40
ISOBUS PFP13080

ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

  • Upload
    lydang

  • View
    276

  • Download
    3

Embed Size (px)

Citation preview

Page 1: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

ISOBUS

PFP13080

Page 2: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

Copyright © 2013 Deere & Company. All Rights Reserved. THIS MATERIAL IS THE PROPERTY OF DEERE & COMPANY. ALL USE AND/OR REPRODUCTION NOT SPECIFICALLY AUTHORIZED BY DEERE & COMPANY IS PROHIBITED. All information, illustrations and specifications in this manual are based on the latest information available at the time of publication. The right is reserved to make changes at any time without notice.

About This DocumentThis user guide will help you learn about ISOBUS. It will explain:

• Hardware, such as connectors

• Settings necessary on a John Deere display to support ISOBUS implements

• Theory of operation behind ISOBUS system

It is a supplement to the 2630 or 1800 Display’s operator’s manual and ISOBUS-compatible machine or implement operator’s manual.

Read the Operator’s Manual for the following information:

• How to operate your ISOBUS implement safely

• How to operate your tractor safely

• How to operate your display safely

Page 3: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

Section Contents

ISOBUS GENERAL INFORMATION .......................................3

What is ISOBUS? ................................................................................ 3Connectors ........................................................................................... 5

CANBUS GENERAL INFORMATION .....................................7

What is CANBUS?................................................................................ 7Communication on the CANBUS.......................................................... 8Vehicle BUS Versus Implement BUS ................................................... 9

VIRTUAL TERMINAL AND VIRTUAL IMPLEMENT.......10

What is Virtual Terminal? ................................................................... 10What is Virtual implement?................................................................. 11

AUXILIARY CONTROL ...........................................................13

Theory of Operation............................................................................ 13Auxiliary Control Old Versus Auxiliary Control New ........................... 14

AUXILIARY CONTROL ON GREENSTAR DISPLAYS .....15

Description of the Symbols................................................................. 15Assign Functions to Joystick Buttons ................................................. 16Manual Assignment ............................................................................ 17

TASK CONTROLLER ...............................................................18

To verify if TC is on the BUS: ............................................................. 18Verify if the Implement Supports TC................................................... 20

MULTIPLE DISPLAY................................................................21

Move Virtual Implement Between Displays ........................................ 21Enable VT and TC on 1800 Display and GS3 CommandCenter........ 23Change Priority (Function Instance) of VT and TC on 1800 Display .. 23Enable VT and TC on 2630 Display ................................................... 24Change Priority (Function Instance) of VT and TC on 2630 Display .. 25

ISOBUS DIAGNOSTICS............................................................27

ISOBUS Diagnostics - Implement VI Does not Appear on Display .... 27ISOBUS Diagnostics: John Deere Section Control Icon Does Not Ap-pear .................................................................................................... 31

GS3 2630 DisplayGS3 2630 Display1

Page 4: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

PRESCRIPTION DOES NOT WORK......................................33

GS3 2630 DisplayGS3 2630 Display2

Page 5: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

ISOBUS General Information

Instead of using ten different control boxes in the cab, ISOBUS allows the operator to use one display for an entire fleet of implements.

What is ISOBUS?

ISO: International Standardization Organization

BUS: Binary Unit System

BUS is a generic term to describe the physical connection between electronic components, such as:

• ISOBUS

• CANBUS

• CCDBUS

ISOBUS allows customers to use one display that works with:

• Deere tractors and Deere implements

John Deere Tractor

with GreenStar 2630 Display(ISOBUS Compatible)

Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements

GS3 2630 DisplayGS3 2630 Display3

Page 6: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

• Deere tractors and non-Deere implements

• Deere implements behind non-Deere tractors

• AMS applications interfacing with Deere and non-Deere products

• Compatibility check and diagnostic tools for machine combina-tions of John Deere and non-Deere machines.

To meet ISO11783 standard, ISOBUS is the first worldwide standard for dated communication between:

• Tractors

• Displays

• Implements

• Farm management software

This user guide identifies components that support ISOBUS.

GS3 2630 DisplayGS3 2630 Display4

Page 7: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

Connectors

Detailed specification of connectors include:

○ 9 pole in cab ISO connector: a tractor that is ISOBUS com-patible has this connector somewhere in the cab.

○ Implement Bus Breakaway Connector (IBBC): a tractor that is ISOBUS compatible has this connector somewhere in the rear.

○ Implement Bus Breakaway Plug-in (IBBP), or ISO Plug-in: an implement that is ISOBUS compatible has this connector, to be able to connect to the tractor.

○ Diagnostic Connector (Service Advisor Connector)

○ Service Advisor Connector for John Deere machines

GS3 2630 DisplayGS3 2630 Display5

Page 8: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

○ Standard connector for BUS extension is a four-pole Deutsch

connector

GS3 2630 DisplayGS3 2630 Display6

Page 9: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

CANBUS General Information

What is CANBUS?

CAN: Controller Area Network

CANBUS is a harness that runs from the front of the machine to the rear. All controllers on the machine can communicate with each other using this CANBUS system. Controllers may include the engine controller, hydraulic controller, and transmission controller.

CANBUS is four wire system, including CAN high (yellow), CAN low (green), CAN power (red), and CAN ground (black). Also, CANBUS contains an electric power supply, also referred to as the “active terminator”, with battery power and battery ground to keep CANBUS level at the desired Voltage. The picture above shows the active terminator as filter and voltage regulator.

The passive terminator can be seen in the picture below.

GS3 2630 DisplayGS3 2630 Display7

Page 10: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

CAN high and CAN low wires transmit data, or messages, on BUS using binary code (0 [power on]/1 [power off]). As shown in the picture above, voltage of both CAN high and CAN low is 2.5 V if there are no messages on the BUS.

If a message is sent, CAN high increases 1 V, and CAN low decreases by 1 V during the time the bit is sent.

Communication on the CANBUS

The picture below shows how the GS3 2630 and sprayer communicate with each other on a step-by-step basis.

Messages transmitted on the CANBUS enable the communication between tractor and implement. Messages include loading the graphic user interface section control commands and documentation values, such as application rate.

I am a Sprayer. What can you do?

I am a VT.

I speak English.

I have a color 480 x 480 data maskarea and 64 colors...

Here is my user interface.

Operator input,such as opening the section

Implement action, such as opening the section

JD Sprayer

John Deere Sprayer

2630 Display

GS3 2630 DisplayGS3 2630 Display8

Page 11: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

Vehicle BUS Versus Implement BUS

Vehicle CANBUS on tractor: Connects engine in front of the tractor with transmission and hydraulics in rear of the tractor and enables communication between them.

Implement CANBUS on tractor: Connects GPS receiver, display (VT and TC), and ISOBUS Plug-in (IBBC) in rear of the tractor.

ISOBUS extends the tractor implement CANBUS to the implement. This extension results in the implement and the tractor communicating over the same CANBUS system.

VT

GPS TC

Implement BUSTECU

Tractor BUS:1. Transmission2. Hydraulics3. Engine

ISOBUS Plug-in(Active Terminator)

PassiveTerminator

GPS

VT

TCPassiveTerminator ISOBUS Plug-in

Sensor

ImplementController

Implement BUSTECU

Active Terminator

GS3 2630 DisplayGS3 2630 Display9

Page 12: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

Virtual Terminal and Virtual Implement

What is Virtual Terminal?

• Virtual Terminal (VT) is a part of the software of John Deere GreenStar 2 and GreenStar 3 displays.

• VT is a standardized display for all controller and implements on the BUS. John Deere Virtual Terminal offers a size of 640 x 480 pixels.

• The implement loads its graphic user interface, also referred to as Virtual Implement (VI), into the VT as indicated in the picture below, in this example the VI of a John Deere Sprayer is displayed by a 2630.

• When VI gets loaded into the 2630 display, a status bar will show how far the upload has progressed.

• Once the VI has been loaded into the Display it will be saved in the Displays internal memory. When the display detects the same implement again (for example after shutdown or disconnection) the display will load the VI out of its internal memory and display it.

• VT is comparable to a monitor on personal computers, which dis-plays information processed by a control unit on the implement. This means that all pages shown in the VT (implement icon on main menu) are neither controlled nor handled by the 2630 Soft-ware.

Virtual ImplementFor Example: JD Sprayer 962i Virtual Display

For Example: GreenStar 3 2630

GS3 2630 DisplayGS3 2630 Display10

Page 13: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

What is Virtual implement?

VT displays the Virtual Implement (VI) of the implements connected to the tractor CANBUS. VI is the graphic user interface of the implement. While the real implement (iron part) is located in the rear of the tractor, its user interface, the virtual part of the implement or VI, is located on the display.

Since the VT is just displaying the VI, frozen VI pages are most likely to be caused by an overloaded implement control unit.

VI retrieves input from operator and controls the implement. Pressing a button causes the implement controller to perform a specific movement of the implement, such as opening a section.

John Deere 2630 Display can display multiple VI at the same time. For example:

To verify if VI and VT compatible:

1. Plug implement into ISO plug-in

2. Main Menu ....................................................................3. Check status bar of implement (GS3 2630 only)

4. Check for ISOBUS conformance stickers on the implement

OriginalGreenStar

Monitor

PerformanceMonitor

MessageCenter

StarFire3000

Machine3338SN:

Display

LayoutManager

Access Manager

Video

Calculator

Standby

Air CartPlanter

GreenStar

John Deere

GS3 2630 DisplayGS3 2630 Display11

Page 14: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

GS3 2630 DisplayGS3 2630 Display12

Page 15: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

Auxiliary Control

Theory of Operation

Operator connects the ISOBUS-compatible joystick, implement, and 2630 display to the tractor CANBUS.

Instead of pressing the implement softkey on the display to start the

pickup of the implement , the operator can press a

button on the joystick to control the implement function. The pickup will then start.

a. Combining a joystick button with a specific implement move-ment or function is called assignment.

Display, Joystick, and Implement Working Together

GS3 2630 DisplayGS3 2630 Display13

Page 16: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

b. Auxiliary control assignments are stored on the implement for

each implement or joystick combination.

c. Assignments are loaded from the implement to the display at each startup.

d. After loading assignments, joystick can be used.

e. John Deere 2630 Display provides a user interface for mak-ing assignments.

Auxiliary Control Old Versus Auxiliary Control New

There are two standards of auxiliary controls that are not compatible:

• Auxiliary Control Old (AUX-O)

• Auxiliary Control New (AUX-N)

The ISOBUS implement, the VT, and AUX Control joystick need to use the same standard. For example:

Assignment Operate or use

GS3 2630 DisplayGS3 2630 Display14

Page 17: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

Auxiliary Control on GreenStar Displays

Description of the Symbols

Assignment completed correctly. ............................................

Operator can use function when ISO AUX is enabled.

Assignment has conflicts. ......................................................

Function is disabled, while ISO Aux is enabled. Operator will need to identify and solve conflicts.

Assignment completed correctly, but auxiliary control is

disabled. ................................................................................

Operator needs to enable ISO Auxiliary controls.

Assignment has conflicts and Auxiliary control is disabled. ....

A conflict appears when the operator tries to assign a function (example: stop machine), which requires to be assigned independent from other functions, in combination with an additional function (example: open the gate).

Preferred assignment lock. ............................................................

Assignment cannot be set manually. Function will be assigned to this button automatically. For example, a baler requires a special function (example: open the gate) to be assigned with the lower left button of the joystick.

GS3 2630 DisplayGS3 2630 Display15

Page 18: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

Assignment lock bit. .....................................................................

Assignments marked with lock bit symbol cannot be combined with another function on the input device to avoid machine damage or personal injury. For example, a baler requires a specific function (example: open the gate) to be assigned on one button separately and independently from other functions.

Conflict markers. ...........................................................................

Conflict counter groups related conflicts together. All the conflicts with the same number are related to each other. A conflict appears when the operator tries to assign a function (example: stop machine), which requires to be assigned independent from other functions in combination with an additional function (example: open the gate).

Assign Functions to Joystick Buttons

In View field:

1. Main Menu ...................................................................

2. Display ............................................................

3. Reconfigurable Controls .........................................4. Select Mapped to view active assignments.

View

To make assignments automatically:

1. Select Learn Mode.

Status

Display

Mapped

Learn Mode

GS3 2630 DisplayGS3 2630 Display16

Page 19: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

NOTE: Implement will not take action while display is in Learn Mode.

2. Several possible assignments will be shown. For example:

3. Press button on joystick to assign the function that will appear on display.

NOTE: Please refer to the operator’s manual of the joystick to find out how to operate the joystick correctly.

4. Cursor jumps to the next possible assignment automatically. Repeat steps three and four for each function to be assigned.

NOTE: Press down arrow to skip a function. ..................................

Manual Assignment

1. Use up and down arrows to navigate to desired function.

2. Select Un-mapped. ..................................................3. Select desired joystick out of the drop-down list.

4. Select Un-mapped. ..................................................5. Select desired button from drop-down list.

GS3 2630 DisplayGS3 2630 Display17

Page 20: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

Task Controller

Task Controller (TC) is a part of the software of the John Deere 2630 Display. As described by its name, TC controls one or several tasks. Those tasks are:

• John Deere Section Control or Swath Control .................

• Map-based prescriptions ............................................

• Documentation ....................................

TC client, or slave, is the dependent TC to the master controller on the 2630 display. TC client communicates with the operator using the VI and the equipment setup pages of the GreenStar display.

When GreenStar 2630 is started, TC tells other controllers on the BUS of its presence. Unlike the VT, TaskController can only communicate with ONE implement connected to the 2630. In the list of all controllers, TC shows up as TSK 0XF7.

To verify if TC is on the BUS:

1. Main Menu ...................................................................

Task Controller ClientFor Example: Spreader

Task Controller (Master)For Example: 2630 Display

GS3 2630 DisplayGS3 2630 Display18

Page 21: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

2. Message Center ..................................................

3. Control Unit ...................................................................

In the picture below, TC communicates with the BUS. It uses the acronym TSK and the address 0xF7.

TC client will display most commonly underneath the Original GreenStar Monitor (OGM), which has the address 0x80. TC client commonly uses an acronym starting with a question mark and an address between 0x81 and 0x87, as indicated in the chart below.

If master TC on GS display is inactive, TC client on implement is not able to communicate with it.

Preconditions for TC to communicate properly:

• Both TC on 2630 display and TC client on implement need to be active, TC client on implement receives messages so that they can communicate with each other. For example, TC client on the implement receives section control messages (section ON/OFF) from the Task Controller on the display.

• If TC client on the implement is inactive, TC (master) on the dis-play is not able to communicate with it.

• If the TC master on the display is inactive, the TC client on the implement is not able to communicate with it.

GS3 2630 DisplayGS3 2630 Display19

Page 22: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

NOTE: This means that TC on the implement and on the GreenStar display has to be enabled for section control to work.

Verify if the Implement Supports TC

1. Main Menu ....................................................................

2. GreenStar .......................................................

3. GreenStar Main .............................................................

4. Equipment ...................................................................

5. Machine tab ...........................................................

6. Ensure recording source is Auto .................

7. Implement tab ........................................................

8. Ensure Implement Type is grayed out .......

Machine

Implement

GS3 2630 DisplayGS3 2630 Display20

Page 23: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

Multiple Display

If two displays, such as John Deere 2630 Display and GreenStar 3 Command Center, are connected to the same BUS, the VI runs completely independent from Section Control and Prescriptions.

As indicated in the picture above, the VI of the spreader is shown on the CommandCenter, while section control, guidance, and documentation run on the GS3 2630 Display.

In order to run a tractor with a multiple display configuration, both displays need to be configured correctly. For example, TC and VT can be switched off if it is not needed to display an implement GS3 CommandCenter. In addition, it is possible to assign priorities, or function instances, to TC and VT.

Move Virtual Implement Between Displays

NOTE: This functionality is only available if two displays are physically connected to the CANBUS and both displays have VT functionality enabled. For more information on how to enable VT, see Enable VT and TC section of this guide.

On StarFire 3000, John Deere Implement Detection Controller, and iSteer, move VI as indicated in the steps below between displays.

1. Main Menu .....................................................................

2. Implement icon ....................................................

VTFor Example: Command Center and Spreader VI

TCFor Example: 2630 Display

TC ClientFor Example: Spreader

GS3 2630 DisplayGS3 2630 Display21

Page 24: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

3. Next VT ..................................................................................

On John Deere SeedStar planters, follow the steps below to move VI:

1. Main Menu ..........................................................................

2. Planter ..............................................................

3. Planter Settings ............................................................

4. Display tab .............................................................

5. Next VT ..................................................................................

On John Deere pull type sprayers, follow the steps below to move VI:

1. Main Menu ..........................................................................

2. JD Sprayer ....................................................

3. Sprayer Main Menu ......................................................

4. Diagnostics .................................................................

5. Change VT ..............................................................

Display

Change VT

GS3 2630 DisplayGS3 2630 Display22

Page 25: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

Enable VT and TC on 1800 Display and GS3 Command-Center

VT needs to be enabled so that the display can show the VI of the implement.

TC needs to be enabled so that the display can perform section control, documentation, or prescriptions.

NOTE: TC settings are not available on GS3 CommandCenter.

1. Main Menu ..........................................................................

2. Display ............................................................

3. Settings ......................................................................

4. Multiple Display Settings ..........................................

5. Change Settings ....................................................

6. Check implement bus to enable VT...........................

7. Next Page ....................................................................

NOTE: Steps 7 and 8 are not available on a GS3 CommandCenter.

8. Check Task Controller to enable TC .........................

9. Save Settings and Restart Display........................

Change Priority (Function Instance) of VT and TC on 1800 Display

In case of a multiple display configuration, there should never be two VT or two TC connected to the same CANBUS with the same priority

Display

Change Settings

Save Settings andRestart Display

GS3 2630 DisplayGS3 2630 Display23

Page 26: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

(=function instance). For example, primary display should have priority 1, and secondary display should have priority 2.

1. Main Menu ..........................................................................

2. Display ............................................................

3. Settings ......................................................................

4. Multiple Display Settings .........................................

5. Change Settings ....................................................6. Change function instance of implement BUS to change

priority of VT ...........................................

7. Next Page ....................................................................

NOTE: Steps 7 and 8 are not available on GS3 CommandCenter.

8. Change function instance to change priority of Task

Controller ..............................................

9. Save Settings and Restart Display .......................

Enable VT and TC on 2630 Display

VT needs to be enabled so that the display can show the VI of the implement.

TC needs to be enabled so that the display can perform section control, documentation, or prescriptions.

Display

Change Settings

Save Settings andRestart Display

GS3 2630 DisplayGS3 2630 Display24

Page 27: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

To enable VT and TC:

1. Main Menu ....................................................................

2. Display ............................................................

3. Diagnostics .................................................................

4. Multiple Displays tab .............................................

5. Change Settings ....................................................

6. Check implement BUS to enable VT .........................

7. Next Page .....................................................................

8. Check Task Controller to enable TC .........................

9. Save Settings and Restart Display .......................

Change Priority (Function Instance) of VT and TC on 2630 Display

In case of a multiple display configuration, there should never be two VT or two TC connected to the same CANBUS with the same priority (=function instance). For example, primary display should have priority 1, and secondary display should have priority 2.

To change priority on a 2630 display:

1. Main Menu ....................................................................

2. Display ............................................................

Display

Multiple Displays

Change Settings

Save Settings andRestart Display

Display

GS3 2630 DisplayGS3 2630 Display25

Page 28: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

3. Diagnostics .................................................................

4. Multiple Displays tab .............................................

5. Change Settings ....................................................

6. Check implement BUS to enable VT ...

7. Next Page .....................................................................8. Change function instance of Task Controller to change

priority ..................................................

9. Save Settings and Restart Display .......................

The priorities should now be correctly assigned according to the Display Priority.

Multiple Displays

Change Settings

Save Settings andRestart Display

GS3 2630 DisplayGS3 2630 Display26

Page 29: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

ISOBUS Diagnostics

Before starting the diagnostic procedure, ensure the task controller of the specific software version is capable of performing the desired operation. Check the tables at end of this document to find out which display and which software Version is capable of which operation.

ISOBUS Diagnostics - Implement VI Does not Appear on Display

1. Check if implement controller is connected to the CANBUS.

a. Menu ..................................................................

b. Message Center ...............................................

c. Control Unit ...............................................................

d. Select Implement CAN ....................

e. Use arrows to navigate through the list of connected controllers to find the implement controller.

NOTE: Most ISOBUS controllers show up with the address 81 through 87 and start with a question mark. So they can be found right underneath OGM. See task Controller section of this guide for more information.

f. If controller does not appear on the BUS, there is a problem with the harness itself. This could be a broken wire, corroded pin, or loose connector.

Implement CAN

GS3 2630 DisplayGS3 2630 Display27

Page 30: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

2. Verify VT settings on display:

A. Ensure that Function Instance (of primary display) for VT (implement BUS) is set to “1.” As some implements only load the graphic user interface (VI) to VT with function

instance “1” ..................................................................

B. Ensure that VT is enabled (implement BUS is checked).

C. If a multiple display configuration is used, ensure function instance (priority) of secondary display is set to a value of

“2” or higher. ................................................................

NOTE: Refer to enable VT and TC /Change Priority of VT and TC Section of this user guide for a step-by-step description of how to perform the steps above.

3. Delete implement VI from the display and reboot. This will force the implement to load its user interface completely new into the GreenStar display. This will solve the issue, if corrupt files have been loaded to the display before. See Virtual Terminal and Virtual implement section of this guide for more information

NOTE: This function is not available on GreenStar 2 2600 displays and GreenStar 3 CommandCenter displays.

Delete VI on 2630 display:

a. Menu .......................................................................

b. Message Center .............................................

c. Select Cleanup ........................................................

d. Check Controllers ...........................................

e. Select Begin Cleanup ....................................

Delete implement VI on 1800 display:

Begin Cleanup

GS3 2630 DisplayGS3 2630 Display28

Page 31: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

a. Menu...................................................................

b. Message Center .............................................

c. Select Camera .........................................................

d. Select Remove Controllers .....................

4. When trying to connect an ISOBUS implement to a GS3 CommandCenter, set the vehicle system to “0.”

Verify Settings on CommandCenter

1. Main menu ....................................................................

2. Display ............................................................

3. Settings ......................................................................

4. Multiple Display Settings ........................................

5. Change Settings ....................................................6. Change vehicle system for implement BUS from 1 to 0

Vehicle system “1” means that the display is set to “Vehicle” or “Tractor” display. Vehicle system “0” means the display is setup as a general display. Some implements do not load their VI into a tractor display.

If using multiple display configuration, disconnect second display.

Remove Controllers

Display

Change Settings

GS3 2630 DisplayGS3 2630 Display29

Page 32: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

Restore factory settings on command center.

a. Menu ..................................................................

b. Message Center .............................................

c. Settings .....................................................................

d. Restore Factory Default Settings ..........

e. Wait for about two minutes. Display should show a screen that “John Deere Display has been removed” and prompt to restart.

f. Reboot system by switching ignition OFF and ON.

NOTE: If implement VI still does not appear, perform a cold boot and/or follow steps 1 through 9 in the “Change priority of VT and TC" section, and repeat steps a through f of this section.

To perform a cold boot correctly:

• Stop engine, switch ignition off, unplug display and implement from tractor power supply.

Or

• Stop engine, switch ignition off. Turn battery switch off, turn igni-tion key on, wait five seconds, turn ignition key off, switch battery switch on, and then start tractor.

Or

• Stop engine, switch ignition off. Unplug battery, turn ignition key on, wait five seconds, turn ignition off, replug battery, and then start tractor.

NOTE: If implement VI still does not appear, contact John Deere Dealer.

Restore Factory

Default Settings

GS3 2630 DisplayGS3 2630 Display30

Page 33: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

ISOBUS Diagnostics: John Deere Section Con-trol Icon Does Not Appear

• Ensure function instance for TC on primary display is enabled

and set to “1.” ....................................................................

• Ensure TC is enabled ...........................................................

NOTE: Refer to enable VT and TC section of this user for a step-by-step description of how to perform the above named steps.

• Ensure implement is capable of section control or variable rates. Also, ensure TC on implement is enabled.

NOTE: Contact the implement manufacturer to find out if the implement is section control capable.

To verify if TC is working on a John Deere Sprayer:

1. Menu .............................................................................

2. JD Sprayer ...........................................................

3. Job settings ..................................................................

4. Task Controller ..............

NOTE: The same procedure can be done on non-Deere implements, such as Kverneland implements. Contact the manufacturer of the implement or read the operator’s manual to find out how to enable TC on the machine.

• In case two implements are connected, ensure display commu-nicates the correct implement.

NOTE: TC can only communicate with one implement. It always communicates to the implement, which is grayed out on the equipment setup page.

Disabled Control & Doc

GS3 2630 DisplayGS3 2630 Display31

Page 34: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

• An informational message will inform the operator as soon as

task Controller detects two implements trying to connect to the Display.

• Select the correct implement out of the drop-down list.

NOTE: In case the incorrect implement has been selected before, disconnect and reconnect implements. Display will prompt, with which implement TaskController should communicate.

Too many implements connected

The task controller has detected more than one supported ISO implement. Please select the desired implement below.

GS3 2630 DisplayGS3 2630 Display32

Page 35: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

Prescription Does Not Work

Verify prescription has the prescription rate unit supported by the implement. For example, a prescription setup in mass/area cannot be applied by an implement requiring seed/area.

NOTE: Refer to 2630 Documentation User Guide for more information on prescriptions and their setup.

Verify that implement is set up to work with prescriptions. On some implements such as a John Deere Sprayer this feature needs to be enabled.

Follow the steps below to enable prescriptions on a John Deere Sprayer.

1. Main Menu ....................................................................

2. Sprayer ...............................................................

3. Job Settings .................................................................4. Change external target rate source

NOTE: The same procedure might have to be done on Non-Deere implements, such as Kverneland implements. Contact the manufacturer or read the operator’s manual to find out how to enable Prescriptions on the specific implements.

None Appl. Map

GS3 2630 DisplayGS3 2630 Display33

Page 36: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

GreenStar 2 1800 Display Task Controller Capabilities2.6. & older 2.8 & newer

Capable to Communicate with (for example for documentation purposes)spreader yes yessprayer yes yesseeder/planter yes yesbaler no yesliquid fertilizer tool no yestillage no yestransport no yeshay and forage no yesSection Control capablespreader John Deere only John Deere onlysprayer John Deere only John Deere onlyseeder/planter John Deere only John Deere onlyliquid fertilizer tool no nohay and forage no noCapable to read implement setup dataimplement type yes yesimplement model no noimplement name no noconnection type no noOffsets no noTurn on/off times no noGPS receiver offsets no nophysical width no noimplement width yes yesturn radius no notrack spacing no noimplement totals yes yeslateral offsets of implement sections no yes

GS3 2630 DisplayGS3 2630 Display34

Page 37: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

* Spreader pro universal activation required. The activation might not be available in all countries.

** Sprayer pro universal activation required. The activation might not be available in all countries

*** Seeder pro universal activation required. The activation might not be available in all countries.

GreenStar 2 2600 Display Task Controller Capabilities2.3.1385 & older

2.4.1156 2.5.1111 & newer

Capable to communicate (for example for documentation purposes)spreader yes yes yessprayer yes yes yesseeder/planter yes yes yesbaler no no noliquid fertilizer tool no no notillage no no notransport no no nohay and forage no no noSection Control capable

spreader John Deere only John Deere only yes*sprayer John Deere only John Deere only yes**seeder/planter John Deere only John Deere only yes***liquid fertilizer tool no no nohay and forage no no noCapable to read implement setup dataimplement type yes yes yesimplement model no no noimplement name no no noconnection type no no noOffsets no no noTurn on/off times no no noGPS receiver offsets no no nophysical width no no noimplement width yes yes yesturn radius no no notrack spacing no no noimplement totals yes no nolateral offsets of implement sections no no no

GS3 2630 DisplayGS3 2630 Display35

Page 38: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

GreenStar 3 2630 Display Task Controller Capabilities3.1.xxxx & older

3.4.1338 3.10.1320 & newer

Capable to communicate with (for example for documentation purposes)spreader yes yes yessprayer yes yes yesseeder/planter yes yes yesbaler no yes yesliquid fertilizer tool no yes yestillage no no yestransport no yes yeshay and forage no no noSection Control capablespreader yes yes yessprayer yes yes yesseeder/planter yes yes yesliquid fertilizer tool no no yeshay and forage no no noCapable to read and write implement setup dataimplement type read only read only read onlyimplement model no read only yesimplement name no read only yesconnection type no no yesOffsets no read only yesTurn on/off times no read only yesGPS receiver offsets no no yesphysical width no read only yesimplement width read only read only read onlyturn radius no read only yestrack spacing no read only yesimplement totals no no nolateral offsets of implement sections no read only read only

GS3 2630 DisplayGS3 2630 Display36

Page 39: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

GreenStar 3 CommandCenter Task Controller Capabilities

Capable to communicate (for example for Section Control purposes)spreader John Deere onlysprayer John Deere onlyseeder/planter John Deere onlybaler noliquid fertilizer tool notillage notransport nohay and forage noSection Control capablespreader John Deere onlysprayer John Deere onlyseeder/planter John Deere onlyliquid fertilizer tool nohay and forage noCapable to read implement setup dataimplement type John Deere onlyimplement model noimplement name noconnection type noOffsets noTurn on/off times noGPS receiver offsets nophysical width noimplement width John Deere onlyturn radius notrack spacing noimplement totals John Deere onlylateral offsets of implement sections no

GS3 2630 DisplayGS3 2630 Display37

Page 40: ISOBUS User Guide - John Deere UK & IE · John Deere Tractor (ISOBUS Compatible) Non-Deere Tractor with Six Different Control Units for Non-ISOBUS Implements. GS3 2630 Display User

User GuideUser Guide ISOBUS

GS3 2630 DisplayGS3 2630 Display38