35
Ion Beam Analysis Ion Beam Analysis Today and Tomorrow Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

Embed Size (px)

Citation preview

Page 1: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

Ion Beam Analysis Today Ion Beam Analysis Today and Tomorrowand Tomorrow

Ferenc PásztiResearch Institute for Particle and Nuclear

Physics, Budapest

20+5 min

Page 2: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min
Page 3: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

• Accelerators

- Used ones (5 MeV VdG, …)

- Smaller and cheaper (200 keV FIB, …)

- Special designs (3 MeV Tandem)• Radioactive sources (planetary research)• Beam size

- Normal (1x1 mm2)

- Microbeam (1x1 m2)

The incident beam

Page 4: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

5 MeV Van de Graaff Accelerator (EG-2R) at RIPNP, Budapest

Page 5: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

1MeV tandem at Cambridge (GC¯AMS)

B. J. Hughey, Nucl. Instr. Meth. B 172 (2000) 40.

Page 6: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

http://www.culture.gouv.fr/culture/conservation/fr/methodes/aglae.htm

2MeV Tandem at Louvre Paris (AGLAE)

Page 7: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

RBSRBS

Page 8: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

• Elements heavier than the ion

Isotopes for light elements • Depth of analysis few 100nm (few m) • Depth resolution few 10nm (few Å) • Sensitivity few at% (light) -

few 100 ppm (heavy)

Main parameters

Page 9: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

RBS spectra (3.045 MeV 4He) of Co implanted Si and a porous Si.

Channel Number

200 300 400 500 600 7000

250

500

750

1000

1250

1500

O

Si

Co

b)

RT LT

Yie

ld (

coun

ts/c

h.)

Channel number

100 200 300 400 5000

500

1000

1500

2000

2500

3000

3500

a)

Si in porous Si

O in porous SiO in buried SiO

x

O resonance peak at the surface

Background

SiO

x

buri

ed

SiP

orou

s

SiPur

e

CoS

i 2

Si in buried SiOx

Si in pure Si

Si in CoSi2

Co in CoSi2

Si PS

Yie

ld (

coun

ts/c

h.)

A.R.Ramos, Nucl. Instr. Meth. B 178 (2001) 283.

Page 10: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

ERDERD

Page 11: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

• Absorber foil• Kinematics • Coincidence • Element identification (E-E, TOF-E,

ExB…)• …

Suppressing the scattered ions

Page 12: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

• Elements Lighter than the ion Isotopes for light elements• Depth of analysis few 100nm• Depth resolution few 10nm (few nm) • Sensitivity few 0.1% (few ppm)

Main parameters

Page 13: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

J. Russel, Mat. Sci. Eng. R 38 (2002) 107.

ERD spectrum from a thin, 200 Å, deuterated polystyrene film

Page 14: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

H. Timmers, Nucl. Instr. Meth. B 190 (2002) 393.

2D ERD spectra from a GaN film with impurities (200 MeV Au ions, E-E gas detector)

Page 15: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

NRANRA

Page 16: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

• Ions (p, d, , …)

Positive Q value, filter foil• n or

Special detectors

Suppressing the scattered ions

Page 17: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

• Elements specific

Isotopes specific• Depth of analysis few 10nm - few m• Depth resolution few nm - few m - ∞• Sensitivity few ppm

Main parameters

Page 18: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

M.E.Varela, Geochimica et Cosmochimica Acta 64 (2000) 3433

12C(d,p)13C NRA spectra of olivine with 1000 ppm C content (1.45 MeV d, 9 m Al filter foil)

Page 19: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

PIXEPIXE

Page 20: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

• Elements heavier

Isotopes no• Depth of analysis few m• Depth resolution no• Sensitivity few % - few 10 ppm

Main parameters

Page 21: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

S.B. Reddy, Nucl. Instr. Meth. B in print

PIXE spectra taken from tissues of thyroid

NormalAdenoma

Cancer

Page 22: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

ChannelingChanneling

Page 23: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

Basic principle of channeling

Page 24: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

A. Manuaba, Nucl. Instr. Meth. B (2001) 63

Channeling RBS spectra of He and N-implanted and annealed Si. Virgin and random spectra are also included.

(1016 ion/cm2 units)

Page 25: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

E. Alves, Nucl. Instr. Meth. B 106 (1995) 429

Lattice localization of Er in sapphire by RBS/channeling

Page 26: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

MicroprobeMicroprobe

Page 27: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

J. Tajima, Nucl. Instr. Meth. B 181 (2001) 44.

Schematic diagram of the 200 kV FIB microprobe at Osaka University. 80 nm lateral resolution, Si, Be Au ions.

Page 28: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

Y.K. Park, Nucl. Instr. Meth. B 158 (1999) 487.

Secondary electron and RBS mapping images by the FIB

microprobe.

300 keV Be2+

Page 29: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

FutureFuture

Page 30: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

New accelerators for IBA

• Cheaper and smaller accelerators for routine applications• Larger used machines (HI-ERDA) • Better microprobes •Transportable IBA?

Page 31: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

Unique features

• Channeling for damage profiling and lattice localization• H depth profiling• Atomic depth resolution• Extreme sensitivity

Page 32: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

New methods appear• Pore structure determination by resonance method• Combination of TOF-RBS and TOF-SIMS by a

nanoprobe• …

Page 33: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

F. Pászti, Vacuum. 50 (1998) 451.

R-BS spectra on columnar porous Si (3045+100 keV 4He+). The peak is due to 16O(,) resonance.

At tilt 0° the beam is parallel to the pores.

Page 34: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

F. Pászti, Nucl. Instr. Meth. B 161-163 (2000) 963.

Half-width of the resonance peak for samples implanted at various tilts and fluencies.

Solid lines are fitted Lorentzian curves.

Page 35: Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

K. Iwasaki, Nucl. Instr. Meth. B 190 (2002) 296.

TOF spectra by the 200keV FIB. H, O, C peaks are due to secondary ions accelerated by the 1.8 kV

detector bias of the MCP (TOF-SIMS).

As implanted SiO2

As implanted Si

25 nm Au on Si

200 keV Si2+