16
JPD-100A Fetal Doppler Features The ultrasound dosage is under 50% of the national ultrasonic power standard. Compact and portable design provides a convenient use and carrying. LCD displays the fetal heart rate. Built-in Loud speaker gives more clearly and loudly. With automatic shutdown function when the probe not working within one minute. With rechargeable batteries, enables to work continuously for over 10 hours after full charge Monitor 9 weeks fetuss blood wall pulsate with the high sensibility probe. Three calculation modes to calculate fetal heart rate: instant, 10 second average and manual Specification Ultrasound probe: solid and durable, anti-shock, anti-falling down Ultrasound frequency: 3 MHz ±3Ultrasound intensity: <2.5Mw/cm2 FHR Scope:50BPM~210BPM Power: AC 220V 50Hz,DC 7.2V.on requestSize: 240mm*60mm*15mm Weight: Main body 0.12kg Temperature: 5- 40Humidity: 0-85% 1

JPD-100A Fetal Doppler - TradeKeyimg.tradekey.com/images/uploadedimages/brochures/2/5/...JPD-100A Fetal Doppler Features The ultrasound dosage is under 50% of the national ultrasonic

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: JPD-100A Fetal Doppler - TradeKeyimg.tradekey.com/images/uploadedimages/brochures/2/5/...JPD-100A Fetal Doppler Features The ultrasound dosage is under 50% of the national ultrasonic

JPD-100A Fetal Doppler

Features● The ultrasound dosage is under 50% of the national

ultrasonic power standard.● Compact and portable design provides a convenient use

and carrying. ● LCD displays the fetal heart rate. ● Built-in Loud speaker gives more clearly and loudly. ● With automatic shutdown function when the probe not

working within one minute.● With rechargeable batteries, enables to work

continuously for over 10 hours after full charge ● Monitor 9 weeks fetus’s blood wall pulsate with the high

sensibility probe.● Three calculation modes to calculate fetal heart rate:

instant, 10 second average and manual

SpecificationUltrasound probe: solid and durable, anti-shock,

anti-falling downUltrasound frequency: 3 MHz ±3%

Ultrasound intensity: <2.5Mw/cm2

FHR Scope:50BPM~210BPM

Power: AC 220V 50Hz,DC 7.2V.(on request)

Size: 240mm*60mm*15mm

Weight: Main body 0.12kg

Temperature: 5℃ - 40℃

Humidity: 0-85%

1

Page 2: JPD-100A Fetal Doppler - TradeKeyimg.tradekey.com/images/uploadedimages/brochures/2/5/...JPD-100A Fetal Doppler Features The ultrasound dosage is under 50% of the national ultrasonic

JPD-100BFetal Doppler

Features● The ultrasound dosage is under 50% of the national ultrasonic power standard.● Light Weight,handset,portable● Large LCD display with blue backlight● Built-in loudspeaker,more clearly & loudly● Support 2Mhz,2.5Mhz,3Mhz waterproof probe Accurate FHR detection with clear sound● Monitor 12 weeks above unborn baby’s blood wall pulsate.

SpecificationUltrasound probe: solid and durable, anti-shock, anti-falling down

Ultrasound frequency: 2/2.5/3 MHz ±3%

Ultrasound intensity: <2.5Mw/cm2

Power: AC 220V 50Hz,Built in 9.6V nickel-hydrogen rechargeable batteries)

Weight: Main body 0.25kg

Temperature: 5℃-40℃

Humidity: 0-85%

2

Page 3: JPD-100A Fetal Doppler - TradeKeyimg.tradekey.com/images/uploadedimages/brochures/2/5/...JPD-100A Fetal Doppler Features The ultrasound dosage is under 50% of the national ultrasonic

JPD-100TUltrasound fetal doppler

(Time display)

FeaturesSafe: ultrasound dosage is under the safe standard 50% of

National standardDurable: Huge capacity battery, work more than 12 hours after

full chargeConvenience: The structure design of the equipment accords

with human engineering. Single key to control the operation of all functions. Setting the main unit on the base is not only for automatic charge, but also for overvoltage protection function. Sensitivity: Monitor 9 weeks fetus's blood wall pulsate with the

high sensibility probe.Probe: According to different weekly diagram of pregnant, 2.2

MHz or 3.3 MHz can be selected.Speaker: Quality "Sanyo" speaker take more clearly and loudly

SpecificationUltrasound probe: solid and durable, anti-shock, anti-falling down

Ultrasound frequency: 3.3 MHz or 2.2 MHz ±3%

Ultrasound intensity: <2.5Mw/CM2

Display: high light LED display the time of operation

Power: AC 220V 50Hz,DC 18V.(on request)

Rechargeable battery: 1100Mah( can work more than 12 hours

continuously)Dimension:240mm×160mm×115mm

Weight: Main body: 1.12 kg, charger:0.64 kg

3

Page 4: JPD-100A Fetal Doppler - TradeKeyimg.tradekey.com/images/uploadedimages/brochures/2/5/...JPD-100A Fetal Doppler Features The ultrasound dosage is under 50% of the national ultrasonic

FeaturesSafe: ultrasound dosage is under the safe standard 50% of

National standardDurable: Huge capacity battery, work more than 12 hours after full

chargeConvenience:The structure design of the equipment accords

with human engineering. Single key to control the operation of all functions. Setting the main unit on the base is not only for automatic charge, but also for overvoltage protection function. Sensitivity: Monitor 9 weeks fetus’s blood wall pulsate with the

high sensibility probe.Probe: According to different weekly diagram of pregnant, 2.2 MHz

or 3.3 MHz can be selected.Speaker: Quality “Sanyo” speaker take more clearly and loudly

SpecificationUltrasound probe: solid and durable, anti-shock, anti-falling down

Ultrasound frequency: 3.3 MHz or 2.2 MHz ±3%

Ultrasound intensity: <2.5Mw/CM2

Display: high light LED display real-time FHR

FHR Scope:60BPM-210BPM

Power: AC 220V 50Hz,DC 18V.(on request)

Rechargeable battery: 1100Mah( can work more than 12 hours

continuously)Dimension:240mm×160mm×115mm

Weight: Main body: 1.12 kg, charger:0.64 kg

JPD-200CDigital Fetal Doppler

(Digital)

4

Page 5: JPD-100A Fetal Doppler - TradeKeyimg.tradekey.com/images/uploadedimages/brochures/2/5/...JPD-100A Fetal Doppler Features The ultrasound dosage is under 50% of the national ultrasonic

JPD-300AFetal Monitor

Features● Probe: Solid and durable, anti-shock and anti-falling down.● Multi-fetus: Single fetus,twin fetus,tri-fetus are optional.● Multi-parameter: Real-time Maternal SPO2 and NIBP monitor.● Patent: Special fetus awaking function within FHR probe.● Three to one design: Special three to one design among FHR

probe, TOCO probe, fetal movement marker, avoid twisting● Quality speaker take more clearly and loudly● Operate and control mutually with center monitor.

SpecificationUltrasound: Multi wafer, wide wave-beam.

Ultrasound frequency: 1.5MHz+-3%

Ultrasound intensity: <5mW/cm2

TOCO transducer: external transducer

FHR range: 30-210bpm

TOCO range: 0-100 (relative unit)

Power: AC 220V 50Hz

Paper: 112mm thermal

Weight: 3.65KG

Size: 340mm X 310mm X 125mm

Working condition: Temperature 10℃-45℃

Humidity 10-80%

5

Page 6: JPD-100A Fetal Doppler - TradeKeyimg.tradekey.com/images/uploadedimages/brochures/2/5/...JPD-100A Fetal Doppler Features The ultrasound dosage is under 50% of the national ultrasonic

JPD-100S、JPD-100S3、JPD-100S4

Home Care Fetal Doppler Angelsounds

Applicable for:Pregnant women with minimum 16 weeks pregnancy

TipsStrengthening fetal home monitoring is required for the elderly lying-in women or the women experienced abortion and misbirth. Use of Angelsounds Ultrasonic Monitor enables a real time learning of fetus and a safe growing environment for fetus.

Main functionsAngelsounds Ultrasonic Fetal Heartbeat Monitor provides conveniences for pregnant women and family members to listen to the heartbeat of fetus at home, fills in the blank of fetal home monitoring and enables parents a real time learning of fetal safe status.

Other functions Angelsounds Ultrasonic Fetal Heartbeat Monitor stores music for fetus (generation Ⅲ, Ⅳ) with the effect of pushing fetus intellectual development. Angelsounds Ultrasonic Fetal Heartbeat Monitor can record heartbeat of mother during pregnancy and replay the record for

Ultrasound Fetal Doppler as a excellent model of home use fetal monitor products,which will bring happiness and joys for every family.

fetus after birth. It can help the baby to cease crying, adapt the change of environment (Heartbeat of pregnant women is the different from the usual time. Babies frequently cry after birth. This is because the babies can not hear the heartbeat of mother and fail to adapt the change of environment).Angelsounds Ultrasonic Fetal Heartbeat Monitor can record heartbeat of fetus and store it in form of MP3. The “first voice of life” is the most valuable gift for children.

Technical characteristics● Simple operation● Internationally advanced hi-tech patent technology● The test result from the state quality inspection department

shows that ultrasonic level is only 1/10 of the state safety standard free of harm to maternal-infant.

● Passed international CE certification (permit for selling in European market)

Remote monitoringConnecting to the hospital fetal remote monitoring system with telephone line reduces the inconvenience of frequently going to hospital for examination.

JPD-100S JPD-100S3 JPD-100S46

Page 7: JPD-100A Fetal Doppler - TradeKeyimg.tradekey.com/images/uploadedimages/brochures/2/5/...JPD-100A Fetal Doppler Features The ultrasound dosage is under 50% of the national ultrasonic

Home Care Fetal Doppler Angelsounds

Correct method to find fetal heartbeat1. The simplest way is to carefully observe how the doctor finds fetal heartbeat at the hospital and perform repeated listening at

home to determine the position of fetal heartbeat.2. Due to the move of fetus in womb, the position of fetal heartbeat may be different. The general methods to find the position of

fetal heartbeat are as below:a. Before pregnancy of 24 weeks, the fetal heartbeat position is frequent at the middle part right under navel or closely round it. b. After pregnancy of 26 weeks, the best position to listen to the fetal heartbeat is by the side of navel. c. Because quickening is generally the move of fetal hands and legs, when frequent quickening is felt at right side, the fetal

heartbeat is usually at the left side; otherwise, the heartbeat is at the right side. d. Head position and breech position relates with the position of fetal heartbeat. In case head position, the fetal heartbeat is at

left or right side under the navel, while the fetal heartbeat is left or right side above the navel.

Precautions:Normal heartbeat ranges 120~160 per minute. In case that the heartbeat is beyond this range, it is required to go to see the doctor. In case that a sudden fail in finding fetal heartbeat at the original position but quickening can be felt, that means a change of fetal body position. Please carefully find the fetal heartbeat following the methods above. In case of weak fetal heartbeat, please immediately go see the doctor.

1 1 13 34 4

3 2 22

︵16~24w

eek

︵24~32w

eek

︵32~40w

eek

is free from problems. We live a fast paced life with heavy work. It is hard to refuse ineluctable activities and import parties. Now, you can take it easy due to the availability of Angelsounds Ultrasonic Fetal Heartbeat Monitor.The pregnant women who need monitoring mostlyAccording to the diagnostic index of Chinese Obstetrics and Gynecology Association, in case of the followings with you, for your and your fetus health, please perform immediate fetal monitoring at home.(1) Those who are at age under 18 or above 30: women who are over young will easily trouble with dystocia, while those who are over old will trouble with complications of pregnancy induced hypertension, glucosuria, etc.; (2) Those who are with abnormal pregnant record, e.g. abortion, premature delivery, etc.(3) Late pregnancy bleeding, e.g. placenta previa, placental abruption, etc. (4) Abnormal placenta and umbilical cord: The first element for perinatal mortality rate is oxygen deficiency of fetus and new born babies. Fetal oxygen defic8iency caused by umbilical cord accounts for a large proportion. Umbilical cord around neck is the most frequently found among umbilical entanglements at a total occurrence rate nearly 30%. The rate of fetal distress and death caused by umbilical cord around neck is much higher than those of the normal pregnant women. Because various complications affect the function of p0lacenta causing nutrient shortage for fetus, it is a main reason causing fetal oxygen deficiency; (5) Pregnancy induced hypertension syndrome, pregnancy induced glucosuria; pregnancy internal medicine diseases, e.g. severe anemia, virus infection; (6) Contact hazardous substances during pregnancy, e.g. radiation and taking medicines harmful for fetus; (7) Incompatibility of maternal-infant blood type, fetal hemoytic anemia, polyhydramnios, multifetal pregnancy; pregnancy after years’ treatment of sterility; (8) Abnormal fetal position

Prevention of fetal congenital diseasesThe occurrence of cord around neck counts for roughly 30%~40%. Fetal congenital disease or death caused by oxygen deficiency counts for 10‰-15‰. Use of Angelsounds Ultrasonic Fetal Heartbeat Monitor enables an early finding of problems to prevent possible dangers.Real time monitoring keeps fetus sate all the timeNot every pregnant woman knows well that her fetus is risking danger all the time. A simple waist twisting, or even no any movement, brings danger to the fetus. However, the parents know nothing about it. Angelsounds Ultrasonic Fetal Heartbeat Monitor enables you to listen to the fetal heartbeat at home at any time. The heartbeat of fetus shows you that the fetus is healthy.

Self monitoring is recommended in case of the followings1. Accidental event: fall over or striking against Venter; 2. Long term working or fixed body position, nervous; 3. After catching a cold or taking medicines.

Misunderstanding of mother-to-be1、Hospital examination is enoughIn the view ops some pregnant women, regular hospital examination is enough for ensuring the safety of fetus. However,hospital routine examination is performed once a week after the pregnancy of 36 weeks, once for very two weeks during pregnancy of 28~35 weeks, once for every four weeks before the pregnancy of 27 weeks. On the other hand, fetal state may be different from time to time. The hospital routine examination can not ensure an early finding of abnormality. Serving as a doctor to be consulted at any time, Angelsounds Ultrasonic Fetal Heartbeat Monitor enables you to timely find problems and solve immediately.2、I am free from the complications, fetal heartbeat monitoring is therefore not necessary for me.Complications are one of the reasons causing troubles to fetus. Free from complications does not mean that the fetus 7

Page 8: JPD-100A Fetal Doppler - TradeKeyimg.tradekey.com/images/uploadedimages/brochures/2/5/...JPD-100A Fetal Doppler Features The ultrasound dosage is under 50% of the national ultrasonic

JPD-300PColor screen Fetal monitor

(Color Screen)

Features● 12.1 high-resolution color TFT LCD display, support plug-in

large-screen CRT display● Standard Configure: FHR,TOCO,Fetal Movement---Marks● Optional twins● Portable, convenient monitor ● Built-in rechargeable battery, AC-DC power supply, without

interruption Monitor● Dynamic save and display the Monitoring information within

48 hours● Both Use lonely or Connect with a Central Monitor network● Support the extension almost for 128 units central monitor

system.● Quality “Sanyo” speaker take more clear and lound

sound. ● usual thermal paper,more economical.

SpecificationFHR:

Ultrasound Probe: 12pcs chip, Multi-wafer,wave-beam,high sensitiveUltrasound frequency: 1MHz±5%Ultrasound intensity: <3mW/cm2FHR range: 30-240bpmResolution:1bpmAccuracy:± 1bpm/±1%TOCO:

TOCO range: 0-100 (relative unit)Resolution:1bpmNon-linear error:≤±5%Fetal Movement:

Button Hand Count( Automatic cumulative number of movements)/Optional auto-countPrinter

50mm usual thermal paper,more economical

8

Page 9: JPD-100A Fetal Doppler - TradeKeyimg.tradekey.com/images/uploadedimages/brochures/2/5/...JPD-100A Fetal Doppler Features The ultrasound dosage is under 50% of the national ultrasonic

JPD-300PFlip Screen Fetal monitor

Features● High brightness 12.1 inch super-thin LCD provides a larger

display area and clearer display effect. ● Standard Configure: FHR,TOCO,Fetal Movement● Optional twins● Chinese/English operation interfaces are available for

option to satisfy your different demands. ● Human-orientated 0~90°rotary screen innovative design

ensures a best view angle from the various angles. ● Five display interfaces in different styles ● High sensibility wide beamwidth 12 wafer 1MHz pulse

Doppler probe. ● With durable monitor probe . ● Built-in 216mm high speed thermal printer with selected

printing widths of 112mm, 150mm and 210mm and adjustable paper type speed.

● With powerful patient information system, supports to enter patient information and with various languages for option. It stores and replays 72-hour all parameter monitoring data.

● Excellent software processing technology including arrhythmia analysis, pacing analysis, S~T segment analysis, respiration oxygenation and drug concentration calculation ensures a fast grasp for the clinical diagnostic auxiliary information.

● Visual display interface and graphic key operation feature simple.

● Used separately, or connected to the central network main unit forming a central monitoring network. A central monitoring system with 128 sets can be formed.

● With automatic alarm function. ● The internal design conception of full module with quality

ECG module, blood oxygen module, engineering control module and power module in the machine benefits a convenience of function expansion, upgrade and maintenance.

● Wall hanging, AC/DC power, built-in large capacity chargeable lithium battery enabling a monitoring over 3 hours.

● With super upgrade function. It chooses self optional twin fetus and automatic quickening function as per your clinical demand, and Fetal mover graph as your opitional.

● It is designed and produced strictly following the certification standard procedure of ISO9001 and 13485 International Quality management System, and that ensures the safety, stability, durability and super reliability of the product.

SpecificationFHR:

Ultrasound Probe: 12pcs chip, Multi-wafer,wave-beam,high sensitiveUltrasound frequency: 1MHz ±5%Ultrasound intensity: <3mW/cm2FHR range: 30-240bpmResolution:1bpmAccuracy:± 1bpm/±1%TOCO:

TOCO range: 0-100 (relative unit)Resolution:1bpmNon-linear error:≤±5%Fetal Movement:

Button Hand Count( Automatic cumulative number of movements)/Optional auto-countPrinter

112,150,210mm usual thermal paper,more economical

(Flip Screen)

9

Page 10: JPD-100A Fetal Doppler - TradeKeyimg.tradekey.com/images/uploadedimages/brochures/2/5/...JPD-100A Fetal Doppler Features The ultrasound dosage is under 50% of the national ultrasonic

FeaturesProbe: Anti-shock and anti-falling down,solid and durable

Patent: Special fetus awaking function with the FHR probe.

(patent technology)Safe: Ultrasound dosage is under 50% of the safe standard.

Convenient: Meeting the requirement of human engineering

design; doctors can use it with no special training requiredEfficience: More advanced zero adjustment of TOCO,

thoroughly avoid trouble during binding TOCO probe.Protable: Small size, convenient for multi bed monitoring and

outside diagnosing.Three to one design: Special three to one design, avoid twisting

among FHR probe, TOCO probe,fetal movement markerTone: Quality “Sanyo” speaker take more clearly and loudly.

Economical: 58mm usual thermal paper, more economical.

SpecificationDisplay: 6 inch LCD screen

Ultrasonic transducer: Nine wafer, wide wave-beam

Ultrasound frequency: 0.8~2.2MHz±0.1%

Ultrasound intensity: <5Mw/cm2

FHR range: 60-210bpm

Accuracy : ± 2bpm/ ± 1%

TOCO transducer: External transducer

TOCO range: 0-100(relative unit)

Weight: 1.65kg

Power: AC 220V 50Hz

Paper: 58mm thermal

Paper feed speed: 1、2、3cm,adjustable

Abnormal Alarm Range: >160bpm,<120bpm

Working condition: Temperature 10-55 Humidity 10-80%

JPD-300PFetal monitor(6Inch LCD)

10

Page 11: JPD-100A Fetal Doppler - TradeKeyimg.tradekey.com/images/uploadedimages/brochures/2/5/...JPD-100A Fetal Doppler Features The ultrasound dosage is under 50% of the national ultrasonic

JPD-600PColor Screen Maternal & Fetal Monitor

(Color Sreen)

Features● 12.1 high-resolution color TFT LCD display, support plug-in

large-screen CRT display● Standard Configure: FHR,TOCO,Fetal Movement, ECG, Spo2,

NIBP, RESP, TEMP, Pulse Rate● Optional twins● Portable, convenient monitor ● Built-in rechargeable battery, AC-DC power supply, without

interruption Monitor● Both Use lonely or Connect with a Central Monitor network● Support the extension almost for 128 units central monitor

system.● Quality “Sanyo” speaker take more clearly and loundly. ● Usual thermal paper,more economical

SpecificationFHR:

Ultrasound Probe: 12pcs chip, Multi-wafer,wave-beam,high sensitiveUltrasound frequency: 1MHz±5%Ultrasound intensity: <3mW/cm2FHR range: 30-240bpmResolution:1bpmAccuracy:± 1bpm/±1%TOCO:

TOCO range: 0-100 (relative unit)Resolution:1Non-linear error:≤±5%Fetal Movement:Button Hand Count( Automatic cumulative number of movements)

NIBP:

Measurement Units:mmHg/Kpa optionalPressure protection: A double security protection software and hardwareWork Mode: Auto,ManualMeasurement intervals: 2-60 minutes set upSurvey: Systolic blood pressure: 60-240 mmHg Average Blood Pressure: 40-200 mmHg Diastolic Blood Pressure: 30-180 mmHg Resolution:1mmHgAccuracy:±3mmHgPulse rate:40-240bpm

SPO2:

Range:70%-99%Resolution:1%Accuracy:±2 Effective digitalPulse Rate:Range:40-240bpmECG:

Range: 30-300bpmAccuracy:±1bpm/±1%Choice:I、II、 III、aVR、aVL、aVF、VScan Speed:12.5mm/s、25mm/s、50mm/sGain choice:x0.25、x0.5、x1、x2Application:Diagnosis,Monitor,SurgeryRESP:

Range:1-99rpmResolution:1rpmAccuracy:±2rpmTEMP:

Range:26℃- 45℃Resolution:0.1℃Accuracy:±0.2%Work environment:Operation Temperature: 5℃- 40℃Relative temperature:≤80%Atmospheric pressure: (86-106)Kpa,32℃- 45℃:±0.1℃ Printer

50mm usual thermal paper,more economical

11

Page 12: JPD-100A Fetal Doppler - TradeKeyimg.tradekey.com/images/uploadedimages/brochures/2/5/...JPD-100A Fetal Doppler Features The ultrasound dosage is under 50% of the national ultrasonic

JPD-600PFlip Screen Maternal

& Fetal monitorFeatures

● High brightness 12.1 inch super-thin LCD provides a larger display area and clearer display effect.

● Standard Configure: FHR,TOCO,Fetal Movement, ECG, Spo2, NIBP, RESP, TEMP, Pulse Rate

● Chinese/English operation interfaces are available for option to satisfy your different demands.

● Human-orientated 0~90°rotary screen innovative design ensures a best view angle from the various angles.

● Five display interfaces in different styles ● High sensibility wide beamwidth 12 wafer 1MHz pulse Doppler probe. ● With durable monitor probe . ● Built-in 216mm high speed thermal printer with selected printing widths of 112mm,

150mm and 210mm and adjustable paper type speed.

● With powerful patient information system, supports to enter patient information and with various languages for option. It stores and replays 72-hour all parameter

monitoring data.

● Excellent software processing technology including arrhythmia analysis, pacing analysis, S~T segment analysis, respiration oxygenation and drug concentration

calculation ensures a fast grasp for the clinical diagnostic auxiliary information.

● Visual display interface and graphic key operation feature simple. ● Used separately, or connected to the central network main unit forming a central

monitoring network. A central monitoring system with 128 sets can be formed.

● With automatic alarm function. ● The internal design conception of full module with quality ECG module, blood oxygen

module, engineering control module and power module in the machine benefits a

convenience of function expansion, upgrade and maintenance.

● Wall hanging, AC/DC power, built-in large capacity chargeable lithium battery enabling a monitoring over 3 hours.

● With super upgrade function. It chooses self optional twin fetus and automatic quickening function as per your clinical demand, and Fetal mover graph as your

opitional.

● It is designed and produced strictly following the certification standard procedure of ISO9001 and 13485 International Quality management System, and that ensures the

safety, stability, durability and super reliability of the product.

SpecificationFHR:Ultrasound Probe: 12pcs chip, Multi-wafer,wave-beam,high sensitiveUltrasound frequency: 1MHz±5%Ultrasound intensity: <3mW/cm2FHR range: 30-240bpmResolution:1bpmAccuracy:± 1bpm/±1%TOCO:TOCO range: 0-100 (relative unit)Resolution:1Non-linear error:≤±5%Fetal Movement:Button Hand Count( Automatic cumulative number of movements)NIBP:Measurement Units:mmHg/Kpa optionalPressure protection: A double security protection software and hardwareWork Mode: Auto,ManualMeasurement intervals: 2-60 minutes set upSurvey: Systolic blood pressure:60-240 mmHg Average Blood Pressure:40-200 mmHg Diastolic Blood Pressure: 30-180 mmHg Resolution:1mmHgAccuracy:±3mmHgPulse rate:40-240bpmSPO2:Range:70%-99%Resolution:1%Accuracy:±2 Effective digitalPulse Rate:Range:40-240bpmECG:Range: 30-300bpmAccuracy:±1bpm/±1%Choice:I、II、 III、aVR、aVL、aVF、VScan Speed:12.5mm/s、25mm/s、50mm/sGain choice:x0.25、x0.5、x1、x2Application:Diagnosis,Monitor,SurgeryRESP:Range:1-99rpmResolution:1rpmAccuracy:±2rpmTEMP:Range:26℃- 45℃Resolution:0.1℃Accuracy:±0.2%Work environment:Operation Temperature: 5℃- 40℃Relative temperature:≤80%Atmospheric pressure: (86-106)Kpa,32℃- 45℃:±0.1℃ Printer112mm,150mm,210mm usual thermal paper opitional,more economical12

Page 13: JPD-100A Fetal Doppler - TradeKeyimg.tradekey.com/images/uploadedimages/brochures/2/5/...JPD-100A Fetal Doppler Features The ultrasound dosage is under 50% of the national ultrasonic

JPD-800AMulti-parameter patient monitor 10.4”TFT

SpecificationECG ECG Cable:5 Leadwires Lead Section Lead I,II,III/AvR,AvL, AvF/Vgain(mm/Mv):1/4, 1/2,1,2,4Frequency response Diagnosis:0.05-100Hz Monitor:0.5-40Hz Surgery:1.0-25Hz Sweep Speed(mm/Sec):6.25,12.5,25,50 Heart Rate range:0-350 bpm Heart Rate accuracy:±1% ST Segment Deviation Analysis:-0.8~+0.8mV ST accuracy: ±0.02mV Non-Invasive Blood Pressure Measurement Type: Adult,Pediatric,Neonatal Meansurement Range: Systolic 4.0-270mmHg Diastolic 20-200mmHg Mean 30-220mmHg Accuracy: ±3mmHg or 2%(choice max) Resolution:1mmHg Protection:over pressure Pulse Oximeter SPO2 measurement range:0-100% Accuracy: ±2% at 70-100%(No specification under 70%) Resolution:1% Pulse measurement range:30-250BPM Accuracy: ±2% or 1BPM(Choice Max) Resolution:1 BPM

Respiration Rate: Measurement Range:0-120 BPM Accuracy: ±1 BPM or 5%(choice max) Resolution:1 BPM CO2: Measurement Range: 0%-10.0%(in Co2 and et CO2) Accuracy: ±2 mmHg(<5% Measurement Value) ±10%(>5% Measurement Value) Response Time:180ms IBP: Channel number:2ch Range:-40-+330mmHg Accuracy: ±4mmHg or ±4%(choice max) Resolution:1mmHg Environment Operation Storage Temperature:5~40 Storage Temperature:-20~70 Relative humidity:≤80% Storage Temperature: ≤95% Temperature: Channel number:2ch Measurement range:25-45 Accuracy: ±0.1 Resolution:0.1 Response time: ≤3 Min Power requirements: Input:98-260V AC,50/60 Hz Consumption: ≤80VA

Features● 10.4 high Brightness FTF LCD ● 1-8 Channel Waveform Display ● 7 Channel ECG Waveform Display;ST Segment

analysis;Arrhythmia Analysis ● Anti-movement and low perfusion SPO2

Measurement ● Pace pulse Detection ● Defibrillation and ESU Protection ● OxyCRG diagram;Drug Dose Calculation ● Blood Dynamics Analysis ● Venous Punch ● Flexible parameter configuration

13

Page 14: JPD-100A Fetal Doppler - TradeKeyimg.tradekey.com/images/uploadedimages/brochures/2/5/...JPD-100A Fetal Doppler Features The ultrasound dosage is under 50% of the national ultrasonic

Features● 12.1 high Brightness FTF LCD ● 1-8 Channel Waveform Display ● 7 Channel ECG Waveform Display;ST Segment

analysis;Arrhythmia Analysis ● Anti-movement and low perfusion SPO2 Measurement ● Pace pulse Detection ● Defibrillation and ESU Protection ● OxyCRG diagram;Drug Dose Calculation ● Blood Dynamics Analysis ● Venous Punch ● Flexible parameter configuration

ECG ECG Cable:5 Leadwires Lead Section Lead I,II,III/AvR,AvL, AvF/Vgain(mm/Mv):1/4, 1/2,1,2,4Frequency response Diagnosis:0.05-100Hz Monitor:0.5-40Hz Surgery:1.0-25Hz Sweep Speed(mm/Sec):6.25,12.5,25,50 Heart Rate range:0-350 bpm Heart Rate accuracy:±1% ST Segment Deviation Analysis:-0.8~+0.8mV ST accuracy: ±0.02mV Non-Invasive Blood Pressure Measurement Type: Adult,Pediatric,Neonatal Meansurement Range: Systolic 4.0-270mmHg Diastolic 20-200mmHg Mean 30-220mmHg Accuracy: ±3mmHg or 2%(choice max) Resolution:1mmHg Protection:over pressure Pulse Oximeter SPO2 measurement range:0-100% Accuracy: ±2% at 70-100%(No specification under 70%) Resolution:1% Pulse measurement range:30-250BPM Accuracy: ±2% or 1BPM(Choice Max) Resolution:1 BPM

Respiration Rate: Measurement Range:0-120 BPM Accuracy: ±1 BPM or 5%(choice max) Resolution:1 BPM CO2: Measurement Range: 0%-10.0%(in Co2 and et CO2) Accuracy: ±2 mmHg(<5% Measurement Value) ±10%(>5% Measurement Value) Response Time:180ms IBP: Channel number:2ch Range:-40-+330mmHg Accuracy: ±4mmHg or ±4%(choice max) Resolution:1mmHg Environment Operation Storage Temperature:5~40 Storage Temperature:-20~70 Relative humidity:≤80% Storage Temperature: ≤95% Temperature: Channel number:2ch Measurement range:25-45 Accuracy: ±0.1 Resolution:0.1 Response time: ≤3 Min Power requirements: Input:98-260V AC,50/60 Hz Consumption: ≤80VA

Multi-parameter patient monitor 12.1”TFT

Specifications

JPD-800B Long Distance Fetal Monitoring system

14

Page 15: JPD-100A Fetal Doppler - TradeKeyimg.tradekey.com/images/uploadedimages/brochures/2/5/...JPD-100A Fetal Doppler Features The ultrasound dosage is under 50% of the national ultrasonic

Labor Room

Delivery Room

Labor Room

Out Patient

Monitor System

Remote Monitoring

JPD-300KLong Distance Fetal Monitoring system

National Key New ProductThis system is composed of hospital monitoring and remote monitoring.Hospital monitoring is to connect the fetal monitor in out-patient department, labor room and delivery room with the central processing unit. It is to observe the fetal monitoring of the whole obstetrical department through the central processing unit. Inter-operation can be performed between the hospital terminal and the main unit. It can monitor 4~128 bedside machines at the same time. Remote monitoring means to transmit fetal heartbeat, fetal heart rate and quickening of the pregnant women through public telephone network to the central processing unit for remote examination performed by physicians. It is classified into general monitoring and special monitoring.General monitoring: it is to find abnormal pregnant women,

and guide the pregnant woman to perform fetal heartbeat record and result inquiry. It is free from answering call by doctor, and thus labor cost is lowered.

Special monitoring: in case of abnormal fetal heartbeat found by auscultation, it is used for further examination, NST fetal monitoring, analysis on fetal heartbeat curve and quickening.

The application of remote monitoring endows a closer link between the doctor and pregnant woman, a longer fetal monitoring time and a larger fetal monitoring space. The combination of general monitoring and special monitoring achieves the goal of “real time monitoring, monitoring per demand” featuring from area to point and general examination incorporating with emphasis examination.

15

Page 16: JPD-100A Fetal Doppler - TradeKeyimg.tradekey.com/images/uploadedimages/brochures/2/5/...JPD-100A Fetal Doppler Features The ultrasound dosage is under 50% of the national ultrasonic

After sales service:We warrants that new equipment to be free from defects in workmanship and materials for a period of 12 months (four months for accessories,six months for Angelsounds) from shipment date under normal use and service. Our obligation under this warranty is limited to repairing, at our option, any part which is upon our examination proves defective.

The following item will not be involved in the warranty:1) Caused by misuse, negligence or accidents;2) Caused by modification or repair by anyone except us or our designated person;3) From which Jumper original serial number label or product identification marks have been altered or removed

Parts will be available for a maximum period of five (5) years after any equipment has been discontinued. Parts shall include all materials, instructions, diagrams and accessories that were furnished with the standard models.

Return and Freight policy:Be sure confirm with our sales before any return, machine or parts, to avoid customs problem.1. Within Warranty: The customer is responsible for freight & insurance charges when the equipment and/or parts is shipped to Jumper or service (this includes custom charges). Jumper is responsible for the freight & insurance charges from Jumper to the customer.2. After Warranty: The customer is responsible for any freight & insurance charges.

Technical Training:Jumper will provide the service training with free to the distributors at Jumper Medical headoffice in Shenzhen only. The traffic & accommodation charge will be on the distributors’account. And jumper provide technical assistance via e-mail, fax or telephone at any working moment.

The equipment should be returned to the following address after proves defective;Company: Shenzhen Jumper Medical Equipment Co.,LtdAddress: 6th Floor, No.6 Bldg., Nanshui Industry Village, 5th Industry Rd., Shenzhen 518067 P.R.China

16