    JS5016 Data Convergence Gateway Operation Guide

    1 12

    In a following part of th is document, we take the following scheme

    diagram, for example:

    1. Firstly get the device IP address---(If you has known the IP address please

    directed skip to the JSNetView operation section)

    JS5016 data aggregation gate supports NMS based on Console serial port. Youcan query the device IP address by connect the Console port on device with a

    computers serial port.

    1.1 Setting up a Console connectionConnect the DB9F end of serial NMScable to the computers serial port and the other RJ45 end connects to theCONSOLE port on the equipments rear panel.

    1.2You can use a variety of terminal software; here we use HyperTerminalin Windows accessories for an example. Click the computer's Start menu,select Programs Accessories communication HyperTerminaloptions

  • 7/26/2019 JS5016 Data Convergence Gateway Operation Guide V1.0

    4/15

    JS5016 Data Convergence Gateway Operation Guide

    2 12

    1.3 Make sure the equipment and the computer has connected properly,and then selects the correct COM number, as shown in the followingfigure

    1.4 Setting the Hyper Terminals parameters, the baud rate set to 115200(baud rate can be modified, the factory default value is 115200bps),and the data bit set to 8, the parity set to None, the stop bit set to1, the data flow control set to None. as shown in the following figure.

  • 7/26/2019 JS5016 Data Convergence Gateway Operation Guide V1.0

    5/15

    JS5016 Data Convergence Gateway Operation Guide

    3 12

    1.5 After the serial port parameters have been set, click OK button toenter the terminal control interface.

    1.6 Press ENTER key, it will appear root login, input user name admin

    and press ENTER key again, it will appear password, the factorydefault password is blank, hit the press key to login the equipmentsCLI operation interface directly. Enter shownet to get the device IPaddress.

    The default IP address is 192.168.1.11.

    2.JSNetView NMS operation and parameters configuration

    2.1To create a device icon, right click on any blank place at the topology interface

    and select New > JS5016.

  • 7/26/2019 JS5016 Data Convergence Gateway Operation Guide V1.0

    6/15

    JS5016 Data Convergence Gateway Operation Guide

    4 12

    2.2Right click on the device icon and select Properties to modify the device

    attribution, modify the IP Address and click OK button.

  • 7/26/2019 JS5016 Data Convergence Gateway Operation Guide V1.0

    7/15

    JS5016 Data Convergence Gateway Operation Guide

    5 12

    2.3 Double click the device icon to enter the device managementinterface.

  • 7/26/2019 JS5016 Data Convergence Gateway Operation Guide V1.0

    8/15

    JS5016 Data Convergence Gateway Operation Guide

    6 12

    2.4 Only need to configure the working clock and leave other

    parameters to default setting. See the parameters configuration of

    System Parameter in the following figure.

    2.5 All the E1 Parameters use the default configuration.

    .

  • 7/26/2019 JS5016 Data Convergence Gateway Operation Guide V1.0

    9/15

    JS5016 Data Convergence Gateway Operation Guide

    7 12

    2.6 Configuring the parameter of HDLC to assign the bandwidth for the two

    JS10Bs.

    2.7 To create a device icon, right click on any blank place at the topology

    interface and select New > JS10B.

    2.8 Connect JS5016 with JS10B.

  • 7/26/2019 JS5016 Data Convergence Gateway Operation Guide V1.0

    10/15

    JS5016 Data Convergence Gateway Operation Guide

    8 12

    2.9 Connect the first JS10Bs icon with the second JS10Bs icon.

    2.10 Set ID for the two JS10B devices.

  • 7/26/2019 JS5016 Data Convergence Gateway Operation Guide V1.0

    11/15

    JS5016 Data Convergence Gateway Operation Guide

    9 12

    2.11 Select network side E1 clock for the first JS10B device.

  • 7/26/2019 JS5016 Data Convergence Gateway Operation Guide V1.0

    12/15

    JS5016 Data Convergence Gateway Operation Guide

    10 12

    2.12 See the configuration of E1 information in the following figure.

    2.13 Assign the bandwidth for the Ethernet port of the first JS10B.

  • 7/26/2019 JS5016 Data Convergence Gateway Operation Guide V1.0

    13/15

    JS5016 Data Convergence Gateway Operation Guide

    11 12

    2.14 The Loop Test dont need to configure.

    2.15 Assign the bandwidth for the Ethernet port of the second JS10B.

  • 7/26/2019 JS5016 Data Convergence Gateway Operation Guide V1.0

    14/15

    JS5016 Data Convergence Gateway Operation Guide

    12 12

    Refer to above steps to realize JSnetview login, JS5016 login, JS10B login , and

    service parameters configuration.

  • 7/26/2019 JS5016 Data Convergence Gateway Operation Guide V1.0

    15/15