SENSOR Features Electric wiring Karman Vortex System Flow Sensor KSL-5L/KSL-10L/KSL-30L/KSL-50L Spare cores Red............. Power supply Black .......... GND White......... Flow rate output (0 to 10V DC or 4 to 20 mA or pulse) Orange ..... Temperature output (0 to 10V DC or 4 to 20 mA) Yellow ....... Flow rate alarm Green ........ Temperature alarm Gray Blue Brown • AWM20276: This is a cable with no terminal processing (9 core/0.2 mm 2 /500 mm). • GND should be used as a common ground wire for all other signaling lines including power supply. 4 x 2M4 screw for adapter (hexagon socket head cap screw) 30 (Unit: mm) Adapter for piping Rc3/8 screw (both sides) *2 30 Flow direction Front view Plan view 50 Side view SET TEMP FLOW 68 55 30 19 Countersunk hole for 4-M4 (hexagon socket head cap screw) SET TEMP FLOW 60 *1 Dimensions Cable sheath *2 Height 68.5 68.5 75 75 *1 Width The value varies depending on the adapter type. The size varies depending on the model. Rc3/8 R1/2 BsBM 92 115 Adapter for piping size SUS 98 115 KSL-5L KSL-10L KSL-30L KSL-50L Model Digital display Cable Temperature switch Setting switch Flow rate switch Alarm display LED As a sensor for monitoring the cooling water of equipment, a cumulative total of 60,000 units have been delivered to leading semiconductor and LCD equipment manufactures in the world. Measures and displays the flow rate and temperature. Allows use with high temperature water of 90°C. Analog output Alarm output Digital display

Karman Vortex System Flow Sensor KSL-5L/KSL-10L/KSL-30L/KSL … · 2015. 12. 11. · KSL-5L KSL-10L KSL-30L KSL-50L Model Digital display Cable Temperature switch Setting switch Flow

  • Upload
    others

  • View
    21

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Karman Vortex System Flow Sensor KSL-5L/KSL-10L/KSL-30L/KSL … · 2015. 12. 11. · KSL-5L KSL-10L KSL-30L KSL-50L Model Digital display Cable Temperature switch Setting switch Flow

SENSO

R

Features

Electric wiring

Karman Vortex System Flow Sensor KSL-5L/KSL-10L/KSL-30L/KSL-50L

Spare cores

Red............. Power supplyBlack .......... GNDWhite......... Flow rate output

(0 to 10V DC or 4 to 20 mA or pulse)

Orange ..... Temperature output(0 to 10V DC or 4 to 20 mA)

Yellow ....... Flow rate alarmGreen ........ Temperature alarmGrayBlueBrown

• AWM20276: This is a cable with no terminal processing (9 core/0.2 mm2/500 mm).• GND should be used as a common ground wire for all other signaling lines including power supply.

4 x 2M4 screw for adapter (hexagon socket head cap screw)

30

(Unit: mm)

Adapter for pipingRc3/8 screw (both sides)

*2

30 Flow direction

Front view

Plan view50

Side view

SET

TEMP

FLOW

68

55

3019

Countersunk hole for 4-M4(hexagon socket head cap screw)

SETTEMPFLOW

60

*1

Dimensions

Cable sheath

*2 Height68.568.57575

*1 Width

The value varies depending on the adapter type. The size varies depending

on the model.

Rc3/8R1/2

BsBM92115

Adapter for pipingsize SUS

98115

KSL-5LKSL-10LKSL-30LKSL-50L

Model

Digital display Cable

Temperature switch

Setting switch

Flow rate switch

Alarm display LED

● As a sensor for monitoring the cooling water of equipment, acumulative total of 60,000 units have been delivered toleading semiconductor and LCD equipment manufactures inthe world.

● Measures and displays the �ow rate and temperature.

● Allows use with high temperature water of 90°C.

● Analog output

● Alarm output

● Digital display

Page 2: Karman Vortex System Flow Sensor KSL-5L/KSL-10L/KSL-30L/KSL … · 2015. 12. 11. · KSL-5L KSL-10L KSL-30L KSL-50L Model Digital display Cable Temperature switch Setting switch Flow

SEN

SOR

Order format

Speci�cations Flow rate characteristics

Caution:

• The �ow rate characteristics are temperature dependent as shown in the above graph.

To maintain accuracy, secure a straight-pipe length of 7D or more on the upstream side and 5D or more on the downstream side. Moreover, be sure to install valves, branches, gauges, etc. on the downstream side.(D: Diameter. For 5L, D = 4.1 mm; for 10L, D = 5.8 mm; for 30L, D = 10 mm; for 50L, D = 12 mm.)

0.5 1 2 3 4 50

5

1011

4

12

20

0

Volta

ge o

utpu

t (V

)

Curr

ent o

utpu

t (m

A)

Normal te

mperature

KSL-5L

KSL-10L

3 6 12 18 24 300KSL-30L

KSL-50L

90˚C

Flow rate (L/min)

1 2 4 6 8 100

5 10 20 30 40 500

Model

Flow rate

Temperature detectionrange

OutputFlow rate

Temperaturemeasurement

Alarm output

Maximum operatingpressure

Fluid temperature

Ambienttemperature

Flow direction

Power supply

Currentconsumption

Accuracy

Material of body

Materialsof detectors

Materialof adapter

Applicable �uid

Sealing O-ring

Couplingof pipings

Cable

KSL-5L

0 to 99˚C

0 to 10V, 4 to 20mA, Pulse

0 to 10V, 4 to 20mA

KSL-30L

0.5 to 5 L/min 1.5 to 10 L/min 5 to 30 L/min 7 to 50 L/min

KSL-10L KSL-50L

Open collector A or B (�ow rate, temperature)

1 MPa (below 10kgf/cm 2)

0 to 90˚C

0 to 40˚C (Non-freezing)

Speci�ed direction

12V DC±5% or 24V DC±10% (factory setting)

30 mA max. (70 mA max. in 4 to 20 mA speci�cation)

FS±2.0%

PPS

Flow rate detector: PPS, temperature detector: SUS304

SUS or BsBM + Ni plating

Industrial water or service water

Fluororubber

Rc 3/8 or Rc1/2

AWM20276 9 cores/0.2 mm 2/500mm

5L

50L

0.5 to 5L/min

10L1.5 to 10L/min

30L

7 to 50L/min

5 to 30L/min

KSL

24V

12V A

B

A

B B

S

Flow ratePowersupply

Alarm AdapterMaterial

DC12V

DC24V

SUS

BsBMNi plating

3/8

1/2

Adapterconnection

port dia.Flow rate Temperature

* The alarm is conductive when the open collector is ON and non-conductive when it is OFF.

* The alarm for the �ow rate and that for the temperature can be set independently.

Alarm

Measurement valueA B

Higher than the setting value

Lower than the setting value

Green lamp

Red lamp

ON OFFGreen lamp

Red lamp

ONOFF

KSL-5L-24V-V-A-B-S-3/8Example

De�nition of alarm output and display LED

* "P" (pulse output) can be speci�ed only for 5L and 30L and cannot be speci�ed for 10L and 50L.* When the output of the �ow rate is set to "P" (pulse output), the temperature output is "V" or "I."

In temperature output, the pulse output cannot be selected. (The order format of the output is "PV" or "PI.")Example: KSL-5L-24V-PV-A-B-S-3/8

* The "DPM" (DPM connection) is a pulse speci�cation for using the external display "DPM" speci�ed by REGAL JOINT.* For 50L, only 1/2 can be speci�ed as the adapter connection port diameter.* To improve the performance, the shape and speci�cations are subject to change without prior notice.

Output

Flow rate Temperature

V

I

P

0 to 10V

4 to 20mA

Pulse output

DPMDPM connection

V

I

0 to 10V

4 to 20mA

*