52
ELEVATION TAG SECTION TAG NORTH DETAIL TAG DOOR TAG 1 A-1 1 A-1 1 A-1 NORTH SHOWS DIRECTION OF MAGNETIC NORTH DENOTES WALL TYPE. SEE 1/ A-5 NUMBER DENOTES DOOR REFERENCE TO DOOR SCHEDULE. SEE A-1 TOP = SECTION NUMBER BOTTOM = SHEET NUMBER TOP = DETAIL NUMBER BOTTOM = SHEET NUMBER TOP = ELEVATION NUMBER BOTTOM = SHEET NUMBER A1 100 REVISION TAG 1 ACCESSORIES TAG A ROOM XXX A NUMBER DENOTES NUMBER OF REVISIONS ELEVATION BENCHMARK LETTER DENOTES PLUMBING FIXTURES & TOILET ROOM ACCESSORIES. SEE A1/A-7 ROOM NUMBER TAG EQUIPMENT TAG Revisions I HEREBY CERTIFY THAT THESE PLANS HAVE BEEN PREPARED IN MY OFFICE AND UNDER MY SUPERVISION AND THAT TO THE BEST OF MY KNOWLEDGE , THE SAME COMPLY WITH ALL LAWS, RULES, REGULATIONS AND ORDINANCES OF _________________________ RELATING TO STRUCTURES AND BUILDINGS. Date Checked By Sheet No. Job No. Drawn By Scale THIS DRAWING HAS BEEN PREPARED FOR INFORMATIONAL AND REFERENCE USE ONLY. ALL ARCHITECTURAL, CIVIL, STRUCTURAL, ELECTRICAL, MECHANICAL AND PLUMBING CODE COMPLIANCE AND ADA ITEMS ARE THE RESPONSIBILITY OF THE ARCHITECT OF RECORD. (REPLACE THIS TEXT WITH ARCHITECT LOGO, ADDRESS & PHONE.) AS NOTED ML C:\Revit Projects\Sloan's - Central_SGuerra.rvt 8/13/2012 3:30:18 PM CS.1 12-4112 Sloan's COVER SHEET PROTOTYPE SMG 08/13/2012 INDEX OF DRAWINGS NO. DESCRIPTION CS.1 COVER SHEET A0.1 GENERAL NOTES A1.1 DIMENSION FLOOR PLAN A1.2 NEW FINISH FLOOR PLAN A2.1 NEW REFLECTED CEILING PLAN A3.1 NEW INTERIOR ELEVATIONS A3.2 NEW INTERIOR, EXTERIOR, & STOREFRONT DETAILS A4.1 MILLWORK ELEVATIONS A5.1 ENLARGED TOILET ROOM PLANS & DETAILS A6.1 DETAILS K1.1 NEW EQUIPMENT PLAN P0.1 NOTES P1.1 FLOOR PLAN P2.1 DETAILS / ISOMETRICS M0.1 NOTES M1.1 MECHANICAL FLOOR AND ROOF PLANS M2.1 DETAILS E001 NOTES, ELECTRICAL SPECIFICATIONS AND SYMBOL LIST E002 ELECTRICAL ONE LINE DIAGRAM AND PANEL SCHEDULE E100 FLOOR PLAN - POWER AND SPECIAL SYSTEMS E200 FLOOR PLAN - LIGHTING FA01 FLOOR PLAN - FIRE ALARM 0 MILLWORK INDEX 1 MILLWORK FLOOR PLAN 2 FRONT/BACK COUNTER 3 SLAT WALL DISPLAY 4 SETTEE SEATING 5 NOT USED 6 DISPLAY PODS 7 OFFICE 8 RESTROOM VANITIES 9 CROWN MOLDING TRUE NORTH SLOAN'S PROTOTYPE COMMERCIAL TENANT REMODEL CORPORATE OWNER: SLOAN'S FRANCHISE LLC 235A WORTH AVE. PALM BEACH, FL 33480 TEL: FAX: ARCHITECT: CHIPMAN DESIGN ARCHITECTURE, INC 2700 S. RIVER ROAD SUITE 400 DES PLAINES, IL 60018 TEL: (847) 298-6900 FAX: (847) 298-6966 GENERAL CONTRACTOR BUILDER: CHARGER CONSTRUCTION & DESIGN, INC. 23 EAST JACKSON BLVD. CHICAGO, IL 60604 CONTACT: TEL: 312-213-4000 FAX: 630-214-0715 YEAR BUILDING CODE APPLICABLE CODES KEY PLAN ABBREVIATIONS BUILDING DATA PROJECT CONTACTS SCALE: NONE RESPONSIBILITY MATRIX SCALE: NONE DRAWING INDEX BUILDING DEPARTMENT CITY BUILDING DEPARTMENT CITY BUILDING DEPARTMENT ADDRESS NUMBER CITY, ZIP PH: ---.---.---- GOVERNMENT AGENCIES HEALTH DEPARTMENT CITY BUILDING DEPARTMENT CITY BUILDING DEPARTMENT ADDRESS NUMBER CITY, ZIP PH: ---.---.---- ZONING: -- USE GROUPS #-#: ASSEMBLY TYPE BUILDING AREA DATA AREA = 2,019 GSF CONSTRUCTION TYPE TYPE ## - DESCRIPTION FIRE PROTECTION ---- OCCUPANTS = ## PERSONS EMPLOYEES = ## PERSONS TOTAL = ## PERSONS ASSEMBLY CLASSIFICATION WATER CLOSETS = # PER ## (MEN AND WOMEN) LAVATORIES = # PER ### (MEN AND WOMEN) DRINKING FOUNTAINS = # PER ### PEOPLE SERVICE SINK = # REQUIRED PLUMBING FIXTURES WATER CLOSETS = # LAVATORIES = # PLUMBING FIXTURE PROVIDED WATER CLOSETS = # LAVATORIES = # PLUMBING FIXTURES CALCULATION OCCUPANCY CALCULATION SITE DATA BUILDING DATA SH SHELF, SHELVING SHNG SHINGLE(S) SHT SHEET SHTH SHEATH(ING) SHU SHUTTER(S) SIDG SIDING SIM SIMILAR SLO SLOPE SNT SEALANT SOL SOLDIER SP SOUNDPROOF SPC SPACE(R) SPEC SPECIFICATION SPK SPEAKER SPL SPECIAL SQ SPECIAL SSK SERVICE SINK ST STAINED GLASS STA STAINLESS STEEL STCO STORM DRAIN STD SQUARE FEET, STOREFRONT STG SEATING STGL SQUARE SUSP SUSPENDED SVYD SERVICE YARD SYD SIDE YARD SYS SYSTEM T TREAD T&G TOUNGE AND GROOVE TBRL TO BE RELOCATED TC TOP OF CURB TEL TELEPHONE TG TEMPERED GLASS THR THRESHOLD TJ TOP OF JOIST TOBR TO BE REMOVED TOR TO REMAIN TP TOP OF PLATE TPD TOILET PAPER DISPENSER TPG TOPPING TPTN TOILET PARTITION TR TRANSOM TSF TOP OF SUB FLOOR TSL TOP OF CONCRETE SLAB TV TELEVISION TYP TYPICAL UNF UNFINISHED UNO UNLESS NOTED OTHERWISE UR URINAL UTL UTILITY VAR VARNISH VB VAPOR BARRIER, VINYL BASE VCT VINYL COMPOSITE TILE VERT VERTICAL VF VINYL FABRIC VIN VINYL VNR VENEER VT VINYL TILE W WEST W/O WITHOUT WC WATER CLOSET WD WOOD WH WALL HUNG WHTR WATER HEATER WI WROUGHT IRON WID WIDTH, WIDE WIN WINDOW WM WIRE MESH WP WATERPROOFING WS WATERSTOP WSCT WAINSCOT WST WEATHER-STRIP, (ING) WWF WELDED WIRE FABRIC PG PLATE GLASS PK PARKING PL PLATE PL PROPERTY LINE PLA PLASTIC PLAM PLASTIC LAMINATE PLAS PLASTER PLF POUNDS PER LINEAR FOOT PLTG PLANTING PNL PANEL(ING) PNT PAINT(ED) PREM PREMOULDED PRF PREFORMED PRPT PARAPET PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT POINT PTD PAPER TOWEL DISPENSER PTN PARTITION PTR PAPER TOWEL RECEPTOR PTR PLANTER PV PAVE(D), (ING) PVC POLYVINYL CHLORIDE PVMT PAVEMENT PWD PLYWOOD QT QUARRY TILE R RISER R&S ROD AND SHELF RA RETURN AIR RAD RADIUS RBL RUBBLE STONE RBT RABBET, REBATE RBT RUBBER TILE RCP ROUND CONCRETE PIPE RD ROOF DRAIN REC RECESS(ED) RECP REINFORCED CONCRETE PIPE REF REFER(ENCE) REFR REFRIGERATOR REG REGISTER REIN REINFORCE, (ED), (ING) REM REMOVE REQ'D REQUIRED RES RESILIENT RET RETURN REV REVISE, REVISION RFG ROOFING RFH ROOF HATCH RFL REFLECT, (ED), (IVE), (OR) RFT RAFTER RH RIGHT HAND RL RAIL(ING) RM ROOM RO ROUGH OPENING ROK ROWLOCK ROW RIGHT OF WAY RTU ROOF TOP UNIT (MECH) RVS REVERSE (SIDE) S SOUTH SCH SCHEDULE SCN SCREEN SCT STORAGE SCUP SCUPPER SEC SECTION SF SPECIFICATION SFGL SAFETY GLASS SFLR STRUCTURAL SG SHEET GLASS SGL SPANDREL GLASS LAV LAVATORY LB LAG BOLT LBL LABEL LGL LAMINATED GLASS LH LEFT HAND LL LIVE LOAD LLD LOOSE LAID LMS LIMESTONE LO LAYOUT LOC LOCATE LPT LOW POINT LT LIGHT LTL LINTEL LVR LOUVER LW LIGHTWEIGHT M MATER(S) MAS MASONRY MAU MAKE-UP AIE UNIT (MECH) MAX MAXIMUM MB MACHINE BOLT MBR MEMBER MC MEDICINE CABINET MDO MEDIUM DENSITY OVERLAY MECH MECHANIC(AL) MED MEDIUM MET METAL MFR MANUFACTURE(R) MGL MIRROR GLASS (FRAMED) MH MANHOLE MIN MINIMUM MIR MIRROR MISC MISCELLANEOUS MLD MOLDING, MOULDING MM MILLIMETER(S) MMB MEMBRANE MOD MODULAR MOV MOVABLE MR MOP RECEPTOR MRB MARBLE MT MOUNT, (ED), (ING) MTL MATERIAL MULL MULLION MW MICROWAVE N NORTH NAT NATURAL NI NICKEL NIC NOT IN CONTRACT NL NAILABLE NO NUMBER NOM NOMINAL NR NOISE REDUCTION NTS NOT TO SCALE OA OVERALL OC ON CENTER(S) OD OUTSIDE DIAMETER OH OVERHEAD OP OPAQUE OPG OPENING OPH OPPOSITE HAND ORN ORNAMENTAL PAR PARALLEL PB PANIC BAR PBD PARTICLE BOARD PCC PRECAST CONCRETE PCF POUNDES PER CUBIC FOOT PCPL PORCELAIN CEMENT PLASTER PD POUND(S) PE PORCELAIN ENAMEL PER PERIMETER PERF PERFORATE(D) PFB PREFABRICATE(D) PFN PREFINISHED FLUR FLUORESCENT FLX FLEXIBLE FN FENCE FND FOUNDATION FOC FACE OF CONCRETE FOF FACE OF FINISH FOM FACE OF MASONRY FOS FACE OF STUDS FP FIREPROOF FPL FIREPLACE FR FRAME(D), (ING) FRT FIRE-RETARDANT FS FULL SIZE FT FIRE TREATED FTG FOOTING FUR FURRED, (ING) FUT FUTURE GA GAGE, GAUGE GB GRAB BAR GC GENERAL CONTRACTOR GCMU GLAZED CONCRETE MASONRY UNIT GD GRADE, GRADING GKT GASKET(ED) GL GLASS, GLAZING GLAM GLUED LAMINATE GRD GUARD GRT GRATE, (ING) GT GROUT GUT GUTTER GV GALVANIZED GVL GRAVEL GWB GYPSUM WALLBOARD GYPL GYPSUM LATH GYPPL GYPSUM PLASTER GYPT GYPSUM TILE HB HOSE BIBB HBD HARDBOARD HC HANDICAP HD HEAVY DUTY HDR HEADER HDW HARDWARE HM HOLLOW METAL HOR HORIZONTAL HPT HIGH POINT HRL HANDRAIL HT HEIGHT HTG HEATING HVAC HEATING/ VENTILATING/ AIR CONDITIONING HWD HARDWOOD ID INSIDE DIAMETER IGL INSULATING GLASS INCAN INCANDESCENT INCIN INCINERATOR INCL INCLUDE, (ED), (ING) INS INSULATE, (ED), (ING) INSC INSULATING CONCRETE INT INTERIOR INTM INTERMEDIATE INV INVERT J JOIST JC JANITOR'S CLOSET JF JOINT FILLER JT JOINT KEC KITCHEN EQUIPMENT CONTRACTOR KIT KITCHEN KO KNOCKOUT KPL KICK PLATE L LENGTH LAB LABORATORY LAD LADDER LAM LAMINATE(D) CPT CARPET CR CHROMIUM CRS COURSE CS COUNTERSINK CSMT CSMT CST CAST STONE CT CERAMIC TILE CTR COUNTER CYD COBIC YARD DEM DEMOLISH, DEMOLITION DF DRINKING FOUNTAIN DIA DIAMETER DIAG DIAGONAL DIM DIMENSION DIV DIVISION DL DEAD LOAD DMT DEMOUNTABLE DN DOWN DP DAMP PROOFING DPR DAMPER DR DOOR DS DOWN SPOUT DSP DISPENSER DT DRAIN TILE DTA DOVETAIL ANCHOR DTL DETAIL DTS DOVETAIL ANCHOR SLOT DW DUMBWAITER DWG DRAWING DWR DRAWER E EAST EA EACH EB EXPANSION BOLT EF EXHAUST FAN (MECH) EJT EXPANSION JOINT EL ELEVATION (VERTICAL HEIGHT) ELAS ELASTIC ELE ELEVATION (VIEW) ELEC ELECTRIC(AL) ELEV ELEVATOR EMER EMERGENCY ENC ENCLOSE, (URE) EP ELECTRIC PANEL EQ EQUAL EQP EQUIPMENT ESC ESCALATOR ESMNT EASEMENT EST ESTIMATE EWC ELECTRIC WATER COOLER EXG EXISTING EXH EXHAUST EXMP EXPANDED METAL PLATE EXT EXTERIOR FA FIRE ALARM FAS FASTEN, FASTENER FBD FIBERBOARD FD FLOW DRAIN FE FIRE EXTIGUISHER FEC FIRE EXTINGUISHER CABINET FFE FINISHED FLOOR ELEVATION FFL FINISHED FLOOR LINE FG FLOAT GLASS FGL FIBERGLASS FHS FIRE HOSE STATION FIN FINISH(ED) FIXT FIXTURE FJT FLUSH JOINT FL FLOW LINE FLG FLASHING FLR FLOOR(ING) A/C AIR CONDITIONING AB ANCHOR BLOT ABV ABOVE AC ACOUSTICAL ACC ACCESS(IBLE) ACFL ACCESS FLOOR ACPL ACOUSTICAL PLASTER ACR ACRYLIC PLASTIC AD AREA DRAIN ADH ADHESIVE ADJ ADJACENT ADJT ADJUSTABLE AFF ABOVE FINISHED FLOOR AGG AGGREGATE AL ALUMINUM ALT ALTERNATE ANC ANCHOR, ANCHORAGE AP ACCESS PANEL ARCH ARCHITECT, ARCHITECTURAL AT ASPHALT TILE AUTO AUTOMATIC AWN AWNING BD BOARD BEL BELOW BET BETWEEN BEY BEYOND BLDG. BUILDING BLK BLOCK BLKG BLOCKING BM BEAM BM BENCHMARK BO BY OWNER BOT BOTTOM BPL BEARING PLATE BRG BEARING BRGL BULLET RESISTANT GLASS BRK BRICK BRKT BRACKET BRZ BRONZE BS BOTH SIDES BUR BUILT UP ROOFING BVL BEVELED CAB CABINET CAN CANVAS CB CATCH BASIN CC COOLER COMPRESSOR (MECH) CEM CEMENT CER CERAMIC CG CORNER GUARD CGL COATED GLASS CHAM CHAMFER CHBD CHALKBOARD CIR CIRCLE CIRC CIRCUMFERENCE CJT CONTROL JOINT CLG CEILING CLR CLEAR, CLEARANCE CLS CLOSURE CM CENTIMETER(S) COL COLUMN COM COMMON COMB COMBINATION COMP COMPRESS, (ED), (ION), (IBLE) COMPO COMPOSITION, COMPOSITE COMPT COMPARTMENT CONN CONNECTION CONST CONSTRUCTION CONT CONTINUE, CONTINUOUS CONTR CONTRACT(OR) CORR CORRUGATED RESPONSIBILITY MATRIX DIVISION FURNISHE D INSTALLED GC KES O GC KES DIVISION 0: CONTRUCTION DOCUMENTS BOND AND INSURANCE PERMIT AND FEES DIVISION 2: SITE CONSTRUCTION GC KES O GC KES DUMPSTER SELECTIVE DEMOLITION FINAL CLEARING DIVISION 3: CONCRETE GC KES O GC KES RAMPS DIVISION 4: MASONRY GC KES O GC KES DIVISION 5: METALS GC KES O GC KES BRACKETS/BASES @ COUNTERS INTERIOR WALL FRAMING DIVISION 6: WOOD, PLASTICS, & COMPOSITES GC KES O GC KES ALL INTERIOR RUNNING TRIM FINISH HARDWARE MILLWORK CABINETS/COUNTERTOPS DIVISION 7: THERMAL & MOISTURE PROTECTION GC KES O GC KES EXTERIOR WALL - EXISTING TO REMAIN DEMISING WALL - EXISTING TO REMAIN DIVISION 8: DOORS & WINDOWS GC KES O GC KES DOORS - INTERIOR & WOOD DOOR HARDWARE STOREFRONT SYSTEMS WINDOW - WOMEN'S TOILET ROOM DIVISION 9: FINISHES GC KES O GC KES TOILET ACCESSORIES TOILET ROOM FINISHES GYPSUM BOARD FINISH ALL OTHER GYP. ASSEMBLIES URETHANE FLOORING CERAMIC FLOOR TILE WALL COVERINGS WALL GLASS TILE DIVISION 10: SPECIALTIES GC KES O GC KES EXTERIOR SIGNAGE INTERIOR TOILET ROOM SIGNAGE INTERIOR SIGNAGE DIVISION 11: EQUIPMENT GC KES O GC KES FOOD SERVICE EQUIPMENT P.O.S. EQUIPMENT SECURITY EQUIPMENT DIVISION 13: SPECIAL CONSTRUCTION GC KES O GC KES VESTIBULE ALTERATION DIVISION 14: CONVEYING EQUIPMENT GC KES O GC KES DIVISION 21: FIRE SUPPRESSION GC KES O GC KES DIVISION 22: PLUMBING GC KES O GC KES PLUMBING DISTRIBUTION PLUMBING FIXTURES DIVISION 23: HEATING, VENTILATION, & AIR CONDITIONING GC KES O GC KES LAVATORY AND WATER CLOSET MECHANICAL DISTRIBUTION DIVISION 26: ELECTRICAL GC KES O GC KES POWER TO SIGNAGE SOUND & P.O.S. SYSTEM SOUND & P.O.S. SYSTEM CONDUIT LIGHT FIXTURES ELECTRICAL RECEPTACLES CONDUIT & PHONE CONDUIT SECURITY SYSTEM 7 FIRE ALARM CONDUIT P.O.S. CABLE FIRE ALARM - PULLS, STROBES, HORNS, ETC. DIVISION 32: EXTERIOR IMPROVEMENTS GC KES O GC KES DIVISION 33: UTILITIES GC KES O GC KES SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SYMBOL LEGEND MECHANICAL / PLUMBING: WCW ENGINEERING 760 CREEL DRIVE WOOD DALE, IL 60191 CONTACT: JOSEPH THOMAS TEL: (630) 595-8800 FAX: (630) 595-8818 ELECTRICAL: DICKERSON ENGINEERING 8101 N. MILWAUKEE NILES, IL 60714 CONTACT: STEVE BERNARD TEL: (847) 966-0290 FAX: (847) 966-0294 FRANCHISOR: SLOAN'S FRANCHISE LLC 235A WORTH AVE. PALM BEACH, FL 33480 TEL: FAX: LANDLORD: SLOAN'S FRANCHISE LLC 235A WORTH AVE. PALM BEACH, FL 33480 TEL: FAX:

J:DWGSloan'sPrototype01 - Drawings02 - s08.13.12 - … · 2015-02-02 · pcpl porcelain cement plaster pd pound(s) pe porcelain enamel per perimeter perf perforate(d) pfb prefabricate(d)

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

ELEVATION TAG

SECTION TAG

NORTH

DETAIL TAG

DOOR TAG

1A-1

1

A-1

1

A-1

NORTH

SHOWS DIRECTION OF MAGNETICNORTH

DENOTES WALL TYPE. SEE 1/ A-5

NUMBER DENOTES DOORREFERENCE TODOOR SCHEDULE. SEE A-1

TOP = SECTION NUMBERBOTTOM = SHEET NUMBER

TOP = DETAIL NUMBERBOTTOM = SHEET NUMBER

TOP = ELEVATION NUMBERBOTTOM = SHEET NUMBER

A1

100

REVISION TAG

1

ACCESSORIES TAG

A

ROOM

XXX

A

NUMBER DENOTES NUMBER OFREVISIONS

ELEVATION BENCHMARK

LETTER DENOTES PLUMBINGFIXTURES & TOILET ROOMACCESSORIES. SEE A1/A-7

ROOM NUMBER TAG

EQUIPMENT TAG

Revisions

I HEREBY CERTIFY THAT THESE PLANSHAVE BEEN PREPARED IN MY OFFICE

AND UNDER MY SUPERVISION ANDTHAT TO THE BEST OF MY

KNOWLEDGE , THE SAME COMPLYWITH ALL LAWS, RULES, REGULATIONS

AND ORDINANCES OF_________________________

RELATING TO STRUCTURES ANDBUILDINGS.

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

THIS

DRA

WIN

G H

AS

BEEN

PRE

PARE

D FO

R IN

FORM

ATI

ON

AL

AN

D RE

FERE

NC

E US

E O

NLY

. A

LL A

RCHI

TEC

TURA

L, C

IVIL

,ST

RUC

TURA

L, E

LEC

TRIC

AL,

MEC

HAN

ICA

L A

ND

PLUM

BIN

GC

ODE

CO

MPL

IAN

CE

AN

D A

DA IT

EMS

ARE

THE

RESP

ON

SIBI

LITY

OF

THE

ARC

HITE

CT

OF

REC

ORD

. (R

EPLA

CE

THIS

TEX

T W

ITH

ARC

HITE

CT

LOG

O, A

DDRE

SS &

PHO

NE.

)

AS NOTED

ML

C:\R

evit

Pro

ject

s\S

loan

's -

Cen

tral

_SG

uerr

a.rv

t8/

13/2

012

3:30

:18

PM

CS.1

12-4112

Slo

an's

CO

VE

R S

HE

ET

PR

OT

OT

YP

E

SMG

08/13/2012

INDEX OF DRAWINGSNO. DESCRIPTION

CS.1 COVER SHEET

A0.1 GENERAL NOTESA1.1 DIMENSION FLOOR PLANA1.2 NEW FINISH FLOOR PLANA2.1 NEW REFLECTED CEILING PLANA3.1 NEW INTERIOR ELEVATIONSA3.2 NEW INTERIOR, EXTERIOR, & STOREFRONT DETAILSA4.1 MILLWORK ELEVATIONSA5.1 ENLARGED TOILET ROOM PLANS & DETAILSA6.1 DETAILS

K1.1 NEW EQUIPMENT PLAN

P0.1 NOTESP1.1 FLOOR PLANP2.1 DETAILS / ISOMETRICS

M0.1 NOTESM1.1 MECHANICAL FLOOR AND ROOF PLANSM2.1 DETAILS

E001 NOTES, ELECTRICAL SPECIFICATIONS AND SYMBOL LISTE002 ELECTRICAL ONE LINE DIAGRAM AND PANEL SCHEDULEE100 FLOOR PLAN - POWER AND SPECIAL SYSTEMSE200 FLOOR PLAN - LIGHTING

FA01 FLOOR PLAN - FIRE ALARM

0 MILLWORK INDEX1 MILLWORK FLOOR PLAN2 FRONT/BACK COUNTER3 SLAT WALL DISPLAY4 SETTEE SEATING5 NOT USED6 DISPLAY PODS7 OFFICE8 RESTROOM VANITIES9 CROWN MOLDING

TRUENORTH

SLOAN'SPROTOTYPE

COMMERCIAL TENANT REMODEL

CORPORATE OWNER:SLOAN'S FRANCHISE LLC235A WORTH AVE.PALM BEACH, FL 33480TEL:FAX:

ARCHITECT:CHIPMAN DESIGN ARCHITECTURE, INC2700 S. RIVER ROADSUITE 400DES PLAINES, IL 60018TEL: (847) 298-6900FAX: (847) 298-6966

GENERAL CONTRACTOR BUILDER:CHARGER CONSTRUCTION & DESIGN, INC.23 EAST JACKSON BLVD.CHICAGO, IL 60604CONTACT:TEL: 312-213-4000FAX: 630-214-0715

YEAR BUILDING CODE

APPLICABLE CODES

KEY PLAN

ABBREVIATIONS

BUILDING DATA PROJECT CONTACTSSCALE: NONE

RESPONSIBILITY MATRIXSCALE: NONE

DRAWING INDEX

BUILDING DEPARTMENTCITY BUILDING DEPARTMENTCITY BUILDING DEPARTMENTADDRESS NUMBERCITY, ZIPPH: ---.---.----

GOVERNMENT AGENCIES

HEALTH DEPARTMENTCITY BUILDING DEPARTMENTCITY BUILDING DEPARTMENTADDRESS NUMBERCITY, ZIPPH: ---.---.----

ZONING: --

USE GROUPS#-#: ASSEMBLY TYPE

BUILDING AREA DATAAREA = 2,019 GSF

CONSTRUCTION TYPETYPE ## - DESCRIPTION

FIRE PROTECTION----

OCCUPANTS = ## PERSONSEMPLOYEES = ## PERSONSTOTAL = ## PERSONS

ASSEMBLY CLASSIFICATIONWATER CLOSETS = # PER ## (MEN AND WOMEN)LAVATORIES = # PER ### (MEN AND WOMEN)DRINKING FOUNTAINS = # PER ### PEOPLESERVICE SINK = #

REQUIRED PLUMBING FIXTURESWATER CLOSETS = #LAVATORIES = #

PLUMBING FIXTURE PROVIDEDWATER CLOSETS = #LAVATORIES = #

PLUMBING FIXTURES CALCULATION

OCCUPANCY CALCULATION

SITE DATA

BUILDING DATA

SH SHELF, SHELVINGSHNG SHINGLE(S)SHT SHEETSHTH SHEATH(ING)SHU SHUTTER(S)SIDG SIDINGSIM SIMILARSLO SLOPESNT SEALANTSOL SOLDIERSP SOUNDPROOFSPC SPACE(R)SPEC SPECIFICATIONSPK SPEAKERSPL SPECIALSQ SPECIALSSK SERVICE SINKST STAINED GLASSSTA STAINLESS STEELSTCO STORM DRAINSTD SQUARE FEET,

STOREFRONT

STG SEATINGSTGL SQUARESUSP SUSPENDEDSVYD SERVICE YARDSYD SIDE YARDSYS SYSTEMT TREADT&G TOUNGE AND GROOVETBRL TO BE RELOCATEDTC TOP OF CURBTEL TELEPHONETG TEMPERED GLASSTHR THRESHOLDTJ TOP OF JOISTTOBR TO BE REMOVEDTOR TO REMAINTP TOP OF PLATETPD TOILET PAPER

DISPENSER

TPG TOPPINGTPTN TOILET PARTITIONTR TRANSOMTSF TOP OF SUB FLOORTSL TOP OF CONCRETE

SLAB

TV TELEVISIONTYP TYPICALUNF UNFINISHEDUNO UNLESS NOTED

OTHERWISE

UR URINALUTL UTILITYVAR VARNISHVB VAPOR BARRIER,

VINYL BASE

VCT VINYL COMPOSITE TILEVERT VERTICALVF VINYL FABRICVIN VINYLVNR VENEERVT VINYL TILEW WESTW/O WITHOUTWC WATER CLOSETWD WOODWH WALL HUNGWHTR WATER HEATERWI WROUGHT IRONWID WIDTH, WIDEWIN WINDOWWM WIRE MESHWP WATERPROOFINGWS WATERSTOPWSCT WAINSCOTWST WEATHER-STRIP, (ING)WWF WELDED WIRE FABRIC

PG PLATE GLASSPK PARKINGPL PLATEPL PROPERTY LINEPLA PLASTICPLAM PLASTIC LAMINATEPLAS PLASTERPLF POUNDS PER LINEAR

FOOT

PLTG PLANTINGPNL PANEL(ING)PNT PAINT(ED)PREM PREMOULDEDPRF PREFORMEDPRPT PARAPETPSF POUNDS PER SQUARE

FOOT

PSI POUNDS PER SQUAREINCH

PT POINTPTD PAPER TOWEL

DISPENSER

PTN PARTITIONPTR PAPER TOWEL

RECEPTOR

PTR PLANTERPV PAVE(D), (ING)PVC POLYVINYL CHLORIDEPVMT PAVEMENTPWD PLYWOODQT QUARRY TILER RISERR&S ROD AND SHELFRA RETURN AIRRAD RADIUSRBL RUBBLE STONERBT RABBET, REBATERBT RUBBER TILERCP ROUND CONCRETE

PIPE

RD ROOF DRAINREC RECESS(ED)RECP REINFORCED

CONCRETE PIPE

REF REFER(ENCE)REFR REFRIGERATORREG REGISTERREIN REINFORCE, (ED), (ING)REM REMOVEREQ'D REQUIREDRES RESILIENTRET RETURNREV REVISE, REVISIONRFG ROOFINGRFH ROOF HATCHRFL REFLECT, (ED), (IVE),

(OR)

RFT RAFTERRH RIGHT HANDRL RAIL(ING)RM ROOMRO ROUGH OPENINGROK ROWLOCKROW RIGHT OF WAYRTU ROOF TOP UNIT

(MECH)

RVS REVERSE (SIDE)S SOUTHSCH SCHEDULESCN SCREENSCT STORAGESCUP SCUPPERSEC SECTIONSF SPECIFICATIONSFGL SAFETY GLASSSFLR STRUCTURALSG SHEET GLASSSGL SPANDREL GLASS

LAV LAVATORYLB LAG BOLTLBL LABELLGL LAMINATED GLASSLH LEFT HANDLL LIVE LOADLLD LOOSE LAIDLMS LIMESTONELO LAYOUTLOC LOCATELPT LOW POINTLT LIGHTLTL LINTELLVR LOUVERLW LIGHTWEIGHTM MATER(S)MAS MASONRYMAU MAKE-UP AIE UNIT

(MECH)

MAX MAXIMUMMB MACHINE BOLTMBR MEMBERMC MEDICINE CABINETMDO MEDIUM DENSITY

OVERLAY

MECH MECHANIC(AL)MED MEDIUMMET METALMFR MANUFACTURE(R)MGL MIRROR GLASS

(FRAMED)

MH MANHOLEMIN MINIMUMMIR MIRRORMISC MISCELLANEOUSMLD MOLDING, MOULDINGMM MILLIMETER(S)MMB MEMBRANEMOD MODULARMOV MOVABLEMR MOP RECEPTORMRB MARBLEMT MOUNT, (ED), (ING)MTL MATERIALMULL MULLIONMW MICROWAVEN NORTHNAT NATURALNI NICKELNIC NOT IN CONTRACTNL NAILABLENO NUMBERNOM NOMINALNR NOISE REDUCTIONNTS NOT TO SCALEOA OVERALLOC ON CENTER(S)OD OUTSIDE DIAMETEROH OVERHEADOP OPAQUEOPG OPENINGOPH OPPOSITE HANDORN ORNAMENTALPAR PARALLELPB PANIC BARPBD PARTICLE BOARDPCC PRECAST CONCRETEPCF POUNDES PER CUBIC

FOOT

PCPL PORCELAIN CEMENTPLASTER

PD POUND(S)PE PORCELAIN ENAMELPER PERIMETERPERF PERFORATE(D)PFB PREFABRICATE(D)PFN PREFINISHED

FLUR FLUORESCENTFLX FLEXIBLEFN FENCEFND FOUNDATIONFOC FACE OF CONCRETEFOF FACE OF FINISHFOM FACE OF MASONRYFOS FACE OF STUDSFP FIREPROOFFPL FIREPLACEFR FRAME(D), (ING)FRT FIRE-RETARDANTFS FULL SIZEFT FIRE TREATEDFTG FOOTINGFUR FURRED, (ING)FUT FUTUREGA GAGE, GAUGEGB GRAB BARGC GENERAL

CONTRACTOR

GCMU GLAZED CONCRETEMASONRY UNIT

GD GRADE, GRADINGGKT GASKET(ED)GL GLASS, GLAZINGGLAM GLUED LAMINATEGRD GUARDGRT GRATE, (ING)GT GROUTGUT GUTTERGV GALVANIZEDGVL GRAVELGWB GYPSUM WALLBOARDGYPL GYPSUM LATHGYPPL GYPSUM PLASTERGYPT GYPSUM TILEHB HOSE BIBBHBD HARDBOARDHC HANDICAPHD HEAVY DUTYHDR HEADERHDW HARDWAREHM HOLLOW METALHOR HORIZONTALHPT HIGH POINTHRL HANDRAILHT HEIGHTHTG HEATINGHVAC HEATING/

VENTILATING/ AIRCONDITIONING

HWD HARDWOODID INSIDE DIAMETERIGL INSULATING GLASSINCAN INCANDESCENTINCIN INCINERATORINCL INCLUDE, (ED), (ING)INS INSULATE, (ED), (ING)INSC INSULATING

CONCRETE

INT INTERIORINTM INTERMEDIATEINV INVERTJ JOISTJC JANITOR'S CLOSETJF JOINT FILLERJT JOINTKEC KITCHEN EQUIPMENT

CONTRACTOR

KIT KITCHENKO KNOCKOUTKPL KICK PLATEL LENGTHLAB LABORATORYLAD LADDERLAM LAMINATE(D)

CPT CARPETCR CHROMIUMCRS COURSECS COUNTERSINKCSMT CSMTCST CAST STONECT CERAMIC TILECTR COUNTERCYD COBIC YARDDEM DEMOLISH,

DEMOLITION

DF DRINKING FOUNTAINDIA DIAMETERDIAG DIAGONALDIM DIMENSIONDIV DIVISIONDL DEAD LOADDMT DEMOUNTABLEDN DOWNDP DAMP PROOFINGDPR DAMPERDR DOORDS DOWN SPOUTDSP DISPENSERDT DRAIN TILEDTA DOVETAIL ANCHORDTL DETAILDTS DOVETAIL ANCHOR

SLOT

DW DUMBWAITERDWG DRAWINGDWR DRAWERE EASTEA EACHEB EXPANSION BOLTEF EXHAUST FAN (MECH)EJT EXPANSION JOINTEL ELEVATION (VERTICAL

HEIGHT)

ELAS ELASTICELE ELEVATION (VIEW)ELEC ELECTRIC(AL)ELEV ELEVATOREMER EMERGENCYENC ENCLOSE, (URE)EP ELECTRIC PANELEQ EQUALEQP EQUIPMENTESC ESCALATORESMNT EASEMENTEST ESTIMATEEWC ELECTRIC WATER

COOLER

EXG EXISTINGEXH EXHAUSTEXMP EXPANDED METAL

PLATE

EXT EXTERIORFA FIRE ALARMFAS FASTEN, FASTENERFBD FIBERBOARDFD FLOW DRAINFE FIRE EXTIGUISHERFEC FIRE EXTINGUISHER

CABINET

FFE FINISHED FLOORELEVATION

FFL FINISHED FLOOR LINEFG FLOAT GLASSFGL FIBERGLASSFHS FIRE HOSE STATIONFIN FINISH(ED)FIXT FIXTUREFJT FLUSH JOINTFL FLOW LINEFLG FLASHINGFLR FLOOR(ING)

A/C AIR CONDITIONINGAB ANCHOR BLOTABV ABOVEAC ACOUSTICALACC ACCESS(IBLE)ACFL ACCESS FLOORACPL ACOUSTICAL PLASTERACR ACRYLIC PLASTICAD AREA DRAINADH ADHESIVEADJ ADJACENTADJT ADJUSTABLEAFF ABOVE FINISHED

FLOOR

AGG AGGREGATEAL ALUMINUMALT ALTERNATEANC ANCHOR, ANCHORAGEAP ACCESS PANELARCH ARCHITECT,

ARCHITECTURAL

AT ASPHALT TILEAUTO AUTOMATICAWN AWNINGBD BOARDBEL BELOWBET BETWEENBEY BEYONDBLDG. BUILDINGBLK BLOCKBLKG BLOCKINGBM BEAMBM BENCHMARKBO BY OWNERBOT BOTTOMBPL BEARING PLATEBRG BEARINGBRGL BULLET RESISTANT

GLASS

BRK BRICKBRKT BRACKETBRZ BRONZEBS BOTH SIDESBUR BUILT UP ROOFINGBVL BEVELEDCAB CABINETCAN CANVASCB CATCH BASINCC COOLER

COMPRESSOR (MECH)

CEM CEMENTCER CERAMICCG CORNER GUARDCGL COATED GLASSCHAM CHAMFERCHBD CHALKBOARDCIR CIRCLECIRC CIRCUMFERENCECJT CONTROL JOINTCLG CEILINGCLR CLEAR, CLEARANCECLS CLOSURECM CENTIMETER(S)COL COLUMNCOM COMMONCOMB COMBINATIONCOMP COMPRESS, (ED),

(ION), (IBLE)

COMPO COMPOSITION,COMPOSITE

COMPT COMPARTMENTCONN CONNECTIONCONST CONSTRUCTIONCONT CONTINUE,

CONTINUOUS

CONTR CONTRACT(OR)CORR CORRUGATED

RESPONSIBILITY MATRIX

DIVISION

FURNISHED INSTALLED

GC KES O GC KES

DIVISION 0: CONTRUCTION DOCUMENTSBOND AND INSURANCEPERMIT AND FEES

DIVISION 2: SITE CONSTRUCTION GC KES O GC KESDUMPSTERSELECTIVE DEMOLITIONFINAL CLEARING

DIVISION 3: CONCRETE GC KES O GC KESRAMPS

DIVISION 4: MASONRY GC KES O GC KES

DIVISION 5: METALS GC KES O GC KESBRACKETS/BASES @ COUNTERSINTERIOR WALL FRAMING

DIVISION 6: WOOD, PLASTICS, &COMPOSITES

GC KES O GC KES

ALL INTERIOR RUNNING TRIMFINISH HARDWAREMILLWORK CABINETS/COUNTERTOPS

DIVISION 7: THERMAL & MOISTUREPROTECTION

GC KES O GC KES

EXTERIOR WALL - EXISTING TO REMAINDEMISING WALL - EXISTING TO REMAIN

DIVISION 8: DOORS & WINDOWS GC KES O GC KESDOORS - INTERIOR & WOODDOOR HARDWARESTOREFRONT SYSTEMSWINDOW - WOMEN'S TOILET ROOM

DIVISION 9: FINISHES GC KES O GC KESTOILET ACCESSORIESTOILET ROOM FINISHESGYPSUM BOARD FINISHALL OTHER GYP. ASSEMBLIESURETHANE FLOORINGCERAMIC FLOOR TILEWALL COVERINGSWALL GLASS TILE

DIVISION 10: SPECIALTIES GC KES O GC KESEXTERIOR SIGNAGEINTERIOR TOILET ROOM SIGNAGEINTERIOR SIGNAGE

DIVISION 11: EQUIPMENT GC KES O GC KESFOOD SERVICE EQUIPMENTP.O.S. EQUIPMENTSECURITY EQUIPMENT

DIVISION 13: SPECIAL CONSTRUCTION GC KES O GC KESVESTIBULE ALTERATION

DIVISION 14: CONVEYING EQUIPMENT GC KES O GC KES

DIVISION 21: FIRE SUPPRESSION GC KES O GC KES

DIVISION 22: PLUMBING GC KES O GC KESPLUMBING DISTRIBUTIONPLUMBING FIXTURES

DIVISION 23: HEATING, VENTILATION, & AIRCONDITIONING

GC KES O GC KES

LAVATORY AND WATER CLOSETMECHANICAL DISTRIBUTION

DIVISION 26: ELECTRICAL GC KES O GC KESPOWER TO SIGNAGESOUND & P.O.S. SYSTEMSOUND & P.O.S. SYSTEM CONDUITLIGHT FIXTURESELECTRICAL RECEPTACLESCONDUIT & PHONE CONDUITSECURITY SYSTEM 7 FIRE ALARM CONDUITP.O.S. CABLEFIRE ALARM - PULLS, STROBES, HORNS,ETC.

DIVISION 32: EXTERIOR IMPROVEMENTS GC KES O GC KES

DIVISION 33: UTILITIES GC KES O GC KES

SCALE: NONESCALE: NONE

SCALE: NONE

SCALE: NONE

SCALE: NONE

SYMBOL LEGEND

MECHANICAL / PLUMBING:WCW ENGINEERING760 CREEL DRIVEWOOD DALE, IL 60191CONTACT: JOSEPH THOMASTEL: (630) 595-8800FAX: (630) 595-8818

ELECTRICAL:DICKERSON ENGINEERING8101 N. MILWAUKEENILES, IL 60714CONTACT: STEVE BERNARDTEL: (847) 966-0290FAX: (847) 966-0294

FRANCHISOR:SLOAN'S FRANCHISE LLC235A WORTH AVE.PALM BEACH, FL 33480TEL:FAX:

LANDLORD:SLOAN'S FRANCHISE LLC235A WORTH AVE.PALM BEACH, FL 33480TEL:FAX:

32"

36"

24"

MA

X. D

IST

AN

CE

FO

R M

IN. C

LEA

RA

NC

E

FIG. 1

36" MIN.12 1/16" MIN. 12" MIN.

60"

MIN

.

36 1

/16"

MIN

.

60"

60"

FIG. 3A

FIG. 3B

FIG. 32

17" MIN.

19" MAX.

48" MIN.

30"

MIN

.

FIG. 29A FIG. 29B

38 1

1/16

"

12" MIN.12" MIN.

35 15/16" MIN.

35 15/16" MIN.

12" 41 15/16" MIN.

17"

-19"

32 1

5/16

" -3

6"

19 1

/16"

MIN

.

53 15/16" MIN.

NOTE:X=12 IN. (305 mm) IF DOORHAS BOTH A CLOSER AND LATCH

(A) FRONT APPROACHES - SWINGING DOORS

NOTE: X=36 IN. (915 mm) MINIMUM IF Y = 60 IN.(1525 mm); X = 42 IN. (1065 mm) MINIMUM IF Y = 54IN. (1370 mm).

NOTE:Y = 48 IN. (1220 mm) MINIMUM IFDOOR HAS BOTH A LATCH AND CLOSER

(B) HINGE SIDE APPROACHES - SWINGING DOORS

NOTE:Y = 54 IN. (1370 mm) MINIMUM IFDOOR HAS CLOSER

NOTE:Y = 48 IN. (1220 mm) MINIMUM IFDOOR HAS CLOSER

(C) LATCH SIDE APPROACHES - SWINGING DOORS NOTE: ALL DOORS INALCOVES SHALL COMPLY WITH THE CLEARANCES FOR FRONT APPROACHES

FIG. 25

60 1

/16"

17 15/16" MIN, 24" PREFERRED

FULL SIDE

48 1

/16"

X PUSH SIDE

Y

X

FULL SIDE

FULL SIDE

45 7

/16"

23 3/16"23 15/16"

42 1

/16"

Y

54 1/16"

PUSH SIDE

PUSH SIDE

47 15/16"

Z

X

48"

30 1

/16"

29 1

5/16

"

47 15/16"

14 1

5/16

" M

IN.48

"

Z

47 15/16"

Y

X

FIG. 5

(A) HIGH FORWARD REACH LIMIT

(B) MAXIMUM FORWARD REACHOVER AN OBSTRUCTION

NOTE: X SHALL BE 25 IN. (635 mm);Z SHALL BE X. WHEN X 20 IN. (510mm), THEN Y SHALL BE 48 IN. (1220 mm) MAXIMUM. WHEN X IS 20 TO25 IN. (510 to 635 mm), THEN Y SHALL BE 44 IN. (1120 mm) MAXIMUM

31 15/16"

FIG. 24B FIG. 24C

31 15/16"

FIG. 24A

31 15/16"

10 1/16" 29 15/16"

48"

(A) CLEAR FLOOR SPACEPARALLEL APPROACH

(B) HIGH AND LOWSIDE REACH LIMITS

(C) MAXIMUM SIDE REACHOVER OBSTRUCTION

34 1

/16"

MA

X.

46 1

/16"

30 1/16" 23 15/16"

53 1

5/16

"

10" 30"

8 15

/16"

FIG. 6

Revisions

I HEREBY CERTIFY THAT THESE PLANSHAVE BEEN PREPARED IN MY OFFICE

AND UNDER MY SUPERVISION ANDTHAT TO THE BEST OF MY

KNOWLEDGE , THE SAME COMPLYWITH ALL LAWS, RULES, REGULATIONS

AND ORDINANCES OF_________________________

RELATING TO STRUCTURES ANDBUILDINGS.

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

THIS

DRA

WIN

G H

AS

BEEN

PRE

PARE

D FO

R IN

FORM

ATI

ON

AL

AN

D RE

FERE

NC

E US

E O

NLY

. A

LL A

RCHI

TEC

TURA

L, C

IVIL

,ST

RUC

TURA

L, E

LEC

TRIC

AL,

MEC

HAN

ICA

L A

ND

PLUM

BIN

GC

ODE

CO

MPL

IAN

CE

AN

D A

DA IT

EMS

ARE

THE

RESP

ON

SIBI

LITY

OF

THE

ARC

HITE

CT

OF

REC

ORD

. (R

EPLA

CE

THIS

TEX

T W

ITH

ARC

HITE

CT

LOG

O, A

DDRE

SS &

PHO

NE.

)

AS NOTED

ML

C:\R

evit

Pro

ject

s\S

loan

's -

Cen

tral

_SG

uerr

a.rv

t8/

13/2

012

3:29

:58

PM

A0.1

12-4112

Slo

an's

GE

NE

RA

L N

OT

ES

PR

OT

OT

YP

E

MAP

08/13/2012

ADA NOTES

1. ALL CONTROLS AND OPERABLE PARTS MUST HAVE A HEIGHT OF 15" TO 48"ABOVE FLOOR.

2. PROVIDE SIGNAGE AT TOILET ROOMS. SIGNAGE SHALL DESIGNATE MEN'SAND WOMEN'S TOILET AND HAVE BRAILLE. MOUNTING HEIGHT SHALL BE 60"ABOVE FINISH FLOOR TO CENTER OF SIGN.

3. PROVIDE INSULATION AT EXPOSED PIPES BELOW TOILET ROOM SINKS.4. STORAGE UNITS SHALL HAVE A MAXIMUM HEIGHT OF 48" TO THE TOP OF

BOTTOM SHELF.

NEW GENERAL NOTES

1. THESE DRAWINGS REFLECT XXXXXXXXX STANDARDS AS OF XXXXXXXX.2. ALL ITEMS SHOWN ARE NEW TO BE PROVIDED & INSTALLED BY G.C.

UNLESS NOTED OTHERWISE.3. DO NOT SCALE DRAWINGS- WRITTEN DIMENSIONS TAKE PRECEDENT.4. CONTRACTOR TO FIELD VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS

PRIOR TO BID.5. IN CASE OF DISCREPANCIES OR CONFLICTS, NOTIFY ARCHITECT BEFORE

PROCEEDING WITH ANY WORK.6. THESE DOCUMENTS HAVE BEEN PREPARED EXPRESSLY FOR USE BY

SLOAN'S. SOLELY FOR THE PURPOSE OF TENANT IMPROVEMENTS WITHINAN EXISTING BUILDING PROVIDED BY A BUILDING OWNER. (AT THE SPECIFICLOCATION MENTIONED)

7. ANY ADDITIONAL USE OF THESE DOCUMENTS FOR ANY REASON OTHERTHAN THAT MENTIONED ABOVE MUST BE AUTHORIZED IN WRITING BYCHIPMAN DESIGN ARCHITECTS (THE COPYRIGHT HOLDER).

8. SIGNAGE AS SHOWN IN THESE DRAWINGS IS SCHEMATIC ONLY FORILLUSTRATION PURPOSES AND DOES NOT IMPLY OR DESCRIBE ANYMEANS, METHODS, OR DETAILS PERTAINING TO INSTALLATION OF THEAWNING OR SIGNAGE. IT SHALL BE SOLELY THE SIGN CONTRACTOR'SRESPONSIBILITY TO DESIGN, FABRICATE, AND INSTALL THE SIGN UNDERSEPARATE PERMIT. ANY AND ALL STRUCTURAL CONSIDERATIONS SHALLBE COORDINATED BETWEEN THE SIGNAGE CONTRACTOR, THE BUILDINGOWNER, AND HIS DESIGN PROFESSIONALS. THE AWNING/SIGNCONTRACTOR SHALL SUBMIT SHOP DRAWINGS DESCRIBING THEAWNING/SIGNAGE DESIGN INCLUDING FINISHES, COLORS, AND DESIGNDIMENSIONS TO THE OWNER FOR DESIGN INTENT REVIEW ONLY PRIOR TOAWNING/SIGN FABRICATION.

9. THESE DRAWINGS AS LISTED IN THE DRAWING INDEX ALONG WITH THESPECIFICATION & CONTRACT FOR CONSTRUCTION CONSTITUTE THEINSTRUMENTS OF SERVICE AND ARE CONSIDERED A SINGLE ENTITY. THECONTRACTOR IS THEREFOR BOUND BY ALL INFORMATION INCLUDED.

10. ONLY DRAWINGS MARKED "ISSUED FOR CONSTRUCTION" BY CHIPMANDESIGN SHALL BE USED AS A BASIS FOR CONSTRUCTION.

11. CONTACT BUILDING OWNER FOR COORDINATION OF STAGING AND REFUSEREMOVAL PRIOR TO SIGNING THE CONTRACT FOR CONSTRUCTION. ANYADJUSTMENT IN THE CONTRACT AMOUNT OR DURATION DUE TO LANDLORD.REQUIREMENTS SHALL BE MADE PRIOR TO CONTRACT EXECUTION.

12. ALL FLOOR SLAB CUTTING , TRENCHING AND REMOVAL SHALL BEREPLACED WITH THE SAME MATERIAL IN THE SAME THICKNESS OF THEADJACENT FLOOR MATERIAL. ADDITIONAL, CONC. PATCHING SHALL BEDOWELED INTO THE ADJACENT CONCRETE SLAB TO MINIMIZEDIFFERENTIAL SETTLEMENT OF THE FLOOR SYSTEM.

13. ANY REQUIRED ROOF PENETRATIONS ARE TO BE PERFORMED BYBUILDING OWNER'S ROOFING CONTRACTOR. CONTACT BUILDING OWNERTO COORDINATE.

14. PROVIDE LANDLORD SPRINKLER SHOP DRAWINGS AND HYDROSTATICCALCULATIONS FOR APPROVAL PRIOR TO WORK IF REQUIRED.

15. PROVIDE TEMPORARY BRACING AND SHORING WITH CONNECTIONS OFSUFFICIENT STRENGTH TO BEAR IMPOSED LOADS, AND TO PROTECT ALLPERSONS AND PROPERTY, AND TO ENSURE PROPER ALIGNMENT.COMPLY WITH ALL STATE, O.S.H.A. AND LOCAL CODES. THE CONTRACTORSHALL ASSUME RESPONSIBILITY FOR PROVIDING ADEQUATE BRACING OFWALLS DURING DEMOLITION AND ERECTION TO PREVENT DAMAGE DUE TOLATERAL LOADS AND CONSTRUCTION IMPACTS. CONTRACTOR SHALLASSUME ALL RESPONSIBILITY FOR DAMAGE DUE TO HIS FAILURE TO TAKESUCH PRECAUTIONS.

16. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS IN FIELD PRIOR TODEMOLITION & NOTIFY THIS OFFICE IN CASE OF DISCREPANCIES BEFOREPROCEEDING.

17. BY THE ACT OF SUBMITTING A BID, THE CONTRACTOR WILL BE DEEMED TOHAVE COMPLIED WITH THE FOREGOING TO HAVE ACCEPTED SUCHCONDITIONS AND TO HAVE MADE ALLOWANCES THEREFORE IN PREPARINGHIS BID.

18. DEMOLISHED MATERIALS SHALL BECOME THE GENERAL CONTRACTOR'SPROPERTY AND SHALL BE REMOVED FROM THE SITE WITH FURTHERDISPOSITION AT THE GENERAL CONTRACTOR'S OPTION, EXCEPT FOR ITEMSOR MATERIAL INDICATED TO BE RE-USED, SALVAGED, REINSTALLED, OROTHERWISE INDICATED TO REMAIN THE OWNER'S PROPERTY.

19. SURVEY THE CONDITION OF THE BUILDING TO DETERMINE WHETHERREMOVING ANY ELEMENT MIGHT RESULT IN STRUCTURAL DEFICIENCY ORUNPLANNED COLLAPSE OF ANY PORTION OF THE STRUCTURE ORADJACENT STRUCTURES DURING SELECTIVE DEMOLITION.

20. MAINTAIN EXISTING UTILITIES WHERE APPLICABLE TO REMAIN IN SERVICEAND PROTECT THEM AGAINST DAMAGE DURING SELECTIVE DEMOLITIONOPERATIONS.

21. CONDUCT DEMOLITION OPERATIONS AND REMOVE DEBRIS TO ENSUREMINIMAL INTERFERENCE WITH ROADS, STREETS, WALKS, AND OTHERADJACENT OCCUPIED AND USED FACILITIES. REMOVE & TRANSPORTDEBRIS IN A MANNER THAT WILL PREVENT SPILLAGE ON ADJACENTSURFACES AND AREAS. PROMPTLY DISPOSE OF DEMOLISHEDMATERIALS. DO NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE ONSITE. TRANSPORT DEMOLISHED MATERIALS OFF OWNER'S PROPERTY ANDLEGALLY DISPOSE OF THEM.

22. PROTECT WALLS, ROOF, AND EXISTING FINISH WORK THAT ARE TO REMAINAND ARE EXPOSED DURING DEMOLITION OPERATIONS.

23. ALL WORK SHALL BE IN COMPLIANCE WITH APPLICABLE FEDERAL, STATEAND LOCAL BUILDING CODES, REGULATIONS, ORDINANCES ANDSTANDARDS INCLUDING ADA AND OR OTHER HANDICAP ACCESSIBILITYCODES.

24. GEN. CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDINGSCHEDULING AND SEQUENCING OF THE WORK.

25. THE CONSTRUCTION NOTES AND DRAWINGS ARE SUPPLIED TO ILLUSTRATETHE DESIGN AND GENERAL TYPE OF CONSTRUCTION DESIRED AND AREINTENDED TO IMPLY THE FINEST QUALITY OF CONSTRUCTION, MATERIALAND WORKMANSHIP THROUGHOUT.

26. THE DRAWINGS ARE NOT TO BE SCALED. FOR INFORMATION CONCERNINGEXISTING CONDITIONS, ETC., VERIFICATION MUST BE DONE IN THE FIELD.LARGE SCALE DRAWINGS HAVE PRECEDENCE OVER SMALL SCALEDRAWINGS.

27. PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION, CONTRACTOR SHALLVERIFY EXISTENCE AND LOCATION OF ALL EXISTING ABOVE AND BELOWGRADE, UTILITIES, INCLUDING SANITARY SEWER, STORM SEWER, WATER,GAS, ELECTRICAL, TELEPHONE, ETC. ANY DISCREPANCIES IN UTILITYLOCATIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THEOWNER'S REPRESENTATIVE.

28. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OFALL BUILDING DIMENSIONS PRIOR TO BEGINNING CONSTRUCTION ANDSHALL IMMEDIATELY NOTIFY OWNER'S REPRESENTATIVE OF ANYVARIANCE OR DISCREPANCY AFFECTING NEW CONSTRUCTION PRIOR TOPROCEEDING WITH WORK.

29. CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING IN WALLS FORSUPPORT OF ALL EQUIPMENT, SHELVING, ACCESSORIES AND OTHERDEVICES REQUIRED.

30. ALL PENETRATIONS SHALL RECEIVE CAULKING TO SEAL ANY TYPE OFENERGY LOSS.

31. THE CONTRACTOR SHALL VERIFY AND COORDINATE ALL APPLICABLEDIMENSIONS OF FIXTURES AND EQUIPMENT SUPPLIED AND/OR INSTALLEDBY OTHERS.

32. UPON COMPLETION OF PROJECT, OBTAIN ALL FINAL INSPECTIONS ASREQUIRED BY LOCAL JURISDICTIONS AND FURNISH OWNER WITH EVIDENCEOF ALL SUCH INSPECTIONS AND CERTIFICATES OF OCCUPANCY.

33. ALL MEANS OF EGRESS AND FIRE PROTECTION SHALL BE MAINTAINED ATALL TIMES AND ANY SHUT DOWN OF LIFE SAFETY OR BUILDING SYSTEMSSHALL BE APPROVED AND COORDINATED IN ADVANCE WITH THE OWNERAND LOCAL BUILDING DEPARTMENT.

34. SIGNS ARE PROVIDED BY SIGN CONTRACTOR. GENERAL CONTRACTORSHALL COORDINATE REQUIREMENTS FOR MOUNTING & POWER.

35. ALL HANDSINK LOCATIONS SHALL HAVE CEMENT BOARD BACKING 48" INHEIGHT AFF.

36. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SETUP ANDCOORDINATION OF ALL THE UTILITY SERVICES FOR THE PROJECT.

37. MAXIMUM OCCUPANCY SIGN TO BE POSTED PER LOCAL CODE. SIGNFURNISHED AND INSTALLED BY GENERAL CONTRACTOR.

3/8" = 1'-0"1 ADA REQUIREMENTPROJECT GENERAL NOTES

SCALE: NONE

GENERAL DEFINITIONS

1. A. DEFINITIONS: AS FOLLOWS:1. REMOVE: REMOVE AND LEGALLY DISPOSE OF ITEMS EXCEPT THOSE

INDICATED TO BE REINSTALLED, SALVAGED, OR TO REMAIN THE OWNER'S PROPERTY.2. REMOVE AND REINSTALL: REMOVE ITEMS INDICATED; CLEAN, SERVICE,

AND OTHERWISE PREPARE THEM FOR REUSE; STORE AND PROTECT AGAINSTDAMAGE. REINSTALL ITEMS IN LOCATIONS INDICATED.

3. EXISTING TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAINAGAINST DAMAGE AND SOILING DURING DEMOLITION. WHEN PERMITTED BY THEARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, PROTECTED STORAGELOCATION DURING DEMOLITION AND THEN CLEANED AND REINSTALLED IN THEIRORIGINAL LOCATIONS.

2. EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED, OR OTHERWISEINDICATED TO REMAIN THE OWNER'S PROPERTY, DEMOLISHED MATERIALS SHALLBECOME THE CONTRACTOR'S PROPERTY AND SHALL BE REMOVED FROM THE SITEWITH FURTHER DISPOSITION AT THE CONTRACTOR'S OPTION.

3. PROVIDE PHOTOGRAPHS OR VIDEO, SUFFICIENTLY DETAILED, OF EXISTINGCONDITIONS OF ADJOINING CONSTRUCTION AND SITE IMPROVEMENTS THAT MIGHT BEMISCONSTRUED AS DAMAGE CAUSED BY DEMOLITION OPERATIONS.

4. RECORD DRAWINGS AT PROJECT CLOSE OUT ACCORDING TO DIVISION 1 SECTION"CONTRACT CLOSEOUT." 1.IDENTIFY AND ACCURATELY LOCATE CAPPED UTILITIES AND OTHER SUBSURFACESTRUCTURAL, ELECTRICAL, OR MECHANICAL CONDITIONS.

5. REGULATORY REQUIREMENTS: COMPLY WITH GOVERNING ENVIRONMENTALPROTECTION AGENCIES NOTIFICATION REGULATIONS BEFORE STARTING DEMOLITION.COMPLY WITH HAULING AND DISPOSAL REGULATIONS OF AUTHORITIES HAVINGJURISDICTION.

6. OWNER ASSUMES NO RESPONSIBILITY FOR ACTUAL CONDITION OF BUILDINGS TO BEDEMOLISHED.

7. STORAGE OR SALE OF REMOVED ITEMS OR MATERIALS ON-SITE WILL NOT BEPERMITTED.

8. SURVEY THE CONDITION OF THE BUILDING TO DETERMINE WHETHER REMOVING ANYELEMENT MIGHT RESULT IN A STRUCTURAL DEFICIENCY OR UNPLANNED COLLAPSEOF ANY PORTION OF THE STRUCTURE OR ADJACENT STRUCTURES DURINGDEMOLITION.

9. PERFORM SURVEYS AS THE WORK PROGRESSES TO DETECT HAZARDS RESULTINGFROM DEMOLITION ACTIVITIES.

10. UTILITY REQUIREMENTS: LOCATE, IDENTIFY, SHUT OFF, DISCONNECT, AND SEAL ORCAP OFF INDICATED UTILITY SERVICES SERVING STRUCTURES TO BE DEMOLISHED

1. PROVIDE TEMPORARY SERVICES DURING INTERRUPTIONS TO EXISTINGUTILITIES TO REMAIN, AS ACCEPTABLE TO OWNER AND TO GOVERNING AUTHORITIES.

11. DRAIN, PURGE, OR OTHERWISE REMOVE, COLLECT, AND DISPOSE OF CHEMICALS,GASES, EXPLOSIVES, ACIDS, FLAMMABLES, OR OTHER DANGEROUS MATERIALSBEFORE PROCEEDING WITH DEMOLITION OPERATIONS.

12. EMPLOY A CERTIFIED, LICENSED EXTERMINATOR TO TREAT BUILDING AND TOCONTROL RODENTS AND VERMIN BEFORE AND DURING DEMOLITION OPERATIONS.

13. CONDUCT DEMOLITION OPERATIONS AND REMOVE DEBRIS TO ENSURE MINIMUMINTERFERENCE WITH ROADS, STREETS, WALKS, AND OTHER ADJACENT OCCUPIEDAND USED FACILITIES.

14. CONDUCT DEMOLITION OPERATIONS TO PREVENT INJURY TO PEOPLE AND DAMAGETO ADJACENT BUILDINGS, FACILITIES, AND SITE IMPROVEMENTS TO REMAIN. ENSURESAFE PASSAGE OF PEOPLE AROUND DEMOLITION AREA.

15. PROVIDE AND MAINTAIN INTERIOR AND EXTERIOR SHORING, BRACING, ORSTRUCTURAL SUPPORT TO PRESERVE STABILITY AND PREVENT MOVEMENT,SETTLEMENT, OR COLLAPSE OF BUILDINGS TO BE DEMOLISHED AND ADJACENTBUILDINGS TO REMAIN. CONSTRUCTOR TO VERIFY WITH STRUCTURAL ENGINEER THEPROPER BRACING AT ALL LOCATION.

16. EXPLOSIVES: USE OF EXPLOSIVES WILL NOT BE PERMITTED.17. USE WATER MIST, TEMPORARY ENCLOSURES, AND OTHER SUITABLE METHODS TO

LIMIT THE SPREAD OF DUST AND DIRT. COMPLY WITH GOVERNING ENVIRONMENTALPROTECTION REGULATIONS.

18. REMOVE AND TRANSPORT DEBRIS IN A MANNER THAT WILL PREVENT SPILLAGE ONADJACENT SURFACES AND AREAS.

19. COMPLETELY FILL BELOW-GRADE AREAS AND VOIDS RESULTING FROM DEMOLITIONOF BUILDINGS AND PAVEMENTS WITH SATISFACTORY SOIL MATERIALS ACCORDINGTO REQUIREMENTS SPECIFIED IN DIVISION 2 SECTION "EARTHWORK."

20. DAMAGES: PROMPTLY REPAIR DAMAGES TO ADJACENT FACILITIES CAUSED BYDEMOLITION OPERATIONS.

21. DISPOSAL: PROMPTLY DISPOSE OF DEMOLISHED MATERIALS. DO NOT ALLOWDEMOLISHED MATERIALS TO ACCUMULATE ON-SITE.

A. DO NOT BURN DEMOLISHED MATERIALS.B. TRANSPORT DEMOLISHED MATERIALS OFF OWNER'S PROPERTY AND LEGALLY

DISPOSE OF THEM

GENERAL DEMOLITION

1. DEMOLITION CONTRACTOR TO COORDINATE & REVIEW ALL CONSTRUCTIONDOCUMENTS & DETERMINE THE EXTENT OF DEMOLITION WORK & BECOMEFAMILIAR WITH THEM THOROUGHLY BEFORE PERFORMING ANY DEMOLITION WORK.BY THE ACT OF SUBMITTING A BID, THE CONTRACTOR WILL BE DEEMED TO HAVECOMPLIED WITH THE FOREGOING. TO HAVE ACCEPTED SUCH CONDITIONS AND TOHAVE MADE ALLOWANCES THEREFORE IN PREPARING HIS BID.

2. THESE DRAWINGS WERE PREPARED BASED ON INFORMATION ATTAINED FROM ASITE SURVEY - CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS IN FIELD PRIORTO DEMOLITION & NOTIFY THIS OFFICE IN CASE OF DISCREPANCIES BEFOREPROCEEDING. DEMOLITION IS TO BE EXECUTED SO AS NOT TO DISTURB EXISTINGSTRUCTURAL & ROOFING SYSTEMS. (EXCEPT WHERE NOTED) VERIFY ALLCONSTRUCTION TO BE REMOVED THAT IS NOT INTEGRAL TO STRUCTURAL SYSTEMPRIOR TO DEMOLITION.

3. CLEAN ALL EXCESS CONCRETE SPOTS, SOLID DEBRIS AND PAINT SPOTS FROMFLOOR. REMOVE ALL WAX, DIRT, GREASE, PAINTS AND ADHESIVES AS REQUIREDFOR NEW FLOOR FINISH INSTALLATION.

4. ALL FLOORS SHOULD BE LEVEL. CONCRETE FLOORS SHOULD BE TROWLEDSMOOTH AND CONFORM TO STANDARD SPECIFICATIONS AS RECOMMENDED BYPORTLAND CEMENT ASSOC.

5. CRACKS, HOLES AND DEPRESSIONS IN THE FLOORING SYSTEM SHOULD BEPORTLAND CEMENT COMPATIBLE W/ NEW FLOOR FINISHES.

6. SWEEP AND VACUUM THE FLOOR AFTER PATCHING AND DEBRIS REMOVAL. DONOT USE AN OIL BASED SWEEPING COMPOUND. ALL AREAS ARE TO BE CLEAN.

7. REMOVE ALL EXISTING MECHANICAL AND ELECTRICAL SYSTEMS NOT UTILIZED INCONSTRUCTION.

8. DEMOLITION RESPONSIBILITIES ARE NOT NECESSARILY LIMITED TO THOSE LISTEDHERE. WORK INCLUDES REMOVAL AND LEGAL DISPOSAL OF ALL EXISTINGCONSTRUCTION ITEMS THAT ARE NOT UTILIZED IN THE FINISHED PROJECT. REMOVEALL ITEMS SPECIFICALLY INDICATED IN THE DRAWINGS AND ITEMS WHICH ARENECESSARY TO BE REMOVED IN ORDER TO FACILITATE THE FINISHED PROJECT.

9. WHERE EXISTING CONCRETE SLABS ARE REMOVED FOR THE INSTALLATION OFPLUMBING OR ELECTRICAL SYSTEMS, PATCH EXISTING MATERIALS WITH:INSECTICIDE SOIL TREATMENT AT DISTURBED AREAS, 4" THICK CRUSHED ROCKSUB GRADE, 6 MIL POLY VAPOR BARRIER & CONCRETE SLAB WITH WWFREINFORCING.

10. SUBMIT WRITTEN REQUEST IN ADVANCE OF CUTTING OR ALTERING ELEMENTSWHICH AFFECT:A. STRUCTURAL INTEGRITY OF ELEMENTB. INTEGRITY OF WEATHER EXPOSED OR MOISTURE RESISTANT ELEMENTS.

11. PATCH ALL PENETRATIONS RESULTING FROM REMOVAL OF UTILITIES. FINISH TOMATCH ADJACENT SUBSTRATE AS REQ'D.

12. REMOVE EXISTING CEILING TILES, LIGHTING FIXTURES, DUCTWORK, ELECTRICALCONDUIT ETC. AT CEILINGS NOT REQUIRED IN FINISHED PROJECT

13. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF EXISTING CONDITIONS THAT AREEXPOSED DURING DEMOLITION THAT MAY AFFECT OR INTERFERE WITH ANY NEWWORK.

14. CONTRACTOR SHALL SALVAGE ANY REQUIRED MASONRY FROM DEMOLITION TOPATCH & REPAIR REMAINING MASONRY AS REQ'D.

15. ALL DIMENSIONS SHOWN AS EXISTING SHOULD BE FIELD VERIFIED BYCONTRACTOR PRIOR TO DEMOLITION.

16. REMOVE AND/OR GRIND SMOOTH ALL EXISTING PROTRUSIONS / DEPRESSIONS ORTHOSE CREATED BY DEMOLITION PROCESS IN PREPERATION FOR CONSTRUCTION

17. DEMOLITION AREAS SHOWN ARE APPROXIMATE. GC. TO VERIFY W/CONSTRUCTIONDWG'S PRIOR TO DEMOLITION

18. ALL CONCRETE TO REMAIN SHALL BE SAWCUT AT COMMON EDGE OF DEMOLITION

ELECTRICAL DEMOLITION NOTE: ELECTRICALLY DISCONNECT EXISTING ELECTRICALSERVICE. COORDINATE SHUTDOWN WITH POWER COMPANY. AFTER TESTING TODETERMINE "POWER OFF" TO EQUIPMENT, REMOVE AND DISPOSE OF ALL CONDUIT, WIRE,PANELBOARDS, WIREWAYS, DEVICES, ELECTRICAL EQUIPMENT, ETC.

PLUMBING DEMOLITION NOTES: A. UPON COMPLETION OF DEMOLITION & PRIOR TO INSTALLATION OF PLUMBING,

CONTRACTOR TO VERIFY SEWER DRAIN MATERIALS LEFT IN PLACE ARE INSERVICEABLE CONDITION AND CONFORM TO LOCAL PLUMBING ODES. i.e.APPROVED DRAIN, WASTE VENT & SEWER PIPING & FITTING MATERIALS.

B. CONTRACTOR TO TEST ALL EXISTING PLUMBING SYSTEMS FOR USABILITY, INACCORDANCE WITH LOCAL PLUMBING CODES.

C. REMOVE EXISTING PLUMBING FIXTURES, CAP & SEAL SEWER BELOW SLAB. D. ALL WATER PIPING FROM ABANDONED/REMOVED FIXTURES TO BE DISCONNECTEDFROM ITS SUPPLY PIPING SO THAT NO DEAD ENDS EXIST IN THE WATER SYSTEM. (TYPICAL)

SCOPE

THE INTENT OF THE SCOPE CONTAINED WITHIN THESE DOCUMENTS RELATES TO THEINTERIOR REMODELING/BUILD-OUT OF A MERCANTILE/RESTAURANT/(OTHER)/INTERIORSPACE CONTAINED WITHIN AN EXISTING SHELL BUILDING. THE ARCHITECT HAS NOTINSPECTED THE CONDITIONS OR THE INTEGRITY OF THE EXISTING SHELL BUILDINGAND SHALL NOT ASSUME RESPONSIBILITY OR LIABILITY FOR SAME. THERESPONSIBILITY AND LIABILITY FOR THE EXISTING SHELL BUILDING CONDITIONS ANDINTEGRITY, AND FOR THE CONFORMANCE OF THE EXISTING BUILDING SHELL TO ALLAPPLICABLE LOCAL CODES AND ENVIRONMENTAL REQUIREMENTS, IS SOLEY THAT OFOTHERS, AND NOT THAT OF THE ARCHITECT. THE ARCHITECT'S SCOPE OF WORK ISSTRICTLY LIMITED SOLELY TO THE INTERIOR BUILD-OUT OF AN EXISTING INTERIORSPACE LOCATED WITHIN AN EXISTING SHELL BUILDING.

A3.25

A3.1

4

3

2 1

A4.1

2

1

A4.1

3

A4.1

5

A4.1

4

A5.11

A

A

A3.1

5

A3.27

A3.26

3

45

6

B

B

B

B

B

BB

B

B

KNEE WALL FOR TOY TRAIN

4' -

10

1/2"

11' -

2 5

/8"

15' - 5 7/8"

12' - 0 5/8" 3 5/8" 7' - 7 1/8" 3 5/8" 7' - 7 1/8" 3 5/8"

300 SF

PREP AREA

427 SF

OFFICE

3

57 SF

MEN'S ROOM

6

57 SF

WOMEN'S ROOM

5

510 SF

SERVICE AREA

2

758 SF

RETAIL AREA

1

79 SF

WALK-IN FREEZER

7

5' - 8 3/8"2' - 1 7/8"

7

A

A A

B

W23

A2.1

11' -

11

3/8"

9' - 9"

3 5/

8"4'

- 4

5/8

"

1' - 4 1/2"16' - 7 7/8"35' - 8 7/8" 1' - 2 3/4"

55' - 0"24' - 2 7/8"

1' - 4"8' - 9" 3 5/8" 19' - 4" 3 5/8" 2' - 6 3/8" 3 5/8" 18' - 1 1/4"

2' -

7"

2' -

7"

B1

B1

B1

B1

B1

B1

AB B

A3.2

1

4

3

2

B A

8

1

2

2' - 0 5/8" 3 5/8"

B

B1

2' -

1 1

/4"

3 5/

8"

2

2' -

7 5

/8"

6

2

A6.1

A6.1

3

1

1' - 6 1/4"

LINE OF SOFFIT ABOVE

7 1/

2"8'

- 1

0 3/

4"

3' - 0"

6' -

5"

V.I.

F.

25' -

2 1

/2"

V.I.F.

79' - 8"

C

7' - 1" 32' - 1 3/4"

B B

HWH

FRIG.

PREP TABLE

POSPOS POS

UNDERCOUNTER FRIG.UNDERCOUNTER FRIG.

CANDY DISPLAYSLAT WALLSEE MILLWORKDWGS BY OTHERS

DISPLAY PODSSEE MILLWORKDWGS BYOTHERS

COTTONCANDY

TOY TRAIN IN ENCLOSURESEE MILLWORK DWGS BY OTHERS

POS

DD-26 DD-46 DD-88

LOCKERS

HOT WATERHEATER ABOVE

RACK RACK RACK

RACK

WINDOW

B.B

.

72" DISPLAY

3' - 0"

27 SF

OFFICE

3

300 SF

PREP AREA

4

57 SF

MEN'S ROOM

657 SF

WOMEN'S ROOM

5

79 SF

WALK-IN FREEZER

7

758 SF

RETAIL AREA

1

510 SF

SERVICE AREA

2

12' - 6" 4' - 4" 18' - 10"

3

A2.1

B A

SAFE BELOWCOUNTER

1

2

2

A6.1

16' - 6 1/2" 0"

SODAMACHINE

3' -

0"

TOPPINGS

UNDERCOUNTER ICE MAKER

SWING GATE

FS

FD

FS FS

FD

FSFSFS

FS

FS

FD FD

FS

DISPLAY PODSSEE MILLWORKDWGS BYOTHERS

6' -

6"

A 6" METAL STUD WITH TWOLAYER OF 5/8" TYPE 'X' GYPSUMBOARD EACH SIDE. PROVIDEINSULATION. EXTEND WALL TOUNDERSIDE OF STRUCTURE.

RATED DEMISING WALL.

B 3-5/8" METAL STUD WITH ONELAYER OF 5/8" GYPSUM BOARDEACH SIDE. EXTEND WALL TO6" ABOVE FINISHED CEILING.

2 LAYERS 5/8" TYPE'X' GYPSUM BOARD

6" METAL STUD

1 LAYERS 5/8"GYPSUM BOARD

3-5/8" METAL STUD

B1 3-5/8" METAL STUD WITH ONELAYER OF 5/8" GYPSUM BOARDONE SIDE. EXTEND WALL TO 6"ABOVE FINISHED CEILING.

INSULATION

C 6" METAL STUD WITH ONELAYER OF 3/4" PLYWOOD ANDONE LAYER OF 3/4" WOODPANELING.

1 LAYER 3/4" WOODPANELING

6" METAL STUD

1 LAYER 3/4"PLYWOOD

Revisions

I HEREBY CERTIFY THAT THESE PLANSHAVE BEEN PREPARED IN MY OFFICE

AND UNDER MY SUPERVISION ANDTHAT TO THE BEST OF MY

KNOWLEDGE , THE SAME COMPLYWITH ALL LAWS, RULES, REGULATIONS

AND ORDINANCES OF_________________________

RELATING TO STRUCTURES ANDBUILDINGS.

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

THIS

DRA

WIN

G H

AS

BEEN

PRE

PARE

D FO

R IN

FORM

ATI

ON

AL

AN

D RE

FERE

NC

E US

E O

NLY

. A

LL A

RCHI

TEC

TURA

L, C

IVIL

,ST

RUC

TURA

L, E

LEC

TRIC

AL,

MEC

HAN

ICA

L A

ND

PLUM

BIN

GC

ODE

CO

MPL

IAN

CE

AN

D A

DA IT

EMS

ARE

THE

RESP

ON

SIBI

LITY

OF

THE

ARC

HITE

CT

OF

REC

ORD

. (R

EPLA

CE

THIS

TEX

T W

ITH

ARC

HITE

CT

LOG

O, A

DDRE

SS &

PHO

NE.

)

AS NOTED

ML

C:\R

evit

Pro

ject

s\S

loan

's -

Cen

tral

_SG

uerr

a.rv

t8/

13/2

012

3:30

:02

PM

A1.1

12-4112

Slo

an's

DIM

EN

SIO

N F

LOO

R P

LAN

PR

OT

OT

YP

E

MAP

08/13/2012

1/4" = 1'-0"1 FLOOR PLAN

TRUENORTH

1/4" = 1'-0"2 FURNITURE PLAN

TRUENORTH

FLOOR PLAN GENERAL NOTESSCALE: NONE

1" = 1'-0"

WALL TYPES

1. COORDINATE ALL NEW CONSTRUCTION WITH SCOPE OF WORK TO BE PROVIDED BY LANDLORD.2. COORDINATE ALL ROUGH OPENING SIZE REQUIREMENTS WITH DOOR AND WINDOW SCHEDULES.3. REFERENCE COOLER MANUFACTURER INSTALLATION REQUIREMENTS PRIOR TO WALL FRAMING AND

COORDINATE WITH ADJACENT WALL CONSTRUCTION.4. REFERENCE POCKET DOOR MANUFACTUER REQUIREMENTS PRIOR TO WALL FRAMING AT POCKET DOOR

LOCATIONS.5. COORDINATE KNEE WALL CONSTRUCTION AT SERVICE COUNTER WITH TOY TRAIN AND MILLWORK

INSTALLATION.6. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE NOTED.7. REPAIR PORTION OF FLOOR AS REQUIRED TO MATCH EXISTING FLOOR CONSTRUCTION WHERE NEW

SANITARY WASTE LINES (FLOOR DRAINS, TOILETS, MOP SINK, ETC.) HAVE BEEN INSTALLED.

FLOOR PLAN KEYNOTESSCALE: NONE

WINDOW SCHEDULEMARK WIDTH HEIGHT SILL HEIGHT TYPE FINISH COMMENTS

W2 5' - 0" 6' - 6" 2' - 10" 7' x 6'-0" GLOSS NOTE 1

NOTES:

1. GAS FILLED WINDOW BY POLYTRONIX., SWITCHED TO PUSH BUTTON IN WOMEN'S TOILET ROOM.(OPAQUE WHEN PUSHED). PROVIDE EMERGENCY SHUTOFF IN OFFICE. CONTACT: PAUL TETRO (847)219-7129

WINDOW SCHEDULESCALE: NONE

B A

SIGNAGE ON FLOOR

1

2

TR1

TR2TR2

TR1

WB1

WB1

WB1WB1

WB3

UF-2 UF-2

T-1T-1

?UF-1

FD

FS

FD FD

FS

FS

FD

FS FS

FD

UF-2UF-2

FS

FS

FS

WB1WB1

WB1

SEALED CONCRETE

CERAMIC TILE

SCHLUTER RENO - U,SATIN ANODIZEDALUMINUM (AE)

TILE

SCHLUTER RENO - TK,SATIN ANODIZEDALUMINUM (AE) QUARRY TILE

TILE TO TILE TRANSITION

URETHANE TO TILE TRANSITION

TR1

TR2

= TRANSITION TAG##

A B

FLUSH DOOR DOUBLE SWINGING

C

AUTOMATIC SLIDING DOOR

D

PANEL DOOR

GYPSUM BOARD

3/4"x6" WOOD BASE TOMATCH STUART LUMBER#SLB1143 - STAINMAHOGANY TO MATCHCABINETRY FINISH

DALTILE MB5A BUILT-UPBASE FROM KEYSTONEIN D311 BLACK.(1 ROW OF 2x1 D311COVE BASE WITH 2ROWS OF FLAT 2x2FIELD TILE D311)

WALL TILE ABOVE

WB1 WB2

= TRANSITION TAG##

URETHANEFLOOR FINISH

WALL FINISH

WB3

EX

TE

ND

UP

WA

LL

8"

Revisions

I HEREBY CERTIFY THAT THESE PLANSHAVE BEEN PREPARED IN MY OFFICE

AND UNDER MY SUPERVISION ANDTHAT TO THE BEST OF MY

KNOWLEDGE , THE SAME COMPLYWITH ALL LAWS, RULES, REGULATIONS

AND ORDINANCES OF_________________________

RELATING TO STRUCTURES ANDBUILDINGS.

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

THIS

DRA

WIN

G H

AS

BEEN

PRE

PARE

D FO

R IN

FORM

ATI

ON

AL

AN

D RE

FERE

NC

E US

E O

NLY

. A

LL A

RCHI

TEC

TURA

L, C

IVIL

,ST

RUC

TURA

L, E

LEC

TRIC

AL,

MEC

HAN

ICA

L A

ND

PLUM

BIN

GC

ODE

CO

MPL

IAN

CE

AN

D A

DA IT

EMS

ARE

THE

RESP

ON

SIBI

LITY

OF

THE

ARC

HITE

CT

OF

REC

ORD

. (R

EPLA

CE

THIS

TEX

T W

ITH

ARC

HITE

CT

LOG

O, A

DDRE

SS &

PHO

NE.

)

AS NOTED

ML

C:\R

evit

Pro

ject

s\S

loan

's -

Cen

tral

_SG

uerr

a.rv

t8/

13/2

012

3:30

:04

PM

A1.2

12-4112

Slo

an's

NE

W F

INIS

H F

LOO

R P

LAN

PR

OT

OT

YP

E

MAP

08/13/2012

1/4" = 1'-0"1 FINISH FLOOR PLAN

TRUENORTH

FINISH PLAN GENERAL NOTESSCALE: NONE

6" = 1'-0"2 TRANSITION DETAILS

3/8" = 1'-0"

DOOR TYPES

FINISH SPECIFICATION SCHEDULESCALE: NONE

FINISH SPECIFICATIONSMARK DESCRIPTION MANUFACTURER MODEL COLOR FINISH COMMENTS

EF-1 EIFS GLOSSFRP-1 FIBRE-REINFORCED PLASTIC GLASBORD-P #85 WHITE PER OWNERPT-1 WALL PAINT BENJAMIN MOORE PER OWNERPT-2 PINK PAINT BENJAMIN MOORE 2086-40 DEEP CARNATION GLOSSPT-3 GREEN PAINT BENJAMIN MOORE PER OWNER GLOSSPT-4 LIGHT PINK PAINT BENJAMIN MOORE 2002-50 TICKLED PINK GLOSSPT-5 ORANGE PAINT BENJAMIN MOORE 2014-30 TANGY ORANGE GLOSSPT-6 BLUE PAINT BENJAMIN MOORE 2065-70 BASHFUL BLUE FLAT

SSM-1 MARBLE WHITEST-1 WOOD STAINT-1 1" WHITE HEXAGON FLOOR TILE DALTILE ROSETTE PATTERN D617 ARCTIC WHITET-3 4"x4" WALL TILE PER OWNERT-4 CR51 1x8 ROPE SMOKY TOPAZ PER OWNER

UF-1 EPOXY FLOOR FINISH PDM COATINGS GREY CONTACT BILL O'ROURKE AT PDMCOATINGS, 630.699.8703

UF-2 EPOXY FLOOR FINISH PDM COATINGS PINK SPARKLE CONTACT BILL O'ROURKE AT PDMCOATINGS, 630.699.8703

WB-1 WOOD BASE MOLDINGWC-1 WALL COVERING

= FINISH TAG. COORESPONDS TO FINISH SPECIFICATION. USED THROUGHOUT DRAWINGS.

NOTE

##

1. REMOVE EXISTING FINISH PREP AS REQUIRED AND INSTALL NEW FLOOR OR WALL TILE WHERE NEW TILEFINISH IS SCHEDULED.

2. USE BACKER-BOARD BEHIND ALL NEW TILE AREAS - REPAIR EXISTING BACKER BOARD AS/IF REQUIRED.

3" = 1'-0"3 BASE DETAIL

FINISH FLOOR PLAN KEYNOTESSCALE: NONE

DOOR SCHEDULESCALE: NONE

DOOR HARWARE SCHEDULE SETNO. QUANTITY DESCRIPTION

MANUFACTURER MODEL COMMENTS

11.5 PAIR BALL BEARING HINGES HAGER BB 12791 CLOSER NORTON 8000 SERIES1 LEVER LOCKSET - PRIVACY FUNCTION SCHLAGE1 FLOOR STOP ROCKWOOD 440

2 1.5 PAIR BALL BEARING HINGES HAGER BB 12791 CLOSER NORTON 8000 SERIES1 PUSH PAD (PUSH SIDE)1 PULL HANDLE (PULL SIDE)1 FLOOR STOP ROCKWOOD

3 1 TRACK1 LATCH BOLT ADAMS RITE1

4 2 PAIR BALL BEARING HINGES

5 1.5 PAIR BALL BEARING HINGES HAGER BB 12791 CLOSER NORTON 8000 SERIES1 PUSH BAR DETEX

DOOR HARDWARE SCHEDULESCALE: NONE

DOOR SCHEDULE

MARKDOOR DOOR

TYPEDOOR

MATERIALDOORFINISH

FRAMEMATERIAL

FRAMEFINISH

HARDWARESET COMMENTSWIDTH HEIGHT

1 6' - 0" 8' - 0" C ALUM/GLASS KYNAR PINK ALUM. KYNAR PINK BY MFR. 'STANLEY' DURA-STORM STOREFRONT2 3' - 0" 6' - 8" B S.C. WOOD PAINT H.M. PAINT3 2' - 6" 6' - 8" A S.C. WOOD PAINT H.M. PAINT 34 2' - 10" 6' - 8" D S.C. WOOD PAINT H.M. PAINT 15 2' - 10" 6' - 8" D S.C. WOOD PAINT H.M. PAINT 16 3' - 0" 6' - 8" D S.C. WOOD PAINT H.M. PAINT 27 2' - 6" 6' - 8" A S.C. WOOD PAINT H.M. PAINT 38 3' - 0" 6' - 8" A H.M. PAINT H.M. PAINT

ROOM FINISH SCHEDULENUMBER NAME WALL FINISH BASE FINISH CEILING FINISH COMMENTS

1 RETAIL AREA WALL COVERING WB1 CLG-1 REFER TO INTERIOR ELEVATIONS FOR WALL FINISHES2 SERVICE AREA WALL COVERING WB3 CLG-1 REFER TO INTERIOR ELEVATIONS FOR WALL FINISHES3 OFFICE PAINT WB3 CLG-1 REFER TO INTERIOR ELEVATIONS FOR WALL FINISHES4 PREP AREA FRP-1 WB3 CLG-2 REFER TO INTERIOR ELEVATIONS FOR WALL FINISHES5 WOMEN'S ROOM WALL TILE & WALL

COVERING ABOVEWB2 CLG-3/PT-6 REFER TO INTERIOR ELEVATIONS FOR WALL FINISHES

6 MEN'S ROOM WALL TILE & WALLCOVERING ABOVE

WB2 CLG-3/PT-6 REFER TO INTERIOR ELEVATIONS FOR WALL FINISHES

7 WALK-IN FREEZER PER MANUFACTURER PER MANUFACTURER PER MANUFACTURER

ROOM FINISH SCHEDULESCALE: NONE

NOTES:

1. ALL INTERIOR DOOR HARDWARE TO BE BRASS.

2

A2.1

12' - 0"

10' - 0"

9' - 4"9' - 4"

9' - 0"

9' - 0"

9' - 0"

A1A1 A1

A1A1A1 A1

A1A1A1 A1

A2A2A2A2A2A2A2A2A2

A1

A1

A1

A1

A1 A1

A1A1A1

A1

A1

A1

A1

A1

D2 D2

C1

B1B1

B1B1

G1

G1G1

E1

E2

3

A2.1

A1 A1 A1 A1 A1 A1 A1 A1 A1

A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1

4

A2.1

5' -

8 1

/2"

2' -

9 1

/2"

13' -

0"

43' - 0 1/2"

4' - 1"

7' - 10"

3' - 9 1/2"

10' - 6"

1' -

5"

1' - 6" 2' - 10" 2' - 10" 1' - 6" 1' - 6" 5' - 0" 5' - 0" 5' - 0" 1' - 6"5' - 0" 5' - 0" 5' - 0"

4' -

0"

4' -

0"

8' - 0" 4' - 6 1/2"

5' - 0" TYP.2' - 6"

5' - 0" 5' - 0" 3' - 3"

H1 H1

1' - 11" 1' - 11"

B A

1

2

CLG-1

CLG-3 CLG-3

CLG-1

CLG-2

CLG-1

CLG-1

CLG-2

CLG-1

CLG-1

1

D2

A2

2' - 0" 3' - 6 1/2" 1' - 6"

A2

2' - 6" 1' - 0"

TYP.

2' - 6"

1' - 3"

TYP.

2' - 6"

EQ EQ EQ EQ

3' -

9 3

/4"

EQ EQ EQ EQ

A1 A1 A1 A1

3' -

9 3

/4"

A1 D2 A1 D2 A1 D2 A1 D2 A1 D2 A1 D2 A1 D2 A1 A1

D2

D2 A1 D2 A1 D2 A1 D2 A1 D2 A1

H1

D2 A1 D2 A1 D2 A1 D2 A1 D2 A1 D2

A2

24" x 48" PARABOLICLIGHT FIXTURE

24" x 24" PARABOLICLIGHT FIXTURE

6" DIRECTIONALCAN LIGHT

CHANDELIER

48" FLUORESCENT STRIP LIGHT

WALL SCONCE

EXIT SIGN

EMERGENCY WALL LIGHT

B/EXISTING STRUCTURE15' - 6"

B/LOW CEILING10' - 0"

B/HIGH CEILING12' - 0"

CROWN MOLDING ED-270463(WWW.CROWN-MOLDINGS.COM)

?

3 5/8" METAL STUD @ 16" O.C.

LATERAL BRACING AS REQUIRED48" O.C.

EXTEND AND SECURE TO BOTTOMOF STRUCTURE AS REQUIRED

EXISTING STRUCTURE

3 5/8" METAL STUD @ 16" O.C.

LIGHT GAUGE METALFRAMING WITH GYP.BOARD FINISH

3 5/8" METAL STUD

2

3 5/8" METAL STUD - EXTENDTO STRUCTURE ABOVE ANDSECURE AS REQUIRED

LATERAL BRACING ASREQUIRED 48" O.C.

GYP. BOARD CEILING

8"

B/EXISTING STRUCTURE15' - 6"

B/LOW CEILING10' - 0"

10' - 6"

6"

3 5/8" METALSTUD @ 16" O.C.

LATERAL BRACINGAS REQUIRED

EXISTING STRUCTURE

3 5/8" METAL STUD@ 16" O.C.

5/8" GYPSUM BOARD

Revisions

I HEREBY CERTIFY THAT THESE PLANSHAVE BEEN PREPARED IN MY OFFICE

AND UNDER MY SUPERVISION ANDTHAT TO THE BEST OF MY

KNOWLEDGE , THE SAME COMPLYWITH ALL LAWS, RULES, REGULATIONS

AND ORDINANCES OF_________________________

RELATING TO STRUCTURES ANDBUILDINGS.

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

THIS

DRA

WIN

G H

AS

BEEN

PRE

PARE

D FO

R IN

FORM

ATI

ON

AL

AN

D RE

FERE

NC

E US

E O

NLY

. A

LL A

RCHI

TEC

TURA

L, C

IVIL

,ST

RUC

TURA

L, E

LEC

TRIC

AL,

MEC

HAN

ICA

L A

ND

PLUM

BIN

GC

ODE

CO

MPL

IAN

CE

AN

D A

DA IT

EMS

ARE

THE

RESP

ON

SIBI

LITY

OF

THE

ARC

HITE

CT

OF

REC

ORD

. (R

EPLA

CE

THIS

TEX

T W

ITH

ARC

HITE

CT

LOG

O, A

DDRE

SS &

PHO

NE.

)

AS NOTED

ML

C:\R

evit

Pro

ject

s\S

loan

's -

Cen

tral

_SG

uerr

a.rv

t8/

13/2

012

3:30

:07

PM

A2.1

12-4112

Slo

an's

NE

W R

EF

LEC

TE

D C

EIL

ING

PLA

N

PR

OT

OT

YP

E

SMG

08/13/2012

1. COORDINATED NEW LIGHT FIXTURES WITH MECHANICAL DIFFUSER LAYOUT AND QUANTITY. NEWLIGHT FIXTURE LOCATIONS SHALL BE PER ARCHITECTURAL REFLECTED CEILING PLAN LAYOUT.

1/4" = 1'-0"1 REFLECTED CEILING PLAN

TRUENORTH

1/4" = 1'-0"

REFLECTED CEILING LEGEND

CEILING SCHEDULESCALE: NONE

LIGHT FIXTURE SCHEDULEID QUANTITY DESCRIPTION FINISH COMMENTS

A1 68 CAN LIGHTA2 12 DIRECTIONAL CAN LIGHTB1 4 24" x 48" PARABOLICC1 1 24" x 24" PARABOLICD2 22 CHANDELIERE1 1 FLOURESCENT STRIP LIGHTE2 1 FLOURESCENT STRIP LIGHT PROVIDED BY FREEZER MANUFACTURERG1 3 EXIT SIGNH1 3 EMERGENCY WALL LIGHT

REFLECTED CEILING GENERAL NOTESSCALE: NONE

3" = 1'-0"2 SOFFIT DETAIL

1 1/2" = 1'-0"3 TOY SOFFIT

1 1/2" = 1'-0"4 SMALL SOFFIT DETAIL

CEILING SCHEDULETYPE DESCRIPTION COMMENTS

CLG-1 5/8" GYPSUM BOARD CEILING ON 3-5/8" METAL STUD FRAMINGCLG-2 24"x48" LAY-IN CEILINGCLG-3 5/8" GYPSUM BOARD CEILING ON 3-5/8" METAL STUD FRAMING

LIGHT FIXTURE SCHEDULESCALE: NONE

= CEILING TAG

NOTE

##

1 PROVIDE 24"x24" ACCESS PANEL IN BOTTOM OF GYPSUM BOARD SOFFIT FOR ACCESS TO MERCHANDISESECURITY SYSTEM. PAINT TO MATCH SOFFIT FINISH.

FINISH FLOOR PLAN KEYNOTESSCALE: NONE

NOTES:

1. ALL LIGHT FIXTURES TO BE LED.

12' - 0"

10' - 6"

10' - 0"

SHELF WC-1

WC-1

WC-1WC-1

DIGITAL MENU BOARDS

WC-1WC-1

WC-1

WC-1

WC-1

TYP.

7' - 0"5' - 0"

SSM-1

10' - 6"

SSM-1

10' - 6"

10' - 0"

WC-1

WC-1

WC-1

WC-1

PT-2

MONA LISAART

4' -

0"

2' - 6"

FRAME & ARTWORKBY OWNER.PROVIDE BLOCKINGAS NECESSARY

10' - 0"

12' - 0"

6' -

11

1/2"

2' -

0"

WALK-IN COOLER SLAT WALLSEE 3/A6.1

SECURITYEQUIPMENTABOVE SOFFIT

CANDY DISPLAY (BY G.C.)

SHELF

WC-1

WC-1

WC-1FRP-1

FRP-1

2' -

6"

4 7/

8"5'

- 1

1/8

"2'

- 0

"

SAFE IN OFFICETO BE PROVIDEDBY OWNER

UF-1

UF-1

PT-1

PT-1

PT-1

2' -

6"

2' -

0"

2' -

6"

PT-1

UF-1

PT-1

UF-1

Revisions

I HEREBY CERTIFY THAT THESE PLANSHAVE BEEN PREPARED IN MY OFFICE

AND UNDER MY SUPERVISION ANDTHAT TO THE BEST OF MY

KNOWLEDGE , THE SAME COMPLYWITH ALL LAWS, RULES, REGULATIONS

AND ORDINANCES OF_________________________

RELATING TO STRUCTURES ANDBUILDINGS.

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

THIS

DRA

WIN

G H

AS

BEEN

PRE

PARE

D FO

R IN

FORM

ATI

ON

AL

AN

D RE

FERE

NC

E US

E O

NLY

. A

LL A

RCHI

TEC

TURA

L, C

IVIL

,ST

RUC

TURA

L, E

LEC

TRIC

AL,

MEC

HAN

ICA

L A

ND

PLUM

BIN

GC

ODE

CO

MPL

IAN

CE

AN

D A

DA IT

EMS

ARE

THE

RESP

ON

SIBI

LITY

OF

THE

ARC

HITE

CT

OF

REC

ORD

. (R

EPLA

CE

THIS

TEX

T W

ITH

ARC

HITE

CT

LOG

O, A

DDRE

SS &

PHO

NE.

)

AS NOTED

ML

C:\R

evit

Pro

ject

s\S

loan

's -

Cen

tral

_SG

uerr

a.rv

t8/

13/2

012

3:30

:10

PM

A3.1

12-4112

Slo

an's

NE

W IN

TE

RIO

R E

LEV

AT

ION

S

PR

OT

OT

YP

E

SMG

08/13/2012

3/8" = 1'-0"1 FRONT ELEVATION

3/8" = 1'-0"4 LEFT ELEVATION

3/8" = 1'-0"2 BACK ELEVATION

3/8" = 1'-0"3 RIGHT ELEVATION

3/8" = 1'-0"5 OFFICE ELEVATION

3/8" = 1'-0"6 OFFICE ELEVATION

T/SLAB0' - 0"

9' -

0"

3' -

0"

PAINTED MURAL BYOWNER

METAL BAND

NEW EXTERIORSIGNAGE (N.I.C.)

PAINTED EIFS FINISH

4"2'

- 4

"

PAINTED FAUXPILASTERWOOD PANEL ON

GLAZING, BY OTHERS

3' - 6" 3' - 4" 6' - 4" 2' - 11 1/2" 3' - 1 1/2"

6' - 0"

NOTE: ALL STOREFRONT GLASS PANELS TO BE CLEAR TEMPERED GLASS

8' -

6"

8' -

0"

2

2' -

10"

6' -

6"

5' - 0" 1' - 4" LIGHTING ABOVE SHELF

WC-1WC-1

W2

GYPSUM BOARDSHELF

WB-1

9' -

4"

WALK-IN FREEZER

FRP-1FRP-1

UF-1

FRP-1FRP-1

UF-1

WALL RETURN

FREEZER DOOR

UF-1

FRP-1

?

FRP-1FRP-1

UF-1UF-1

FRP-1

UF-1

9' - 0"

6"

FRP-1 FRP-1FRP-1FRP-1

UF-1 UF-1

FRP-1

FRP-1

FRP-1

MOP BASINWING WALL

UF-1

Revisions

I HEREBY CERTIFY THAT THESE PLANSHAVE BEEN PREPARED IN MY OFFICE

AND UNDER MY SUPERVISION ANDTHAT TO THE BEST OF MY

KNOWLEDGE , THE SAME COMPLYWITH ALL LAWS, RULES, REGULATIONS

AND ORDINANCES OF_________________________

RELATING TO STRUCTURES ANDBUILDINGS.

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

THIS

DRA

WIN

G H

AS

BEEN

PRE

PARE

D FO

R IN

FORM

ATI

ON

AL

AN

D RE

FERE

NC

E US

E O

NLY

. A

LL A

RCHI

TEC

TURA

L, C

IVIL

,ST

RUC

TURA

L, E

LEC

TRIC

AL,

MEC

HAN

ICA

L A

ND

PLUM

BIN

GC

ODE

CO

MPL

IAN

CE

AN

D A

DA IT

EMS

ARE

THE

RESP

ON

SIBI

LITY

OF

THE

ARC

HITE

CT

OF

REC

ORD

. (R

EPLA

CE

THIS

TEX

T W

ITH

ARC

HITE

CT

LOG

O, A

DDRE

SS &

PHO

NE.

)

AS NOTED

ML

C:\R

evit

Pro

ject

s\S

loan

's -

Cen

tral

_SG

uerr

a.rv

t8/

13/2

012

3:30

:11

PM

A3.2

12-4112

Slo

an's

NE

W IN

TE

RIO

R, E

XT

ER

IOR

, &S

TO

RE

FR

ON

T D

ET

AIL

S

PR

OT

OT

YP

E

SMG

08/13/2012

3/8" = 1'-0"5 EXTERIOR ELEVATION

1/2" = 1'-0"7 STOREFRONT ELEVATION

1/2" = 1'-0"6 TOILET ROOM WINDOW ELEVATION

3/8" = 1'-0"1 KITCHEN ELEVATION 1

3/8" = 1'-0"4 KITCHEN ELEVATION 2

3/8" = 1'-0"3 KITCHEN ELEVATION 3

3/8" = 1'-0"2 KITCHEN ELEVATION 4

3' -

0"

SPACE FORUNDERCOUNTERREFRIGERATOR

SPACE FORUNDERCOUNTERREFRIGERATOR

3' - 0"3' - 0"3' - 0"4' - 11"2' - 8 1/2"3' - 0"2' - 8 1/2"4' - 2"3' - 6"2' - 6"1' - 4"1' - 3 1/2"3' - 0"4' - 2"4' - 2"2' - 3 3/4"3' - 0 3/4"

35' - 7 1/2"0" 16' - 6 1/2"

CORIAN BACKSPLASH

SPACE FORUNDERCOUNTERICE MAKER

SPACE FORSOFT SERVEMACHINES

4' - 8"

1' -

6"

2' -

0"

1' - 2 3/8"2' - 4 3/4"1' - 2 3/8"2' - 4 3/4"1' - 2 3/8"2' - 4 3/4"1' - 2 3/8"2' - 4 3/4"1' - 2 3/8"

GRAPHICS ON FRONTOF COUNTER

TOY TRAIN IN ENCLOSURELENGTH OF COUNTER

GRAPHICS ON FRONTOF COUNTER

Revisions

I HEREBY CERTIFY THAT THESE PLANSHAVE BEEN PREPARED IN MY OFFICE

AND UNDER MY SUPERVISION ANDTHAT TO THE BEST OF MY

KNOWLEDGE , THE SAME COMPLYWITH ALL LAWS, RULES, REGULATIONS

AND ORDINANCES OF_________________________

RELATING TO STRUCTURES ANDBUILDINGS.

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

THIS

DRA

WIN

G H

AS

BEEN

PRE

PARE

D FO

R IN

FORM

ATI

ON

AL

AN

D RE

FERE

NC

E US

E O

NLY

. A

LL A

RCHI

TEC

TURA

L, C

IVIL

,ST

RUC

TURA

L, E

LEC

TRIC

AL,

MEC

HAN

ICA

L A

ND

PLUM

BIN

GC

ODE

CO

MPL

IAN

CE

AN

D A

DA IT

EMS

ARE

THE

RESP

ON

SIBI

LITY

OF

THE

ARC

HITE

CT

OF

REC

ORD

. (R

EPLA

CE

THIS

TEX

T W

ITH

ARC

HITE

CT

LOG

O, A

DDRE

SS &

PHO

NE.

)

AS NOTED

ML

C:\R

evit

Pro

ject

s\S

loan

's -

Cen

tral

_SG

uerr

a.rv

t8/

13/2

012

3:30

:13

PM

A4.1

12-4112

Slo

an's

MIL

LWO

RK

ELE

VA

TIO

NS

PR

OT

OT

YP

E

SMG

08/13/2012

1/2" = 1'-0"1 FRONT COUNTER MILLWORK ELEVATION

1/2" = 1'-0"2 REAR COUNTER MILLWORK ELEVATION

1/2" = 1'-0"3 SLAT WALL MILLWORK ELEVATION

1/2" = 1'-0"5 FRONT COUNTER ELEVATION

1/2" = 1'-0"4 ANGLED COUNTER MILLWORK ELEVATION

A5.1

3

4

25

A5.1

6

7

8

9

PA1

PA3

PA2

PA6

PA7

PA5

30"

60"

66"

2

PF1

PF2

PA4

PF6

PF3

PF7

G.C. TO PROVIDE STEELFRAMING AS NECESSARYFOR LAVATORY SUPPORT.SEE MILLWORK DWGS BYOTHERS

30"

60"

66"

PF2

PF1

PA2

PA5

PF3

PA6

PA7

PF7

PA4

PA1

PA3

T-3

T-4

WC-1

WB2

PUSH HERE

PT-5

PT-2

PT-4

PERIMETER OFWINDOW

WB2

T-3

2' -

10"

9' -

4"

4' -

0"

WB2

T-3

WC-1

T-4

4' -

0"

WB2

T-3

WC-1

T-4

PT-5

PT-2

PT-4

1' -

5"

WB2

T-3

WC-1

T-4

4' -

0"

WB2

T-3

T-4

WC-1

WB2

WC-1

T-4

T-3

3' -

11

1/2"

T-4

WC-1

T-3

WB2

4' -

0"

Revisions

I HEREBY CERTIFY THAT THESE PLANSHAVE BEEN PREPARED IN MY OFFICE

AND UNDER MY SUPERVISION ANDTHAT TO THE BEST OF MY

KNOWLEDGE , THE SAME COMPLYWITH ALL LAWS, RULES, REGULATIONS

AND ORDINANCES OF_________________________

RELATING TO STRUCTURES ANDBUILDINGS.

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

THIS

DRA

WIN

G H

AS

BEEN

PRE

PARE

D FO

R IN

FORM

ATI

ON

AL

AN

D RE

FERE

NC

E US

E O

NLY

. A

LL A

RCHI

TEC

TURA

L, C

IVIL

,ST

RUC

TURA

L, E

LEC

TRIC

AL,

MEC

HAN

ICA

L A

ND

PLUM

BIN

GC

ODE

CO

MPL

IAN

CE

AN

D A

DA IT

EMS

ARE

THE

RESP

ON

SIBI

LITY

OF

THE

ARC

HITE

CT

OF

REC

ORD

. (R

EPLA

CE

THIS

TEX

T W

ITH

ARC

HITE

CT

LOG

O, A

DDRE

SS &

PHO

NE.

)

AS NOTED

ML

C:\R

evit

Pro

ject

s\S

loan

's -

Cen

tral

_SG

uerr

a.rv

t8/

13/2

012

3:30

:17

PM

A5.1

12-4112

Slo

an's

EN

LAR

GE

D T

OIL

ET

RO

OM

PLA

NS

&D

ET

AIL

S

PR

OT

OT

YP

E

SMG

08/13/2012

3/4" = 1'-0"1 ENLARGED TOILET ROOM PLAN

1/2" = 1'-0"6 WOMEN'S TOILET ROOM ELEVATION

1/2" = 1'-0"7 WOMEN'S TOILET ROOM ELEVATION

1/2" = 1'-0"2 MEN'S TOILET ROOM ELEVATION

1/2" = 1'-0"3 MEN'S TOILET ROOM ELEVATION

1/2" = 1'-0"4 MEN'S TOILET ROOM ELEVATION

1/2" = 1'-0"5 MEN'S TOILET ROOM ELEVATION

PLUMBING FIXTURE & ACCESSORIES SCHEDULESCALE: NONE

PLUMBING FIXTURE AND PLUMBING ACCESSORY SCHEDULEID QUANTITY DESCRIPTION REMARKS

PF1 2 FLOOR MOUNTED TOILETPF2 2 FLUSH VALVEPF3 2 WALL HUNG LAVATORYPF4 2 SINK FAUCETPF5 1 MOP BASINPF6 1 URINALPF7 2 WALL MOUNT SENSOR FAUCET

PA1 2 42" GRAB BARPA2 2 36" GRAB BARPA3 2 18" BRAB BARPA4 2 RECESSED TOILET PAPER DISPENSERPA5 2 MIRROR WITH CHANNEL FRAMEPA6 2 SOAP DISPENSER W/MOTION SENSORPA7 2 HAND DRYER

1/2" = 1'-0"8 WOMEN'S TOILET ROOM ELEVATION

1/2" = 1'-0"9 WOMEN'S TOILET ROOM ELEVATION

PLUMBING FIXTURE GENERAL NOTESSCALE: NONE

1. REFERENCE PLUMBING DRAWINGS FOR ACTUAL PLUMBING FIXTURE AND ACCESSORIES MAKE AND MODEL.2. REFERENCE ELECTRICAL DRAWINGS FOR ANY ELECTRICAL REQUIREMENTS AND COORDINATE WITH ELECTRICAL

CONTRACTOR.3. REFERENCE ADA STANDARDS FOR ALL MOUNTING HEIGHTS OF PLUMBING ACCESSORIES.4. PROVIDE ADA COMPLIANT TOILET ROOM SIGNAGE.5. MOUNT ACCESSORIES PER A0.1

NOTE:WATERPROOFING MEMBRANETO EXTEND 18" UP WALL (6" @COOLER PARTITIONS) ONCEMENT "WONDERBOARD" AND30" FROM WALL ON FLOOR.

WATERPROOFINGBELOW FLOOR FINISH

WATERPROOFINGBELOW FLOOR FINISH

CEMENT BOARD

GYPSUM BOARD

TERMINATION BAR

RESILIENT FLOORING

T/SLAB0' - 0"

WOOD TOE KICK

COUNTERTOP

GLASS TOYTRAIN COVER

3/4" MDF

6" METAL STUDFRAMING

MILLWORK OR EQUIPMENTBEHIND KNEE WALL

3/4" PLYWOOD

1/2" MDF

3' - 0"

Revisions

I HEREBY CERTIFY THAT THESE PLANSHAVE BEEN PREPARED IN MY OFFICE

AND UNDER MY SUPERVISION ANDTHAT TO THE BEST OF MY

KNOWLEDGE , THE SAME COMPLYWITH ALL LAWS, RULES, REGULATIONS

AND ORDINANCES OF_________________________

RELATING TO STRUCTURES ANDBUILDINGS.

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

THIS

DRA

WIN

G H

AS

BEEN

PRE

PARE

D FO

R IN

FORM

ATI

ON

AL

AN

D RE

FERE

NC

E US

E O

NLY

. A

LL A

RCHI

TEC

TURA

L, C

IVIL

,ST

RUC

TURA

L, E

LEC

TRIC

AL,

MEC

HAN

ICA

L A

ND

PLUM

BIN

GC

ODE

CO

MPL

IAN

CE

AN

D A

DA IT

EMS

ARE

THE

RESP

ON

SIBI

LITY

OF

THE

ARC

HITE

CT

OF

REC

ORD

. (R

EPLA

CE

THIS

TEX

T W

ITH

ARC

HITE

CT

LOG

O, A

DDRE

SS &

PHO

NE.

)

AS NOTED

ML

C:\R

evit

Pro

ject

s\S

loan

's -

Cen

tral

_SG

uerr

a.rv

t8/

13/2

012

3:30

:17

PM

A6.1

12-4112

Slo

an's

DE

TA

ILS

PR

OT

OT

YP

E

MAP

08/13/2012

3" = 1'-0"1 WATERPROOFING DETAIL

1" = 1'-0"2 SERVICE COUNTER SECTION

K23K26

K35K35K35

K35

K38

K9

K24 K24 K25

K-K-

K22

K41

B A

1

2

K42

K44 K44

K43K45

K15 K16

K9

LOCKERS

K6 K4 K5

K3 K3

K20 K1 K2

K29

K13

K11

K17

K19

K7

K14

K7K7 K46

K47

K21 K21K48

K49

LOCKERS

K23

K25K35K35K35

K24 K24

K-K-

K22

K45

5' -

0"

TO

UN

DE

RS

IDE

OF

HO

T W

AT

ER

HE

AT

ER

6' -

0"

K26K35

K42

LOCKERS

WALK-IN FREEZER UNIT

Revisions

I HEREBY CERTIFY THAT THESE PLANSHAVE BEEN PREPARED IN MY OFFICE

AND UNDER MY SUPERVISION ANDTHAT TO THE BEST OF MY

KNOWLEDGE , THE SAME COMPLYWITH ALL LAWS, RULES, REGULATIONS

AND ORDINANCES OF_________________________

RELATING TO STRUCTURES ANDBUILDINGS.

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

THIS

DRA

WIN

G H

AS

BEEN

PRE

PARE

D FO

R IN

FORM

ATI

ON

AL

AN

D RE

FERE

NC

E US

E O

NLY

. A

LL A

RCHI

TEC

TURA

L, C

IVIL

,ST

RUC

TURA

L, E

LEC

TRIC

AL,

MEC

HAN

ICA

L A

ND

PLUM

BIN

GC

ODE

CO

MPL

IAN

CE

AN

D A

DA IT

EMS

ARE

THE

RESP

ON

SIBI

LITY

OF

THE

ARC

HITE

CT

OF

REC

ORD

. (R

EPLA

CE

THIS

TEX

T W

ITH

ARC

HITE

CT

LOG

O, A

DDRE

SS &

PHO

NE.

)

AS NOTED

ML

C:\R

evit

Pro

ject

s\S

loan

's -

Cen

tral

_SG

uerr

a.rv

t8/

13/2

012

3:30

:23

PM

K1.1

12-4112

Slo

an's

NE

W E

QU

IPM

EN

T P

LAN

PR

OT

OT

YP

E

SMG

06/29/2012

1/4" = 1'-0"1 KITCHEN EQUIPMENT PLANKITCHEN EQUIPMENT SCHEDULE

SCALE: NONE

3/8" = 1'-0"5 KITCHEN ELEVATION

3/8" = 1'-0"3 KITCHEN ELEVATION

3/8" = 1'-0"4 KITCHEN ELEVATION

TRUENORTH

3/8" = 1'-0"2 KITCHEN EQUIPMENT ELEVATION 4

KITCHEN EQUIPMENT SCHEDULEITEM # QUANTITY DESCRIPTION MANUFACTURER MODEL COMMENTS

K1 1 DRINK MIXER, TRIPLE SPINDLE HAMILTON BEACH HMD400K2 1 WHIP CREAM DISPENSER CARPIGIANI KW-50K3 2 SOFT SERVE ICE CREAM MACHINE ELECTRO FREEZE 99T-RMT SUPPLIED BY OWNER.

INSTALLED BY G.C.

K4 1 ICE CREAM DIPPING CABINET MASTER BILT DD-46K5 1 ICE CREAM DIPPING CABINET MASTER BILT DD-88K6 1 ICE CREAM DIPPING CABINET MASTER BILT DD-26K7 3 DIPPER WELL FMP 117-1060K9 2 TWO DOOR UNDERCOUNTER

REFRIGERATORCONTINENTAL SW48

K11 1 DIGITAL SCALE EDLUND DFG-160 ICK13 1 BLENDER, BAR TYPE HAMILTON BEACH HBH650K14 1 ICE MAKER WITH BIN ICE-O-MATIC ICEU300HAK15 1 STAINLESS STEEL COUNTERTOP

TOPPING DISPENSERSERVER PRODUCTS 83700

K16 1 STAINLESS STEEL COUNTERTOPTOPPING DISPENSER

SERVER PRODUCTS 80540

K17 1 STAINLESS STEEL COUNTERTOP FUDGESERVER

SERVER PRODUCTS 81290

K19 1 STAINLESS STEEL COUNTERTOP FOODWARMER

STAR MFG 4RW

K20 1 CONVECTION OVEN VOLLRATH 40701K21 2 SINK BOWL, WELD-IN ADVANCE TABCO 1620A-12K22 1 STAINLESS STEEL HAND SINK WITH

SOAP & TOWEL DISPENCERJOHN BOOS PBHS-W-1410-1 W/KNEE VALVES

K23 1 THREE COMPARTMENT KITCHEN SINK JOHN BOOS 3B16204-2D18K24 2 STAINLESS STEEL WALL SHELF EAGLE WS-1248 16/4K25 1 UNDERCOUNTER AUTOMATIC

DISHWASHERINSINGER RL-30 W/DETERGENT PUMP

K26 1 TWO DOOR REACH IN REFRIGERATOR CONTINENTAL 2R TOP MOUNTEDCOMPRESSOR

K29 1 STAINLESS STEEL WORKTABLE WITHUNDERSHELF

JOHN BOOS ST6R5-3072SSK

K35 4 DRY STORAGE SHELF UNIT EAGLE GREEN EPOXY 86" POST, 4 TIERK38 1 BAG IN BOX SODA SYSTEM SUPPLIED BY OWNER.

INSTALLED BY G.C.

K39 1 HOT AND COLD WATER MIXING BRACKET T & S BRASS B-1128K40 1 PRE RINSE FAUCET WITH WALL

BRACKETT & S BRASS B-0133-B

K41 1 STAINLESS STEEL WALL SHELF EAGLE WS-1260 16/4K42 1 STAINLESS STEEL WALL SHELF EAGLE WS-1224 16/4K43 1 UNDERCOUNTER MICROWAVE VERIFY WITH OWNER VERIFY WITH

OWNERSUPPLIED BY OWNER.INSTALLED BY G.C.

K44 2 WAFFLE CONE MAKER STAR MFG. SWCBEK45 1 HOSE REEL ASSEMBLY T & S BRASS B-1403 CONTROLS BY G.C.K46 1 CHOCOLATE DISPLAY UNIT ALTERNATIVE AIRK47 1 FREESTYLE COKE MACHINE COCA COLAK48 1 DROP-IN ICE CHEST DELFIELD 203K49 1 SODA GUN COCA-COLA VERIFY WITH

OWNER

PLUMBING FIXTURE SCHEDULE

DRAIN SCHEDULE

WATER HEATER SCHEDULE

1. ALL WORK SHALL BE IN ACCORDANCE WITH THE RULES AND REGULATIONS

OF THE AUTHORITY HAVING JURISDICTION.

2. ALL AUTHORITIES HAVING JURISDICTION SHALL BE NOTIFIED AT LEAST

THREE WORKING DAYS PRIOR TO COMMENCEMENT OF WORK.

3. ALL PIPING SHALL BE ROUTED IN THE SUSPENDED CEILING SPACE UNLESS

OTHERWISE INDICATED. ALL PIPING EXPOSED TO VIEW SHALL BE ROUTED

AS HIGH AS POSSIBLE AND TIGHT TO THE UNDERSIDE OF THE STRUCTURE.

4. EXPOSED PIPING IN FINISHED AREAS SHALL BE CHROME PLATED WITH

CHROME PLATED ESCUTCHEON AT PIPE ENTRY TO FINISHED AREA.

5. SLEEVE OR CORE-DRILL FLOOR SLABS, WALLS, ETC. AS REQUIRED FOR

PIPING AND FIRE-STOP OPENING AROUND PIPE. VERIFY LOCATION OF

STRUCTURAL BEAMS, JOISTS, ETC. BEFORE DRILLING.

6. ALL OPENINGS IN DRAINAGE AND/OR VENT SYSTEMS AS A RESULT OF

INSTALLATION ROUGH-IN SHALL BE PROTECTED WITH A TEST PLUG THAT ISSECURELY LOCKED IN PLACE UNTIL FINAL FINISHED CONNECTIONS ARE

INSTALLED.

7. ALL PIPING SHALL BE CONCEALED IN WALLS AND BEHIND FIXED

FURNISHINGS UNLESS OTHERWISE INDICATED.

8. WHEREVER FOUNDATION WALLS, OUTSIDE WALLS, ROOFS, ETC. ARE

PENETRATED FOR INSTALLATION OF SYSTEMS, THEY SHALL BE PATCHED

TO MATCH EXISTING CONSTRUCTION AND SEALED WEATHER TIGHT. WORK

SHALL BE PERFORMED BY CRAFTSMEN SKILLED IN THEIR RESPECTIVE

TRADES.

9. ALL PIPING SHALL BE RUN PARALLEL TO BUILDING LINES AND SUPPORTEDAND ANCHORED AS REQUIRED TO FACILITATE EXPANSION AND

CONTRACTION. ALL PIPING SHALL BE CONCEALED EXCEPT IN UNFINISHED

SPACES. INSTALL AS REQUIRED TO MEET ALL CONSTRUCTION CONDITIONS

AND TO ALLOW FOR INSTALLATION OF OTHER WORK INCLUDING DUCTS AND

ELECTRICAL CONDUIT. AT ALL CONNECTIONS BETWEEN FERROUS PIPING

AND NONFERROUS PIPING, PROVIDE AN ISOLATING DIELECTRIC UNION.

10. PROVIDE ALL FITTINGS, ACCESSORIES, OFFSETS, AND MATERIALS

NECESSARY TO FACILITATE THE PLUMBING SYSTEM'S FUNCTIONING AS

INDICATED BY THE DESIGN AND THE EQUIPMENT INDICATED.

11. ALL DRAINAGE PIPING SHALL BE UNIFORMLY PITCHED, 1/4'' PER FOOT.

12. PROVIDE A COMPLETE SYSTEM OF SCHEDULE 40 GALVANIZED STEEL VENT

RISERS ABOVE FLOOR. ALL VENTS SHALL BE CARRIED THROUGH THE ROOF

WITH FLASHING. ALTERNATE MATERIALS MAY BE ALLOWED IF APPROVED BY

LOCAL CODE AUTHORITIES.

13. CONDENSATE AND INDIRECT DRAIN PIPING SHALL BE TYPE M COPPERTUBING UP TO 1'' ID, TYPE DWV TUBING AND FITTINGS FOR 1-1/4'' AND

LARGER SIZES.

14. PROVIDE CLEANOUTS AT THE END OF EACH HORIZONTAL RUN, AND AT THE

BASE OF ALL VERTICAL WASTE AND DRAIN PIPES. CLEANOUTS SHALL BE OF

THE SAME SIZE AS THE PIPES THEY SERVE. FIELD VERIFY LOCATION OF ALLEXISTING CLEANOUTS AND ADJUST TO NEW FINISHED FLOOR ELEVATONS

AND PROVIDE ACCESS PANELS FOR WALLS AND CEILINGS.

15. HOT AND COLD WATER PIPING SHALL BE TYPE L COPPER TUBING WITH

WROUGHT COPPER FITTINGS AND SWEAT CONNECTIONS. PROVIDE

MINIMUM 12'' HIGH FULL AIR CHAMBER AT EACH FIXTURE STOP.

16. INSULATE ALL HOT AND COLD WATER PIPING BOTH VERTICALLY AND

HORIZONTALLY, IN CEILING AND CONCEALED IN WALLS COMPLETELY.

PROVIDE 1'' PREFORMED FIBERGLASS ASJ-VB, FLAME SPREAD 25, SMOKE

DEVELOPED 50, ASTM C-547.

17. PIPING ROUTED IN EXTERIOR WALLS SHALL BE ROUTED ON WARM SIDE OF

BUILDING WALL INSULATION.

18. ACCESS PANELS SHALL BE PROVIDED WHERE CONCEALED CONTROL

DEVICES, VALVES, CLEANOUTS, ETC. ARE CONCEALED WITHIN CEILINGS

AND WALLS. WHERE ACCESS FOR ADJUSTMENT AND MAINTENANCE IS

POSSIBLE THROUGH LAY-IN SUSPENDED CEILINGS, ACCESS PANELS ARENOT REQUIRED.

19. TEST WATER SYSTEM UNDER 150 PSIG HYDROSTATIC PRESSURE, FOR

FOUR (4) HOURS MINIMUM. WHEN TESTING INDICATES MATERIALS OR

WORKMANSHIP IS DEFICIENT, REPLACE OR REPAIR AS REQUIRED, AND

REPEAT TEST UNTIL STANDARDS ARE ACHIEVED.

20. THE DOMESTIC WATER SYSTEM AND DRAINAGE SYSTEMS SHALL BE

FLUSHED AND PRESSURE TESTED. THE DOMESTIC WATER SYSTEM SHALL

BE PURIFIED.

21. DRAINAGE PIPING UNDERGROUND AND OUTSIDE THE BUILDING SHALL BECAST IRON PIPE AND FITTINGS. ALTERNATE MATERIALS MAY BE ALLOWED IF

APPROVED BY LOCAL CODE AUTHORITIES.

22. DRAINAGE PIPING INSIDE THE BUILDING SHALL BE CAST IRON PIPE AND

FITTINGS WITH SCH. 40 GALVANIZED STEEL VENTS. ALTERNATE MATERIALS

MAY BE ALLOWED IF APPROVED BY LOCAL CODE AUTHORITIES.

23. ALL FLOOR DRAINS SHALL BE CONNECTED TO THE SANITARY SEWER

SYSTEM.

24. PROVIDE A COMPLETE NATURAL GAS PIPING SYSTEM AS NOTED ON THE

DRAWINGS. PROVIDE EITHER THREADED STEEL OR MALLEABLE IRON PIPE

WITH MALLEABLE FITTINGS OR WELDED STEEL. PROVIDE ALL UNIONS,SHUT-OFF VALVES AND DIRT LEGS REQUIRED BY NFPA-54 AND GOVERNING

LOCAL CODES. PROVIDE ALL TESTS, METERS, INSPECTIONS, HANGERS AND

EQUIPMENT CONNECTIONS REQUIRED FOR A COMPLETE AND OPERATING

SYSTEM. PAINT PIPING ON ROOF WITH TWO COATS OF RUST RESISTANT

OUTDOOR PAINT.

THERMOSTATIC MIXING VALVE SCHEDULE

FOOD SERVICE EQUIPMENT NOTES PLUMBING GENERAL NOTES

PLUMBING SYMBOLS

GREASE TRAP SCHEDULE

SYMBOL/DESIGNATOR

FIXTURE TYPE MANUFACTURER MODEL NO. FINISH TRAPMOUNTING

HEIGHTCARRIER SUPPLY FITTING

STOPVALVE

REMARKS

WC-1 WATER CLOSET FLOOR MOUNTED KOHLER K-4302-6 SKYLIGHT INTEGRALRIM 17''

ABOVE FLOORNONE

SLOAN G2OPTIMA PLUS 811

INTEGRAL HANDICAPPED ACCESSIBLE KOHLER NO. K-4670-CA-6

LAV-1 LAVATORY WALL MOUNTED KOHLER K-2276 AQUAMARINEMcGUIRENO. 8872

RIM 34''ABOVE FLOOR

SMITH SERIES#700-M31

TOTOTEL5GW60#CP

McGUIRENO. H2167

PROVIDE K-9655-P5 WALL-MOUNT BRACKET HANDICAPPEDACCESSIBLE. MCQUIRE NO. 155WC STRAINER WITHTAILPIECE. INSULATE HOT WATER PIPING AND DRAIN.

MS-1 MOP SINK FLOOR MOUNTED MUSTEE 63M WHITE 3''-P --- ---CHICAGO

FAUCET 897-CP--- MOUNT VB AT 7'-6'' ABOVE FLOOR.

DESIGNATOR TYPE LOCATION SIZE MFG'R MODEL NO. TOP REMARKS

FD-1FLOORDRAIN

SERVINGAREAS

4'' SMITH 2220C8-1/2''�

NICKEL BRONZESEDIMENT BUCKET AND NB FLANGE &COLLAR

FD-2FLOORDRAIN

TOILETROOMS

4'' SMITH 2010C6''SQ

NICKEL BRONZENB FLANGE & COLLAR

FS-1FLOORSINK

SERVING 4'' SMITH 343112''SQ

NICKEL BRONZENB HALF GRATE, FLASHING CLAMP ANDSEDIMENT BUCKET

FCO-1FLOOR

CLEANOUT--- 4'' SMITH 4020 NICKEL BRONZE

WCO-1WALL

CLEANOUT--- 2'-4'' SMITH 4472 STAINLESS STEEL VANDAL PROOF SCREWS

DESIG'N TYPE MANUFACTURERMODEL

NO.

STORAGECAPACITY(GALLONS)

INPUT ELECTRICALRECOVERY@80° RISE

REMARKS

KW VOLTAGE

WH-1 WATER HEATER A O SMITH DRE-80-15 80 208 V-3Ø 77 GPH15.0

LINE SIZE BALANCING VALVE

LINE SIZE GATE VALVE

LINE SIZE UNION

LINE SIZE CHECK VALVE

LINE SIZE BALL VALVE (2'' & SMALLER) OR LINE SIZEBUTTERFLY VALVE (2-1/2'' & LARGER)

CO CLEANOUT

CWS

HWS

FLOOR CLEANOUT

SAN

GW

FCO

FLOOR DRAIN

LAVATORY

MOP SINK

FD

MS

LAV

SANITARY

VENT

S

V

WASTE

VENT THRU ROOF

WALL CLEANOUT

WATER CLOSET

VTR

W

WCO

WC

SANITARY DRAINAGE & WASTE PIPING/SEWER

SANITARY VENT PIPING

KITCHEN GREASE WASTE PIPING/SEWER

COLD WATER SUPPLY PIPING

HOT WATER SUPPLY PIPING

FLOOR SINK

FLOOR DRAIN

FLOOR CLEANOUT

TMV-1 POWERS THERMOSTATIC MIXING VALVE MODEL E480 WITH SHUT-OFFVALVES, CHECK VALVES, LOCATED ABOVE CEILING WITH ACCESS PANEL.

1. FOOD SERVICE EQUIPMENT AND FIXTURES FURNISHED BY AND INSTALLED

BY OTHERS; REFERENCE ARCHITECTURAL DRAWINGS FOR EQUIPMENT

LOCATIONS AND REQUIREMENTS.

2. PROVIDE FINAL CONNECTIONS TO EQUIPMENT WITH SHUT-OFF VALVES,

PRESSURE REGULATORS, VACUUM BREAKERS, BACKFLOW PREVENTERS,UNIONS (INSTALL UNION BETWEEN APPLIANCE AND SHUT-OFF), FLEXIBLE

CONNECTORS, FILTERS, DIRT LEGS, TRAPS, STOP VALVES, ECT. AS

SPECIFIED, AS REQUIRED BY CODE, AND AS NECESSARY TO COMPLETE

AND OPERATING EQUIPMENT.

3. CONNECT WASTE LINES OR EXTEND WASTE LINES TO FLOOR DRAINS WITHAIR GAP, CONNECT WATER SUPPLIES AND CONNECT GAS SUPPLIES.

4. COORDINATE WITH GENERAL CONTRACTOR, OWNER AND FOOD SERVICE

EQUIPMENT SUPPLIER/CONTRACTOR FOR EQUIPMENT IDENTIFICATION,

CONNECTION REQUIREMENTS, EXACT LOCATIONS AND MOUNTING

HEIGHTS.

5. REFER TO EQUIPMENT LITERATURE FOR FINAL EQUIPMENT CONNECTION

SIZE; GAS, CWS, HWS, ETC.

6. PROVIDE BACKFLOW PREVENTER TO DRINK DISPENSER, COFFEE BREWER,

ICE MACHINE, DISHWASHING MACHINE, CARBONATOR, PRE-RINSESPRAYER, ETC. AS REQUIED BY LOCAL CODE.

THIS IS AN EXISTING SHELL BUILDING THAT WILL REQUIRE NEWCONNECTION, ETC. TO SOME OF THE PLUMBING SYSTEMS. THECONTRACTORS ARE REQUIRED TO VISIT THE SITE AND FULLY ACQUAINTTHEMSELVES WITH THE EXISTING CONDITIONS AND THE DIFFICULTIESINVOLVED IN ACCOMPLISHING THE NEW WORK. PROBLEMS,DISCREPANCIES OR INFORMATION NEEDED SHALL BE SUBMITTED TO THEARCHITECT/ENGINEER IN WRITING PRIOR TO SUBMITTING A PROPOSAL.THE SUBMISSION OF PROPOSAL WILL INDICATE THAT THE CONTRACTORHAS FULLY UNDERSTOOD AND HAS INCLUDED ALL COSTS FOR THISPROJECT.

GT-1 SMITH NO. 8250 GREASE INTERCEPTOR WITH EXTENSION, 50 GPM FLOWRATE, 100 LBS GREASE CAPACITY, 4'' INLET AND 4'' OUTLET, ARECOATING INSIDE AND OUTSIDE, SLIP-RESISTANT FLUSH COVER.

Te

l. 6

30

/59

5-8

80

0

76

0 C

ree

l D

rive

Wo

od

Da

le,

IL 6

01

91

ww

w.W

CW

en

gin

ee

rs.c

om

Fa

x 6

30

/59

5-8

81

8

Revisions

I HEREBY CERTIFY THAT THESE PLANS

HAVE BEEN PREPARED IN MY OFFICE

AND UNDER MY SUPERVISION AND

THAT TO THE BEST OF MY

KNOWLEDGE , THE SAME COMPLY

WITH ALL LAWS, RULES, REGULATIONS

AND ORDINANCES OF

_________________________

RELATING TO STRUCTURES AND

BUILDINGS.

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

De

sig

nA

rch

ite

ctu

re I

nc

.1

55

0 N

. N

ort

hw

est

Hig

hw

ay

, S

uit

e 4

00

Pa

rk R

idg

e,

Illi

no

is 6

00

68

-14

63

T 8

47

.29

8.6

90

0

F 8

47

.29

8.6

96

6

Ch

ipm

an

AS NOTED

DL JT

09.12.11

H:\

11408\r

vt\

11408.r

vt

6/1

4/2

012 8

:22:3

3 A

M

P0.1

12-4112

Slo

an's

PLU

MB

ING

NO

TE

S, S

CH

ED

ULE

S A

ND

SY

MB

OLS

Ente

r addre

ss h

ere

SCALE: NONE1 PLUMBING NOTES, SCHEDULES AND SYMBOLS

B A

1

2

1/2"

3/4"

1/2

"

1/2

"

1/2

"

1/2

"

1/2

"

1/2

"

HWR

HWS

1/2"

1/2" CWS IN CABINET SPACE

1/2" CWS BELOW GRADE

1"

1"

1/2"

3/4

"

3/4

"3/4

"

3/4

"

1 1/4"

1/2"

3/4

"

1 1

/2"

1 1/4"

1/2

"

1/2

"

WC-1WC-1

LAV-1 LAV-1

MS-1

2"

HWS

HWR

WH-1

3/4

"

CWS1 1/2"

3/4

"3/4

" 3/4

"

3/4"

1"

UR-1

CWS1

/2" 1

/2"

1/2"

K21

SINK BOWL,WELD-IN

K14

ICE MAKERWITH BIN

K45

HOSE REELASSEMBLY

K22

STAINLESSSTEEL HANDSINK WITH

SOAP & TOWELDISPENCER

K38

BAG IN BOXSODA SYSTEM

K25

UNDERCOUNTERAUTOMATIC

DISHWASHER

K23

THREECOMPARTMENTKITCHEN SINK

K47

FREESTYLECOKE

MACHINE

K7

DIPPER WELL

K7

DIPPER WELLK7

DIPPER WELL

1/2"

1/2"

1 1/4"1 1/4"

3/4"

1 1

/4"

1/2

"

1 1/4"

K48

DROP-IN ICECHEST

B A

1

2

FD-1 FD-1

3" 3

"

4" 4"

4"

FD-1

4" FCOFD-1

3"

2"

FS-1

FD-1

3"

FS-1

4"

2"

4"4" FCO

4" FCO

WC

-1

WC

-1

LA

V-1

LA

V-1 WCOWCO

4" FCO

FCO

3"

3"

MS-1

2"

2"

2"

3"

4" FCO

3" 3"

FS-1

3"

FS-1

FS-1

3"

2"

4"

4"

2"

2"

UR-1

FS-1

3" FCO

3"

FS-1

3"

2"

4"

2"

GREASEINTERCEPTORGT-1

K22

STAINLESSSTEEL HANDSINK WITH

SOAP & TOWELDISPENCER

K14

ICE MAKERWITH BIN

K3

SOFT SERVEICE CREAMMACHINE

K3

SOFT SERVEICE CREAMMACHINE

K21

SINK BOWL,WELD-IN

K21

SINK BOWL,WELD-IN

K7

DIPPER WELLK7

DIPPER WELL

K7

DIPPER WELL

K25

UNDERCOUNTERAUTOMATIC

DISHWASHER

K23

THREECOMPARTMENTKITCHEN SINK

K47

FREESTYLECOKE

MACHINE

4"

K48

DROP-IN ICECHEST

FS-1

3"

Te

l. 6

30

/59

5-8

80

0

76

0 C

ree

l D

rive

Wo

od

Da

le,

IL 6

01

91

ww

w.W

CW

en

gin

ee

rs.c

om

Fa

x 6

30

/59

5-8

81

8

Revisions

I HEREBY CERTIFY THAT THESE PLANS

HAVE BEEN PREPARED IN MY OFFICE

AND UNDER MY SUPERVISION AND

THAT TO THE BEST OF MY

KNOWLEDGE , THE SAME COMPLY

WITH ALL LAWS, RULES, REGULATIONS

AND ORDINANCES OF

_________________________

RELATING TO STRUCTURES AND

BUILDINGS.

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

De

sig

nA

rch

ite

ctu

re I

nc

.1

55

0 N

. N

ort

hw

est

Hig

hw

ay

, S

uit

e 4

00

Pa

rk R

idg

e,

Illi

no

is 6

00

68

-14

63

T 8

47

.29

8.6

90

0

F 8

47

.29

8.6

96

6

Ch

ipm

an

AS NOTED

DL JT

09.12.11

H:\

11408\r

vt\

11408.r

vt

6/1

4/2

012 8

:23:0

1 A

M

P1.1

12-4112

Slo

an's

FLO

OR

PLA

N

Ente

r addre

ss h

ere

1/4" = 1'-0"2 FLOOR PLAN - DOMESTIC WATER

1/4" = 1'-0"1 FLOOR PLAN - SANITARY AND GREASE WASTE

G

LINE SIZE SHUT-OFF VALVE

LINE SIZE UNION

1/4'' TEST CONNECTION WITHBALL VALVE AND CAP

EQUIPMENT CONNECTIONWITH REDUCER IFREQUIRED

DIRT LEG, FULL SIZE OF PIPING AND6'' MINIMUM LONG

SEE PLANS FOR PIPESIZESSECONDARY PRESSURE

REGULATING VALVE NORMALLYFURNISHED WITH EQUIPMENT

INSULATION

1/2'' BELOW NUTROD MAXIMUM

NUT TOP ANDBOTTOM

SHEETMETAL HANGERSHIELD

ROD MAXIMUM 1/2'' BELOW NUT

ROD

PIPE

ROD

SHEETMETAL HANGERSHIELD

SHEETMETALHANGERSHIELD

PIPE

CLEVISHANGER

RODSHEETMETALHANGERSHIELD

PIPE

INSULATION

ROD

RODPIPEINSULATION

NUT TOP ANDBOTTOM

NUT TOP ANDBOTTOM

ROD MAXIMUM1/2'' BELOWNUT

NOTE:

1. LOCAL AND STATE AUTHORITIES HAVING JURISDICTION SHALL APPROVE THIS OR OTHER

INSTALLATION.

WIDTH OF TRENCH AT TOP OF PIPE SHALL BE 4 XDIAMETER PLUS 8'' AND WIDTH AT TOP OFTRENCH SHALL BE BY O.S.H.A. STANDARDS

BEDDING MATERIAL SHALL BECRUSHED STONE, 1/2''� TO NO.200 SIEVE IN SIZE

INITIAL BACKFILL SHALL BE NATURALSAND WHICH PASSES THRU A 3/8''SIEVE AND CONTAINS NO SILT, CLAYOR OTHER ORGANIC MATERIAL

FINAL BACKFILL SHALL BE SUITABLEMATERIAL EXCAVATED FROM THETRENCH OR PIT-RUNSAND AND GRAVEL.

SAW-CUT AND REMOVE EXISTINGCONCRETE FLOOR SLAB AND PATCH TOMATCH EXISTING.

MIN.. 6'' GRANULAR FILL,1-1/2''� TO NO. 200 SIEVE INSIZE

TYPICAL UNDERGROUNDPIPING IN TRENCH

4''

THE SUB-GRADE SHALL BEUNDISTURBED EARTH OF SUITABLEMATERIAL TO SUPPORT GENERALCONSTRUCTION OR SHALL BECOMPACTED THUS OR SHALL BEREMOVED AND REPLACED WITHBEDDING MATERIAL

2"

3"

2"

4"

3"

4"

3" 4"

4"

4"

2"

2"

2"

2"

1 1

/2"

1 1

/2"

2"

2"

2"

2"

2"

1 1

/2"

2"

2"3"

4"

4"

FD-1

FS-1FS-1

FD-1

MS-1

FD-1

WC-1

FD-1

WC-1

LAV-1

LAV-1

2"

1 1

/2"

2"

1 1

/2"

4" FCO

4" FCO

4" FCO

4" FCO

4" FCOWCO

WCO

3"

3"

2"

FS-1

FS-1

3"

3"

2"

2"

2"

2"

3"

2"

3"

FS-1

2"

UR-1

3"

3"

3" FS-13"

3" FCO

1 1

/2"

2"

2"

K21SINK

K21SINK

K22HAND SINK

K233-COMP SINK GT-1

GREASEINTERCEPTOR

3"

2"

2"

2"

2"

FD-1

3"

2"

2"

2"

2"

3"

FS-1

1/2"

1/2

"1

/2"

1/2

"1

/2"

1/2

"1

/2"

1/2

"1

/2"

1/2

"1

/2"

1 1

/4"

3/4

"3

/4"

3/4

"3/4

"

3/4"1 1/2"

1"1"

1/2"

1/2"1/2"

1/2"

1/2"

3/4"

1/2"

2" 1 1/4"

MS-1

WC-1LAV-1

LAV-1WC-1

3/4"

1 1/2"

UR-1

1/2"

1/2"

3/4"

1/2

"1

/2"

3/4

"

1/2

"

1/2

"

K233-COMP SINK

K22HAND SINK

K25GLASS WASHER

K38BAG-IN BOX

K21SINK

K21SINK

K47COKE MACHINE

K7DIPPERWELL

K7DIPPERWELL

K7DIPPERWELL

1/2"

1/2"

1 1/4"

1"

1 1

/4"

3/4"

1/2"1 1/4"

3/4"

WH-1

2"

1 1

/4"

3/4"

1 1/4"

1 1/4"

1 1/4"

3/4

"

3/4

"

1/2"

Te

l. 6

30

/59

5-8

80

0

76

0 C

ree

l D

rive

Wo

od

Da

le,

IL 6

01

91

ww

w.W

CW

en

gin

ee

rs.c

om

Fa

x 6

30

/59

5-8

81

8

Revisions

I HEREBY CERTIFY THAT THESE PLANS

HAVE BEEN PREPARED IN MY OFFICE

AND UNDER MY SUPERVISION AND

THAT TO THE BEST OF MY

KNOWLEDGE , THE SAME COMPLY

WITH ALL LAWS, RULES, REGULATIONS

AND ORDINANCES OF

_________________________

RELATING TO STRUCTURES AND

BUILDINGS.

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

De

sig

nA

rch

ite

ctu

re I

nc

.1

55

0 N

. N

ort

hw

est

Hig

hw

ay

, S

uit

e 4

00

Pa

rk R

idg

e,

Illi

no

is 6

00

68

-14

63

T 8

47

.29

8.6

90

0

F 8

47

.29

8.6

96

6

Ch

ipm

an

AS NOTED

DL JT

09.12.11

H:\

11408\r

vt\

11408.r

vt

6/1

4/2

012 8

:23:2

9 A

M

P2.1

12-4112

Slo

an's

DE

TA

ILS

/ IS

OM

ET

RIC

S

Ente

r addre

ss h

ere

SCALE: NONE1 SANITARY ISOMETRIC

SCALE: NONE2 WATER ISOMETRIC

SCALE: NONE4 TYPICAL GAS PIPING CONNECTION DETAIL

SCALE: NONE5 TYPICAL HANGER DETAIL

SCALE: NONE6 TYPICAL UNDERGROUND PIPING DETAIL

ROOFTOP UNIT SCHEDULE

DESIG'N MANUFACTURERMODEL NO.

NOMINALTONS

AIRQUANTITY

(CFM)

MIN O.A.CFM

EXTERNALSTATIC

PRESSURE("W.C.)

COOLING CAPACITY HEATING CAPACITY CONDENSER E.A.T. ELECTRICAL

ECONOMIZER E.E.R.(S.E.E.R.) REMARKS

E.A.T.(°F DB/WB)

L.A.T.(°F DB/WB)

TOTAL(MBH)

SENSIBLE (MBH)

E.A.T.(°F DB/WB)

L.A.T.(°F DB/WB)

GAS INPUT(CFH)

HEATOUTPUT

(MBH)

MIN. GASPRESSURE

AMBIENT(°F)

MIN.AMBIENT

(°F)

SUPPLYFAN H.P. PHASE VOLTAGE

RTU-1 CARRIER48TCDE08 7.5 3,000 320 1.0 80.0/67.0 58.0/57.0 83.0 44.5 68.0 99.2 125 103 5'' WC 95 40 2.9 3 208 DIFFERENTIAL

ENTHALPY 11.0 SEE NOTES

RTU-2 CARRIER48TCDE08 7.5 3,000 320 1.0 80.0/67.0 58.0/57.0 83.0 44.5 68.0 99.2 125 103 5'' WC 95 40 2.9 3 208 DIFFERENTIAL

ENTHALPY 11.0 SEE NOTES

NOTESPROVIDE UNIT WITH THE FOLLOWING ACCESSORIES;

1. ROOF CURB.2. HUMIDI-MIZER 3 STAGE DEHUMIDIFICATION SYSTEM.3. ELECTRONIC PROGRAMMABLE THERMOSTAT.4. HUMIDISTAT.5. HAIL GUARD.

VENTILATION SCHEDULE

DIFFUSER AND GRILLE SCHEDULE

EXHAUST FAN SCHEDULE

SUPPLY FAN SCHEDULE

ROOMNO. ROOM NAME AREA

(S.F.)OCCUPANT

DENSITY OCCUPANTS

PEOPLEOUTDOOR

AIRFLOW RATECFM/PERSON

AREA OUTDOORAIRFLOW RATE

CFM/SQ FT

EXHAUSTAIRFLOW RATE

CFM/SQ FT

PEOPLEOUTDOOR AIR

REQUIREDCFM

AREA OUTDOORAIR REQUIRED

CFM

EXHAUST AIRREQUIRED

CFM

TOTAL OUTDOOR AIRREQUIRED

CFM

#1 RETAIL 809 15/1000 13 7.5 0.12 - 98 98 - 196

#2SERVICE AREA(WORKROOM) 499 4/1000 2 5 0.12 - 10 60 - 70

#3 MANAGERS OFFICE 27 5/1000 1 5 0.06 - 5 2 - 7

#4 PREP AREA(WORKROOM) 302 4/1000 2 5 0.12 - 10 37 - 47

#5 WOMENS 57 - - - - 70 CFM PERWC OR UR - - 70 -

#6 MENS 57 - - - - 70 CFM PERWC OR UR - - 70 -

TOTALS 1,751 123 197 140 320

NOTE: SCHEDULE BASED ON 2009 IMC, VERIFY AND ADJUST FOR ADOPTED CODE.

PLAN MARK SERVICE MODULE BLADE MOUNTINGLOCATION FASTENING MOUNTING

FRAME MATERIAL FINISH MANUFACTURER MIODEL NO. REMARKS

S-1 SUPPLY 48" LONG4" SLOT

1/8" BARS15° DEFLECTION SIDEWALL SCREW TYPE 11 ALUMINUM NO. 26

WHITE TITUS CT-481 PROVIDE WITH INSULATED PLENUM.

S-2 SUPPLY 24" LONG3" SLOT

ADJUSTABLESLOT CEILING SCREW TYPE 2 ALUMINUM NO. 26

WHITE TITUS ML-39 PROVIDE WITH MODEL MPI-39 INSULATEDPLENUM.

S-3 SUPPLY 36" LONG2" SLOT

ADJUSTABLESLOT CEILING SCREW TYPE 2 ALUMINUM NO. 26

WHITE TITUS ML-37 PROVIDE WITH MODEL MPI-37 INSULATEDPLENUM.

S-4 SUPPLY 24"x24" ADJUSTABLELOUVER CEILING LAY-IN TYPE 3 STEEL NO. 26

WHITE TITUS TDCA

S-5 SUPPLY 12"x12" ADJUSTABLELOUVER CEILING LAY-IN TYPE 3 STEEL NO. 26

WHITE TITUS TDCA PROVIDE WITH MODEL 'TRM' RAPID MOUNTFRAME.

S-6 SUPPLY24" LONG3" WIDE

1/8" BARS15° DEFLECTION CEILING SCREW TYPE 11 ALUMINUM

NO. 26WHITE TITUS CT-481 PROVIDE WITH INSULATED PLENUM.

R1 RETURN 24"x24" 3/4'' SPACING0° DEFLECTION CEILING LAY-IN TYPE 3 ALUMINUM NO. 26

WHITE TITUS 350ZRL PROVIDE WITH MODEL 'TRM' RAPID MOUNTFRAME.

R2 RETURN 24"x24" 3/4'' SPACING0° DEFLECTION CEILING LAY-IN TYPE 3 ALUMINUM NO. 26

WHITE TITUS 350ZRL

DESIG'N MANUFACTURER MODEL NO. TYPE CFMSTATIC

PRESSURE("W.C.)

ELECTRICALFAN

DRIVEBACKDRAFT

DAMPER REMARKSWATTS VOLTAGE PHASE

EF-1 LOREN COOK GC-144 CEILINGMOUNTED 75 0.40 98 120 1 DIRECT INTEGRAL PROVIDE WITH DELUXE ALUMINUM GRILLE

EF-2 LOREN COOK GC-144 CEILINGMOUNTED 75 0.40 98 120 1 DIRECT INTEGRAL PROVIDE WITH DELUXE ALUMINUM GRILLE

NOTES:1. ALL MOTORS SHALL BE 'ODP' WITH 1.15 SERVICE FACTOR, UNLESS OTHERWISE NOTED.

DESIG'N MANUFACTURER MODEL NO. TYPE CFMSTATIC

PRESSURE("W.C.)

ELECTRICALFAN

DRIVE REMARKSH.P. VOLTAGE PHASE

SF-1 LOREN COOK 135-SQI-HP IN-LINE 600 1.00 1/2 120 1 BELT

NOTES:1. ALL MOTORS SHALL BE 'ODP' WITH 1.15 SERVICE FACTOR, UNLESS OTHERWISE NOTED.

T

RUSKIN MODEL NO. MD-35 OPPOSED BLADEDAMPER OR NO. MDRS-25 MANUAL VOLUMEDAMPER (VD) WITH LOCKING HAND QUADRANTHANDLE (RAISED PLATFORM FOR EXTERNALLYINSULATED DUCTWORK) AND AIR-TIGHT ENDBEARINGS.

MANUAL VOLUME DAMPER WITH OPERATOR (VDO),SAME DAMPER AS ABOVE WITH VENTFABRICS, INC..NO. 677 CONCEALED DAMPER REGULATOR WITH1/2'' ROD NO. 680 RIGHT ANGLE GEAR ASSEMBLYAND CHROME CEILING COVER PLATE.

FLEXIBLE DUCTWORK, FLEXMASTER TRIPLELOCK ALUMINUM DUCTWORK, MAXIMUM 2'-0''LONG.

AIRFOIL TURNING VANES, TYPICAL FOR ALLSQUARE TURNS.

TYPICAL RETURN OR EXHAUST GRILLE.

TYPICAL SUPPLY DIFFUSER.

THERMOSTAT WITH DEVICE CONTROLLED.

CONDENSATE DRAINAGE PIPING

CONDENSATE RETURN PIPING

CHILLED WATER RETURN PIPING

CHILLED WATER SUPPLY PIPING

CONDENSER WATER RETURN PIPING

CONDENSER WATER SUPPLY PIPING

GAS PIPING

HEATING WATER RETURN PIPING

HEATING WATER SUPPLY PIPING

REFRIGERANT LIQUID PIPING

REFRIGERANT SUCTION PIPING

STEAM SUPPLY PIPING

LINE SIZE GATE VALVE

LINE SIZE BALANCING VALVE

LINE SIZE CHECK VALVE

LINE SIZE UNION

LINE SIZE BALL VALVE (2'' & SMALLER) ORLINE SIZE BUTTERFLY VALVE (2-1/2'' &LARGER)

DEVICE

CD

CON

CR

CS

CWR

CWS

G

HR

HS

L

S

STM

Te

l. 6

30

/59

5-8

80

0

76

0 C

ree

l Dri

veW

oo

d D

ale

, IL

60

19

1

ww

w.W

CW

en

gin

ee

rs.c

om

Fa

x 6

30

/59

5-8

81

8

Revisions

I HEREBY CERTIFY THAT THESE PLANS

HAVE BEEN PREPARED IN MY OFFICE

AND UNDER MY SUPERVISION AND

THAT TO THE BEST OF MY

KNOWLEDGE , THE SAME COMPLY

WITH ALL LAWS, RULES, REGULATIONS

AND ORDINANCES OF

_________________________

RELATING TO STRUCTURES AND

BUILDINGS.

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

De

sig

nA

rch

ite

ctu

re I

nc

.1

55

0 N

. N

ort

hw

est

Hig

hw

ay

, Su

ite

40

0P

ark

Rid

ge

, Illin

ois

60

06

8-1

46

3

T 8

47

.29

8.6

90

0

F 8

47

.29

8.6

96

6

Ch

ipm

an

AS NOTED

DL JT

09.12.11

H:\1

1408

\rvt

\114

08.r

vt7/

31/2

012

4:12

:31

PM

M0.1

12-4112

Slo

an's

ME

CH

AN

ICA

L N

OT

ES

AN

D S

CH

ED

ULE

S

Ent

er a

ddre

ss h

ere

GENERAL

MECHANICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLEBUILDING CODES.

PERMIT: COST FOR FEES, PERMITS, TESTS AND INSPECTIONS SHALL BE PAID FOR BY THISCONTRACTOR.

THE MECHANICAL SYSTEMS SHALL BE COMPLETE WITH ALL NECESSARY APPURTENANCESFOR A COMPLETE OPERATING SYSTEM.

BASIC MATERIALS AND METHODS

MATERIALS SHALL BEAR UNDERWRITERS LABEL WHERE SUCH STANDARDS HAVE BEENESTABLISHED AND LISTED BY UNDERWRITER’S LABORATORIES, INC. MATERIALS,EQUIPMENT AND APPLIANCES SHALL CONFORM TO THE LATEST STANDARDS OF:

AMCA -AIR MOVING AND CONDITIONING ASSOCIATIONS, INC.SMACNA -SHEET METAL AND AIR CONDITIONING CONTRACTOR NATIONALASSOCIATION, INC.ASHRAE -AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONINGENGINEERS

ASME -AMERICAN SOCIETY OF MECHANICAL ENGINEERSASTM -AMERICAN SOCIETY FOR TESTING MATERIALSNEMA -NATIONAL ELECTRICAL MANUFACTURER’S ASSOCIATIONARI -AIR CONDITIONING AND REFRIGERATION INSTITUTEANSI -AMERICAN NATIONAL STANDARDS INSTITUTE

INSULATION

DUCT LINER: PROVIDE DUCT LINER FOR DUCTWORK WHERE INDICATED. DUCT LINERSHALL MEET NFPA 90A FLAME SPREAD UNDER 25, SMOKE DEVELOPED UNDER 50.

DUCT INSULATION: PROVIDE FLEXIBLE INSULATION FOR DUCT WORK WHERE INDICATED.INSULATION SHALL BE FOIL REINFORCED KRAFT FACING MEETING NFPA 90A, FLAMESPREAD UNDER 25, SMOKE DEVELOPED UNDER 50.

ALL SUPPLY, RETURN AND OUTSIDE AIR RECTANGULAR/SQUARE DUCTWORK SHALL BEINSULATED WITH 1” THICK, 3 PCF DUCT LINER. DUCT LINER SHALL BE FASTENED TO INSIDEOF DUCTWORK AS PER MANUFACTURER’S DIRECTIONS AND SMACNA “ DUCT LINERAPPLICATION STANDARD”. SIZE OF DUCTS SHALL BE INCREASED FOR DUCT LINERINSULATION. SIZES SHOWN ON PLAN ARE INSIDE FREE AREA. ALL SUPPLY, RETURN, ANDOUTSIDE AIR ROUND/OVAL DUCTWORK SHALL BE INSULATED WITH 2” THICK FLEXIBLEINSUALTION, 1 PCF DENSITY FOIL REINFORCED KRAFT FACING. DUCT WRAP SHALL BEFASTENED TO DUCTWORK AS PER MANUFACTURER’S DIRECTIONS. ROUND DIFFUSERBRANCHES SHALL BE INSULATED WITH 1” THICK FIBERGLASS SLEEVE WITH REINFORCEDFOIL JACKET AND ALL JOINTS AND TERMINATIONS SEALED WITH 4” WIDE FOIL TAPE.ROUND/OVAL SUPPLY AND RETURN DUCTWORK EXPOSED TO VIEW AND LOCATED IN THECONDITIONED SPACE SHALL NOT BE INSULATED.

PROVIDE HEAVY DENSITY (MINIMUM 6 PCF) INSULATION AT DUCTWORK TRAPEZE HANGERSFOR EXTERNALLY INSULATED DUCTWORK.

EQUIPMENT

THE MECHANICAL CONTRACTOR SHALL INSTALL MECHANICAL SYSTEMS AS SHOWN, NOTEDAND SPECIFIED. EQUIPMENT MAY NOT BE SUBSTITUTED UNLESS WRITTEN APPROVAL BYTHE ARCHITECT, ENGINEER, OR OWNER'S REPRESENTATIVE IS OBTAINED. ANY CHANGESTO THE DUCTWORK LAYOUT WILL NECESSITATE SUBMISSION OF SHEET METAL SHOPDRAWINGS FOR ENGINEER'S REVIEW. ANY UNAUTHORIZED CHANGES WILL BE REMOVEDAT CONTRACTOR'S EXPENSE, IF DEEMED NECESSARY BY ARCHITECT, ENGINEER, OROWNER'S REPRESENTATIVE.

UPON SELECTION OF THE MECHANICAL APPLIANCES, SUBMIT THE MANUFACTURUER’SINSTALLATION INSTRUCTIONS TO THE BUILDING DEPARTMENT, INCLUDING LISTING FOROUTSIDE INSTALLATION WHERE APPLICABLE.

AIR DISTRIBUTION

ALL DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED IRON SHEET METAL AND BEFABRICATED ACCORDING TO THE S.M.A.C.N.A. LOW VELOCITY DUCT MANUAL, ASHRAEHANDBOOK VOLUME "HVAC SYSTEMS AND EQUIPMENT", AND TYPICAL DUCTWORK DETAILSSHOWN IN THESE DRAWINGS. ALL ELBOWS SHALL HAVE PROPER RADIUS, OR MECHANICALCONTRACTOR SHALL PROVIDE DOUBLE THICKNESS, AIRFOIL TURNING VANES REQUIRED BYS.M.A.C.N.A. NO SQUARE THROAT ELBOWS SHALL BE INSTALLED WITHOUT DOUBLETHICKNESS TURNING VANES.

ALL FLEXIBLE DUCTWORK SHALL BE FACTORY ASSEMBLED CLASS 1 AIR DUCT (UL 181)WITH FIBERGLASS INSULATION AND REINFORCED OUTER PROTECTIVE COVER/VAPORBARRIER. FLEX DUCT SHALL MEET NFPA 90A WITH FLAME SPREAD UNDER 25, SMOKEDEVELOPED UNDER 50, AND SHALL BE RATED FOR 2" W.C. PRESSURE AND 0 TO 250DEGREE TEMPERATURE. MAXIMUM STRETCHED OUT LENGTH SHALL BE AS PER CODES.

PROVIDE UL APPROVED FIRE DAMPERS FOR ALL PENETRATIONS THROUGH FIRE RATEDWALLS, PARTITIONS, CEILINGS, AND FLOORS. INSTALL FIRE DAMPERS AS PERMANUFACTURER'S DIRECTIONS AND AS PER UL GUIDE LINES. PROVIDE ACCESS DOORS INDUCTWORK AND ACCESS PANELS IN BUILDING COINSTRUCTION AS REQUIRED FORSERVICING OF FIRE DAMPERS.

AUTOMATIC TEMPERATURE CONTROLS

CONTRACTOR SHALL FURNISH AND INSTALL ALL CONTROL WIRING AS REQUIRED.THERMOSTATS SHALL BE AS SPECIFIED OR AS FURNISHED WITH THE EQUIPMENT.PROVIDE TRANSFORMERS AS REQUIRED.

TESTING AND BALANCING SYSTEMS

BALANCING CONTRACTOR SHALL BALANCE SYSTEM TO AIR QUANTITIES SHOWN ON PLAN.BALANCING CONTRACTOR SHALL USE DUCT MOUNTED MANUAL DAMPERS FOR AIR SYSTEMBALANCING. USE OF A TERMINAL DAMPER IS NOT ACCEPTABLE.

THE ARCHITECT AND/OR OWNER’S REPRESENTATIVE SHALL BE NOTIFIED 48 HOURS ORMORE PRIOR TO ALL FINAL TESTING AND BALANCING WORK SO THAT THEY AND/OR THEENGINEER MAY BE PRESENT TO OBSERVE THIS WORK. THE BALANCING CONTRACTORSHALL SUBMIT WRITTEN REPORTS OF ALL AIR FLOW READINGS, STATIC PRESSURES, GPMRATES, PRESSURE READINGS, TEMPERATURE READINGS, MOTOR AMPERAGE, ETC., TODOCUMENT PROPERLY OPERATING AND BALANCED MECHANICAL SYSTEMS IN ALL AREAS.

MECHANICAL GENERAL NOTES1SCALE: NONE

SCALE: NONE2 MECHANICAL SYMBOLS

SCALE: NONE3 MECHANICAL NOTES AND SCHEDULES

B A

1

2

B A

1

2

LOCKERS

10"ø

12"x12"

14"x

14"

10"ø

6"ø

20"x

14"

18"x14"

6"ø

24"x16"

14"ø

6"ø

24"x16"

28"x14" 22"x14" 16"x14"

8"ø

12"x

12"

10"ø

10"ø

12"x12"14"ø

20"ø

80 CFM

S56"ø

300 CFM

S410"ø

50 CFM

S56"ø 50 CFM

S56"ø

T

T

H

H

RTU-2

300 CFM

S410"ø

EF-1

EF-2 SF-1

225 CFM

S28"ø

300 CFM

S310"ø

300 CFM

S310"ø

225 CFM

S28"ø

22"x 22"

680 CFM

R2

22"x 22"

2320 CFM

R2

22"x 22"

600 CFM

R1

22"x 22"

1500 CFM

R1

22"x 22"

1500 CFM

R1

18"ø

18"ø

6"ø

10"x12" 10"ø

10"ø

10"x12"

10"ø

10"ø

10"ø

8"ø

6"ø

8"x8"

8"x8

"

8"x8"AIR Q WHAF AIR FRESHENERINSTALL PER MANUFACTURERSINSTRUCTIONS.

600 CFM

S-1600 CFM

S-1600 CFM

S-1

600 CFM

S-1

600 CFM

S-1

600 CFM

S-1

12"ø

12"ø

12"ø

12"ø 12

18"x14"

RTU-1

250 CFM

S-610"ø

250 CFM

S-610"ø

250 CFM

S-610"ø

250 CFM

S-610"ø

250 CFM

S-610"ø

B A

1

2

RTU-2

RTU-1

8"ø TOILET EXHAUST

Te

l. 6

30

/59

5-8

80

0

76

0 C

ree

l Dri

veW

oo

d D

ale

, IL

60

19

1

ww

w.W

CW

en

gin

ee

rs.c

om

Fa

x 6

30

/59

5-8

81

8

Revisions

I HEREBY CERTIFY THAT THESE PLANS

HAVE BEEN PREPARED IN MY OFFICE

AND UNDER MY SUPERVISION AND

THAT TO THE BEST OF MY

KNOWLEDGE , THE SAME COMPLY

WITH ALL LAWS, RULES, REGULATIONS

AND ORDINANCES OF

_________________________

RELATING TO STRUCTURES AND

BUILDINGS.

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

De

sig

nA

rch

ite

ctu

re I

nc

.1

55

0 N

. N

ort

hw

est

Hig

hw

ay

, Su

ite

40

0P

ark

Rid

ge

, Illin

ois

60

06

8-1

46

3

T 8

47

.29

8.6

90

0

F 8

47

.29

8.6

96

6

Ch

ipm

an

AS NOTED

DL JT

09.12.11

H:\1

1408

\rvt

\114

08.r

vt7/

31/2

012

4:12

:39

PM

M1.1

12-4112

Slo

an's

ME

CH

AN

ICA

L F

LOO

R A

ND

RO

OF

PLA

NS

Ent

er a

ddre

ss h

ere

1/4" = 1'-0"1 MECHANICAL FLOOR PLAN

1/4" = 1'-0"2 MECHANICAL ROOF PLAN

NOTES:1. CURB SHALL BE TAPERED TYPE AND MATCH THE PITCH OF THE ROOF.2. CUT AND PATCH EXISTING ROOFING AS REQUIRED FOR NEW CURB INSTALLATION.3. SECURELY INSTALL CURB TO ROOF; USE FASTENERS AS REQUIRED BY ROOF CONSTRUCTION.

PROVIDE RIGID INSULATIONCANT STRIP, 4'' HIGH MINIMUM

PROVIDE RIGID INSULATION,THICKNESS AND HEIGHT AS REQUIREDBY CURB DIMENSIONS

PROVIDE 16 GAUGE GALVANIZED IRONCOUNTERFLASHING AND FASTEN TOWOOD NAILER WITH SCREWS, 6'' ONCENTER

OUTLINE OF MECHANICAL ROOFTOPEQUIPMENT. INSTALL TO ROOF CURBAS PER MANUFACTURER'S DIRECTION

ROOF INSULATION

ROOF CONSTRUCTION

EQUIPMENT MANUFACTURERSUPPLIED TAPERED TYPEROOF CURB. PROVIDEASSEMBLY OF CURB ASPER MANUFACTURER'SDIRECTIONS

PROVIDE TREATED WOODNAILER, THICKNESS ANDHEIGHT AS REQUIRED FORCURB DIMENSIONS. FASTENNAILER TO CURB WITHSCREWS, 6'' ON CENTER

PROVIDE OR INSTALLMANUFACTURER SUPPLIED1/4'' THICK NEOPRENERUBBER CURB GASKET

ROOF OPENING AS REQUIRED BYMECHANICAL ROOFTOP EQUIPMENT

MIM

INU

M1

2"

HIG

H

PLASTER CEILING CONSTRUCTION

VENTILATION CONTRACTORFABRICATED SUPPLYPLENUM WITH 1'' THICKDUCT LINING2'' COLLAR INLET,

SEE PLANS FORSIZES

EXTERNAL DUCTINSULATION

VENTFABRICS, INC.MODEL NO. 670 DUCTCLAMP

LINED PLENUM

DIFFUSER ASSEMBLY

FLEXIBLE DUCT

SECTION VIEW

12'' (MIN.)

SEE SECTION

VIEW

IMPROVED CONSUMERPRODUCTS MODEL STSVENT CAP, SAMESIZE AS EXHAUSTDUCT

ROOF CONSTRUCTION,SEE ARCHITECTURALDRAWINGS

OUTDOOR EXHAUSTDUCT, SAME DIMENSIONAS INSIDE EXHAUST DUCT

STORM COLLAR

TALL CONE FLASHING

ROOF OPENING

EXHAUST DUCT, SEEDRAWINGS FOR SIZES

24

" A

BO

VE

RO

OF

ROOF OPENING 1/2''LARGER THAN DUCTWORKALL AROUND

SUPPLY AIR DUCTWORK;SEE PLANS FOR SIZES

SQUARE TURN TRANSITIONELBOW WITH TURNING VANES

SUPPLY AND RETURN RISERS WITH 1'' THICK, 3 PCFFLEXIBLE DUCT LINER; DUCT DIMENSIONS SHALL BEFULL SIZE OF ROOFTOP UNIT CONNECTIONS.

STRUCTURAL MEMBER

ROUTE DUCTWORK TIGHTTO STRUCTURAL MEMBER

ROOF CONSTRUCTION

3'' THICK, 6 PCF RIGID DUCT LINER; INSTALL TOROOF IN ALL OPEN SPACES INSIDE ROOF CURB

STRUCTURAL MEMBER

RETURN AIR DUCTWORK; SEEPLANS FOR SIZES

ROUTE DUCTWORK TIGHT TOSTRUCTURAL MEMBER

3'' THICK, 6 PCF RIGID DUCT LINER; INSTALL TOUNDERSIDE OF ROOF CONSTRUCTION WITH FULL COATOF ADHESIVE AND MECHANICAL FASTENERS; SEAL ALLAROUND OPENING WITH SILICONE BASED SEALANT

DUCT SUPPORT RAILS

FLEXIBLE CONNECTOR

SUSPEND FAN FROM STRUCTUREABOVE WITH MINIMUM FOUR (4)THREADED RODS AND 95% EFFICIENT,SPRING LOADED VIBRATION ISOLATORS

FLEXIBLE CONNECTOR

FILTER SECTION; PROVIDEFILTER PULL SPACE

SUSPENDED CEILING GRID

FLEXIBLE CONNECTOR

PROVIDE ACCESS TOREMOVABLE SIDE PANEL

INLINE DUCT BLOWER; SEE SCHEDULE

NOTES:1. SEE PLANS FOR DUCT SIZES AND ROUTING.2. MOUNT DUCT BLOWER AS HIGH AS POSSIBLE.

Te

l. 6

30

/59

5-8

80

0

76

0 C

ree

l D

rive

Wo

od

Da

le,

IL 6

01

91

ww

w.W

CW

en

gin

ee

rs.c

om

Fa

x 6

30

/59

5-8

81

8

Revisions

I HEREBY CERTIFY THAT THESE PLANS

HAVE BEEN PREPARED IN MY OFFICE

AND UNDER MY SUPERVISION AND

THAT TO THE BEST OF MY

KNOWLEDGE , THE SAME COMPLY

WITH ALL LAWS, RULES, REGULATIONS

AND ORDINANCES OF

_________________________

RELATING TO STRUCTURES AND

BUILDINGS.

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

De

sig

nA

rch

ite

ctu

re I

nc

.1

55

0 N

. N

ort

hw

est

Hig

hw

ay

, S

uit

e 4

00

Pa

rk R

idg

e,

Illi

no

is 6

00

68

-14

63

T 8

47

.29

8.6

90

0

F 8

47

.29

8.6

96

6

Ch

ipm

an

AS NOTED

DL JT

09.12.11

H:\

11408\r

vt\

11408.r

vt

6/1

4/2

012 8

:21:5

8 A

M

M2.1

12-4112

Slo

an's

Deta

ils

Ente

r addre

ss h

ere

SCALE: NONE1 TYP MECH EQUIP ROOF CURB INSTL DTL

SCALE: NONE2 SUPPLY PLENUM AND DIFFUSER DETAIL

SCALE: NONE3 TYP EXHAUST DUCT THRU ROOF DETAIL

SCALE: NONE4 ROOFTOP UNIT DUCT DROP DETAIL

SCALE: NONE5 INLINE DUCT BLOWER DETAIL

ELECTRICAL SPECIFICATIONS:

E1. FURNISH AND INSTALL ALL LABOR, TOOLS, MATERIAL, EQUIPMENT, SERVICES, AND RELATEDACCESSORIES NECESSARY FOR THE COMPLETE INSTALLATION OF ELECTRICAL WORK SHOWNON THE DRAWINGS, SPECIFIED IN THE NOTES, AND REQUIRED BY LOCAL CODE AUTHORITIES.

E2. ALL WORK SHALL COMPLY WITH THE LOCAL CODES AND THEIR GOVERNING AUTHORITIES.

E3. OBTAIN AND PAY FOR ALL PERMITS AND FEES RELATING TO ELECTRICAL SYSTEM.

E4. IT IS INTENDED THAT ALL ITEMS OF WORK AND SYSTEMS BE FURNISHED AND INSTALLEDCOMPLETE IN ALL DETAILS, READY FOR SATISFACTORY OPERATION AND SERVICE. APPARATUSREQUIRED SHALL BE FURNISHED, EVEN THOUGH NOT SPECIFICALLY MENTIONED HEREIN,OR SHOWN ON THE DRAWINGS.

E5. PROVIDE GROUNDING OF ELECTRICAL WORK IN STRICT ACCORDANCE WITH THE APPLICABLECODES AND THEIR AUTHORITIES.

E6. COORDINATE ALL WORK WITH OTHER TRADES PRIOR TO ANY INSTALLATION.

E7. PROVIDE CODE APPROVED CLEARANCES AROUND ELECTRICAL EQUIPMENT.

E8. MATERIALS AND EQUIPMENT SHALL BE NEW AND SHALL CONFORM TO THE N.E.M.A., NATIONALELECTRICAL CODE (NEC), AND UNDERWRITERS LABORATORIES (UL) STANDARDS IN EVERYCASE, WHERE SUCH STANDARDS HAVE BEEN ESTABLISHED.

E9. PROVIDE EXCAVATION AND BACKFILLING REQUIRED FOR THE INSTALLATION OF ANY ANDALL PARTS OF THE ELECTRICAL WORK. PROVIDE SHEATHING, BRACING, AND OPERATE PUMPINGEQUIPMENT, IF REQUIRED, FOR THE EXCAVATION PORTION OF THE ELECTRICAL WORK.

E10. TESTING - AFTER WIRES ARE IN PLACE AND CONNECTED TO DEVICES AND EQUIPMENT,THE SYSTEM SHALL BE TESTED FOR SHORTS AND GROUNDS. ALL HOT WIRES, IF SHORTEDOR GROUNDED, SHALL BE REMOVED AND REPLACED.

E11. ALL METERS, INSTRUMENTS, CABLE CONNECTION, EQUIPMENT, OR APPARATUS NECESSARYFOR MAKING ALL TESTS, SHALL BE FURNISHED BY THIS CONTRACTOR AT HIS OWN EXPENSE.

E12. AFTER THE COMPLETION OF THE INSTALLATION, THE ENTIRE SYSTEM SHALL BE THOROUGHLYCLEANED. CLEAN ALL FOREIGN MATTER, PAINT, OIL, DIRT, UNREQUIRED LABELS, GREASE,AND STICKERS FROM FIXTURES AND EQUIPMENT. REMOVE FROM THE PREMISES ALL RUBBISH,DEBRIS, ETC. ACCUMULATED BY THE ELECTRICAL INSTALLATION.

E13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EQUIPMENT AND SYSTEMSAGAINST HARMFUL EXPOSURE, OR ACCUMULATION OF DUST/MOISTURE, FLOODING, CORROSION,OR OTHER FORMS OF DAMAGE. CLEAN AND RESTORE DAMAGED FINISHES AND EQUIPMENTTO PLACE INSTALLATION IN A LIKE-NEW CONDITION.

E14. SHOP DRAWINGS SHALL BE SUBMITTED FOR LIGHTING FIXTURES, PANELBOARDS, SWITCHBOARDS,TRANSFORMERS, DISTRIBUTION EQUIPMENT, WIRING DEVICES, AND RELATED EQUIPMENT.

E15. PROVIDE SLEEVES IN WALLS AND FLOOR SLABS FOR THE PASSAGE OF ALL CONDUITS,PIPES, AND DUCTS. SLEEVES SHALL BE SET IN PLACE IN SUFFICIENT TIME, AHEAD OFCONCRETE WORK, SO AS NOT TO DELAY THAT WORK.

E16. PERMANENT RECORDS - UPON COMPLETION OF THE INSTALLATION, FURNISH TO THE OWNERWIRING DIAGRAMS OF SPECIAL EQUIPMENT, LOW VOLTAGE SYSTEMS AND CONTROLS ALONGWITH RECORD DRAWINGS. CATALOGS AND OPERATING INSTRUCTIONS FOR ALL EQUIPMENTAND CONTROLS SHALL BE ASSEMBLED, BOUND, AND GIVEN TO THE OWNER AS A GUIDE FORFUTURE OPERATION AND REPAIR.

E17. GUARANTEE - ALL ITEMS, MATERIALS, AND WORKMANSHIP FURNISHED UNDER THIS SPECIFICATIONSHALL BE GUARANTEED FOR A PERIOD OF ONE(1) YEAR, AFTER ACCEPTANCE OF THE WORKAS EVIDENCED BY THE DATE OF FINAL CERTIFICATE. ANY DEFECTIVE MATERIAL OR FAULTYWORKMANSHIP SHALL BE REPLACED WITHOUT COST TO OWNER.

E18. TEMPORARY SERVICES - ARRANGE FOR SOURCES OF TEMPORARY CONSTRUCTION SERVICES.SUCH SERVICES SHALL BE NOMINALLY 120/208 VOLT, 3 PHASE, 4 WIRE FROM WHICH ACOMPLETE SYSTEM OF TEMPORARY POWER AND LIGHTING SHALL BE INSTALLED FOR ALL CONSTRUCTIONNEEDS.

E19. UNLESS SPECIFICALLY NOTED OTHERWISE, ALL WIRING SHALL BE INSTALLED IN CONDUIT.

E20. ELECTRICAL METALLIC TUBING - UNLESS NOTED OTHERWISE, EMT "THINWALL" CONDUITSHALL BE UTILIZED, IN GENERAL, WHERE PERMITTED BY CODE. MINIMUM SIZE CONDUITSHALL BE 3/4", UNLESS SPECIFICALLY NOTED OTHERWISE.

E21. CONDUIT SHALL BE AS MANUFACTURED BY ALLIED, TRIANGLE OR APPROVED EQUAL.

E22. HEAVY-WALL STEEL CONDUIT - SHALL BE EITHER HOT DIPPED GALVANIZED OR SHERARDIZEDAND BE UTILIZED:A. FOR ALL UNDERGROUND EXTENSIONS EITHER DIRECTLY BURIED IN EARTH OR IN CONCRETE

ENVELOPES AS CALLED FOR ON THE DRAWINGS.B. FOR ALL EXTENSIONS BURIED IN OR UNDER FLOOR SLABS AND/OR FOUNDATION WALLS

IN DIRECT CONTACT WITH EARTH.C. IN MOIST LOCATIONS.D. IN ALL LOCATIONS WHERE CONDUIT IS SUBJECT TO MECHANICAL DAMAGE.E. ALL FEEDERS OF TRADE SIZE 1-1/2" OR LARGER.

E23. ALL CONDUIT AND WIRING SHALL BE CONCEALED WHEREVER POSSIBLE. WHERE CONDUITAND WIRE CANNOT BE CONCEALED, PROVIDE WIREMOLD OR SURFACE MOUNTED CONDUIT ROUTEDAS DIRECTED BY THE ARCHITECT.

E24. ALL EXPOSED CONDUITS SHALL BE RUN PARALLEL TO OR AT RIGHT ANGLES TO STRUCTURALMEMBERS. CAREFULLY COORDINATE EXACT ROUTING WITH THE ARCHITECT'S REPRESENTATIVE,IN THE FIELD, PRIOR TO ANY INSTALLATION.

E25. ALL CONDUITS SHALL BE INDEPENDENTLY SUPPORTED FROM THE BUILDING STRUCTURE.CONDUIT SHALL NOT BE SUPPORTED FROM VENTILATING DUCTS, MECHANICAL PIPING, SUSPENDEDCEILING GRIDS, OR THEIR HANGERS.

E26. WIRES AND CABLES - ALL WIRE SHALL BE COPPER, 600 VOLT RATED INSULATION, TYPETHHN/THWN. WIRE SHALL BE SOLID FOR #12, AND SMALLER AND STRANDED FOR SIZE #10AND LARGER.

E27. OUTLET, PULL, AND JUNCTION BOXES SHALL BE 12 GAUGE, OR HEAVIER, STEEL, SHERARDIZEDWITH REMOVABLE KNOCKOUTS. BOXES SHALL BE AS MANUFACTURED BY APPLETON, STEELCITY, OR RAYCO.

E28. DISCONNECT SWITCHES SHALL BE HEAVY-DUTY, QUICK-MAKE, QUICK-BREAK TYPE INNEMA I ENCLOSURE. SWITCHES SHALL BE AS MANUFACTURED BY SQUARE D, EATON,SIEMENS OR GENERAL ELECTRIC.

E29. FURNISH AND INSTALL ALL FUSES AS MANUFACTURED BY BUSSMAN. FUSES SHALL BEDUAL ELEMENT TYPE UNLESS NOTED OTHERWISE.

E30. WIRING DEVICES SHALL BE SPECIFICATION GRADE. TOGGLE SWITCHES SHALL BE QUIETTYPE RATED 20AMP, 12O VOLT. DUPLEX RECEPTACLES SHALL BE RATED 20AMP, 12O VOLTGROUNDED. SPECIAL RECEPTACLES SHALL BE PROVIDED AS REQUIRED. COVERPLATE FINISHFOR ALL DEVICES SHALL BE AS DIRECTED BY ARCHITECT. WIRING DEVICES SHALL BEAS MANUFACTURED BY PASS & SEYMOUR, HUBBELL, OR GENERAL ELECTRIC.

E31. MOTOR STARTERS SHALL BE PROVIDED FOR ALL MOTORS SHOWN ON THE DRAWINGS, UNLESSSPECIFICALLY NOTED OTHERWISE.A. PROVIDE SUITABLE STARTING AND CONTROLLING EQUIPMENT FOR ALL MOTORS SHOWN

ON THE DRAWINGS.B. PROVIDE ALL STOP-START PUSHBUTTONS AND/OR HAND-OFF-AUTO SWITCHES AND OTHER

DEVICES, INCLUDING PILOT LIGHTS REQUIRED FOR THE MANUAL OR AUTOMATIC ACTUATIONOF MOTOR STARTING EQUIPMENT. DEVICES INDICATED AS BEING REQUIRED IN STARTERCOVERS SHALL BE DELIVERED SO MOUNTED TO THE PROJECT. WHERE DRAWINGS INDICATETHAT DEVICES ARE TO BE MOUNTED SEPARATELY FROM THE MOTOR STARTERS, SUCHDEVICES SHALL BE FURNISHED COMPLETE WITH NEMA CLASS I GENERAL PURPOSE ENCLOSURES.

C. STARTERS FOR MOTORS 1/2 HORSEPOWER AND OVER SHALL BE COMBINATION MAGNETICACROSS THE LINE TYPE WITH FUSED OR UNFUSED LINE DISCONNECT SAFETY SWITCHAS NOTED ON THE DRAWINGS.

D. STARTERS SHALL BE INDIVIDUALLY EQUIPPED WITH CONTROL CIRCUIT TRANSFORMERSAND OPERATING COILS TO PERMIT 110/120 VOLT CONTROL CIRCUIT OPERATION.CONTROL CIRCUIT FUSING SHALL ALSO BE PROVIDED FOR EACH STARTER. EACH MAGNETICSTARTER SHALL BE FURNISHED WITH 3 POLE OVERLOAD RELAY FOR THE MOTOR CONTROLLED,AND SHALL PROVIDE LOW VOLTAGE PROTECTION OF LOW VOLTAGE RELEASE AS DETERMINEDBY THE CONTROL WIRING METHOD USED.

E. EACH STARTER SHALL BE PROVIDED WITH TWO SETS OF N.O. AND N.C. AUXILIARYCONTACTS.

F. STARTERS FOR MOTORS LESS THAN 1/2 HORSEPOWER SHALL BE THE SINGLE POLETHERMAL OVERLOAD SWITCH TYPE. OVERLOAD UNITSB SHALL BE PROVIDED SUITABLEFOR THE MOTOR CONTROLLED. THERMAL OVERLOAD SWITCHES SHALL BE FURNISHEDCOMPLETE WITH NEMA CLASS I ENCLOSURES, AND SHALL BE GANGED WITH PILOT LIGHTSAND OTHER DEVICES WHERE SO SCHEDULED ON THE DRAWINGS.

E32. ALL EQUIPMENT LOCATED OUTDOORS SHALL BE WEATHERPROOF TYPE.

E33. EXPANSION FITTINGS - PROVIDE EXPANSION FITTINGS FOR CONDUITS CROSSING EXPANSIONJOINTS.

E34. CONNECTIONS - ALL MAIN FEEDER CONNECTIONS SHALL BE MADE WITH SOLDERLESS CONNECTORS,BOLTED TYPE. SMALLER WIRE SPLICES SHALL BE MADE WITH PRESSURE TYPE CONNECTORS- MINNESOTA MINING "SKOTCHLOCKS" OR IDEAL "WINGNUTS".

E35. PANELBOARDS SHALL BE AS SHOWN ON THE DRAWINGS WITH MAIN LUGS, MAIN BREAKERS,BRANCH BOLT-ON BREAKERS, SPARES, AND SPACES AS SCHEDULED. PROVIDE G.F.I. BREAKERSAS REQUIRED. PANELBOARDS SHALL BE SQUARE D, EATON, SEIMENS OR GENERALELECTRIC TYPE.

E36. PROPERLY LABEL ALL PANELBOARD DIRECTORIES FOR NEW WORK INVOLVED. DIRECTORIESSHALL BE TYPEWRITTEN.

E37. FURNISH AND INSTALL A COMPLETE AND OPERABLE SYSTEM OF SERVICE AND DISTRIBUTIONFROM THE UTILITY COMPANY PAD MOUNTED TRANSFORMERS TO THE MAIN SWITCHBOARDS ASSHOWN ON THE DRAWINGS. EXTEND DISTRIBUTION FROM THE MAIN SWITCHBOARDS AS FOLLOWS:A. 277/480 VOLTS, 3 PHASE, 4 WIRE FOR BUILDING LIGHTING, POWER, ELECTRIC

HEATING, AND AIR CONDITIONING.B. 120/208 VOLT, 3 PHASE, 4 WIRE FOR TENANT LOADS AND BUILDING RECEPTACLE

AND INCANDESCENT LIGHTING.

E38. MAIN SWITCHBOARDS SHALL CONTAIN COPPER BUSSING SIZED AS INDICATED ON THEDRAWINGS, WITH MAIN BOLTED PRESSURE TYPE SWITCHES AND BRANCH QM-QB FUSIBLE SWITCHES.SWITCHBOARDS SHALL BE AS MANUFACTURED BY SQUARE D.

E39.

E40. FURNISH AND INSTALL LIGHTING FIXTURES COMPLETE WITH LAMPS, HANGERS, AND CONTROLSAS SHOWN ON THE DRAWINGS AND IN THE LIGHTING FIXTURE SCHEDULE.

E41. FURNISH AND INSTALL A COMPLETE FIRE ALARM SYSTEM TO INCLUDE EQUIPMENT, WIRING,CONDUIT OUTLET AND JUNCTION BOXES, AND ACCESSORIES TO ERRECT A ZONED, NONCODED,CONTINUOUS RINGING SYSTEM AS REQUIRED BY THE LOCAL CODE AUTHORITIES.

E42.

E43.

E44. THIS CONTRACTOR SHALL PROVIDE CUTTING AND PATCHING OF EXISTING WALLS ANDFLOOR AFFECTED BY THE NEW WORK. PATCHING SHALL MATCH EXISTING, AND SHALL BECOORDINATED WITH THE OWNER'S REPRESENTATIVE.

THE CONTRACTOR SHALL REMOVE EXISTING CEILING SYSTEMS, IF REQUIRED, TO INSTALLNEW CONDUIT AND WIRING. AT COMPLETION OF NEW WORK, THIS CONTRACTOR SHALL REPLACEAND MATCH FINISH OF THE EXISTING CEILING.

COORDINATE STAGING OF MATERIAL WITH BUILDING MANAGEMENT REPRESENTATIVE ATTIME OF BIDDING.

THE SUSPENDED CEILING SPACE (IS OR IS NOT) UTILIZED AS (RETURN AIR OR SUPPLYAIR) A PLENUM SPACE. ALL WORK SHALL COMPLY WITH LOCAL CODE REQUIREMENTS FORINSTALLATION IN PLENUM CEILING SPACES.

GENERAL NOTES:

1. COORDINATE ALL WORK WITH THE GENERAL CONTRACTOR TO LEAST INTERFERE WITH THEOWNER'S USE OF THE FACILITY. GENERAL CONTRACTOR MAY REQUIRE WORK INTERRUPTIONSDURING THE DAY AND MAY REQUIRE CERTAIN WORK TO BE PERFORMED ON PREMIUM TIMEAT NIGHT OR ON WEEKENDS.

SCHEDULE ANY DISCONNECTIONS AND RECONNECTION WITH THE CONTRACTING OFFICER. SEVENTYTWO (72) HOURS NOTICE IS REQUIRED. ARRANGE WORK SO AS NOT TO INTERRUPT ANYELECTRICAL POWER, TELEPHONE, FIRE, COMMUNICATIONS AND OTHER SYSTEMS DURING NORMALBUILDING HOURS.

WHERE CORE DRILLING AND CUTTING OF FLOORS OR WALLS IS REQUIRED, CONTRACTOR SHALLUSE XRAY EQUIPMENT, METAL DETECTORS OR OTHER APPROVED DEVICES TO DETERMINE ANDAVOID INTERFERENCE WITH EXISTING CONCEALED FEEDERS AND PIPES.

USE TEMPORARY CABLES AND ELECTRICAL APPARATUS AS REQUIRED.

THE CONTRACTOR SHALL USE GREAT DILIGENCE AND CARE IN DISCONNECTING VARIOUS SYSTEMS.RECONNECT SYSTEMS THAT SERVE ADJACENT AREAS IF SUCH SYSTEMS HAVE BEEN DISRUPTEDDURING DEMOLITION WORK.

2. UNLESS NOTED OTHERWISE, MOUNTING HEIGHTS OF ALL ELECTRICAL EQUIPMENT SHALLBE AS SHOWN ON THE ARCHITECTURAL DRAWINGS.

3. ELECTRICAL DRAWINGS ARE DIAGRAMMATICAL ONLY. FOR EXACT LOCATION OF ALL LIGHTINGFIXTURES, RECEPTACLES, ETC., REFER TO ARCHITECTURAL DRAWINGS OR QUESTION ARCHITECT.

4.

5. CIRCUIT NUMBERS ARE SHOWN FOR A GUIDE ONLY. EXACT CIRCUITS TO BE UTILIZEDSHALL BE VERIFIED IN THE FIELD. UPDATE RECORD DRAWINGS WITH EXACT CIRCUITSUTILIZED.

6. ALL RELOCATED LIGHTING FIXTURES SHALL BE CLEANED, RELAMPED AND TESTED PRIORTO REINSTALLATION.

7. PROVIDE CUTTING AND PATCHING OF EXISTING WALLS AFFECTED BY THE NEW ELECTRICALWORK. PATCHING SHALL MATCH EXISTING AND SHALL BE COORDINATED WITH THE GENERALCONTRACTOR.

8.

9. REFER TO ARCHITECTURAL DRAWINGS FOR ALL FIRE RATED AND SMOKE RATED WALLS.SEAL ALL CONDUIT PENETRATIONS THROUGH SUCH WALLS IN ACCORDANCE WITH SPECIFICATIONS.

10. CONTRACTOR SHALL REFER TO THE MECHANICAL DRAWINGS FOR THE EXACT SIZE, NUMBERAND LOCATION OF ALL MECHANICAL EQUIPMENT. PROVIDE ELECTRICAL CONNECTIONS ASREQUIRED FOR A COMPLETE AND OPERABLE SYSTEM.

11.

12. EXISTING WALL CONSTRUCTION VARIES. SOME WALLS WILL REQUIRE ADDITIONAL WORKWHILE CUTTING AND PATCHING. COORDINATE LOCATIONS WITH GENERAL CONTRACTOR ANDOWNERS REPRESENTATIVE AND INCLUDE ALL RELATED COSTS IN BASE BID PROPOSAL.

13.

14.

15.

16. ALL OUTLETS MOUNTED ABOVE COUNTER SHALL BE INSTALLED HORIZONTALLY AND NOTVERTICALLY. IN AREAS WHERE COUNTERS ARE PROVIDED, COORDINATE EXACT LOCATIONOF OUTLETS AND WIRING WITH CASEWORK

17. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 3' OF AIR SUPPLY DIFFUSERS.

18.

19.

20. CONTRACTOR SHALL VISIT THE SITE AND CAREFULLY EXAMINE THE BUILDING ELECTRICALSYSTEMS SO AS TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS AND DIFFICULTIESTHAT WILL ATTEND THE EXECUTION OF THE WORK, BEFORE SUBMITTING PROPOSALS. SUBMISSIONOF A PROPOSAL SHALL BE EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE AND LATERCLAIMS FOR LABOR, EQUIPMENT OR MATERIALS BECAUSE OF DIFFICULTIES ENCOUNTERED,WILL NOT BE RECOGNIZED.

21.

22.

23.

24. EXISTING SYSTEMS SUCH AS FIRE ALARM, COMMUNICATION SYSTEMS, SECURITY SYSTEM,ETC. ARE TO BE EXTENDED AND INTERFACED WITH NEW WORK IF REQUIRED. ARRANGE FORTHE ON-SITE INSPECTION AND GUIDANCE OF THE MANUFACTURER'S REPRESENTATIVE PRIORTO THE START OF THE WORK. PROVIDE ALL MATERIALS, DEVICES AND COMPONENTS ASINDICATED SO THAT THE EXISTING AND NEW SYSTEMS SHALL BE PROPERLY INTERFACEDAND FUNCTION AS ONE SYSTEM.

25. WHERE EXISTING DEVICES AND FIXTURES ARE TO REMAIN BUT ARE AFFECTED BY NEWWORK SUCH AS RECONDITIONING OF WALLS AND CEILINGS, DISCONNECT THESE DEVICES,FIXTURES, RACEWAYS, ETC. CLEAN AND REINSTALL SAME IN LINE WITH NEW WALLS ANDCEILINGS. PROVIDE ALL NECESSARY MATERIALS, LABOR AND REWIRE IN ACCORDANCE WITHPRESENT CODE REQUIREMENTS.

26. ALL ELECTRICAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH THE PROJECT SPECIFICATIONSAND ALL OTHER DRAWINGS RELATED TO THE PERFORMANCE OF THE WORK.

27. BECOME THOROUGHLY FAMILIAR WITH THE PROJECT SPECIFICATIONS BEFORE COMMENCINGANY WORK. THE PROJECT SPECIFICATIONS AND DRAWINGS FORM THE BASIS OF THIS CONTRACTREQUIREMENTS AND INCLUDE THE TYPE AND GRADE OF MATERIALS TO BE INSTALLED, EQUIPMENTTO BE FURNISHED, THE MANNER BY WHICH TO BE INSTALLED AND WHERE TO BE LOCATED.IN THE EVENT OF A CONFLICT BETWEEN THE PROJECT SPECIFICATIONS AND DRAWINGS,SPECIFICATIONS GOVERN UNLESS THE ARCHITECT/ENGINEER DIRECTS OTHERWISE.

28. CHECK CAREFULLY ALL CONSTRUCTION DRAWINGS AND SPECIFICATIONS THAT ARE PARTOF THIS PROJECT TO INSURE THAT NO FIXTURE, OUTLET, ALARM STATION OR CONTROLAND POWER WIRING IS OMITTED. CONTRACTOR SHALL CONSULT ALL TRADES FURNISHINGEQUIPMENT AND OBTAIN FROM THEM ALL DATA. IN SOME CASES EQUIPMENT, FIXTURESAND DEVICES ARE SHOWN ONLY. ASCERTAIN AND PROVIDE THE WIRING AND CONTROL STATIONSREQUIRED FOR THE PROPER FUNCTION OF BUILDING EQUIPMENT. NO EXTRA CHARGES SHALLBE ACCEPTED BY OWNER, AFTER BIDDING FOR SUCH EQUIPMENT AND LABOR.

29. EQUIPMENT LABELS AND INSTRUCTIONS REGARDING THE APPLICATION AND INSTALLATIONOF THE LISTED EQUIPMENT SHALL BE FOLLOWED TO INSURE THAT THE EQUIPMENT IS BEINGINSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S LISTING INSTRUCTIONS. THE TEMPERATURERATING OF THE EQUIPMENT TERMINATION MUST BE CORRELATED WITH THE CONDUCTOR AMPACITYTO PREVENT OVERHEATING AND PREMATURE FAILURE.

30. COORDINATE WORK WITH FIELD CONDITIONS AND OTHER TRADES AND INSTALL CONDUITAND BOXES TO CLEAR EMBEDDED DUCTS, OPENINGS AND OTHER STRUCTURAL FEATURES.

31. ALL WORK IS TO BE DONE IN ACCORDANCE WITH THE LATEST REQUIREMENTS OF ALL APPLICABLECODES AND REGULATIONS.

32. ALL LIGHTING FIXTURES ARE TO BE LOCATED AS REQUIRED ON THE JOB TO CLEAR DUCTS,PIPING, EQUIPMENT, AND/OR MECHANICAL UNITS.

33. ALL OF THE BOXES, CONDUITS, WIRES, CONTROL STATIONS, SLEEVES, INSERTS, FRAMESAND ANCHORS ARE NOT SHOWN ON THE DRAWINGS. ONLY MAJOR ITEMS ARE SHOWN. COORDINATEALL WORK AS REQUIRED FOR PROPER DEMOLITION AND INSTALLATION.

NO WIRING SHALL BE DONE PRIOR TO THE CONTRACTOR'S REVIEW OF THE PROJECT EQUIPMENTSHOP DRAWINGS. COORDINATE FIELD CONDITIONS WITH THE DESIGN DOCUMENTS. ANYDISCREPANCIES SHALL BE BROUGHT TO THE ARCHITECT/ENGINEER'S ATTENTION FOR FINALRESOLUTION. WORK THAT HAS TO BE REPLACED DUE TO LACK OF PROPER SHOP DRAWINGSCOORDINATION SHALL BE DONE AT CONTRACTOR'S EXPENSE.

NEW PANELS SHALL NOT BE INSTALLED BELOW WATER PIPES OR VENTILATION DUCTS.IF EXISTING PANELS ARE LOCATED BELOW PIPES OR DUCTS, PROVIDE DRIP PANS ABOVEEXISTING PANELS.

FURNISH AND INSTALL EQUIPMENT DISCONNECT SWITCHES IN STRICT COMPLIANCE WITHCODE REQUIREMENTS. (NOT ALL LOCAL DISCONNECT SWITCHES AREA SHOWN).

ALL OUTLETS BOXES SHALL BE PROVIDED WITH PROPER COVER PLATES.

ALL CODE VIOLATIONS ENCOUNTERED RELATING TO EXISTING SYSTEM WIRING WHICH ISOR MAY BE AFFECTED BY THE WORK TO BE INSTALLED SHALL BE IDENTIFIED AS TO TYPEOF VIOLATION, LOCATION, DESCRIPTION AND CODE-REFERENCED SECTION AS PART OF THISCONTRACT. THIS DATA SHALL BE IN TYPEWRITTEN FORM, WITH DRAWINGS IF REQUIREDFOR LOCATION AND SHALL BE GIVEN TO THE CONSTRUCTION MANAGER AND THE ENGINEER.

EXISTING SERVICES SHOULD NOT BE INTERRUPTED WITHOUT THE CONSENT OF THE BUILDINGENGINEER AND SHOULD BE DONE ONLY FOR THE DATE AND DURATION MUTUALLY AGREED UPON.

CIRCUITS ARE SIZED ASSUMING NO MORE THAN THREE CURRENT CARRYING CONDUCTORSIN A SINGLE CONDUIT. FOR CONDUITS CONTAINING MORE THAN THREE, PROVIDE APPROPRIATEDERATING OF CONDUCTORS PER PRESENT APPLICABLE CODES.

PREPARE AND SUBMIT 1/4" SCALE INSTALLATION DRAWINGS PRIOR TO ORDERING EQUIPMENTAND ROUGHING FEEDERS. LOCATE ALL ELECTRICAL EQUIPMENT, INDICATE CLEARANCESAND ROUTING OF ALL UNDERGROUND AND OVERHEAD FEEDERS.

FIRE ALARM CONTROL PANEL AND ASSOCIATED EQUIPMENT SHALL HAVE A DEDICATED BRANCHCIRCUIT BREAKER WITH RED MARKING AND SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT"IN ACCORDANCE WITH NFPA 72-1-5.2.5. PROVIDE LOCK ON DEVICE FOR CIRCUIT BREAKER.

THE FIRE ALARM CONTROL PANEL AND ASSOCIATED EQUIPMENT SHALL BE PERMANENTLYIDENTIFIED WITH THE LOCATION OF THE CIRCUIT DISCONNECTING MEANS IN ACCORDANCEWITH NFPA 72-1-5.2.5.

ALL BRANCH CIRCUITS SHALL BE PROVIDED WITH A GREEN GROUND WIRE IN ACCORDANCEWITH THE REQUIREMENTS OF NEC 517-13. 34. THE BACKBOARDS USED FOR THE TELEPHONE AND OTHER SYSTEMS SHALL BE FIRE RATED.

INSTALL THE BACKBOARDS TO THE RATING STAMP CAN BE SEEN FOR INSPECTION. DO NOTPAINT OVER STAMP.

35. PROVIDE WRITTEN RECORD OF TESTING OF THE ELECTRICAL SERVICE GROUND FAULT PROTECTIONAND STATING THAT THE SYSTEM HAS BEEN INSTALLED AND TESTED IN ACCORDANCE WITHNEC 230-95c AND 517.17c BY THE INSTALLER WITH THE FINAL CLOSEOUT DOCUMENTATION .

36. PROVIDE BONDING TO ALL INTERIOR METAL PIPING IN ACCORDANCE WITH NEC 250.104c, INCLUDING ALL MEDICAL GAS SYSTEM PIPING, DIESEL FUEL PIPING, NATURAL GASPIPES, WASTE, VENT, DRAIN AND VACUUM PIPES.

37. ALL FEEDER AND BRANCH CIRCUIT CONDUITS SHALL BE ROUTED OVERHEAD, UNLESS SPECIFICALLYNOTED ON DRAWINGS TO BE LOCATED BELOW SLAB. WHERE A FEEDER IS SPECIFIED TOBE INSTALLED BENEATH SLAB IT SHALL BE RIGID STEEL HEAVY WALL CONDUIT AND ROUTEDA MINIMUM OF 24" BELOW SLAB. IN NO CASE SHALL THE CONDUIT BE LAID IN FLOORSLAB OR WITHIN FILL BENEATH FLOOR SLAB.

FIRE RATED PLYWOOD TELEPHONE BACKBOARD

SWITCH & FUSE

CIRCUIT BREAKER

CONDUIT STUBBED DOWN

CONDUIT STUBBED UP

CONDUIT RUN EXPOSED

CONDUIT RUN IN FLOOR SLAB

CONDUIT RUN CONCEALED IN CEILING OR WALLS

FINAL EQUIPMENT CONNECTION

MOTOR CONNECTION - H.P. AS NOTED ON DRAWINGS

FUSED DISCONNECT SWITCH

NON - FUSED DISCONNECT SWITCH

JUNCTION BOX - WALL OR CEILING MOUNTED

RECEPTACLE - RATING & VOLTAGE AS INDICATED ON DRAWINGS

DUPLEX CONVENIENCE OUTLET MOUNTED 6" ABOVE COUNTER TOP

3W THREE WAY SWITCH

DESCRIPTIONSYMBOL

SYMBOL LIST

PANELBOARD

DISTRIBUTION PANELBOARD

DENOTES GROUND WIRE

JUNCTION BOX WITH FINAL EQUIPMENT CONNECTION

, JJ

TV

DENOTES NOT IN CONTRACT

DENOTES EXISTING TO BE REMOVED

DENOTES ABOVE FINISHED FLOOR

DENOTES CONDUIT

DENOTES MAIN LUGS ONLY

DENOTES GROUND FAULT INTERRUPTER

DENOTES GROUND

DENOTES WEATHERPROOF

GRD.

GFI

M.L.O.

C.

A.F.F.

R

N.I.C.

WP

DENOTES BOLTED PRESSURE SWITCHB.P.S.

A. DENOTES AMPERES

DUPLEX CONVENIENCE OUTLET (+ 18" ABOVE FINISHED FLOOR)

DOUBLE DUPLEX OUTLET (+ 18" ABOVE FINISHED FLOOR)

S

DOUBLE - COMBINATION VOICE/DATA OUTLET

COMBINATION VOICE/DATA OUTLET

MOUNTED (+54" ABOVE FINISHED FLOOR) "P" DENOTES PUBLIC PAYPHONE (+54" ABOVE FINISHED FLOOR)

TELEPHONE OUTLET (+ 18" ABOVE FINISHED FLOOR) "W" DENOTES WALL

WP

DENOTES EXISTING TO REMAINE

DENOTES EXISTING TO BE REMOVED AND RELOCATEDRR

DENOTES NEW LOCATION OF RELOCATED DEVICERE

DENOTES EXISTING DEVICE TO BE REMOVED AND REPLACEDEN WITH NEW IN SAME LOCATION

DENOTES NEW DEVICE IN EXISTING LOCATION OF REMOVED DEVICEND

SINGLE POLE SWITCH

S

MSOCCUPANCY SENSOR SWITCH - PROVIDE SENSOR SWITCH # WSD OR APPROVEDS

EQUAL. VERIFY FINISH WITH ARCHITECT.

FLUSH FLOOR MOUNTED OUTLET BOX WITH DUPLEX RECEPTACLE.

TELEVISION/MONTIOR OUTLET. PROVIDE BACKBOX WITH 1"C TO ACCESSIBLECEILING SPACE. DEVICES BY OTHERS.

Revisions

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

Des

ign

Arc

hit

ectu

re In

c.15

50 N

. No

rth

wes

t H

igh

way

, Su

ite

400

Par

k R

idg

e, Il

lino

is 6

0068

-146

3T

847

.298

.690

0 F

847

.298

.696

6

Ch

ipm

an

AS NOTED

--- -

-

Pro

fess

iona

l El e

ctric

al E

n gin

eers

DIC

KE

RS

ON

EN

GIN

EE

RIN

G, I

NC

.

8101

NO

RT

H M

ILW

AU

KE

E A

VE

NU

EN

ILE

S, I

LLIN

OIS

607

14

FA

X (

8 47

) 96

6-02

9 4T

EL

(847

) 96

6-02

9 0

NOT

FOR C

ONSTU

RCTIO

N

7/23

/201

2

H:\1

2068

\_ba

sefil

es\E

LEC

_120

68.r

vt7/

23/2

012

1:32

:03

PM

E001

-

Slo

an's

NO

TE

S, E

LEC

TR

ICA

L S

PE

CIF

ICA

ITO

NS

AN

D S

YM

BO

L LI

ST

PR

OT

OT

YP

E

DRAWING INDEXSHEET # DESCRIPTION

E001 NOTES, ELECTRICAL SPECIFICAITONS AND SYMBOL LISTE002 ELECTRICAL ONE LINE DIAGRAM AND PANEL SCHEDULEE100 FLOOR PLAN - POWER AND SPECIAL SYSTEMSE200 FLOOR PLAN - LIGHTINGFA01 FLOOR PLAN - FIRE ALARM

PANEL PANELM

HOULIHAN'S SPACE

ROOF

GRADE

60A-3P

60A-3P

RTU

1

RTU

2

MDP A

NEW METER AND C/TCABINET

NEW 400A-3P DISCONNECTFUSED AT 400A

INCOMINGSERVICE FEED

3 1/2"C. - 4 # 500 MCM

3/4"C - 1 # 1/0

2"C. - 3 # 3/0,1 # 6 GROUND,

DD DD

RT

I

RT

I

3 1/2"C. - 4 # 500 MCM

TO CODE APPROVEDGROUND

& 1 # 6 ISOLATEDGROUND

(TYPICAL OF 2)SEE NOTE # L5

3 1/2"C. - 4 # 500 MCMBONDING JUMPER ACROSSMETER, PROVIDE # 3/0

BUS

SERVICE EQUIPMENT

UNDERGROUND METALLICWATER PIPE LOCATED ON"STREET" SIDE OF WATER

1"C.-1 # 3/0

NEUTRAL BUS

GROUNDINGEQUIPMENT

STEELBUILDING

NO. 6 AWGCOPPER MINIMUM

GROUND RODCOPPER CLAD(2) 3/4"D. X 10'L.

WATER METER

(IF AVAILABLE)

G2. SERVICE GROUND MAY BE IN LAND LORD EQUIPMENT ROOM.

NOTES:

CONTRACTOR SHALL OBTAIN APPROVAL FROM LOCAL CODEAUTHORITIES BEFORE INSTALLING GROUNDING.

G1.

L1. ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF THENATIONAL ELECTRIC CODE AND ALL LOCAL CODES. COORDINATE EXACT CODE REQUIREMENTS AND LOCAL AMENDMENTS WITH LOCAL INSPECTOR PRIOR TO ANY INSTALLATION.

L2. CONTRACTOR SHALL OBTAIN AVAILABLE FAULT CURRENT RATING FROM LANDLORD/ UTILITY COMPANY AND PROVIDE PROPERPROTECTION FOR CIRCUIT BREAKERS AND ALL BRANCH PANELS.

L3. GROUND IN ACCORDANCE WITH N.E.C. AND ALL LOCAL CODES.

L4. COORDINATE EXACT LOCATION OF TIME CLOCKS AND CONTACTORSIN THE FIELD WITH OWNER'S REPRESENTATIVE.

L5. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL NEW 120VDUCT MOUNTED SMOKE DETECTORS (IN SUPPLY) IN EACH AIRHANDLING UNIT. WIRE DUCT DETECTOR TO SHUTDOWN UNIT UPONACTIVATION. INSTALL IN ACCORDANCE WITH NFPA 72 AND 90A.PROVIDE A REMOTE TEST/INDICATING STATION(RTI) WITHAUDIBLE/VISUAL ANNUNCIATION DEVICE FOR EACH DETECTOR.MOUNT RTI AS DIRECTED BY OWNER. THIS CONTRACTOR SHALLCONDUCT A SMOKE TEST ON THE HVAC UNITS WITNESSED BY THEBUILDING INSPECTOR TO VERIFY FAN SHUT-DOWN AND SIGNALACTIVATION UPON SMOKE DETECTION. (TIE INTO FIRE ALARM SYSTEMIF ON EXISTS)

L6. ALL LIGHTING AND RECEPTACLE CIRCUITS UP TO 60'-0" IN LENGTHSHALL UTILIZE #12 CONDUCTORS MINIMUM, CIRCUITS FROM 61'-0" THRU100'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM ANDFROM 101'-0" THRU 150'-0" IN LENGTH SHALL UTILIZE #8 CONDUCTORSMINIMUM, UNLESS OTHERWISE NOTED. THIS SHALL MAINTAIN VOLTAGEDROP BELOW 3%.

ONE LINE DIAGRAM NOTES:

Revisions

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

Des

ign

Arc

hit

ectu

re In

c.15

50 N

. No

rth

wes

t H

igh

way

, Su

ite

400

Par

k R

idg

e, Il

lino

is 6

0068

-146

3T

847

.298

.690

0 F

847

.298

.696

6

Ch

ipm

an

AS NOTED

--- -

-

Pro

fess

iona

l El e

ctric

al E

n gin

eers

DIC

KE

RS

ON

EN

GIN

EE

RIN

G, I

NC

.

8101

NO

RT

H M

ILW

AU

KE

E A

VE

NU

EN

ILE

S, I

LLIN

OIS

607

14

FA

X (

8 47

) 96

6-02

9 4T

EL

(847

) 96

6-02

9 0

NOT

FOR C

ONSTU

RCTIO

N

7/23

/201

2

H:\1

2068

\_ba

sefil

es\E

LEC

_120

68.r

vt7/

23/2

012

1:32

:06

PM

E002

-

Slo

an's

ELE

CT

RIC

AL

ON

E L

INE

DIA

GR

AM

AN

DP

AN

EL

SC

HE

DU

LE

PR

OT

OT

YP

E

Receptacle 4500 VA 100.00% 4500 VA

Power 180 VA 100.00% 180 VA Total Est. Demand: 67 A

Motor 196 VA 100.00% 196 VA Total Conn.: 77.5 A

Lighting 6422 VA 125.00% 8028 VA Total Est. Demand: 24126 VA

Kitchen Equipment - Non-Dwelling Unit 15450 VA 65.00% 10043 VA Total Conn. Load: 27928 VAEquipment 1180 VA 100.00% 1180 VALoad Classification Connected Load Demand Factor Estimated Demand Panel Totals

* DENOTES LOCK-OUT CLIP: ** DENOTES GFI BREAKER: *** DENOTES VIA TIMECLOCK: **** DENOTES VIA RELAY PANEL

Legend:Total Amps: 93.5 A 68.4 A 71.6 A

Total Load: 11166 VA 8208 VA 8537 VA

Phase: A B C

41 SECURITY SYSTEM * 20 A 1 200 VA 200 VA 1 20 A FIRE ALARM NAC PANEL* 42

39 PHONE BOARD* 20 A 1 360 VA 180 VA 1 20 A LIGHTING CONTROL PANEL* 40

37 OFFICE RECEPTACLES 20 A 1 720 VA 0 VA 1 20 A Spare 38

35 OFFICE RECEPTACLES 20 A 1 180 VA 0 VA 1 20 A Spare 36

33 OFFICE RECEPTACLES 20 A 1 180 VA 0 VA 1 20 A Spare 34

31 OFFICE RECEPTACLES 20 A 1 180 VA 0 VA 1 20 A Spare 32

29 ROOFTOP RECEPTACLES 20 A 1 360 VA 888 VA 1 20 A 26" ICE CREAM DIPPING CABINET (K6) 30

27 CHOCOLATE DISPLAY (K46) 20 A 1 1560... 900 VA 1 20 A 47" ICE CREAM DIPPING CABINET (K5) 28

25 WHIP CREAM DISPENSER (K2) 20 A 1 900 VA 1380... 1 20 A 91" ICE CREAM DIPPING CABINET (K4) 26

23 DRINK MIXER (K1) 20 A 1 900 VA 732 VA 1 20 A UC REFRIG (K14) 24

21 TWO DOOR REACH IN REF (K26) 20 A 1 1320... 732 VA 1 20 A UC REFRIG (K14) 22

19 BLENDER (K13) 20 A 1 2238... 1500... 1 20 A MICROWAVE (K43) 20

17 EXTERIOR SIGNAGE **** 20 A 1 1200... 600 VA 1 20 A COKE MACHINE (K47) 18

15 EM/EXIT LIGHTING * 20 A 1 80 VA 600 VA 1 20 A TRAIN TRACK DISPLAY 16

13 BOH/TLT/OFFICE/CLOSET LIGHTING **** 20 A 1 1042... 720 VA 1 20 A POS RECEPTACLES 14

11 SERVICE LINE CHANDALIERS **** 20 A 1 1200... 720 VA 1 20 A POS RECEPTACLES 12

9 SERVICE LINE LIGHTING **** 20 A 1 777 VA 720 VA 1 20 A MONITOR BOARD 10

7 SERVICE LINE DISPLAY LIGHTING **** 20 A 1 814 VA 360 VA 1 20 A SHOW WINDOWS LIGHTING 8

5 SALES DISPLAY LIGHTING **** 20 A 1 637 VA 720 VA 1 20 A SALES FLOOR RECEPTACLES 6

3 SALES/CORRIDOR LIGHTING **** 20 A 1 259 VA 540 VA 1 20 A FLOOR DISPLAY RECEPTACLES **** 4

1 SALES SOFFIT/STOREFRONT LIGHTING **** 20 A 1 592 VA 720 VA 1 20 A BOH RECEPTACLES 2

CKT Circuit Description Trip Poles

A B C A B C

Poles Trip Circuit Description CKT

PROVIDE WITH ISOLATED AND EQUIPMENT GROUND BUS.

Notes:

Enclosure: Type 1 Neutral Bus: FULL SIZED MCB Rating:Mounting: Recessed Wires: 4 Mains Rating: 225A

Ground Bus: YES Phases: 3 Mains Type: MLO

Location: Space 2 Volts: 120/208 Wye A.I.C. Rating: 10,000

Panel: A

Receptacle 4500 VA 100.00% 4500 VA

Power 180 VA 100.00% 180 VA

Motor 1196 VA 100.00% 1196 VA Total Est. Demand: 271.1 A

Lighting 6422 VA 125.00% 8028 VA Total Conn.: 315.2 A

Kitchen Equipment - Non-Dwelling Unit 49886 VA 65.00% 32426 VA Total Est. Demand: 97685 VA

HVAC 31216 VA 100.00% 31216 VA Total Conn. Load: 113540 VAEquipment 5140 VA 100.00% 5140 VALoad Classification Connected Load Demand Factor Estimated Demand Panel Totals

* DENOTES LOCK-OUT CLIP: ** DENOTES GFI BREAKER: *** DENOTES VIA TIMECLOCK: **** DENOTES VIA CONTACTOR

Legend:Total Amps: 349.2 A 310.2 A 290.8 A

Total Load: 41592 VA 36915 VA 34895 VA

Phase: A B C

41 WAFFLE CONE MAKER (K44) 20 A 1 1320... 8523... -- -- -- 42

39 WAFFLE CONE MAKER (K44) 20 A 1 1320... 8163... -- -- -- 40

37 BAG IN BOX (K38) 20 A 1 180 VA 11105... 3 200 A PANEL A 38

35 ROUND WARMER (K19) 20 A 1 600 VA 0 VA 1 20 A Spare 36

33 FUDGE SERVER (K17) 20 A 1 1000... 0 VA 1 20 A Spare 34

31 ICE MACHINE (K14) 20 A 1 1572... 0 VA 1 20 A Spare 32

29 -- -- -- 1872... 0 VA 1 2 A Spare 30

27 DISHWASHING UNIT (K25) 25 A 2 1872... 1200... -- -- -- 28

25 -- -- -- 3775... 1200... 2 20 A OVEN (K21) 26

23 SOFT SERVE (K3) 40 A 2 3775... 600 VA 1 20 A HEAT TRACE TAPE ** 24

21 -- -- -- 3775... 200 VA -- -- -- 22

19 SOFT SERVE (K3) 40 A 2 3775... 200 VA -- -- -- 20

17 FLY FAN 20 A 1 600 VA 200 VA 3 20 A WIF EVAPORATOR 18

15 TOILET DISPLAY GLASS GAS SHADER 20 A 1 600 VA 2000... -- -- -- 16

13 -- -- -- 5000... 2000... -- -- -- 14

11 -- -- -- 5000... 2000... 3 30 A WIF CONDENSING UNIT 12

9 WH-1 60 A 3 5000... 1380... 1 20 A WOMENS HAND DRYER 10

7 SF-1 20 A 1 1000... 1380... 1 20 A MENS HAND DRYER 8

5 -- -- -- 5158... 5248... -- -- -- 6

3 -- -- -- 5158... 5248... -- -- -- 4

1 RTU-2 50 A 3 5158... 5248... 3 50 A RTU-1 2

CKT Circuit Description Trip Poles

A B C A B C

Poles Trip Circuit Description CKT

PROVIDE WITH ISOLATED AND EQUIPMENT GROUND BUS

Notes:

Enclosure: Type 1 Neutral Bus: FULL SIZED MCB Rating: 400A-3PMounting: Recessed Wires: 4 Mains Rating:

Ground Bus: YES Phases: 3 Mains Type: MCB

Location: Space 2 Volts: 120/208 Wye A.I.C. Rating: 42,000 MINIMUM

Panel: MDP

PANEL SCHEDULESSCALE: NONE

1

ELECTRICAL ONE LINE DIAGRAMSCALE: NONE

2SUGGESTED SERVICE GROUNDING DIAGRAMSCALE: NONE

3

J

J

J

CP

CP

JJ

J

J

JJ

J

J

J

J

JJ

WALK-INFREEZER

-

Space

2

OFFICE

3

PREP AREA

4

SERVICE AREA

2

17

SF

1

121214 12 14

10 10

16

14

RTU

1

RTU

2

6

6

6

6

22

TVTV

WH

1

60A-3P

8

8

4

4

EF

1

EF

2

T

TT

TIE TO LIGHTING CIRCUITSERVING AREA

2

2

E1003

GFIGFI

SEE NOTE # 1

WP

41SEE NOTE # 3

SEE NOTE # 1

SEE NOTE # 4

SEE NOTE # 5

GFI

GFI

A-13e A-13f

IG

IGIG

IG IG IG

12

SEE NOTE # 6

108

SEE NOTE# 7

MDP-8,10

A-17(VIA RELAY PANEL)

A-2,4,6

SEE NOTE # 2

4 VIA RELAYPANEL)

SEE NOTE # 11(TYPICAL OF 4)

A-10

SEE NOTE # 8MDP-17

MDP-15

WP

WP

MDP-12,14,16MDP-24

MDP-18,20,22

CONDENSER UNITIN ACCESIBLECEILING SPACE

EVAPORATOR

30A-3P

30A-2P

A-16

K25

K26

K20

K1K13

K43K9

K9

K46K5K4K6

A-12,14

# 10 A-8

SEE NOTE # 10

A-29

29 29

GFIIG

GFIIG

K2

A-41

K38

K14K17K19

K47

K44K44

14IG

60A-2P

60A-2P

K3K3

10TV TV

10

VIA RELAY PANEL

SEE NOTE # 12

TIE TO CIRCUITA-5

SEE NOTE # 4

SEE NOTE # 5

TIE TO CIRCUITA-4

SEE NOTE # 13

MOTOR SCHEDULE NOTES:

M1.

M2.

M3.

'ME' DENOTES EQUIPMENT FURNISHED UNDER DIVISION 15; INSTALLED ANDWIRED UNDER DIVISION 16.

M4.

'EE' DENOTES EQUIPMENT FURNISHED, INSTALLED AND WIRED UNDERDIVISION 16.

M5.

M6.

CONTROL PANEL (INCLUDING STARTERS, ALARMS, ETC.) AND INTERLOCKCONTROL WIRING SHALL BE FURNISHED AND INSTALLED BY EQUIPMENT SUPPLIER.POWER WIRING SHALL BE PROVIDED BY THIS CONTRACTOR.

CONTRACTOR SHALL COORDINATE ALL WORK WITH ARCHITECT, GENERALCONTRACTOR, ETC. AND WORK OF ALL OTHER TRADES.

REFER TO MECHANICAL DRAWINGS FOR EXACT SIZE, LOCATION, ANDELECTRICAL REQUIREMENTS FOR ALL MOTORS AND MECHANICAL EQUIPMENT.COORDINATE WITH MECHANICAL CONTRACTOR AND PROVIDE ELECTRICALCONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM.

'MM' DENOTES EQUIPMENT FURNISHED, INSTALLED AND WIRED BY DIVISION 15.

ITEM

DIS

CO

NN

EC

T S

WIT

CH

MOTOR/EQUIPMENT SCHEDULE

VO

LTA

GE

& P

HA

SE

HP

, WA

TT

S O

R A

MP

S

MOTOREQUIPMENT

DESIGNATION LOCATION

CONDUIT,

PA

CK

AG

ED

CO

NT

RO

LLE

R

FIR

E A

LAR

M IN

TE

RC

ON

NE

CT

FA

N S

HU

TD

OW

N R

ELA

Y &

DU

CT

MO

UN

TE

D S

MO

KE

TH

ER

MO

ST

AT

DE

TE

CT

OR

IN S

UP

PLY

OV

ER

LOA

D S

WIT

CH

SIN

GLE

PO

LE T

HE

RM

AL

SOURCE

POWER

WIRE AND

CONTROL DEVICES SIZE

ST

AR

TE

R S

IZE

(B

Y E

.C.)

REMARKS

BY

E.C

.

(> 2

,000

CF

M)

(> 1

5,00

0 C

FM

)D

ET

EC

TO

R IN

RE

TU

RN

DU

CT

MO

UN

TE

D S

MO

KE

EE -- ---20A1P

-EF2

120V981PHW

TOILET EXHAUST FANEF-2

- --- -- -HW1

208V15.03PHKW

3/4"C.-2 # 12& 1 # 12 GROUND

60A3P

MDP-(1,3,5)1"C.-3 # 6& 1 # 10 GROUND

RTU2

- MM EE - EE43.0FLA

208V3PH

60A3P

RTU1

ME -WP

ROOF TOP UNITRTU-1 ROOF

MDP-(2,4,6)1"C - 3 # 6& 1 # 10 GROUND

- MM EE - EE43.0FLA

208V3PH

60A3PME -WP

ROOF TOP UNITRTU-2 ROOF

MDP-(1,3,5)

ACCESIBLECEILINGSPACE

1"C - 3 # 6& 1 # 10 GROUND

HOT WATER HEATERHW-1

KITCHEN

EE -- ---20A1P

-EF1

120V981PHW

TOILET EXHAUST FANEF-1

REFER TO SHEET # E2003/4"C.-2 # 12& 1 # 12 GROUND

ACCESIBLECEILINGSPACE

REFER TO SHEET # E200

EE -- ---20A1P

-SF1

120V1/21PHHP

SUPPLY FANSF-1

MDP-73/4"C.-2 # 12

ACCESIBLECEILINGSPACE & 1 # 12 GROUND

SEE NOTE # M5

SEE NOTE # M5

PANEL A

DISTRIBUTION PANEL MDP LIGHTING CONTROL PANEL

TELEPHONE FIRERATED PLYWOODBACKBOARD 2'H X 4'W X 3/4"DMOUNT 1' BELOW FINISHED CEILING

+72" AFF

IG

A-39

+48"AFF

31 3335

3737 37

FINAL CONNECTION TOFIRE ALARM NACPANEL +48" AFF

37

ELECTRICAL CONTRACTOR SHALLCOORDINATE ALL LOCATIONS ANDMOUNTING HEIGHTS WITH ARCHTECTURALDRAWINGS AND OWNER'S REPRESENTATIVEPRIOR TO ROUGH IN OF EQUIPMENT.

A-42

IGIG

IG

A-37

A-31,33,35

A-40FINAL EQUIPMENTCONECTION FORLIGHTING CONTROLPANEL

Revisions

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

Des

ign

Arc

hit

ectu

re In

c.15

50 N

. No

rth

wes

t H

igh

way

, Su

ite

400

Par

k R

idg

e, Il

lino

is 6

0068

-146

3T

847

.298

.690

0 F

847

.298

.696

6

Ch

ipm

an

AS NOTED

--- -

-

Pro

fess

iona

l El e

ctric

al E

n gin

eers

DIC

KE

RS

ON

EN

GIN

EE

RIN

G, I

NC

.

8101

NO

RT

H M

ILW

AU

KE

E A

VE

NU

EN

ILE

S, I

LLIN

OIS

607

14

FA

X (

8 47

) 96

6-02

9 4T

EL

(847

) 96

6-02

9 0

NOT

FOR C

ONSTU

RCTIO

N

7/23

/201

2

H:\1

2068

\_ba

sefil

es\E

LEC

_120

68.r

vt7/

23/2

012

1:32

:11

PM

E100

-

Slo

an's

FLO

OR

PLA

N -

PO

WE

R A

ND

SP

EC

IAL

SY

ST

EM

S

PR

OT

OT

YP

E

1/4" = 1'-0"1 FLOOR PLAN - POWER AND SPECIAL SYSTEMS

MOTOR/EQUIPMENT SCHEDULESCALE: NONE

6

POWER PLAN PART PLANSCALE: NONE

3KITCHEN EQUIPMENT SCHEDULE AND NOTESSCALE: NONE

2

POWER PLAN NOTESSCALE: NONE

6

1. SHOW WINDOW RECPETACLE. RECEPTACLE SHALL BE MOUNTED NO HIGHER THAN 18" ABOVE2. ELECTRICAL CONTRACTOR SHALL PROVIDE FINAL CONNECTION TO SOFFIT AND SHELF MOUNTED MODEL

TRAIN DISPLAY. VERIFY EXACT ELECTRICAL REQUIREMENTS OF EQUIPMENT WITH OWNER'S VENDOR.COORDINATE LOCATION WITH OWNER'S REPRESENTATIVE PRIOR TO ROUGH IN.

3. SECURITY SYSTEM. COORDINATE ELECTRICAL REQUIREMENTS WITH OWNER'S SECURITY SYSTEM VENDOR.4. VERIFY EXACT LOCATION WITH OWNER'S REPRESENTATIVE PRIOR TO ROUGH IN.5. ALL CONDUIT ROUTED IN FLOOR SLAB SHALL BE 3/4" RIGID GALVANIZED STEEL CONDUIT IN SLAB, GRADE, OR

ROUTED IN CEILING SPACE OF FLOOR BELOW WHERE FLOOR EXISTS.

6. FINAL CONNECTION TO ELECTRIC PRIVACY GLASS WINDOW. PROVIDE A RED MUSHROOM BUTTON SWITCH FORCONTROL OF ELECTRIC PRIVACY GLASS WINDOW. VERIFY EXACT ELECTRICAL AND SWITCHINGREQUIREMENTS WITH OWNER’S VENDOR. COORDINATE SWITCH STYLE AND LOCATION WITH OWNER’SREPRESENTATIVE.

7. PROVIDE FINAL CONNECTION TO HAND DRYER. VERIFY ALL REQUIREMENTS WITH EQUIPMENT VENDOR PRIORTO ROUGH-IN. PROVIDE LABEL WITH CIRCUIT NUMBER FOR HAIR DRYERS. PROVIDE CIRCUIT BREAKER WITHPAD LOCK OUT CAPABILITIES.

8. PROVIDE FINAL CONNECTION TO FLY FAN. VERIFY ELECTRICAL REQUIREMENTS WITH OWNER'S VENDOR.9. CONTRACTOR SHALL LAYOUT BRANCH CIRCUIT WIRING AND ARRANGEMENT OF HOMERUNS FOR MAXIMUM

EFFICIENCY. INCREASE WIRE SIZE IF VOLTAGE DROP EXCEEDS 2% OR 60 FEET IN LENGTH.

10. PROVIDE FINAL CONNECTION TO SIGNAGE. COORDINATE LOCATION AND REQUIREMENTS WITH SIGNCONTRACTOR. PROVIDE LOCAL DISCONNECT SWITCH MOUNTED IN AN INCONSPICUOUS LOCATION. EACHSIGN CIRCUIT SHALL HAVE SEPARATE NEUTRAL AND SEPARATE EQUIPMENT GROUND CONDUCTORS. SIGNAGETO BE FURNISHED AND INSTALLED BY OWNER’S VENDOR, WITH FINAL CONNECTION BY ELECTRICALCONTRACTOR. VERIFY NUMBER AND LOCATION OF SIGNS WITH OWNER'S REPRESENTATIVE PRIOR TOROUGH-IN.

11. CONTRACTOR SHALL REFER TO FOOD SERVICE DRAWINGS FOR EXACT LOCATIONS AND ADDITIONALELECTRICAL REQUIREMENTS. PROVIDE J-BOXES, RECEPTACLES, CONNECTIONS CONDUITS (TO INCLUDE SODAAND LIQUOR DISPENSING SYSTEMS),WIRE, INTERLOCKS, CONTROLS, ETC., AS REQUIRED BY THE FOODSERVICE EQUIPMENT SUPPLIER.

12. PROVIDE FINAL CONNECTION TO CABINET LIGHTING. VERIFY CONNECTION REQUIREMENTS WITH OWNER'SCABINET VENDOR.

13. FINAL CONNECTION TO DISPLAY CASE LIGHTING. PROVIDE NORA LIGHTING # NUTP4-16LED OR APPROVEDEQUAL LED ROPE LIGHT. VERIFY EXACT CONTROL REQUIREMENTS, LOCATION AND LENGTHS OF FIXTUREWITHIN DISPLAY CABINETS WITH OWNER’S REPRESENTATIVE AND ARCHITECT. PROVIDE ALL APPURTENANCESFOR A COMPLETE AND OPERABLE INSTALLATION OF FIXTURE.

ITEM # DESCRIPTION VOLTAGE PHASEEQUIPMENT

LOAD FLA

GFCIPROTECTION

TYPE CONDUIT & WIRE CIRCUIT REMARKSK1 DRINK MIXER 120 V 1 900 W 7.5 A RECEPTACLE 3/4"C - 2 # 12 & 1 # 12 GROUND A-23K2 WHIP CREAM DISPENSER 120 V 1 950 W 8 A RECEPTACLE 3/4"C - 2 # 12 & 1 # 12 GROUND A-25K3 SOFT SERVE ICE CREAM MACHINE 208 V 1 7550 W 36.3 A 1"C - 2 # 8 & 1 # 10 GROUND MDP-(19,21),(23,25)K4 91" ICE CREAM DIPPING CABINET 120 V 1 1380 W 11.5 A BREAKER 3/4"C - 2 # 12 & 1 # 12 GROUND A-26K5 47" ICE CREAM DIPPING CABINET 120 V 1 900 W 7.5 A BREAKER 3/4"C - 2 # 12 & 1 # 12 GROUND A-28K6 26" ICE CREAM DIPPING CABINET 120 V 1 888 W 7.4 A BREAKER 3/4"C - 2 # 12 & 1 # 12 GROUND A-30K9 U/C REFRIGERATOR 120 V 1 732 W 6.1 A BREAKER 3/4"C - 2 # 12 & 1 # 12 GROUND A-22,24K13 BLENDER 120 V 1 2238 W 18.3 A BREAKER 3/4"C - 2 # 12 & 1 # 12 GROUND A-19K14 ICE MAKER 120 V 1 1572 W 13.1 A RECEPTACLE 3/4"C - 2 # 12 & 1 # 12 GROUND MDP-31K17 FUDGE SERVER 120 V 1 1000 W 8.3 A RECEPTACLE 3/4"C - 2 # 12 & 1 # 12 GROUND A-28K19 ROUND WARMER 120 V 1 1500 W 12.5 A RECEPTACLE 3/4"C - 2 # 12 & 1 # 12 GROUND A-26K20 COUNTER TOP OVEN 208 V 1 2400 W 11.5 A 3/4"C - 2 # 10 & 1 # 10 GROUND MDP-(26,28) PROVIDE NEMA 6-15R

RECEPTACLE.

K25 DISHWASHER 208 V 1 3744 W 18 A 3/4"C - 2 # 10 & 1 # 10 GROUND MDP-(27,29)K26 TWO DOOR REACH IN FRIDGE 120 V 1 1320 W 11 A BREAKER 3/4"C - 2 # 12 & 1 # 12 GROUND A-21K38 BAG IN BOX 120 V 1 120 W 1.5 A RECEPTACLE 3/4"C - 2 # 12 & 1 # 12 GROUND MDP-37K43 MICROWAVE 120 V 1 1500 W 13 A RECEPTACLE 3/4"C - 2 # 12 & 1 # 12 GROUND A-20K44 WAFFLE CONE MAKER 120 V 1 1320 W 11 A RECEPTACLE 3/4"C - 2 # 12 & 1 # 12 GROUND MDP-39,41K46 CHOCOLATE DISPLAY UNIT 120 V 1 1560 W 13 A BREAKER 3/4"C - 2 # 12 & 1 # 12 GROUND A-27K47 FREE STYLE COKE MACHINE 120 V 1 600 W 5 A BREAKER 3/4"C - 2 # 12 & 1 # 12 GROUND A-18

PANELS S

LCP

PROVIDE 3/4"C. WITH1 - CAT 5 CABLE FROM PANELLCP TO REMOTE SWITCH

INCOMING LIGHTINGCIRCUITS SERVED BYLIGHTING CONTROL PANEL

SEE NOTE # 6

SEE NOTE # 1

TO LIGHTING FIXTURESSEE NOTE # 2

PROVIDE 3/4"C. WITH1 - CAT 5 CABLE

11 1

111 1

111 1

555555555

1

1

1

1

9

9

333

3

1

3

3

3

13b

13a

13a

13a13a

13

13c

13d

7 7 7 7 7 7 7 7 7 7

7

7 7 7 7 7 7 7 7 7 7713

13

13 13

1515

15

13

1515

E2

B1 B1

G1

EMEM

EM

A1A1

A1 A1

A1

A1A1

A1

G1

B1B1

C1

E1

EM

A2 A2 A2 A2 A2 A2 A2 A2A2

EMEM

A1A1 A1 A1 A1

A1

A1

EMEM

A1

A1 A1

A1

A1

A1

A1 A1

A1

A1

A1

A1

A1A1A1A1A1A1A1A1A1

A1 A1

A1

A1 A1 A1 A1 A1

A1 A1

EM

G1

13

G1

15

D2

D2

13f

13e

A1

fe

3Wa

a

d

VIA RELAY PANEL

A-1,3,5VIA RELAY PANEL

c

4W

3W

A-13(13a VIA RELAY PANEL)

SEE NOTE # 1(TYPICAL)

SEE NOTE # 2

SEE NOTE # 2

A-15

bMSMS

MSMS

SEE NOTE# 4

SEE NOTE # 5A2 A2 A2

5 5 5

D211

A-7,9,11

SEE NOTE# 9

A1

D2A1

D2A1

D2A1

D2A1

D2A1

D2A1

D2A1

D2A1

D2A1

D2A1

D2A1

D2A1

D2A1

D2A1

D2A1

D2A1

D2A1

D2A1

D29

11 9 11 9 11 9 11 9 11 9 11 9 11 9 11 9 11 9 11 9 11 9 11 9 11 9 11 9 11 9 11 9 11 9 11 9 11

A1A1 A1 A1

13e13e 13f

13f

Revisions

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

Des

ign

Arc

hit

ectu

re In

c.15

50 N

. No

rth

wes

t H

igh

way

, Su

ite

400

Par

k R

idg

e, Il

lino

is 6

0068

-146

3T

847

.298

.690

0 F

847

.298

.696

6

Ch

ipm

an

AS NOTED

--- -

-

Pro

fess

iona

l El e

ctric

al E

n gin

eers

DIC

KE

RS

ON

EN

GIN

EE

RIN

G, I

NC

.

8101

NO

RT

H M

ILW

AU

KE

E A

VE

NU

EN

ILE

S, I

LLIN

OIS

607

14

FA

X (

8 47

) 96

6-02

9 4T

EL

(847

) 96

6-02

9 0

NOT

FOR C

ONSTU

RCTIO

N

7/23

/201

2

H:\1

2068

\_ba

sefil

es\E

LEC

_120

68.r

vt7/

23/2

012

1:32

:29

PM

E200

-

Slo

an's

FLO

OR

PLA

N -

LIG

HT

ING

PR

OT

OT

YP

E

1/4" = 1'-0"1 FLOOR PLAN - LIGHTING

MARK Description MANUFACTURER MODELLAMP TOTAL

WATTAGE VOLTAGE MOUNTING REMARKSQUANTITY TYPEA1 CAN LIGHT LIGHTOLIER 303MRE/313WHX 1 LED 15 W 120 V RECESSED PROVIDE WITH LIGHTING SCIENCE #

DFN-16-W27-V2 LAMP

A2 DIRECTIONAL CANLIGHT

LIGHTOLIER 303MRE/313WHX 1 LED 15 W 120 V RECESSED PROVIDE WITH LIGHTING SCIENCE #DFN-16-W27-V2 LAMP

B1 2' X4' PRISMATICACRYLIC TROFFER

LIGHTOLIER XP2GVA332120H3 3 F032/835XPS/ECO 87 W 120 V RECESSED

C1 2' X2' PRISMATICACRYLIC TROFFER

LIGHTOLIER XP2GVA26U120H1 2 FBO/835XP/6/ECO 59 W 120 V RECESSED

D2 CHANDELIER TBA TBA TBAE1 FLOURESCENT

STRIP LIGHTLIGHTOLIER SW4S148SLUNVH1 1 F032/835XPS/ECO 32 W 120 V PENDANT PROVIDE WITH AH5CSP

E2 FLOURESCENTSTRIP LIGHT

TBA TBA 1 F032/835XPS/ECO 32 W 120 V SURFACE PROVIDED BY EQUIPMENT VENDOR

EM EMERGENCY LIGHT LIGHTOLIER RD-W 2 INCLUDED 15 W 120 V WALL PROVIDE WITH INTEGRAL TESTSWITCH

G1 EXIT SIGN LIGHTOLIER EX-1-G-X-RC-M-N - LED 5 W 120 V SURFACE PROVIDE WITH INTEGRAL TESTSWITCH

LIGHTING ZONE CONTROL SCHEDULESCALE: NONE

5 LIGHTING RELAY PANEL AND NOTESSCALE: NONE

4

LIGHTING PLAN NOTESSCALE: NONE

2LIGHTING FIXTURE SCHEDULESCALE: NONE

3

1. WIRE EXIT AND EMERGENCY LIGHTING AHEAD OF LOCAL SWITCHING ANDRELAY PANEL.

2. WIRE EXHAUST FAN SERVING ROOM TO THE SWITCHED SIDE OF THE LOCALLIGHTING CIRCUIT SERVING ROOM.

3. CONTRACTOR SHALL LAYOUT BRANCH CIRCUIT WIRING AND ARRANGEMENTOF HOMERUNS FOR MAXIMUM EFFICIENCY. INCREASE WIRE SIZE IFVOLTAGE DROP EXCEEDS 2% OR 60 FEET IN LENGTH.

4. LIGHTING RELAY PANEL SWITCH BANK. COORDINATE EXACT LOCATION OFSWITCH BANK WITH ARCHTECT OR OWNER'S REPRESENTATIVE PRIOR TOROUGH IN. SEE DETAIL THIS SHEET FOR ADDITIONAL INFORMATION.

5. PROVIDE SEALS AND EXPANSION COUPLING ON ALL CONDUITS ENTERINGOR LEAVING WALK-IN FREEZER/COOLER UNIT.

6. EMERGENCY LIGHTS AND EXIT SIGNS ARE SHOWN ARE CONSIDERED AMINIMUM. COORDINATE WITH AUTHORITY HAVING JURISDICTION IFADDITIONAL FIXTURES ARE REQUIRED.

7. COORDINATE ALL LIGHTING LOCATIONS AND MOUNTING HEIGHTS WITHARCHITECTURAL DRAWINGS PRIOR TO ROUGH IN.

8. FIXTURES RECESSED IN “T-BAR” CEILING SHALL BE SUPPORTEDINDEPENDENTLY OF CEILING SYSTEM, WITH TOW # 12 HANGER WIRES UPTOSTRUCTURE. SECURE HANGER WIRES TO CORNERS OF FIXTURE. CLIPFIXTURE TO GRID ON TWO SIDES WITH FACTORY-FURNISHED CLIPS. FINALCONNECTIONS TO FIXTURE SHALL BE MADE WITH FLEXIBLE U.L. APPROVEDASSEMBLY.

9. OVERRIDE SWITCH FOR BATHROOM PRIVACY GLASS. VERIFY EXACTLOCATION OF SWITCH IN OFFICE WITH OWNER'S REPRESENTATIVE.

LIGHTING FIXTURE SCHEDULE NOTES1. CONTRACTOR SHALL PROVIDE ALL LAMPS. ALL FLUORESCENT LAMPS SHALL BE BY

THE SAME LAMP MANUFACTURER IN ORDER TO MATCH COLOR PHOSPHORS. ALLFLUORESCENT LAMPS SHALL BE OF THE LOW MERCURY CONTENT TYPE.

2. CONTRACTOR SHALL PROVIDE ALL NECESSARY MOUNTING HARDWARE, TRIM RINGS,ETC. FOR THE TYPE OF CEILING SPECIFIED. COORDINATE WITH THEARCHITECTURAL DRAWINGS.

3. CONTRACTOR SHALL VERIFY THICKNESS OF CEILING SYSTEMS AND PROVIDEEXTENSIONS AS REQUIRED FOR ALL DOWNLIGHTS.

4. ALL VOLTAGES TO BE VERIFIED AND COORDINATED BY THE CONTRACTOR.5. FINISHES, MOUNTING HEIGHTS, AND INSTALLATION DETAILS SHALL BE VERIFIED

WITH THE ARCHITECT, PRIOR TO ORDERING OF FIXTURES.

6. ALL ADJUSTABLE FIXTURES WILL BE FOCUSED BY THE ELECTRICAL CONTRACTORUNDER OBSERVATION OF THE OWNER'S REPRESENTATIVE.

7. EXACT LOCATION FOR EMERGENCY FIXTURES SHALL BE COORDINATED IN FIELD SOAS NOT TO BE OBSTRUCTED FROM VIEW BY PIPES, DUCTS, ETC. BATTERY LIGHTHEADS SHALL BE AIMED TO PROVIDE MAXIMUM ILLUMINATION.

8. ALL FLUORESCENT LIGHTING FIXTURES WITH DOUBLE ENDED LAMPS SHALL BEPROVIDED WITH BALLAST DISCONNECT SWITCHES IN COMPLIANCE WITH 2008 NEC410.73(G). ALL BALLASTS SHALL BE LESS THAN 10% THD, HIGH EFFICIENCYELECTRONIC TYPE WITH NORMAL BALLAST FACTOR.

9. ALL LIGHT FIXTURES SHALL BE LABELED BY MANUFACTURER TO MAXIMUM WATTAGELISTED IN LIGHTING FIXTURE SCHEDULE. MANUFACTURER SHALL PROVIDE REDUCEWATTAGE LABEL FOR LIGHT FIXTURE AS REQUIRED TO COMPLY WITH ENERGY CODEREQUIREMENTS.

10. ALL EMERGENCY LIGHTS SHALL BE UL924 COMPLIANT AND HAVE MINIMUM OF 90MINUTE BATTERY BACKUP.

ZONEZONE

DESCRIPTIONCIRCUITS

CONTROLLED REMARKS1 BACK OF THE

HOUSEA-13a PROGRAM FOR MANUAL 2HR OVERRIDE OUTSIDE

OF SCHEDULED OPERATIONAL HOURS.

2 SALES FLOORLIGHTING

A-1,3 PROGRAM FOR MANUAL 2HR OVERRIDE OUTSIDEOF SCHEDULED OPERATIONAL HOURS.

3 SERVICE LINELIGHTING

A-9 PROGRAM FOR MANUAL 2HR OVERRIDE OUTSIDEOF SCHEDULED OPERATIONAL HOURS.

4 SALESDECORATIVELIGHTING

A-5,7,11 PROGRAM FOR MANUAL 2HR OVERRIDE OUTSIDEOF SCHEDULED OPERATIONAL HOURS.

5 FLOORRECEPTACLES

A-4

6 BATHROOMPRIVACYGLASS

MDP-6

LIGHTING CONTROL PANEL NOTES1. ELECTRICAL CONTRACTOR SHALL PROVIDE A LC&D LIGHTING

CONTROL PANEL # GR1416 LT INT NCL DTCMOD WITH GR1416 LTENC FM NE1 ENCLOSURE OR APPROVED EQUAL.

2. ELECTRICAL CONTRACTOR SHALL PROVIDE A SIX ZONE CHELSEADIGITAL SWITCH BY LC&D. SWITCH SHALL BE ENGRAVED PEROWNER'S REQUIREMENTS. PROVIDE APPROVED EQUAL IFALTERNATE LIGHTING CONTROL PANEL SYSTEM IS PROVIDED.PROVIDE ALL COMPONENTS AS REQUIRED FOR A COMPLETE ANDOPERABLE INSTALLATION.

3. COORDINATE PROGRAMING REQUIREMENTS WITH OWNER'SVENDOR AND REPRESENTATIVE.

4. CONTACT LC&D AT 1-800-345-4448 FOR ADDITIONAL INFORMATION.5. LIGHTING CONTROL PANEL SHALL BE WIRED TO CIRCUIT A-40.6. ELECTRICAL CONTRACTOR SHALL PROVIDE A SINGLE ZONE

CHELSEA DIGITAL SWITCH BY LC&D FOR BATHROOM PRIVACYGLASS. SWITCH SHALL BE ENGRAVED PER OWNER'SREQUIREMENTS. PROVIDE APPROVED EQUAL IF ALTERNATELIGHTING CONTROL PANEL SYSTEM IS PROVIDED. PROVIDE ALLCOMPONENTS AS REQUIRED FOR A COMPLETE AND OPERABLEINSTALLATION.

AV S

VV

AV

AVS

V

FA1.

FA2.

FA3.

FA4.

FA5.

WORK SHALL INCLUDE A COMPLETE NFPA72, IBCC, AND ADA COMPLIANT FIRE ALARM SYSTEM.

FIRE ALARM CONTRACTOR SHALL PROVIDE A COMPLETE AND OPERABLE FIRE ALARM SYSTEM,APPROVED BY THE LOCAL FIRE PREVENTION BUREAU HAVE JURISDICTION OVER THIS PROJECT.SYSTEM SHALL BE HARD WIRED AND COMPLETELY ADDRESSABLE. SYSTEM SHALL BE DESIGN BUILDWITH THE OWNER'S VENDOR IN CONJUNCTION WITH THE ELECTRICAL CONTRACTOR. COORDINATEOWNER'S VENDOR WITH OWNER'S REPRESENTATIVE AT TIME OF BIDDING.

WALL MOUNTED BOXES TO BE FLUSH 4" SQUARE, WITH EXPANSION RING. UNLESS SPECIFICALLYCALLED OUT OTHERWISE ON THE PLAN DRAWINGS.

VERIFY ALL SYSTEM REQUIREMENTS WITH VENDOR PRIOR TO INSTALLATION AND COMPLY WITH ALLTHIER REQUIREMENTS.

INSTALLATION SHALL MEET THE APPROVAL OF THE THE LOCAL FIRE INSPECTOR, BUILDING ANDELECTRICAL DEPARTMENT. SUBMIT COMPLETE SHOP DRAWINGS INCLUDING DEVICE LOCATIONS,POINT TO POINT WIRING DIAGRAMS, BATTERY CALCULATIONS, VOLTAGE DROP CALCULATION, FIREALARM CIRCUIT CALCULATION AND EQUIPMENT CUTS TO CITY FIRE DEPARTMENT AND COMPLYWITH THEIR REQUIREMENTS.

FA6. COORDINATE EXACT LOCATION OF FIRE ALARM PULL STATION WITH ARCHITECT, PULL STATIONSSHALL BE MOUNTED WITHIN 5' OF AN EXITING DOOR.

SD

FIRE ALARM SYMBOL LISTSYMBOL DESCRIPTION

FIRE ALARM PULL STATION MOUNTED AT + 48" A.F.F. TO TOP OF DEVICE

COMBINATION FIRE ALARM AUDIBLE DEVICE/ADA APPROVED VISUALDEVICE MOUNTED AT + 80" A.F.F. TO CENTER OR 6" BELOW CEILING

S

AVWHICHEVER IS LOWER. "CLG" DENOTES CEILING MOUNTED DEVICE.

SMOKE DETECTOR

VFIRE ALARM ADA APPROVED VISUAL DEVICE MOUNTED AT + 80"A.F.F. TO CENTER OR 6" BELOW CEILING WHICHEVER IS LOWER."CLG" DENOTES CEILING MOUNTED DEVICE.CLG

CLG

DD DENOTES DUCT DETECTOR

SD

TENANT SPACE

ROOF

LANDLORD SPACE

NACSEE NOTE # 2

AV

SEE NOTE # 2

DD UNIT

TYPICALROOF TOP

J

V

RTI

SEE DRAWINGSHEET # E100

LANDLORDFACP

SEE NOTE # 2

AV

SEE NOTE # 2

S

SEE NOTE # 2

V

4.

3.

2.

1.

FIRE ALARM RISER NOTES:

SUBMIT FIRE ALARM SYSTEM DRAWINGS TO THE MALL AND LOCAL AHJ FORAPPROVAL AND COMPLY WITH ALL THEIR REQUIREMENTS.

ALL FIRE ALARM WIRING SHALL BE IN CONDUIT (3/4" MINIMUM). FIRE CABLE MAYBEUTILIZED IF PERMITTED BY MALL AND LOCAL CODE.

EXTEND WIRING TO ADDITIONAL DEVICES, REFER TO PLAN DRAWINGS FOREXACT LOCATION & QUANTITY.

MODIFY EXISTING LANDLORD SYSTEM AS REQUIRED TO ACCOMMODATE NEWFIRE ALARM SYSTEM.

WALK-INFREEZER

-

Space

2OFFICE

3

PREP AREA

4

SERVICE AREA

2

NA

C

DD RTI

DD RTI

Revisions

Date

Checked By

Sheet No.

Job No.

Drawn By

Scale

Des

ign

Arc

hit

ectu

re In

c.15

50 N

. No

rth

wes

t H

igh

way

, Su

ite

400

Par

k R

idg

e, Il

lino

is 6

0068

-146

3T

847

.298

.690

0 F

847

.298

.696

6

Ch

ipm

an

AS NOTED

--- -

-

Pro

fess

iona

l El e

ctric

al E

n gin

eers

DIC

KE

RS

ON

EN

GIN

EE

RIN

G, I

NC

.

8101

NO

RT

H M

ILW

AU

KE

E A

VE

NU

EN

ILE

S, I

LLIN

OIS

607

14

FA

X (

8 47

) 96

6-02

9 4T

EL

(847

) 96

6-02

9 0

NOT

FOR C

ONSTU

RCTIO

N

7/23

/201

2

H:\1

2068

\_ba

sefil

es\E

LEC

_120

68.r

vt7/

23/2

012

1:32

:38

PM

FA01

-

Slo

an's

FLO

OR

PLA

N -

FIR

E A

LAR

M

PR

OT

OT

YP

E

1/4" = 1'-0"1 FLOOR PLAN - FIRE ALARM

FIRE ALARM SYMBOL LISTSCALE: NONE

4 FIRE ALARM RISER AND NOTESSCALE: NONE

2

FIRE ALARM NOTESSCALE: NONE

3

Midwest Cabinet Company, Inc.0A

HWH

FRIG. PREP TABLE

LOCKERS

HOT WATERHEATER ABOVE

RACK

B.B.

57 SF

MEN'S ROOM6

57 SF

WOMEN'S ROOM5

79 SF

WALK-IN FREEZER7

B A

1

2

Midwest Cabinet Company, Inc.1

Midwest Cabinet Company, Inc.2

Midwest Cabinet Company, Inc.2A

Midwest Cabinet Company, Inc.2B

Midwest Cabinet Company, Inc.2C

Midwest Cabinet Company, Inc.2D

Midwest Cabinet Company, Inc.2E

Midwest Cabinet Company, Inc.2F

Midwest Cabinet Company, Inc.2G

Midwest Cabinet Company, Inc.2H

Midwest Cabinet Company, Inc.2J

Midwest Cabinet Company, Inc.2K

Midwest Cabinet Company, Inc.2L

Midwest Cabinet Company, Inc.3

Midwest Cabinet Company, Inc.3A

Midwest Cabinet Company, Inc.3B

Midwest Cabinet Company, Inc.3C

Midwest Cabinet Company, Inc.3D

Midwest Cabinet Company, Inc.4

Midwest Cabinet Company, Inc.4A

Midwest Cabinet Company, Inc.5

Midwest Cabinet Company, Inc.6

Midwest Cabinet Company, Inc.6A

Midwest Cabinet Company, Inc.6B

Midwest Cabinet Company, Inc.6C

Midwest Cabinet Company, Inc.7

Midwest Cabinet Company, Inc.8

1212

CROWN MOLDING:

RIGID POLYURETHANE MILLWORK - PROFILE ED-270463

ACANTHUS LEAF WITH BEAD AND BARREL CROWN MOLDING

STAIN TO MATCH PANEL MOLDING

PROVIDE 16 EA @ 8' LONG

REVISED

Midwest Cabinet Company, Inc.

1674 Industrial AvenueOttawa, Kansas 66067Phone: (785)242-8181Fax: (785)242-8183www.midwestcabinet.com 9

SCALE: SEE TAGS

ITEM #: 9DRAWN BY: GK

SHEET

CROWN MOLDSLOAN'S-

-

W.O. #: 76880DATE:

1 - 1 / 2 " = 1 ' - 0 "8

CROWN PROFILEA