Data sheet isovac 600-50 A | page 1/7 | 01/2018
isovac 600-50 A
Manufactured in the most modern production lines, this fully processed isovac® grade exhibits highly homogeneous properties across the width and length of the entire strip. The result is excellent and consistent processability in the manufacture of highly efficient electrical components.Upon request, isovac 600-50 A can be supplied with an electrical steel insulation system and can be used directly in as-delivered condition.
Convincing advantages: » Best processability through consistent mechan-ical properties and homogeneous, clean sur-faces
» Excellent stackability resulting from high dimen-sional accuracy in rolling direction and perpen-dicular to rolling direction (thickness tolerance)
» Innovative electrical steel insulation systems upon request
The perfect solution for direct application
Electrical Steel | Fully processed Data sheet isovac 600-50 A | page 1/7 | 01/2018
voestalpine Steel Division www.voestalpine.com/isovac
Data sheet isovac 600-50 A | page 2/7 | 01/2018
Grade namedaccording to isovac®
DIN EN 10106 IEC60404-8-4
JISC2552
GOST21427.2
ASTMA677
AISI IS648 GB/T2521.1Material No. Abbreviation
isovac 600-50 A 1.0814 M600-50A M600-50A 5 50A600 2112 - - 50C600 50W600
Grade named according to conventional international standards:
Grade named according to isovac®
Yield strength ReH
[MPa]
0.2 %-Yield strength Rp0.2
[MPa]
Tensile strength Rm
[MPa]
ElongationA80 [%]
HardnessHV5
[-]
isovac 600-50 A 335 310 450 35 135
Mechanical properties: Tensile test according to DIN EN ISO 6892-1 and hardness according to DIN EN ISO 6507-1 (Typical values); Test direction: Transverse
Specific total loss Magnetic polarization Relative permeability
Grade namedaccording to isovac®
1.0 T P10
1.5 TP15
2500 A/mJ25
5000 A/mJ50
10000 A/mJ100
1.5 Tµr
50 Hz[W/kg]
60 Hz[W/lb]
50 Hz[W/kg]
60 Hz[W/lb] [T] [T] [T] [-]
isovac 600-50 A 2.20 1.25 4.80 2.74 1.64 1.72 1.84 2500
Magnetic properties: in as-delivered condition (Typical values)Test direction: Mean value from longitudinal and transverse measurements at 50 Hz (60 Hz), single-sheet test
Grade named according to isovac®
Densityρ
[g/cm3]
Specific electrical resistanceρs
[µΩcm]
Thermal conductivityλ
[W/mK]
isovac 600-50 A 7.78 31.1 36
Physical properties: Typical values
voestalpine supplies isovac 600-50 A, an electrical steel of the highest quality. We offer you a customer-focused overall package of products, service and logistics in addition to all the advantages of our integrated metallurgical facility and Steel Service Centers.
Data sheet isovac 600-50 A | page 3/7 | 01/2018
Characteristics Ps/J loss curve and characteristics J/H magnetization curveTest direction: Mean value from longitudinal and transverse measurements at indicated frequencies, single-sheet test
Characteristics µr/J permeability curveTest direction: Mean value from longitudinal and transverse measurements at 50 Hz, single-sheet test
0.0
0.1
1.0
10.0
100.0
1000.0
0 500 1000 1500
P S [W
/kg]
J [mT]
50 Hz 60 Hz 200 Hz 400 Hz 500 Hz 600 Hz 700 Hz 800 Hz 1000 Hz
0
1000
2000
3000
4000
5000
6000
7000
0 500 1000 1500 2000
µ r
J [mT]
50 Hz
0
200
400
600
800
1000
1200
1400
1600
1800
10 100 1000 10000
J [mT]
H [A/m]
50 Hz
Data sheet isovac 600-50 A | page 4/7 | 01/2018
Frequency dependence of magnetic propertiesTest direction: Mean value longitudinal and transverse at indicated frequencies and polarizations, single-sheet test
50 Hz 60 Hz 200 Hz
J [mT]
H[A/m]
Ps[W/kg]
µr[-]
J [mT]
H[A/m]
Ps[W/kg]
µr[-]
J [mT]
H[A/m]
Ps[W/kg]
µr[-]
100 53 0.03 1534 100 54 0.18 1491
150 59 0.10 1904 150 59 0.12 1890 150 63 0.55 1772
200 65 0.17 2272 200 66 0.20 2237 200 71 0.93 2049
250 71 0.24 2632 250 72 0.29 2579 250 79 1.32 2320
300 76 0.32 2983 300 78 0.37 2914 300 87 1.73 2581
350 82 0.40 3321 350 84 0.47 3239 350 95 2.18 2829
400 87 0.48 3643 400 90 0.57 3553 400 103 2.66 3061
450 93 0.57 3945 450 95 0.68 3852 450 110 3.19 3274
500 97 0.67 4224 500 100 0.80 4135 500 117 3.77 3463
550 102 0.78 4478 550 104 0.93 4399 550 124 4.41 3627
600 106 0.90 4708 600 108 1.07 4643 600 131 5.12 3765
650 110 1.02 4917 650 112 1.22 4868 650 138 5.90 3877
700 114 1.16 5107 700 115 1.38 5074 700 145 6.75 3964
750 118 1.29 5280 750 119 1.55 5259 750 152 7.68 4025
800 123 1.44 5438 800 123 1.73 5425 800 161 8.69 4060
850 127 1.58 5583 850 128 1.91 5570 850 170 9.78 4071
900 132 1.74 5708 900 132 2.10 5695 900 180 10.96 4062
1000 144 2.07 5876 1000 144 2.52 5880 1000 202 13.59 4006
1050 150 2.25 5909 1050 150 2.74 5938 1050 213 15.04 3969
1100 158 2.44 5911 1100 157 2.98 5964 1100 225 16.59 3926
1150 167 2.64 5883 1150 166 3.23 5952 1150 238 18.24 3878
1200 178 2.85 5805 1200 175 3.50 5925 1200 251 20.02 3831
1250 191 3.08 5642 1250 186 3.80 5877 1250 263 21.94 3784
1300 212 3.33 5332 1300 203 4.12 5685 1300 279 24.00 3721
1350 245 3.59 4818 1350 232 4.46 5219 1350 305 26.24 3604
1400 295 3.88 4075 1400 280 4.85 4424 1400 336 28.77 3352
1450 383 4.20 3126 1450 368 5.29 3327 1450 392 31.65 2889
1500 594 4.56 2145 1500 586 5.76 2198 1500 582 34.61 2221
1550 1033 4.93 1318 1550 1041 6.20 1310 1550 1035 37.39 1414
1600 1815 5.30 727 1600 1857 6.62 714 1600 1863 40.22 713
1650 3009 5.63 401 1650 3113 7.04 390 1650 3128 43.34 332
1700 4504 5.94 268 1700 4694 7.45 257 1700 4714 46.70 211
Data sheet isovac 600-50 A | page 5/7 | 01/2018
Frequency dependence of magnetic propertiesTest direction: Mean value longitudinal and transverse at indicated frequencies and polarizations, single-sheet test
400 Hz 500 Hz 600 Hz
J [mT]
H[A/m]
Ps[W/kg]
µr[-]
J [mT]
H[A/m]
Ps[W/kg]
µr[-]
J [mT]
H[A/m]
Ps[W/kg]
µr[-]
100 62 0.71 1292 100 64 0.93 1246
150 69 1.42 1602 150 72 1.95 1511 150 75 2.47 1449
200 79 2.36 1829 200 83 3.24 1726 200 86 4.06 1648
250 89 3.35 2048 250 94 4.59 1931 250 98 5.77 1836
300 100 4.41 2253 300 105 6.06 2122 300 109 7.64 2010
350 110 5.58 2440 350 116 7.68 2293 350 122 9.74 2163
400 120 6.87 2606 400 128 9.48 2440 400 135 12.12 2291
450 131 8.31 2745 450 140 11.50 2558 450 149 14.84 2389
500 142 9.93 2854 500 153 13.78 2642 500 164 17.95 2452
550 153 11.76 2929 550 166 16.35 2689 550 181 21.51 2478
600 165 13.81 2972 600 181 19.26 2702 600 198 25.55 2470
650 177 16.10 2988 650 196 22.56 2689 650 217 30.10 2436
700 191 18.66 2980 700 213 26.28 2653 700 238 35.21 2385
750 205 21.50 2953 750 232 30.48 2601 750 260 40.90 2322
800 222 24.66 2909 800 253 35.19 2538 800 283 47.22 2256
850 240 28.14 2852 850 275 40.44 2470 850 309 54.19 2192
900 259 31.96 2788 900 299 46.20 2401 900 336 61.89 2130
1000 301 40.64 2654 1000 350 59.04 2276 1000 397 79.79 2008
1050 323 45.53 2591 1050 376 66.11 2224 1050 430 90.12 1947
1100 347 50.84 2530 1100 404 73.86 2171 1100 464 101.31 1887
1150 372 56.65 2468 1150 434 82.48 2111 1150 500 113.34 1832
1200 397 62.90 2408 1200 466 91.85 2052 1200 537 126.27 1780
1250 421 69.57 2351 1250 497 101.89 1999 1250 575 140.26 1729
1300 452 76.71 2293 1300 534 112.98 1938 1300 616 155.58 1679
1350 490 84.47 2231 1350 579 125.28 1866 1350 660 172.38 1629
1400 513 93.23 2173 1400 610 137.79 1828 1400 705 190.14 1580
1450 525 103.16 2096 1450 621 150.52 1830 1450 753 209.13 1532
1500 659 113.55 1835 1500 717 168.73 1667 1500 812 233.19 1471
1550 1073 123.75 1285
1600 1878 134.49 705
1650 3135 146.53 367
1700 4722 159.61 240
Data sheet isovac 600-50 A | page 6/7 | 01/2018
Frequency dependence of magnetic propertiesTest direction: Mean value longitudinal and transverse at indicated frequencies and polarizations, single-sheet test
700 Hz 800 Hz 1000 Hz
J [mT]
H[A/m]
Ps[W/kg]
µr[-]
J [mT]
H[A/m]
Ps[W/kg]
µr[-]
J [mT]
H[A/m]
Ps[W/kg]
µr[-]
100 66 1.17 1211 100 68 1.45 1167 100 74 2.18 1082
150 78 3.06 1397 150 81 3.72 1335 150 88 5.30 1229
200 90 5.03 1577 200 94 6.08 1499 200 102 8.55 1371
250 102 7.14 1748 250 107 8.63 1654 250 118 12.10 1505
300 115 9.48 1905 300 121 11.48 1795 300 133 16.07 1626
350 128 12.11 2041 350 136 14.71 1917 350 151 20.63 1730
400 143 15.12 2154 400 152 18.42 2016 400 169 25.90 1812
450 159 18.57 2237 450 170 22.71 2088 450 190 32.03 1867
500 176 22.54 2287 500 189 27.68 2126 500 212 39.17 1893
550 194 27.11 2299 550 210 33.42 2130 550 238 47.47 1885
600 214 32.31 2281 600 233 40.00 2104 600 265 57.06 1850
650 236 38.22 2238 650 257 47.47 2055 650 296 68.09 1794
700 260 44.86 2179 700 284 55.91 1992 700 329 80.71 1725
750 285 52.31 2110 750 314 65.37 1922 750 365 95.07 1650
800 313 60.59 2040 800 345 75.92 1851 800 405 111.30 1576
850 343 69.78 1975 850 378 87.63 1786 850 448 129.53 1508
900 374 79.94 1914 900 414 100.58 1727 900 494 149.82 1448
1000 443 103.44 1798 1000 492 130.57 1617 1000 593 196.62 1343
1050 480 116.94 1741 1050 535 147.80 1565 1050 645 223.21 1296
1100 520 131.64 1686 1100 579 166.61 1513 1100 699 252.07 1252
1150 560 147.57 1634 1150 625 187.08 1465 1150 755 283.32 1212
1200 603 164.76 1585 1200 673 209.12 1420 1200 814 317.00 1173
1250 647 183.32 1537 1250 723 232.82 1376 1250 877 353.04 1135
1300 694 203.57 1491 1300 775 259.01 1335 1300 941 391.10 1100
1350 743 225.75 1446 1350 831 287.98 1294 1350 1005 431.20 1068
1400 795 249.32 1402 1400 888 317.43 1255 1400 1076 475.20 1035
1450 850 274.72 1357 1450 950 347.49 1213 1450 1159 524.28 997
1500 917 306.76 1301 1500 1034 390.42 1154 1500 1232 574.89 969
Data sheet isovac 600-50 A | page 7/7 | 01/2018
voestalpine Stahl GmbH voestalpine-Straße 34020 Linz, AustriaT. +43/50304/[email protected]/isovac
The information and product properties contained in this printed material are non-binding and serve the sole purpose of technical orientation. They do not replace individual advisory services provided by our sales and customer service teams. The product information and characteristics set forth herein shall not be considered as guaranteed properties unless explicitly stipulated in a separate contractual agreement. For this reason, voestalpine shall not grant any warranty nor be held liable for properties and/or specifications other than those subject to explicit agreement. This also applies to the suitability and applicability of products for certain applications as well as to the further processing of materials into final products. All application risks and suitability risks shall be borne by the customer. The General Terms of Sale for Goods and Services of the voestalpine Steel Division shall apply to all materials supplied by the voestalpine Steel Division and can be accessed using the following link: www.voestalpine.com/stahl/en/The-Steel-Division/General-Terms-of-Sale
Technical changes are reserved. Errors and misprints are excepted. No part of this publication may be reprinted without explicit written permission by voestalpine Stahl GmbH.
Please find further information and downloadable files at
www.voestalpine.com/isovac
Available Dimensions
Grade namedaccording to isovac®
Delivery form Width[mm]
Length[mm]
isovac 600-50 AWide strip / Slit strip 19 – 1590 -
Cut-to-length sheets 300 – 1590 300 – 5000
Grade namedaccording to isovac®
Uncoated C-3 Backlack C-5 C-6
isovac 600-50 A
Deliverable coating systems
Available On request