JH/JHI - Masonry Joist Hangers
PRODUCT DESCRIPTION
The JH/JHI is the traditional timber - masonry hanger range. The higher side flanges help resist rotation while the wider masonry top flange spreads the loading over a greater surface area.
ADVANTAGES
Higher side flanges help resist rotation while the wider masonry top flange spreads the loading over a greater surface area.
MATERIAL
1.5mm (39 to 100mm wide) - galvanised mild steel - Z6002.5mm (105 to 198mm wide) - galvanised mild steel - Z600
•
••
JH/JHI JHR/JHIR
JH / JHR for Trusses & Solid Timber joists JHI / JHIR for Open Web JHI / JHIR for I-Joists
JHI Performance - I-Joist
Product Code
DimensionsFixings(3.75 x 30mm)
Safe Working Loads (kN) Characteristic Capacity of Hanger (kN)
UpliftShortTerm
Masonry Crushing Strength
Uplift
Masonry Crushing Strength
W H B Joist2.8 N/mm2 3.5 N/mm2 7.0 N/mm2 2.8 N/mm2 3.5 N/mm2 7.0 N/mm2
All widths All widths 39 to100mm wide
105 to 198mm wide All widths All widths 39 to
100mm wide105 to
198mm wideJHI-46-195 46 195 64 2 1.0 6.0 7.54 9.1 7.54 2.0 10.94 13.68 15.99 13.68
JHI-46-225 46 225 64 2 1.0 6.0 7.54 9.1 7.54 2.0 10.94 13.68 15.99 13.68
JHI-46-240 46 240 64 2 1.0 6.0 7.54 9.1 7.54 2.0 10.94 13.68 15.99 13.68
JHI-46-300 46 300 64 2 1.0 6.0 7.54 9.1 7.54 2.0 10.94 13.68 15.99 13.68
JHI-46-350 46 350 64 2 1.0 6.0 7.54 9.1 7.54 2.0 10.94 13.68 15.99 13.68
JHI-46-400 46 400 64 2 1.0 6.0 7.54 9.1 7.54 2.0 10.94 13.68 15.99 13.68
JHI-46-450 46 450 64 2 1.0 6.0 7.54 9.1 7.54 2.0 10.94 13.68 15.99 13.68
Hangers shown above are for 45mm joists, JHIs are available in widths of 39, 46, 50, 52, 61, 65, 72, 75, 78, 92, 97, 100, 105, 122, 130, 138, 150, 183 and 198mm.Standard return sizes available 100, 115, 125, 140 & 215mm.
JHI Performance - Open Web Joist
Product Code
DimensionsFixings(3.75 x 30mm)
Safe Working Loads (kN) Characteristic Capacity of Hanger (kN)
UpliftShortTerm
Masonry Crushing Strength
Uplift
Masonry Crushing Strength
W H B Joist2.8 N/mm2 3.5 N/mm2 7.0 N/mm2 2.8 N/mm2 3.5 N/mm2 7.0 N/mm2
All widths All widths 39 to 100mm wide
125 to 198mm wide All widths All widths 39 to
100mm wide125 to
198mm wideJHI-50-195 50 195 64 2 1.0 6.0 7.54 9.1 7.54 2.0 10.94 13.68 15.99 13.68
JHI-50-225 50 225 64 2 1.0 6.0 7.54 9.1 7.54 2.0 10.94 13.68 15.99 13.68
JHI-50-240 50 240 64 2 1.0 6.0 7.54 9.1 7.54 2.0 10.94 13.68 15.99 13.68
JHI-50-250 50 250 64 2 1.0 6.0 7.54 9.1 7.54 2.0 10.94 13.68 15.99 13.68
JHI-50-300 50 300 64 2 1.0 6.0 7.54 9.1 7.54 2.0 10.94 13.68 15.99 13.68
JHI-50-350 50 350 64 2 1.0 6.0 7.54 9.1 7.54 2.0 10.94 13.68 15.99 13.68
JHI-50-400 50 400 64 2 1.0 6.0 7.54 9.1 7.54 2.0 10.94 13.68 15.99 13.68JHI-50-450 50 450 64 2 1.0 6.0 7.54 9.1 7.54 2.0 10.94 13.68 15.99 13.68
Hangers shown above are for 47mm joists, JHIs are available in widths of 39, 46, 50, 75, 100, 125, 150 and 198mm.Standard return sizes available 100, 115, 125, 140 & 215mm.
CE marked - Tested in accordance with EN846-8
Makes a major contribution to compliance with air leakage
H
W B
75
H
W B
R
IntroductionTim
ber To Masonry
Connections
Timber Fram
eE
ngineered Wood
Products (E
WP
)S
olid Timber/R
oof TrussTruss To W
allplateC
onnectionsM
ultiple C
onnectionsR
estraint Straps
Ancillary P
roductsC
ustom C
onnectorD
esign Template
JH/JHI - Masonry Joist Hangers
JH Performance - Roof Truss & Solid Timber Joists
Product Code
DimensionsFixings(3.75 x30mm)
Safe Working Loads (kN) Characteristic Capacity of Hanger (kN)
UpliftShortTerm
Masonry Crushing Strength
Uplift
Masonry Crushing Strength
W H B Truss / Joist
2.8 N/mm2 3.5 N/mm2 7.0 N/mm2 2.8 N/mm2 3.5 N/mm2 7.0 N/mm2
All widths All widths 38 to100mm wide
125 to198mm wide All widths All widths 38 to
100mm wide125 to
198mm wideJH-50-150 50 140 64 2 1.0 6.0 7.54 9.1 7.54 2 10.94 13.68 15.99 13.68
JH-50-175 50 165 64 2 1.0 6.0 7.54 9.1 7.54 2 10.94 13.68 15.99 13.68
JH-50-200 50 190 64 2 1.0 6.0 7.54 9.1 7.54 2 10.94 13.68 15.99 13.68
JH-50-225 50 215 64 2 1.0 6.0 7.54 9.1 7.54 2 10.94 13.68 15.99 13.68
JH-50-250 50 240 64 2 1.0 6.0 7.54 9.1 7.54 2 10.94 13.68 15.99 13.68
JH-50-275 50 265 64 2 1.0 6.0 7.54 9.1 7.54 2 10.94 13.68 15.99 13.68
JH-50-300 50 290 64 2 1.0 6.0 7.54 9.1 7.54 2 10.94 13.68 15.99 13.68
Hangers shown above are for 47mm joists, JHs are available in widths of 38, 44, 47, 50, 63, 75, 88, 92, 100, 125, 150 and 198mm.Standard return sizes available 100, 115, 125, 140 & 215mm.
ORDER DETAILS - JHR/JHIR - RETURN STYLE HANGERTo specify return style hangers add “R” to the standard JH product code.
Example(50 x 200 timber on 100mm blockwork)JH 50-200 with a 100mm return flange = JHR-50-200-100
ORDER DETAILS - JHST/JHIST - STRADDLE STYLE HANGERTo specify straddle style hangers add “ST” to the standard JH product code.
Example(2no. 50 x 200 timber on 100mm blockwork)JH 50-200 x (2) to suit 100mm blockwork = JHST-50-200-100
General Notes
Joist hanger must abut face of masonry wall to perform as quoted. Specifying return style hangers improves the chances of on-site compliance and produces a more robust detail.All hangers to suit timbers 150mm deep and above are manufactured with their H dimension 10mm undersize to allow for notching to provide a flush ceiling line.In order to achieve the stated safe working loads/characteristic capacities all masonry must be fully cured and a minimum of three block course (675mm) must be constructed above hanger. Where no masonry exists above see Cullen’s RA or RBJH.R dimension stands for return tab only and does not provide restraint.
1.
2.
3.
4.
ImportantParallel restraint is required for Joist Hangers, except the RA. For information on restraint refer to page 107.
ImportantIn order to achieve the stated safe working loads all masonry must be fully cured and a minimum of three block course (675mm) must be constructed above hanger before floor is loaded.
Fixing to Steel
Masonry hanger positioned on top flange of steelwork and fixed directly to top flange by shot firing (maximum steel fixing thickness 12mm) using:
- 4no. Spit Spitfire P370 Cartridge tool using SC9 nails or equivalent, into the hanger top flanges (2no. fixings per leg).
SAFE WORKING LOADS (kN) for all hangers 7.45kN - uplift 1kN.
Alternative fixing to shot firing, fix hanger top flange directly to top flange of steelwork using 4no. Tek screws.
SAFE WORKING LOADS (kN) for all hangers 6.90kN - uplift 1kN.
Fixing through top flange
Maximum gap from truss/joist to blockwork = 6mm
Rear face of hanger must tightly abut the blockworkGap = 0mm
675mmmin.