2
Product Specification Profile: Exterior: Shadowline or flat Interior: Shadowline Embossing: Exterior: Stucco or non-embossed Interior: Stucco or non-embossed Gauge: Exterior: 26, 24, 22 ga Interior: 26, 24, 22 ga Width: 24”, 30”, 36”, 40”, 42” Thickness: 2”, 2.5”, 3”, 4”, 5”, 6” Length: 8’ - 53’ Reveal option: 3 /8” to accommodate rail Orientation: Vertical or horizontal Post fabrication: N/A R-value: ≈ 7.2 per inch per ASTM C518 @ 75˚F ≈ 8.25 per inch per ASTM C518 @ 35˚F Unique KarrierRail KarrierPanel utilizes a Kingspan designed unique rail. This stable and secure structural rail safely transmits positive loads from the multiple façades to the structural supports behind the insulated panels. Similarly, through fasteners secure the exposed rail edge, ensuring that the system safely handles negative loads as well. The rail has been developed to fully integrate with Kingspan’s KS series panel joint. This rail system does not penetrate the air vapor barrier and enables multiple types of rain screens to be attached. Installation is quick, simple and easy, as the rail is installed during normal panel installation, and is secured using standard panel fasteners in a one step procedure. The standard rail configuration is 16 gauge Galvalume, 50 KSI steel. Available in various lengths with a 1, 2 and 3 inch bearing surface. Customer options Kingspan offers a full spectrum of vibrant colors for every color scheme. The high performance coatings provide long-life protection, color and gloss retention. Custom color matching is available to meet individual building designs and creative freedom. 1 KarrierPanel Data Sheet Universal Barrier Wall Solution 24” - 42” Shadowline Shadowline Interior Face Exterior Face 2”- 6”

KarrierPanel Data Sheet

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: KarrierPanel Data Sheet

Product SpecificationProfile: Exterior:Shadowlineorflat Interior: Shadowline

Embossing: Exterior:Stuccoornon-embossed Interior: Stuccoornon-embossed

Gauge: Exterior:26,24,22ga Interior: 26,24,22ga

Width: 24”,30”,36”,40”,42”

Thickness: 2”,2.5”,3”,4”,5”,6”

Length: 8’-53’

Revealoption: 3/8”toaccommodaterail

Orientation: Verticalorhorizontal

Postfabrication:N/A

R-value: ≈7.2perinchperASTMC518@75˚F ≈8.25perinchperASTMC518@35˚F

Unique KarrierRailKarrierPanelutilizesaKingspandesigneduniquerail.Thisstableandsecurestructuralrailsafelytransmitspositiveloadsfromthemultiplefaçadestothestructuralsupportsbehindtheinsulatedpanels.Similarly,throughfastenerssecuretheexposedrailedge,ensuringthatthesystemsafelyhandlesnegativeloadsaswell.TherailhasbeendevelopedtofullyintegratewithKingspan’sKSseriespaneljoint.Thisrailsystemdoesnotpenetratetheairvaporbarrierandenablesmultipletypesofrainscreenstobeattached.

Installationisquick,simpleandeasy,astherailisinstalledduringnormalpanelinstallation,andissecuredusingstandardpanelfastenersinaonestepprocedure.Thestandardrailconfigurationis16gaugeGalvalume,50KSIsteel.Availableinvariouslengthswitha1,2and3inchbearingsurface.

Customer optionsKingspanoffersafullspectrumofvibrantcolorsforeverycolorscheme.Thehighperformancecoatingsprovidelong-lifeprotection,colorandglossretention.Customcolormatchingisavailabletomeetindividualbuildingdesignsandcreativefreedom.

1

KarrierPanel Data SheetUniversal Barrier Wall Solution

24”-42”

Shadowline

Shadowline

InteriorFace

ExteriorFace

2”-6”

Page 2: KarrierPanel Data Sheet

Test Procedure ResultsFire ASTME84 FlameSpread:25orLess/SmokeDeveloped:450orLess

CAN/ULC-S102 FlameSpread:20/SmokeDeveloped:350forpanelwithfacings

CAN/ULC-S127 FlameSpread:<500forfoamcore

NFPA259 Testedforpotentialheatofbuildingmaterials

NFPA268 Passed:Standardtestmethodfordeterminingignitabilityofexteriorwallassemblies usingaradiantheatenergysource

NFPA285 Passed:StandardFireTestMethodforEvaluationofFirePropagationCharacteristics ofExteriorNon-Load-BearingWallAssembliesContainingCombustibleComponents

Structural ASTME72 Vacuumchambertested.Panelload/spananddeflectiontablesareavailable

Thermal ASTMC518Transmission

Air Infiltration ASTME283 0.003CFM/ft2ofPanelAreaat6.24psf

Water ASTME331 Nouncontrolledwaterpenetrationat20psfdifferentialpressure

AAMA501.1 Dynamicwaterpressuretesting–nosignofwaterleakageat15psf

Fatigue Cyclictesttopositiveandnegative Thepanelsexceeded2millionalternatecycleswithoutfailureordamage windloadingto±L/180deflection

Bond Strength ASTMD1623 Panelstestedfortensilebondstrengthofmetaltofoam

Sampleplacedinanautoclavedeviceandpressurizedto2PSIat212°Ffor21/2hrs

Noskindelaminationwithdirectpulloffpressureupto1188psf

2

Performance Testing and ApprovalsKingspaninsulatedpanelsmeetspecificbuildingenvelopeperformancecriteriaandrequirementsstipulatedbyUSandCanadianbuildingcodes.PanelsaretestedinaccordancewithUL,ULCandASTMapprovalstandards,testingmethodsandprocedures.KingspaninsulatedpanelsarelistedbyWarnockHersey.

KarrierPanel Data SheetUniversal Barrier Wall Solution

Kingspan North AmericaDeLand,FL:386-626-6789 Modesto,CA:209-531-9091Caledon,ON:905-951-5600 Langley,BC:604-607-1101www.kingspanpanels.comFortheproductofferinginothermarketspleasecontactyourlocalsalesrepresentativeorvisitwww.kingspanpanels.com

Carehasbeentakentoensurethatthecontentsofthispublicationareaccurate,butKingspanLimitedanditssubsidiarycompaniesdonotacceptresponsibilityforerrorsorforinformationthatisfoundtobemisleading.Suggestionsfor,ordescriptionof,theenduseorapplicationofproductsormethodsofworkingareforinformationonlyandKingspanLimitedanditssubsidiariesacceptnoliabilityinrespectthereof.

Issue4:07/2018

Thermal Performance at 75˚Thickness U-Factor R-Value

2 0.07 14.42.5 0.06 18.03 0.05 21.64 0.03 28.85 0.03 36.06 0.02 43.2

Thermal Performance at 35˚Thickness U-Factor R-Value

2 0.06 162.5 0.05 203 0.04 244 0.03 325 0.03 406 0.02 48