29
Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical Programme - Versailles Congress Center Page 1 / 29 S S S E E E S S S S S S I I I O O O N N N A A A . . . 0 0 0 : : : O O O P P P E E E N N N I I I N N N G G G S S S E E E S S S S S S I I I O O O N N N Monday June 25, 2007 - 9:00 - 10:30 - Room: A I.0 Opening Lecture: "XXI th Century: The Century of Nanoconvergence - From Data Storage to Energy Cables" by Jean-Claude BOUDENOT, Thalès S S S E E E S S S S S S I I I O O O N N N A A A . . . 1 1 1 : : : H H H V V V / / / E E E H H H V V V C C C A A A B B B L L L E E E S S S Y Y Y S S S T T T E E E M M M - - - D D D E E E V V V E E E L L L O O O P P P M M M E E E N N N T T T S S S Monday June 25, 2007 - 11:00 - 12:30 - Room: A Chairman: F. RÜTER - ABB Power Technologies (Sweden) Rapporteur: Y. MAUGAIN - RTE DDOP (France) A.1.1 Development of 400 kV class XLPE insulated power cable and accessories Akihisa Kuwaki, Katsuyuki Hayashi; EXSYM Corp., Kumagaya, Saitama, Japan Kenji Kato; EXSYM Corp., Mito, Aichi, Japan Noriaki Imai; EXSYM Corp., Sagamihara, Kanagawa, Japan A.1.2 400 kV XLPE insulated cable systems with dry plug-in outdoor terminations Johannes Kaumanns, Gero Schröder, Jürgen Lehnhäuser, Volker Stroot, Andreas Weinlein; Südkabel, Mannheim, Germany A.1.3 Development of one piece type joint (self pressurized joint) for 400 kV XLPE cables Yoichi Watanabe, Koji Fudamoto, Koji Kishi, Tsuyoshi Uozumi, Atsushi Terayama; J- Power Systems Corp., Osaka, Japan A.1.4 French experience in aluminium laminated screens Frédéric Lesur; EDF R&D, Moret-sur-Loing, France Pierre Argaut; SILEC CABLE, Montereau, France Laurent Benard; PRYSMIAN, Paron, France Pierre Mirebeau; NEXANS France, Calais, France A.1.5 Development of the high voltage extruded cables: Italian experience Ernesto Zaccone; PRYSMIAN Cables & Systems, Milan, Italy Antonio Fara; ENEL, Rome, Italy A.1.6 400 kV 2500mm² XLPE cable system prequalification and type test for Middle East environment J. Matallana, François Gahungu, M. Duvivier, D. Dubois, Pierre Mirebeau; NEXANS France, Calais, France

Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 1 / 29

SSSEEESSSSSSIIIOOONNN AAA...000::: OOOPPPEEENNNIIINNNGGG S SSEEESSSSSSIIIOOONNN Monday June 25, 2007 - 9:00 - 10:30 - Room: A

I.0 Opening Lecture: "XXI th Century: The Century of Nanoconvergence - From Data Storage to Energy Cables" by Jean-Claude BOUDENOT, Thalès

SSSEEESSSSSSIIIOOONNN AAA...111::: HHHVVV /// EEEHHHVVV CCCAAABBBLLLEEE SSSYYYSSSTTTEEEMMM --- DDDEEEVVVEEELLLOOOPPPMMMEEENNNTTTSSS Monday June 25, 2007 - 11:00 - 12:30 - Room: A

Chairman: F. RÜTER - ABB Power Technologies (Sweden) Rapporteur: Y. MAUGAIN - RTE DDOP (France)

A.1.1 Development of 400 kV class XLPE insulated power cable and accessories Akihisa Kuwaki, Katsuyuki Hayashi; EXSYM Corp., Kumagaya, Saitama, Japan Kenji Kato; EXSYM Corp., Mito, Aichi, Japan Noriaki Imai; EXSYM Corp., Sagamihara, Kanagawa, Japan

A.1.2 400 kV XLPE insulated cable systems with dry plug-in outdoor terminations Johannes Kaumanns, Gero Schröder, Jürgen Lehnhäuser, Volker Stroot, Andreas Weinlein; Südkabel, Mannheim, Germany

A.1.3 Development of one piece type joint (self pressurized joint) for 400 kV XLPE cables Yoichi Watanabe, Koji Fudamoto, Koji Kishi, Tsuyoshi Uozumi, Atsushi Terayama; J-Power Systems Corp., Osaka, Japan

A.1.4 French experience in aluminium laminated screens Frédéric Lesur; EDF R&D, Moret-sur-Loing, France Pierre Argaut; SILEC CABLE, Montereau, France Laurent Benard; PRYSMIAN, Paron, France Pierre Mirebeau; NEXANS France, Calais, France

A.1.5 Development of the high voltage extruded cables: Italian experience Ernesto Zaccone; PRYSMIAN Cables & Systems, Milan, Italy Antonio Fara; ENEL, Rome, Italy

A.1.6 400 kV 2500mm² XLPE cable system prequalification and type test for Middle East environment J. Matallana, François Gahungu, M. Duvivier, D. Dubois, Pierre Mirebeau; NEXANS France, Calais, France

Page 2: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 2 / 29

SSSEEESSSSSSIIIOOONNN BBB...111::: LLLVVV /// MMMVVV SSSYYYSSSTTTEEEMMMSSS (((111))) Monday June 25, 2007 - 11:00 - 12:30 - Room: B

Chairman: S. SALDIVAR - Conductores Monterrey (Mexico) Rapporteur: A. DOULET - ERD (France)

I.1 Invited paper: "Highly Reliable Extruded Dielectric Insulation Systems" by Robert KEEFE - EPRI (USA)

B.1.1 Investigation of the aging characteristics of CST termination made of silicone rubber at contamination area Tatsuya Nakamura, Yoshihide Kozasa, Akiyoshi Sato, Taikichi Kondo; Chubu Electric Power Co., Nagoya, Japan Masao Ohtsubo; Sumitomo 3M, Sagamihara-Shi, Kanagawa, Japan

B.1.2 Evaluation of different replacement strategies of a medium voltage cable joint based on statistical failure analysis Rogier A. Jongen, Peter H. F. Morshuis, Johan J. Smit; Delft University of Technology, The Netherlands Anton Janssen; Nuon Assetmanagement, Arnhem, The Netherlands Edward Gulski; Ksandr, Delft, The Netherlands

B.1.3 Initial experience in operating an 11 kV flexible cable system for emergency supply in Hong Kong K.K. Leung, K.C. Wong; CLP Power Hong Kong Limited, Hong Kong, China

B.1.4 Emergency conditions applied to triplex medium-voltage XLPE cables having flat strap neutrals S. Pélissou; IREQ, Varennes, Canada Jacques Côté, Serge St-Antoine, Julien Dallaire; Réseau de Distribution, Hydro-Québec, Montréal, Canada

B.1.5 New specification to check cable sheath resistance to termites Yves Brument, Frédéric Lesur; EDF R&D, Moret-sur-Loing, France

Page 3: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 3 / 29

SSSEEESSSSSSIIIOOONNN AAA...222::: HHHVVV /// EEEHHHVVV LLLAAARRRGGGEEE PPPRRROOOJJJEEECCCTTTSSS Monday June 25, 2007 - 14:30 - 16:00 - Room: A

Chairman: J. BECKER - BECKER Consult (Belgium) Rapporteur: P. ARGAUT - SILEC CABLE (France)

A.2.1 Large projects of EHV underground cable systems Kjell Bjorlow-Larsen; NEXANS Norway AS, Oslo, Norway Ernesto Zaccone; PRYSMIAN Cables & Systems, Milan, Italy Fabian Shell; Brugg Kabel Wolker Wacht; NKT Cables, Germany Pierre Argaut; SILEC CABLE, Montereau, France

A.2.2 The St. John´s Wood - Elstree experience: testing a 20 km long 400 kV XLPE-insulated cable system after installation Gero Schröder; Südkabel, Mannheim, Germany Ronald Plath; IPH, Berlin, Germany Simon Sutton; National Grid, Warwick, UK

A.2.3 New 345 kV underground extruded cable system project in Connecticut Pierre Argaut, Marie-Hélène Luton; SILEC CABLE, Montereau, France Peter Tirinzoni; Northeast Utilities , Hartford, USA John Lanning; New River Electrical Corp , Cloverdale , USA Rachel Mosier; Power Delivery Consultants, Ballston Lake, NY, USA

A.2.4 87/150 (170) kV Koksijde-Slijkens link Yves Leroy, D. Liemans; NEXANS Benelux, Charleroi, Belgium François Gahungu; NEXANS France, Calais, France

A.2.5 Undergrounding and reorganization of the electrical system of the city of Madrid Josu Orella Sáenz, Roberto Cabero Alonso; Iberdrola Ingeniería y Construcción, Erandio, Spain

A.2.6 HV power cables installed in multi-purpose tunnels, a challengeable option! Frank H. de Wild, Wim Boone; KEMA, Arnhem, The Netherlands

Page 4: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 4 / 29

SSSEEESSSSSSIIIOOONNN BBB...222::: LLLVVV /// MMMVVV SSSYYYSSSTTTEEEMMMSSS (((222))) Monday June 25, 2007 - 14:30 - 16:00 - Room: B

Chairman: J. ROVIRA - Grupo General Cables Sistemas (Spain) Rapporteur: S. TOGNALI - PRYSMIAN C&S (France)

B.2.1 New high performance, environmentally friendly MV power cable insulations Mark Easter; General Cable, Indianapolis, USA Elisenda Masarella; General Cable, Manlleu, Spain Luciano Azpiazu, Gonzalo Maiz; Iberdrola, Bilbao, Spain

B.2.2 New concept in cables and accessories for low voltage underground distribution in Spain Gonzalo Maíz, Luciano Azpiazu; Iberdrola, Bilbao, Spain Joaquim Riera; Niled, Manresa, Spain Jacint Rovira; General Cable, Barcelona, Spain

B.2.3 Corrosion kinetics of LV cable galvanised steel screen Yves Brument; EDF R&D, Moret-sur-Loing, France Philippe Giffard, Manuel Lodeiro, Gérard Bordeselle; Draka Paricable France, France Eric Beucher; CRITT Haute Normandie, France

B.2.4 A new customized pulling-cable software Janislaw Tarnowski, Mircea Iordanescu, Denis Valiquette, Gilles Ratel, François Bergeron, Minh Trinh; IREQ, Varennes, Canada

B.2.5 Service experiences for MV cable network – optimistic or pessimistic state of the art? Aleksandra Rakowska; Poznan University of Technology, Poznan, Poland

B.2.6 Harmonising MV cables Frédéric Lesur, Yves Brument; EDF R&D, Moret-sur-Loing, France

Page 5: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 5 / 29

SSSEEESSSSSSIIIOOONNN AAA...333::: CCCAAABBBLLLEEESSS FFFOOORRR TTTHHHEEE FFFUUUTTTUUURRREEE Monday June 25, 2007 - 16:30 - 18:15 - Room: A

Chairman: J-L PARPAL - Hydro Quebec (Canada) Rapporteur: Ch. AUCOURT - RTE (France)

A.3.1 Superconducting cables - status and applications Jean-Maxime Saugrain; NEXANS France, Clichy, France Frank Schmidt; NEXANS GmbH&Co.KG, Hannover, Germany Pierre Mirebeau; NEXANS France, Calais, France

A.3.2 Installation and commissioning of TRIAX HTS cable David T. Lindsay; Southwire Company, Carrollton, USA

A.3.3 Installing a long-distance HTS cable Alex Geschiere, Erika Piga; Nuon, Duiven, The Netherlands Dag Willén; NKT Cables, Brondby, Denmark Peter Barendregt; NKT Cables, Köln, Germany Nancy Lynch; Praxair, Danbury, USA

A.3.4 Development and demonstration of a long length transmission voltage cold dielectric superconducting cable to operate in the Long Island Power Authority grid Frank Schmidt; NEXANS GmbH&Co.KG, Hannover, Germany James Maguire; American Superconductor, Westborough, USA Shawn Bratt; AIR LIQUIDE DTA, Sassenage, France Tom Welsh; Long Island Power Authority, Hicksville, USA Nicolas Lallouet; NEXANS France, Calais, France

A.3.5 Potential of multilayer coating for improvement of the dielectric withstand in gas insulated cable Mounir Hairour, Jean-Luc Bessede; AREVA T&D, Villeurbanne, France Endre Mikes; AREVA T&D AG, Oberentfelden, Switzerland

A.3.6 Gas insulated transmission lines – under-ground bulk power transmission achieving a maximum of operational safety and reliability Dirk Kunze, Stephan Pöhler, Hermann. Koch, Joachim Alter; SIEMENS AG, Erlangen, Germany Erich Binder, Jürgen Türk; VERBUND Austrian Hydro Power, Salzburg, Austria

Page 6: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 6 / 29

SSSEEESSSSSSIIIOOONNN BBB...333::: IIINNNDDDUUUSSSTTTRRRIIIAAALLL &&& SSSPPPEEECCCIIIAAALLL CCCAAABBBLLLEEESSS Monday June 25, 2007 - 16:30 - 18:00 - Room: B

Chairman: F. KRÄHENBÜHL - NEXANS (Switzerland) Rapporteur: J-C. TOURAINE - PRYSMIAN C&S (France)

B.3.1 Irradiation technologies and compounds for cables cross-linking – developments for flat and heat-trace cables Sophie Rouif; IONISOS, Dagneux, France

B.3.2 Electron beam curing of EVM and HNBR filled cable sheath compounds Manuel La Rosa, John Dewar, Frank Taschner; LANXESS Deutschland, Leverkusen, Germany

B.3.3 Utilisation of ceramizing materials in fire resisting cables and accessories Bruno Weider; NEXANS Schweiz AG , Breitenbach, Switzerland

B.3.4 Development of ceramifying insulation materials for cables in fire situations Graeme Alexander, Ken Barber; Olex Australia, Tottenham, Australia

B.3.5 Choices of flame retardant materials for cables with improved fire behaviour Dominique Duphil, Bernard Poisson, Pierre Argaut; SILEC CABLE, Montereau, France Javier Barbeta, M. Carmen Pascual, Juan D. Martinez; General Cable, Manlleu, Spain

B.3.6 Use of nanofillers in high performance of MV cables under fire conditions. Daniel Calveras, Jordi Grabolosa; General Cable, Manlleu, Spain Isabelle Canerot; SILEC CABLE, Montereau, France

B.3.7 Polymeric armor design of an improved protection to mechanical stresses and fluids for Oil Gas and Petrochem (OGP) applications". Luca De Rai, Marco Frigerio, Paolo Veggetti; PRYSMIAN Cables & Systems, Milan, Italy

Page 7: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 7 / 29

SSSEEESSSSSSIIIOOONNN AAA...444::: DDDIIIAAAGGGNNNOOOSSSTTTIIICCCSSS (((111))) Tuesday June 26, 2007 - 9:00 - 10:30 - Room: A

Chairman: A. RAKOWSKA - Poznan Univ. Of Technology (Poland) Rapporteur: P-M. DEJEAN - PRYSMIAN - PLURIDIS (France)

A.4.1 Permanent on-line monitoring of MV power cables based on partial discharge detection and localisation - an update Fred Steennis, Peter van der Wielen, Bartjan Kaptein; KEMA-TDT, Arnhem, The Netherlands

A.4.2 On-site VHF partial discharge detection on power cable accessories Sander Meijer, Pantelis D. Agoris, Johan J. Smit; Delft University of Technology, The Netherlands Paul P. Seitz; Seitz Instruments AG, Niederrohrdorf, Switzerland Theo J.W.H. Hermans, Lawrence Lamballais; PRYSMIAN C&S, Delft, The Netherlands

A.4.3 Continuous on-line monitoring of PDS in HV cables Hao Zhang, Toan Phung, Zhao Liu, Trevor Blackburn; University of New South Wales, Sydney, Australia

A.4.4 Partial discharge detection in power cables: practical limits as a function of cable length Andrea Cavallini, Gian Carlo Montanari; University of Bologna, Italy S. Chandrasekar; Sona College of Technology, Tamilnadu, India

A.4.5 A study on the defect identification of power cable by pulse analysis map (PA map) using high frequency partial discharge (HFPD) detection Ji-Hong Kim, Ja-Yoon Koo ; Hanyang University, Ansan, Kyungido, South Korea Jin-Gi Kim; Agency for Defense Dev., Daejon, South Korea Jeong-Tae KIM, Daejin University, Pochun Kyungido, Korea

A.4.6 New approach for high voltage cable on-site testing Kay Rethmeier, Peter Mohaupt; BAUR Pruef- und Messtechnik, Sulz, Austria Volker Bergmann, Stefan Seifert, Wilfried Kalkner; Technische Universitaet Berlin, Germany

Page 8: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 8 / 29

SSSEEESSSSSSIIIOOONNN BBB...444::: HHHVVV /// EEEHHHVVV CCCAAABBBLLLEEESSS --- U UUPPPGGGRRRAAADDDIIINNNGGG Tuesday June 26, 2007 - 9:00 - 10:30 - Room: B

Chairman: S. SAKUMA - VISCAS (Japan) Rapporteur: P. MIREBEAU - NEXANS FRANCE (France)

B.4.1 Health index, a tool for asset management Eric Dorison, Frédéric Lesur, Dominique Meurice; EDF R&D, Moret-sur-Loing, France

B.4.2 Evaluation of the condition and the performance of underground high voltage fluid filled links at Hydro-Québec Christian Royer, Ray Awad; Hydro-Québec, Montreal, Canada

B.4.3 Upgrading and uprating of underground existing systems Frédéric Lesur; EDF R&D, Moret-sur-Loing, France

B.4.4 Renewal works of underground transmission system in KEPCO Takeshi Kaya, Eiji Fujiwara, Masao Matsumura; Power System Engineering Center, Osaka, Japan

B.4.5 Re-evaluation of 150 kV cable capacity D. van Houwelingen; ENECO-Netbeheer, Rotterdam, The Netherlands

B.4.6 Modern cable systems in steel pipes - new designed XLPE-insulated cables substituting paper-insulated pipe-type cables Volker Aue, Wilfried Rosebrock; NEXANS GmbH&Co.KG, Hannover, Germany

B.4.7 Increased voltage for the HVDC light product range – a complete solution Marc Jeroense, Mikael Bergkvist, Anders Gustafsson; ABB Power Systems, Karlskrona, Sweden Hans Rapp, Torbjöm Sörqvist, Jörgen Svahn; ABB Power Products, Alingsås, Sweden

Page 9: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 9 / 29

SSSEEESSSSSSIIIOOONNN AAA...555::: DDDIIIAAAGGGNNNOOOSSSTTTIIICCCSSS (((222))) Tuesday June 26, 2007 - 11:00 - 12:30 - Room: A

Chairman: W. BOONE - KEMA Nederland BV (The Netherlands) Rapporteur: C. LAURENT - CNRS - LGT (France)

A.5.1 US experience on condition assessment of various types of taped cable systems by dissolved gas analysis based on a novel sampling and analysis Nirmal Singh, Sandeep K. Singh, Rommy R. Reyes, Oscar E. Morel; Detroit Edison Company, Detroit, USA Walter Zenger; Pacific Gas & Electric, California, USA

A.5.2 Remarkable tan delta suppression of oil filled cable insulation with extremely degraded tan delta oil Tohru Takahashi, Takenori Nakajima; VISCAS Corporation, Ichihara, Japan Masahiko Nakade, Kenichi Ide; Tokyo Electric Power Company, Yokohama, Japan

A.5.3 A method for maintenance of oil filled high voltage XLPE cable terminations Knut Brede Liland, Sverre Hvidsten; SINTEF Energy Research, Trondheim, Norway Kjell Bjørneklett; BKK, Bergen, Norway

A.5.4 Diagnostic for paper cable condition assesment Thierry Espilit, Fabrice Zorzi, Vanessa Regaudie, Christophe Gaudin; EDF R&D, Moret-sur-Loing, France Roger Tambrun; EDF DRE, Paris, France

A.5.5 Application of optical fiber current sensors to underground cables Shinsuke Nasukawa, Reishi Kondo, Tatsushi Yamaguchi; Tokyo Electric Power CO., Tokyo, Japan Kazuo Amano; FUJIKURA Ltd, Tokyo, Japan Toshiharu Yamada; Takaoka Electric Mfg. Co. , Tokyo, Japan

A.5.6 Thermal transient analysis of underground cables Jan Desmet, D. Putman, G. Vanalme; Hogeschool West-Vlaanderen, Kortrijk, Belgium Ronnie Belmans; K.U.Leuven, Belgium Eric Cloet; ELIA, Brussel, Belgium

Page 10: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 10 / 29

SSSEEESSSSSSIIIOOONNN CCC...555...111::: C CCAAABBBLLLEEE SSSYYYSSSTTTEEEMMMSSS Tuesday June 26, 2007 - 11:00 - 12:30 - Room: C- Poster Session

Chairman: A. VALDENEGRO - Univ. de Chile (Chile) Rapporteur: P. GIFFARD - DRAKA PARICABLE (France)

SSEESSSSIIOONN CC..55..11 -- MMAATTEERRIIAALLSS

C.5.1.1 High Performance MV Cable Semi Conducting Shields Mark Easter; General Cable, Indianapolis, USA Isabelle Canerot; SILEC CABLE, Montereau, France

C.5.1.2 Compounding of semiconductives for high voltage cables Colin G Richardson; Buss AG, Pratteln, Switzerland

C.5.1.3 Stabilizer concepts for Silane crosslinked polyethylene cable applications Heinz Herbst; CIBA Specialty Chemicals, Basel, Switzerland Chris Fagouri; CIBA Specialty Chemicals, Tarrytown, USA

C.5.1.4 Performance of modern cables in Central Europe Detlef Wald; BOREALIS Polymers NV, Mechelen, Belgium Annika Smedberg; BOREALIS AB, Stenungsund, Sweden

C.5.1.5 Long-life XLPE insulated power cables H. Orton; OCEI, Vancouver, BC, Canada Richard Hartlein, Nigel Hampton; Georgia Inst., ECE-NEETRAC, Atlanta, USA Ram Ramachandran; The Dow Chemical Company , Somerset, USA

C.5.1.6 Development on recycling technology of XLPE Youitsu Sekiguchi, Noriyuki Ohkawa, Hitoshi Nojo, Satoru Hashimoto; J-Power Systems Corp., Tokyo, Japan

SSEESSSSIIOONN CC..55..11 –– LLVV AANNDD MMVV CCAABBLLEE SSYYSSTTEEMMSS

C.5.1.7 Innovative bolted connector for LV and MV with stepless shear bolts H. Laurent; PFISTERER, Illzach France H. Gross; PFISTERER AG, Winterbach, Germany

C.5.1.8 Surge propagation and protection of underground distribution cables Jae-bong Lee, Ju-yong Kim, Byung-sook Kim, Chul-bae Park, Yeon-ha Jung; KEPCO, Daejeon, South Korea

Page 11: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 11 / 29

C.5.1.9 Advances in chemical rejuvenation: extending MV cable life 40 years Glen J. Bertini, Gary A. Vincent; Novinium Inc., Kent, USA

C.5.1.10 Dielectric system for submarine electro hydraulic umbilical up to 35 kV Mario Daniel Teixeira Junior; MDR Consultoria, Rio de Janeiro, Brazil Luciana Abib; Marine Production Systems do Brasil, Rio de Janeiro, Brazil

C.5.1.11 A development of underground distribution cable for water-blocking and reducing protrusions Jae-bong Lee, Ju-yong Kim, Byung-sook Kim, Il-keun Song; KEPCO, Daejeon, South Korea

C.5.1.12 Development of Pre-Molded Joint for 230 kV XLPE Power Cable Hwa Jong Kim, Hyun Joo Kim, S.Y. Kim, Jae Hyuk Song; Taihan Electric Wire, Seoul, South Korea

C.5.1.13 Transition joints Ludovic Courset; RTE CNER, Paris France Pierre Hondaa; EDF R&D, Moret-sur-Loing, France

C.5.1.14 Compact various transition joints for up to 154 kV power cable Shigekazu Yokoyama, Yasuo Torai; VISCAS Corporation, Tokyo, Japan Satoshi Kaneko; VISCAS Corporation, Hirastuka, Japan Hiroshi Niinobe; VISCAS Corporation, Ichihara, Japan

C.5.1.15 Upgrading quality of 275 kV Y - branch pre-fabricated transition joint Tatsuo Nakanishi; J-Power Systems Corp., Osaka, Japan

C.5.1.16 Development of outdoor-sealing-end of prefabricated-composite-insulator for 66/77 kV XLPE cable Kimihiro Iwasaki, Atsushi Tanaka, Atsushi Toya; Tokyo Electric Power CO., Tokyo, Japan Hiromasa Satou; EXSYM Corp., Sagamihara, Kanagawa, Japan Kazuhisa Adachi, Nobuyuki Sema; SWCC SHOWA Cable System, Kanagawa, Japan

C.5.1.17 Development of dry type out-door terminations for 66 to 110 kV XLPE cable Kouichi Oono; VISCAS Corporation, Ichihara, Japan Satoshi Kaneko, Isao Takaoka; VISCAS Corporation, Hiratsuka, Japan

Page 12: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 12 / 29

SSSEEESSSSSSIIIOOONNN CCC...555...222::: C CCAAABBBLLLEEE IIINNNSSSTTTAAALLLLLLAAATTTIIIOOONNN &&& RRRAAATTTIIINNNGGG Tuesday June 26, 2007 - 11:00 - 12:30 - Room: C- Poster Session

Chairman: H. ORTON - ORTON Consulting ING (Canada) Rapporteur: A. CHAUVANCY - RTE CNER (France)

SSEESSSSIIOONN CC..55..22 –– CCAABBLLEE RRAATTIINNGG

C.5.2.1 Modern FEM-calculation tools – an ampacity calculation method for XLPE cables installed in ductbanks Johan Karlstrand, Gunnar Henning; ABB Power Systems, Karlskrona, Sweden

C.5.2.2 Application results of real-time ampacity estimation system and intelligent power cable system. S.H. Nam, J.M. Lee, C.S. Kim, K.Y. Kim, S.K. Lee; LS Cable, Anyang-si, South Korea H.L. Kim, Y.S. Kim, H.E. Lim; KEPCO, Seoul, South Korea

C.5.2.3 An adaptive monitor program for dynamic thermal rating of power cables Heinrich Brakelmann, Holger Hirsch, Armin Röhrich, Hans-Peter Scheiffarth, Joerg Stammen; University of Duisburg-Essen, Germany

C.5.2.4 HV cables operating in a dynamic rating regime, a beneficial option! Frank H. de Wild, Wim Boone; KEMA, Arnhem, The Netherlands

SSEESSSSIIOONN CC..55..22 –– CCAABBLLEE IINNSSTTAALLLLAATTIIOONN

C.5.2.5 Development on the mortar material for cable systems in a directional drilling Y. Nishiyama, S. Kobayashi, T. Ishizone, Y. Ashizawa; Chubu Electric Power Co., Nagoya, Japan

C.5.2.6 Sharing pipelines, tunnels, conduits, multipurpose structures, and rights of way among power cables, optical cables, gaslines, sewers, heating ducts, hot water pipes, and potable waterlines Jey K. Jeyapalan; DR. Jeyapalan & Associates, New Milford, CT, USA

C.5.2.7 Fire prevention method for 275 kV oil-filled cable joint in TEPCO Shinsuke Nasukawa, Atsushi Toya; Tokyo Electric Power CO., Tokyo, Japan

Page 13: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

C.5.2.8 Development and its efficacy of sheath current reduction device on underground power cable systems JI-Won Kang, Hyung-Hee Yoon, Bang-Myung Kwak; KEPCO, Daejeon, South Korea

C.5.2.9 Multiconductor cell analysis of power cable steady state Roberto Benato; University of Padova, Italy

Jicable'07 – Technical Programme - Versailles Congress Center Page 13 / 29

Page 14: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 14 / 29

SSSEEESSSSSSIIIOOONNN AAA...666::: HHHVVV /// EEEHHHVVV CCCAAABBBLLLEEESSS --- O OOPPPEEERRRAAATTTIIINNNGGG CCCOOONNNSSSIIIDDDEEERRRAAATTTIIIOOONNNSSS Tuesday June 26, 2007 - 14:30 - 16:00 - Room: A

Chairman: A. GUSTAFSSON - ABB Power Systems (Sweden) Rapporteur: G. ROINEL - RTE CNER (France)

I.2 Invited Paper: "Cigré Study Committee B1 (insulated Cables)", by Fredrik RÜTER, Chairman of SC B1 (Sweden) Fredrik Rüter; Chairman of B1 Committee, CIGRE, Sweden

A.6.1 FACTS for optimum utilisation of cable networks in power transmission Rolf Grünbaum; ABB Power Technologies AB, Vasteras, Sweden Johan Karlstrand; ABB Power Systems, Karlskrona, Sweden

A.6.2 Outsourcing preventive maintenance on underground power transmission cables Salem M. Alshibani, Ahmad Sharaf; Ministry of Energy, Yarmouk, Kuwait

A.6.3 Failure prediction in 50 kV mass-insulated power cable systems Rogier Jongen, Peter H. F. Morshuis, Johan J. Smit; Delft University of Technology, The Netherlands Anton Janssen; Nuon Assetmanagement, Arnhem, The Netherlands Edward Gulski; Ksandr, Delft, The Netherlands

A.6.4 Fire hazard of MV / HV cables installed in tunnels Christian Philippczyk; NKT Cables, Köln, Germany Keld Veno-Poulsen; NKT Cables A/S, Asneas, Denmark Terry Journeaux, Doug Gracias; PRYSMIAN Cables & Systems, Eastleigh, UK Wendy Loyens; BOREALIS AB, Stenungsund, Sweden James Robinson; BOREALIS Polymers NV, Mechelen, Belgium

A.6.5 A dynamic rating system for a hybrid 150 kV transmission system Frank H. de Wild; KEMA, Arnhem, The Netherlands Jacco Smit; Nuon Tecno, Alkmaar, The Netherlands René Trekop; Continuon netbeheer, Arnhem, The Netherlands

Page 15: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 15 / 29

SSSEEESSSSSSIIIOOONNN BBB...666::: AAAGGGEEEIIINNNGGG &&& DDDIIIAAAGGGNNNOOOSSSTTTIIICCCSSS Tuesday June 26, 2007 - 14:30 - 16:00 - Room: B

Chairman: A. QUIJANO LOPEZ - Inst. de Technologia Electrica (Spain) Rapporteur: E. DORISON - EDF R&D (France)

B.6.1 Effect of ageing on MV underground asset reliability Dominique Dercle; EDF ERD, Paris, France Cedric Spelleman; EDF R&D, Clamart, France

B.6.2 Nuclear cables: lifetime simulation Carole Monchy-Leroy; EDF R&D, Moret-sur-Loing, France Patrice Thérond; EDF SEPTEN, Villeurbanne, France

B.6.3 Time Domain Spectroscopy (TDS) as a diagnostic tool for MV XLPE underground lines Jean-François Drapeau, Daniel Jean, Jean-Luc Parpal, Carl Potvin, Daniel Lalancette, Simon Bernier, Richard L'Écuyer; IREQ, Varennes, Canada

B.6.4 Diagnosis on MV XLPE power cable by using frequency variance loss current analysis Mustapha Afifi Abdul Rahman; Dept.of Eng., Distribution Division, TNB , Selangor, Malaysia P.S. Ghosh; RUP Consultant Plus Inc., Calgary, Canada

B.6.5 Development of an innovative residual-charge measurement technique for water-tree deteriorated XLPE cable Hiroyuki Kon, Hideo Tanaka; VISCAS Corporation, Ichihara, Japan Toyoshi Tsukamoto, Hideaki Sato, Koichi Onuki; Tokyo Electric Power CO., Tokyo, Japan

B.6.6 Validating “diagnostic tests” for cables in service Joshua Perkel, Nigel Hampton, Miroslav Begovic, Richard Hartlein; Georgia Inst., ECE-NEETRAC, Atlanta, USA Joshua Perkel, Nigel Hampton, Miroslav Begovic, Richard Hartlein; Georgia Inst., ECE-NEETRAC, Atlanta, USA

Page 16: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 16 / 29

SSSEEESSSSSSIIIOOONNN AAA...777::: TTTEEESSSTTTIIINNNGGG MMMEEETTTHHHOOODDDSSS (((111))) Tuesday June 26, 2007 - 16:30 - 18:00 - Room: A

Chairman: F. STEENNIS - KEMA (The The Netherlands) Rapporteur: J-C. VANNIER - SUPELEC (France)

A.7.1 Sensitivity assessment for partial discharge measurements on solid dielectric transmission cables Mark Fenger, Howard Sedding; Kinectrics Inc., Toronto, Canada

A.7.2 On-line location of partial discharges in an electrical accessory of an underground power distribution network Bruno Cantin, François Léonard; IREQ, Varennes, Canada Daniel Fournier; Hydro-Québec, Montreal, Canada

A.7.3 PD-monitoring and on-site-commissioning-test of 400 kV XLPE-insulated cable circuits at Jebel Ali / Dubai Werner Weissenberg, Mehmet Kaba, Oldrich Sekula; Brugg Kabel AG, Switzerland T. Strehl, H. Elze, S. Markalous; LEMKE DIAGNOSTICS, Germany

A.7.4 Experience with PD measurements and commissioning tests Edwin Pultrum, Hans-Erik Keizer, S.A.M. Verhoeven; KEMA, Arnhem, The Netherlands

A.7.5 Practical issues regarding the use of dielectric measurements to diagnose the service health of MV cables Jean C. Hernandez, Nigel Hampton, Ronald Harley, Richard Hartlein; Georgia Inst., ECE-NEETRAC, Atlanta, USA

A.7.6 Evolution of space charge and internal electric field distributions in HVDC cable under long term testing J. Matallana, H. Janah, Pierre Mirebeau; NEXANS France, Calais, France Bjørn Sanden; NEXANS Norway AS, Oslo, Norway Jérôme Castellon, Serge Agnel, P. Notingher jr, Alain Toureille; LEM, Univ. de Montpellier, France

Page 17: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 17 / 29

SSSEEESSSSSSIIIOOONNN BBB...777::: HHHVVV /// EEEHHHVVV DDDCCC CCCAAABBBLLLEEESSS Tuesday June 26, 2007 - 16:30 - 18:00 - Room: B

Chairman: M. SHULALOV - JSC "VNIIKP" (Russia) Rapporteur: A. TOUREILLE - LEM Montpellier Univ. (France)

B.7.1 Development of extruded single core cables for deep waters Mikael Bergkvist, Ola Hansson, Marc Jeroense, Claes Sonesson; ABB Power Systems, Karlskrona, Sweden

B.7.2 The Norned HVDC link – cable design and performance Thomas Worzyk, Mats Sjöberg; ABB Power Systems, Karlskrona, Sweden Jan-Erik Skog; Statnett, Oslo, Norway Kees Koreman; Tenne T, Arnhem, The Netherlands

B.7.3 Development of DC +/- 250 kV coaxially-integrated return conductor extruded cable Seishi Hirano, Junichi Haraguchi; Electric Power Development, Tokyo, Japan Takehiko Mizuno; VISCAS Corporation, Ichihara, Japan Yoshihisa Nagoya; VISCAS Corporation, Tokyo, Japan

B.7.4 Effect of semicon-insulation interface on space charge formation in HVDC polymeric cables Davide Fabiani, Gian Carlo Montanari; University of Bologna, Italy Riccardo Bodega; PRYSMIAN C&S, Delft, The Netherlands L.A. Dissado; University of Leicester, UK Christian Laurent, Gilbert Teyssedre; Université Paul Sabatier, Toulouse, France Alfred Campus, Ulf H. Nilsson; BOREALIS AB, Stenungsund, Sweden Peter H. F. Morshuis; Delft University of Technology, The Netherlands

B.7.5 Measurement and modeling of space charge accumulation in polymeric HVDC cable systems Riccardo Bodega; PRYSMIAN C&S, Delft, The Netherlands Peter H. F. Morshuis; Delft University of Technology, The Netherlands G. Perego; PRYSMIAN Cables & Systems, Milan, Italy

B.7.6 The use of model cables for evaluation of DC electrical properties of polymeric cable materials Ulf H. Nilsson, Alfred Campus; BOREALIS AB, Stenungsund, Sweden Gian Carlo Montanari; University of Bologna, Italy Peter H. F. Morshuis; Delft University of Technology, The Netherlands

Page 18: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 18 / 29

SSSEEESSSSSSIIIOOONNN CCC...777...111::: A AAGGGEEEIIINNNGGG Tuesday June 26, 2007 - 16:30 - 18:00 - Room: C - Poster Session

Chairman: G.C. MONTANARI - Bologna Univ. (Italia) Rapporteur: B. POISSON - SILEC CABLE (France)

SSEESSSSIIOONN CC..77..11 –– IINNSSUULLAATTIIOONN AANNDD SSPPAACCEESS CCHHAARRGGEESS

C.7.1.1 A user-friendly tool for simulating the time-dependent field distribution in PE insulation on the basis of a physical approach Séverine Le Roy, Fakher Boufayed, Fulbert Baudoin, Gilbert Teyssedre, Christian Laurent; Université Paul Sabatier, Toulouse, France

C.7.1.2 Computer simulation of measurements on XLPE cables Jim Lyall, Frith Foottit; Queensland University of Technology, Australia

C.7.1.3 Effect of cross-linking and antioxidant on the conductivity of the polyethylene M. Houabes; University Badji Mokhtar of Annaba, Algeria

C.7.1.4 Annealing effect on the conductivity of XLPE insulation in power cable Juan Belana, Jordi Òrrit, José Antonio Diego, Miguel Mudarra; Universidad de Catalunya, Barcelona, Spain Fabián Frutos, Miguel Acedo; Universidad de Sevilla, Spain

C.7.1.5 Effect of the dielectric strength test on dielectric properties Z. Á. Tamus, E. Németh; Budapest University of Technology, Hungary

C.7.1.6 Space charge measurements in XLPE insulated mid-voltage cable: correlation with cable performance. Idalberto Tamayo, Jordi Òrrit, José Antonio Diego; Universidad de Catalunya, Barcelona, Spain

SSEESSSSIIOONN CC..77..11 –– WWAATTEERR TTRREEEEIINNGG

C.7.1.7 Water treeing test results for different XLPE compounds obtained with needle techniques Mikhail Shuvalov, Vladimir Ovsienko, Yuri Obraztsov; VNIIKP, Moscow, Russia Andrzej Urbanczyk; BOREALIS, Poznan, Poland Jan-Ove Boström; BOREALIS AB, Stenungsund, Sweden

Page 19: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 19 / 29

C.7.1.8 Crosslinking and water treeing in polyethylene insulation Florin Ciuprina; Politehnica University of Bucharest, Romania Jean César Filippini, Gisèle Teissèdre; LEMD - CNRS / UJF, Grenoble, France Alfred Campus, Annika Smedberg; BOREALIS AB, Stenungsund, Sweden

C.7.1.9 Initiation site analysis of vented water trees growing from the conductor screen of service and laboratory aged XLPE cable insulation Karl-Michael Jäger, Annika Smedberg, Ulf H. Nilsson; BOREALIS AB, Stenungsund, Sweden Sverre Hvidsten, Hallvard Faremo, Mildrid Selsjord; SINTEF Energy Research, Trondheim, Norway Stine Kvande; NTNU, Dept. of Physics, Trondheim, Norway

C.7.1.10 Exploring the water treeing inhibition effect of antioxidants for XLPE insulation Gabriel Matey, D. Labbé; Products and Marketing Ltd, Geneva, Switzerland

C.7.1.11 Influence of the temperature and the electric field on the space charge injection phenomena in trees-containing cable insulation Jérôme Castellon, P. Notingher jr; LEM, Univ. de Montpellier, France Dimitri Beauguitte, G. Platbrood, Yvan Tits; LABORELEC, Linkebeek, Belgium Damien Barras, H. Janah; NEXANS France, Calais, France

C.7.1.12 Study of thermally and water tree aged polyethylene by infrared spectroscopy, absorption currents and space charge measurements Christina Stancu, Petru V. Notingher; University Politehnica of Bucharest, Romania P. Notingher jr, Jérôme Castellon, Serge Agnel, Alain Toureille; LEM, Univ. de Montpellier, France Aleksandra Rakowska, Krzysztof. Siodla; Poznan University of Technology, Poznan, Poland

C.7.1.13 Water treeing at high hydrostatic pressure and temperatures Hallvard Faremo, Sverre Hvidsten, Jan Tore Benjaminsen; SINTEF Energy Research, Trondheim, Norway Atle Harald Børnes; Statoil ASA, Bergen, Norway

Page 20: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 20 / 29

SSEESSSSIIOONN CC..77..11 –– AAGGEEIINNGG

C.7.1.14 Improved understanding of MV cable performance through extensions of existing ageing protocols Nigel Hampton, Richard Hartlein; Georgia Inst., ECE-NEETRAC, Atlanta, USA

C.7.1.15 A molecular approach to the electrical aging of polymeric cables Jean-Pierre Crine; Technology Consultant, St Bruno, Canada

C.7.1.16 Kinetic modelling of phenol stabiliser efficiency in polyethylene submited to nuclear environments Xavier Colin, Ludmila Audouin, Jacques Verdu; ENSAM, Paris, France Carole Monchy-Leroy; EDF R&D, Moret-sur-Loing, France

C.7.1.17 A numerical method for 3D-description of scattered characteristic aging data from multistress aged XLPE-cable insulation Mark Reuter, Ernst Gockenbach, Hossein Borsi; Schering Inst., Leibnitz Universität, Hannover, Germany

C.7.1.18 Understanding and optimization of long term ageing in cable industry Thomas Stuhldreier, Jérôme Fournier; NEXANS Research Center, Lyon , France

C.7.1.19 Electrical and physico-chemical analysis of Belgium medium voltage cables data bank Jérôme Castellon, Serge Agnel, P. Notingher jr, Alain Toureille; LEM, Univ. de Montpellier, France Dimitri Beauguitte, G. Platbrood, Yvan Tits; LABORELEC, Linkebeek, Belgium

C.7.1.20 Research on the breakdown mechanism of a 22 kV power cable joint Xiaolin Chen, Naikui Gao, Kai Wu, Yonghong Cheng; Xi'an Jiaotong University, Xi'an, Shaanxi, China

Page 21: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 21 / 29

SSSEEESSSSSSIIIOOONNN CCC...777...222::: D DDIIIAAAGGGNNNOOOSSSTTTIIICCCSSS &&& MMMAAAIIINNNTTTEEENNNAAANNNCCCEEE Tuesday June 26, 2007 - 16:30 - 18:00 - Room: C - Poster Session

Chairman: G. BOULBOL - LIBAN CABLES SAL (Lebanon) Rapporteur: B. DHUICQ - SILEC CABLE (France)

SSEESSSSIIOONN CC..77..22 –– DDIIAAGGNNOOSSTTIICCSS

C.7.2.1 Insulation diagnosis of high voltage power cables Edward Gulski, Piotr Cichecki, Johan J. Smit; Delft University of Technology, The Netherlands Frank de Vries; Nuon Tecno, Alkmaar, The Netherlands Paul P. Seitz, Ben Quak; Seitz Instruments AG, Niederrohrdorf, Switzerland Frank Petzold; SebaKMT, Baunach, Germany

C.7.2.2 Wavelet analysis based scheme for fault detection and classification in underground power cable systems Ho-Woong Choi, Byoung-Woon Min, Hee-Chul Myoung, Byoung-Ho Lee; Hyundai Heavy Industries, Kyounggi, South Korea Sang-Moon Cho; NeoTelecom, Seoul, South Korea

C.7.2.3 Feasibility study on application of WiMAX technology to underground cables data acquisition Hee-Chul Myoung, Ho-Woong Choi, Byoung-Woon Min, Dong-Ho Park; Hyundai Heavy Industries, Kyounggi, South Korea Yong-Joo Kim; NeoTelecom, Seoul, South Korea

C.7.2.4 Advanced solution for on-site diagnosis of distribution power cables Edward Gulski, Johan J. Smit; Delft University of Technology, The Netherlands Frank Petzold; SebaKMT, Baunach, Germany Paul P. Seitz, Ben Quak; Seitz Instruments AG, Niederrohrdorf, Switzerland Frank de Vries; Nuon Tecno, Alkmaar, The Netherlands

Page 22: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 22 / 29

SSEESSSSIIOONN CC..77..22 –– PPAARRTTIIAALL DDIISSCCHHAARRGGEESS MMEEAASSUURREEMMEENNTTSS

C.7.2.5 Experiences with PD offline diagnosis on MV cables – knowledge rules for asset decisions Frank Petzold, Michael Beigert; SebaKMT, Baunach, Germany Edward Gulski; Delft University of Technology, The Netherlands

C.7.2.6 Sensitivity verification procedure of VHF PD detection systems Sander Meijer, Pantelis D. Agoris, Johan J. Smit; Delft University of Technology, The Netherlands Theo J.W.H. Hermans, Lawrence Lamballais; PRYSMIAN C&S, Delft, The Netherlands

C.7.2.7 50 Hz Partial Discharge Diagnostics - experience of N-Ergie AG. Minimizing cable failures by reliability-centered maintenance of networks Frank Verschraegen; IMCORP Europe BVBA, Lochristi, Belgium

C.7.2.8 Partial discharge diagnostic for cable terminations Ruben Grund, Thomas Klein; PFISTERER AG, Winterbach, Germany Denis Denissov; University of Stuttgart, Ostfildern, Germany

C.7.2.9 On-site partial discharge testing of distribution class cables using VLF and power frequency excitation Detlev W. Gross, Markus Soeller; Power Diagnostix Systems GmbH, Aachen, Germany

C.7.2.10 Novel method for on-site testing and diagnosis of transmission cables up to 250 kV Paul P. Seitz, Ben Quak; Seitz Instruments AG, Niederrohrdorf, Switzerland Edward Gulski, Piotr Cichecki; Delft University of Technology, The Netherlands Frank de Vries; Nuon Tecno, Alkmaar, The Netherlands Frank Petzold; SebaKMT, Baunach, Germany

C.7.2.11 Partial discharge diagnosis on live EHV power cable using planar UWB antenna Noh-Joon Park, Dong-Hoon Shin, Kyaw-Soe Lwin, Youn-Chan Yim, Dae-Hee Park; Wonkwang University, Iksan, South Korea Doo-Hyun Hwang, Jong-Cheon Lim; Taihan Electric Wire, Seoul, South Korea

Page 23: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 23 / 29

SSEESSSSIIOONN CC..77..22 –– CCAABBLLEE MMAAIINNTTEENNAANNCCEE

C.7.2.12 Leak location in oil paper cables Dominique Meurice; EDF R&D, Moret-sur-Loing, France Lucien Lanzarone; RTE, Vitry-sur-Seine, France Laurent Landucci; RTE, Courbevoie, France

C.7.2.13 Hydrogen elimination from a 225 kV HPOF pipe-type line Pierre Linois; RTE - TENP - GIMR, Nanterre, France Gilles Bonnardot; RTE - TENP - GETSO, Guyancourt, France

C.7.2.14 Cable rejuvenation technology; past, present and future William Stagi, Wayne Chatterton; UtilX Corporation, Kent, USA

C.7.2.15 Monitoring based maintenance for underground cables utilizing sensor networks Byoung-Woon Min, Ho-Woong Choi, Hee-Chul Myoung, Jung-Han Kim; Hyundai Heavy Industries, Kyounggi, South Korea Sang-Bum Nam; NeoTelecom, Seoul, South Korea

C.7.2.16 Condition assessment of power cable systems in the energized state Nagu Srinivas; DTE Energy Technologies Inc, Novi, Michigan, USA Bruce Bernstein; Bruce S. Bernstein Consulting LLC USA

C.7.2.17 Diagnostic testing of MV accessories by Time Domain Spectroscopy (TDS) Carl Potvin, Daniel Jean, Daniel Lalancette, Jean-Luc Parpal, Jean-François Drapeau, Simon Bernier, Richard L'Écuyer; IREQ, Varennes, Canada

Page 24: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 24 / 29

SSSEEESSSSSSIIIOOONNN AAA...888::: CCCAAABBBLLLEEESSS &&& EEENNNVVVIIIRRROOONNNMMMEEENNNTTT Wednesday June 27, 2007 - 9:00 - 10:30 - Room: A

Chairman: A. GILLE - BEL Engineering (Belgium) Rapporteur: L. BENARD - PRYSMIAN C&S (France)

A.8.1 Making remaining life predictions for power cables using reliability analyses Jey K. Jeyapalan; DR. Jeyapalan & Associates, New Milford, CT, USA

A.8.2 Oil replacement by water in unused oil-filled power cables Boris Dardel, John-Peter Mattmann, Laurent Jaquenod, Laurent Van Rysselberghe, Sébastien Gehret, Francis Krähenbühl; NEXANS Switzerland, Cortaillod, Switzerland

A.8.3 Environmental impacts in rural area of a HV underground link Laurent Gourit, Etienne Serres, Peggy Chevalier; RTE, National Centre for Grid Expertise, Paris, France

A.8.4 Passive loops technique for electromagnetic fields mitigation: applications and theoretical considerations. Paolo Maioli, Ernesto Zaccone; PRYSMIAN Cables & Systems, Milan, Italy

A.8.5 Use of ecoconception software to design a HV cable connection Pierre Mirebeau; NEXANS France, Calais, France Laurent Benard, François Lebourdon; PRYSMIAN, Paron, France Pierre Argaut, Francis Poilleaux, Bernard Poisson; SILEC CABLE, Montereau, France

A.8.6 Ecoconception, recycling and life cycle analysis in cable industry Sophie Barbeau, Jacques Goudeau; NEXANS Research Center, Lyon, France I. Dupont; RIPS, Calais, France

Page 25: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 25 / 29

SSSEEESSSSSSIIIOOONNN BBB...888::: DDDEEESSSIIIGGGNNN (((111))) Wednesday June 27, 2007 - 9:00 - 10:30 - Room: B

Chairman: W. ZENGER - PG&E (USA) Rapporteur: F. LESUR - EDF R&D (France)

B.8.1 The use of insulated wires Milliken conductors in high power transmission underground AC lines D. Dubois, Pierre Mirebeau; NEXANS France, Calais, France

B.8.2 Thermal and electromagnetic modelling of power umbilicals Harald Kulbotten, Jens Kristian Lervik; SINTEF Energy Research, Trondheim, Norway T. Normann; Aker Kvaerner Subsea, Lysaker, Norway

B.8.3 Artificial materials as backfill for UG HV lines Aloisio José de Oliveira Lima, Woong Lee, Fabio Gabriel de Oliveira; PRYSMIAN, Santo André, SP, Brazil

B.8.4 Current rating of cables installed in plastic ducts Christophe Moreau; EDF R&D, Moret sur Loing, France Ludovic Courset; RTE CNER, Paris France

B.8.5 Verification of mechanical support for cables used on bridge structures at dilation point Vincent Rouillard; Victoria University, Melbourne, Australia Roman Piechota; Olex Australia, Tottenham, Australia

B.8.6 Measurements of thrust load in cable systems rigidly installed in duct / manhole structures H. T. F. Geene, Riccardo Bodega, J. C. M. van Rossum; PRYSMIAN C&S, Delft, The Netherlands

Page 26: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 26 / 29

SSSEEESSSSSSIIIOOONNN AAA...999::: SSSUUUBBBMMMAAARRRIIINNNEEE CCCAAABBBLLLEEESSS Wednesday June 27, 2007 - 11:00 - 12:30 - Room: A

Chairman: G. BALOG - NEXANS (Norway) Rapporteur: D. DUBOIS - NEXANS (France)

A.9.1 Challenges of the second submarine interconnection between Spain and Morocco Ramon Granadino, Juan Prieto, Gregorio Denche; Red Electrica de España, Madrid, Spain Fatima Mansouri; Office National de L'Electricité, Casablanca, Morocco Knut Stenseth; NEXANS Norway AS, Oslo, Norway Roberto Comellini; PRYSMIAN Cables & Systems, Milan, Italy

A.9.2 Electrical and thermal design of umbilical cable Derek Shackleton; Oceaneering Multiflex, Rosyth, UK Luciana Abib; Marine Production Systems do Brasil, Rio de Janeiro, Brazil

A.9.3 Qualification, supply and installation of the world's first 420 kV XLPE submarine cable system in Norway Gunnar Evenset, Bjørn Knutsen; NEXANS Norway AS, Oslo, Norway Jan Erik Larsen, Kirsten Faugstad; Stattnett SF, Oslo, Norway

A.9.4 Advances in chemical rejuvenation of submarine cables Glen J. Bertini; Novinium Inc., Kent, USA

A.9.5 Subsea connections to high capacity offshore windfarms: issues for consideration Roman Svoma, Leigh Williams; PowerSure Technology, Bexleyheath, London, UK

A.9.6 Application of temperature sensing and dynamic strain monitoring to subsea cable technology (DTS & DTSS) Richard Kluth; Sensornet, Elstree, Hertfordshire, UK Roman Svoma, Leigh Williams; PowerSure Technology, Bexleyheath, London, UK

Page 27: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 27 / 29

SSSEEESSSSSSIIIOOONNN BBB...999::: DDDEEESSSIIIGGGNNN (((222))) Wednesday June 27, 2007 - 11:00 - 12:30 - Room: B

Chairman: R. ROSEVEAR - Southampton Dielectric Consultants (UK) Rapporteur: Ch. MOREAU - EDF R&D (France)

B.9.1 Sensitivity of PD inception to change of electrical design in polymeric insulated cable systems Nico van Schaik, Peter van der Wielen; KEMA-TDT, Arnhem, The Netherlands Tadeusz Czaszejko; Monash University, Clayton, Australia

B.9.2 Tools for understanding the thermo-electrical behaviour of XLPE insulation in power cables and accessories Séverine Le Roy, Fulbert Baudoin, Gilbert Teyssedre, Christian Laurent; Université Paul Sabatier, Toulouse, France L.A. Dissado; University of Leicester, UK Gian Carlo Montanari; University of Bologna, Italy

B.9.3 Improvements in superabsorbent water blocking materials for new power cable applications Stephen Czupryna, Jacques Everaere; Geca Tapes b.v., Bailleul, France Michel Delattre; PGI Nordlys, Bailleul, France

B.9.4 Power cable modeling under power electronic converter constraints Yannick Weens, Nadir Idir, Jean-Jacques Franchaud, Robert Bausiere; Université des Sces et Techn. de Lille, France

B.9.5 Longitudinal induction voltage measurement on communication cables running parallel to overhead lines or power cables Dean Sharafi; Western Power Corporation, Perth, Australia Ulrich Klapper; Omicron electronics, Klaus, Austria

B.9.6 K-factor measurement of cables for optimum reliability of distance protection and fault locators Ulrich Klapper; Omicron electronics, Klaus, Austria Lothar Fickert; Technical University of Graz, Austria

B.9.7 Sheath circulating current calculations and measurements of underground power cables Xiaolin Chen, Yonghong Cheng, Kai Wu; Xi'an Jiaotong University, Xi'an, Shaanxi, China

Page 28: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 28 / 29

SSSEEESSSSSSIIIOOONNN AAA...111000::: TTTEEESSSTTTIIINNNGGG MMMEEETTTHHHOOODDDSSS (((222))) Wednesday June 27, 2007 - 14:30 - 16:00 - Room: A

Chairman: J-Y. KOO- HANYANG Univ. (Korea) Rapporteur: P. PENSERINI - EDF R&D (France)

A.10.1 Comparison of different analytical test methods to monitor crosslinking by-products in XLPE insulated cables Annika Smedberg, Jan-Ove Boström; BOREALIS AB, Stenungsund, Sweden Detlef Wald, Rudi Peters; BOREALIS Polymers NV, Mechelen, Belgium

A.10.2 Initiation of electrical trees from defects in XLPE insulation under DC stress Erling Ildstad, Rolf Hegerberg; Norwegian University of Sc.and Tech., Trondheim, Norway Mildrid Selsjord; SINTEF Energy Research, Trondheim, Norway Bjørn Sanden; NEXANS Norway AS, Oslo, Norway Marc Jeroense; ABB Power Systems, Karlskrona, Sweden Jan Erik Larsen; Stattnett SF, Oslo, Norway

A.10.3 New approach to measure conductor temperature during type test Edwin Pultrum, Wouter Sloot, S.A.M. Verhoeven; KEMA, Arnhem, The Netherlands

A.10.4 After-installation testing of HV / EHV extruded cable systems – procedures and experiences Ronald Plath, Ulrich Herrmann; IPH, Berlin, Germany

A.10.5 HV AC testing of super-long cables and gas-insulated lines in factory and on-site Stefan Schierig, Wofgang Hauschild, Peter Coors; TU Dresden, Dresden, Germany

A.10.6 Type testing of a 13.2 kV, 69 MVA TRIAX HTS cable Dag Willén; NKT Cables, Brondby, Denmark

Page 29: Jicable'07 7th International Conference on Power Insulated Cables 07... · 2007. 5. 4. · Jicable'07 7th International Conference on Power Insulated Cables Jicable'07 – Technical

Jicable'07 7th International Conference on Power Insulated Cables

Jicable'07 – Technical Programme - Versailles Congress Center Page 29 / 29

SSSEEESSSSSSIIIOOONNN BBB...111000::: EEECCCOOONNNOOOMMMYYY OOOFFF CCCAAABBBLLLEEE SSSYYYSSSTTTEEEMMMSSS Wednesday June 27, 2007 - 14:30 - 16:00 - Room: B

Chairman: M. de SIQUEIRA CAMPOS ARAÚJO - BRENNAND Energia (Brazil) Rapporteur: Ch. FAVRIE - SYCABEL (France)

B.10.1 Challenges and opportunities of installing HV cable in Australia and Sri Lanka Naveed Rahman, Ken Barber; Olex Australia, Tottenham, Australia

B.10.2 Aluminium conductors in anti-robbery cables João Alves de Paula, Luiz Henrique Rosa, Sidnei Ueda; NEXANS Brasil, São Paulo, Brazil

B.10.3 Design of a 45 circuit duct bank Mark Coates; ERA Technology Ltd, Leatherhead, UK Liam O'Sullivan; EDF Energy Networks, Bexleyheath/Kent, UK

B.10.4 Defect specific diagnostics: economic analysis and reliability modeling Bruce Broussard, Ben Lanz; IMCORP™, Storrs, CT , USA

B.10.5 Cable reliability enhancement by defect-specific diagnostics Matthew S. Mashikian, Bruce Broussard; IMCORP™, Storrs, CT , USA

B.10.6 Barrier optimization algorithm applied to calculation of optimal loading of dissimilar cables in one trench George J. Anders; Kinectrics Inc., Toronto, Canada Wael Moutassam; University of Toronto, Canada

SSSEEESSSSSSIIIOOONNN AAA...111111::: CCCLLLOOOSSSIIINNNGGG SSSEEESSSSSSIIIOOONNN Wednesday June 27, 2007 - 16:30 - 18:00 - Room: A

The closing session will include:

Round Table: Long lengths EHV electrical links by AC insulated power cables in the world

JICABLE'07 Award and closing of the conference.