8
Thermo Scientific ISQ EC single quadrupole mass spectrometer Join the mass movement towards mass spectrometry

Join the mass movement towards mass spectrometry · Join the mass movement towards mass spectrometry. Despite the benefits of incorporating mass spectrometry (MS) into your analyses,

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Join the mass movement towards mass spectrometry · Join the mass movement towards mass spectrometry. Despite the benefits of incorporating mass spectrometry (MS) into your analyses,

Thermo Scientific ISQ EC single quadrupole mass spectrometer

Join the mass movement towards mass spectrometry

Page 2: Join the mass movement towards mass spectrometry · Join the mass movement towards mass spectrometry. Despite the benefits of incorporating mass spectrometry (MS) into your analyses,

Despite the benefits of incorporating mass spectrometry (MS) into your analyses, we know MS can seem complex. That is why we designed the Thermo Scientific™ ISQ™ EC single quadrupole mass spectrometer with ease of use in mind. The ISQ EC mass spectrometer not only seamlessly integrates with your ion chromatograph (IC) or liquid chromatograph (LC), but also sets new standards for user friendliness.

Gain greater insights from your sampleCoupling ion or liquid chromatography to mass spectrometry (MS), allows you to gain greater insights from your samples. Adding MS gives you:

• Higher sensitivity and more accurate quantitation

• Chromatographic peak mass confirmation, reducing the likelihood of false negatives and positives

Embrace the power of mass spectrometry

Achieving a comprehensive understanding of the samples you

analyze is always a challenge. At Thermo Fisher Scientific, we

believe the easier we can make the journey from sample to

knowledge, the more information you will have to succeed

with your analyses.

Page 3: Join the mass movement towards mass spectrometry · Join the mass movement towards mass spectrometry. Despite the benefits of incorporating mass spectrometry (MS) into your analyses,

Resolve complexity Analyze simple and complex matrices with confidence based on the superior robustness of the ISQ EC mass spectrometer. This single quadrupole MS offers:

• Improved resolution of analytes in complex matrices

• Identification of co-eluting peaks

Easily master MSThe seamless integration of the ISQ EC mass spectrometer with your IC or LC system allows you to focus on successfully using the system with:

• Integrated tools to to help you quickly learn the MS system

• Thermo Scientific™ Chromeleon™ Chromatography Data System (CDS) software for analysis, including embedded control of the ISQ EC mass spectrometer

Page 4: Join the mass movement towards mass spectrometry · Join the mass movement towards mass spectrometry. Despite the benefits of incorporating mass spectrometry (MS) into your analyses,

4

The ISQ EC mass spectrometer offers improved low-mass sensitivity for

detecting perchlorate in municipal drinking water. This sensitivity is not possible

using IC with conductivity detection (CD) alone. Additionally, no organic solvent

make-up is required.

Compared to IC with conductivity detection alone, the ISQ EC MS provides better

selectivity by resolving co-eluting peaks using mass-to-charge (m/z) ratio. In this

example, succinate (m/z 117) and malate (m/z 133) peaks are co-eluting in an animal

feed sample. These peaks are resolved in single ion monitoring (SIM) mode.

Ion Chromatography – Mass Spectrometry (IC-MS)

0.040

0.026

µS-m

in

Suppressed Conductivity

1700

800

Coun

ts-m

in

ISQ EC MS, SIM

ISQ EC MS, SIM 2000

1650

Coun

ts-m

in

Perchlorate, m/z 99

6.7 16 Minutes

Perchlorate, m/z 101

Perchlorate?

Inte

tens

ity (c

ount

s)Re

spon

se (µ

S)

0 2 4 6 8 10 11

0

350,000

Minutes

0

300,000

0

250,0000

50000

120,000-1.50

-0.40

RT: 3.58 - pyruvateRT: 4.79 - Succinate/Malate

Suppressed Conductivity Detection

Pyruvate SIM 87ISQ EC

Succinate SIM 117ISQ EC

Malate SIM 133ISQ EC

Citrate SIM 191ISQ EC

RT: 9.46 - Citrate

RT: 3.58 - pyruvate - Area: 16652

RT: 4.77 - Succinate - Area: 34718

RT: 4.79 - Malate - Area: 42018

RT: 9.46 - Citrate - Area: 55471

Better sensitivity

Coelution resolved in the MS dimension

in the MS dimension

Better peak shape = better auto quantitation

0 2 4 6 8 10 11

0

350,000

minute

0

300,000

min

Inte

tens

ity(c

ount

s)

0

250,000

0

50000

120,000-1.50

-0.40

Pyruvate SIM 87

Succinate SIM 117

Malate SIM 133

Citrate SIM 191

Res

pons

e (µ

S)

Standard mix at 0.5 mg/L level –Integrion Conduc�vity Detector

ISQ EC

ISQ EC

ISQ EC

ISQ EC

Coelution resolved

in the MS dimension

Better Sensitivity

Better Peak Shape == Better Auto Quantitation

Integrion Conductivity Detector

Standard mix at 0.5 mg/L level

Gain greater insights from your sample

The power of MS enhances your chromatography analyses

with higher sensitivity and improved selectivity for analytes of

interest. The ISQ EC MS achieves limits of detection (LOD) in the

single-digit-parts-per-billion (ppb) range. For analyses requiring

peak confirmation, the ISQ EC MS provides mass-to-charge

(m/z) confirmation for separated compounds to give you

confidence in your results.

Page 5: Join the mass movement towards mass spectrometry · Join the mass movement towards mass spectrometry. Despite the benefits of incorporating mass spectrometry (MS) into your analyses,

5

Liquid Chromatography – Mass Spectrometry (LC-MS)

SIM 520.2 m/z SIM 136.1 m/z SIM 288.1 m/z SIM 248.1 m/z

Full Scan 120 – 600 m/z

Adenine Tenofovir

Emtricitabin Tenofovir disoproxil

Minutes

Inte

nsity

(cou

nts

* m

in)

Base Peak Chromatogram

When detecting impurities for both routine and demanding pharmaceutical assays, MS provides reliable and robust quantification that complements traditional UV/Vis

data. The ISQ EC MS can perform targeted and untargeted impurity profiling at the same time by employing Full Scan and SIM scans in the same run. This will ensure

you do not miss a single peak.

Page 6: Join the mass movement towards mass spectrometry · Join the mass movement towards mass spectrometry. Despite the benefits of incorporating mass spectrometry (MS) into your analyses,

0

200

400

600

800

1000

1200

0 50 100 150 200 250 300 350 400

Peak

Are

a

Injection Number

Reserpine Peak Area Robustness

Between days

Sprayer needle change in the MS interface

Total RSD = 3.95%, 1 ppb, 10 pg on-column

The ISQ EC MS demonstrates reliable day-to-day, low-concentration reserpine peak

area reproducibility, even while simultaneously performing routine maintenance.

The ISQ EC features an all new orthogonal ion source specifically designed to address

challenging sample matrices. The ion source provides longer, uninterrupted operation

by saving time spent on maintenance.

Resolve complexity The ISQ EC mass spectrometer enables the analysis of a variety

of complex sample matrices with unparalleled robustness.

Page 7: Join the mass movement towards mass spectrometry · Join the mass movement towards mass spectrometry. Despite the benefits of incorporating mass spectrometry (MS) into your analyses,

7

Master MS

Quickly access expert experiment-based knowledge built into the ISQ EC MS interface to obtain quality results fast. This interface was designed with unique algorithms and two modes. Easy Mode focuses your MS analysis using basic chemical parameters. Advanced Mode provides customizable parameters to enhance the quality of your results (e.g., sensitivity, peak confirmation, robustness).

Gain more time for data analysis

The first step to better understanding your sample is to analyze and report your IC-MS and/or LC-MS data.

The Chromeleon CDS software simplifies this process with embedded control of the ISQ EC MS system. The software is not only easy to use, but also regulatory compliant.

In addition:

• Quickly access detailed method information from the Thermo Scientific™ AppsLab Library of Analytical Applications, an online repository

• The Thermo Scientific™ Chromeleon™ XPS Open Access user interface enhances your user experience with simple, walk-up workflows

• An Autotune feature automates instrument calibration. Moreover, the Autotune can be scheduled as part of your workflow, at any time and from any place

The intuitive ion source technology tool, incorporated into Easy Mode, helps you select

optimal MS conditions based on three parameters.

Step 1. Select your eWorkflow and instrument

Step 2. Create your sample list

Step 3. Submit your sequence

Step 4. Get your custom analysis report, either printed or via email

Easily master MS The faster you develop your MS skills, the closer you move

to expanding your sample knowledge. With the ISQ EC mass

spectrometer, both novice and advanced users can easily master MS.

Page 8: Join the mass movement towards mass spectrometry · Join the mass movement towards mass spectrometry. Despite the benefits of incorporating mass spectrometry (MS) into your analyses,

Find out more at thermofisher.com/ISQEC

© 2017 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. This information is presented as an example of the capabilities of Thermo Fisher Scientific Inc. products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. BR72397-EN 0617S

Your trusted MS partner Thermo Fisher Scientific offers a comprehensive portfolio of mass spectrometry instruments to help you solve complex analytical challenges. Choose from our single quadrupole, triple quadrupole and high resolution accurate mass (HRAM) hybrid quadrupole-Orbitrap™ MS instruments. We also provide a single point of contact for application, technical and integrated lab service support. Let our expertise complement yours along the journey from sample to knowledge.

Thermo Scientific™ Orbitrap Fusion™

Tribrid™ Mass Spectrometer

Thermo Scientific™ TSQ Altis™

Triple Quadrupole Mass Spectrometer

Thermo Scientific™ TSQ Quantis™

Triple Quadrupole Mass Spectrometer

ISQ EC Single Quadrupole

Mass Spectrometer

Thermo Scientific™ Q Exactive™

Hybrid Quadrupole-Orbitrap™

Mass Spectrometer