16
1 ISO/IEC SC25 WG3 Who are they & what can they do for 802.3cg? Alan Flatman Principal Consultant LAN Technologies Email: [email protected] Contribution to IEEE 802.3cg Task Force; 09-11 Jan 2017, Huntington Beach, CA

ISO/IEC SC25 WG3 - IEEEgrouper.ieee.org/groups/802/3/cg/public/Jan2017/iec sc25 wg3 overv… · ISO/IEC SC25 WG3 Recent Deliverables Reference Title Approved ISO/IEC TR 24750 Supporting

  • Upload
    others

  • View
    36

  • Download
    1

Embed Size (px)

Citation preview

Page 1: ISO/IEC SC25 WG3 - IEEEgrouper.ieee.org/groups/802/3/cg/public/Jan2017/iec sc25 wg3 overv… · ISO/IEC SC25 WG3 Recent Deliverables Reference Title Approved ISO/IEC TR 24750 Supporting

1

ISO/IEC SC25 WG3

Who are they & what can they do for 802.3cg?

Alan Flatman

Principal Consultant LAN Technologies

Email: [email protected]

Contribution to IEEE 802.3cg Task Force; 09-11 Jan 2017, Huntington Beach, CA

Page 2: ISO/IEC SC25 WG3 - IEEEgrouper.ieee.org/groups/802/3/cg/public/Jan2017/iec sc25 wg3 overv… · ISO/IEC SC25 WG3 Recent Deliverables Reference Title Approved ISO/IEC TR 24750 Supporting

Who are ISO/IEC SC25 WG3?

Ø  International cabling systems group Ø SC25: Interconnection of IT Equipment Ø WG 3: Customer Premises Cabling Ø  active participation by 20 + nations Ø WG3 generally meets twice per year Ø Project Teams may be formed to

accelerate work

2

Contribution to IEEE 802.3cg Task Force; 09-11 Jan 2017, Huntington Beach, CA

Page 3: ISO/IEC SC25 WG3 - IEEEgrouper.ieee.org/groups/802/3/cg/public/Jan2017/iec sc25 wg3 overv… · ISO/IEC SC25 WG3 Recent Deliverables Reference Title Approved ISO/IEC TR 24750 Supporting

ISO/IEC SC25 WG3 Process Model

3

ISO/IEC SC25 WG3 Customer Premises Cabling

IEEE 802 ITU-T ISO/IEC Application Groups

End-to-End Cabling Systems

IEC SC48 Cu Connectors

IEC SC46 Cu Cables

IEC SC86 Optical Comps

Component Groups

CISPR-I EMC

CENELEC TC215

Contribution to IEEE 802.3cg Task Force; 09-11 Jan 2017, Huntington Beach, CA

Alan Flatman Liaison Officer

IEC SC65 JWG10

Page 4: ISO/IEC SC25 WG3 - IEEEgrouper.ieee.org/groups/802/3/cg/public/Jan2017/iec sc25 wg3 overv… · ISO/IEC SC25 WG3 Recent Deliverables Reference Title Approved ISO/IEC TR 24750 Supporting

ISO/IEC SC25 WG3 Recent Deliverables

Reference Title Approved ISO/IEC TR 24750 Supporting 10GBASE-T with Cat 6 2007 ISO/IEC TR 29106 MICE Environmental Classification 2008

ISO/IEC 24702 Am.1 Industrial Cabling 2009

ISO/IEC 15018 Am.1 Home Cabling 2009

ISO/IEC 11801 Ed.2 Customer Premises Cabling: 2010

ISO/IEC 24764 Data Centre Cabling 2010

ISO/IEC TR 29125 Guidelines on Remote Powering 2010

ISO/IEC 14763-2 Cabling Planning & Installation 2011

ISO/IEC TR 11801-9901 Supporting 40GBASE-T with Cat 6A-7A 2014

ISO/IEC 14763-3 Testing of Optical Fibre Cabling 2014

4

Contribution to IEEE 802.3cg Task Force; 09-11 Jan 2017, Huntington Beach, CA

Page 5: ISO/IEC SC25 WG3 - IEEEgrouper.ieee.org/groups/802/3/cg/public/Jan2017/iec sc25 wg3 overv… · ISO/IEC SC25 WG3 Recent Deliverables Reference Title Approved ISO/IEC TR 24750 Supporting

5

Contribution to IEEE 802.3cg Task Force; 09-11 Jan 2017, Huntington Beach, CA

ISO/IEC 11801 Edition 3: Generic Cabling

Ø  existing design standards re-structured into a single family:

Ø  ISO/IEC 11801-1 General Requirements (structure, dimensioning, channel)

Ø  ISO/IEC 11801-2 Commercial Office Premises (unique aspects)

Ø  ISO/IEC 11801-3 Industrial Premises (unique aspects)

Ø  ISO/IEC 11801-4 Residential Premises (unique aspects)

Ø  ISO/IEC 11801-5 Data Centre (unique aspects)

Ø  ISO/IEC 11801-6 Distributed Building Services (unique aspects)

Ø  in final technical stages of a radical revision (FDIS soon) Ø  parts potentially relevant for single-pair application support

Page 6: ISO/IEC SC25 WG3 - IEEEgrouper.ieee.org/groups/802/3/cg/public/Jan2017/iec sc25 wg3 overv… · ISO/IEC SC25 WG3 Recent Deliverables Reference Title Approved ISO/IEC TR 24750 Supporting

6

Contribution to IEEE 802.3cg Task Force; 09-11 Jan 2017, Huntington Beach, CA

ISO/IEC 11801-6: DBS Cabling Scope

1.  Access Controls 2.  Burglar Alarms 3.  Asset Management 4.  Audio-Visual 5.  Building Automation 6.  Building Well-being 7.  Energy Management 8.  Environmental Control 9.  Wireless Access Points 10.  Distributed Antenna Systems en

visa

ged

as o

verla

y in

fras

truc

ture

w

ith O

ffice

IT c

ablin

g (fo

r exa

mpl

e)

Page 7: ISO/IEC SC25 WG3 - IEEEgrouper.ieee.org/groups/802/3/cg/public/Jan2017/iec sc25 wg3 overv… · ISO/IEC SC25 WG3 Recent Deliverables Reference Title Approved ISO/IEC TR 24750 Supporting

7

ISO/IEC 11801-2 Office Cabling Model

Terminal Equipment

campus backbone

cabling

BD FD CP (optional)

TO

building backbone

cabling

horizontal cabling

CD = Campus Distributor BD = Building Distributor FD = Floor Distributor

CP = Consolidation Point TO = Telecoms Outlet

Contribution to IEEE 802.3cg Task Force; 09-11 Jan 2017, Huntington Beach, CA

CD

up to 2,000m

work area

cabling up to 100m

Page 8: ISO/IEC SC25 WG3 - IEEEgrouper.ieee.org/groups/802/3/cg/public/Jan2017/iec sc25 wg3 overv… · ISO/IEC SC25 WG3 Recent Deliverables Reference Title Approved ISO/IEC TR 24750 Supporting

8

ISO/IEC 11801-3 Industrial Cabling Model

campus backbone

cabling

BD FD

building backbone

cabling

floor cabling

CD = Campus Distributor BD = Building Distributor FD = Floor Distributor ID = Intermediate Distributor

CP = Consolidation Point TO = Telecoms Outlet NI = Network Interface

Contribution to IEEE 802.3cg Task Force; 09-11 Jan 2017, Huntington Beach, CA

CD

up to 10,000m

up to 100m

CP (optional)

TO ID

Automation Island

intermediate cabling

NI

Page 9: ISO/IEC SC25 WG3 - IEEEgrouper.ieee.org/groups/802/3/cg/public/Jan2017/iec sc25 wg3 overv… · ISO/IEC SC25 WG3 Recent Deliverables Reference Title Approved ISO/IEC TR 24750 Supporting

9

ISO/IEC 11801-6 Distributed Building Services Cabling Model

Terminal Equipment

campus backbone

cabling

BD SD

SCP SO

building backbone

cabling

service distribution

cabling

CD = Campus Distributor BD = Building Distributor SD = Service Distributor

SCP = Service Concentration Point SO = Service Outlet

Contribution to IEEE 802.3cg Task Force; 09-11 Jan 2017, Huntington Beach, CA

CD

up to 10,000m

service area

cabling

up to 100m

Terminal Equipment

directly attached to TE

Type

A

Type

B

Page 10: ISO/IEC SC25 WG3 - IEEEgrouper.ieee.org/groups/802/3/cg/public/Jan2017/iec sc25 wg3 overv… · ISO/IEC SC25 WG3 Recent Deliverables Reference Title Approved ISO/IEC TR 24750 Supporting

v  Return Loss v  Insertion Loss v  NEXT v  ACR-N v  ACR-F v  DC Resistance v  DC Current Capacity v  Dielectric Withstand v  Propagation Delay v  TCL v  ELTCTL v  Coupling Attenuation v  Alien Crosstalk

ISO/IEC 11801 Edition 3: Balanced Cabling Parameters

10

Contribution to IEEE 802.3cg Task Force; 09-11 Jan 2017, Huntington Beach, CA

Page 11: ISO/IEC SC25 WG3 - IEEEgrouper.ieee.org/groups/802/3/cg/public/Jan2017/iec sc25 wg3 overv… · ISO/IEC SC25 WG3 Recent Deliverables Reference Title Approved ISO/IEC TR 24750 Supporting

Category 5 cable, connector and cord specified up to 100MHz

Category 6 cable, connector and cord specified up to 250MHz

Category 6A cable, connector and cord specified up to 500MHz

Category 7 cable, connector and cord specified up to 600MHz

Category 7A cable, connector and cord specified up to 1000MHz

Category 8.1 cable, connector and cord specified up to 2,000MHz

Category 8.2 cable, connector and cord specified up to 2,000MHz

ISO/IEC 11801 Edition 3: Balanced Cabling Categories

11

Contribution to IEEE 802.3cg Task Force; 09-11 Jan 2017, Huntington Beach, CA

Page 12: ISO/IEC SC25 WG3 - IEEEgrouper.ieee.org/groups/802/3/cg/public/Jan2017/iec sc25 wg3 overv… · ISO/IEC SC25 WG3 Recent Deliverables Reference Title Approved ISO/IEC TR 24750 Supporting

ISO/IEC 11801 Edition 3: Balanced Cabling Classes 12

Contribution to IEEE 802.3cg Task Force; 09-11 Jan 2017, Huntington Beach, CA

Class A

Class B

Class C

Class D

Class E

Class EA

Class F

Class FA

Class I

Class II

Upper Freq 100m + 4 connections

30m + 2 connections

>100m + >4 connections

100KHz

1MHz

16MHz

100MHz

250MHz

500MHz

600MHz

1,000MHz

2,000MHz

2,000MHz

yes

yes

no

no

yes

yes

yes

yes

no

no

2,000m

250m

170m

105m

no

no

no

no h

oriz

onta

l cab

ling

bac

kbon

e ca

blin

g

Page 13: ISO/IEC SC25 WG3 - IEEEgrouper.ieee.org/groups/802/3/cg/public/Jan2017/iec sc25 wg3 overv… · ISO/IEC SC25 WG3 Recent Deliverables Reference Title Approved ISO/IEC TR 24750 Supporting

ISO/IEC 11801 Cable Construction

13

Twisted pairs

Inner foil sheaths

Braid

Outer foil sheath

UTP

F/UTP

S/FTP

Note: ISO/IEC 11801 does not specify cable construction

Contribution to IEEE 802.3cg Task Force; 09-11 Jan 2017, Huntington Beach, CA

Page 14: ISO/IEC SC25 WG3 - IEEEgrouper.ieee.org/groups/802/3/cg/public/Jan2017/iec sc25 wg3 overv… · ISO/IEC SC25 WG3 Recent Deliverables Reference Title Approved ISO/IEC TR 24750 Supporting

ISO/IEC 11801 Edition 3 Outlets

14

ISO/IEC 11801 specifies the following connectors: IEC 60603-7-xx (RJ45) for Cat 5 - 8.1 IEC 60603-7-82 (GG45) for Cat 8.2 IEC 61076-3-104 (Tera) allowed alternative for Cat 7A or Cat 8.2 when backwards compatibility is not required

Contribution to IEEE 802.3cg Task Force; 09-11 Jan 2017, Huntington Beach, CA

Tera GG45 to GG45 RJ45 to GG45 RJ45 to GG45 with switch 4-

pair

outle

t con

figur

atio

n re

com

men

ded

how

ever

2-p

air c

onfig

urat

ion

is a

llow

ed

Page 15: ISO/IEC SC25 WG3 - IEEEgrouper.ieee.org/groups/802/3/cg/public/Jan2017/iec sc25 wg3 overv… · ISO/IEC SC25 WG3 Recent Deliverables Reference Title Approved ISO/IEC TR 24750 Supporting

ISO/IEC 11801 Edition 3: Environmental Classification

Mechanical Rating

Ingress Rating

Climatic Rating

Electromagnetic Rating

M1

I1

C1

E1

1

M2

I2

C2

E2

2

M3

I3

C3

E3

3

Examples: M1I1C1E1, M1I3C2E2, M3I3C3E3

15

Contribution to IEEE 802.3cg Task Force; 09-11 Jan 2017, Huntington Beach, CA

Page 16: ISO/IEC SC25 WG3 - IEEEgrouper.ieee.org/groups/802/3/cg/public/Jan2017/iec sc25 wg3 overv… · ISO/IEC SC25 WG3 Recent Deliverables Reference Title Approved ISO/IEC TR 24750 Supporting

16

Cabling to Support 1-pair Applications

Ø  new project agreed in Sep 2016 to define a single-pair channel to 600MHz to support IEEE 802.3bp 40m Type B link segment

Ø  ISO/IEC Technical Report to be developed

Ø  agreed in Sep 2016 to revise ISO/IEC 11801-6 to define support of 1 pair applications, including:

Ø  building controls Ø  access control Ø  audio-visual Ø  security Ø  Internet of Things Ø  amendment to ISO/IEC 11801-6 to be developed

Contribution to IEEE 802.3cg Task Force; 09-11 Jan 2017, Huntington Beach, CA