APPLICATION Control Panel Distribution Systems Generator Sets Motor Control Test Bench ADVANTAGES Reduce Panel Space, Wiring , Installation Time Scale User adjustable reduces inventory PARAMETERS Volts : R-Y Voltage Y-B Voltage B-R Voltage R-N Voltage Y-N Voltage B-N Voltage Amps : R Phase Y Phase B Phase Frequency : System SPECIFICATION System : 3 Phase 4 Wire / 3 Phase 3 Wire Aux. Supply : 230V 110VAC 50Hz (-20% +15%) Burden on Aux. : < 4 VA Voltage Input : 110 / 415 / 440 VAC ( L - L )500Vmax Current Input : 1 Amps / 5 Amps Burden on CT : < 0.2 VA Temp : 0 - 55° C Humidity : < 90% RH ( non condensing) Weight : 500 gms Accuracy : Voltage : 0.5 % of FS + 2 Digit Current : 0.5 % of FS + 2 Digit Frequency : + 0.02 Hz Resolution: Volts : 1V Hz : 0.01 Hz Amps : 0 - 99 : 0.1 A 100 - 999 : 1A > 1000 : 0.01 KA Dimension : 96 x 96mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm FEATURES State of Art Microcontroller Based Design. Built in Solid state selector switch for phase selection Super bright LED display for crystal clear long distance day light viewing All CT ratios user Programmable through front Key Pad. Built in Transducer Compact Size Four Digit Frequency Meter. FAV Meter R Y B N R Y B KA V A Hz 3P4W 50 0 z 6H 2 P KAM-83 1

KAM Catalog

Embed Size (px)

DESCRIPTION

KAM Product Catalog

Citation preview

Page 1: KAM  Catalog

APPLICATION

Control Panel

Distribution Systems

Generator Sets

Motor Control

Test Bench

ADVANTAGESReduce Panel Space, Wiring , Installation Time

Scale User adjustable reduces inventory

PARAMETERS

Volts : R-Y Voltage

Y-B Voltage

B-R Voltage

R-N Voltage

Y-N Voltage

B-N Voltage

Amps : R Phase

Y Phase

B Phase

Frequency : System

SPECIFICATIONSystem : 3 Phase 4 Wire / 3 Phase 3 Wire

Aux. Supply : 230V 110VAC 50Hz (-20% +15%)

Burden on Aux. : < 4 VA

Voltage Input : 110 / 415 / 440 VAC ( L - L )500Vmax

Current Input : 1 Amps / 5 Amps

Burden on CT : < 0.2 VA

Temp : 0 - 55° C

Humidity : < 90% RH ( non condensing)

Weight : 500 gms

Accuracy :Voltage : 0.5 % of FS + 2 Digit Current : 0.5 % of FS + 2 DigitFrequency : + 0.02 Hz

Resolution: Volts : 1V Hz : 0.01 Hz Amps : 0 - 99 : 0.1 A

100 - 999 : 1A > 1000 : 0.01 KA

Dimension : 96 x 96mmDepth ( behind bezzel) : 80 mmPanel Cut out : 92 x 92 mm

FEATURES

State of Art Microcontroller Based Design.

Built in Solid state selector switch for phase selection

Super bright LED display for crystal clear long distance day

light viewing

All CT ratios user Programmable through front Key Pad.

Built in Transducer

Compact Size

Four Digit Frequency Meter.

FAV Meter

R Y B

N

R Y B

KA

V

A

Hz

3P4W 50 0 z6 H2

P

KAM-83

1

Page 2: KAM  Catalog

FEATURES

FAV+ Meter

KAM-83M

P

OL UV OV PRKA

KA 83MM

RV Avg

YI Avg

BL-L

V AvgI Avg

V

I

Hz

SI

I1

I2

I3

3P4W 50 60Hz2

2

Page 3: KAM  Catalog

PARAMETERSVolts : L - L, L - N ( Per Phase & Avg.)

Amps : Per Phase & summation

Frequency : System

Power Factor : Per Phase & Avg

KW : Per Phase & Summation

KVA : Per Phase & Summation

KVAr : Per Phase & Summation

KWh : Import, Export & Summation

KVArh : Capacitive & Inductive

KVAh : Total

ADVANTAGES

APPLICATION

To caution on the Extra Energy Consumption

To indentify inefficiency of Machine / Man

Reduce Panel Space, Wiring , Installation Time

Scale User adjustable reduces inventory

Control Panel

Distribution Systems

Generator Sets

Motor Control

Test Bench

APFC Panel

Energy Management

Process Control & SCADA

SPECIFICATIONAccuracy :

Voltage : 0.5 % of F.S. + 2 DigitCurrent : 0.5 % of F.S. + 2 DigitActive Power : Class1.0 IEC 61036Reactive Power : Class1.0 IEC 61036Apparent Power : Class1.0 IEC 61036Power Factor : + 1° ElectricalActive Energy : Class1.0 IEC 61036Reactive Energy : Class1.0 IEC 61268Frequency : + 0.2 Hz

Dimension : 96 x 96mmDepth ( behind bezzel) : 80 mmPanel Cut out : 92 x 92 mm

System : 3 Phase 4 Wire / 3 Phase 3 Wire

Aux. Supply : 230V / 110 VAC 50Hz (-20% +15%)

Burden on Aux. : < 4 VA

Voltage Input : 110 / 415 / 440 VAC ( L - L )500Vmax

Current Input : 1 Amps / 5 Amps

Burden on CT : < 0.2 VA

Communication : RS485 (Modbus - RTU Protocol) 9600 baud

Temp : 0 - 55° C

Humidity < 90% RH ( non condensing)

Weight : 700 gms

State of Art Microcontroller Based Design.

4 Line Ultra Bright Red LED display to show phase

wise & System Parameters on same page.

Site Programmable CT & PT Ratio.

True RMS measurement.

Auto Scrolling Facility.

Password protection

EEprom retains Energy Parameters on power fail.

Monitors Import & Export Energy.

Computer Interface ( RS 485)

Pulse Output for PLC / SCADA interface

Optional: Data Logging of all Parameters with Date & Time

stamp ( site programmable logging time interval).

FEATURES

POWER ANALYZER

W Wh

VA YAr

VAh VArh

A

K

PF

V(L-L)

V(L-N)

ML1

3P4W 50 60Hz2

HzL2 L3

Avg

Sys

Cal

P

KM-161

3

Page 4: KAM  Catalog

State of Art Microcontroller Based Design.

2 Solid state Relay Out Put configurable for cutoff /

Alarm setting of any Parameter.

Site Programmable CT & PT Ratio.

True RMS measurement.

Auto Scrolling Facility.

Password protection

EEprom retains Energy Parameters on power fail.

Monitors Import & Export Energy.

Computer Interface ( RS 485)

Pulse Output for PLC / SCADA interface

Optional: Data Logging of all Parameters with Date &

Time stamp ( site programmable logging time interval).

FEATURES

System : 3 Phase 4 Wire / 3 Phase 3 Wire

Aux. Supply : 230V / 110 VAC 50Hz (-20% +15%)

Burden on Aux. : < 4 VA

Voltage Input : 110 / 415 / 440 VAC ( L - L )500Vmax

Current Input : 1 Amps / 5 Amps

Burden on CT : < 0.2 VA

Communication : RS485 (Modbus - RTU Protocol) 9600 baud

Temp : 0 - 55° C

Humidity : < 90% RH ( non condensing)

Weight : 700 gms

Accuracy :Voltage : 0.5 % Current : 0.5 % Active Power : Class1.0 IEC 61036Reactive Power : Class1.0 IEC 61036Apparent Power : Class1.0 IEC 61036Power Factor : + 1° ElectricalActive Energy : Class1.0 IEC 61036Reactive Energy : Class1.0 IEC 61036Frequency : + 0.2 Hz

Dimension : 96 x 96mm

Depth ( behind bezzel) : 80 mmPanel Cut out : 92 x 92 mm

SPECIFICATION

PARAMETERS

Volts : L - L, L - N ( Per Phase & Avg.)

Amps : Per Phase & summation

Frequency : System

Power Factor : Per Phase & Avg

KW : Per Phase & Summation

KVA : Per Phase & Summation

KVAr : Per Phase & Summation

KWh : Import, Export & Summation

KVArh : Capacitive & Inductive

KVAh : Total

THD : Volts & Amps

Max. Demand : KVA / KW

ADVANTAGESTo caution on the Extra Energy Consumption

To indentify inefficiency of Machine / Man

Reduce Panel Space, Wiring , Installation Time

Scale User adjustable reduces inventory

Test Bench

APFC Panel

Energy Management

Process Control & SCADA

APPLICATIONControl Panel

Distribution Systems

Generator Sets

Motor Control

POWER ANALYZER Plus

P

CAL P R1 R2

3P4W 50 60Hz2

KM-161P

4

Page 5: KAM  Catalog

Energy Meter

Kwh

REV

3P4W50 60Hz

2

P

KM-34L

5

Page 6: KAM  Catalog

SPECIFICATION

System : 3 Phase 4 Wire / 3 Phase 3 wire

Aux. Supply : 230V / 110VAC 50Hz (-20% +15%)

Burden on Aux. : < 3 VA

Voltage Input : 110 / 415 / 440 VAC ( L - L ) 500 V max

Current Input : 1 Amps / 5 Amps ( Flush Model)

Burden on CT : < 0.2 VA

Temp : 0 - 55° C

Pulse Width : 400 msec. + 50 msec.

Humidity : < 90% RH ( non condensing)

Accuracy : Class1.0 IEC 61036

Dimension :Bezzel: 96 x 96mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm

Weight :500 gms

Resolution :1Amps / 5 Amps : 0.01 & above5A - 50 A : 0.1 & above50A - 500A : 1 & above> 500 Amps : 10

ADVANTAGES

Energy Management System

To caution on the Extra Energy Consumption

CT Ratio Site Programmable reduces inventory

APPLICATION

Energy Audit

Control Panel

Distribution Systems

Generator Sets

State of Art Microcontroller Based Design.

6 Digit Ultra Bright Red LED Display for Clear long distance day light viewing

All CT Ratio Site Programmable.

True RMS measurement.

Resolution site programmable

Pulse Output for PLC / SCADA interface

Reverse indication for wrong wiring polarity

EEprom retains Energy Parameters on power fail.

FEATURES

Energy Meter

3P4W 50 60Hz2 P

INT

REV

MF : 10

KWh

KM-513

6

Page 7: KAM  Catalog

System : 3 Phase 4 Wire / 3 Phase 3 Wire

Aux. Supply : 230V / 110VAC 50Hz (-20% +15%)

Burden on Aux. : < 3 VA

Voltage Input : 415 / 440 VAC ( L - L ) 500 V max

Current Input : 1 Amps / 5 Amps ( Flush Model)

: 60 Amps. Direct continuos ( Din Model)

Burden on CT : < 0.2 VA

Temp : 0 - 55° C

Humidity : < 90% RH ( non condensing)

Accuracy : Class1.0 IEC 61036

Communication : RS485 ( Modbus - RTU Protocol )9600 baud

Pulse Width :400 msec. + 50 msec.

Dimension :Flush Model: Weight : 550 gms Dim.: Bezzel : 96 x 96mm

Depth (behind bezzel) : 80 mmPanel Cut out : 92 x 92 mm

Din Model: Weight : 800 gmsDim.: Size : 150 x 72 mm (L x

B)Height (From wall) : 115 mmBase :35 mm Rail / 2 x m4Screw

Resolution:1Amps / 5 Amps : 0.01< 50 Amps : 0.1< 500 Amps : 1

SPECIFICATION

APPLICATIONEnergy Audit

Control Panel

Distribution Systems

Generator Sets

ADVANTAGESEnergy Management System

To caution on the Extra Energy Consumption

To indentify in efficiency of Machine / Man

Power Billing.

State of Art Microcontroller Based Design.

6 Digit Ultra Bright Red LED Display for Clear long distance

day light viewing

10 Digit Counter ( 2 pages)

All CT Ratio Site Programmable.

True RMS measurement.

Direct 60 Amps. (continuos) Din rail enclosure

Password protection

Computer Interface ( RS 485)

Pulse Output for PLC / SCADA interface

EEprom retains Energy Parameters on power fail.

Reverse Indication for wrong wiring polarity

Optional

Dual Source Energy Meter with individual

Energy Registering Counters for Source1 &

Source 2

FEATURES

Energy Meter Plus

3P4W 50 60Hz2

P

INT

REV

K hW

KM-513P

7

Page 8: KAM  Catalog

Energy Meter

3P4W50 60Hz

2

Kwh

REV

000

ON

KM-34

8

Page 9: KAM  Catalog

1 & 3 Phase Energy Meter(60 Amps. Direct)

(DIN MODEL)

KWh Meter ( Class 1)

Direct Connection up to 60 A max.

Non-Resetable Electromechanical Display

6 + 1 Dgt. ( 0.1 Resolution)

LED indication for Reverse Connection

Power On LED ( flashing ) for Meter Healthyness

LED indication for Energy Consumption

Pulse output Standard feature

Self Power Supply , Aux. Sup. 115 V AC / 230 V AC

FEATURES

Kam Electronic Energy Meter is designed with precision IC's to compute active energy consumption of the load at any power factor under balanced or unbalanced condition.

The meter is designed to accept Voltage & Current input directly, ( 415 V AC L-L) and 60 Amps. (max) respectively.

No need to have any Multiplication Factor and direct energy consumption record is available with 0.1 resolution.

PRODUCT DESCRIPTIONSPECIFICATION

System : 1 Phase 2 wire

Voltage : 230 V AC (P - N ).

Voltage Burden : 0.2 VA max.

Current : 60 Amps.( max) Direct

Current Burden : 0.2 VA max.

Frequency : 50 - 60 Hz

Display : Electro Mech. Counter (6+1 Dgt.)

Accuracy : Class 1 ( EN61036)

LED Indication : A) Power ON

B) Cal. / Int.

C) Reverse Polarity

Housing : ABS Material

Dimension : 105 x 90 x 95 mm ( L x W x H)

Mounting : Din Rail ( 35 mm Rail )

Display : Electro Mech. Counter (6+1 Dgt.)

Accuracy : Class 1 ( EN61036)

Pulse Output : Opto Isolated;

Pulse Width : 400 m Sec.

Housing : ABS Material

Dimension :105 x 90 x 95 mm ( L x W x H)

Mounting : Din Rail ( 35 mm Rail )

System : Three Phase, Unbalanced Load

Voltage : 415 V AC ( L - L ).

Voltage Burden : 0.2 VA max.

Current : 60 Amps.( max) Direct

Current Burden : 0.2 VA max.

Aux. Sup. : 230 V AC ( -15 + 10 % )

Aux.Sup. Burden: 3 VA max.

Frequency : 50 - 60 Hz

SPECIFICATION

KWh

ETRU

MSR

ON

Cal

Rev

aE rth

1P 5 ...0 60Hz2

KWh

TRUE

RMS

ON

Cal

Rev

3 4P W 50...60Hz2

KM-1513C

KM-3513C

9

Page 10: KAM  Catalog

FEATURES

PARAMETERSPower Factor:

R Phase

Y Phase

B Phase

System

SPECIFICATIONSystem : 3 Phase 4 Wire / 3 Phase 3 Wire

Aux. Supply : 230V /110VAC 50Hz (-20% + 15%)

Burden on Aux. : < 3 VA

Voltage Input : 110 / 415 / 440 VAC ( L - L )500Vmax

Current Input : 1 Amps / 5 Amps

Burden on CT : < 0.2 VA

Temp : 0 - 55° C

Humidity : < 90% RH ( non condensing)

Accuracy : + 1° Electrical

Resolution : 0 .01 count

Dimension : Bezzel: 96 x 96mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm

Weight : 500 gms

SPECIFICATIONSystem : 3 Phase 4 Wire / 3 Phase 3 Wire

Aux. Supply : 230V /110VAC 50Hz (-20% +15%)

Burden on Aux. : < 3 VA

Voltage Input : 110 / 415 / 440 VAC ( L - L )500Vmax

Current Input : 1 Amps / 5 Amps

Burden on CT : < 0.2 VA

Temp : 0 - 55° C

Humidity : < 90% RH ( non condensing)

Accuracy : Class 1.0 IEC 61036Dimension : Bezzel : 96 x 96mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mmWeight : 500 gmsResolution: 1A - 10A : 0.001KW 11A - 100A : 0.01 KW 101A - 1000A : 0.1 KW 1001A - 9999A : 1 KW

PARAMETERS

Watts:

R Phase

Y Phase

B Phase

System

State of Art Microcontroller Based Design.

Built in Solid state selector switch for phase selection

Super bright LED display for crystal clear long distance day

light viewing

Built in Transducer

True RMS measurement

FEATURESState of Art Microcontroller Based Design.

Built in Solid state selector switch for phase selection

Super bright LED display for crystal clear long

distance day light viewing

All CT ratios user Programmable through front keypad

Built in Transducer

True RMS measurement

Power Factor Meter

Watt Meter

R

Y

BSYS

OC S

P3 4W 50 z60H2

R

Y

BSYS

KW

3 WP4 50 60Hz2

P

KM-166

KM-2313

10

Page 11: KAM  Catalog

ADVANTAGESReduce Panel Space, Wiring , Installation Time

Scale User adjustable reduces inventory

PARAMETERSPower Factor : R Phase

Y Phase

B Phase

System

Watts : R Phase

Y Phase

B Phase

System

SPECIFICATION

System : 3 Phase 4 Wire / 3 Phase 3 Wire

Aux. Supply : 230V / 110VAC 50Hz (-20% + 15%)

Burden on Aux. : < 4 VA

Voltage Input : 110 / 415 / 440 VAC ( L - L )500Vmax

Current Input : 1 Amps / 5 Amps

Burden on CT : < 0.2 VA

Temp : 0 - 55° C

Humidity : < 90% RH ( non condensing)

Weight : 500 gms

Accuracy :Power Factor : + 1° ElectricalWatts : Class 1.0 IEC 61036

Dimension : Bezzel: 96 x 96mmDepth ( behind bezzel) : 80 mmPanel Cut out : 92 x 92 mm

Resolution : Power Factor : 0.01 Watts : 1A - 10A :

0.001KW 11A - 100A : 0.01 KW 101A - 1000A : 0.1 KW

APPLICATIONControl Panel

Distribution Systems

Generator Sets

Test Bench

State of Art Microcontroller Based Design.

Built in Solid state selector switch for phase selection

Super bright LED display for crystal clear long distance day

light viewing

All CT ratios user Programmable through front Key Pad

Built in Transducer

True RMS measurement

FEATURES

Power Factor & Watt Meter

P43 W 05 60Hz2

P

R Y B SYS

COS

KW

KM-1623

11

Page 12: KAM  Catalog

KM-122

System : 1 Phase

Aux. Supply : 230V / 110VAC 50Hz (-20% +15%)

Burden on Aux. : < 3 VA

Voltage Input : See Range

Temp : 0 - 55° C

Humidity : < 90% RH ( non condensing)

Accuracy : 0.5 % of FS + 2 Digit

Weight : 350 gms

Dimension :

96 x 96 Model: Bezzel : 96 x 96 mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm

48 x 96 Model: Bezzel: 48 x 96 mm Depth ( behind bezzel) : 80 mm Panel Cut out : 44 x 92 mm

Dimension :

96 x 96 Model: Bezzel: 96 x 96 mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm

48 x 96 Model: Bezzel: 48 x 96 mm Depth ( behind bezzel) : 80 mm Panel Cut out : 44 x 92 mm

DC mA : 0 - 200 mA

4 - 20 mA

DC A : 0 - 2 / 20 A

AC mA : 0 - 200 mA

AC A : 0 - 2 / 20 A

FEATURES

3 1/2 Digit - Dual Slope A/D Conversion

Super bright LED display for crystal clear long

distance day light viewing

Built in Transducer

compact size

RangesDC mV : 0 - 200 mV

DC V : 0 - 2 / 20 / 200V

AC mV : 0 - 200 mV

AC V : 0 - 2 / 20 / 100 /

200 / 500 V

SPECIFICATION

SPECIFICATION

System : 1 Phase

Aux. Supply : 230V / 110VAC 50Hz (-20% +15%)

Burden on Aux. : < 3 VA

Current Input : See Range

Temp : 0 - 55° C

Humidity : < 90% RH ( non condensing)

Accuracy : 0.5 % of FS + 2 Digit

Weight : 350 gms.

Ranges

FEATURES

3 1/2 Digit - Dual Slope A/D Conversion

Super bright LED display for crystal clear long

distance day light viewing

Built in Transducer

compact size

1 Phase Volt Meter

1 Phase Ammeter

V

P1 05 06 Hz1

V

1P 50 60Hz1

1P 50 60 zH1

A1P 50 60Hz

2

A

KM-011

12

Page 13: KAM  Catalog

PARAMETERSVolts:

R-Y Voltage

Y-B Voltage

B-R Voltage

R - N Voltage

Y - N Voltage

B - N Voltage

SPECIFICATION

System : 3 Phase 4 Wire / 3 Phase 3 Wire

Aux. Supply : 230V / 110VAC 50Hz (-20% +15%)

Burden on Aux. : < 3 VA

Voltage Input : 110 / 415 / 440 VAC ( L - L )500Vmax

Temp : 0 - 55° C

Humidity : < 90% RH ( non condensing)

Accuracy : 0.5 % of F.S. + 2 Digit

Resolution : 1 Volt

Dimension : Bezzel: 96 x 96mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm

Weight : 400 gms

SPECIFICATIONSystem : 3 Phase 4 Wire / 3 Phase 3 Wire

Aux. Supply : 230V 110VAC 50Hz (-20% +15%)

Burden on Aux. : < 3 VA

Current Input : 1 Amps / 5 Amps

Burden on CT : < 0.2 VA

Temp : 0 - 55° C

Humidity : < 90% RH ( non condensing)

Accuracy : 0.5% of F.S. + 2 Digit

Dimension : Bezzel : 96 x 96mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm

Weight : 450 gms

Resolution : 0 - 99A : 0.1 A100 - 999A : 1A> 1000 A : 0.01 KA

PARAMETERS

Amps:

R Phase

Y Phase

B Phase

FEATURESBuilt in Solid state selector switch for phase selection

Super bright LED display for crystal clear long distance day

light viewing

Built in Transducer

Compact size

FEATURESState of Art Microcontroller Based Design.

Built in Solid state selector switch for phase selection

Super bright LED display for crystal clear long distance day

light viewing

All CT ratios user Programmable, reduces inventory

Built in Transducer

Auto Ranging

3 Phase Volt Meter

3 Phase Ammeter

RY

P43 W 50 60Hz2

V

YB

BR

R

Y

B

3P4W 50 60Hz2

A

KA

R

Y

B

KM-322

KM-031

13

Page 14: KAM  Catalog

State of Art Microcontroller Based Design.

Super Bright Red LED Display for Clear long distance day

light viewing

Four Digit Read out with 0.01 Resolution

Built in Transducer

Optional

A) With High / Low Frequency Cutoff

B) With High & Low Frequency Cutoff

Hysterisis, Delay & Set point site selectable through front

Keypad

FEATURES

SPECIFICATION

Aux. Supply : 230V /110VAC 50Hz (-20% +15%)

Burden on Aux. : < 3 VA

Voltage Input : 30 - 500 VAC

Weight : 450 gms

Temp : 0 - 55° C

Humidity : < 90% RH ( non condensing)

Accuracy : + 0 .02 Hz

Resolution : 0.01 Hz

Dimension :Bezzel: 96 x 96mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm

For Relay Output:Relay status : Energise on TripDelay : 0.1 Sec. to 9.9 Sec.Hysterisis : 0.1 Hz to 3 HzRelay contact : 6A / 230V AC / 28 VDC

APPLICATIONAutomatic Mains Failure Panel

Control Panel

Distribution Systems

Generator Sets

ADVANTAGESTo caution on the Frequency Level

To indentify the faulty Generator

To protect Motors & other Electrical &

Electronic Equipments.

Frequency Meter

Hz

Hi

Low

P

Hz

KM-613P

KM-613

14

Page 15: KAM  Catalog

PVAF METER

KM-1215

43P W 50 60 zH2

Amp

Amp

Amp

KW

v

Hz

L1

L2

L3

L1

L2

L3

P

15

Page 16: KAM  Catalog

FEATURES

SPECIFICATION

APPLICATIONADVANTAGES

Temperature Indicator & Sensor

KAM

KAM

R1

SET

R2 PV

SVo

C

TKAM 100

SET

o

C

KM-209

KM-2019

16

Page 17: KAM  Catalog

Process Indicator

Counter

P

P

P

KM-169

KM-003

17

Page 18: KAM  Catalog

Earth Leakage Relay Plus

Fixed ELR

KM-512R(PS)

KM-512R (F)

TTES

Earth L ak gee a

Relay

RESET

75

60

45

30

5

TAIP

ON

% Dl n

%lD

n

Dt(S)

1052.

51

0.5

0.25

0.15

0.06 0

0.6

lDn(A)

302010

30.

50.

30.

1

0.03

1

5

18

Page 19: KAM  Catalog

Sensitivity RangesModel 1 :

Range : 30mA, 100mA,300mA,

500mA, 1 A & 3A

Model 2 :

Range : 1A, 2A, 3A, 5A,

7.5 A & 10 Amps.

Also user specified Ranges

Zero / Core Balance Current TR.ID ( internal diameter):

35 mm 70 mm 120 mm

Also user specified ID & Rectangular CBCT on request

APPLICATION

Protection :

Control Panel

Feeder / motor

Generator

Transformer

Electrical Dist.

SPECIFICATION

Aux. Supply : 230V / 110VAC 50Hz (-20% +15%)Burden on Aux. : < 3 VATrip Point : +/- 15% of the set rangeDelay : 0.1 , 0.2, 0.3, 0.5, 1 & 3 Seconds.Relays : 2 Nos. (Trip Relay & 50% Alarm Relay) Relay Contacts : Potential Free Contact (NO&NC)SPDT Contact Rating : 6 Amps / 230 V AC/ 28 V DCTemp : 0 - 55 CHumidity : < 90% RH ( non condensing)Dimension : 90 x 45 x 75 mm ( L x B x H)Mounting : Din ( 35 mm rail ) Weight : 350 gms

SPECIFICATIONAux. Supply : 230V / 110VAC 50Hz (-20% +15%)

Burden on Aux. : < 3 VA

Delay : 0.1 Sec. to 10 Sec.

Relay Contacts : 2 Potential Free Contact ( NO&NC)

( Energise on Trip)

Contact Rating : 6 Amps / 230 V AC/ 28 V DC

Temp : 0 - 55 C

Humidity : < 90% RH ( non condensing)

Dimension : 78 x 55 x 97 mm ( L x B x H)Mounting : Din ( 35 mm rail ) / 2 x m4 screw

Weight : 450 gms

Sensitivity RangesRange: 30 - 300 mA , 30 - 3000 mA

300mA - 3Amps,1- 4 Amps

1 - 8 Amps, 1- 10 Amps

Also user specified Ranges

APPLICATIONProtection :

Control Panel

Feeder / motor

Generator

Transformer

Electrical Dist.

FEATURESState of Art Microcontroller Based Design

Bar Graph display to indicate Leakage Current in percentage

Consistent reliability with high accuracy

Trip setting through Dip Switch selection

Time Delay setting through Dip Switch selection

Power ON indication for system Healthiness.

Front Panel Sealing for Tamper proof.

Alarm Relay at 50% of set Range to caution on Leakage current.

FEATURESConsistent reliability with high accuracy

Trip setting through Front Panel Potentiometer

Time Delay user settable

LED indication for healthy / faulty status

Auto / Manual Reset option

Compact size

Earth Leakage Relay Plus

Earth Leakage Relay

KM-512RP

KM-512R

19

Page 20: KAM  Catalog

FEATURES

MORGAIN Inc. manufactures "Anti Condensation' Panel heaters in a wide range. KAM series heaters are extremely robust in construction and provide heating for a wide variety of applications. This type of heaters finds its specific use as "Anti-Condensation Heater" in most of the control gear and switchgear panel applications. The costing being economical makes this ideal for these applications.

SPECIFICATIONS

Kam

ELR Inbuilt CBCT

SPACE HEATERS

KM-512R(IB)

KM-198

20

Page 21: KAM  Catalog

UV, OV & PR Voltage Relay

Under Voltage Relay with DRS

MODELS

FEATURES

SPECIFICATION

APPLICATION

KAM

KAM

KAM

KAM

KAM

KM-2112R

KM-212R

21

Page 22: KAM  Catalog

Current Relay

P

AKM 003R

KA PF AS OV UV

KM 003R

22

Page 23: KAM  Catalog

Voltage & Hz Relay

KM-228R

PR PF Hz AS UVOV

P

VFKM-228R

23

Page 24: KAM  Catalog

Input RangesRange:

CTR / 1 Amps

CTR / 5 Amps.

DC V : 0 - 1 / 5 / 10 V

DC mA : 0 - 1 / 10 / 16 / 20 mA

4 - 20 mA

2 - 10 mA

Input RangesRange:

CTR / 1 Amps

CTR / 5 Amps.

DC V : 0 - 1 / 5 / 10 V

DC mA : 0 - 1 / 10 / 16 / 20 mA

4 - 20 mA

2 - 10 mA

APPLICATIONProtection :

Control Panel

Feeder / motor

Generator

Transformer

Electrical Dist.

APPLICATIONProtection :

Control Panel

Feeder / motor

Generator

Transformer

Electrical Dist.

SPECIFICATION

Aux. Supply : 230V / 110VAC 50Hz (-20% +15%)

Burden on Aux. : < 3 VA

Delay : 0.1 Sec. to 10 Sec.

Set Point : 20% - 120%Relay Contacts : 2 Potential Free Contact (2 NO & NC)

( Energise on Trip)

Contact Rating : 6 Amps / 230 V AC/ 28 V DC

Temp : 0 - 55° C

Humidity : < 90% RH ( non condensing)

Dimension : 78 x 55 x 97 mm ( L x B x H)

Mounting : Din ( 35 mm rail ) / 2 x m4 screw

Weight : 450 gms

SPECIFICATIONAux. Supply : 230V / 110VAC 50Hz (-20% +15%)

Burden on Aux. : < 3 VA

Delay : 0.1 Sec. to 10 Sec.

Set Point : 20% - 80%Relay Contacts : 2 Potential Free Contact (2 NO & NC)

( Energise on Trip)

Contact Rating : 6 Amps / 230 V AC/ 28 V DC

Temp : 0 - 55 C

Humidity : < 90% RH ( non condensing)

Dimension : 78 x 55 x 97 mm ( L x B x H)

Mounting : Din ( 35 mm rail ) / 2 x m4 screw

Weight : 450 gms

FEATURESConsistent reliability with high accuracy

Trip setting through Front Panel Potentiometer

Time Delay user settable

LED indication for healthy / faulty status

Auto / Manual Reset option

Compact size

FEATURESConsistent reliability with high accuracy

Trip setting through Front Panel Potentiometer

Time Delay user settable

LED indication for healthy / faulty status

Auto / Manual Reset option

Compact size

Earth Fault Relay

Over Load Relay

C1

L NA X.SUPU . PIN UT

A M/C1 C2

10% 03 % 0 1S C 0S C- E 1 E

ADEL YSET

AR H A T EE T F UL R LAY

NO COM NC NO COM NC

F

AU LT

Y

TEST RESET

L NAUX.SUP.

INPUT

A / M C1 C2

20% 120% 0-1SEC 10SEC

DELAYSET

E RE YOV R LOAD LA

NO COM NCNO COM NC

F

AU LT

Y

TESTRESET

KM-560R

KM-1512R

24

Page 25: KAM  Catalog

Input RangesDC mV : 0 - 100 mVDC V : 0 - 1 / 5 / 10 VDC mA : 0 - 1 / 10 / 16 / 20 mA

4 - 20 mA 2 - 10 mA

APPLICATIONINPUT to :

Data LoggingPLCSCADAIndicatorsTelemeteringRecoders

SPECIFICATIONAux. Supply : 230V / 110VAC 50Hz (-20% +15%)Burden on Aux. : < 3 VATemp : 0 - 55 CHumidity : < 90% RH ( non condensing)Accuracy : Class 1.0Over Load Cap. : 1.2 x rated voltage continuos

1.5 x rated voltage for 10 sec.Response time : 0.5 Sec. Isolation : 2 KV ( 4 KV on request) Dimension : 78 x 55 x 97 mm ( L x B x H)Mounting : Din ( 35 mm rail ) / 2 x m4 screw

SPECIFICATIONAux. Supply : 230V / 110VAC 50Hz (-20% +15%)

Burden on Aux. : < 3 VA

Temp : 0 - 55 C

Humidity : < 90% RH ( non condensing)

Accuracy : Class 1.0

Response time : 0.5 Sec.

Isolation : 2 KV ( 4 KV on request)

Dimension : 100 x 70 x 112 mm ( L x B x H)Mounting : Din ( 35 mm rail ) / 2 x m4 screw

Weight : Temperature : 500 gms

Watt : 700 gms

Input RangesTemp. Transducer

PT 100 :

Temp.:0 - 50 C

0 - 100 C

0 - 200 C

Input RangesWatt Transducer

1 Phase :- Volt : 0 - 300 V AC Amps : 0 - 8.33 A 3 phase :- Volts : 110 / 415 / 440 V Amps : 1A / 5AOver Load : 1.2 x rated voltage cont.

2 x rated current cont.Output RangesDC V : 0 - 1V ( Burden : 1K )

0 - 5 / 1 - 5 V ( Burden : 5K )

0 - 10 / 2 - 10 V ( Burden : 10K )

DC mA : 0 - 1mA( Burden : 10K )

0 - 5 mA( Burden : 2K )

0- 10 / 2 - 10mA ( Burden : 1K )

0 -20 / 4 - 20mA( Burden : 500 )

Output RangesDC V : 0 - 1V ( Burden : 1K )

0 - 5 / 1 - 5 V ( Burden : 5K )

0 - 10 / 2 - 10 V ( Burden : 10K )

DC mA : 0 - 1mA( Burden : 10K )

0 - 5 mA( Burden : 2K )

0- 10 / 2 - 10mA ( Burden : 1K )

0 -20 / 4 - 20mA( Burden : 500 )

FEATURESHigh Input / Output Isolation ( optical Isolation )

Ripple Free, Stable and High Accuracy Output

External Span & Zero adjustment

Low Internal consumption

compact size

Optional : Multiple output

FEATURES

High Input / Output Isolation ( optical Isolation )

Ripple Free, Stable and High Accuracy Output

External Span & Zero adjustment

Low Internal consumption

Compact size

Signal Isolator / Convertor

Temperature / Watt Transducer

PO ER ONW

L NU P.A X.SU

INPUT

+ -

U TO TPU

+ -

ZERO

SPAN

SIGN LAISOL TA OR

INPUTOUTPUT+ -

P W ONO ER SPAN

+ -

T N U RWAT TRA SD CE

L N

Aux SUP.

KM-199

KM-2032

25

Page 26: KAM  Catalog

Input RangesAC V : 0 - 63.5/ 110 / 230

300 / 440 / 500 VAC

DC V : 0 - 1000 V DC

Input RangesAC A : 0 - 1 A, 5A(direct)

CTR / 1A, CTR / 5A

APPLICATIONINPUT to :

Data Logging

PLC

SCADA

Indicators

Telemetering

Recoders

SPECIFICATION

Aux. Supply : 230V / 110VAC 50Hz (-20% +15%)Burden on Aux. : < 3 VATemp : 0 - 55 CHumidity : < 90% RH ( non condensing)Accuracy : Class 1.0Response time : 0.5 Sec. Over Load Cap. : 2 x rated current continuos

10 x rated current for 10 sec.Isolation : 2 KV ( 4 KV on request)Dimension : 78 x 55 x 97 mm ( L x B x H)Mounting : Din ( 35 mm rail ) / 2 x m4 screw Weight : 400 gms

SPECIFICATIONAux. Supply : 230V / 110VAC 50Hz (-20% +15%)Burden on Aux. : < 3 VATemp : 0 - 55 CHumidity : < 90% RH ( non condensing)Accuracy : Class 1.0Response time : 0.5 Sec. Over Load Cap. : 1.2 x rated Voltage continuos

1.5 x rated Voltage for 10 sec. Isolation : 2 KV ( 4 KV on request)Dimension : 78 x 55 x 97 mm ( L x B x H)Mounting : Din ( 35 mm rail ) / 2 x m4 screw Weight : 400 gms

Output RangesDC V : 0 - 1V ( Burden : 1K )

0 - 5 / 1 - 5 V ( Burden : 5K )

0 - 10 / 2 - 10 V ( Burden : 10K )

DC mA : 0 - 1mA( Burden : 10K )

0 - 5 mA( Burden : 2K )

0- 10 / 2 - 10mA ( Burden : 1K )

0 -20 / 4 - 20mA( Burden : 500 )

Output RangesDC V : 0 - 1V ( Burden : 1K )

0 - 5 / 1 - 5 V ( Burden : 5K )

0 - 10 / 2 - 10 V ( Burden : 10K )

DC mA : 0 - 1mA( Burden : 10K )

0 - 5 mA( Burden : 2K )

0- 10 / 2 - 10mA ( Burden : 1K )

0 -20 / 4 - 20mA( Burden : 500 )

FEATURESStable and High Accuracy Output

External Span & Zero adjustment

Low Internal consumption

Compact size

Optional : Multiple Output

FEATURESStable and High Accuracy Output

External Span & Zero adjustment

Low Internal consumption

compact size

Optional : Multiple Output

AC / DC Voltage Transducer

Current Transducer

OPOWER N

L NPAUX.SU .

I PN UT

+ -

U TO TPU

+ -

Z ROE

SPAN

VOLT GA ETRANS UCERD

POWE ONR

L NS .AUX. UP

PUIN T

+ -

OU PUT T+ -

ZERO

SPAN

CU RENTRR ET ANSDUC R

KM-2220

KM-320

26

Page 27: KAM  Catalog

Engine Protection Unit

VDC

O er pev S ed

Sto Inter l(Secs)p va

Engine Protection un tiON

Start Stop e etR s Ack

KM-516

Motor Protection Relay

P

OL UV OV PRKA

RV Avg

YI Avg

BL-L

V AvgI Avg

V

I

Hz

SI

I1

I2

I3

P3 4W 50 6 Hz02

27

Page 28: KAM  Catalog

Timer

FORWARD REVERSE Timer

KM-020T

KM-618T

ON

VRE

100

100

FOR

0

0

28

Page 29: KAM  Catalog

STAR DELTA Timer

CYCLIC TIMER

NO

01 0

0

Y

KM-194T

KM-003T

ON

REV

100

100

29

Page 30: KAM  Catalog

Customised Panel

DV C

Over S eep d

o n erval( ecs)St p I t S

PEngine rotection unit

a tSt r S opt etResAck

NO

V

A

Hz

R

Y

B

VL-L

KA

V Avg

P

3P4W05 60 zH

2

KM-316

30

Page 31: KAM  Catalog

Customised Panel

KM-613A

Eng e o tio Unitin Pr tec n

S AT RTRESET

OST P

31

Page 32: KAM  Catalog

Customised Panel

KM-316B

A

V(L- )N

W

PF

M

P

V(L- )L

Wh

Vah

Varh

K

R

Var

AV

CAL

Avg

Svs

B

Y

Hz

S

32

Page 33: KAM  Catalog

Customised Panel

KM-316C

P

L1

L2

L3

L1

L2

L3KW

V

Hz

Amp

Amp

Amp

P

L1

L2

L3

L1

L2

L3

KW

V

Hz

3P4W 50 6 Hz02

Amp

Amp

Amp

33

Page 34: KAM  Catalog

PARAMETERSVolts : L - L, L - N ( Per Phase & Avg.)

Amps : Per Phase & summation

Frequency : System

Power Factor : Per Phase & Avg

KW : Per Phase & Summation

KVA : Per Phase & Summation

KVAr : Per Phase & Summation

KWh : Import, Export & Summation

KVArh : Capacitive & Inductive

KVAh : Total

THD : Volts & Amps

Max. Demand : KVA / KW

SPECIFICATIONSystem : 3 Phase 4 Wire / 3 Phase 3 Wire

Aux. Supply : 230V / 110VAC 50 Hz (-20% +15%)

Burden on Aux. : < 4 VA

Voltage Input : 110 / 415 / 440 VAC ( L - L )500Vmax

Current Input : 1 Amps / 5 Amps

Burden on CT : < 0.2 VA

Communication : RS 485 (Modbus - RTU Protocol)

Temp : 0 - 55° C

Humidity : < 90% RH (non condensing)

Accuracy :Voltage : 0.5 % Current : 0.5 % Active Power : Class1.0 IEC 61036Reactive Power : Class1.0 IEC 61036Apparent Power : Class1.0 IEC 61036Power Factor : + 1° ElectricalActive Energy : Class1.0 IEC 61036Reactive Energy : Class1.0 IEC 61036Frequency : + 0.2 Hz

Dimension: 455 x 360 x 150 mm ( L x B x H)

Load Study & Analysis

Energy Audit

Plant Maintance

Power Management

Data logging

APPLICATION

FEATURES

State of Art Microcontroller Based Design.

Suitable for 1 Phase & 3 phase measurement

2 Solid state Relay Out Put configurable for cutoff

setting of any Parameter to give Alarm

Rugged portable casing

Clamp on CT's

Programmable CT & PT Ratio.

True RMS measurement.

Auto Scrolling Facility.

Password protection

EEprom retains Energy Parameters on power fail.

Monitors Import & Export Energy.

Computer Interface ( RS 485) optically isolated

Inbuilt Data Logger for storing all Parameters

with Date & Time stamp for long duration

Audit without manual intervention / operation

Energy Audit Supervisor

KM-5119

34