYou can set the left-right air � ow directions when you install the air conditioner near the side wall by remote controller operation.

Long Reach Air FlowThe jet technology enables powerful air� ow ideal for large living areas and commercial premises, increasing your comfort.

Page 12: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

MULTI series Air Conditioners 2013

12 Clean Air.

Catching Allergen on the Filter

AIR Purify

Cooling OperationTo make condensing water.

Heating OperationTo give moisture to the Filter to inactivate allergen

Self-Clean OperationTo dry up the indoor unit

Self Clean OperationThe ‘self clean operation’ is operated for 2 hours after the unit has ceased normal operation. The indoor fan continues to operate on ultra low speed to dry the unit. This restricts the growth of mould. This feature can be selected on the remote control.

Allergen Clear SystemThe ‘Allergen Clear system’ suppresses the in� uence of the allergen caught by the � lter by controlling the temperature and humidity.

Generates the same amount of negative ions as a forest environment

24-hour IONThe air conditioner body has a tourmaline coated sheet. Negative ions (2,500 -3,000/cc) are generated even when the air conditioner is not running, allowing you to experience them without incurring any electrical cost.

The air in your room is kept fresh

Allergen clear systemThe ‘Allergen Clear system’ suppresses the in� uence of the allergen caught by the � lter by controlling the temperature and humidity.

After one weekwithout self clean opration

After one weekwith self clean opration

First in the world20 of Patent Pending

Stop run 2hrs

Normaloperation

Cleanoperation

Shuts off automatically

Situation of mold after one week

Situation of mold after one week

Fungal mycelia expand.

The spore of mold doesn't germinate.

When you execute “Self Clean Operation”When you don’t execute “Self Clean Operation”

Fungal mycelia

Spore of mold

Spore of mold

Stop run 2hrs

Normaloperation

Cleanoperation

Shuts off automatically

Situation of mold after one week

Situation of mold after one week

Fungal mycelia expand.

The spore of mold doesn't germinate.

When you execute “Self Clean Operation”When you don’t execute “Self Clean Operation”

Fungal mycelia

Spore of mold

Spore of mold

Stop run 2hrs

Normaloperation

Cleanoperation

Shuts off automatically

Situation of mold after one week

Situation of mold after one week

Fungal mycelia expand.

The spore of mold doesn't germinate.

When you execute “Self Clean Operation”When you don’t execute “Self Clean Operation”

Fungal mycelia

Spore of mold

Spore of mold

Page 13: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

13

FE

ATU

RE

S

CouplingCell wall

Filter �ber

Enzyme EnzymeBacterium

Powerful sterilizing effect

Enzyme's sterilizing mechanism

Sterilization Mechanism

-COOH

H2N-

Protein structure of allergen

Urea Enzyme

A molecule is decomposed

Slack of high order structure Reduction in a molecule

Inac

tivat

ion

rate

(%)

100

50

0

83.5%93.6%

72.7%83.5%

99.9% 99.0%

Rate of inactivation against allergens collected on the �lter

House dust mite*1 *1 *2 *2 *3 *3

A species of mite Cedar pollen Epithelium of cat Virus i Virus p

Photocatalytic Washable Deodorizing Filter

Allergen Clear Filter

Filter Indoor Unit

Used in models

*1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145

Air

�o

w

Conventional Filter Enzyme Filter

Analysis ZoneAnalysis Zone

Natural Enzyme Filter

SRF-ZJXSRK-ZKSRK-ZJX

1pc

-

1pc

SRK-ZJ

1pc

-

1pc

-

1pc

1pc

1pc

-

1pc

First in the world

CouplingCell wall

Filter �ber

Enzyme EnzymeBacterium

Powerful sterilizing effect

Enzyme's sterilizing mechanism

Sterilization Mechanism

-COOH

H2N-

Protein structure of allergen

Urea Enzyme

A molecule is decomposed

Slack of high order structure Reduction in a molecule

Inac

tivat

ion

rate

(%)

100

50

0

83.5%93.6%

72.7%83.5%

99.9% 99.0%

Rate of inactivation against allergens collected on the �lter

House dust mite*1 *1 *2 *2 *3 *3

A species of mite Cedar pollen Epithelium of cat Virus i Virus p

Photocatalytic Washable Deodorizing Filter

Allergen Clear Filter

Filter Indoor Unit

Used in models

*1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145

Air

�o

w

Conventional Filter Enzyme Filter

Analysis ZoneAnalysis Zone

Natural Enzyme Filter

SRF-ZJXSRK-ZKSRK-ZJX

1pc

-

1pc

SRK-ZJ

1pc

-

1pc

-

1pc

1pc

1pc

-

1pc

First in the world

CouplingCell wall

Filter �ber

Enzyme EnzymeBacterium

Powerful sterilizing effect

Enzyme's sterilizing mechanism

Sterilization Mechanism

-COOH

H2N-

Protein structure of allergen

Urea Enzyme

A molecule is decomposed

Slack of high order structure Reduction in a molecule

Inac

tivat

ion

rate

(%)

100

50

0

83.5%93.6%

72.7%83.5%

99.9% 99.0%

Rate of inactivation against allergens collected on the �lter

House dust mite*1 *1 *2 *2 *3 *3

A species of mite Cedar pollen Epithelium of cat Virus i Virus p

Photocatalytic Washable Deodorizing Filter

Allergen Clear Filter

Filter Indoor Unit

Used in models

*1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145

Air

�o

w

Conventional Filter Enzyme Filter

Analysis ZoneAnalysis Zone

Natural Enzyme Filter

SRF-ZJXSRK-ZKSRK-ZJX

1pc

-

1pc

SRK-ZJ

1pc

-

1pc

-

1pc

1pc

1pc

-

1pc

First in the world

CouplingCell wall

Filter �ber

Enzyme EnzymeBacterium

Powerful sterilizing effect

Enzyme's sterilizing mechanism

Sterilization Mechanism

-COOH

H2N-

Protein structure of allergen

Urea Enzyme

A molecule is decomposed

Slack of high order structure Reduction in a molecule

Inac

tivat

ion

rate

(%)

100

50

0

83.5%93.6%

72.7%83.5%

99.9% 99.0%

Rate of inactivation against allergens collected on the �lter

House dust mite*1 *1 *2 *2 *3 *3

A species of mite Cedar pollen Epithelium of cat Virus i Virus p

Photocatalytic Washable Deodorizing Filter

Allergen Clear Filter

Filter Indoor Unit

Used in models

*1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145

Air

�o

w

Conventional Filter Enzyme Filter

Analysis ZoneAnalysis Zone

Natural Enzyme Filter

SRF-ZJXSRK-ZKSRK-ZJX

1pc

-

1pc

SRK-ZJ

1pc

-

1pc

-

1pc

1pc

1pc

-

1pc

First in the world

CouplingCell wall

Filter �ber

Enzyme EnzymeBacterium

Powerful sterilizing effect

Enzyme's sterilizing mechanism

Sterilization Mechanism

-COOH

H2N-

Protein structure of allergen

Urea Enzyme

A molecule is decomposed

Slack of high order structure Reduction in a molecule

Inac

tivat

ion

rate

(%)

100

50

0

83.5%93.6%

72.7%83.5%

99.9% 99.0%

Rate of inactivation against allergens collected on the �lter

House dust mite*1 *1 *2 *2 *3 *3

A species of mite Cedar pollen Epithelium of cat Virus i Virus p

Photocatalytic Washable Deodorizing Filter

Allergen Clear Filter

Filter Indoor Unit

Used in models

*1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145

Air

�o

w

Conventional Filter Enzyme Filter

Analysis ZoneAnalysis Zone

Natural Enzyme Filter

SRF-ZJXSRK-ZKSRK-ZJX

1pc

-

1pc

SRK-ZJ

1pc

-

1pc

-

1pc

1pc

1pc

-

1pc

First in the world

CouplingCell wall

Filter �ber

Enzyme EnzymeBacterium

Powerful sterilizing effect

Enzyme's sterilizing mechanism

Sterilization Mechanism

-COOH

H2N-

Protein structure of allergen

Urea Enzyme

A molecule is decomposed

Slack of high order structure Reduction in a molecule

Inac

tivat

ion

rate

(%)

100

50

0

83.5%93.6%

72.7%83.5%

99.9% 99.0%

Rate of inactivation against allergens collected on the �lter

House dust mite*1 *1 *2 *2 *3 *3

A species of mite Cedar pollen Epithelium of cat Virus i Virus p

Photocatalytic Washable Deodorizing Filter

Allergen Clear Filter

Filter Indoor Unit

Used in models

*1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145

Air

�o

w

Conventional Filter Enzyme Filter

Analysis ZoneAnalysis Zone

Natural Enzyme Filter

SRF-ZJXSRK-ZKSRK-ZJX

1pc

-

1pc

SRK-ZJ

1pc

-

1pc

-

1pc

1pc

1pc

-

1pc

First in the world

CouplingCell wall

Filter �ber

Enzyme EnzymeBacterium

Powerful sterilizing effect

Enzyme's sterilizing mechanism

Sterilization Mechanism

-COOH

H2N-

Protein structure of allergen

Urea Enzyme

A molecule is decomposed

Slack of high order structure Reduction in a molecule

Inac

tivat

ion

rate

(%)

100

50

0

83.5%93.6%

72.7%83.5%

99.9% 99.0%

Rate of inactivation against allergens collected on the �lter

House dust mite*1 *1 *2 *2 *3 *3

A species of mite Cedar pollen Epithelium of cat Virus i Virus p

Photocatalytic Washable Deodorizing Filter

Allergen Clear Filter

Filter Indoor Unit

Used in models

*1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145

Air

�o

w

Conventional Filter Enzyme Filter

Analysis ZoneAnalysis Zone

Natural Enzyme Filter

SRF-ZJXSRK-ZKSRK-ZJX

1pc

-

1pc

SRK-ZJ

1pc

-

1pc

-

1pc

1pc

1pc

-

1pc

First in the world

Allergen clear � lterThis is the original and only technology to control the temperature and humidity for inactivating allergens

Enzyme + Urea deactivates allergens and kills bacteriaThe allergen clear � lter deactivates pollen lice and allergens that live on cat skin etc. The deactivation secret is the Enzyme-urea compound. It deactivates not only allergens but some bacteria, moulds and viruses. Even if allergen, mould, virus or bacteria � y off the � lter they are deactivated so the air in your room is kept fresh.

Natural enzyme � lter Helps to destroy fungi and bacteria, also effective on viruses and allergenic compounds (Cat hair, dust mite, pollen etc.)

Enzyme � lterThe enzymes used in these � lters are naturally occurring lytic enzymes. Lytic enzymes attack cell walls of microorganisms trapped on the � lter and destroy them. The Natural Enzyme Filter will clean and sanitize air passing through it.

Photocatalytic washable deodorizing � lterThe deodorizing ability of this filter can be easily restored simply by cleaning and exposing to sunlight

This � lter will keep the air fresh by deodorizing the molecules that cause odours. The deodorizing effect can be restored by washing with water and then drying under the sun. This � lter maintains its deodorizing effect even after many repeat uses.

Page 14: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

MULTI series Air Conditioners 2013

14 Ceiling Concealed Type.

RC-E5RC-EX1A RCH-E3

Wired Remote Control Wireless Remote Control

RCN-TC-24W-ER

SRR25~60VF

Ceiling concealed type (SRR)

Models SRR25ZJ-S, 35ZJ-S, 50ZJ-S, 60ZJ-S

455

253

325.4

67035 35

515

3030

(Sus

pens

ion b

olts p

itch)

(Suspension bolts pitch)

Control Box

D

E

D

C

B

Suspension bolts

Drain piping

Liquid piping

VP166.35 1 4" Flare

Model

Gas pipingA

Symbol

12.7 1 2"

Content

SRR25ZJ-S,

9.52 3 8"

SRR50ZJ-S,

M8

Flare Flare

35ZJ-S 60ZJ-S

E Power supply intake 35

Option

Wired remote controllerWireless remote controller

120 196015

017.3

Unit:mm

150

13575

38

Terminal block

Air inlet

Air outlet B

AC

FIG.B

Note 1 The model name label is attached on the lid of the control box.

2 It takes the interface kit SC-BIKN-Eto connect the wired remote controller.

236

FIG.A

8- 2.8Holes for tapping screws 4

7.501047

230

11.2

10522090220105

4117

019

30

100540100

5214

830

174.

430

.3

70318.5 18.5

FIG.A(Air inlet from lower)

In case of filter guide installed(normal condition)

6-M4For hanger plate

177

21

4847528

670

2012

0

32

4040

35 35

FIG.B(Air inlet from rear)

In case of filter guide installed(option)

9- 2.8Holes for tapping screws 4

Holes for tapping screws 4

710

10 24

168 168 168 168

160

40

190

15

15 15

1113

1024

5- 3.3( Mark only)

In case of filter guide taken off

11- 2.8Holes for tapping screws 4

710

168 168 168 168

69423

10 10

23

2424

2080

8040

150

15 15

203.

711

.3

In case of rear panel taken off

Standard Equipment

Page 15: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

15

PR

OD

UC

TS

Ceiling Cassette.

RCN-TC-24W-ER

wireless remote control

Fits into standard 600 x 600 ceiling

Previous(Cooling/Heating)

New(Cooling)

New(Heating)

36

35

34

33

32

31

30

29

28

27

26

25

(dB)

35dB

30dB

32dB

5dBDown

3dBDown

Flexible hose

248mm600mm

FDTC25~60VF

OA OAPanel

300mm

Ceiling surface

Indoor Unit FDTC

OA Spacer

Joint Duct

RC-E5RC-EX1A RCH-E3

Wired Remote Control

Wireless Remote Control

RCN-TC-24W-ER

RCN-TC-24W-ER

wireless remote control

Fits into standard 600 x 600 ceiling

Previous(Cooling/Heating)

New(Cooling)

New(Heating)

36

35

34

33

32

31

30

29

28

27

26

25

(dB)

35dB

30dB

32dB

5dBDown

3dBDown

Flexible hose

248mm600mm

FDTC25~60VF

OA OAPanel

300mm

Ceiling surface

Indoor Unit FDTC

OA Spacer

Joint Duct

RC-E5RC-EX1A RCH-E3

Wired Remote Control

Wireless Remote Control

RCN-TC-24W-ER

RCN-TC-24W-ER

wireless remote control

Fits into standard 600 x 600 ceiling

Previous(Cooling/Heating)

New(Cooling)

New(Heating)

36

35

34

33

32

31

30

29

28

27

26

25

(dB)

35dB

30dB

32dB

5dBDown

3dBDown

Flexible hose

248mm600mm

FDTC25~60VF

OA OAPanel

300mm

Ceiling surface

Indoor Unit FDTC

OA Spacer

Joint Duct

RC-E5RC-EX1A RCH-E3

Wired Remote Control

Wireless Remote Control

RCN-TC-24W-ER

RCN-TC-24W-ER

wireless remote control

Fits into standard 600 x 600 ceiling

Previous(Cooling/Heating)

New(Cooling)

New(Heating)

36

35

34

33

32

31

30

29

28

27

26

25

(dB)

35dB

30dB

32dB

5dBDown

3dBDown

Flexible hose

248mm600mm

FDTC25~60VF

OA OAPanel

300mm

Ceiling surface

Indoor Unit FDTC

OA Spacer

Joint Duct

RC-E5RC-EX1A RCH-E3

Wired Remote Control

Wireless Remote Control

RCN-TC-24W-ER

RCN-TC-24W-ER

wireless remote control

Fits into standard 600 x 600 ceiling

Previous(Cooling/Heating)

New(Cooling)

New(Heating)

36

35

34

33

32

31

30

29

28

27

26

25

(dB)

35dB

30dB

32dB

5dBDown

3dBDown

Flexible hose

248mm600mm

FDTC25~60VF

OA OAPanel

300mm

Ceiling surface

Indoor Unit FDTC

OA Spacer

Joint Duct

RC-E5RC-EX1A RCH-E3

Wired Remote Control

Wireless Remote Control

RCN-TC-24W-ER

RCN-TC-24W-ER

wireless remote control

Fits into standard 600 x 600 ceiling

Previous(Cooling/Heating)

New(Cooling)

New(Heating)

36

35

34

33

32

31

30

29

28

27

26

25

(dB)

35dB

30dB

32dB

5dBDown

3dBDown

Flexible hose

248mm600mm

FDTC25~60VF

OA OAPanel

300mm

Ceiling surface

Indoor Unit FDTC

OA Spacer

Joint Duct

RC-E5RC-EX1A RCH-E3

Wired Remote Control

Wireless Remote Control

RCN-TC-24W-ER

Taking outside air insideOA Spacer TC-OAS-E (option)Joint Duct TC-OAD-E (option)

Utilizing OA spacer which comes as optional equipment, outside air can be taken inside.

Using 1 joint duct: OA comes up to 1.3m3/min.Using 2 joint ducts: OA comes from 1.3 to 2.6m3/min.

Quiet operation(Sound Pressure level in the Lo mode)

“CLEARER”air fl owNew shape & angled louver redirects the air current away from the ceiling, to reduce ceiling stains

Easy installation For wireless control simply insert the infrared receiver kit on a corner of the panel

Compact and convenient 600mm drain pumpDrain can be discharged upward by 600 mm from the ceiling surface close to the indoor unit.It allows a piping layout with a high degree of freedom depending on the installation location.

600 x 600 ceilingIndoor unit size (W:570 x D:570) brings easy installation for 600 x 600 ceiling and Panel size (700 x 700) is suitable for 600 x 600 ceiling. Height is one of the industry's lowest level at 248mm and weight is 16.5kg only.

Page 16: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

MULTI series Air Conditioners 2013

16 Floor Standing.

Right

Left

Rear

Left rear

Left downward

Downward

Right

Left

Rear

Left rear

Left downward

Downward

Right

Left

Rear

Left rear

Left downward

Downward

Right

Left

Rear

Left rear

Left downward

Downward

Sophisticated design With a classy semi fl at front panel in chic white, this series fi ts in all kinds of rooms and creates a relaxing atmosphere. Choice of wall hanging, � oor standing or behind gallery installation is available.

Auto air outlet selectionHeating operation: When both lower and upper outlets operation and the Auto fan speed mode is selected, the lower outlet will be kept closed for twenty minutes after the start or until room temperature is close to reaching the set point. Then the air outlet will change to both outlets. That state will be maintained until the switch is turned off. Automatic adjustment of lower air outlet direction prevents stirring up of warm air and keeps optimum comfort at � oor level.

Cooling operation: When both lower and upper outlets operation is selected in Cooling or Dry operation, both outlets are kept open for sixty minutes after the start or until room temperature is below set point. Then the air outlet will change to the upper outlet. That state will be maintained until unit is switched off. In case both outlets operation with Auto fan speed mode is selected, the upper outlet will be kept closed for ten minutes after the start or until room temperature is close to reaching the set point. Then the air outlet will change to both outlets in order to spread comfort air to every corner.

Easy installation Piping and drain hose connection can be selected out of 6-directions.

Convenient to use operation Besides on/off operation, simultaneous lower and upper air outlets or upper outlet can be selected by the air � ow direction button. Further control can be selected on the remote control.

Convenient to use operation Besides on/off operation, simultaneous lower and upper air outlets or upper outlet can be selected by the air � ow direction button. Further control can be selected on the remote control.

SRF25ZJX-S, SRF35ZJX-S, SRF50ZJX-SSRF25~50ZJX

RC-E5RC-EX1A RCH-E3

Wired Remote Control Wireless Remote Control

RCN-TC-24W-ER

RC-E5RC-EX1A RCH-E3

Wired Remote Control Wireless Remote Control

RCN-TC-24W-ER

Page 17: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

PR

OD

UC

TS

17

Ceiling Concealed Type Medium Static.

Low profi le The height of FDUM50 model is only 280mm.

600mm drain pumpDrain can be discharged upwards by 600mm from the ceiling surface. It allows a piping layout with a high degree of freedom depending on the installation location.

Improved servicing Fan unit (impeller and motor) can be pulled out from the right side of the unit. Maintenance is available from the right side or from beneath.

FDUM50VF

RC-E5RC-EX1A

Wired

RCH-E3 RCN-KIT3-E

WirelessRemote control (Option)

280

Flexible hose

less than 600mm

FDUM50VF

RC-E5RC-EX1A

Wired

RCH-E3 RCN-KIT3-E

WirelessRemote control (Option)

280

Flexible hose

less than 600mm

RC-E5RC-EX1A RCH-E3

Wired Remote Control Wireless Remote Control

RCN-KIT3-E

RC-E5RC-EX1A RCH-E3

Wired Remote Control Wireless Remote Control

RCN-KIT3-EFDUM50VF

RC-E5RC-EX1A

Wired

RCH-E3 RCN-KIT3-E

WirelessRemote control (Option)

280

Flexible hose

less than 600mm

Maintenance hole

Pipe

Fan unitUnit

Service space

FDUM50VF

Page 18: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

MULTI series Air Conditioners 2013

18 Ceiling Suspended.

Wireless remote control

RCN-E-E

RC-E5

Wired remote control

RCH-E3

Wireless remote control

RCN-E-E

RC-E5

Wired remote control

RCH-E3

Rear

Right

Up

Height250mm

Rear

Right

Up

Height210mm

Easy installationIncreased freedom of a piping layoutThe refrigerant pipe from the unit can be arranged in three directions, rear, right and up. The drain pipe can be arranged in two directions, left and right. This will allow a free layout of piping for various installation conditions. The unit can only be serviced from below.

Compact and modern designAll models � t compactly on the ceiling. Height is 210mm. Elegant, modern design featuring rounded edges gives the room a comfortable atmosphere.

FDEN50VF

Page 19: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

19

PR

OD

UC

TS

Control Options.

Wired Remote Control Wireless Remote Option Super Link Network

Model Interface Wired Remote Control Infrared Kit Interface Wired Remote Control

SRK**ZJ-S

SC-BIKN-E

Options RC-EX1A RC-E5 RCH-E3

Not requiredSC-BIKN-E

SC-ADNA-EOptions RC-EX1A RC-E5 RCH-E3

SRK**ZJ-S1

SRK**ZJX-S

SRK**ZJX-S1

SRK71ZK-S

SRF**ZJX-S

SRF**ZJX-S1

SRR**ZJ-S

FDUM50VF

Not required

RCN-KIT3-E

SC-ADNA-EFDTC**VF RCN-TC-24W-ER

FDEN50VF RCN-E-E

CnT terminal is equipped

XR5

CnT

XR1~4 : DC12v XR5 : 220~240V

XR3

XR1

XR2

XR4

XR5

XR1

XR2

XR3

XR4

output1 (run)

output2 (heat)

output3 (comp on)

output4 (alarm)

common

Powersource

in put

Remote surveillance system

Card key on-off

HOTEL

HO

TE

L

Refrigerant Pipe Length Limit - The maximum piping length of the refrigerant pipes for the outdoor units, and the maximum

height difference for the outdoor units are as shown below.

length for one indoor unittotal length for all roomslower installation spot of the indoor unit (A)upper installation spot of the indoor unit (B)maximum height difference of the indoor units (C)precharged to refrigerant pipe length

heightdifference

under 25munder 70munder 20munder 20munder 25m

40m

B

A

C

SCM40ZJ-S SCM50/60ZJ-S SCM71/80ZJ-S

B

A

C

SCM100ZJ-S

under 25munder 30munder 15munder 15munder 25m

30m

under 25munder 40munder 15munder 15munder 25m

40m

SCM40ZJ SCM50/60ZJ SCM71/80ZJ

under 25munder munder munder munder m

m

under 25munder munder munder munder m

m

SCM100ZJ SCM125ZJ

B

A

C

B

A

CB

A

C

SCM125ZJ-S

Maximum refrigeration pipe run metres SCM40ZJ SCM50/60ZJ SCM71/80ZJ SCM100/125ZJ

length for one indoor unit 25

total length for all rooms 30 40 70 90

height difference

lower installation spot of the indoor unit (A)15 20

upper installation spot of the indoor unit (B)

maximum height difference of the indoor units (C) 25

pre charged to refrigerant pipe length 30 40 50

CnT terminal is equiped

Page 20: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

MULTI series Air Conditioners 2013

20 Inverter Multi-Split System.

Wall mounted type SRK Ceiling concealed type SRR 4way ceiling cassette type FDTC

Floor type SRF Ceiling suspended type FDEN

Duct connected type FDUMDuct connected type FDUM

SCM-ZJThe multi system allows a single outdoor unit to service up to six indoor units.

Individual refrigerant circuit for each indoor unit

Outdoor Unit

Floor type SRF

SCM40ZJ-S1 / SCM50ZJ-S1SCM60ZJ-S1 SCM71ZJ-S1 / SCM80ZJ-S1 SCM100ZJ-S1/ SCM125ZJ-S1

Page 21: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

PR

OD

UC

TS

21

SCM

40ZJ

-SSC

M50

ZJ-S

1SC

M60

ZJ-S

1SC

M71

ZJ-S

1SC

M80

ZJ-S

1SC

M10

0ZJ-

S1SC

M12

5ZJ-

S1

2 Ro

oms

2~3

Room

s2~

4 Ro

oms

4~5

Room

s4~

6 Ro

oms

Pow

er S

uppl

yOu

tdoo

r1

Phas

e 23

0V 5

0Hz

Rate

d Ca

paci

ty

Cool

ing

T1kW

4.0(

1.8~

5.9)

5.0(

1.8~

7.1)

6.0(

1.8~

7.5)

7.1(

1.8~

8.8)

8.0(

1.8~

9.2)

1012

.5

Heat

ing

H1kW

4.5(

1.4~

6.9)

6.0(

1.4~

7.5)

6.8(

1.5~

7.8)

8.6(

1.5~

9.4)

9.3(

1.5~

9.8)

1213

.5

Elec

tric

al In

put

Cool

ing

T1kW

0.84

1.

08

1.43

1.

74

2.16

2.

863.

9

Heat

ing

H1kW

0.90

1.

31

1.51

2.

00

2.26

2.

933.

25

EER

Cool

ing

T14.

76

4.63

4.

20

4.08

3.

70

3.5

3.21

COP

Heat

ing

H15.

00

4.58

4.

50

4.30

4.

12

4.1

4.15

Curr

ent

Cool

ing

T1A

3.7

4.7

6.5

7.6

9.4

12.4

17

Heat

ing

H1A

45.

86.

88.

810

12.8

14.1

Rec

Circ

uit B

reak

erA

25A

Soun

d Po

wer

Lev

el (J

IS C

9612

)Co

olin

g (O

utdo

or)

dB (A

)60

6263

6566

6869

Heat

ing

(Out

door

)dB

(A)

6265

6566

6671

72

Exte

rnal

Dim

ensi

ons

(HXW

XD)

mm

640X

850X

290

750X

880X

340

945X

970X

370

Net w

eigh

tOu

tdoo

rkg

4748

4962

92

Refr

iger

ant P

ipin

g

Liqu

id L

ine

mm

Ø6.3

5 X

2Ø6

.35

X 3

Ø6.3

5 X

3Ø6

.35

X 4

Ø6.3

5 X

4Ø6

.35

X 5

Ø6.3

5 X

6

Gas

Line

mm

Ø9.5

2 X

2Ø9

.52

X 3

Ø9.5

2 X

3Ø9

.52

X 4

Ø9.5

2 X

4Ø9

.52

X 5

Ø9.5

2 X

6

Unio

nm

m(Ø

9.52

Ø12

.7) X

1(Ø

9.52

Ø12

.7) X

2(Ø

9.52

Ø12

.7) X

2(Ø

9.52

Ø12

.7) X

2(Ø

9.52

Ø12

.7) X

2(Ø

9.52

Ø12

.7) X

2

Conn

ectio

n M

etho

dFl

are

conn

ectio

n

Refr

iger

ant R

410A

Volu

me

kg2.

02.

53.

156

Pre-

Char

ged

30 m

trs

40 m

trs

50 m

trs

Indo

or U

nit C

ombi

natio

n

SRK*

ZJS/

S1

kW

2.0,

2.5,

3.5

2.0,

2.5,

3.5,

5.0

2.0,

2.5,

3.5,

5.0

SRK*

ZJX

2.0,

2.5,

3.5

2.0,

2.5,

3.5

2.0,

2.5,

3.5

2.0,

2.5,

3.5

SRK*

ZJX-

S15.

05.

0,6.

05.

0,6.

0

SRK*

ZK-S

7.1

SRF*

ZJX

2.5,

3.5

2.5,

3.5

2.5,

3.5

SRF*

ZJX-

S15.

05.

05.

0

SRR*

ZJ2.

5,3.

52.

5,3.

5,5.

02.

5,3.

5,5.

0,6.

0

FDTC

*VD

2.5,

3.5

2.5,

3.5,

5.0

2.5,

3.5,

5.0,

6.0

FDUM

*VF

5.0

FDEN

*VF

5.0

Indo

or U

nit C

onne

ctio

n2

Units

2 to

3 U

nits

2 to

4 U

nits

4 to

5 U

nits

4 to

6 U

nits

Indo

or C

onne

ctio

n Ca

paci

tykW

4.0k

W to

6.0

kW4.

0kW

to 8

.5kW

4.0k

W to

11.

0kW

4.0k

W to

12.

6kW

4.0k

W to

13.

5kW

8.0

kW to

16k

W8.

0kW

to 1

9.5k

W

Note

s1

Rate

d da

ta is

mea

sure

d us

ing

SRK*

ZJX

indo

or u

nits

to m

atch

the

outd

oor u

nit c

apac

ity2

Curr

ently

ther

e is

no

ener

gy la

belli

ng s

tand

ard

for t

his

type

of p

rodu

ct

3 Th

e kW

out

put c

apac

ity, e

lect

rical

inpu

t, cu

rren

t and

reco

mm

ende

d ci

rcui

t bre

aker

are

indi

cate

d at

rate

d kW

out

put c

apac

ity. E

lect

rical

wor

k m

ust b

e ca

rrie

d ou

t by

a su

itabl

y qu

ali�

ed p

erso

n an

d co

mpl

y to

all

elec

tric

al

stan

dard

s an

d lo

cal r

egul

atio

ns.

Page 22: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

MULTI series Air Conditioners 2013

22 Multi System Indoor Unit.

Series

SPECIFICATIONSItem Model

Cooling capacityHeating capacity

Sound power level

Sound pressure level

kWkW

dB(A)dB(A)dB(A)dB(A)

l/s

mmkg

mmmm

CoolingHeatingCoolingHeatingCoolingHeating

Liquid lineGas line

2.53.15558

Hi:41 Me:31 Lo:22Hi:41 Me:34 Lo:27

208-150-83216-166-125

15

ø 6.35

SRK25ZJX-S3.54.55859

Hi:43 Me:33 Lo:22Hi:42 Me:35 Lo:27

225-158-83233-183-134

SRK35ZJX-S5.05.86062

Hi:47 Me:40 Lo:27Hi:48 Me:40 Lo:33

225-183-133275-241-175

SRK50ZJX-S6.06.86262

Hi:51 Me:41 Lo:29Hi:48 Me:41 Lo:34

241-208-141283-250-183

SRK60ZJX-S

ø 12.7

SRK20ZJX-S2.02.55354

Hi:39 Me:30 Lo:21Hi:38 Me:33 Lo:25

191-133-83200-158-116

SCM40~125ZJ-S1 SCM60~125ZJ-S1SCM50~125ZJ-S1

309X890X220

Allergen Clear Filter X 1, Photocatalytic Washable Deodorizing Filter X 1

ø 9.52

*

*

The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.

* Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.

Exterior dimensions (HXWXD)Net weightClean �lter

Piping

OUTDOOR UNITS TO BE COMBINED

Air �ow Indoor

FUNCTIONComfortable Functions

Comfortable Air Flow FunctionsAuto Flap Memory UP/DOWN Lateral

SwingAuto

Positioning of

installation

Others

RestartAutoBack-up

SwitchLuminous

24h ION

Maintenance & Prevention Functions

MC DiagnosticSelf Detachable

AllergenFilterAllergenFilterAllergenFilter

SUNFilterSUNFilterSUNFilter

Self CleanOperationSelf CleanOperationSelf CleanOperation

Convenient & Economy FunctionsOn Timer

24h TimerDRY

OFF Timer SleepEconomy

SRK-ZJXHigh COP wall mount type

SRR-ZJCeiling concealed type

SPECIFICATIONS

SRR25ZJ-S SRR35ZJ-S SRR50ZJ-S SRR60ZJ-SModel

Cooling capacityHeating capacity

Sound power level

Sound pressure level

Air �ow Q’ty (Hi)

Exterior dimensions(HXWXD)Net weight

Piping

OUTDOOR UNITS TO BE COMBINED

kWkW

dB(A)dB(A)dB(A)dB(A)

l/s

mmkg

mmmm

CoolingHeatingCoolingHeatingCoolingHeating

2.53.45455

Hi:40 Me:35 Lo:29Hi:41 Me:38 Lo:31

142167

3.54.55657

Hi:42 Me:37 Lo:30Hi:43 Me:40 Lo:32

150183

5.05.86060

Hi:48 Me:42 Lo:33Hi:48 Me:45 Lo:36

175217

6.06.86363

Hi:51 Me:44 Lo:35Hi:51 Me:47 Lo:38

208250

230x740x455

ø 6.35ø 9.52

23

SCM40~125ZJ-S1

*

*

ø 6.35ø 12.7

22

SCM60~125ZJ-S1SCM50~125ZJ-S1

Liquid lineGas line

FUNCTIONComfortable Functions Maintenance & Prevention Functions

MC DiagnosticSelfSelf Clean

OperationSelf CleanOperationSelf CleanOperation

Others

RestartAutoBack-up

SwitchLuminous

Convenient & Economy FunctionsOn Timer

24h TimerDRY

OFF Timer SleepEconomy

Page 23: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

PR

OD

UC

TS

23

Multi System Indoor Unit.

FUNCTIONComfortable Functions Convenient & Economy Functions

On Timer24h Timer

Economy

DRY

OFF Timer SleepOthers

RestartAutoBack-up

SwitchLuminous

Comfortable Air Flow FunctionsAuto Flap Memory UP/DOWN Air outlet

selection

Maintenance & Prevention Functions

MC DiagnosticSelf DetachableEnzyme

FilterEnzymeFilter

EnzymeFilter

SUNFilterSUNFilterSUNFilter

Self CleanOperationSelf CleanOperationSelf CleanOperation

SPECIFICATIONSModel

Cooling capacityHeating capacity

Sound power level

Sound pressure level

kWkW

dB(A)dB(A)dB(A)dB(A)

l/s

mmkg

mmmm

CoolingHeatingCoolingHeatingCoolingHeating

SRF35ZJX-S5.05.85858

Hi:46 Me:42 Lo:32Hi:47 Me:41 Lo:33

191-160-110200-166-126

SRF50ZJX-S3.54.55252

Hi:41 Me:34 Lo:28Hi:41 Me:36 Lo:31

153-130-106178-138-123

SRF25ZJX-S2.53.45151

Hi:40 Me:32 Lo:26Hi:40 Me:35 Lo:28

150-126-96175-136-110

Liquid lineGas line

600X860X23819

ø 6.35

*

*

The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.

* Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.

Natural Enzyme FilterX1 Photocatalytic Washable Deodorizing FilterX1

SCM40~125ZJ-S1 SCM50~125ZJ-S1

ø 9.52 ø 12.7

Exterior dimensions (HXWXD)Net weightClean �lter

Piping

OUTDOOR UNITS TO BE COMBINED

18

Air �ow Indoor

SRF-ZJXFloor type

SRK-ZJ-S1Wall mount type

Series

SPECIFICATIONSModel

Cooling capacityHeating capacity

Sound power level

Sound pressure level

kWkW

dB(A)dB(A)dB(A)dB(A)

l/s

mmkg

mmmm

CoolingHeatingCoolingHeatingCoolingHeating

Liquid lineGas line

2.53.25055

Hi:34 Me:28 Lo:21Hi:39 Me:31 Lo:24

131-100-83176-108-85

9.5

ø 6.35

SRK25ZJ-S/S13.54.05859

Hi:42 Me:32 Lo:22Hi:43 Me:37 Lo:25

168-106-83213-156-101

SRK35ZJ-S/S15.05.86161

Hi:46 Me:37 Lo:26Hi:45 Me:37 Lo:31

188-130-88225-170-125

SRK50ZJ-S/S1

ø 12.7

SRK20ZJ-S/S12.02.74952

Hi:33 Me:27 Lo:21Hi:36 Me:31 Lo:24

130-93-80163-105-83

SCM40~125ZJ-S1 SCM50~125ZJ-S1

294X798X229

Allergen Clear Filter X 1, Photocatalytic Washable Deodorizing Filter X 1

ø 9.52

*

*

Exterior dimensions (HXWXD)Net weightClean �lter

Piping

OUTDOOR UNITS TO BE COMBINED

Air �ow Indoor

FUNCTIONComfortable Functions

Comfortable Air Flow FunctionsAuto Flap Memory UP/DOWN Lateral

SwingAuto

Positioning of

installation

Others

RestartAutoBack-up

SwitchLuminous

Maintenance & Prevention Functions

MC DiagnosticSelf Detachable

AllergenFilterAllergenFilterAllergenFilter

SUNFilterSUNFilterSUNFilter

Self CleanOperationSelf CleanOperationSelf CleanOperation

Convenient & Economy FunctionsOn Timer

24h TimerDRY

OFF Timer SleepEconomy

Page 24: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

MULTI series Air Conditioners 2013

24 Inverter Multi Split System.

SRK-ZKWall mounted type

Series

SPECIFICATIONSItem Model

Nominal cooling capacityNominal heating capacity

Sound power level

Sound pressure level

kWkW

dB(A)dB(A)dB(A)dB(A)

CMM

mmkg

mmmm

CoolingHeatingCoolingHeatingCoolingHeating

SRK71ZK-S7.18.06061

Hi:49 Me:45 Lo:39 Ulo:26Hi:46 Me:43 Lo:38 Ulo:35

Hi:19.5 Me:17.5 Lo:14.0 Ulo:8.0Hi:21.5 Me:19.5 Lo:15.5 Ulo:14.0

318x1098x24815

Liquid lineGas line

Allergen Clear Filter x 1, Photocatalytic Washable Deodorizing Filter x 1 6.35 15.88

*

*

The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.

* Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.

Exterior dimensions (HXWXD)Net weightClean �lter

Piping

OUTDOOR UNITS TO BE COMBINED

Air �ow

FUNCTIONComfortable Functions

Others

RestartAutoBack-up

SwitchLuminous

Maintenance & Prevention Functions

MC DiagnosticSelf Detachable

Convenient & Economy FunctionsOn Timer

24h TimerDRY

OFF Timer SleepEconomy

AllergenFilterAllergenFilterAllergenFilter

SUNFilterSUNFilterSUNFilter

Self CleanOperationSelf CleanOperationSelf CleanOperation

Comfortable Air Flow FunctionsAuto Flap Memory UP/DOWN Lateral

Swing

Air Scroll24h ION

SCM100/125ZJ-S1

FDEN-VFCeiling suspended

FDEN50VFItem Model

Nominal cooling capacityNominal heating capacity

Sound pressure level

Air �ow

Exterior dimensions (HxWxD)Net weightAir �lter

Piping

OUTDOOR UNITS TO BE COMBINED

kWkW

dB(A)dB(A)CMMCMMmmkg

mmmm

CoolingHeatingCoolingHeating

5.05.8

Hi:39 Me:38 Lo:37Hi:39 Me:38 Lo:37Hi:11 Me:9 Lo:7Hi:11 Me:9 Lo:7

210x1070x69028

Pocket Plastic net x 2 (Washable)

*

The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.

* Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions. Powerful-Hi can be selected. Sound pressure level:Cooling dB(A):46 Heating:46, Air �ow:13CMM

6.3512.7

Liquid lineGas line

SPECIFICATIONS

FUNCTIONComfortable Functions Comfortable Air Flow Functions

Auto Flap Memory UP/DOWNOthers

RestartAutoBack-up

Switch

Maintenance & Prevention Functions

MC DiagnosticSelf

Convenient & Economy FunctionsOn Timer

24h TimerDRY

OFF Timer Sleep

SCM50~125ZJ-S1

RC-E5 RCH-E3

Wired Remote Control Wireless Remote Control

RCN-E-E

Page 25: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

PR

OD

UC

TS

25

Inverter Multi Split System.

FDTC-VF4way ceiling cassette type

FDTC25VF FDTC35VF FDTC50VF FDTC60VF

SPECIFICATIONS

Item Model

Nominal cooling capacityNominal heating capacity

Sound pressure level

Air �ow

Exterior dimensions(HXWXD)

Net weight

Piping

OUTDOOR UNITS TO BE COMBINED

kWkW

dB(A)dB(A)CMMCMMmmmmkgkg

mmmm

CoolingHeatingCoolingHeatingMain unitPanelMain unitPanelLiquid lineGas line

2.53.4

Hi:36 Me:32 Lo:29Hi:38 Me:33 Lo:29.5

Hi:9 Me:8 Lo:6.5Hi:9.5 Me:8.5 Lo:7

3.54.5

Hi:40 Me:36 Lo:30Hi:42 Me:35 Lo:32Hi:9.5 Me:9 Lo:7Hi:10 Me:9 Lo:8

5.05.8

Hi:42 Me:36 Lo:30Hi:42 Me:36 Lo:32Hi:11.5 Me:9 Lo:7Hi:11.5 Me:9 Lo:8

6.06.8

Hi:46 Me:39 Lo:30Hi:46 Me:39 Lo:32Hi:13.5 Me:10 Lo:7Hi:13.5 Me:10 Lo:8

248x570x57035x700x700

153.5

6.359.52

6.3512.7

*

The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.

* Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions. Powerful-Hi can be selected. Sound level dB(A):25VF(Cooling:38 Heating:39), 35VF(Cooling:41 Heating:43), 40/50/60VF(Cooling:47 Heating:47), Air �ow:25VF(Cooling:10 Heating:10.5), 35VF(Cooling:11 Heating:11.5), 50/60VF(Cooling:13.5 Heating:13.5)

FUNCTIONComfortable Functions Comfortable Air Flow Functions

Auto Flap Memory UP/DOWNOthers

RestartAutoBack-up

Switch

Maintenance & Prevention Functions

MC DiagnosticSelf

Convenient & Economy FunctionsOn Timer

24h TimerDRY

OFF Timer Sleep

Fits into standard 600 x 600 ceiling

SCM40~125ZJ-S1 SCM60~125ZJ-S1SCM50~125ZJ-S1

RC-E5RC-EX1A RCH-E3

Wired Remote Control Wireless Remote Control

RCN-TC-24W-ER

FDUM-VFDucted connected-low/middlestatic pressure

FDUM50VF

SPECIFICATIONS

Item Model

Nominal cooling capacityNominal heating capacity

Sound pressure level

Air �ow

Exterior dimensions (HxWxD)Net weightAir �lter

Piping

OUTDOOR UNITS TO BE COMBINED

kWkW

dB(A)dB(A)CMMCMMmmkg

mmmm

CoolingHeatingCoolingHeating

5.05.8

Hi:32 Me:29 Lo:26Hi:32 Me:29 Lo:26

Hi:10 Me:9 Lo:8Hi:10 Me:9 Lo:8

280x750x63529

Procure locally

*

The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.

* Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions. Powerful-Hi can be selected. Sound pressure level dB(A):Cooling:37 Heating:37, Air �ow:13CMM

6.3512.7

Liquid lineGas line

FUNCTIONComfortable Functions Others

RestartAutoBack-up

Switch

Maintenance & Prevention Functions

MC DiagnosticSelf

Convenient & Economy FunctionsOn Timer

24h TimerDRY

OFF Timer Sleep

Filter KITUM-FL1EF (option)

SCM50~125ZJ-S1

RC-E5RC-EX1A RCH-E3

Wired Remote Control Wireless Remote Control

RCN-KIT3-E

Page 26: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

MULTI series Air Conditioners 2013

26 Dimension Outdoor Unit. Models SCM40ZJ-S, 45ZJ-S

Symbol ContentA Service valve connection gas side 9.52 3 8" FlareB Service valve connection liquid side 6.35 1 4" FlareC Pipe cable draw-out holeD Drain discharge hole 20 x 3 places

secalp4x01MelohtlobrohcnAE

D

BAC

Service panel

Terminal block

E43

.5286.4

49.6

290

476203.1 510 136.9

1431

2.5

5012

13.5

340

640

15

850

100.3

42.7

124.1 34.6

2-16x12

211

42.7

2020

20

103.2

385.9 14.6

17.965

20

L1

L3Intake

No obstaclesService space

L2

Intake

Outlet

Minimum installation space

for electricalparts

100

600L2L3

L1

Examples of

100

Installation

Dimensions

Unit:mm

Models SCM71ZJ-S1, 80ZJ-S1

L1

L3Intake

L2

Intake

Outlet

100

600L2L3

L1

Examples of

100

Installation

Dimensions

Minimum installation space

DTerminal block

C

E

tnetnoClobmySA Service valve connection gas side 9.52 3 8" FlareB Service valve connection liquid side 6.35 1 4" FlareC Pipe cable draw-out holeD Drain discharge hole 20 x 3 places

secalp 4 x 01Meloh tlob rohcnAE

B

A

No obstaclesService space

for electricalparts

Unit:mm

1560

380

1941

8

73880150 580 150 26

340

2-R7.5

223

47.5

310

61

61

110.4

52

185 10

2475

0

214.4

5231

8.452

422.4

52

20

Model SCM125ZJ-S1

9.52 3 8" Flare

Content

C Pipe cable draw-out hole

D

E Anchor bolt hole

Drain discharge hole

Symbol

B

A Service valve connection gas side

M10 x 4places

20 x 3places

Service valve connection liquid side 6.35 1 4" Flare

L2L3

L1300150

OpenOpen150

500Open

3005

Examples of

Dimensions installation

L1

L3

Intake

Outlet

Intake

Minimum installation space

spaceService

L2

No obstaclesService space

for electricalparts

D580

76190

60

55

20

200

262.8 325

410

4037

040

20

Center of gravity

945

5211

5.2 219.2

5252

5252

531.2

427.2

323.2

5263

5.2

393

10

E

Center of gravity 26970

15 15

580

177

73

B

AC

Terminal block Rear panel

10170

Models SCM50ZJ-S1, 60ZJ-S1

Symbol ContentA Service valve connection gas side 9.52 3 8" FlareB Service valve connection liquid side 6.35 1 4" FlareC Pipe cable draw-out holeD Drain discharge hole 20 x 3 places

secalp 4 x 01Meloh tlob rohcnAE

D

BAC

Service panel

Terminal block

E

L1

L3Intake

L2

Intake

Outlet

100

600L2L3

L1

Examples of

100

Installation

Dimensions

Minimum installation space

No obstaclesService space

for electricalparts

Unit:mm

43.5

286.4

49.6

136.9

1431

2.5

5012

13.5

340

640

15 100.3

42.7

Model SCM100ZJ-S1

9.52 3 8" Flare

Content

C Pipe cable draw-out hole

D

E Anchor bolt hole

Drain discharge hole

Symbol

B

A Service valve connection gas side

M10 x 4places

20 x 3places

Service valve connection liquid side 6.35 1 4" Flare

L2L3

L1300150

OpenOpen150

500Open

3005

Examples of

Dimensions installation

L1

L3

Intake

Outlet

Intake

Minimum installation space

spaceService

L2

No obstaclesService space

for electricalparts

D580

76190

60

55

20

200

262.8 325

410

4037

040

20

Center of gravity

945

5211

5.2 219.2

5252

5252

531.2

427.2

323.239

3

10

E

Center of gravity970

15 15

177

2658073

B

AC

Terminal block Rear panel

10170

SCM40ZJ-S

SCM71ZJ-S1 SCM80ZJ-S1

SCM125ZJ-S1

SCM50ZJ-S1 SCM60ZJ-S1

SCM100ZJ-S1

Page 27: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

27

SP

EC

IFIC

ATIO

NS

Page 28: Inverter Multi-Split System Air Conditioners MHIAA is ......Variety of Indoor Units The indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette

Because of our policy of continuous improvement, we reserve the right to make changes in all speci� cations without notice. E&OE.

Australia: New Zealand: ABN 92 133 980 275 G.S.T. 105-673-620

Phone: 1300 138 007 Fax: 1800 644 329 Phone: 0800 138 007 Fax: 09 442 5346

NSW & Head Of� ce9C Commercial RoadKingsgrove NSW 2208PO Box 318 Kingsgrove NSW 1480

Victoria2/24 Lakeside DriveBurwood East VIC 3151

Queensland5/26 Flinders Parade North Lakes QLD 4509

Western AustraliaUnit 3A 2 Mulgul Rd Malaga WA 6090PO Box 667 Belmont WA 6104

AucklandUnit 2 100 Bush Road Albany 0632PO Box 300552 Albany 0632

www.mhiaa.com.au www.mhiaa.co.nz

MRE SPARE PARTS www.mrespareparts.com.au Tel: +61 (0) 2 9600 7444 Fax: +61 (0) 2 9600 8044

Our Air Conditioning & Refrigeration Systems Headquarters is an ISO9001 approved factory for residential air conditioners and commercial-use air conditioners (including heat pumps).

ISO9001

BIWAJIMA PLANT Mitsubishi Heavy Industries, Ltd.

Air-conditioning & Refrigeration Systems HeadquartersCerti�ed ISO 9001

Certi�cate number : JQA-0709

Our Air Conditioning & Refrigeration Systems Headquarters has been assessed and found to comply with the requirements of ISO14001.

ISO14001

BIWAJIMA PLANT Mitsubishi Heavy Industries, Ltd.

Air-conditioning & Refrigeration Systems HeadquartersCerti�ed ISO 14001

Certi�cate number : JQA-EM0256

MITSUBISHI HEAVY INDUSTRIES-MAHAJAK AIR CONDITIONERS CO., LTD.

Certi�ed ISO 9001Certi�cate Number : 04100 1998 0813

MITSUBISHI HEAVY INDUSTRIES-MAHAJAK AIR CONDITIONERS CO.,LTD.

Certi�cate Number : 04104 1998 0813 E5

ISO 14001Certi�cate 04104 1998 0813 E5

MH

IAA

306_

MU

LTI 1

2_20

12

Before starting use

Heating performanceThe heating performance values (kW) described in catalog are the values obtained by operating at an outdoor temperature of 7C and indoor temperature of 20C as set forth in the ISO Standards. As the heating performance decreases as the outdoor temperature drops, if the outdoor temperature is too low and the heating performance is insuf� cient, use other heating appliances as well.

Indication of sound valuesThe sound values are the values (A scale) measured in a chamber such as an anechoic chamber following the ISO Standards. In the actual installation state, the value is normally larger than the values given in the catalog due to the effect of surrounding noise and echo. Take this into consideration when installing.

Use in oil atmosphereAvoid installing this unit in as atmosphere where oil scatters or builds up, such as in a kitchen or machine factory. If the oil adheres to the heat exchanger, the heat exchanging performance will drop, mist may be generated, and the synthetic resin parts may deform and break.

Use in acidic or alkaline atmosphereIf this unit is used in acidic atmosphere such as hot spring areas having high level of sulfuric gases or in alkaline atmosphere including ammonia or calcium chloride, places where the exhaust of the heat exchanger is sucked in, or at coastal areas where the unit is subject to salt breezes, the outer plate or heat exchanger, etc., will corrode. Please ask a dealer or specialist when you use an air conditioner in places differing from a general atmosphere.

Use in places with high ceilingsIf the ceiling is high, install a circulator to improve the heat and air � ow distribution when heating.

Refrigerant leakageThe refrigerant (R410A) used for Air conditioner is non-toxic and non� ammable in its original state. However, in consideration of a state where the refrigerant leaks into the room, measures against refrigerant leaks must be taken in small rooms where the tolerable level could be exceeded. Take measures by installing ventilation devices, etc.

Use in snowy areasTake the following measures when installing the outdoor unit in snowy areas.

Snow preventionInstall a snow-prevention hood so that the snow does not obstruct the air intake port or enter and freeze in the outdoor unit.

Snow pilingIn areas with heavy snow fall, the piled snow could block the air intake port. In this case, a frame that is 50cm or higher than the estimated snow fall must be installed underneath the outdoor unit.

Automatic defrosting deviceIf the temperature is low, and the humidity is high, frost will stick to the heat exchanger of the outdoor unit. If use is continued, the heating performance will drop. The “Automatic defrosting device” will function to remove this frost. After heating for approx, three to ten minutes, it will stop, and the frost will be removed. After defrosting, hot air will be blown again.

Servicing the air-conditionerAfter the air-conditioner is used for several seasons, dirt will build up in the air-conditioner causing the performance to drop. In addition to regular servicing, we recommend the maintenance contract (charged for) by a specialist.

Safety PrecautionsAir-conditioner usage targetThe air-conditioner described in this catalog is a dedicated cooling/heating device for human use. Do not use it for special applications such as the storage of foodstuffs, animals or plants, computer server rooms, precision devices or valuable art, etc. This could cause the quality of the items to drop, etc. Do not use this for cooling vehicles or ships. Water leakage or current leaks could occur.

Before useAlways read the “User,s Manual” thoroughly before starting use.

InstallationAlways commission the installation to a dealer or specialist. Improper installation will lead to water leakage, electric shocks and � res. Make sure that the outdoor unit is stable in installation. Fix the unit to stable base.

Usage placeDo not install in places where combustible gas could leak or where there are sparks. Installation in a place where combustible gas could be generated, � ow or accumulate, or places containing carbon � bers could lead to � res.

Only persons that are quali� ed and licensed are permitted to install and service products that contain refrigerants in Australia, go to www.arctick.org. Suitable access for service must be provided in compliance with industry standards and local regulations.

MHIAA is proudly sponsoring Monika’s Doggie Rescue