- - (2) LAYERS 5/8" TYPE × GYP. BD. EACH SIDE (W.R 5/8" FIRE RESISTIVE WALLBOARD AT WET SlpE OF BATHROOM AND LAUNDRY WALLS) 3-1/2" ACOUSTIC + - BATT INSULATION - 2×4 STUDS e 16 ' O.C. DIMENSIONS TO WALL FACE ARE TO FACE OF SHEATHING r >lMENSIONS TO WALL C.L. ARE TO C.L. OF STUD GA FILE No. WP 4135 GENERIC 2 HOUR FIRE TO 44 STC SOUND GYPSUM WALLBOARD, WOOD STUDS BASE LAYER 5/8" TYPE × GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO EACH SIDE OF 2 × 4 WOOD STUDS 24' O.C. WITH 6D COATED NAILS, 11/8' LONG, Ø.Ø85" SWANK, 1/4" HEADS, 24' O.C. FACE LAYER 5/8" TYPE × GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO EACH SIDE WITH 8p COATED NAILS, 23/8' LONG, Ø.100' SHANK, 1/4' WEADS, 8' O.C. JOINTS STAGGERED 24' EACH LAYER AND SipE. SOUND TESTED WITH STUDS 16' O.C. AND WITH NAILS FOR BASE LAYER SPACED 6' O.C. (LOAD-BEARING) THICKNESS: 8-1/8" APPROX. WEIGHT: 12 PSF FIRE TEST: PM WP 360, 9-21-74 SOUND TEST: NGW 2363, 4-1-10 2-HR SHAFT WALL M SEE BUILDING PLANS FOR LOCATIONS 1-1/2" = l'-Ø' WOOD 3/4" WOOD TRUSSES 042 SmuCMML 24' O.C. MAX. PANELS R-5Ø BATT INSULATION (3) LAYERS 5/8" TYPE × - HAT-SWAPER syg, go4gp RIGlp FURRÍNG CHANNELS 24" (1) LAYER 5/8' TYPE × GYP. BOARD APPRO×lMATE CEILING WEIGHT: 12 PSF FIRE TEST: UL R4Ø24, ØØNK26545, 4-21-Øl, UL DESIGN L556, ULC DESIGN M514 GA FILE NO. RC 2751 GENERIC 2 HOUR FIRE STC UNTESTED WOOD ROOF TRUSSES, GYPSUM WALLBOARD, RIGID FURRING CHANNELS BASE LAYER 5/8" TYPE × GYPSUM WALLBOARD APPLIED AT RIGHT ANGLES TO WOOD ROOF TRUSSES 24" O.C. WITH 1-1/4" TYPE W DRYWALL SCREWS 12' O.C. SECOND LAYER 5/8" TYPE × GYPSUM WALLBOARD APPLIED AT RIGHT ANGLES TO TRUSSES WITH 2" TYPE W DRYWALL SCREWS 12' O.C. SECOND LAYER JOINTS OFFSET 24' FROM BASE LAYER JOINTS. THIRD LAYER 5/8' TYPE × GYPSUM WALLBOARD APPLIED AT RIGHT ANGLES TO TRUSSES WITH 2-1/2' TYPE W DRYWALL SCREWS 12" O.C. THIRD LAYER JOINTS OFFSET 12' FROM SECOND LAYER JOINTS. WAT-SHAPER RIGID FURRING CHANNELS 24" O.C. APPLIED AT RIGHT ANGLES TO JOISTS OVER THIRD LAYER WITH TWO 2-1/2" LONG TYPE W DRYWALL SCREWS AT EACM TRUSS. FACE LAYER 5/8" TYPE × GYPSUM WALLBOARD APPLIED AT RIGHT ANGLES TO FURRING CHANNELS WITH 1-1/8" TYPE S DRYWALL SCREWS 12' O.C. WOOD TRUSSES SUPPORTING 3/4" T4G EDGE WOOD STRUCTURAL PANELS APPLIED AT RIGHT ANGLES TO TRUSSES WITH 8D NAILS 6" O.C. AT JOINTS AND 12" AT INTERMEDIATE JOISTS. APPROPRIATE ROOP COVERING. CEILING PROVIDES TWO-HOUR FIRE-RESISTANCE PROTECTION FOR WOOD FRAMING. 2-HR ROOF / CEILING ASSEMBLY TYPICAL AT SWAFT ROOF/CEILING LOCATIONS 1-1/2' = l'-Ø" 3/8' PLYWOOD OR 1/2' GYPSUM BOARD D DRAFTSTOP PER IBC 711.4 PANELS - SEE ROOF PLAN FOR LOCATIONS R-5Ø BATT INSULATION WOOD (2) LAYERS TRUSSES e 5/8" TYPE × 24' O.C. MAX. GYP. BOARD GA FILE NO. RC 26Ø2 GENERIC 1 WOUR FIRE STC UNTESTED WOOD TRUSSES, GYPSUM WALLBOARD BASE LAYER 5/8" TYPE × GYPSUM WALLBOARD APPLIED AT RIGHT ANGLES TO WOOD ROOP TRUSSES 24" O.C. WITH 1-1/4" TYPE W OR S DRYWALL SCREWS 24' O.C. FACE LAYER 5/8" TYPE × GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO TRUSSES WITH 1-1/8' TYPE W OR S DRYWALL SCREWS 12" O.C. AT JOINTS AND INTERMEDIATE TRUSSES AND 1-1/2' TYPE G DRYWALL SCREWS 12' O.C. PLACED 2" BACK ON EITHER SIDE OF END JOINTS. WOOD TRUSSES SUPPORTING 1/2' WOOD STRUCTURAL PANELS APPLIED AT RIGHT ANGLES TO TRUSSES WITH 8D NAILS. APPROPRIATE ROOF COVERING. APPRo×lMATE CEILING WEIGHT: 5 PSF FIRE TEST: FM FC 112, 2-25-12, ITS, 8-6-98 1-WR ROOF / CEILING ASSEMBLY K TYPICAL THROUGHOUT l-1/2" = l'-Ø' ACOUSTIC MAT PER SPEC 3/4' GYP-CRETE TOPPING 23/32" T4G SUBFLOOR (MIN. 1/2' PLYWOOD SUBFLOOR) 2×10 (2) LAYERS JOISTS e 5/8" TYPE × 24" O.C. GYP. BOARD MAX. APPRo×lMATE CEILING WEIGHT: 5 PSF FIRE TEST: FM FC 172, 2-25-12, ITS, 8-6-98 SOUND TEST: ESTIMATED GA FILE NO. FC 54Ø6 GENERlC 1 HOUR FIRE 35 TO 39 STC SOUND WOOD JOISTS, GYPSUM WALLBOARD BASE LAYER 5/8' TYPE × GYPSUM WALLBOARD APPLIED AT RIGHT ANGLES TO 2×10 WOOD JOISTS 24" O.C. WlTH 1-1/4" TYPE W OR S DRYWALL SCREWS 24' O.C. FACE LAYER 5/8" TYPE × GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO JolSTS WITH 1-1/8' TYPE W OR S DRYWALL SCREWS 12' O.C. AT JOINTS AND INTERMEDIATE JolSTS AND l-1/2" TYPE G DRYWALL SCREWS 12' O.C. PLACED 2" BACK ON EITHER SIDE OF END JOINTS. JOINTS OFFSET 24' FROM BASE LAYER JOINTS. WOOD JOISTS SUPPORTING 1/2" PLYWOOD WITH EXTERIOR GLUE APPLIED AT RIGHT ANGLES TO JOISTS WITH 8D NAILS. CEILING PROVlpES ONE HOUR FIRE RESISTANCE PROTECTION FOR FRAMING, INCLUplNG TRUSSES. I (1) LAYER 5/8" TYPE × GYP. i y BD. ON INTERIOR SIDE O (W.R. 5/8" 'AQUA-TOUGH' FIRE | @ RESISTlvE WALLBOARD AT WET SIDE OF BATHROOM AND LAUNDRY WALLS) 2×4 STUDS (U.N.Ø) e 16' O.C.- SEE PLANS KRAFT-FACED BATT INSULATION- SEE SPEC STCR. PANEL AT SWEAR WALLS PER STRUCT. - 'QUIETBRACE" SHEATHING ELSEWWERE CEMENTITIOUS SIDING OR STONE VENEER PER ELEVATIONS DIMENSIONS IN PLAN ARE TO FACE OF STUD 042 PROVIDE TYPICAL VAPOR BARRIERS, AIR 1-WR FLOOR / CEILING ASSEMBLY INFILTRATION BARRIERS AND EXTERIOR CLApplNG PER ARCHITECTURAL DRAWINGS TYPICAL AT CORRIDORS 1-1/2" = l'-Ø' p ACOUSTIC MAT PER SPEC 23/32', C-D or SWEATWING, WD. 3/4" GYP-CRETE STRUCTURAL PANELS TOPPING 3-1/2" ACOUSTic BATTA WOOD PROPRIETARY TRUSSES GYPSUM e 24" O.C. BOARD MAX. - DRAFTSTOP RES. CHANNELS PER IBC e 12' O.C. 117.3 AMERICAN 5/8" 'FIREBLOC" GYPSUM Co. TYPE C BPB AMERICA 5/8" 'PRO ROC" TYPE C INC. GYPSUM PANELS G-P GYPSUM 5/8" "TOUGW-ROCK" 'FIREGUARD' C LAFARGE NORTH 5/8" 'FIRECHECK" AMERICA INC. TYPE C PABCO GYPSUM 5/8" 'FLAME CURB' SUPER "C" TYPE C TEMPLE-lNLAND 5/8" TG-C FOREST PRODUCTS CORPORATION UNITED STATES 5/8" 'SHEETROCK' BRAND GYPSUM GYPSUM PANELS COMPANY 'FIRECODE' C CORE GA FILE NO. FC 5515 PROPRIETARY 1 HOUR FIRE STC UNTESTED WOOD TRUSSES, GYPSUM WALLBOARD ONE LAYER 5/8' PROPRIETARY TYPE × GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO RIGID FURRING CHANNELS 24" O.C. WITH l' TYPE S DRYWALL SCREWS 12' O.C. AND LOCATED A MINIMUM OF 1-1/2' FROM JOINTS. GYPSUM BOARD END JOINTS LOCATER MlpWAY BETWEEN CONTINUOUS CHANNELS AND ATTACHER TO ADDITIONAL PIECES OF CHANNEL 60" LONG WITH SCREWS 12" O.C. RIGlp FURRING CHANNELS APPLIED AT RIGHT ANGLES TO 12" DEEP PARALLEL CHORD WOOD TRUSSES 24' O.C. WITH DOUBLE STRAND, 18 GAGE GALVANIZED STEEL WIRE TIES 48' O.C. WOOD TRUSSES SUPPORTING 3/4" NOMINAL INTERIOR PLYWOOD WITH EXTERIOR GLUE, T4G EDGES, APPLIED AT RIGHT ANGLES TO TRUSSES WITH CONSTRUCTION ADMESlvE AND 6d RING SHANK NAILS 12' O.C. ADHESivE APPLIED TO EACH TOP CHORD AND GROOVED EDGES OF PLYWOOD. END JOINTS STAGGERED 48". CONSULT GYPSUM BOARD MANUFACTURER FOR TRUSS DETAILS. APPRO×lMATE CEILING WEIGHT: 3 PSF FIRE TEST: UL R9500-1, 80NK15492 2-2-81, UL R2111-61, 8-18-87 UL DESIGN L528 1-HR EXTERIOR WALL TYPICAL AT ALL EXTERIOR WALLS (2) LAYERS 5/8' TYPE × GYP. BD. EA. SlpE (FACE LAYER WR 5/8' 'AQUATOUGH' FIRE RESIST. WALLBOARD AT WET SIDE OF BATHROOM AND LAUNDRY WALLS) - - - 1" AIR SPACE 3-1/2" ACOUSTIC BATT - |NSULATION, ONE SIDE ONLY 2×4 STUDS e 16' O.C. EACH SIDE FIREBLOCK PER IBC 711.2 AT 10'-Ø' WORIZ. MAX. WITH 1/2" GYP. BD. (ALT: GLASS FIBER BATTS PER IBC 711.2.1.1) DIMENSIONS IN PLAN ARE TO C.L. OF AIR SPACE THICKNESS: 10-3/4' APPROX. WEIGHT: 13 PSF FIRE TEST: SEE WP 4135 (FM WP 360, 9-21-14) SOUND TEST: NGC 3Ø56,4-1-70) 1. WOOD STUDS- NOM. 2×4 SPACED 16" O.C. WITH TWO 2×4 TOP AND ONE 2×4 BOTTOM PLATES. STupS LATERALLY-BRACED BY WOOD STRUCTURAL PANEL SWEATHING (ITEM B) AND EFFECTIVELY FIRE STOPPED AT TOP AND BOTTOM OF WALL. 2. WALLBOARD, GYPSUM* - ANY CLASSIFIED 5/8" THICK, 4' WIDE, APPLIED VERTICALLY AND NAILED TO STUDS AND BEARING PLATES 7" O.C. WITH 6d CEMENT-COATED NAILS, 1-1/8' LONG WITH 1/4" DIA. WEAD. SEE WALLBOARD, GYPSUM (CKNX) CATEGORY FOR NAMES OF CLASSIFIED COMPANIES. 3. JOINTS AND NAILHEADS - (NOT SHOWN) WALLBOARD JOINTS COVERED WITH TAPE AND JOINT COMPOUND. NAIL WEADS COVERED WITH JOINT COMPOUND. 4. BATTS AND BLANKETS* - MINERAL FIBER OR GLASS FIBER BLANKET INSULATION, 3-1/2" THICK, PRESSURE FIT TO FILL WALL CAvlTIES BETWEEN STUDS AND PLATES. MINERAL FIBER INSULATION TO BE UNFACED AND TO WAVE A MIN. DENSITY OF 3 PFC. GLASS FIBER INSULATION TO BE FACED WITH ALUMINUM FOIL OR KRAFT PAPER AND TO WAVE A MIN. DENSITY OF Ø.9 PCF (MIN. R-13 THERMAL INSULATION RATING) SEE BATTS AND BLANKETS (BKNV) CATEGORY IN THE BUILDING MATERIALS DIRECTORY AND BATTS AND BLANKETS (BZJZ) CATEGORY IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF CLASSIFIED COMPANIES. 5. WOOD STRUCTURAL PANEL SWEATHING - MIN. 1/16' THICK, 4' WIDE APA RATED SWEATHING EXPOSURE 1, PLYWOOD OR ORIENTED STRAND BOARD (OSB) PER PS 1, PS 2, OR APA STANDARD PRP-lO8. INSTALLED WITH LONG DIMENSION OF SHEET (STRENGTW A×ls) OR FACE GRAIN OF PLYWOOD PARALLEL WITH OR PERPENDICULAR TO STUDS. VERTICAL JolNTS CENTERED ON STUDS. HORIZONTAL JOINTS BACKED WITH NOM. 2×4 WOOD BLOCKING. ATTACHED TO STUDS ON EXTERIOR SIDE OF WALL WITH 6d CEMENT COATED BOX NAILS SPACED 6" O.C. AT PERIMETER OF PANELS AND 12' O.C. ALONG INTERIOR STUDS. 6. EXTERIOR FACINGS - |NSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. ONE OF THE FOLLOWING EXTERIOR FACINGS IS TO BE APPLIED OF THE SHEATWING: D. CEMENTITIOUS STUCCO - PORTLAND CEMENT OR SYNTHETIC STUCCO SYSTEMS WITH SELF-FURRING METAL LATH OR ADHESivE BASE COAT. THICKNESS FROM 3/8' TO 3/4' DEPENDING ON SYSTEM. E. BRICK VENEER - ANY TYPE OF NOM. 4' WIDE BRICK VENEER. WHEN BRICK VENEER 16 USED, THE RATING IS APPLICABLE WITH EXPOSURE ON EITHER FACE. BRICK VENEER FASTENED WITH CORRUGATED METAL WALL TIES ATTACHED OVER SWEATWING TO WOOD STUDS WITH 8d NAIL PER TIE: TIES SPACED NOT MORE THAN EACH Sl×TH COURSE OF BRICK AND MAX. 32" O.C. WORIZONTALLY. 1" AIR SPACE PROVIDED BETWEEN BRICK VENEER AND SWEATHING. U.L. DESIGN No. U3% EXPOSED TO FIRE ON INTERIOR FACE ONLY l WOUR FIRE STC UNTESTED GYPSUM WALLBOARD, WOOD STUDS, WOOD STRUCTURAL PANEL SWEATWING, CEMENTITIOUS STUCCO OR STONE VENEER NOTES: A. ALL GYSPUM BOARD JOINTS TO BE TAPED AND ALL JOINTS AND FASTENER HEADS TO BE TREATED WITH JOINT COMPOUND. B. IN ADDITION TO R-13 BATT INSULATION, ½" FOAM BOARD MAY BE APPLlED OVER WOOD SUBSTRATE FOR IMPROVED THERMAL RESISTANCE - ONE LAYER GRADE 'D" KRAFT PAPER MAY BE USED UNDER FOAM WHEN PERMITTED BY LOCAL CODE. C. INTERIOR GYPSUM BOARD MAY BE SUBSTITUTED BY 5/8" THICK W.R. GYPSUM BACKING BOARD (ASTM C-630-92) OR GYPSUM VENEER BASE (ASTM C-588-92). D. SEE DATA SHEETS FOR WIND INFILTRATION VALUE. E. ALL FASTENERS TO PENETRATE WOOD FRAMING A MIN. OF l' * - BEARING THE UL CLASSIFICATION MARKING. 1-1/2' = 1'-Ø" GA FILE NO. WP 382Ø GENERIC 2 WOUR FIRE 55 TO 59 STC SOUND (INSUL 1 SIDE) Z GYPSUM LUALLBOARD, WOOD STUDS BASE LAYER 5/8' TYPE × GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO EACH SIDE OF DOUBLE ROW OF 2×4 WOOD STUDS 16' O.C. ON SEPARATE PLATES 1" APART WITH 6p COATED NAILS, 1-1/8" LONG, Ø.Ø85" SHANK, 1/4" HEADS, 24' O.C. FACE LAYER 5/8" TYPE × GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO EACH SIDE WITH 8D COATED NAILS, 2-3/8" LONG, Ø.1ØØ' SHANK, 1/4' WEADS, 8" O.C. JOINTS STAGGERED 16' EACH LAYER AND SIDE. SOUND TESTED WITH 31/2" GLASS FIBER INSULATION STAPLED TO STUDS IN STUD SPACES ON ONE SIDE AND WITH NAILS FOR BASE LAYER SPACED 6" O.C. HORIZONTAL BRACING REQUIRED AT MID-HEIGHT. (LOAD-BEARlNG) >< 7- O O O O (1) LAYER 5/8" TYPE × GYP. BD. EACH SIDE (W.R. 5/8" 'AQUA-TOUGH' FIRE RESISTIVE WALLBOARD AT WET SIDE OF BATHROOM AND LAUNDRY WALLS) 6"x24" UNFACED BATTS RIP BATT AT STUD 2×4 STUDS (U.N.O.) 042 24" O.C. DIMENSIONS TO WALL FACE ARE TO FACE OF STUD DIMENSIONS TO WALL C.L. ARE TO C.L. OF STUD /l / THICKNESS: 5-3/8' APPRO×. WEIGHT: 7 PSF FIRE TEST: BASED ON UL R14196, Ø5NKØ5311, 2 - 15 - Ø5 UL DESIGN U305 SOUND TEST: NRCC TL93-116, 3-98 UL DESIGN No. U34Ø BEARING WALL RAITING - 1 HOUR FINISH RAITING- SEE DESCRIPTION 40 TO 44 STC SOUND (W/O INSUL.) & TO 6//) ATF AnllND flll/ INAlll ) GYPSUM WALLBOARD, MINERAL OR GLASS FIBER INSULATION, WOOD STUDS NOM. 2×4 WOOD STUD ALTERNATING ON OPPOSITE SIDES OF NOM 2×6 WOOD PLATES. SPACED 24" O.C. MAX ON EACM SlpE OF WOOD PLATES, STAGGERING 12" O.C. ON OPPOSITE SIDE. 5/8" THICK GYPSUM WALLBOARD, PAPER OR VINYL PACED WITH BEVELER, SQUARE, TAPERED OR ROUNDED EDGES. WALLBOARD NAILED TO EACH STUD l' O.C. W 6D CEMENT COATED NAILS, 1 7/8" LONG, .Ø915' SWANK DIAM. AND 1/4" DIAM. WEAD. AS AN ALTERNATE, No. 6 BUGLE HEAD DRYWALL SCREWS, 1 1/8" LONG, MAY BE SUBSTITUTED FOR THE 6D CEMENT BOATED NAILS. WHEN USED IN WIDTHS OTHER THAN 48," WALLBOARD TO BE INSTALLED HORIZONTALLY. WALLBOARD JOINTS COVERED WITH TAPE AND JOINT COMPOUND. NAIL HEADS COVERED WITH JOINT COMPOUND. AS AN ALTERNATE, NOM. 3/32' THICK GYPSUM VENEER PLASTER MAY BE APPLIED TO ENTIRE SURFACE OF CLASSIFIED VENEER BASEBOARD. JOINTS REINFORCED. (OPTIONAL) 3 1/2" MAX TWICKNESS GLASS OR MINERAL FIBER BATT INSULATION STAPLED TO STUDS. 1-HR FLOOR / CEILING ASSEMBLY 2-HR SHAFT WALL I-HR CORRIDOR WALL TYPICAL AT ALL APARTMENT FLOORS, UNLESS NOTED OTHERWISE l-1/2" = l'-Ø' SEE BUILDING PLANS FOR LOCATIONS 1-1/2" = 1'-Ø' TYPICAL AT WALLS BETWEEN DWELLING UNITS AND CORRIDORS 1-1/2' = 1'-Ø" (1) LAYER 1/2" GYP. BD. * SUBSTITUTE 5/8" TYPE × GYPSUM BOARD EACH SIDE (*) AT CONTRACTOR'S OPTION (W.R. 1/2' TYPE × WALLBOARD AT WET SIDE OF BATWROOM AND LAUNDRY WALLS) 2×4 STUDS (U.N.0) 042 16' O.C.- SEE PLANS >< DIMENSlONS TO WALL PACE ARE TO FACE OF STUD DIMENSIONS TO WALL C.L. ARE TO C.L. OF STUD (1) LAYER 5/8" TYPE × GYP. BD. EACH SIDE (W.R. 5/8" TYPE × FIRE RESISTlvE WALLBOARD AT WET SIDE OF BATHROOM AND LAUNDRY WALLS) 2×4 STUDS (U.N.0) e 16" O.C.- SEE PLANS DIMENSIONS TO WALL PACE ARE TO FACE OF STUD GA FILE NO. WP 3514 GENERIC 1 WOUR FIRE 35 TO 39 STC SOUND GYPSUM LUALLBOARD, WOOD STUDS ONE LAYER 5/8" TYPE × GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED PARALLEL OR AT RIGHT ANGLES TO EACM SipE OF 2×4 WOOD STUDS 16" O.C. WITH 1-1/4" TYPE W DRYWALL SCREWS AT 12' O.C. JOINTS STAGGERED 16' ON OPPOSITE SIDES. (LOAD BEARING) THICKNESS: 4-3/4" APPROX. WElGHT: 1 PSF FIRE TEST: SWRI Øl-4511-619, 8-19-92 SOUND TEST: (G4W NG-246FT, 1-2-65) DIMENSIONS TO WALL C.L. ARE To C.L. OF STUD (1) LAYER 5/8' TYPE × GYP. BD. EACH SIDE (W.R. 5/8" 'AQUA- TOUGW' FIRE RESISTIVE WALLBOARD AT WET SipE OF BATWROOM AND LAUNDRY WALLS) - - 1" A IR SPACE 3-1/2" ACOUSTIC BATT INSULATION, TYPICAL EACM SIDE 2×4 STUDS (U.N.0) 042 16 " O.C. EACH SIDE- SEE PLANS FIREBLOCK PER IBC 117.2 AT 10'-Ø" WORIZ. MAX. WITH 1/2' GYP. BD. (ALT: GLASS FIBER BATTS PER IBC 111.2.1.1) DIMENSIONS IN PLAN ARE TO C.L. OF AIR SPACE GA FILE NO. WP 337Ø GENERIC 1 HOUR FIRE 45 TO 49 STC SOUND (W/O INSUL.) El TO ½½ ATF. AnllND (Ill/ INAlll ) GYPSUM WALLBOARD, WOOD STUDS ONE LAYER 5/8" TYPE × GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED PARALLEL OR AT RIGHT ANGLES TO EACM SIDE OF DOUBLE ROW OF 2×4 WOOD STUDS 16' O.C. ON SEPARATE PLATES l' APART WITH 6p COATED NAILS, 1-7/8" LONG, Ø.0915' SWANK, 1/4' WEADS, 7" O.C. JOINTS STAGGERED 16' ON OPPOSITE SIDES. WORIZONTAL BRACING REQUIRED AT MID - WEIGHT. (LOADBEARING) THICKNESS: 9-1/2' APPRO×. WEIGHT: 8 PSF FIRE TEST: SEE WP 36Ø5 (UL R1319-4, 6, 6 -17-52 UL R2111-39, 1-2Ø-66 UL R3501-52, 3-15-66 UL DESIGN U3Ø5 ULC DESIGN W3Øl) SOUND TEST: ESTIMATED (WITHOUT INSULATION) NON-RATED INTERIOR NON-BEARING PARTITION 1-HR INTERIOR BEARING WALL I-HR DWELLING UNIT SEPARATION WALL TO BE USED AS APPLICABLE 1-1/2" = 1'-Ø' SEE BUILDING PLANS FOR LOCATIONS 1-1/2" = 1'-Ø' TYPICAL AT WALLS BETWEEN DWELLING UNITS 1-1/2' = 1'-Ø" o < O c OU EE DRAWING RELEASE OG 03-21-14 - PDP Submittal 12-01-14 - 65% Set 01-09-15 - FDP Submittal 01-14-15 - Permit Set 03-20-15 - 98% Review Set 04-03-15 - 98% CD's REVISIONS DATE March 21, 2014 JOB No. 542813 SHEET No. A0.10

K A0 - DowCon, LLC. - Home€¦ ·  · 2015-04-10fire test: pm wp 360, 9-21-74 sound test: ngw 2363, 4-1-10 ... sound test: estimated ga file no. fc 54Ø6 generlc ... sound test:

  • Upload
    haminh

  • View
    217

  • Download
    3

Embed Size (px)

Citation preview

- - (2) LAYERS 5/8"TYPE × GYP. BD.EACH SIDE(W.R 5/8" FIRERESISTIVEWALLBOARD ATWET SlpE OFBATHROOM ANDLAUNDRY WALLS)

3-1/2" ACOUSTIC+ - BATT INSULATION

- 2×4 STUDS e16 ' O.C.

DIMENSIONS TOWALL FACE

ARE TO FACEOF SHEATHING

r >lMENSIONS TOWALL C.L.

ARE TO C.L. OFSTUD

GA FILE No. WP 4135GENERIC

2 HOUR FIRE4Ø TO 44 STC SOUND

GYPSUM WALLBOARD,WOOD STUDS

BASE LAYER 5/8" TYPE × GYPSUMWALLBOARD OR GYPSUM VENEER BASEAPPLIED AT RIGHT ANGLES TO EACH SIDEOF 2 × 4 WOOD STUDS 24' O.C. WITH 6DCOATED NAILS, 11/8' LONG, Ø.Ø85" SWANK, 1/4"HEADS, 24' O.C.FACE LAYER 5/8" TYPE × GYPSUMWALLBOARD OR GYPSUM VENEER BASEAPPLIED AT RIGHT ANGLES TO EACH SIDEWITH 8p COATED NAILS, 23/8' LONG, Ø.100'SHANK, 1/4' WEADS, 8' O.C. JOINTSSTAGGERED 24' EACH LAYER AND SipE.SOUND TESTED WITH STUDS 16' O.C. AND WITHNAILS FOR BASE LAYER SPACED 6' O.C.(LOAD-BEARING)

THICKNESS: 8-1/8"APPROX. WEIGHT: 12 PSFFIRE TEST: PM WP 360, 9-21-74SOUND TEST: NGW 2363, 4-1-10

2-HR SHAFT WALLM

SEE BUILDING PLANS FOR LOCATIONS 1-1/2" = l'-Ø'

WOOD 3/4" WOODTRUSSES �042 SmuCMML

24' O.C. MAX. PANELS

R-5Ø BATTINSULATION

(3) LAYERS5/8" TYPE × -

HAT-SWAPER syg, go4gpRIGlp FURRÍNGCHANNELS 24"

(1) LAYER 5/8'TYPE × GYP.BOARD

APPRO×lMATECEILING WEIGHT: 12 PSFFIRE TEST: UL R4Ø24, ØØNK26545,

4-21-Øl,UL DESIGN L556,ULC DESIGN M514

GA FILE NO. RC 2751GENERIC

2 HOUR FIRESTC UNTESTED

WOOD ROOF TRUSSES,GYPSUM WALLBOARD, RIGID FURRING

CHANNELS

BASE LAYER 5/8" TYPE × GYPSUMWALLBOARD APPLIED AT RIGHT ANGLES TOWOOD ROOF TRUSSES 24" O.C. WITH 1-1/4"TYPE W DRYWALL SCREWS 12' O.C. SECONDLAYER 5/8" TYPE × GYPSUM WALLBOARDAPPLIED AT RIGHT ANGLES TO TRUSSES WITH2" TYPE W DRYWALL SCREWS 12' O.C.SECOND LAYER JOINTS OFFSET 24' FROMBASE LAYER JOINTS. THIRD LAYER 5/8'TYPE × GYPSUM WALLBOARD APPLIED ATRIGHT ANGLES TO TRUSSES WITH 2-1/2' TYPEW DRYWALL SCREWS 12" O.C. THIRD LAYERJOINTS OFFSET 12' FROM SECOND LAYERJOINTS. WAT-SHAPER RIGID FURRINGCHANNELS 24" O.C. APPLIED AT RIGHTANGLES TO JOISTS OVER THIRD LAYER WITHTWO 2-1/2" LONG TYPE W DRYWALL SCREWSAT EACM TRUSS. FACE LAYER 5/8" TYPE ×GYPSUM WALLBOARD APPLIED AT RIGHTANGLES TO FURRING CHANNELS WITH 1-1/8"TYPE S DRYWALL SCREWS 12' O.C. WOODTRUSSES SUPPORTING 3/4" T4G EDGE WOODSTRUCTURAL PANELS APPLIED AT RIGHTANGLES TO TRUSSES WITH 8D NAILS 6" O.C.AT JOINTS AND 12" AT INTERMEDIATEJOISTS. APPROPRIATE ROOP COVERING.

CEILING PROVIDES TWO-HOURFIRE-RESISTANCE PROTECTION FOR WOODFRAMING.

2-HR ROOF / CEILING ASSEMBLYTYPICAL AT SWAFT ROOF/CEILING LOCATIONS 1-1/2' = l'-Ø"

3/8' PLYWOODOR 1/2' GYPSUMBOARD DDRAFTSTOPPER IBC 711.4 PANELS- SEE ROOFPLAN FORLOCATIONS

R-5Ø BATTINSULATION

WOOD (2) LAYERSTRUSSES e 5/8" TYPE ×24' O.C. MAX. GYP. BOARD

GA FILE NO. RC 26Ø2GENERIC

1 WOUR FIRESTC UNTESTED

WOOD TRUSSES,GYPSUM WALLBOARD

BASE LAYER 5/8" TYPE × GYPSUMWALLBOARD APPLIED AT RIGHT ANGLES TOWOOD ROOP TRUSSES 24" O.C. WITH 1-1/4"TYPE W OR S DRYWALL SCREWS 24' O.C.FACE LAYER 5/8" TYPE × GYPSUMWALLBOARD OR GYPSUM VENEER BASEAPPLIED AT RIGHT ANGLES TO TRUSSES WITH1-1/8' TYPE W OR S DRYWALL SCREWS 12"O.C. AT JOINTS AND INTERMEDIATE TRUSSESAND 1-1/2' TYPE G DRYWALL SCREWS 12' O.C.PLACED 2" BACK ON EITHER SIDE OF ENDJOINTS. WOOD TRUSSES SUPPORTING 1/2'WOOD STRUCTURAL PANELS APPLIED ATRIGHT ANGLES TO TRUSSES WITH 8D NAILS.APPROPRIATE ROOF COVERING.

APPRo×lMATECEILING WEIGHT: 5 PSFFIRE TEST: FM FC 112, 2-25-12,

ITS, 8-6-98

1-WR ROOF / CEILING ASSEMBLYK

TYPICAL THROUGHOUT l-1/2" = l'-Ø'

ACOUSTIC MATPER SPEC

3/4' GYP-CRETETOPPING

23/32" T4GSUBFLOOR(MIN. 1/2'PLYWOODSUBFLOOR)

2×10 (2) LAYERSJOISTS e 5/8" TYPE ×24" O.C. GYP. BOARDMAX.

APPRo×lMATECEILING WEIGHT: 5 PSFFIRE TEST: FM FC 172, 2-25-12,

ITS, 8-6-98SOUND TEST: ESTIMATED

GA FILE NO. FC 54Ø6GENERlC

1 HOUR FIRE35 TO 39 STC SOUND

WOOD JOISTS,GYPSUM WALLBOARD

BASE LAYER 5/8' TYPE × GYPSUMWALLBOARD APPLIED AT RIGHT ANGLES TO2×10 WOOD JOISTS 24" O.C. WlTH 1-1/4" TYPE WOR S DRYWALL SCREWS 24' O.C. FACELAYER 5/8" TYPE × GYPSUM WALLBOARDOR GYPSUM VENEER BASE APPLIED ATRIGHT ANGLES TO JolSTS WITH 1-1/8' TYPE WOR S DRYWALL SCREWS 12' O.C. AT JOINTSAND INTERMEDIATE JolSTS AND l-1/2" TYPE GDRYWALL SCREWS 12' O.C. PLACED 2" BACKON EITHER SIDE OF END JOINTS. JOINTSOFFSET 24' FROM BASE LAYER JOINTS.WOOD JOISTS SUPPORTING 1/2" PLYWOODWITH EXTERIOR GLUE APPLIED AT RIGHTANGLES TO JOISTS WITH 8D NAILS.

CEILING PROVlpES ONE HOUR FIRERESISTANCE PROTECTION FOR FRAMING,INCLUplNG TRUSSES.

I

(1) LAYER 5/8" TYPE × GYP.i y BD. ON INTERIOR SIDE

O (W.R. 5/8" 'AQUA-TOUGH' FIRE| @ RESISTlvE WALLBOARD AT

WET SIDE OF BATHROOMAND LAUNDRY WALLS)

2×4 STUDS (U.N.Ø) e 16' O.C.-SEE PLANS

KRAFT-FACED BATTINSULATION- SEE SPEC

STCR. PANEL AT SWEARWALLS PER STRUCT. -'QUIETBRACE" SHEATHINGELSEWWERE

CEMENTITIOUS SIDINGOR STONE VENEERPER ELEVATIONS

DIMENSIONS IN PLANARE TO FACE OF STUD

�042PROVIDE TYPICAL VAPOR BARRIERS, AIR1-WR FLOOR / CEILING ASSEMBLY INFILTRATION BARRIERS AND EXTERIOR

CLApplNG PER ARCHITECTURAL DRAWINGS

TYPICAL AT CORRIDORS 1-1/2" = l'-Ø' p

ACOUSTIC MATPER SPEC

23/32', C-D orSWEATWING, WD. 3/4" GYP-CRETESTRUCTURAL PANELS TOPPING

3-1/2"ACOUSTicBATTA

WOOD PROPRIETARYTRUSSES GYPSUMe 24" O.C. BOARDMAX. -DRAFTSTOP RES. CHANNELSPER IBC e 12' O.C.117.3

AMERICAN 5/8" 'FIREBLOC"GYPSUM Co. TYPE C

BPB AMERICA 5/8" 'PRO ROC" TYPE CINC. GYPSUM PANELS

G-P GYPSUM 5/8" "TOUGW-ROCK"'FIREGUARD' C

LAFARGE NORTH 5/8" 'FIRECHECK"AMERICA INC. TYPE C

PABCO GYPSUM 5/8" 'FLAME CURB'SUPER "C" TYPE C

TEMPLE-lNLAND 5/8" TG-CFOREST PRODUCTSCORPORATION

UNITED STATES 5/8" 'SHEETROCK' BRANDGYPSUM GYPSUM PANELSCOMPANY 'FIRECODE' C CORE

GA FILE NO. FC 5515PROPRIETARY

1 HOUR FIRESTC UNTESTED

WOOD TRUSSES,GYPSUM WALLBOARD

ONE LAYER 5/8' PROPRIETARY TYPE ×GYPSUM WALLBOARD OR GYPSUM VENEERBASE APPLIED AT RIGHT ANGLES TO RIGIDFURRING CHANNELS 24" O.C. WITH l' TYPE SDRYWALL SCREWS 12' O.C. AND LOCATED AMINIMUM OF 1-1/2' FROM JOINTS. GYPSUMBOARD END JOINTS LOCATER MlpWAYBETWEEN CONTINUOUS CHANNELS ANDATTACHER TO ADDITIONAL PIECES OFCHANNEL 60" LONG WITH SCREWS 12" O.C.RIGlp FURRING CHANNELS APPLIED ATRIGHT ANGLES TO 12" DEEP PARALLELCHORD WOOD TRUSSES 24' O.C. WITH DOUBLESTRAND, 18 GAGE GALVANIZED STEEL WIRETIES 48' O.C. WOOD TRUSSES SUPPORTING3/4" NOMINAL INTERIOR PLYWOOD WITHEXTERIOR GLUE, T4G EDGES, APPLIED ATRIGHT ANGLES TO TRUSSES WITHCONSTRUCTION ADMESlvE AND 6d RINGSHANK NAILS 12' O.C. ADHESivE APPLIED TOEACH TOP CHORD AND GROOVED EDGESOF PLYWOOD. END JOINTS STAGGERED 48".

CONSULT GYPSUM BOARD MANUFACTURERFOR TRUSS DETAILS.

APPRO×lMATECEILING WEIGHT: 3 PSFFIRE TEST: UL R9500-1, 80NK15492

2-2-81, UL R2111-61,8-18-87UL DESIGN L528

1-HR EXTERIOR WALLTYPICAL AT ALL EXTERIOR WALLS

(2) LAYERS 5/8' TYPE× GYP. BD. EA. SlpE(FACE LAYER WR 5/8''AQUATOUGH' FIRERESIST. WALLBOARDAT WET SIDE OFBATHROOM ANDLAUNDRY WALLS)

-- - 1" AIR SPACE

3-1/2" ACOUSTIC BATT+¬ - |NSULATION, ONE SIDE

ONLY

2×4 STUDS e 16' O.C.EACH SIDE

FIREBLOCK PER IBC711.2 AT 10'-Ø' WORIZ.MAX. WITH 1/2" GYP.BD. (ALT: GLASSFIBER BATTS PER IBC711.2.1.1)

DIMENSIONS IN PLANARE TO C.L.

OF AIR SPACE

THICKNESS: 10-3/4'APPROX. WEIGHT: 13 PSFFIRE TEST: SEE WP 4135

(FM WP 360, 9-21-14)SOUND TEST: NGC 3Ø56,4-1-70)

1. WOOD STUDS- NOM. 2×4 SPACED 16" O.C. WITH TWO 2×4 TOP AND ONE 2×4 BOTTOM PLATES.STupS LATERALLY-BRACED BY WOOD STRUCTURAL PANEL SWEATHING (ITEM B) ANDEFFECTIVELY FIRE STOPPED AT TOP AND BOTTOM OF WALL.

2. WALLBOARD, GYPSUM* - ANY CLASSIFIED 5/8" THICK, 4' WIDE, APPLIED VERTICALLY ANDNAILED TO STUDS AND BEARING PLATES 7" O.C. WITH 6d CEMENT-COATED NAILS, 1-1/8' LONGWITH 1/4" DIA. WEAD. SEE WALLBOARD, GYPSUM (CKNX) CATEGORY FOR NAMES OF CLASSIFIEDCOMPANIES.

3. JOINTS AND NAILHEADS - (NOT SHOWN) WALLBOARD JOINTS COVERED WITH TAPE AND JOINTCOMPOUND. NAIL WEADS COVERED WITH JOINT COMPOUND.

4. BATTS AND BLANKETS* - MINERAL FIBER OR GLASS FIBER BLANKET INSULATION, 3-1/2" THICK,PRESSURE FIT TO FILL WALL CAvlTIES BETWEEN STUDS AND PLATES. MINERAL FIBER INSULATIONTO BE UNFACED AND TO WAVE A MIN. DENSITY OF 3 PFC. GLASS FIBER INSULATION TO BEFACED WITH ALUMINUM FOIL OR KRAFT PAPER AND TO WAVE A MIN. DENSITY OF Ø.9 PCF (MIN.R-13 THERMAL INSULATION RATING) SEE BATTS AND BLANKETS (BKNV) CATEGORY IN THEBUILDING MATERIALS DIRECTORY AND BATTS AND BLANKETS (BZJZ) CATEGORY IN THE FIRERESISTANCE DIRECTORY FOR NAMES OF CLASSIFIED COMPANIES.

5. WOOD STRUCTURAL PANEL SWEATHING - MIN. 1/16' THICK, 4' WIDE APA RATED SWEATHINGEXPOSURE 1, PLYWOOD OR ORIENTED STRAND BOARD (OSB) PER PS 1, PS 2, OR APASTANDARD PRP-lO8. INSTALLED WITH LONG DIMENSION OF SHEET (STRENGTW A×ls) OR FACEGRAIN OF PLYWOOD PARALLEL WITH OR PERPENDICULAR TO STUDS. VERTICAL JolNTSCENTERED ON STUDS. HORIZONTAL JOINTS BACKED WITH NOM. 2×4 WOOD BLOCKING.ATTACHED TO STUDS ON EXTERIOR SIDE OF WALL WITH 6d CEMENT COATED BOX NAILSSPACED 6" O.C. AT PERIMETER OF PANELS AND 12' O.C. ALONG INTERIOR STUDS.

6. EXTERIOR FACINGS - |NSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATIONINSTRUCTIONS. ONE OF THE FOLLOWING EXTERIOR FACINGS IS TO BE APPLIED OF THESHEATWING:

D. CEMENTITIOUS STUCCO - PORTLAND CEMENT OR SYNTHETIC STUCCO SYSTEMS WITHSELF-FURRING METAL LATH OR ADHESivE BASE COAT. THICKNESS FROM 3/8' TO 3/4'DEPENDING ON SYSTEM.

E. BRICK VENEER - ANY TYPE OF NOM. 4' WIDE BRICK VENEER. WHEN BRICK VENEER 16USED, THE RATING IS APPLICABLE WITH EXPOSURE ON EITHER FACE. BRICK VENEER FASTENEDWITH CORRUGATED METAL WALL TIES ATTACHED OVER SWEATWING TO WOOD STUDS WITH 8dNAIL PER TIE: TIES SPACED NOT MORE THAN EACH Sl×TH COURSE OF BRICK AND MAX. 32" O.C.WORIZONTALLY. 1" AIR SPACE PROVIDED BETWEEN BRICK VENEER AND SWEATHING.

U.L. DESIGN No. U3%EXPOSED TO FIRE ON INTERIOR FACE ONLY

l WOUR FIRESTC UNTESTED

GYPSUM WALLBOARD, WOOD STUDS,WOOD STRUCTURAL PANEL SWEATWING,

CEMENTITIOUS STUCCO OR STONEVENEER

NOTES:A. ALL GYSPUM BOARD JOINTS TO BETAPED AND ALL JOINTS AND FASTENERHEADS TO BE TREATED WITH JOINTCOMPOUND.B. IN ADDITION TO R-13 BATT INSULATION, ½"FOAM BOARD MAY BE APPLlED OVERWOOD SUBSTRATE FOR IMPROVED THERMALRESISTANCE - ONE LAYER GRADE 'D" KRAFTPAPER MAY BE USED UNDER FOAM WHENPERMITTED BY LOCAL CODE.C. INTERIOR GYPSUM BOARD MAY BESUBSTITUTED BY 5/8" THICK W.R. GYPSUMBACKING BOARD (ASTM C-630-92) ORGYPSUM VENEER BASE (ASTM C-588-92).D. SEE DATA SHEETS FOR WINDINFILTRATION VALUE.E. ALL FASTENERS TO PENETRATE WOODFRAMING A MIN. OF l'

* - BEARING THE UL CLASSIFICATIONMARKING.

1-1/2' = 1'-Ø"

GA FILE NO. WP 382ØGENERIC

2 WOUR FIRE55 TO 59 STC SOUND (INSUL 1 SIDE)

Z

GYPSUM LUALLBOARD,WOOD STUDS

BASE LAYER 5/8' TYPE × GYPSUMWALLBOARD OR GYPSUM VENEER BASEAPPLIED AT RIGHT ANGLES TO EACH SIDEOF DOUBLE ROW OF 2×4 WOOD STUDS 16'O.C. ON SEPARATE PLATES 1" APART WITH6p COATED NAILS, 1-1/8" LONG, Ø.Ø85"SHANK, 1/4" HEADS, 24' O.C. FACE LAYER5/8" TYPE × GYPSUM WALLBOARD ORGYPSUM VENEER BASE APPLIED AT RIGHTANGLES TO EACH SIDE WITH 8D COATEDNAILS, 2-3/8" LONG, Ø.1ØØ' SHANK, 1/4'WEADS, 8" O.C.

JOINTS STAGGERED 16' EACH LAYER ANDSIDE. SOUND TESTED WITH 31/2" GLASS FIBERINSULATION STAPLED TO STUDS IN STUDSPACES ON ONE SIDE AND WITH NAILS FORBASE LAYER SPACED 6" O.C. HORIZONTALBRACING REQUIRED AT MID-HEIGHT.(LOAD-BEARlNG)

><

7-

OO

OO

(1) LAYER 5/8" TYPE × GYP.BD. EACH SIDE(W.R. 5/8" 'AQUA-TOUGH' FIRERESISTIVE WALLBOARD ATWET SIDE OF BATHROOMAND LAUNDRY WALLS)

6"x24" UNFACED BATTS

RIP BATT AT STUD

2×4 STUDS (U.N.O.) �04224" O.C.

DIMENSIONS TO WALL FACEARE TO FACE OF STUD

DIMENSIONS TO WALL C.L.ARE TO C.L. OF STUD

/l /

THICKNESS: 5-3/8'APPRO×. WEIGHT: 7 PSFFIRE TEST: BASED ON UL R14196,

Ø5NKØ5311, 2 - 15 - Ø5UL DESIGN U305

SOUND TEST: NRCC TL93-116, 3-98

UL DESIGN No. U34ØBEARING WALL RAITING - 1 HOUR

FINISH RAITING- SEE DESCRIPTION40 TO 44 STC SOUND (W/O INSUL.)& TO 6//) ATF AnllND flll/ INAlll )

GYPSUM WALLBOARD, MINERAL ORGLASS FIBER INSULATION, WOOD

STUDS

NOM. 2×4 WOOD STUD ALTERNATING ONOPPOSITE SIDES OF NOM 2×6 WOOD PLATES.SPACED 24" O.C. MAX ON EACM SlpE OFWOOD PLATES, STAGGERING 12" O.C. ONOPPOSITE SIDE. 5/8" THICK GYPSUMWALLBOARD, PAPER OR VINYL PACED WITHBEVELER, SQUARE, TAPERED OR ROUNDEDEDGES. WALLBOARD NAILED TO EACH STUDl' O.C. W 6D CEMENT COATED NAILS, 1 7/8"LONG, .Ø915' SWANK DIAM. AND 1/4" DIAM.WEAD. AS AN ALTERNATE, No. 6 BUGLEHEAD DRYWALL SCREWS, 1 1/8" LONG, MAYBE SUBSTITUTED FOR THE 6D CEMENTBOATED NAILS. WHEN USED IN WIDTHSOTHER THAN 48," WALLBOARD TO BEINSTALLED HORIZONTALLY. WALLBOARDJOINTS COVERED WITH TAPE AND JOINTCOMPOUND. NAIL HEADS COVERED WITHJOINT COMPOUND. AS AN ALTERNATE, NOM.3/32' THICK GYPSUM VENEER PLASTER MAYBE APPLIED TO ENTIRE SURFACE OFCLASSIFIED VENEER BASEBOARD. JOINTSREINFORCED. (OPTIONAL) 3 1/2" MAXTWICKNESS GLASS OR MINERAL FIBER BATTINSULATION STAPLED TO STUDS.

1-HR FLOOR / CEILING ASSEMBLY 2-HR SHAFT WALL I-HR CORRIDOR WALLTYPICAL AT ALL APARTMENT FLOORS, UNLESS NOTED OTHERWISE l-1/2" = l'-Ø' SEE BUILDING PLANS FOR LOCATIONS 1-1/2" = 1'-Ø' TYPICAL AT WALLS BETWEEN DWELLING UNITS AND CORRIDORS 1-1/2' = 1'-Ø"

(1) LAYER 1/2" GYP. BD. * SUBSTITUTE 5/8" TYPE × GYPSUM BOARDEACH SIDE (*) AT CONTRACTOR'S OPTION(W.R. 1/2' TYPE ×WALLBOARD AT WET SIDE OFBATWROOM AND LAUNDRYWALLS)

2×4 STUDS (U.N.0) �04216' O.C.-SEE PLANS

><

DIMENSlONS TO WALL PACEARE TO FACE OF STUD

DIMENSIONS TO WALL C.L.ARE TO C.L. OF STUD

(1) LAYER 5/8" TYPE × GYP.BD. EACH SIDE(W.R. 5/8" TYPE × FIRERESISTlvE WALLBOARD ATWET SIDE OF BATHROOMAND LAUNDRY WALLS)

2×4 STUDS (U.N.0) e 16" O.C.-SEE PLANS

DIMENSIONS TO WALL PACEARE TO FACE OF STUD

GA FILE NO. WP 3514GENERIC

1 WOUR FIRE35 TO 39 STC SOUND

GYPSUM LUALLBOARD,WOOD STUDS

ONE LAYER 5/8" TYPE × GYPSUMWALLBOARD OR GYPSUM VENEER BASEAPPLIED PARALLEL OR AT RIGHT ANGLESTO EACM SipE OF 2×4 WOOD STUDS 16" O.C.WITH 1-1/4" TYPE W DRYWALL SCREWS AT 12'O.C.

JOINTS STAGGERED 16' ON OPPOSITE SIDES.(LOAD BEARING)

THICKNESS: 4-3/4"APPROX. WElGHT: 1 PSFFIRE TEST: SWRI Øl-4511-619, 8-19-92SOUND TEST: (G4W NG-246FT, 1-2-65)

DIMENSIONS TO WALL C.L.ARE To C.L. OF STUD

(1) LAYER 5/8' TYPE ×GYP. BD. EACH SIDE(W.R. 5/8" 'AQUA-TOUGW' FIRE RESISTIVEWALLBOARD AT WETSipE OF BATWROOMAND LAUNDRY WALLS)

- - 1" A IR SPACE

3-1/2" ACOUSTIC BATTINSULATION, TYPICALEACM SIDE

2×4 STUDS (U.N.0) �04216 "O.C. EACH SIDE- SEEPLANS

FIREBLOCK PER IBC117.2 AT 10'-Ø" WORIZ.MAX. WITH 1/2' GYP.BD. (ALT: GLASSFIBER BATTS PER IBC111.2.1.1)

DIMENSIONS IN PLANARE TO C.L. OF AIR SPACE

GA FILE NO. WP 337ØGENERIC

1 HOUR FIRE45 TO 49 STC SOUND (W/O INSUL.)

El TO ½½ ATF. AnllND (Ill/ INAlll )

GYPSUM WALLBOARD,WOOD STUDS

ONE LAYER 5/8" TYPE × GYPSUMWALLBOARD OR GYPSUM VENEER BASEAPPLIED PARALLEL OR AT RIGHT ANGLESTO EACM SIDE OF DOUBLE ROW OF 2×4WOOD STUDS 16' O.C. ON SEPARATE PLATESl' APART WITH 6p COATED NAILS, 1-7/8"LONG, Ø.0915' SWANK, 1/4' WEADS, 7" O.C.

JOINTS STAGGERED 16' ON OPPOSITE SIDES.WORIZONTAL BRACING REQUIRED ATMID - WEIGHT. (LOADBEARING)

THICKNESS: 9-1/2'APPRO×. WEIGHT: 8 PSFFIRE TEST: SEE WP 36Ø5

(UL R1319-4, 6, 6 -17-52UL R2111-39, 1-2Ø-66UL R3501-52, 3-15-66UL DESIGN U3Ø5ULC DESIGN W3Øl)

SOUND TEST: ESTIMATED(WITHOUT INSULATION)

NON-RATED INTERIOR NON-BEARING PARTITION 1-HR INTERIOR BEARING WALL I-HR DWELLING UNIT SEPARATION WALLTO BE USED AS APPLICABLE 1-1/2" = 1'-Ø' SEE BUILDING PLANS FOR LOCATIONS 1-1/2" = 1'-Ø' TYPICAL AT WALLS BETWEEN DWELLING UNITS 1-1/2' = 1'-Ø"

o

<

O cOU

EEDRAWING

RELEASE OG

03-21-14 - PDP Submittal12-01-14 - 65% Set01-09-15 - FDP Submittal01-14-15 - Permit Set03-20-15 - 98% Review Set04-03-15 - 98% CD's

REVISIONS

DATE

March 21, 2014

JOB No.

542813SHEET No.

A0.10