Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
EquipmEnt ● SErvicE ● SolutionS
Locations Alabama ● California ● Colorado ● Florida ● Georgia ● Illinois Nevada ● New Mexico ● Pennsylvania ● Texas ● Utah
FIRST IN SERVICE
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
loc
atio
nS
1 LocationsTPR FiRsT in seRvice
Southern Region California Los Angeles 800-821-4478 North Los Angeles 877-246-4087 Ventura / Santa Barbara 855-834-9058 Orange County 800-772-8004 Inland Empire 877-246-4085 San Diego 800-350-7528
Rockies Region Colorado Denver 303-287-2264 Colorado Springs 719-633-4556 Berthoud 970-532-4066 Grand Junction 970-523-8520 New Mexico Albuquerque 505-881-4830 Utah Provo 801-356-0100 Salt Lake City 801-265-1366
Eastern Region Alabama Birmingham 205-956-1668 Florida Jacksonville 904-786-4100 Miami 844-724-4446 Orlando 888-777-8307 Tampa 844-724-4445 Georgia Atlanta / West 404-505-0510 Atlanta / North 707-932-2165 Atlanta 866-260-8609 Illinois Chicago 800-220-8707 Pennsylvania Pittsburgh 412-331-8118
TPR Traffic Solutions California Los Angeles / Orange Co. 866-537-1260 Inland Empire 855-326-5953 San Diego 833-758-7660 San Leandro 855-351-1114 Nevada Las Vegas 877-809-6493
Traffic Control Speciality Locations
Northern Region California San Francisco N. Bay Area 800-321-5550 San Francisco S. Bay Area 877-246-4086 Sacramento 800-548-0688 Fresno - Central Valley 844-803-8408 Nevada Reno 877-809-6492 Las Vegas 877-809-6493
Texas Region Texas Dallas / Ft. Worth 817-502-1444 Houston 866-247-9449 San Antonio 866-501-8955
TRENCH PLATE® RENTAL CO www.TPRco.com
contents 2rev.10/2019
Locations / Contents 1-2
Trench Boxes Steel Trench Box 3-4
Manhole Boxes 5-6
Panel Shield 7Light Duty Steel Box 8Aluminum Quik Box 9-10
Ultra Shore 11-12
Build A Box 13
Steel Plate Steel Plate 14
Slide Rail System Slide Rail System 15-16
Guide Frame 17
Beams & Overlap H-Pile & Wide Flange Beam / Over-Lap Sheeting 18
Shoring Aluminum Hydraulic Shore 19
High Clearance / Horizontal Waler 20
Pumps / Rock & Finger Guard 21
Trench End Brace 22
Double Cylinder Power Shore / Screw Jack 23
3” Steel Cylinder Power Strut / Quadra Brace 24
Fall Arrest Fall Arrest 25
Tripod / Winch / Harness 26
Davit Arm / Stanchion 27
Trench Bridge / Portable Road Bridge 28
Confined Space Confined Space 29
Ventilation Equipment 30
Hazardous Atmosphere 31
Portable Gas Detector 32
Traffic Control K-Rail / Water Filled Barrier 33
Flashing Beacon Light / Message Boards 34
Additional Products Rock Screen / Bedding Container 35
Pipe Roller / Pipe Puller 36
Pipe Plug / Leak Locator 37
Pipe Deflection Gauge / Mechanical Pipe Plug 38
Training Competent Person Training / Confined Space 39
Shoring / Sloping & Benching 40
Excavation Safety 41Metric Conversion 42
TPR FiRsT in seRvice
co
ntEn
tS
Trench Plate® Rental Co has the solution no matter what your application. We have a complete inventory of Trench Boxes ranging from lightweight boxes for utility and general maintenance, to large boxes in 4, 6, and 8 inch thick walls designed for the deepest toughest projects.
Features: ● High strength steel construction● 4 lifting points built into sidewalls ● Pulling Eyes ● Adjustable and Stackable ● Compressed wood in top horizontal to limit bucket damage● Bottom horizontal protected by steel drag plate
Deep ApplicationsSteel Trench Box
TPR FiRsT in seR"vice3
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
Arch Spreaders
StEE
l tr
Enc
h B
ox
steeL trench Box
Bore Pits
Our customers safely meet their deadlines using our knowledge and abilities to maximize productivity and safety.
Optional features:
● Fall Protection Guard Rails ● Wheel Kit● Box Walkway● Pulling Tongue● Grade Plate
Steel Box Walkway
Box Size H x L
Pipe Clearance
Approx. Wt.
4 x 8 21" 2,3458 x 8 64" 4,100
4 x 10 21" 3,4716 x 10 41" 4,2808 x 10 64" 5,100
10 x 10 85" 5,8004 x 12 21" 4,0406 x 12 41" 5,2508 x 12 64" 6,600
10 x 12 85" 8,4004 x 16 21" 4,8006 x 16 41" 6,5208 x 16 64" 7,830
10 x 16 85" 9,6504 x 20 21" 5,7006 x 20 41" 8,2508 x 20 64" 9,690
10 x 20 85" 11,4904 x 24 21" 6,9806 x 24 41" 8,8008 x 24 64" 11,330
10 x 24 85" 14,0704 x 28 21" 9,6006 x 28 41" 12,5708 x 28 64" 16,430
10 x 28 85" 19,5504 x 32 21" 12,1006 x 32 41" 16,050
10 x 32 85" 25,3355”X5” Square Spreaders 25 lbs. per ft 8” Round Spreaders 50 lbs. per ft
Custom Sizes and Modifications Available Specifications May Vary
TPR FiRsT in seRvice4
TRENCH PLATE® RENTAL CO www.TPRco.com
Guard Rails fit on Trench Shields, Manhole Boxes and our Slide Rail System.
Guard Rails
StEEl t
rEn
ch B
ox
steeL trench Box
TPR FiRsT in seRvice
Box Size Double Wall Door Size Approx. Wt.
4H x 8L x 8W 2" 2,4304H x 10L x 10W 3" 3,5806H x 10L x 10W 3" 48"H x 48"W 5,1108H x 10L x 10W 3" 48"H x 48"W 5,9004H x 12L x 12W 3" 3,7306H x 12L x 12W 3" 48"H x 48"W 4,9808H x 12L x 12W 3" 48"H x 48"W 6,740
Two Piece Manhole Boxes are versatile and accommodate a wide range of excavation sizes. Variable end openings allow larger cross connections. They can be used with spreaders up to 8 long, creating end openings up to 8 wide and 6 tall or up to 8 tall with the use of legs.
● Large 48” doors on the solid wall. ● Stackable for greater depth.
Boxes expand hydraulically to allow adjustments for excavation and manhole size.
Boxes can be stacked and multiple boxes can be placed in the excavation as a unit.
► Hydraulic Manhole BoxHydraulic Manhole Box
Size Approx. Lbs.
4H x 8L 1,200
8H x 8L 2,000
5tw
o p
iEc
E m
an
ho
lE B
ox
two Piece ManhoLe Box Quik-Shor®
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
TPR FiRsT in seRvice
● High strength steel construction.
● Easy connecting pins and keepers for quick stacking.
● Large doors allow cross connection of larger pipe.
● Box interiors are painted white to illuminate the working area.
6
TRENCH PLATE® RENTAL CO www.TPRco.com
ma
nh
olE B
ox
ManhoLe Box Quik-Shor®
Box Size Door Size Style Approx. Wt.4'H x 8'L x 8'W Single Wall 1,4628'H x 8'L x 8'W 27"H x 36"W Single Wall 4,3504'H x 8'L x 8'W Double Wall 2,4058'H x 8'L x 8'W 40"H x 40"W Double Wall 4,8704'H x 10'L x 10'W Double Wall 3,2806'H x 10'L x 10'W 48"H x 48"W Double Wall 4,6708'H x 10'L x 10'W 48"H x 48"W Double Wall 6,180
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
TPR FiRsT in seRvice7
alu
min
um p
an
El S
hiE
ldaLuMinuM PaneL shieLd
Aluminum Panel Shields are a smooth wall, welded aluminum trench shield. They are modular and can be configured in a variety of ways to accommodate different trench end conditions and pipe clearances. Both static and hydraulic pressurized applications are available.
Box Size
4 x 64 x 88 x 8
2 x 104 x 106 x 108 x 104 x 126 x 128 x 128 x 14
Hyd. Strut
52" - 88" 70" - 108" 85" - 120" 108" - 144"
TRENCH PLATE® RENTAL CO www.TPRco.com
TPR FiRsT in seRvice8
Light Duty Steel Boxes are specifically designed for municipalities and utility contractors for the installation, repair and maintenance of water, sewer, and gas lines, electrical & communication vaults. Projects where rubber tire backhoes and small excavators are used.
lig
ht d
uty S
tEEl tr
Enc
h Bo
x Light duty steeL trench Box
Light Duty Steel BoxSize PSF Depth in
C-60 SoilApprox.
Wt.4 x 14 1500 25 ft. 3,0606 x 14 1500 25 ft. 4,2904 x 16 1200 19 ft. 3,5206 x 16 1140 19 ft. 4,8454 x 18 960 15 ft. 3,8806 x 18 960 15 ft. 5,2804 x 22 740 16 ft. 5,6656 x 22 1114 17 ft. 7,432
TPR FiRsT in seRvice9
alu
min
um q
uik
-Bo
xaLuMinuM Quik-Box® Quik-Shor®
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
Aluminum Quik-Boxes are manufactured by Quik-Shor® and make the perfect box for smaller projects where only a small excavator or rubber-tire backhoe is available.
Quik-Boxes are able to safely shore up to 20 feet in depth and easily allow for cross connections by use of the side doors.
● Hydraulic struts allow variable width
● Return springs protected by steel sleeves
● Light weight / Can be moved and installed by a rubber-tire backhoe ● Easily positioned
● Can be set up for three or four sided applications
● Boxes are stackable for greater depth
Variable Width
TPR FiRsT in seRvice10
TRENCH PLATE® RENTAL CO www.TPRco.com
alu
min
um q
uik-B
ox
® aLuMinuM Quik-Box® Quik-Shor®
Aluminum Quik-Box®
Size Approx. Wt.
6 x 6 1,4006 x 8 1,5008 x 8 1,600
6 x 10 1,7008 x 10 1,900
10 x 10 2,8006 x 12 1,9008 x 12 2,0006 x 14 2,400
6 x 16 2,800PSF rating varies based on configuration,
see tabulated data
► Gas Power Pump
Quik-Shor®s Power Pump makes the installation and removal of Hydraulic Boxes and Shores faster.
Hydraulic Strut Sizes29" - 43" 47″ - 77"35" - 53" 53" - 89"41" - 62" 75" - 117"
ult
ra S
ho
rE
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
11 ultrashoreTPR FiRsT in seRvice
UltraSHORE panels are made of a specially corrugated aluminum that gives protection in trenches up to 12 feet deep, but weighs hundreds of pounds less than other shoring products. Stack two or more UltraSHORE panels or use them vertically, standing on end, in any combination. Special options such as wheel kits and legs let you take full advantage of O.S.H.A. regulations.
Ultra Versatile ● All panels can be used horizontally or vertically ● All panels are stackable ● Close off one or both ends with quik-release spring-loaded end closure panels Ultra Light ● One person can lower a single pair of assembled panels into an excavation● Two people can lower a stacked assembly of two panels into an excavation Ultra Convenient ● Transport assembled or broken in the smallest pick up
Ultra Safe● Bury depth to 12 feet, even in Class “C” soils
NOTE: The ultra Shield standard panels are not meant for severe duty applications(not to exceed 75 psf) without factory modifications. *Soil classification incompliance with OSHA rules and regulations.
Model Size HxL PSF Rating
Weight Per Pair
Bury Depth
S24-60 24″ x 60″ 1600 74 lbs 12 ftS24-84 24″ x 84″ 1600 96 lbs 12 ft
S48-60 48″ x 60″ 1100 130 lbs 12 ft
S48-84 48″ x 84″ 950 160 lbs 12 ft
S48-120 48″ x 120″ 865 260 lbs 12 ft
S48-144 48″ x 144″ 620 300 lbs 12 ft
Installation can be a one man job
S48-84 Panels
ultrashore u
ltra S
ho
rE
TRENCH PLATE® RENTAL CO www.TPRco.com
12TPR FiRsT in seRvice
UltraSHORE - Lightweight Aluminum Trench Shields
3. Standing in the middle of the box, bring the two panels to a parallel position, leaning slightly at opposing angles.
2. Pick up second panel by top edge and bring to near vertical position.
1. Mount spreaders in one panel and prop up. Lay the second panel on the ground, collars up.
4. Insert spreaders into collars one at a time.
5. Lift up on middle handles spreaders will seat themselves properly. Pin all remaining collars.Options
● Wheel Kits with Axle - Widths: 60", 72" and Custom ● End Closure Panels Available Sizes: 48" x 24", 48" x 36", 48" x 48", 48" x 60" ● Lifting Harness ● Stacking Accessories ● Custom Designs for Special User Applications
ASSEMBLES IN MINUTES
Spreader Options Standard Spreaders
20″ 3 lbs24″ 3.6 lbs30″ 4.5 lbs42″ 6.5 lbs54″ 8 lbs
Spreader Options Adjustable Spreaders
20″ to 26″ 8 lbs30″ to 42″ 12 lbs40″ to 54″ 16 lbs
Custom cut to length up to 12 ft.
Custom cut to length 54" to 96"
Add 4" to determine outside shield dimension. Example: 20" spreaders allow shield installation in a 24" cut.
TPR FiRsT in seRvice13
Bu
ild a
Bo
x BuiLd a Box
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
The MOD Series is a modular Aluminum Trench Shield system that is lightweight and easily transported via pickup truck. It can be used as a 2-, 3- or 4-sided system with existing components and can be changed on the fly at a job site to meet the jobs requirements.
Options:
● Wheel kits● Adjustable legs● Lifting eyes● Stacking units● Custom sizes
Quick and Easy Assembly
Begin assembling the shield, two corner end-posts are pinned to side panels and rear panel
Side and rear panels are stacked to desired height
Corner end-posts are pinned in place
Shield is easily handled by a rubber-tired backhoe loader
Adjustable spreaders pin in place to complete a 3-sided shield
Step One
Step Two
Step Three
Step Four
Final Step
With the MOD Series you can omit its bottom panels, for use on projects that involve T-connections and/or crossing utilities, when soil conditions permit.
Lightweight 2-foot high aluminum panels are easily unloaded from a pickup truck by hand without the use of machines. No lifting equipment is needed.
TPR FiRsT in seRvice14
StEEl p
latE steeL PLate
TRENCH PLATE® RENTAL CO www.TPRco.com
◄ SKID RESISTANT PLATE ►
Temp. Manhole Rounds
Size Lbs.36” 12042” 18048” 250
Curb PlateSize Thick Lbs.
3 x 10 1” 1,250
Rock PlateSize Thick Lbs.
8 x 10 1" 3,750 Rock Plates are a low cost, portable system designed to be placed at the exits of construction sites.
► Rock Plate
PLATES AVAILABLE WITH EYEBOLTS FOR EASE OF MOVEMENT
Steel Plate Sizes
Size Thickness Weight
4 x 4 1" 6544 x 5 ¾" 6134 x 6 1" 9804 x 8 1" 1,3074 x 10 1" 1,6344 x 20 1" 3,2675 x 10 1" 2,0425 x 15 1" 3,0636 x 8 1" 1,9606 x 10 1" 2,4506 x 12 1" 2,9406 x 20 1" 4,9008 x 10 1" 3,2678 x 12 1" 3,9218 x 15 1" 4,9018 x 16 1" 5,2278 x 20 1" 6,5346 x 12 1½" 4,4118 x 12 1½" 5,8808 x 15 1½" 7,3518 x 20 1½" 9,8028 x 20 2" 13,068
Slide Rail Systems are made up of steel panels, which are similar to the sidewalls of a trench box, and vertical steel posts. The panels slide into the posts, creating a two, three or four-sided configuration. Using a “dig and push” method of installation, the panels and posts are pushed gradually into the pit as the site is being excavated. Because the Slide Rail System is installed gradually in concert with the progress of the excavation preventing trench wall loss.
TPR FiRsT in seRvice
Slide Rail Components offer the option of using lighter equipment when installing the system. The cost of rental and installation of the system is approximately 50 percent of steel sheeting. One of the biggest advantages of Slide Rail is that installation of the system and the excavation are completed together, saving time and reducing cost.
Standard 4-Sided Pit
15
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
Slid
E r
ail S
yStE
msLide raiL
Typical Plan
Slide Rail Systems have proven to be a highly adaptable shoring system. Having the ability to provide open pits and trench depths of up to 30 feet, and huge spans without the use of Walers.
Save 30% TO 60% off conventional sheeting.
Great for pipelines.
Second to none in pit applications.
Can be installed by a small crew and an excavator (No Drill Rig required).
Flexibility of components – almost any size and configuration is possible.
Utility crossings are easy to accommodate.
Larger cantilever means large structures or pipe can be accommodated.
Multiple operations can be performed simultaneously, creating greater productivity.
TPR FiRsT in seRvice
The second type is a LINEAR Multi-Bay System which has open ends on the trench and does notuse corner posts. This configuration is idealfor installing long pipelines, even over great distances. The open ends allow contractors to install pipe in the front bay, while back-filling in the back bay and “leapfrogging” the system forward.
4-Sided Multi- Bay Multi-Bay Systems: the first is a 4-SIDED Multi-Bay system which uses corner-posts and panels to enclose the ends of the Multi-Bay system. 4-sided Multi-Bay systems are ideal for tankinstallation, long structures, or increasingly more popular: microtunneling and other types of boring operations.
Linear Multi- Bay
16
TRENCH PLATE® RENTAL CO www.TPRco.com
Slid
E ra
il SyStEm
sLide raiL
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
17 guide FraMe TPR FiRsT in seRvice
gu
idE
Fra
mE
The Quicksheet Guideframe from Trench Plate Rental is a special shoring solution for excavations with crossing service lines or unusual encumbrances.
Quicksheet is assembled and inserted as a complete unit into a pre-excavated trench. KD-6 overlapping sheet pile is inserted into the frame and driven to grade; creating a two, three, or four-sided shored area. The pit or trench can then be excavated while protecting the excavation walls.
The configuration of the guide frame system is adaptable, allowing for a wide variety of excavation sizes, differing elevations, or crossing utilities. Sheeting caps are used to protect the top of the sheets, as well as to allow for a larger pad to push the sheet into position.
Sheeting caps are used to protect the top of the sheets, as well as to allow for a larger pad to push the sheet into position.
TPR FiRsT in seRvice
Beam Sizes
10", 12", 14"
Strong, durable high strength steel sheets.
Ideal for use as shoring and bulk heading ends of trench shields, or anywhere that locking sheets are not required.
Overlap design allows for easy installation with less damage.
► Overlap Sheeting
► Beam & Plate
TRENCH PLATE® RENTAL CO www.TPRco.com
Beam and Plate systems offer large free span work areas. Beams are driven into the ground and steel plates are placed inside the flanges of the beams creating a safe work area. Beam and Plate systems require design by a Registered Professional Engineer.
► H Pile & Wide Flange Beam
h-p
ilE wid
E ● Fla
ng
E BEa
m h-PiLe ● wide FLange BeaM 18
TPR FiRsT in seRvice
Rail Lengths 2, 3½, 5, 7, 9, 12, 16, 20, 24
Cylinder Sizes17" - 27"
22" - 36"
28" - 46"
34" - 55"
46" - 82"
52" - 88"
70" - 106"
88" - 124"
106" - 142"
124" - 160"
142" - 178"
Pre-Assembled, Pre-Engineered vertical shoring systems are quick and easy. Because they are light-weight, most shores can be handled by a single person, thus increasing productivity. The fact is in most situations, you can shore a trench as fast as your excavator can open the trench. Quik-Shor aluminum hydraulic shoring can be easily installed from above ground, keeping workers out of unprotected trenches.
Over- sleeve protection for Cylinders.
Finger Guards help eliminate hand and finger injury.
Rock Guards improve productivity and reduce shore damage.
Easily transported.
Portable hand pump and power pump use biodegradable shoring fluid.
Installation and removal tools.
19v
Erti
ca
l a
lum
inu
m S
ho
rES
VerticaL aLuMinuM shoring Quik-Shor®
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
TPR FiRsT in seRvice
Operating Widths
25" - 38"30" - 48"36" - 57"42" - 72"48" - 84"70" - 112"
Rail Lengths 8, 10, 12, 16
Waler Lengths 6, 8, 10, 12, 16
Operating Widths
25" - 38"30" - 48"36" - 57"42" - 72"48" - 84"70" - 112"
Walers are another creative way to shore an excavation. These systems are adaptable for crossing utilities.
An excellent light weight system.
Provides more working space.
All Walers can be installed from above ground.
Great for close sheeting job conditions.
Portable hand pump uses biodegradable shoring fluid.
Cylinder Extension Kits.
► Aluminum Walers with Steel Struts
20
TRENCH PLATE® RENTAL CO www.TPRco.com
hig
h clEa
ra
nc
E Sh
or
ES ● wa
lErS
high cLearance shoring ● waLers Quik-Shor®
High Clearance Shores with Steel Struts are a must for your projects where pipe clearance is a factor.
Ideal for BIG PIPE projects 410" Clearance from the bottom rail. Up to 611" of clearance in A or B soils.
► High Clearance Shores
TPR FiRsT in seRvice
► Quik–Pump®
An Auto Shifting Multi Stage Pump Dramatically reduces (up to 60%) the number of strokes required to bring a shore to pressure.
► Finger GuardsFinger guards protect your employees from getting pinched fingers. These guards have proven themselves in millions of uses insuring the safest work environment for your employees.
► Electric Power Pump 2 button remote hand control.Fold down handles / Flat proof rubber tires.Maintenance free sealed AGM battery & charger.Easy clean filter.Low power consuming motor on high pressure pump.High impact plastic storage box.Balanced 2 wheel powder coated frame. Quick Reference Guide.
► Rock GuardsDeveloped to prevent back-fill (Rocks) becoming lodged behind the cylinder block. Also acts to provide protection against pinched fingers.
21
► Gas Power PumpAnother Quik-Shor exclusive. Developed for all 3 inch steel cylinder products. Color-coded hoses from pump to strut. Color-coded manifold.
pum
pS ●
ro
ck &
Fin
gEr
gu
ar
dS
PuMPs ● rock & Finger guards Quik-Shor®
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
TPR FiRsT in seRvice
Quik-Shor® has developed a close sheeting shore for the end of trenches.
End Braces can be used in conjunction with any other shoring system fromhydraulic shores to boxes.
Trench End Braces can be kept up to 2 foot from the bottom of excavations in A & B soils.
Can be used to depths of 30 feet and widths of up to 10 feet depending on soil conditions.
Rail Lengths 2, 4, 6, 8, 10
Cylinder Sizes29" - 43"
35" - 53"
41" - 62"
47" - 77"
53" - 89"75" - 117"
22
TRENCH PLATE® RENTAL CO www.TPRco.com
tr
Enc
h En
d Br
acE
trench end Brace Quik-Shor®
TPR FiRsT in seRvice
Double Cylinder Power Shore utilizes Two-2” diameter hydraulic cylinders.
Offering superior strength and versatility, Double Cylinder Power Shores can be used in a wide range of shoring projects.
The double cylinder power shore allows large horizontal and vertical spacing of shores against steel plates. Horizontal and vertical spacing can be as much as 10 feet, depending on conditions.
There is also a high clearance with these shores. The shores can be spaced up to 5 feet from the bottom of the trench.
Double cylinder power shores were developed to work in conjunction with 1" steel plate.
► Screw Jack
Ball and socket joint at each brace allowing rapid adjustment.
Shoe-face lugs grip planking firmly.
Adaptable trench widths by using varying lengths of standard pipe.
23d
ou
BlE
cy
lin
dEr
po
wEr
Sh
or
EdouBLe cyLinder Power shore Quik-Shor®
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
TPR FiRsT in seRvice24
TRENCH PLATE® RENTAL CO www.TPRco.com
po
wEr S
trut ● q
ua
dr
a Br
acE
Power strut ● Quadra Brace Quik-Shor®
3 inch Steel Cylinder Power Strut is a versatile and powerful shore. It can be used in conjunction with steel plate, sheeting, beams or timbers to create; 2-way Waler Systems Huge Vertical Shoring Systems Cross Braces for Beam and Plate Systems Utilizing a double acting steel cylinder for ease of use and strength. The strength and power of the 3 inch Steel Cylinder make it adaptable to challenging projects in unstable soils. with timber
Quadra Brace is a 4-way Waler system which can create an open excavation as small as 76" square / rectangular and up to 24 square / rectangular. The system uses 3" steel cylinders and steel extensions to create a variety of sizes and configurations. An extremely strong and versatile system for less stable soil conditions great for vaults, pump stations, tanks or any excavation needing a fully open area without cross bracing.
► Quadra Brace
► 3 inch Hydraulic Cylinders and Waler System
3 inch Hydraulic Cylinders and Waler System Designed for large clear span operations with minimal equipment needs. This system in conjunction with steel plates or overlap sheet pile is perfect for utility vault work and has the versatility to work around crossing utilities. Up to 30 feet of clear span for tunnel vaults
► 3 inch Steel Cylinder Power Strut
TPR FiRsT in seRvice
Fall Arrest The use of a personal fall arrest system is used as personal protective equipment for fall hazards. A personal fall arrest system consists of a full-body harness, lanyard, and anchor point OR a full-body harness, lanyard, lifeline, anchor point, and deceleration/grabbing device. All fall protection equipment shall meet or exceed appropriate American National Standards Institute (ANSI) standards. All employees whose work exposes them to falling in excess of 7 1/2 feet from the perimeter of a structure, unprotected sides and edges, leading edges, through shaft ways and openings shall use only commercially manufactured equipment specifically designed for fall protection and certified by a nationally recognized testing laboratory.
Common Active Systems
Components of an active personal fall protection system:● Anchorage point must support adequate loads.● Harness (or body belt for fall restraint or positioning) must be worn as per manufacturer instructions.● Connector (lanyard) must be adjusted so worker will not reach the ground below.● Free fall distance must never exceed 6 feet.
Types of active personal fall protection systems:1. Personal Fall Arrest System2. Personal Fall Restraint System3. Positioning Devices
Personal Fall Arrest System● Use harnesses, not body belts● Use shock absorbing lanyard with 2 locking snap hooks.● Anchorage point must support 5,000 lbs.● Inspect before use.● Inspect & document each system at least twice a year.● Plan for a prompt rescue.
Personal Fall Restraint System● The fall restraint equipment should be set and adjusted so there is no free fall over the edge.● A harness or body belt may be used● The anchorage point must support 4 times the intended load.
Positioning Devices● A harness or body belt may be used● The device must be set and adjusted so there is no more than 2 free fall.● The anchorage point must support 2 times the intended load or 3,000 lbs, whichever is greater.
25Fa
ll a
rr
ESt
FaLL arrest
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
TPR FiRsT in seRvice26
TRENCH PLATE® RENTAL CO www.TPRco.com
Fall Protection is a complicated issue and one of the most important faced by an employer or site supervisor. With over 100,000 reported incidents per year, falls from heights almost always result in serious injury.
9 ft. aluminum tripod is lightweight and portable, easily set-up by one worker
Adjusts from 7 ft. to 9 ft. height and will span a 6-1/2 ft. diameter hole
Complete with safety chain to prevent movement and safety shoes with rubber soles for flat surfaces and spiked edges for slippery surfaces.
Rated working load is 350 lbs. for work support and 310 lbs. for fall arrest, can withstand up to 5,000 lbs. of vertical pull.
Easy Operation; simply rotate the handle to raise or lower Gear ratio is 6:1 with an average lifting speed of 12.75 ft/min.
Free-Wheel Mode; an operator activated free wheel mode allows the drum to rotate and cable to pay-out freely
Built-In Fall Protection; The free-wheel mode has a built-in overspeed brake which provides secondary fall protection and added security
Level Wind; the drum level wind mechanism aids in spooling the cable onto the drum evenly and prevents slack line
Stainless steel and cast aluminum housing for corrosion resistance
50 ft. 3/16” galvanized steel wire rope for durability.
Built in retrieval winch for raising/lowering load during emergencies with built-in shock absorbing capabilities
Winch drive incorporates and overload device thus reducing the possibility of injury should the worker become entangled during retrieval
► 7-9 Tri-pod
► Sala Lift II Work Winch
► Sealed SRL with Retrieval Winch
We rent what you need to protect your workers. In addition, we sell a full line of Fall Protection Equipment from industry leading Manufacturers
► Harness Every DBI/SALA harness combines maximum comfort, freedom of movement and ease of use without sacrificing safety. All harnesses are designed to securely retain you in case of a fall and distribute the impact forces throughout your body. Whether you wear a harness 4 hours a day or 14 hours a day, it needs to feel good and fit right for optimum comfort, safety and productivity. DBI/SALA harnesses are designed to fit you - no matter what your size or shape!
tr
i-pod ● W
inc
h ● ha
rn
ess tri-Pod ● winch ● harness
TPR FiRsT in seRvice27
dav
it a
rm ●
Fall
ar
rES
t St
an
ch
ion
daVit arM ● stanchion
► Fall Arrest Stanchion Quik-Shor®
● The system is to be used with a personal fall arrest/restraint system complying with CCR title 8, CSO, article 24, §1670. ● Steel plate shall be minimum 6 feet wide and shall weigh a minimum of 4,000 lbs per person. (two people maximum).
● Fully engage coil screw such that bottom plate is tight and flush with steel plate surface. ● Do not use stanchion to lift trench plate heavier than 10,000 lbs.
Davit Arm retrieval systems are used to tie off workers who are suspended below a surface. Davits can be used for raising and lowering the worker to an area below the unit.
It can be mounted to a number of different support structures.
Davit Arm retrieval systems are an essential part of a confined space access or rescue plan. Davit Arms are also commonly used by Emergency Response Units for rescue in confined spaces.
► Davit Arm
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
TPR FiRsT in seRvice28
TRENCH PLATE® RENTAL CO www.TPRco.com
waLkways ● Bridges w
alk
wayS ● B
rid
gES ● g
ua
rd
ra
ilS
► Heavy Duty Trench Bridge
► Standard Duty Walkway
► Portable Bridge
Walkways are designed to meet state requirements associated with workers safely crossing trenches.
This Three Section Bridge easily bolts together to create a 38 foot long and 17½ foot outside dimension bridge.Bridge includes 3 foot 6 inch railings, and is designed for 102,000 lbs. gross carrying weight. Deck is diamond plate.
Heavy Duty Trench Bridge
Width Length Wt. Lbs.30" 8 26030" 12 38530" 16 50030" 20 600
Standard Duty Walkway
Width Length Wt. Lbs.28" 8 13328" 12 26028" 16 205
Quik-Shor®
Where employees or equipment are required or permitted to cross over excavations over 6-feet in depth and wider than 30 inches, walkways or bridges with standard guardrails shall be provided.
Guardrails fit on Trench Shields , Manhole Boxes and our Slide Rail System.
► Guardrails Quik-Shor®
All railings and components shall be capable of withstanding a force of at least 200 lbs. applied to the top rail within 2 in. of the top edge, in any outward or downward direction, at any point along the top edge.3. Mid-rails, screens, mesh, intermediate vertical members, solid panels, and equivalent members shall be capable of withstanding a force of at least 150 lbs. applied in anydownward or outward direction at any point.
TPR FiRsT in seRvice29
► Confined Space
► Permit-Required Confined Space
► Non-Permit Confined Space
► Hazardous Atmosphere
OSHA defines a confined space as any space in which the following three conditions exist concurrently:
1. The space is large enough and so configured that an employee can bodily enter and perform assigned work; and,2. The space has limited or restricted means for entry or exit; and,3. The space is not designed for continuous employee occupancy.
Examples of spaces which qualify as confined spaces under the OSHA definition include, but are not limited to: pipelines, storage tanks, vaults, vats, process vessels, catch basins, digesters, sewers, passageways, bins, boilers, pits, tank trucks, hoppers, tunnels, cargo holds, and excavations deeper than four feet.
A permit-required confined space is any confined space that has one or more of the following characteristics:
1. The space contains, or has the potential to contain, a hazardous atmosphere;2. The space contains a material which has the potential for engulfing an entrant3. The space has an internal configuration such that an entrant could be trapped or asphyxiated by inwardly converging walls or by a floor which slopes downward and tapers to a smaller cross- section; or, 4. The space contains any other recognized serious health or safety hazard.
A confined space that does not contain, or with respect to atmospheric hazards, have the potential to contain any hazard capable of causing death or serious physical harm.
An atmosphere is hazardous when it contains: 1. < 19.5% oxygen (O2 deficient) or > 23.5% oxygen (O2 enriched);2. A flammable gas, vapor, or mist at a concentration greater than 10% of its LEL (Lower Explosive Limit);3. A toxic material at a concentration greater than its PEL (Permissible Exposure Limit);4. A combustible dust at a concentration greater than its LEL, which may be approximated as a condition in which the dust obscures vision at a distance of 5 feet or less; or5. Any other atmospheric condition which is IDLH (Immediately Dangerous to Life or Health)
IDLH means any condition that poses an immediate or delayed threat to life or that would causeirreversible adverse health effects or that would interfere with an individuals ability to escape unaided from a permit space.
► Immediately Dangerous to Life or Health (IDLH)
Resource Information OnlyRefer to Specific Rules in your State
co
nFi
nEd
Spa
cE
dEF
init
ion
SconFined sPace deFinitions
OSHAs confined space regulations defines the following terms.
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
TPR FiRsT in seRvice30
TRENCH PLATE® RENTAL CO www.TPRco.com
► Electric Ventilator490 CFM 12 Volt DC, 15 Amps40 lbs. 25 Hose
Electric Ventilators are low maintenance, compact, and lightweight. Specifically designed to provide a completely portable source of fresh air in various underground, confined, and outdoor areas .
553 CFM 120 Volt AC, 3 Amps40 lbs. 25 Hose
●18" Inlet – Outlet● All Required OSHA Guards and Screens● Flashing Strobe Light when Operating● Fuel Requirements, 5 Gal. For 8 hrs.● 12,000 CFM Ventilator● Quiet and Economical ● Diesel Operated● Aluminum Impeller (reduced explosion risk)
► Diesel Ventilator Quik-Shor®
A Confined Space, in terms of OSHA and NIOSH safety requirements, refers to an area whose enclosed environment and limited access make it dangerous to workers. Confined spaces can be above or below ground level. Examples of confined spaces include pipes and sewers, crawl spaces, vents, vaults, tanks, pits, storage bins, vats and silos. Any area where access or egress is limited may be considered a confined space, especially if it is an area that can trap gases or where an injured or impaired worker may become trapped.
Ventilation is one of the most effective means of controlling hazardous atmospheres in restricted spaces.
Fans and blowers designed specifically for tight spaces can keep workers safe and promote good ventilation. Effective ventilation systems provide a method of maintaining a breathable atmosphere within the space by achieving a reduction in the level of atmospheric contaminates (gases, vapors, mists, fumes and dust) within the space.
vEn
tilator
S VentiLation eQuiPMent
TPR FiRsT in seRvice31
► Testing the Confined Space Atmosphere Hazardous atmospheres are the leading cause of death in confined space work. In addition, its estimated that inhalation causes 90% of all chemical injuries in general industry. Hazardous atmospheres often do not exhibit any warning properties and so may not present themselves in any way that an entrant can recognize though their physical senses. A hazardous atmosphere may be colorless, odorless and tasteless and, with some contaminants, the health effects of overexposure may not be felt right away. For these reasons it is essential that the confined space atmospheric conditions be thoroughly assessed before the operation commences and continuously throughout the entry.The entry supervisor is responsible for ensuring that a confined space atmosphere is tested before anyone enters the space and that the results of the testing are appropriately recorded on the entry permit. Entrants must be allowed to observe the pre-entry testing if they choose. The internal atmosphere must be tested with a calibrated, direct-reading instrument for the following conditions in the order given:
Oxygen content; Flammable gasses and vapors; and, Potential toxic air contaminants.
Oil and Gas (Drilling and Production Leak DetectionHot Work PermitsLPG Storage AreasOffshore and Onshore for Drilling - Production – Service Rigs Facility Turnarounds/ShutdownsConfined Space EntryVessel EntryPersonal Protection Equipment (PPE)Fire Brigade Municipalities(Dirty Water Treatment/Transmission &Clean Water Transmission)Confined Space EntryWater/Sewer Manhole EntrySewage Treatment FacilitiesLandfill Manhole Entry Utilities(Power Generation & Gas Distribution) Confined Space Entry Gas Leak DetectionOil, Gas and Coal Fired Power GenerationLandfill Gas GenerationHot Work PermitsTurnarounds/Shut downs Telecom Underground Work in Cable Splicing and Installation Controlled Environment Vault (CEV) WorkMan Hole EntryCable repair
Steel MillsConfined Space Entry General Worker Protection Pulp and PaperPersonal ProtectionVessel Entry and InspectionLeak DetectionWork Site SafetyConfined Space Entry ConstructionTrenching and ShoringUnderground WorkVentilation System Marine/ShippingVessel EntryShip Hold InspectionsHot Work Permits & Repair AirlinesTank Entry & CleaningWing Tank InspectionsFuel Storage TransportationTractor Trailer Tank CleaningRailcar Inspection and RepairTerminal Storage VesselsParking Garages
Tank Cleaning and Vessel Inspections-Confined Space EntryHot Work PermitsPersonal Protection Equipment (PPE)Planned Maintenance-Plant Turnarounds/Plant ShutdownsFire BrigadeLeak Detection Fire RescueHome CO Alarm ConfirmationHazmat ResponseConfined Space Entry Search and Rescue OperationsPost Fire Inspection Safety
Agriculture Grain Silo EntryFood Storage Elevators Regional Growers CommissionHog Barns Industry in GeneralMilitaryPharmaceuticalsMiningChemicals
Anywhere confined space entry is necessary
Refineries and Petrochemical Facilities
► Applications for Gas Detectors
Resource Information OnlyRefer to Specific Rules in your State
ha
zar
do
uS
atm
oSp
hEr
Ehazardous atMosPhere
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
TPR FiRsT in seRvice32
TRENCH PLATE® RENTAL CO www.TPRco.com
TPR has many types of Gas Detector Kits for rent or sale. Personal Single Gas and Multi Gas
Call us for a complete list of product and services.
GX-2009 Smallest Four Gas Confined Space Monitor Features:
● Simultaneous detection of 4 gases, LEL, O2, H2S & CO● Smallest / Lightest 4 gas monitor on the market | 2.7” H x 3” W x 1” D, 4.6 oz● Dual audible alarm ports (95 db @ 30 cm)● 3 visual alarm LEDs● Vibration alarm● IP-67 water-resistant/dust proof design● Calibration and bump test lock out or reminder controls● Large capacity data logging standard – 8 alarm trends – Log time range of 10 to 300 hrs – 100 calibration records● 20 hours of operation (NiMH batteries)● Large LCD display screen● Automatic backlighting at alarm● Impact resistant over-mold body, RFI shielded body● STEL and TWA readouts
Rental Gas Detector Kits Include sampling pump, sampling probe, rechargeable and replaceable battery packs. All units are manufactured by one of the world leaders in Gas Detection.
Gas Alert Micro 5 features audible, visual and vibrator alarms active in the event of a low, high TWA or STEL alarm condition.
po
rta
BlE g
aS d
EtEcto
r PortaBLe gas detector
TPR FiRsT in seRvice33
k-r
ail ●
wat
Er F
illE
d B
ar
riE
rk-raiL ● water FiLLed Barrier
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
► K-Rail
► Water Filled Barrier
Used as temporary barrier in work zones.Any quantity delivered to your job site.Meets all state regulations.
Water Filled Barrier is an alternative to concrete K-Rail. Six Foot lengths, weight 170 lbs empty, and approximately 1,700 lbs full.The customer is responsible for filling and draining.
● Cost effective
● Fast deployment
● Highly visible
● Work zone protection
● Traffic channeling & control
● Lane delineation
● Crowd control
● Soil erosion control
K-RailLengths Lbs.
10 4,00020 8,000
Concrete Barricades
TPR FiRsT in seRvice
► Message BoardThe Solar Message board is designed to provide advance warning information in text and graphical formats. This unit is desirable in temporary situation and long term changeable message sign applications where space restrictions do not allow large panel message boards.
► Solar Arrow PanelThe Solar Arrow Panel traffic controller is trailer mounted and has a self-contained solar power electronic charging system. It is designed to provide advance warning and directional information to assist in diverting and controlling traffic around construction or maintenance activities on or adjacent to the traveled roadway.
► Flashing Beacon LightSolar Recharged Flashing Yellow Beacon Light, can operate indefinitely when properly installed in most places.
● Halogen lamp for brighter light. ● Over-Charge protection during bright days.● Low-Charge protection for maximum battery life.● Horizontal & vertical adjustments.● Lockable battery box, 12" Lens. Height: 101” travel position
138” extended
34
TRENCH PLATE® RENTAL CO www.TPRco.com
BEac
on l
igh
t ● m
ESSagE B
oa
rd
Beacon Light ● Message Board
Our complete line of Traffic Control Equipment is available for rent or purchase. ● We provide Traffic Control Plans.● Complete set up and tear down of equipment on site. ● Custom Signs.
Barricades, Type I and IIIConesDrums Light TowersMessage BoardsSolar Arrow Panels Solar Message Boards Flashing Beacon LightsSignsCustom SignsSign Stands
Please call for a complete list of products and services.
Available at Traffic Control Speciality Locations TPR Traffic Solutions
TPR FiRsT in seRvice35
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
► Rock Screen Quik-Shor®
Other sizes available upon request
Rock Screens are designed for sifting rock and debris from soil on your job site.
Bedding Containers are designed with aggregate conservation in mind. Bedding material is confined thus eliminating loss of material, reducing traffic congestions and safety problems associated with front end loader dumping from the edge of the trench.
Capacity Size Wt. Lbs.7 CU Yards 48" x 60" x 160" 5,6009 CU Yards 48" x 64" x 181" 6,30012 CU Yards 48" x 75" x 200" 7,400
Screens Size2" Minus4" Minus6" Minus
► Bedding Container Quik-Shor®
ro
ck S
cr
EEn ●
BEd
din
g c
on
tain
Errock screen ● Bedding container
TPR FiRsT in seRvice
Inside application;
15 ton capacity42" -108"
30 ton capacity72" -144"
Remote control
Specifications
Remains stationary in the first pipe until the cables are extended and hooked to the end of the second pipe. A heavy-duty hydraulic cylinder draws the sections together minimizing grouting and pipe breakage.
Heavy Duty Pipe RollerHard Rubber Roller Bearing Rollers4000 pound capacity per unitFrom 48" to 1 ½" Pipe Capacity
● Less Pipe Breakage ● Safer, Tighter Joints ● Reduces Job Costs
► Pipe Puller
► Pipe Roller
This Pipe Roller features adjustable hard rubber coated Roller Bearing Rollers. The hard rubber is a big plus for field welding because the rubber absorbs small sand and grit for smoother rolling. Each roller unit is rated at 4000 pounds, (8000 for a two unit set-up). This Heavy Duty Pipe Roller can handle pipe up to 48" and as smalls as 1-1/2".
Quik-Shor®
36
TRENCH PLATE® RENTAL CO www.TPRco.com
pipE r
ollEr ● p
ipE pu
llEr PiPe roLLer ● PiPe PuLLer
TPR FiRsT in seRvice
Durable rugged construction Plug-It Products meet or exceed industry standards.
BLOCKING PLUG
LEAK LOCATOR WITH TEST-THRU PORTS
FLOW DIVERTER
● Test Plugs ● Blocking Plugs ● Flow Diverters ● Mechanical Plugs ● Manhole Testing Equipment
● Flow Block “Weenie” Plugs
● Wash BallsLEAK LOCATION REEL
Many sizes and other products are available for rent and sale.
We stock Plugs from
We custom design and build to fit your requirements.
3” to 48”
DUAL STAGE LONG
TEST PLUG
“WEENIE” PLUG
WASH BALL VACUUM TEST PLUG
37pi
pE p
lug
S ● l
Eak l
oc
ato
rS
PiPe PLugs ● Leak Locators
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
TPR FiRsT in seRvice
► Multi-Size Deflection Gauge
Deflection gauges are used to test pipes for obstructions; and detect any malformation of the pipe. This testing ensures that flexible pipe has been properly bedded and back-filled to give maximum performance.
► Mechanical Pipe Plug
Many sizes available for rent or sale
● Lightweight Aluminum
● Neoprene Sealing Ring
● 100% surface Contact
● All Parts Replaceable 4" thru 21"
● (D&T) Ready For Pressure Testing
38
TRENCH PLATE® RENTAL CO www.TPRco.com
dEFlEc
tion g
aug
E ● pipE p
lug
deFLection gauge ● MechanicaL PiPe PLug
TPR FiRsT in seRvice39
TOPICS DISCUSSED OSHA General Requirements Requirements for protective systems Soil classification Selection of protective systems How to read tabulated data sheets Checklists / Resources
INCLUDED Comprehensive manual Certificate of course completion
Competent Person Training“Competent person” means one who is capable of identifying existing and predictable hazards in the surroundings or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them.
This program has been designed to provide your labor force with the classroom training which along with their field experience may enable them to become a “Competent Person” as defined by OSHA.
Confined Space AwarenessThis class has been designed to explain the hazards of confined space work and to assist employers in establishing and maintaining an effective confined space program. By implementing such a program, both employers and employees will be able to:
Recognize, evaluate, and control confined space hazards. Save lives and protect employees from job-related injuries and illnesses. Promote safe and effective work practices. Comply with the law.
Understand the scope & application of OSHA's various confined space entry standards Identify "Confined Spaces", then determine if they are "Permit Required" Understand OSHA requirements for developing and maintaining a "Permit-required confined space entry program" permit Know responsibilities of entrants, attendants, entry supervisors, contractors Identify when you may utilize OSHA's "Alternate Entry" and "Reclassification" procedures Understand the requirements for "Rescue & Emergency Services" Have a basic knowledge of the general use and limitations of related equipment
COURSE OBJECTIVES
OSHA data shows on average 35 workers die in trenching or excavation cave-ins yearly. 64% of fatalities in trenches occurred at depths of less than 10 feet.
tra
inin
gcoMPetent Person ● conFined sPace
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
TPR FiRsT in seRvice40
TRENCH PLATE® RENTAL CO www.TPRco.com
Slo
ping & B
Enc
hin
g sLoPing & Benching
Sloping & Benching Hydraulic ShoringNote: Always install shoring from the top down
& remove from the bottom up.
General Trenching and Excavation Rules
● Keep heavy equipment away from trench edges.● Identify other sources that might affect trench stability.● Keep excavated soil (spoils) and other materials at least 2 feet from trench edges.● Know where underground utilities are located before digging.● Test for atmospheric hazards such as low oxygen, hazardous fumes and toxic gases when > 4 feet deep.● Inspect trenches at the start of each shift.● Inspect trenches following a rainstorm or other water intrusion.● Do not work under suspended or raised loads and materials.● Inspect trenches after any occurrence that could have changed conditions in the trench.● Ensure that personnel wear high visibility or other suitable clothing when exposed to vehicular traffic.
41Ex
cav
atio
n S
aFE
tyexcaVation saFety
TRENCH PLATE® RENTAL CO Toll free: 800-821-4478
EXCAVATION SAFETY “COMPETENT PERSON” : One who is capable of identifying existing or predictable hazards in the surroundings or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them. When applied to trenching or excavation operations, the “Competent Person” must have specific training in, and be knowledgeable about, soil analysis, the use of protective systems, and the requirements of this standard. In addition, the “Competent Person” must have the authority to take immediate action if a hazard exists. INSPECTIONS: Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.
GENERAL REQUIREMENTS Protecting Surface Encumbrances that may create a hazard to employees. Locate Underground Installations prior to opening an excavation must meet all State / Federal guidelines. Provide appropriate Access and Egress. ≥4feet. Reduce Exposure to Vehicular Traffic. with issue of warning vests. Employee Exposure to Falling Loads shall be eliminated. Provide a Warning System for Mobile Equipment operating adjacent to or near an excavation. Testing the air in excavations to identify potentially Hazardous Atmospheres ≥4ft. Protection from Hazards Associated with Water Accumulation. Ensuring the Stability of Adjacent Structures. Adequate Protection of Employees from Loose Rock or Soil that could pose a hazard. Daily Inspections by a competent person (see above definition). Appropriate Fall Protection near excavations. ≥6ft.
REQUIREMENTS FOR PROTECTIVE SYSTEMS Each employee in an excavation shall be protected from cave-ins by an adequate protective system except when excavations are less than 5 feet in depth and examination of the ground by a competent person provides no indication of a potential cave-in.
TPR FiRsT in seRvice
TPR FiRsT in seRvice42
TRENCH PLATE® RENTAL CO www.TPRco.com
mEtr
ic co
nv
ErSio
n Metric conVersion
FIRST IN SERVICE
Trench Plate® Rental CoCorporate Office
13217 Laureldale Ave Downey, CA 90242
Ph: 888-833-3777 [email protected]
tprco.comSouthern Region California Los Angeles 800-821-4478 North Los Angeles 877-246-4087 Ventura / Santa Barbara 855-834-9058 Orange County 800-772-8004 Inland Empire 877-246-4085 San Diego 800-350-7528
Rockies Region Colorado Denver 303-287-2264 Colorado Springs 719-633-4556 Berthoud 970-532-4066 Grand Junction 970-523-8520 New Mexico Albuquerque 505-881-4830 Utah Provo 801-356-0100 Salt Lake City 801-265-1366
Eastern Region Alabama Birmingham 205-956-1668 Florida Jacksonville 904-786-4100 Miami 844-724-4446 Orlando 888-777-8307 Tampa 844-724-4445 Georgia Atlanta / West 404-505-0510 Atlanta / North 770-932-2165 Atlanta 866-260-8609 Illinois Chicago 800-220-8707 Pennsylvania Pittsburgh 412-331-8118
TPR Traffic Solutions California Los Angeles / Orange Co. 866-537-1260 Inland Empire 855-326-5953 San Diego 833-758-7660 San Leandro 855-351-1114 Nevada Las Vegas 877-809-6493
Traffic Control Speciality Locations
Northern Region California San Francisco N. Bay Area 800-321-5550 San Francisco S. Bay Area 877-246-4086 Sacramento 800-548-0688 Fresno - Central Valley 844-803-8408 Nevada Reno 877-809-6492 Las Vegas 877-809-6493
Texas Region Texas Dallas / Ft. Worth 817-502-1444 Houston 866-247-9449 San Antonio 866-501-8955