kajaaniKAPPAi™ and kajaaniBRITEi™for Fiber Line Optimization
kajaani
B54_09_0_EN.p65 6.2.2002, 16:471
© Metso Automation 2
Reliable Sampling &Sample HandlingYears and years of continuous operation have proven thereliability of the Kajaani sampling technologies. Metal-to-metal construction, robust design and no gaskets of thePiston/Cylinder ensure that the samplers can operate re-liably with a year’s minimum service period.
Sampler type is selected accord-ing to the application and processconditions in the sampling point,e.g. pressure and consistency.Manual spot samples can also beanalyzed. In addition, an optionallaboratory sample collector maybe included in the system. Thisdevice collects a representativesample for parallel lab analyses
from each sampler installation point. Sample collection ispart of pulp mills’ ISO 9000/14000 program.
The sampling devices are mounted to the process pipe-line. The device extracts pulp samples, dilutes them withwater, and delivers them to the analyzer’s washing unit.
Efficient and Repeatable SampleWashing Reveals Pulp QualityThe analyzer’s operating sequence begins with samplingfrom the process. The sample is transported to the wash-ing unit where the excess process and transport water aredrained off. The sample is then washed with warm andcold water, mixed thoroughlywith pressurized air, and itsinitial consistency is mea-sured at a constant volume.After this the sample process-ing method is dependent onthe selected measurements.Measuring sequences can beconfigured separately foreach sampling point.
When the measuring sequence is over, the analyzer iswashed and calibrated automatically by means of watermeasurement.
If the analyzer has one washing unit, the operating se-quence is repeated as such for each sample. With twowashing units, their sequences overlap partially so that anew result is available every 31/
2 minutes.
Proven Reliability, Speed and Accuracy
True Modularity for Widest Applicability
EOP Kappa#
Final Brightnesskajaani KAPPAi and BRITEi analyzersapplicable to the entire fiber line.
Gives You FlexibilityThe experience we have gained from over a hun-dred analyzer installations together with the newfeatures and design of kajaaniKAPPAi andkajaaniBRITEi analyzers, assure the efficient controlto cover the whole fiber line. Our digester applica-tions with kajaaniKAPPAi meet most of Kappa mea-surement needs, such as high yield, continuous mid-point, batch and continuous blow pulp. On-lineKappa measurements at Oxygen delignification,from front of the bleaching till EOP Kappa are todaymill standards. The absolute brightness measure-ment is becoming more and more common inmodern mills. Our new solution to applykajaaniBRITEi to absolute brightness control and fi-nal pulp quality control finalizes the bleaching con-trol success.
All the analyzers’ technological features have been inte-grated in a way that expandability is possible without ma-jor equipment changes but more or less with plug andplay field retrofit additions. Sampling devices, sample treat-ment units and new measurements can be added to the
system later on. This assures that our customer will ben-efit from all the latest development changes in his fiberline, with the same platform of the analyzer.
KajaaniKAPPAi and kajaaniBRITEi are modular twins with
compatible components and features; they demonstrate
true modularity for the widest applicability.
= open= closed
Discharge
B54_09_0_EN.p65 6.2.2002, 16:472
© Metso Automation 3
Unsurpassed Accuracy withthe Sweep MeasurementThe latest invention to meet the currentcontrol needs of Kappa and Brightnessmeasurement is our unique Sweep Mea-surement (pat. pend.) which measures theoptical response of the measured sub-stance over a range of consistency swing.Together with the pressurized measure-ment technology, the sweep method cre-ates high accuracy of Kappa and Brightnessand is substantially faster than our previoustechnology. Thanks to this unique method, analyzer giveslinear response to Kappa and Brightness. The traditional
The unique Sweeptechnology measure-ment based on thecontinuous optical re-sponse curve.
linear two point calibration can be applied, which makessystem commissioning easier and faster.
Kappa number is measured optically. While a sampleflows through a measuring cell, Xenon light is directedthrough it and the light scattering is measured at differ-ent wavelengths.
Pulp brightness is measured in an optical cell where thelight reflectance and scattering properties of pulp fibersare measured by means of Xenon light. The analyzer alsomeasures the flocculation index of the pulp for hardwood/softwood detection.
An additional benefit of the new measurement tech-nology is the simpler measurement sequence which re-duces the load on the sample treatment system. The sys-tem maintenance need has also been reduced apprecia-bly due to fewer sequence cycles.
Operating sequence of kajaaniBRITEi and kajaaniKAPPAi analyzers
Pressurized measurement totally eliminates the air bubbleeffect which causes light scattering and thus inaccuratemeasurement in a non-pressurized measurement cell.
31/2 min/resultSample 1
washingSample 2washing
Samplecollecting /
Analyzerwashing
Kappa,Brightness
measurements,HW/SW detection
Sample 1transport
Sampling 1
Washingunit 1
Washingunit 2
Measurementunit
Bright-nessCsKappa
Sampling 2Sample 2transport
Not pressurized Pressurized
Xen
on
lig
ht
Xen
on
lig
ht
0
0,2
0,4
0,6
0,8
1,0
1,2
StartStop
Det
. sig
nal
Consistency
B54_09_0_EN.p65 6.2.2002, 16:473
© Metso Automation 4
Advanced Self-DiagnosticsThe analyzer’s self-diagnostics constantly monitors and
tunes the system operation and analyzes the accept-
ability of the obtained results.
At preprogrammed intervals the analyzer performs a
self-test, checking the operation of valves, flow rates,
and level sensors. If an error is detected, the system
alerts the operators and gives a report that specifies the
necessary service action and the order code of any spare
parts that may be required.
kajaaniSAM Tool
Guiding Interface –Smart and Simple Tool to Operate
The analyzer canalso be connected tothe mill’s DCS withMODBUS serial bus.
Screen shots of the new kajaaniSAM Tool.
icon gives instructions what to do if something unex-
pected happens.
Measurement results can be displayed in either nu-
merical or graphic format. Trend variables are user se-
lectable, and older result files can be viewed from the
history files.
CommunicatorCommunicator is the local, robust terminal for daily and
smaller operations such as lab sample collection.
Remote OperationA standard modem gives the
opportunity to remote-
run the kajaaniSAM
Tool and to contact
the Help desk at
Metso Automa-
tion’s service
center.
kajaaniSAM Tool is a
guiding interface for
operation. This Win-
dows-based software
has been designed to
visualize the kajaani-
KAPPAi and kajaani-
BRITEi analyzers’ op-
erations, including
configuration, diag-
nostics, preventive
maintenance, and
trouble-shooting.
The software is used
to display and edit in-
formation of analyzer
status. Valve testing
can be carried out by
clicking directly on the
graphics. Information
B54_09_0_EN.p65 6.2.2002, 16:474
© Metso Automation 5
day time CV Anal. Lab. difference
14.8.1999 6,36 1,5094 17,9 18,0 -0,1
17.8.1999 7,32 1,4394 19,1 18,7 0,4
11,25 1,4189 19,4 19,2 0,2
20.8.1999 7,36 1,5119 29,3 29,7 -0,4
28.8.1999 9,00 1,3361 17,0 16,7 0,3
11,22 1,4380 21,0 19,7 1,3
2.9.1999 11,55 1,4623 16,6 15,9 0,7
12,37 1,4579 16,8 16,2 0,6
3.9.1999 9,09 1,4798 16,1 15,2 0,9
4.9.1999 6,36 1,5245 17,8 17,7 0,1
8,03 1,4590 17,8 17,8 0,0
7.9.1999 12,22 1,4415 14,8 15,0 -0,2
14,28 1,4656 17,0 17,8 -0,8
8.9.1999 12,03 1,4570 17,2 16,5 0,7
12,55 1,4400 17,5 16,8 0,7
9.9.1999 12,52 1,4458 20,8 20,7 0,1
13,35 1,4720 23,9 23,3 0,6
10.9.1999 11,12 1,4704 17,5 17,5 0,0
11,43 1,4465 18,0 18,3 -0,3
18.9.1999 6,40 1,4067 17,6 18,3 -0,7
7,22 1,4277 17,7 18,5 -0,8
25.9.1999 8,04 1,3444 16,3 16,6 -0,3
9,08 1,3784 15,7 16,3 -0,6
12,17 1,4084 19,7 20,4 -0,7
2.10.1999 5,37 1,3975 17,9 17,5 0,4
7,01 1,3656 19,1 19,0 0,1
7.10.1999 12,19 1,3903 17,7 19,0 -1,3
Long-term PerformanceAssuredCalibration StandardThe kajaaniKAPPAi and kajaaniBRITEi analyzers have a
simple, two-step guiding procedure which allows the op-
erators to check the measurement accuracy and calibra-
tion at any time. In addition, this procedure can be used
after service operations to return the system to the origi-
nal calibration if needed.
There’s no need to sweat over maintenance – self-diagnostics runs in the background watching over every action. Regularchecking and routine preventive maintenance ensure high reliability. When needed, Metso Automation’s service is alwayswithin reach by phone or modem to provide in-depth support.
0
5
10
15
20
25
30
35
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29
Anal.Lab.
EVERYMONTH
EVERY6 MONTHS
EVERYYEAR
TIME MAINTENANCE SERVICEFOLLOW UP
CONTINUOUSSELFDIAGNOSTICS
• General cleaningand operation tests
• Water and air filterscleaning
• Pressure switchtest
• Sampling devicecheck
• Analyze follow-upresult and runcalibration standardif needed to meet customer’s quality system requirements
• Guiding interface• Help pages• Service instructions• Guiding spare part orders
• Standard modemconnection to MetsoAutomationservice center
• Pressures OK?• General operation?• Leakage?• Add washing
chemical• Check error page
• Automatic tests of optics, electronics and pressureson the background, error report
• Corrective automatic tests weekly with report, newparameters, chemical wash
• Trained service experts
B54_09_0_EN.p65 6.2.2002, 16:475
© Metso Automation 6
SD-501 SD-502 SD-505 SD-506 Midpointsampler
Piston-type
AISI 316L
6 –15 %
max. 2500 kPa(25 bar, 363 psi)
Neck flange:
DN100, PN40,DIN2635, AISI316L
Instr. air connections
IP 55 (NEMA 4X)
Flow-type
AISI 316L
0.5 –15 %
200-2500 kPa(2-25 bar, 29-363 psi)
Included in delivery
15 kg (33 lbs)
IP 55 (NEMA 4X)
Type
Application
Material
Consistency range
Ambient temperature
Humidity
Process temperature
Operating pressure
Process coupling
Weight
Protection class
Transport water
Sample lines
Flow-type
Titan Grade 2
0.5 –15 % 0.5 –15 %
AISI 316
100 m (328 ft)Max.length recomm.*)
• For screened pulps• Approved pressurevessel
Remote sampler
Samplers
Model
Lab samplecollectors
Vessel
AISI 316
0.5 –15 %
max. 55°C (131°F)
max. 180°C (356°F)
max. 2500 kPa(25 bar, 363 psi)
78 kg (172 lbs)
IP 55
100 m (328 ft)
Included in delivery
5-50°C (41-122°F)
10-100 %
max. 160°C (320°F)
100 m (328 ft)
200-2500 kPa(2-25 bar, 29-363 psi)
12 kg (26.4 lbs)
IP 55 (NEMA 4X)
max. 1000 kPa(10 bar, 145 psi)
20 kg (43.9 lbs)
IP 55
50 m (164 ft)
• Unscreened pulps: AISI, DN20, or spiral-reinforced PVC-hose, int. diam. 25 mm (23/24”) e.g.Heliflex; Minimum bending radius 250 mm (9 7/8”)
• Screened pulps: AISI, DN15, or spiral-reinforced PVC-hose, int. diam. 19 mm e.g. Heliflex
100 m (328 ft)
• Pressure: 400-600 kPa (4-6 bar, 58-87 psi) • Recommended tube: DN10 • Coupling: ISO 7/1-Rp 1/4 int. thread
• Kappa sampling needs mill water (temperature for blow line, midpoint 40°…60°C (104…140°F))• Brightness sampling needs deionized water. See specs in analyzer section.
• Pressure: 400-800 kPa (4-8 bar, 58-116 psi), allowed variation max. ± 25 kPa (0.25 bar, 3.6 psi)• Max. consumption: 19 mm sample line: 40 l (10.6 US gal)/min, Recommended tube: DN15• 25 mm sample line 50 l (13.2 US gal)/min, Recommended tube: DN20• Coupling ISO 7/1-Rp 1/2 int. thread
55 kg (121 lbs)
Kappa labsample collector
Sample vessels max 5 pcs / washing unit
Materials • Valves: AISI • Collector body: AISI 316
Ambient temperature 5…50°C (41…122°F)
Humidity 10…100%
Sample line/
Disharge connections
for 50 mm (2”) hose (included in delivery)
Dimensions (h x w x d) 450 x 1040 x 400 mm(17 23/32” x 40 15/16” x 15 3/4”)
Model Bright labsample collector
• For unscreened pulpsand low consistencies(Cs < 6%)
• For process pipes withdiam. < 200 mm (8”)
• For unscreened pulpscontaining chlorinecompounds.
• For process pipes withdiam.< 200 mm (8”)
• For the analysis ofmanual samples
• Wall installation
• Vessel for midpointsampling
• Contains 4 valvesand SD-502
*) If alterations, please contact your closest service.
Control of pneumatic actuators from analyzer.
B54_09_0_EN.p65 6.2.2002, 16:486
© Metso Automation 7
SpecificationsKappa#Meas.range < 2 2–8 8–20 20–40 40–60 > 60(Kappa unit)Accuracy (σ) 0.3+σL 0.3+σL 0.7+σL 1.0+σL 1.5+σL 2.0+σL
Repeatab. (σ) 0.1 0.1 0.25 0.5 1.0 1.2Stability 1 1 1 1 1 1(% of max. reading of each meas. range/month)
BrightnessMeas.range (%) 40–60 60–85 85–90+Accuracy (σ) 1.0+σL 0.8+σL 0.4+σL
Repeatability(σ) 0.40 0.35 0.30
σL=standard deviation of laboratory
HW/SW -ratio/ Fiber length measurementBased on flocculation analysis(internally: CV-value, correlates with weight-weighted fiber length)Measurement range ................. 0.4–4.0 mmHW/SW-ratio ............................ 0…100 %Accuracy .................................. ±15 %
Measurement UnitAmbient temperature ............... 5-50°C (41-122°F)Dimensions .............................. 165 x 87 x 72 cm(height x width x depth) ............ (65 “ x 34 “ x 28 1/2 ”)Weight ...................................... 130 kg (286,3 lbs)Protection Class• Analyzer Cabinet .................... IP 54 (NEMA 3S)• Electronics Unit ...................... IP 65 (NEMA 9)• Connection Box ...................... IP 65 (NEMA 9)Operating Voltage .................... 90…132/175…264 VAC,
44…440 Hz, 350 VA / Wash. UnitOperating Voltage; pump unit .. 3~ 400VAC OR 3~208 VACAnalog Outputs ........................ max. 24 pcs, 0-20 mA/ 4-20 mA,
isolated (max. load 800Ω)(furnished 8,16 or 24 pcs)
Binary Outputs ......................... max. 11 pcs,opening/closing contact,(24-48V/1 A)max. 20 x 24 VDC control
Binary Inputs ............................ max. 20 pcs, opto isolated24-48 VDC
Serial Interface ......................... RS-232/RS-485 and/or MODBUS(contact Kajaani for closer info)
Pump 400 VAC/50HzOperating voltage ..................... 400 VAC 3-phase YFrequency ................................ 50 HzRated Output ............................ 0,18 kWPump Delivery .......................... 20 dm3 /minDelivery Head Lift ..................... 6.0 – 6.5 mwcProtection Class ....................... IP55Pump 208 VAC/60HzOperating voltage ..................... 208 VAC 3-phase YFrequency ................................ 60 HzRated Output ............................ 0,21 kWPump Delivery .......................... 20 dm3 /minDelivery Head Lift ..................... 6.0 – 6.5 mwcProtection Class ....................... IP553-phase Transformer (option)Type ......................................... 3MI tnr-22688Power ....................................... 350 VAInput Voltages .......................... 380-440-460-480-575 VACOutput Voltage ......................... 208 VACFrequency ................................ 50-60HzVector Group ............................ Yan0 (economizing circuit)Protection Class ....................... IP44Thermal Protection Class ......... B (IEC 85)
(amb. temp. max. 80°C (176 °F))If the available feed voltage differ from those specified above,a special transformer and pump motor are needed.
Washing Unit(max. 2 /Measurement Unit)Sample Lines ........................... 1-5 lines/washing unit• Diameter ................................ 19 or 25 mm ( 3/4”- 63/64”)• Manual sample funnelAmbient Temperature ............... 5-50°C (41-122°F)Dimensions .............................. 165 x 67 x 72 cm(h x w x d) ................................ (65 “ x 26 1/2 “ x 28 1/2 “)Weight ...................................... 190 kg (418,5 lbs)Protection Class ....................... IP 54 (NEMA 3S)
Recommendations for water:
Measurement Warm Cold Deionizedwater water water
Brightness D0, D1, D2 xBr.+ Kappa# D0, D1, D2 xKappa# x x
• If pulp contains alkali before the DO-stage or if there is no O2-stage, warm water is needed.
• Coupling ................................. ISO 7/1 - Rp 1/2• Recommended pipe ............... DN20Cold Water .............................. Chemically purified water• Pressure 500-800 kPa (5-8 bar,
73-116 psi)• Intake; 1 unit ........................... av. 4 l (1 US gal)/minmomentary peak value 17 l (4.5 US gal)/min
• Intake; 2 units ........................ av. 6 l (1.6 US gal)/minmomentary peak value 24 l (6.3 US gal)/min
• Filter ....................................... 100 µmWarm Water ............................ Mill water• Heater recommended to stabilize temperature.• Temperature ........................... 50-60°C (122-140°F)• Allowed variation during sequence ± 2.5°C (± 4.5°F)• Pressure ................................. 300-600 kPa (3-6 bar, 44-87 psi)• Intake; 1 unit ........................... av. 60-105 l/h (16-28 US gal/h)momentary peak value 282 l (74.5 US gal)/h
• Intake; 2 units ......................... av. 105-180 l/h (28-48 USgal/h)momentary peak value 282 l (74.5 US gal) /h
• Filter ....................................... 100 µmDeionized Water ..................... Boiler water specification• Conductivity ............................ < 0,3 mS/m• pH........................................... 6 - 8• KMnO4 consumption .............. < 4 mg/l• SiO2 ........................................ < 0.02 mg/l• Temperature ........................... 18-50°C (64-122°F)• Allowed variation during sequence ± 5°C (± 9°F)• Pressure ................................. 500-800 kPa
(5-8 bar, 72.5-116 psi))• Intake; 1 unit ........................... av. 4 l (1 US gal)/minmomentary peak value 17 l (4.5 US gal)/min
• Intake; 2 units ......................... av. 6 l (1.6 US gal)/minmomentary peak value 24 l (6.3 US gal)/min
Instrument Air• Pressure ................................. 400-600 kPa (4-6 bar, 58-87 psi)• Coupling ................................. ISO 7/1 - Rp 1/2• Recommended pipe ............... DN15Discharge Tube ........................ Diameter 50 mm (1 31/32 “)Cooling System for Electronics• Coupling ................................. ISO 7/1 - Rp 1/2, 2 pcs• Water pressure ....................... max.1600 kPa (16 bar, 232psi)• Water temperature ................. 0-30°C (32-86°F)• See manual for further information.ClO2 Neutralization• Coupling ................................. ISO 7/1 - Rp 1/2• Pressure ................................. 100-800 kPa (1-8 bar,14-116 psi)
Ext.diam. Int.diam. Wall
DN15 21.3 mm [27/32“] 18.1 mm [23 /32“] 1.6 mm [1/16“]DN20 26.9 mm [1 1/16“] 23.7 mm [15/16“] 1.6 mm [1/16“]
B54_09_0_EN.p65 6.2.2002, 16:487
Metso Automation
Field Systems Division
Kehräämöntie 3 , P.O. Box 177
FIN-87101 Kajaani
Finland
Tel. +358 20 483 120
Fax +358 20 483 121
Europe
Levytie 6 , P.O. Box 310
FIN-00811 Helsinki
Finland
Tel. +358 20 483 150
Fax +358 20 483 151
North America
3100 Medlock Bridge Road, Suite 250
Norcross, GA 30071
USA
Tel. +1 770 446 7818
Fax +1 770 242 8386
Latin America
Av. Central 181, Chácaras Reunidas
12238-430 São José dos Campos
SP Brazil
Tel. +55 12 3935 3500
Fax +55 12 3935 3535
Asia Pacific
501 Orchard Road
#05-09 Wheelock Place
238880 Singapore
Tel. +65 735 5200
Fax +65 735 2955
www.metsoautomation.com
B54
09.
0_E©
Met
so A
uto
mat
ion
, 1/2
002
The key to the success
of effective fiber line operation and
total product quality is more than ever depending
on continuous information provided by on-line
analyzers and measurements. Our 30-year-long
history in creating innovative new ways to
measure and control processes has proven to be
an ongoing success. Today 80 % of the world’s
fiber lines are benefiting from our solutions for
bleaching process control. Still today, the Kajaani
sensors and analyzers are the cornerstones of
control solutions that assure cost effective
pulp production with the least
environmental impact.