Total Solution for Gas & Liquid Metering Honeywell’s ISSplus software provides a total solution for gas and liquid metering, including stations from a single stream up to 100 streams, control systems for high-pressure calibration facilities and remote metering applications.
Proven Technology. Superior Performance. Honeywell’s ISSplus measurement and control system
for metering installations combines more than
20 years of experience in automation of bulk gas
control and monitoring with the latest technologies.
It can consist of a single supervisory computer or
redundant configurations with or without client
stations. This solution fully integrates Honeywell’s
Elster® products, providing synergy with the Meascon™
Condition-based Monitoring (CBM) system.
ISSplus brings unique advantages to gas operations:
• Secure automated control and monitoring of
critical metering functions
• Advanced redundancy and data synchronization
features for the highest availability
• Superior calculation, data processing, reporting,
trending and communication capabilities.
Rundandant System Configurations A redundant supervisory system is often required
for high availability. With the ISSplus solution, both
supervisory computers will have their own SQL server
for data. This data is synchronized between both
the duty and backup server to ensure it is identical.
The duty supervisory computer communicates
with all devices and distributes the readings to
the connected backup server, which performs a
background communication check only. For
situations where multiple operator terminals are
required, a true redundant client server system
is offered. Client stations allow process graphics
to be visible on the company network, and
are available in two variants: view only (view
station) and full operation (operator station).
Total Solution Display
Intuitive Human-Machine Interface (HMI) Advanced graphics with the ISSplus software
provide a convenient overview of the metering
station. This includes process data such as flow
rates, pressures and temperatures. Overview
screens give you all the necessary information to
check your metering system at a glance but
without overloading operators with too much
information. Intuitive detailed screens and touch
screen accessibility offer additional information for
diagnostic and fault finding purposes. Operation
is easy using mouse and function keys. Security
levels can restrict access to all parts of the system.
Flexible Reporting & Billing ISSplus will process data from flow computers with
utmost precision—ensuring data processing
without rounding errors. The values are stored in
a SQL database. Standard systems include daily
and monthly production reports, but any report can
be made available. The daily report, for example,
includes hourly and daily production values
in tabular format. Reports can be automatically
printed and are also stored on disk. In addition,
users of the ISSplus solution can do reporting with
a third-party reporting tool, allowing maximum
flexibility in report generation. On top of that, there
is a possibility to store data in external databases
or export the data/reports in Excel or PDF format
for further processing.
Robust DiagnosticsThe robust performance monitoring features
within ISSplus were developed in close cooperation
with design specialists for Honeywell’s Elster group
products such as the Q.Sonic ultrasonic meter,
Encal 3000 gas chromatograph and enCore FC1
flow computer. The software continuously monitors
process conditions and validates metering system
performance. It will signal if metering equipment has
drifted and requires maintenance or recalibration.
Powerful CBM Capabilities Honeywell’s CBM system, Meascon, fully integrates
Honeywell’s Elster products to take performance
to the next level. Meascon enables gas operators
to implement effective preventive maintenance
strategies and minimize instrument calibration
requirements to reduce their operating expenses
(OPEX). The system allows for easy health
monitoring of a complete metering system and, in
particular, ultrasonic gas flow meters from Honeywell.
Users can achieve reliability, long-term measurement
accuracy and minimum uncertainty while keeping
maintenance costs as low as possible. Powerful
CBM capabilities detect any significant change
either in the flow meter itself, or the process and
environment in which it is operating, so operators
can take appropriate action.
Performance Display
ISSplus Delivers • Advanced technologies
for demanding metering requirements
• Proven industry domain expertise
• Flexible configurations for any size installation
• ISSplus Supervisory Software
SVC 1
SVC 1
Duty
Standby
SVC 2
SVC 1
Duty
Standby
Operator Station
View Station
View Station
Production LAN
SVC 2
For more informationTo learn more about Honeywell’s ISSplus software,
visit www.honeywellprocess.com or contact your
Honeywell account manager.
Honeywell Process Solutions Honeywell House, Arlington Business Park
Bracknell, Berkshire, England RG12 1EB
1250 West Sam Houston Parkway South
Houston, TX 77042 USA Tel: +1 832 252 3000
33F, Tower A, Shanghai City Centre
100 Zunyi Road, Shanghai, China 200051
www.honeywellprocess.com
Germany Elster GmbH Steinern Straße
19-21 55252 Mainz-Kastel
www.elster.com
Elster® is a registered trademark, and Meascon™ is a trademark of Honeywell International Inc. *All other trademarks are the property of their respective owners.
BR-16-51-ENG | 02/17 ©2017 Honeywell International Inc.
Minimum System Requirements: • OS: Microsoft
Windows 7 (32-bit)
• Program: Microsoft Excel 2010
• Processor:2.8 GHz i5
• Memory: 1 GB
Trend Display
• Easy configuration
• Real-time calculation and communication
• Real-time reporting & billing
• Tools for effective and efficient maintenance
• Server/Client solutions
• Run switching and proving
• Diagnostics
• Ultrasonic flowmeters (velocity of sound, Meascon)
• Filter blockage
• Meter lubrication
• Metering calculations:
— Compressibility in accordance with SGERG,
AGA-8, AGA NX19
— Velocity of sound acc. AGA-10
— Orifice/venturi calculations acc. ISO5167, AGA-3
— Energy calculations acc. ISO6976, AGA-5,
GPA 2172
• Built-in trending for process analysis
• Advanced alarm and event logging
• E-mail or SMS generation on alarms or events
• Validation/calibration system with database
and control charts
• Extensive protocol support: Modbus RTU/TCP/
IP, HART, OPC, XML, etc.
• Integrated performance monitoring for
Honeywell’s Elster equipment.
Honeywell ISSplus Software is Recognized for Unsurpassed Flexibility and Ease of Use