2
SERENITY SERIES CUBER ICE MACHINE Item #: Project: Qty: AIA#: 618 Hwy, 74 S., Peachtree City, GA 30269 | TEL 800-438-6087 | FAX 800-345-1325 | www.hoshizakiamerica.com © HOSHIZAKI AMERICA, INC. KM Cube Dimensions* * approximate size in inches, image not to scale Features Remote Air-Cooled Shown on optional Lancer 30” Dispenser KMS-2000MLH Individual crescent cube Stainless steel evaporator CycleSaver TM design TM Ambient Temp Range 45 - 100°F Water Temp Range 45 - 90°F Water Pressure 10 - 113 PSIG Voltage Range 187-253V* Operating Limits- Icemaker Water Supply Line: Minimum 3/8” Nominal ID Copper Water Tubing or Equivalent Icemaker Drain Line: Minimum 3/4” Nominal ID Hard Pipe or Equivalent Allow 24” (61 cm) clearance in both front and rear for proper air circulation and ease of maintenance/service. For best performance the Remote Condenser should not be more than 33 feet above the icemaker or no more than 10 feet below it. These distances are measure from fitting to fitting. Plumbing- Allow 6” (15 cm) clearance at rear and sides for proper air circulation for ease of maintentance and/or service should they be required. Panels easily removed and all components accessible for service. Service- 30" x 24" x 32 7/8 " W x D x H Hoshizaki reserves the right to change specifications without notice. Printed in the U.S.A. 3 Year Parts & Labor on entire machine. 5 Year Parts & Labor on Evaporator. 5 Year Parts on Compressor; air-cooled condenser coil. Valid in United States, Canada, Puerto Rico and U.S. Territories. Contact factory for warranty in other countries. Warranty: Air / Water Temp Lbs. per 24 hours Condenser Model 70°/ 50°F 90°/ 70°F ICE PRODUCTION Per Cycle Lbs. Cubes Potable Gal. per 100 lbs. Condenser Gal. per 100 lbs. Max. Fuse Size or HACR Circuit Breaker Heat Rejection BTU/hr. Shipping Weight Voltage ENERGY STAR ® WATER USAGE 90°/ 70°F 90°/ 70°F ELECTRICAL 90°/ 70°F kWh Used per 100 lbs. Amperage 1861 KMS-2000MLH 1786 27.9 1560 4.70 4.65 22.0 23.3 N/A N/A 30A 37,300 36,000 206 lbs. 115V/60/1* Remote Air-Cooled 21.3A KMS-2000MLH KMS-2000MLH 07/12/18 Item # 13283 SRK-20H / SRK-20H3 Installation Dimension* SRK-20H / SRK-20H3 Actual Dimension 25’ Length Condenser Model LINE SETS - Brazing Required 35’ Length 55’ Length Max. Fuse Size or HACR Circuit Breaker Heat Rejection BTU/hr. Shipping Weight Voltage ENERGY STAR ® ELECTRICAL Ambient Amperage SRK-20H HS-0243** HS-0244** -20 - 122° HS-0245** 30A 37,300 325 lbs. 208-230V/60/1 Remote 21.3A SRK-20H3 20A 36,000 325 lbs. 208-230V/60/3 Remote 11.0A (Outdoor Use) -20 - 122° 62” x 21" x 45" 59 11/16 ” x 17” x 30” *Dimensions include legs Voltage Range 187-253VAC 187-253VAC KMS-2000MLH KMS-2000MLH KMS-2000MLH TEMP RANGE ** line sets require refrigerant Service- SRK-20H(3) Remote Air-Cooled with SRK-20H with SRK-20H3 1910 1706 27.4 1560 20A 11.0A 115V/60/1* 206 lbs. * Voltage supply for KMS Ice Maker is supplied from the SRK Remote Condenser KMS-2000MLH HS-0243** HS-0244** HS-0245** * Voltage supply for KMS Ice Maker is supplied from the SRK Remote Condenser Up to 1910 lbs. of ice production per 24 hours Ice on beverage design Durable stainless steel exterior Protected by H-GUARD Plus Antimicrobial Agent EverCheck TM alert system Less heat in the kitchen Minimized noise CFC / HFC Free Foam R-404A Refrigerant ®

Item # 13283 · 2018. 7. 19. · Item # 13283 59 9/16 19 1/2 45 Tubing Kits - Requires Field Brazing (Sold Separately) 25’ HS-0243 35’ HS-0244 55’ HS-0245 Voltage supply for

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Item # 13283 · 2018. 7. 19. · Item # 13283 59 9/16 19 1/2 45 Tubing Kits - Requires Field Brazing (Sold Separately) 25’ HS-0243 35’ HS-0244 55’ HS-0245 Voltage supply for

SERENITY SERIES CUBER ICE MACHINEItem #:

Project:

Qty:

AIA#:

618 Hwy, 74 S., Peachtree City, GA 30269 | TEL 800-438-6087 | FAX 800-345-1325 | www.hoshizakiamerica.com© HOSHIZAKI AMERICA, INC.

KM Cube Dimensions*

* approximate size in inches, image not to scale

Features

Remote Air-CooledShown on optional

Lancer 30” Dispenser

KMS-2000MLH

Individual crescent cube

Stainless steel evaporator

CycleSaverTM design TM

• Ambient Temp Range 45 - 100°F• Water Temp Range 45 - 90°F• Water Pressure 10 - 113 PSIG• Voltage Range 187-253V*

Operating Limits-• Icemaker Water Supply Line: Minimum 3/8” Nominal ID Copper Water Tubing or Equivalent• Icemaker Drain Line: Minimum 3/4” Nominal ID Hard Pipe or Equivalent

• Allow 24” (61 cm) clearance in both front and rear for proper air circulation and ease of maintenance/service.• For best performance the Remote Condenser should not be more than 33 feet above the icemaker or no more than 10 feet below it. These distances are measure from fitting to fitting.

Plumbing-

• Allow 6” (15 cm) clearance at rear and sides for proper air circulation for ease of maintentance and/or service should they be required.• Panels easily removed and all components accessible for service.

Service-

30" x 24" x 327/8"W x D x H

Hoshizaki reserves the right to change specifications without notice.Printed in the U.S.A.

3 Year Parts & Labor on entire machine. 5 Year Parts & Labor on Evaporator. 5 Year Parts on Compressor; air-cooled condenser coil. Valid in United States, Canada, Puerto Rico and U.S. Territories. Contact factory for warranty in other countries.

Warranty:

Air / Water TempLbs. per 24 hoursCondenser Model

70°/ 50°F 90°/ 70°F

ICE PRODUCTIONPer Cycle

Lbs. Cubes

Potable Gal. per 100 lbs.

Condenser Gal. per 100 lbs.

Max. Fuse Sizeor HACR

Circuit Breaker

HeatRejectionBTU/hr.

ShippingWeightVoltage

ENERGYSTAR®

WATER USAGE

90°/ 70°F 90°/ 70°F

ELECTRICAL

90°/ 70°F

kWh Used per 100 lbs. Amperage

1861KMS-2000MLH 1786 27.9 1560 4.70

4.65

22.0

23.3

N/A

N/A

30A 37,300

36,000

206 lbs.115V/60/1*Remote Air-Cooled 21.3A

KMS-2000MLHKMS-2000MLH

07/12/18Item # 13283

SRK-20H / SRK-20H3Installation Dimension*

SRK-20H / SRK-20H3Actual Dimension

25’ LengthCondenser Model

LINE SETS - Brazing Required

35’ Length 55’ LengthMax. Fuse Size

or HACRCircuit Breaker

HeatRejectionBTU/hr.

ShippingWeightVoltage

ENERGYSTAR®

ELECTRICALAmbient Amperage

SRK-20H HS-0243** HS-0244** -20 - 122°HS-0245** 30A 37,300 325 lbs.208-230V/60/1Remote 21.3A

SRK-20H3 20A 36,000 325 lbs.208-230V/60/3Remote 11.0A

(Outdoor Use)

-20 - 122°

62” x 21" x 45"

5911/16” x 17” x 30”

*Dimensions include legs

VoltageRange

187-253VAC

187-253VAC

KMS-2000MLH KMS-2000MLH

KMS-2000MLH

TEMP RANGE

** line sets require refrigerant

Service- SRK-20H(3)

Remote Air-Cooledwith SRK-20H

with SRK-20H3 1910 1706 27.4 1560 20A 11.0A 115V/60/1* 206 lbs.

* Voltage supply for KMS Ice Maker is supplied from the SRK Remote Condenser

KMS-2000MLH

HS-0243** HS-0244** HS-0245**

* Voltage supply for KMS Ice Maker is supplied from the SRK Remote Condenser

• Up to 1910 lbs. of ice production per 24 hours

• Ice on beverage design

• Durable stainless steel exterior

• Protected by H-GUARD Plus Antimicrobial Agent

• EverCheckTM alert system

• Less heat in the kitchen

• Minimized noise

• CFC / HFC Free Foam

• R-404A Refrigerant

®

Page 2: Item # 13283 · 2018. 7. 19. · Item # 13283 59 9/16 19 1/2 45 Tubing Kits - Requires Field Brazing (Sold Separately) 25’ HS-0243 35’ HS-0244 55’ HS-0245 Voltage supply for

618 Hwy, 74 S., Peachtree City, GA 30269 | TEL 800-438-6087 | FAX 800-345-1325 | www.hoshizakiamerica.com© HOSHIZAKI AMERICA, INC.

BOTT

OM V

IEW

REAR

VIE

WSI

DE V

IEW

FRON

T VI

EW

Printed in the U.S.A.

REMOTE AIR-COOLED

REMOTE AIR-COOLED

Front

REMOTE AIR-COOLED

REMOTE AIR-COOLED

SRK-20H(3) REMOTE CONDENSER

SRK-20H(3) REMOTE CONDENSER

TOP

VIEW

SRK-20H(3) Remote Condenser (Sold Separately)(W x D x H) 599/16 x 191/2 x 45

For Use with KMS-2000MLH(3)Front

SERENITY SERIES CUBER ICE MACHINE

SRK-20H(3) REMOTE CONDENSER

mm[inches]

KMS-2000MLHKMS-2000MLH

07/12/18Item # 13283

59 9/16

19 1/2

45

Tubing Kits - Requires Field Brazing(Sold Separately)25’ HS-024335’ HS-024455’ HS-0245Voltage supply for the KMS Ice Makeris supplied from the SRK Remote Condenser.

For best performanceallow 24 inch clearancefor air cirulation.