2
1 UCSB Isolated Bad CAC Bonding Bonding Meeting-21/10/03 Isolated Bad-CAC Strip at UCSB For first 57 modules produced at UCSB, there was a slight misunderstanding of bonding rules Bonded isolated Bad CAC channel that were not also marked as a bad IDIEL channel 23 of 57 modules had at least one such channel 42 channels total Plucking channels would result in a few more Grade B modules Not a large concern 0 5 10 15 20 25 30 35 40 0 1 2 3 4 5 Num berofFaults Number of Modules

Isolated Bad-CAC Strip at UCSB

Embed Size (px)

DESCRIPTION

Isolated Bad-CAC Strip at UCSB. For first 57 modules produced at UCSB, there was a slight misunderstanding of bonding rules Bonded isolated Bad CAC channel that were not also marked as a bad IDIEL channel 23 of 57 modules had at least one such channel 42 channels total - PowerPoint PPT Presentation

Citation preview

Page 1: Isolated Bad-CAC Strip at UCSB

1UCSB Isolated Bad CAC Bonding Bonding Meeting-21/10/03

Isolated Bad-CAC Strip at UCSB• For first 57 modules

produced at UCSB, there was a slight misunderstanding of bonding rules Bonded isolated Bad CAC

channel that were not also marked as a bad IDIEL channel

• 23 of 57 modules had at least one such channel 42 channels total

• Plucking channels would result in a few more Grade B modules Not a large concern

0

5

10

15

20

25

30

35

40

0 1 2 3 4 5

Number of Faults

Num

ber o

f Mod

ules

Page 2: Isolated Bad-CAC Strip at UCSB

2UCSB Isolated Bad CAC Bonding Bonding Meeting-21/10/03

Testing Results on Isolated Bad CAC Strips

• All modules have been fully tested with ARCS and LT system Both pulsed and

continuous LED tests taken

• ALL of the 42 strips had regular test results (passed) No problem seen with

these channels

CAC@ 100 Hz measured (in pF) at QTC

0

1

2

3

4

5

6

7

8

9

-50 50 15

0250

350

450

550

650

800

900

1000

1100

CAC@ 100 Hz

Nu

mb

er

of

Ch

an

ne

ls

Yes, that’s negative capacitance!!!