kajaaniKAPPAi™ and kajaaniBRITEi™for Fiber Line Optimization

kajaani

B54_09_0_EN.p65 6.2.2002, 16:471

Page 2: kajaaniKAPPAi and kajaaniBRITEi for Fiber Line Optimizationinkom-trade.com/files/kajaani_1.pdf · for Fiber Line Optimization kajaani B54_09_0_EN.p65 1 6.2.2002, ... Manual spot samples

© Metso Automation 2

Reliable Sampling &Sample HandlingYears and years of continuous operation have proven thereliability of the Kajaani sampling technologies. Metal-to-metal construction, robust design and no gaskets of thePiston/Cylinder ensure that the samplers can operate re-liably with a year’s minimum service period.

Sampler type is selected accord-ing to the application and processconditions in the sampling point,e.g. pressure and consistency.Manual spot samples can also beanalyzed. In addition, an optionallaboratory sample collector maybe included in the system. Thisdevice collects a representativesample for parallel lab analyses

from each sampler installation point. Sample collection ispart of pulp mills’ ISO 9000/14000 program.

The sampling devices are mounted to the process pipe-line. The device extracts pulp samples, dilutes them withwater, and delivers them to the analyzer’s washing unit.

Efficient and Repeatable SampleWashing Reveals Pulp QualityThe analyzer’s operating sequence begins with samplingfrom the process. The sample is transported to the wash-ing unit where the excess process and transport water aredrained off. The sample is then washed with warm andcold water, mixed thoroughlywith pressurized air, and itsinitial consistency is mea-sured at a constant volume.After this the sample process-ing method is dependent onthe selected measurements.Measuring sequences can beconfigured separately foreach sampling point.

When the measuring sequence is over, the analyzer iswashed and calibrated automatically by means of watermeasurement.

If the analyzer has one washing unit, the operating se-quence is repeated as such for each sample. With twowashing units, their sequences overlap partially so that anew result is available every 31/

2 minutes.

Proven Reliability, Speed and Accuracy

True Modularity for Widest Applicability

EOP Kappa#

Final Brightnesskajaani KAPPAi and BRITEi analyzersapplicable to the entire fiber line.

Gives You FlexibilityThe experience we have gained from over a hun-dred analyzer installations together with the newfeatures and design of kajaaniKAPPAi andkajaaniBRITEi analyzers, assure the efficient controlto cover the whole fiber line. Our digester applica-tions with kajaaniKAPPAi meet most of Kappa mea-surement needs, such as high yield, continuous mid-point, batch and continuous blow pulp. On-lineKappa measurements at Oxygen delignification,from front of the bleaching till EOP Kappa are todaymill standards. The absolute brightness measure-ment is becoming more and more common inmodern mills. Our new solution to applykajaaniBRITEi to absolute brightness control and fi-nal pulp quality control finalizes the bleaching con-trol success.

All the analyzers’ technological features have been inte-grated in a way that expandability is possible without ma-jor equipment changes but more or less with plug andplay field retrofit additions. Sampling devices, sample treat-ment units and new measurements can be added to the

system later on. This assures that our customer will ben-efit from all the latest development changes in his fiberline, with the same platform of the analyzer.

KajaaniKAPPAi and kajaaniBRITEi are modular twins with

compatible components and features; they demonstrate

true modularity for the widest applicability.

= open= closed

Discharge

B54_09_0_EN.p65 6.2.2002, 16:472

Page 3: kajaaniKAPPAi and kajaaniBRITEi for Fiber Line Optimizationinkom-trade.com/files/kajaani_1.pdf · for Fiber Line Optimization kajaani B54_09_0_EN.p65 1 6.2.2002, ... Manual spot samples

© Metso Automation 3

Unsurpassed Accuracy withthe Sweep MeasurementThe latest invention to meet the currentcontrol needs of Kappa and Brightnessmeasurement is our unique Sweep Mea-surement (pat. pend.) which measures theoptical response of the measured sub-stance over a range of consistency swing.Together with the pressurized measure-ment technology, the sweep method cre-ates high accuracy of Kappa and Brightnessand is substantially faster than our previoustechnology. Thanks to this unique method, analyzer giveslinear response to Kappa and Brightness. The traditional

The unique Sweeptechnology measure-ment based on thecontinuous optical re-sponse curve.

linear two point calibration can be applied, which makessystem commissioning easier and faster.

Kappa number is measured optically. While a sampleflows through a measuring cell, Xenon light is directedthrough it and the light scattering is measured at differ-ent wavelengths.

Pulp brightness is measured in an optical cell where thelight reflectance and scattering properties of pulp fibersare measured by means of Xenon light. The analyzer alsomeasures the flocculation index of the pulp for hardwood/softwood detection.

An additional benefit of the new measurement tech-nology is the simpler measurement sequence which re-duces the load on the sample treatment system. The sys-tem maintenance need has also been reduced apprecia-bly due to fewer sequence cycles.

Operating sequence of kajaaniBRITEi and kajaaniKAPPAi analyzers

Pressurized measurement totally eliminates the air bubbleeffect which causes light scattering and thus inaccuratemeasurement in a non-pressurized measurement cell.

31/2 min/resultSample 1

washingSample 2washing

Samplecollecting /

Analyzerwashing

Kappa,Brightness

measurements,HW/SW detection

Sample 1transport

Sampling 1

Washingunit 1

Washingunit 2

Measurementunit

Bright-nessCsKappa

Sampling 2Sample 2transport

Not pressurized Pressurized

Xen

on

lig

ht

Xen

on

lig

ht

0

0,2

0,4

0,6

0,8

1,0

1,2

StartStop

Det

. sig

nal

Consistency

B54_09_0_EN.p65 6.2.2002, 16:473

Page 4: kajaaniKAPPAi and kajaaniBRITEi for Fiber Line Optimizationinkom-trade.com/files/kajaani_1.pdf · for Fiber Line Optimization kajaani B54_09_0_EN.p65 1 6.2.2002, ... Manual spot samples

© Metso Automation 4

Advanced Self-DiagnosticsThe analyzer’s self-diagnostics constantly monitors and

tunes the system operation and analyzes the accept-

ability of the obtained results.

At preprogrammed intervals the analyzer performs a

self-test, checking the operation of valves, flow rates,

and level sensors. If an error is detected, the system

alerts the operators and gives a report that specifies the

necessary service action and the order code of any spare

parts that may be required.

kajaaniSAM Tool

Guiding Interface –Smart and Simple Tool to Operate

The analyzer canalso be connected tothe mill’s DCS withMODBUS serial bus.

Screen shots of the new kajaaniSAM Tool.

icon gives instructions what to do if something unex-

pected happens.

Measurement results can be displayed in either nu-

merical or graphic format. Trend variables are user se-

lectable, and older result files can be viewed from the

history files.

CommunicatorCommunicator is the local, robust terminal for daily and

smaller operations such as lab sample collection.

Remote OperationA standard modem gives the

opportunity to remote-

run the kajaaniSAM

Tool and to contact

the Help desk at

Metso Automa-

tion’s service

center.

kajaaniSAM Tool is a

guiding interface for

operation. This Win-

dows-based software

has been designed to

visualize the kajaani-

KAPPAi and kajaani-

BRITEi analyzers’ op-

erations, including

configuration, diag-

nostics, preventive

maintenance, and

trouble-shooting.

The software is used

to display and edit in-

formation of analyzer

status. Valve testing

can be carried out by

clicking directly on the

graphics. Information

B54_09_0_EN.p65 6.2.2002, 16:474

Page 5: kajaaniKAPPAi and kajaaniBRITEi for Fiber Line Optimizationinkom-trade.com/files/kajaani_1.pdf · for Fiber Line Optimization kajaani B54_09_0_EN.p65 1 6.2.2002, ... Manual spot samples

© Metso Automation 5

day time CV Anal. Lab. difference

14.8.1999 6,36 1,5094 17,9 18,0 -0,1

17.8.1999 7,32 1,4394 19,1 18,7 0,4

11,25 1,4189 19,4 19,2 0,2

20.8.1999 7,36 1,5119 29,3 29,7 -0,4

28.8.1999 9,00 1,3361 17,0 16,7 0,3

11,22 1,4380 21,0 19,7 1,3

2.9.1999 11,55 1,4623 16,6 15,9 0,7

12,37 1,4579 16,8 16,2 0,6

3.9.1999 9,09 1,4798 16,1 15,2 0,9

4.9.1999 6,36 1,5245 17,8 17,7 0,1

8,03 1,4590 17,8 17,8 0,0

7.9.1999 12,22 1,4415 14,8 15,0 -0,2

14,28 1,4656 17,0 17,8 -0,8

8.9.1999 12,03 1,4570 17,2 16,5 0,7

12,55 1,4400 17,5 16,8 0,7

9.9.1999 12,52 1,4458 20,8 20,7 0,1

13,35 1,4720 23,9 23,3 0,6

10.9.1999 11,12 1,4704 17,5 17,5 0,0

11,43 1,4465 18,0 18,3 -0,3

18.9.1999 6,40 1,4067 17,6 18,3 -0,7

7,22 1,4277 17,7 18,5 -0,8

25.9.1999 8,04 1,3444 16,3 16,6 -0,3

9,08 1,3784 15,7 16,3 -0,6

12,17 1,4084 19,7 20,4 -0,7

2.10.1999 5,37 1,3975 17,9 17,5 0,4

7,01 1,3656 19,1 19,0 0,1

7.10.1999 12,19 1,3903 17,7 19,0 -1,3

Long-term PerformanceAssuredCalibration StandardThe kajaaniKAPPAi and kajaaniBRITEi analyzers have a

simple, two-step guiding procedure which allows the op-

erators to check the measurement accuracy and calibra-

tion at any time. In addition, this procedure can be used

after service operations to return the system to the origi-

nal calibration if needed.

There’s no need to sweat over maintenance – self-diagnostics runs in the background watching over every action. Regularchecking and routine preventive maintenance ensure high reliability. When needed, Metso Automation’s service is alwayswithin reach by phone or modem to provide in-depth support.

0

5

10

15

20

25

30

35

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29

Anal.Lab.

EVERYMONTH

EVERY6 MONTHS

EVERYYEAR

TIME MAINTENANCE SERVICEFOLLOW UP

CONTINUOUSSELFDIAGNOSTICS

• General cleaningand operation tests

• Water and air filterscleaning

• Pressure switchtest

• Sampling devicecheck

• Analyze follow-upresult and runcalibration standardif needed to meet customer’s quality system requirements

• Guiding interface• Help pages• Service instructions• Guiding spare part orders

• Standard modemconnection to MetsoAutomationservice center

• Pressures OK?• General operation?• Leakage?• Add washing

chemical• Check error page

• Automatic tests of optics, electronics and pressureson the background, error report

• Corrective automatic tests weekly with report, newparameters, chemical wash

• Trained service experts

B54_09_0_EN.p65 6.2.2002, 16:475

Page 6: kajaaniKAPPAi and kajaaniBRITEi for Fiber Line Optimizationinkom-trade.com/files/kajaani_1.pdf · for Fiber Line Optimization kajaani B54_09_0_EN.p65 1 6.2.2002, ... Manual spot samples

© Metso Automation 6

SD-501 SD-502 SD-505 SD-506 Midpointsampler

Piston-type

AISI 316L

6 –15 %

max. 2500 kPa(25 bar, 363 psi)

Neck flange:

DN100, PN40,DIN2635, AISI316L

Instr. air connections

IP 55 (NEMA 4X)

Flow-type

AISI 316L

0.5 –15 %

200-2500 kPa(2-25 bar, 29-363 psi)

Included in delivery

15 kg (33 lbs)

IP 55 (NEMA 4X)

Type

Application

Material

Consistency range

Ambient temperature

Humidity

Process temperature

Operating pressure

Process coupling

Weight

Protection class

Transport water

Sample lines

Flow-type

Titan Grade 2

0.5 –15 % 0.5 –15 %

AISI 316

100 m (328 ft)Max.length recomm.*)

• For screened pulps• Approved pressurevessel

Remote sampler

Samplers

Model

Lab samplecollectors

Vessel

AISI 316

0.5 –15 %

max. 55°C (131°F)

max. 180°C (356°F)

max. 2500 kPa(25 bar, 363 psi)

78 kg (172 lbs)

IP 55

100 m (328 ft)

Included in delivery

5-50°C (41-122°F)

10-100 %

max. 160°C (320°F)

100 m (328 ft)

200-2500 kPa(2-25 bar, 29-363 psi)

12 kg (26.4 lbs)

IP 55 (NEMA 4X)

max. 1000 kPa(10 bar, 145 psi)

20 kg (43.9 lbs)

IP 55

50 m (164 ft)

• Unscreened pulps: AISI, DN20, or spiral-reinforced PVC-hose, int. diam. 25 mm (23/24”) e.g.Heliflex; Minimum bending radius 250 mm (9 7/8”)

• Screened pulps: AISI, DN15, or spiral-reinforced PVC-hose, int. diam. 19 mm e.g. Heliflex

100 m (328 ft)

• Pressure: 400-600 kPa (4-6 bar, 58-87 psi) • Recommended tube: DN10 • Coupling: ISO 7/1-Rp 1/4 int. thread

• Kappa sampling needs mill water (temperature for blow line, midpoint 40°…60°C (104…140°F))• Brightness sampling needs deionized water. See specs in analyzer section.

• Pressure: 400-800 kPa (4-8 bar, 58-116 psi), allowed variation max. ± 25 kPa (0.25 bar, 3.6 psi)• Max. consumption: 19 mm sample line: 40 l (10.6 US gal)/min, Recommended tube: DN15• 25 mm sample line 50 l (13.2 US gal)/min, Recommended tube: DN20• Coupling ISO 7/1-Rp 1/2 int. thread

55 kg (121 lbs)

Kappa labsample collector

Sample vessels max 5 pcs / washing unit

Materials • Valves: AISI • Collector body: AISI 316

Ambient temperature 5…50°C (41…122°F)

Humidity 10…100%

Sample line/

Disharge connections

for 50 mm (2”) hose (included in delivery)

Dimensions (h x w x d) 450 x 1040 x 400 mm(17 23/32” x 40 15/16” x 15 3/4”)

Model Bright labsample collector

• For unscreened pulpsand low consistencies(Cs < 6%)

• For process pipes withdiam. < 200 mm (8”)

• For unscreened pulpscontaining chlorinecompounds.

• For process pipes withdiam.< 200 mm (8”)

• For the analysis ofmanual samples

• Wall installation

• Vessel for midpointsampling

• Contains 4 valvesand SD-502

*) If alterations, please contact your closest service.

Control of pneumatic actuators from analyzer.

B54_09_0_EN.p65 6.2.2002, 16:486

Page 7: kajaaniKAPPAi and kajaaniBRITEi for Fiber Line Optimizationinkom-trade.com/files/kajaani_1.pdf · for Fiber Line Optimization kajaani B54_09_0_EN.p65 1 6.2.2002, ... Manual spot samples

© Metso Automation 7

SpecificationsKappa#Meas.range < 2 2–8 8–20 20–40 40–60 > 60(Kappa unit)Accuracy (σ) 0.3+σL 0.3+σL 0.7+σL 1.0+σL 1.5+σL 2.0+σL

Repeatab. (σ) 0.1 0.1 0.25 0.5 1.0 1.2Stability 1 1 1 1 1 1(% of max. reading of each meas. range/month)

BrightnessMeas.range (%) 40–60 60–85 85–90+Accuracy (σ) 1.0+σL 0.8+σL 0.4+σL

Repeatability(σ) 0.40 0.35 0.30

σL=standard deviation of laboratory

HW/SW -ratio/ Fiber length measurementBased on flocculation analysis(internally: CV-value, correlates with weight-weighted fiber length)Measurement range ................. 0.4–4.0 mmHW/SW-ratio ............................ 0…100 %Accuracy .................................. ±15 %

Measurement UnitAmbient temperature ............... 5-50°C (41-122°F)Dimensions .............................. 165 x 87 x 72 cm(height x width x depth) ............ (65 “ x 34 “ x 28 1/2 ”)Weight ...................................... 130 kg (286,3 lbs)Protection Class• Analyzer Cabinet .................... IP 54 (NEMA 3S)• Electronics Unit ...................... IP 65 (NEMA 9)• Connection Box ...................... IP 65 (NEMA 9)Operating Voltage .................... 90…132/175…264 VAC,

44…440 Hz, 350 VA / Wash. UnitOperating Voltage; pump unit .. 3~ 400VAC OR 3~208 VACAnalog Outputs ........................ max. 24 pcs, 0-20 mA/ 4-20 mA,

isolated (max. load 800Ω)(furnished 8,16 or 24 pcs)

Binary Outputs ......................... max. 11 pcs,opening/closing contact,(24-48V/1 A)max. 20 x 24 VDC control

Binary Inputs ............................ max. 20 pcs, opto isolated24-48 VDC

Serial Interface ......................... RS-232/RS-485 and/or MODBUS(contact Kajaani for closer info)

Pump 400 VAC/50HzOperating voltage ..................... 400 VAC 3-phase YFrequency ................................ 50 HzRated Output ............................ 0,18 kWPump Delivery .......................... 20 dm3 /minDelivery Head Lift ..................... 6.0 – 6.5 mwcProtection Class ....................... IP55Pump 208 VAC/60HzOperating voltage ..................... 208 VAC 3-phase YFrequency ................................ 60 HzRated Output ............................ 0,21 kWPump Delivery .......................... 20 dm3 /minDelivery Head Lift ..................... 6.0 – 6.5 mwcProtection Class ....................... IP553-phase Transformer (option)Type ......................................... 3MI tnr-22688Power ....................................... 350 VAInput Voltages .......................... 380-440-460-480-575 VACOutput Voltage ......................... 208 VACFrequency ................................ 50-60HzVector Group ............................ Yan0 (economizing circuit)Protection Class ....................... IP44Thermal Protection Class ......... B (IEC 85)

(amb. temp. max. 80°C (176 °F))If the available feed voltage differ from those specified above,a special transformer and pump motor are needed.

Washing Unit(max. 2 /Measurement Unit)Sample Lines ........................... 1-5 lines/washing unit• Diameter ................................ 19 or 25 mm ( 3/4”- 63/64”)• Manual sample funnelAmbient Temperature ............... 5-50°C (41-122°F)Dimensions .............................. 165 x 67 x 72 cm(h x w x d) ................................ (65 “ x 26 1/2 “ x 28 1/2 “)Weight ...................................... 190 kg (418,5 lbs)Protection Class ....................... IP 54 (NEMA 3S)

Recommendations for water:

Measurement Warm Cold Deionizedwater water water

Brightness D0, D1, D2 xBr.+ Kappa# D0, D1, D2 xKappa# x x

• If pulp contains alkali before the DO-stage or if there is no O2-stage, warm water is needed.

• Coupling ................................. ISO 7/1 - Rp 1/2• Recommended pipe ............... DN20Cold Water .............................. Chemically purified water• Pressure 500-800 kPa (5-8 bar,

73-116 psi)• Intake; 1 unit ........................... av. 4 l (1 US gal)/minmomentary peak value 17 l (4.5 US gal)/min

• Intake; 2 units ........................ av. 6 l (1.6 US gal)/minmomentary peak value 24 l (6.3 US gal)/min

• Filter ....................................... 100 µmWarm Water ............................ Mill water• Heater recommended to stabilize temperature.• Temperature ........................... 50-60°C (122-140°F)• Allowed variation during sequence ± 2.5°C (± 4.5°F)• Pressure ................................. 300-600 kPa (3-6 bar, 44-87 psi)• Intake; 1 unit ........................... av. 60-105 l/h (16-28 US gal/h)momentary peak value 282 l (74.5 US gal)/h

• Intake; 2 units ......................... av. 105-180 l/h (28-48 USgal/h)momentary peak value 282 l (74.5 US gal) /h

• Filter ....................................... 100 µmDeionized Water ..................... Boiler water specification• Conductivity ............................ < 0,3 mS/m• pH........................................... 6 - 8• KMnO4 consumption .............. < 4 mg/l• SiO2 ........................................ < 0.02 mg/l• Temperature ........................... 18-50°C (64-122°F)• Allowed variation during sequence ± 5°C (± 9°F)• Pressure ................................. 500-800 kPa

(5-8 bar, 72.5-116 psi))• Intake; 1 unit ........................... av. 4 l (1 US gal)/minmomentary peak value 17 l (4.5 US gal)/min

• Intake; 2 units ......................... av. 6 l (1.6 US gal)/minmomentary peak value 24 l (6.3 US gal)/min

Instrument Air• Pressure ................................. 400-600 kPa (4-6 bar, 58-87 psi)• Coupling ................................. ISO 7/1 - Rp 1/2• Recommended pipe ............... DN15Discharge Tube ........................ Diameter 50 mm (1 31/32 “)Cooling System for Electronics• Coupling ................................. ISO 7/1 - Rp 1/2, 2 pcs• Water pressure ....................... max.1600 kPa (16 bar, 232psi)• Water temperature ................. 0-30°C (32-86°F)• See manual for further information.ClO2 Neutralization• Coupling ................................. ISO 7/1 - Rp 1/2• Pressure ................................. 100-800 kPa (1-8 bar,14-116 psi)

Ext.diam. Int.diam. Wall

DN15 21.3 mm [27/32“] 18.1 mm [23 /32“] 1.6 mm [1/16“]DN20 26.9 mm [1 1/16“] 23.7 mm [15/16“] 1.6 mm [1/16“]

B54_09_0_EN.p65 6.2.2002, 16:487

Page 8: kajaaniKAPPAi and kajaaniBRITEi for Fiber Line Optimizationinkom-trade.com/files/kajaani_1.pdf · for Fiber Line Optimization kajaani B54_09_0_EN.p65 1 6.2.2002, ... Manual spot samples

Metso Automation

Field Systems Division

Kehräämöntie 3 , P.O. Box 177

FIN-87101 Kajaani

Finland

Tel. +358 20 483 120

Fax +358 20 483 121

Europe

Levytie 6 , P.O. Box 310

FIN-00811 Helsinki

Finland

Tel. +358 20 483 150

Fax +358 20 483 151

North America

3100 Medlock Bridge Road, Suite 250

Norcross, GA 30071

USA

Tel. +1 770 446 7818

Fax +1 770 242 8386

Latin America

Av. Central 181, Chácaras Reunidas

12238-430 São José dos Campos

SP Brazil

Tel. +55 12 3935 3500

Fax +55 12 3935 3535

Asia Pacific

501 Orchard Road

#05-09 Wheelock Place

238880 Singapore

Tel. +65 735 5200

Fax +65 735 2955

www.metsoautomation.com

B54

09.

0_E©

Met

so A

uto

mat

ion

, 1/2

002

The key to the success

of effective fiber line operation and

total product quality is more than ever depending

on continuous information provided by on-line

analyzers and measurements. Our 30-year-long

history in creating innovative new ways to

measure and control processes has proven to be

an ongoing success. Today 80 % of the world’s

fiber lines are benefiting from our solutions for

bleaching process control. Still today, the Kajaani

sensors and analyzers are the cornerstones of

control solutions that assure cost effective

pulp production with the least

environmental impact.