KD-2900 Cryostat Microtome FeaturesDouble-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate cooling setting of freeze chamber and specimen block. Imported step motor driving table and specimen feeding systems. LCD screen shows sample travel,section thickness,fuction control,temperature control,date,time,temperature,time on/off,fumigating and defrost and so on. Streamline external design,elegant appearance. Big freeze chamber,rapid specimen freezing table. Humanity sleep mode,after initializing,the teperature in freezing chamber can be controlled -1-10 ,when stop initializing,temperature can reach to working temperature within 10 minutes. User-friendly specimen clamp,easy and secure handwheel system. Instant temperature display, Without fluorine refrigeration technology, fumigation Ultraviolet disinfection. Time of power on/off,defrost,fumigationg disinfection can be set anytime in one week. Specimen retraction fuction,motorized specimen feeding systems.fast forward;trimming/sectioning button can be changed easily and conveniently. Technical Specifications: Freezing chamber temperature range: -1℃~-30Freezing table temperature: -40Lowest temperature of peltier unit on freeze shelf: -60Section thickness range: 1μm-30μm,in 1 μm increment 30μm-60μm,in 5μm increment Trimming thickness range: 195μm Minumum setting value: 1μm Maximum specimen size: 50mm Vertical stroke: 70mm,Object feed: 28mm Spection retraction range: 20μm Angle of specimen clamp can be adjusted on 8 degrees X/Y axis Freezing table can put 10 pcs specimen block Speed of specimen feeding: 0.8mm/sec Temperature of freezing chamber can reach down to -30within 30 minutes Frostless glass door Working Voltage: AC220V 50Hz / AC110V 60Hz Power draw: 600VA Dimension: 660x640x1130mm Net weight: 148kg

KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

  • Upload
    others

  • View
    30

  • Download
    0

Embed Size (px)

Citation preview

Page 1: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-2900 Cryostat Microtome

Features:

■ Double-compressor semi automatic cryostat.

Computer temperature control,manual and automated

defrost fuction,separate cooling setting of freeze chamber

and specimen block.

■Imported step motor driving table and specimen

feeding systems.

■ LCD screen shows sample travel,section

thickness,fuction control,temperature

control,date,time,temperature,time on/off,fumigating and

defrost and so on.

■Streamline external design,elegant appearance.

■ Big freeze chamber,rapid specimen freezing

table.

■ Humanity sleep mode,after initializing,the

teperature in freezing chamber can be controlled -1~

-10℃,when stop initializing,temperature can reach to

working temperature within 10 minutes.

■User-friendly specimen clamp,easy and secure

handwheel system.

■ Instant temperature display, Without fluorine

refrigeration technology, fumigation , Ultraviolet

disinfection.

■ Time of power on/off,defrost,fumigationg disinfection can be set anytime in one week.

■Specimen retraction fuction,motorized specimen feeding systems.fast forward;trimming/sectioning button

can be changed easily and conveniently.

Technical Specifications:

■Freezing chamber temperature range: -1℃~-30℃

■Freezing table temperature: -40℃

■Lowest temperature of peltier unit on freeze shelf: -60℃

■Section thickness range: 1μm-30μm,in 1 μm increment

30μm-60μm,in 5μm increment

■Trimming thickness range: 1~95μm

■Minumum setting value: 1μm

■Maximum specimen size: 50mm

■Vertical stroke: 70mm,Object feed: 28mm

■Spection retraction range: 20μm

■Angle of specimen clamp can be adjusted on 8 degrees X/Y axis

■Freezing table can put 10 pcs specimen block

■Speed of specimen feeding: 0.8mm/sec

■Temperature of freezing chamber can reach down to -30℃ within 30 minutes

■Frostless glass door

■Working Voltage: AC220V 50Hz / AC110V 60Hz

■Power draw: 600VA

■Dimension: 660x640x1130mm

■Net weight: 148kg

Page 2: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-2800 Cryostat Microtome

Features:

■Simple-compressor semi automatic cryostat. Computer

temperature control,manual and automated defrost

fuction,freezing temperature can be set in freezing chamber.

■ Imported step motor driving table and specimen

feeding systems

■ LCD screen shows sample travel,section

thickness,fuction control,temperature

control,date,time,temperature,time on/off,fumigating and

defrost and so on.

■Streamline external design,elegant appearance

■Big freeze chamber,rapid specimen freezing table

■Humanity sleep mode,after initializing,the teperature

in freezing chamber can be controlled -1~-10℃,when stop

initializing,temperature can reach to working temperature

within 10 minutes.

■ User-friendly specimen clamp,easy and secure

handwheel system

■ Instant temperature display, Without fluorine

refrigeration technology, fumigation disinfection

■Time of power on/off,defrost,fumigationg disinfection can be set anytime in one week.

■Specimen retraction fuction,motorized specimen feeding systems.fast forward;trimming/sectioning button

can be changed easily and conveniently.

Technical Specifications:

■Freezing chamber temperature range: -1℃~-30℃

■Freezing table temperature: -40℃

■Lowest temperature of peltier unit on freeze shelf: -60℃

■Section thickness range: 1μm-30μm,in 1 μm increment

30μm-60μm,in 5μm increment

■Trimming thickness range: 1~95μm

■Minumum setting value: 1μm

■Maximum specimen size: 35 x 35mm

■Vertical stroke: 70mm,Object feed: 28mm

■Spection retraction range: 20μm

■Speed of specimen feeding: 0.8mm/sec

■Temperature of freezing chamber can reach down to -30℃ within 30 minutes

■Frostless glass door

■Working Voltage: AC220V 50Hz / AC110V 60Hz

■Power Draw: 600VA

■Dimension: 660x640x1130mm

■Net weight: 125kg

Page 3: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-3368AM-Ⅲ Automated Microtome+Fast Freezing machine

This model combime

KD-3368AM Fully-auto Microtome

and KD-III fast freezing

machine.KD-III adopt high-power

semi-conductor freezing system and

advanced nano meterial.LCD shows

setting and current

temperature,self-temperature

control,self-protection systems an

defrost fuction etc.

This model adopt streamline

design,advanced fuction,stable

performance,user-friendly.Specimen

feed drive is controled by intelligent

control system..Precise electrical

mechanical design,Ergonomic

concept.

Technical Specifications:

■Section thickness setting range: 0.5~100μm

0.5~2μm increment 0.5μm

2~10μm increment 1μm

10~20μm increment 2μm

20~100μm increment 5μm

■Trimming thickness setting range:1~600μm

1~10μm increment 1μm

10~20μm increment 2μm

20~100μm increment 10μm

100~600μm increment 50μm

■Minimum setting value: 0.5μm

■Object feed: 26mm

■Vertical stroke: 60mm

■Specimen retraction range: 20μm

■Specimen clamp rotated at an angle of 360 degrees.

■Maximum specimen size: 50 x 50mm

■Precision error: ±5%

■Pre-setting temperature range: ambient~-55℃

■Maximum temperature range for Cryo-plate ≥60℃

■Maximum temperature range for Cryo-probe: ≥50℃

■Maximum size of Cryo-pate: 45 x 40mm

■Pre-setting and current temperature shown in LCD

■Best section angle between Cryo-proble and section blade is 60 degrees

■Temperature of defrost display,pre-setting temperature can be stored itself afte working

■Temperature of section can be reached after freezing within 4~7 minutes

■Quick freezing systems,energy-saving

■Dual fuction section: freezing and paraffin use

■Working voltage:AC220V 50Hz, AC110V 60Hz

■Power draw:150VA (KD-3368AM);300VA (KD-Ⅲ)

■Dimension:580x60x310mm(KD-3368AM),420x190x410mm(KD-Ⅲ)

■Net weight:35kg(KD-3368AM) 8kg(KD-Ⅲ)

Page 4: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-3368AM Automated Microtome

This model is devoloped based on

semi-automatic microtome,it combine

advanced and patented technology,and it's very

good choice for histopathology research.

This model adopt streamline

design,advanced fuction,stable

performance,user-friendly.Specimen feed drive

is controled by intelligent control

system.Manual and automated sectioning

mode.Speed of sectioning can be

adjusted;emergency Stop(E-stop).Precise

electrical mechanical design,Ergonomic

concept.

Features:

■Advanced driving systems,fuctions of section,trimming,fast forward,backward etc

■LCD screen shows section and trimming thickness range,numbers of section and trimming

■Section and trimming mode can be finshed by controlling systems

■Handwheel can be locked at any position to assure user's safety

■Large waste tray,easy to unload

■Universal cassette clamp and standard specimen clamp;emergency stop systems

■Manual or fully automated section mode

■Fully-automated section has two modes: single and continuous;speed of section can be adusted

■Section and trimming mode can be exchanged easily

■Emergency stop system,overload protection fuction,sleep mode protection

■Emergency brake system

Technical Specifications:

■Section thickness range: 0.5~100μm

0.5~2μm increment 0.5μm

2~10μm increment 1μm

10~20μm increment 2μm

20~100μm increment 5μm

■Trimming thickness range: 1~600μm

1~10μm increment 1μm

10~20μm increment 2μm

20~100μm increment 10μm

100~600μm increment 50μm

■ Minimum setting value: 0.5μm

■Object feed: 28mm

■Vertical stroke: 60mm

■Specimen retraction range: 20μm

■Specimen clamp rotated at an angle of 360 degrees.

■Maximum specimen size: 50 x 50mm

■Precision error: ±5%

■Working Voltage: AC220V 50Hz / AC110V 60Hz

■Power Draw: 150VA

■Dimension: 580x360x310mm

■Net weight: 35kg

Page 5: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-3368-Ⅲ Semi-automatic Microtome+Fast Freezing machine

This model combime KD-3368 Automated Microtome and KD-III fast freezing machine.KD-III adopt

high-power semi-conductor freezing system and advanced nano meterial.LCD shows setting and current

temperature,self-temperature

control,self-protection systems an

defrost fuction etc.

This model adopt streamline

design,advanced fuction,stable

performance,user-friendly.Specime

n feed drive is controled by

intelligent control system..Precise

electrical mechanical

design,Ergonomic concept.

Technical Specifications:

■ Section thickness range:

1~100μm

1~10μm increment 1μm

10~20μm increment 2μm

20~100μm increment 5μm

■Trimming thickness range:1~100μm

■Minimum setting value: 1μm

■Object feed: 28mm

■Vertical stroke: 60mm

■Specimen retraction range: 20μm

■Specimen clamp rotated at an angle of 360 degrees

■Maximum specimen size: 50 x 50mm

■Precision error: ±5%

■Pre-setting temperature range: ambient~-55℃

■Maximum temperature range for Cryo-plate ≥60℃

■Maximum temperature range for Cryo-probe: ≥50℃

■Maximum size of Cryo-pate: 45 x 35mm

■Pre-setting and current temperature shown in LCD

■Best section angle between Cryo-proble and section blade is 60 degrees

■Temperature of defrost display,pre-setting temperature can be stored itself afte working

■Temperature of section can be reached after freezing within 4~7 minutes

■Quick freezing systems,energy-saving

■Dual fuction section: freezing and paraffin use

■Working Voltage: AC220V 50Hz

AC110V 60Hz

■Dimension:580x330x310mm (KD-3368)

420x190x410mm(KD-Ⅲ)

■Net weight:28kg(KD-3368) 8kg(KD-Ⅲ)

Page 6: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-3368 Semi-automatic Microtome

KD-3368 Semi-automatic microtome is new model after KD-3358 microtome,This model is devoloped based

on semi-automatic microtome,it combine advanced

and patented technology,and it's very good choice

for histopathology research.

This model adopt streamline design,advanced

fuction,stable performance,user-friendly.Specimen

feed drive is controled by intelligent control

system.Manual and automated sectioning

mode.Speed of sectioning can be

adjusted;emergency Stop(E-stop).Precise electrical

mechanical design,Ergonomic concept.

Features:

■ Advanced driving systems,fuctions of

section,trimming,fast forward,backward etc

■LCD screen shows section and trimming thickness range,numbers of section and trimming

■Section and trimming mode can be finshed by controlling systems

■Handwheel can be locked at any position to assure user's safety

■Large waste tray,easy to unload

■Universal cassette clamp and standard specimen clamp;emergency stop systems

Technical Specifications:

■Section thickness range: 1~100μm

1~10μm increment 1μm

10~20μm increment 2μm

20~100μm increment 5μm

■Trimming thickness range:1~100μm

■Minimum setting value: 1μm

■Object feed: 28mm

■Vertical stroke: 60mm

■Specimen retraction range: 20μm

■Specimen clamp rotated at an angle of 360 degrees.

■Maximum specimen size: 50 x 50mm

■Precision error: ±5%

■Working Voltage: AC220V 50Hz AC110V 60Hz

■Power draw: 50VA

■ Dimension:580x330x310mm

■Net weight:28kg

Page 7: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-3358-III Semi-automatic Microtome+Fast Freezing machine

This model combime KD-3358

Automated Microtome and KD-III

fast freezing machine.KD-III adopt

high-power semi-conductor freezing

system and advanced nano

meterial.LCD shows setting and

current emperature,self-temperature

control,self-protection systems an

defrost fuction etc.

This model adopt streamline

design,advanced fuction,stable

performance,user-friendly.Specimen

feed drive is controled by intelligent

control system..Precise electrical mechanical design,Ergonomic concept.

echnical Specifications:

■Section thickness range: 0.25~60μm

0.25~1μm increment 0.25μm

1~10μm increment 1μm

10~20μm increment 2μm

20~60μm increment 5μm

■Trimming thickness range: 0.25~60μm

■Minimum setting value: 0.25μm

■Object feed: 28mm

■Vertical stroke: 60mm

■Maximum specimen size: 50 x 50mm

■Precision error: ±5%

■Pre-setting temperature range: ambient~-55℃

■Maximum temperature range for Cryo-plate ≥60℃

■Maximum temperature range for Cryo-probe: ≥50℃

■Maximum size of Cryo-pate: 45 x 4mm

■Pre-setting and current temperature shown in LCD

■Best section angle between Cryo-probe and section blade is 60℃

■Temperature of defrost display,pre-setting temperature can be stored itself afte working

■Temperature of section can be reached after freezing within 4~7 minutes

■Dual fuction section: freezing and paraffin use.

■Working Voltage: AC220V 50Hz AC110V 60H

■Dimension:150VA(KD-3358)、300VA(KD-Ⅲ)

■Net weight:24kg(KD-3358) 8kg(KD-Ⅲ)

Page 8: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-3358Semi-automatic Microtome

KD-3358 Semi-automatic microtome is new model after KD-202,KD-1508,KD-2258This model adopt

advanced,modern histopathology research technology.It has stable performance,ergonomic concept,.Main

spare parts are imported from overseas.This model stand for very advanced technology and new development

direction of histopathology research.

Features:

■Advanced driving systems,fuctions of

section,trimming,fast forward,backward etc

■ LCD screen shows section and

trimming thickness range,numbers of section

and trimming

■Section and trimming mode can be

finshed by controlling systems

■ Handwheel can be locked at any

position to assure user's safety

■Large waste tray,easy to unload

■Universal cassette clamp and standard

specimen clamp;emergency stop systems

Technical Specifications:

■Section thickness range: 0.25~60μm

0.25~1μm increment 0.25μm

1~10μm increment 1μm

10~20μm increment 2μm

20~60μm increment 5μm

■Trimming thickness range:0.25~60μm

■Minimum setting value: 0.25μm

■Object feed: 28mm

■Vertical stroke: 60mm

■Maximum specimen size: 50 x 50mm

■Precision error: ±5%

■Working Voltage: AC220V 50Hz

AC110V 60Hz

■Dimension:150VA

■Net weight:24kg

Page 9: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-2268-Ⅲ Manual Microtome+Fast Freezing machine

This model combime

KD-2268 Manual Microtome and

KD-III fast freezing

machine.KD-III adopt high-power

semi-conductor freezing system

and advanced nano meterial.LCD

shows setting and current

temperature,self-temperature

control,self-protection systems an

defrost fuction etc.

This model adopt streamline

design,advanced fuction,stable

performance,user-friendly.Specime

n feed drive is controled by

intelligent control system..Precise

electrical mechanical design,Ergonomic concept.

Technical Specifications:

■Section thickness range: 0~60μm

0~20μm increment 1μm

20~60μm increment 5μm

■Minumum Setting value:1μm

■Precision Error:±5%

■Maximum Specimen Size:60×50mm

■Trimming Setting Mode:15μm or 35μm

■Specimen Retraction Range: 90μm

■Specimen retraction range of 90μm can be shut off

■Object feed: 30mm

■Vertical stroke: 70mm

■Angle of specimen clamp can be adjusted on 8 degrees X/Y axis

■Pre-setting temperature range: ambient~-55℃

■Maximum temperature range for Cryo-plate ≥60℃

■Maximum temperature range for Cryo-probe: ≥50℃

■Maximum size of Cryo-pate: 45 x 40mm

■Pre-setting and current temperature shown in LCD

■Best section angle between Cryo-proble and section blade is 60 degrees

■Temperature of defrost display,pre-setting temperature can be stored itself afte working

■Temperature of section can be reached after freezing within 4~7 minutes

■Quick freezing systems,energy-saving

■Dual fuction section: freezing and paraffin use

■Working Voltage: AC220V 50Hz, AC110V 60Hz

■Power draw:50VA(KD-2258S)、300VA(KD-Ⅲ)

■Dimension: 570x500x300mm(KD-2268),420x190x410mm(KD-Ⅲ)

■Net weight:33kg(KD-2268) 8kg(KD-Ⅲ)

Page 10: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-2268 Manual Microtome

KD-2268 microtome is

new-developed model,it offers features

different from others.This machine

adopt advanced guide

rail,high-precision lead srews,retraction

fuction,section and trimming mode.

This model has professional

design,secure

struction,high-precision,stable

preformance.It's prefectly suited for

those who expect precision sectioning.

Features:

■ Ergonomical conception of

devise,no feeling of tire for routine

operation

■Good section result whether by use of Standard Steel Knife or Disposable Blade

■Specimen clamp positioned at 8 X/Y precision orientation system

■Handweel system allow the handwheel locked at any position

■Specimen retraction fuction(this fuction can be shut),Cutting and trimming modes

■Course feed handwheel systems,closer to user to protect fatigue-free section

■Exact zero position precise orientation systems,easy to operate

■Red Knife guard to avoid any damage to user,and easy to change disposable blade

■Blade holder can be moved sidewise,no need to move blade

■An integrated storage tray (not supplied with basic instrument) ensures that ancillary tools are on

hand at all times

■Large Waste tray,easy to clean and unload

Technical Specifications:

■Section thickness range:0~60μm

■Setting value:0~20μm increment 1μm

20~60μm increment 5μm

■Minumum Setting value:1μm

■Precision Error:±5%

■Maximum Specimen Size:60x50mm

■Trimming Setting Mode:15μm or 35μm

■Specimen Retraction Range: 90μm

■Specimen retraction range of 90μm can be shut off

■Object Feed: 30mm,Vertical Stroke: 70mm

■Specimen Orientation System: 8 X/Y

■Dimension: 570mmx500mmx300mm

■Net Weight: 33kg

Page 11: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-2258S-Ⅲ Semi-automatic Microtome+Fast Freezing machine

This model combime

KD-2258S Semi-automatic

Microtome and KD-III fast

freezing machine.KD-III adopt

high-power semi-conductor

freezing system and advanced

nano meterial.LCD shows

setting and current

temperature,self-temperature

control,self-protection systems

an defrost fuction etc.

This model adopt

streamline design,advanced

fuction,stable

performance,user-friendly.Spec

imen feed drive is controled by

intelligent control system..Precise electrical mechanical design,Ergonomic concept.

Technical Specifications:

■Section thickness range: 0.5~100μm

0.5~2μm increment 0.5μm

2~10μm increment 1μm

10~20μm increment 2μm

20~100μm increment 5μm

■Trimming thickness range:0~100μm

■Precision error: ±5%

■Minimum setting value: 0. 5μm

■Object feed: 26mm

■Vertical stroke: 52mm

■Maximum specimen size: 60 x 50mm

■LCD screen shows thikness of sectioning,easy to identify.

■Pre-setting temperature range: ambient~-55℃

■Maximum temperature range for Cryo-plate ≥60℃

■Maximum temperature range for Cryo-probe: ≥50℃

■Maximum size of Cryo-pate: 45 x 40mm

■Pre-setting and current temperature shown in LCD

■Best section angle between Cryo-proble and section blade is 60 degrees

■Temperature of defrost display,pre-setting temperature can be stored itself afte working

■Temperature of section can be reached after freezing within 4~7 minutes

■Dual fuction section: freezing and paraffin use.

■Working Voltage: AC220V 50Hz , AC110V 60Hz

■Power Draw:50VA(KD-2258S)、300VA(KD-Ⅲ)

■Dimension: 540x400x290mm(KD-2258),420x190x410mm(KD-Ⅲ)

■Net weight:28kg(KD-2258S) 8kg(KD-Ⅲ)

Page 12: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-2258S Semi-automatic Microtome

KD-2258S Semi-automatic Microtome is

new generation to meet mordern

histopathology research. It adopt imported

guide ways,ideal devise,stable

performance,ergonomic concept,and it's new

development direction of histopathology

research.

Features:

■Ergonomic concept

■Microtome steel knife or disposable

microtome blade can be chosen

■Specimen clamp can be locked at any

position to ajust angle of sectioning

■Advanced driving systems,fuctions of

section,trimming,fast forward,backward etc

■LCD screen shows section thickness range

■Right handwheel can be locked at any position,easy and convenient

■Specimen return fuction,specimen clamp can be ajusted easily

■Blade holder can be moved horizontal or vertical,no need to touch the blade

■N Steel knife holder and E disposable blade holder

■External encloser is easy to clean,no need to unload

■Large waste tray,easy to unload

Technical Specifications:

■Section thickness range: 0.25~100μm

0. 5~2μm increment 0. 5μm

2~10μm increment 1μm

10~20μm increment 2μm

20~100μm increment 5μm

■Trimming thickness range:0~100μm

■Minimum setting value: 0. 5μm

■Object feed: 26mm

■Vertical stroke: 52mm

■Maximum specimen size: 60 x 50mm

■Precision error: ±5%

■Working Voltage: AC220V 50Hz / AC110V 60Hz

■Power draw:50VA

■Dimension: 540x400x290mm

■Net weight:28kg

Page 13: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-2258-Ⅲ Rotary Microtome+Fast Freezing machine

This model combime KD-2258

Rotary Microtome and KD-III fast

freezing machine.KD-III adopt

high-power semi-conductor freezing

system and advanced nano

meterial.LCD shows setting and

current temperature,self-temperature

control,self-protection systems an

defrost fuction etc.

This model adopt streamline

design,advanced fuction,stable

performance,user-friendly.Specimen

feed drive is controled by intelligent

control system..Precise electrical

mechanical design,Ergonomic

concept.

Technical Specifications:

■ Section thickness range:0.5~60μm

■ Setting value:0.5~2μm increment 0.5μ

2~10μm increment 1μm

10~20μm increment 2μm

20~60μm increment 5μm

■ Trimming thickness range: 1~60μm

■ Precision error: ±5%

■ Minimum setting value: 0.5μm

■ Object feed: 28mm

■ Vertical stroke: 60mm

■ Maximum specimen size: 60 x 50mm

■ Specimen return range: 0~28mm

■Pre-setting temperature range: ambient~-55℃

■ Maximum temperature range for Cryo-plate ≥60℃

■Maximum temperature range for Cryo-probe: ≥50℃

■ Maximum size of Cryo-pate: 45 x 40mm

■ Pre-setting and current temperature shown in LCD

■ Best section angle between Cryo-proble and section blade is 60 degrees

■Temperature of defrost display,pre-setting temperature can be stored itself afte working

■Temperature of section can be reached after freezing within 4~7 minutes

■Dual fuction section: freezing and paraffin use

■Working Voltage:AC220V 50Hz , AC110V 60Hz

■ Power draw:300VA

■ Dimension:500x460x300mm(KD-2258),420x190x410mm(KD-Ⅲ)

■ Net weight:23.3kg(KD-2258), 8kg(KD-Ⅲ)

Page 14: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-2258 Manual Microtome

This model is specially developed

for modern histopatholgy research.

It adopt imported guide ways,ideal

devise,stable performance,ergonomic

concept,and it's new development

direction of histopathology research.

Features:

■ Ergonomical conception of

devise,no feeling of tire for routine

operation

■Good section result whether by

use of Standard Steel Knife or

Disposable Blade

■ Specimen clamp positioned at

8 X/Y precision orientation system

■ Handweel system allow the handwheel locked at any position

■ Specimen block can be changed easily and conveniently

■ Blade holder can be moved horizontal or vertical,no need to touch the blade

■ N Steel knife holder and E disposable blade holder

■ External encloser is easy to clean,no need to unload

■ Large waste tray,easy to unload

Technical Specifications:

■ Section thickness range:0.5~60μm

■ Setting value: 0.5~2μm increment 0.5μ

2~10μm increment 1μm

10~20μm increment 2μm

20~60μm increment 5μm

■ Trimming thickness range: 1~60μm

■ Minumum Setting value:0.5μm

■ Precision Error:±5%

■ Maximum Specimen Size:60x50mm

■ Object Feed: 28,Vertical Stroke: 60mm

■ Speciment return range: 0~28mm

■ Dimension: 500mx460mm x300mm

■ Net Weight: 23.3kg

Page 15: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-2508-Ⅲ Rotary Microtome+Fast Freezing machine

This model combime KD-2508 Rotary Microtome and KD-III fast freezing machine.KD-III adopt

high-power semi-conductor freezing system and advanced nano meterial.LCD shows setting and current

temperature,self-temperature control,self-protection systems an defrost fuction etc.

This model adopt streamline design,advanced fuction,stable performance,user-friendly.Specimen feed

drive is controled by intelligent control system..Precise electrical mechanical design,Ergonomic concept.

■ Section thickness range:1~25μm ,1~35μm

■ Minimum setting value: 1μm

■ Precision error: ±5%

■ Maximum specimen size: 60 x 40mm

■Dural purpose of blade holder,high profile blade or low profile blade can be changed

■ Steel knife holder or disposable blade holder can be changed

■ Pre-setting temperature range: ambient~-55℃

■ Maximum temperature range for Cryo-plate ≥60℃

■ Maximum temperature range for Cryo-probe: ≥50℃

■ Maximum size of Cryo-pate: 45 x 40mm

■ Pre-setting and current temperature shown in LCD

■Best section angle between Cryo-proble and section blade is 60 degrees

■ Temperature of defrost display,pre-setting temperature can be stored itself afte working

■Temperature of section can be reached after freezing within 4~7 minutes

■ Dual fuction section: freezing and paraffin use.

■ Working voltage:AC200V 50Hz、AC110V 60Hz

■ Power draw:300VA

■ Dimension:450x320x320mm (KD-2508), 420x190x410mm (KD-Ⅲ)

■ Net weight:19kg(KD-2508) 8kg(KD-Ⅲ)

Page 16: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-2508 Manual Microtome

This model Microtome adopt advanced,imported guide ways,ideal devise,high precision,stable

performance,easy to operation.It is good choice for histology or cytology research.

Technical specifications:

■Section thickness range: 1~25,1~35

■Minumum setting value: 1um

■Precision error: ±5%

■Maximum specimen size: 60 x 40mm

■Dural purpose of blade holder,high profile blade or low profile blade can be changed

■Steel knife holder or disposable blade holder can be changed

■Dimension: 450x320x320mm

■Net weight: 19kg

Page 17: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-1508R-Ⅲ Rotary Microtome+Fast Freezing machine

This model combime KD-1508R Rotary Microtome and KD-III fast freezing machine.KD-III adopt

high-power semi-conductor freezing system and advanced nano meterial.LCD shows setting and current

temperature,self-temperature control,self-protection systems an defrost fuction etc.

This model adopt streamline design,advanced fuction,stable performance,user-friendly.Specimen feed

drive is controled by intelligent control system..Precise electrical mechanical design,Ergonomic concept.

Technical Specifications:

■ Section thickness range: 1~35μm

■ Minimum setting value: 1μm

■ Precision error: ±5%

■ Maximum specimen size: 60 x 40

■Dural purpose of blade holder,high profile blade or low profile blade can be changed

■ Steel knife holder or disposable blade holder can be changed

■ Pre-setting temperature range: ambient~-55℃

■ Maximum temperature range for Cryo-plate ≥60℃

■ Maximum temperature range for Cryo-probe: ≥50℃

■ Maximum size of Cryo-pate: 45 x 40mm

■ Pre-setting and current temperature shown in LCD

■Best section angle between Cryo-proble and section blade is 60 degrees

■Temperature of defrost display,pre-setting temperature can be stored itself afte working

■Temperature of section can be reached after freezing within 4~7 minutes

■ Dual fuction section: freezing and paraffin use

■ Working voltage:AC200V 50Hz、AC110V 60Hz

■ Power draw:300VA

■ Dimension:470x320x320mm (KD-1508), 420x190x410mm (KD-Ⅲ)

■ Net weight:22.5kg(KD-2508) 8kg(KD-Ⅲ)

Page 18: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-1508R Rotary Microtome

This model microtome is developed based on KD-1508A,1508model.It adopt advanced precise guide

rail technics and high-strength alloy steel material.It specially used to cut

fiber,plastic,rubber,bone,plant,feather and other hard specimen block.

Technical Specifications:

■Section thickness setting range: 1~35um

■Maximum specimen size: 60 x40mm

■Minimum setting value: 1um

■Precision error: ±5%

■Dimension: 470x320x320mm

■Net weight: 22.5kg

Page 19: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-1508A-Ⅲ Rotary Microtome+Fast Freezing machine

This model combime KD-1508A Rotary Microtome and KD-III fast freezing machine.KD-III adopt

high-power semi-conductor freezing system and advanced nano meterial.LCD shows setting and current

temperature,self-temperature control,self-protection systems an defrost fuction etc.

This model adopt streamline design,advanced fuction,stable performance,user-friendly.Specimen feed

drive is controled by intelligent control system..Precise electrical mechanical design,Ergonomic concept.

Technical Specifications:

■ Section thickness range:1~35μm, >35μm section range can be adjusted freely

■ Minimum setting value: 1μm

■ Precision error: ±5%

■ Maximum specimen size: 50 x 40mm

■ Pre-setting temperature range: ambient~-55℃

■ Maximum temperature range for Cryo-plate ≥60℃

■ Maximum temperature range for Cryo-probe: ≥50℃

■ Maximum size of Cryo-pate: 45 x 40mm

■ Pre-setting and current temperature shown in LCD

■Best section angle between Cryo-proble and section blade is 60 degrees

■ Temperature of defrost display,pre-setting temperature can be stored itself afte working

■Temperature of section can be reached after freezing within 4~7 minutes

■ Dual fuction section: freezing and paraffin use

■ Working voltage:AC220V 50Hz、AC110V 60Hz

■ Power draw:300VA

■ Dimension:470x320x320mm(KD-1508A),420x190x410mm(KD-Ⅲ)

■ Net weight:22.5kg(KD-1508A) 8kg(KD-Ⅲ)

Page 20: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-1508A Manual Microtome

KD-1508A Rotary microtome adopt advanced guide ways,high-strength alloy steel materials,ideal

devise.It's very suitable for rearch in cutting fiber,plastic,bone,plant,hair and other hard specimens.

Technical specifications:

■ Section thickness range 1~35um, >35μm section range can be adjusted freely

■ Maximum specimen size: 50 x 40mm

■ Minimum setting value: 1 um

■ Precision error: ±5%

■ Dimension: 470x320x320mm

■ Net weight: 22.5kg

Page 21: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-202A-Ⅲ Rotary Microtome+Fast Freezing machine

This model combime KD-202A Rotary Microtome and KD-III fast freezing machine.KD-III adopt

high-power semi-conductor freezing system and advanced nano meterial.LCD shows setting and current

temperature,self-temperature control,self-protection systems an defrost fuction etc.

This model adopt streamline design,advanced fuction,stable performance,user-friendly.Specimen feed

drive is controled by intelligent control system..Precise electrical mechanical design,Ergonomic concept.

Technical Specifications:

■ Section thickness range:1~25μm, >25μm section range can be adjusted freely

■ Minimum setting value: 1μm

■ Precision error: ±10%

■ Easy to operate,clean external encloser

■ Display of numbers of specimen section,emergency-stop system

■ Maximum specimen size: 40 x 30mm

■ Pre-setting temperature range: ambient~-55℃

■ Maximum temperature range for Cryo-plate ≥60℃

■ Maximum temperature range for Cryo-probe: ≥50℃

■ Maximum size of Cryo-pate: 45 x 40mm

■ Pre-setting and current temperature shown in LCD

■Best section angle between Cryo-proble and section blade is 60 degrees

■ Temperature of defrost display,pre-setting temperature can be stored itself afte working

■Temperature of section can be reached after freezing within 4~7 minutes

■ Dual fuction section: freezing and paraffin use.

■ Working voltage:AC220V 50Hz、AC110V 60Hz

■ Power draw:300VA

■ Dimension:380x340x270mm(KD-202A)

420x190x410mm(KD-Ⅲ)

■ Net weight:21.5kg(KD-202A) 8kg(KD-Ⅲ)

Page 22: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-202A Manual Microtome

This model is simple rotary microtome,handwheel locked at top of it,paraffin block can be changed

easily and safe.LCD shows numbers of sectioning,emergency stop systems.Clean encloser,blade holder can

be moved horizontal or vertical.

Technical specifications:

■Section thickness range: 1~25 um , >25μm

■Minimum setting value: 1um

■Maximum specimen size: 40 x 30mm

■Precision error: ±10%

■Dimension: 380x340x270mm

■Net weight: 21.5kg

Page 23: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-202-Ⅲ Rotary Microtome+Fast Freezing machine

This model combime KD-202 Rotary Microtome and KD-III fast freezing machine.KD-III adopt

high-power semi-conductor freezing system and advanced nano meterial.LCD shows setting and current

temperature,self-temperature control,self-protection systems an defrost fuction etc.

This model adopt streamline design,advanced fuction,stable performance,user-friendly.Specimen feed

drive is controled by intelligent control system..Precise electrical mechanical design,Ergonomic concept.

Technical Specifications:

■ Section thickness range: 1~25μm

■ Minimum setting value: 1μm

■ Precision error: ±10%

■ Maximum specimen size: 35 x 25mm

■ Pre-setting temperature range: ambient~-55℃

■ Maximum temperature range for Cryo-plate ≥60℃

■ Maximum temperature range for Cryo-probe: ≥50℃

■ Maximum size of Cryo-pate: 45 x 40mm

■ Pre-setting and current temperature shown in LCD

■Best section angle between Cryo-proble and section blade is 60 degrees

■ Temperature of defrost display,pre-setting temperature can be stored itself afte working

■Temperature of section can be reached after freezing within 4~7 minutes

■ Dual fuction section: freezing and paraffin use.

■ Working voltage:AC220V 50Hz、AC110V 60Hz

■ Power draw:200VA

■ Dimension:290x300x220mm(KD-202)

420x190x410mm(KD-Ⅲ)

■ Net weight:21kg(KD-202) 8kg(KD-Ⅲ)

Page 24: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-202 Manual Microtome

This model is very simple,typical rotary microtome,it adopt crank driving system,ratchat feeding

mechanics and continuous sectioning fuction etc.

Technical specifications:

■Section thickness range: 1~25 um

■Minimum setting value: 1um

■Maximum specimen size: 35 x 25mm

■Precision error: ±10%

■Dimension: 290x300x220mm

■Net weight: 21kg

Page 25: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-400 Vibrating Microtome

This model is specially developed according to market demand,it introduce advanced technics from

overseas.It is widely used in biological,teaching,scientific institute research etc.It is used to cut fresh or

specific specimen from animals or plants,specimen can be cut immediately in no case of embedding,cooling

progress.Therefore,specimen doesn't broke at all,and cell keep very good and active.It provide good

condition for immunocytochemistry research and spinal&celebrum disorder's neurobiology. This model is

very good choice for fiields in electro microscope,dissect, cyemology,physiology,biology,scientific research.

According to finding result from related college or scientific institue,10um is minimum section setting

range when cutting brain or spinal cord specimen.And,30um when cutting fresh brain,heart,kidney specimen.

Technical Specifications:

■Speed of Specimen Sectioning: 0-1.3mm/s(adjustable)

■ Vibrating range: 0~1mm

■ Specimen table lifting range: 9mm

■ Section thickness setting range: >10um

■ Minimum setting value: 1um

■ Angle of blade: 15degrees

■Working Voltage:AC220V 50Hz

AC110V 60Hz

■ Power Draw:200VA

■ Dimension:400x220x300mm

■ Net Weight:12kg

Page 26: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-BMR Paraffin Dispenser

Features:

■The full automatic procedure control&new heating element gives feature of quick heating&energy

saving

■The temperature survey integration block from American DALLAS Corporation has been used to

make it precise in temperature survey and credible in performance

■It possesses the function of memorization to keep the set temperature automatically after startup

■ The LED shows heating state

Technical Specifications:

■ Range of temperature:ambient~100℃

■ Precision:±1%

■ Voltage:AC220V 50HZ

AC110V 60 HZ

■ Power : 1200VA

■ Capacity: 10000ml

■ Overall dimension:350x450x510mm

■ Net Weight:17kg

Page 27: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-BM & BL Tissue Embedding & Cooling System

Features:

■ The full

automatic procedure

control can make it

possible for presetting

the start time of any

weekday in one week

■ The odd

controlling-microprocess

or from American

ATMEL Corporation has

been used to make it

easy to control

temperature and the

shining tube has been

used to display the

temperature so that we

can clearly know the

working state

■ Five heating zones, paraffin tank、dispensor、 left tank 、 right tank 、working area , can work

independent without interference

■ The temperature survey integration block from American DALLAS Corporation has been used to

make it precise in temperature survey and credible in performance. It is safe by employing the dual

overheat-avoidance devices to protect the heating system

■ It possesses the function of memorization to keep the set temperature automatically after startup

■ Tissue embedding system and cooling plate can use seperately or combined at your option

■ Heating working area and forcep holder is convenient to embed the tissue

■ Large working aera is convenient to clean paraffin

Technical specifications:

■The advanced heating theory to keep the paraffin on ideal temperature 70℃ to avoid paraffin shrink

and affect the tissue specimen

■Range for setting temperature of the forceps holder:55~70℃

■Range for setting temperature of the paraffin tank:55~70℃

■Range for setting temperature of the reservior:55~70℃

■Range for setting temperature of the working area:55~70℃

■Range for setting temperature of the dispensor:55~70℃

■Temperature control precesion:±1%

■Way of paraffin flow:soft touch manual switch、foot switch

■Time presetting: presetting the start time of any weekday during one week

■Working temperature of the Cooling plate : room temperature~-20℃

■Norminal voltage :AC220V 50Hz ,AC110V 60Hz

■Power draw:1000VA

■Demension:550x500x360mm(KD-BM),345x500x360mm(KD-BL)

■Weight:28kg(KD-BM) ,25kg(KD-BL)

Page 28: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-BM Tissue Embedding Center

Features:

■The full automatic procedure

control can make it possible for

presetting the start time of any

weekday in one week

■ The odd

controlling-microprocessor from

American ATMEL Corporation has

been used to make it easy to control

temperature and the shining tube

has been used to display the

temperature so that we can clearly

know the working state

■Five heating zones, paraffin

tank、dispensor、 left tank 、 right

tank 、working area , can work independent without interference

■The temperature survey integration block from American DALLAS Corporation has been used to

make it precise in temperature survey and credible in performance. It is safe by employing the dual

overheat-avoidance devices to protect the heating system

■It possesses the function of memorization to keep the set temperature automatically after startup

■Tissue embedding system and cooling plate can use seperately or combined at your option

■Heating working area and forcep holder is convenient to embed the tissue

■Large working aera is convenient to clean paraffin

Technical specifications:

■The advanced heating theory to keep the paraffin on ideal temperature 70℃ to avoid paraffin shrink

and affect the tissue specimen

■ Range for setting temperature of the forceps holder:55~70℃

■ Range for setting temperature of the paraffin tank:55~70℃

■ Range for setting temperature of the reservior:55~70℃

■ Range for setting temperature of the working area:55~70℃

■ Range for setting temperature of the dispensor:55~70℃

■ Temperature control precesion:±1%

■ Way of paraffin flow:soft touch manual switch、foot switch

■Time presetting: presetting the start time of any weekday during one week

■ Norminal voltage :AC220V 50Hz,AC110V 60Hz

■ Power draw:1000VA

■ Demension:550x500x360mm(KD-BM)

■ Weight:28kg(KD-BM)

Page 29: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-BMII & BL Tissue Embedding & Cooling System

Features:

■ The full automatic

procedure control can make

it possible for presetting the

start time of any weekday in

one week

■ The odd

controlling-microprocessor

from American ATMEL

Corporation has been used

to make it easy to control

temperature and the shining

tube has been used to

display the temperature so

that we can clearly know the

working state

■ Five heating zones, paraffin tank、dispensor、 left tank 、 right tank 、working area , can work

independent without interference

■The temperature survey integration block from American DALLAS Corporation has been used to

make it precise in temperature survey and credible in performance. It is safe by employing the dual

overheat-avoidance devices to protect the heating system

■ It possesses the function of memorization to keep the set temperature automatically after startup

■ Tissue embedding system and cooling plate can use seperately or combined at your option

■Big paraffin tank ensure dealing with all the tissue in one time

■ Low illumating system , safe & stable

■ Heating working area and forcep holder is convenient to embed the tissue

■ Large working aera is convenient to clean paraffin

Technical specifications:

■The advanced heating theory to keep the paraffin on ideal temperature 70℃ to avoid paraffin shrink

and affect the tissue specimen

■Range for setting temperature of the forceps holder:55~70℃

■Range for setting temperature of the paraffin tank:55~70℃

■Range for setting temperature of the reservior:55~70℃

■Range for setting temperature of the working area:55~70℃

■Range for setting temperature of the dispensor:55~70℃

■ Temperature control precesion:±1%

■Way of paraffin flow:soft touch manual switch、foot switch

■Time presetting: presetting the start time of any weekday during one week

■Working temperature of the Cooling plate : room temperature~-20℃

■Norminal voltage :AC220V 50Hz ,AC110V 60Hz

■Power draw:1000VA

■Demension:550x550x360mm(KD-BMⅡ), 345x500x360mm(KD-BL)

■Weight:30kg(KD-BMⅡ) ,25kg(KD-BL)

Page 30: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-BMⅡ Tissue Embedding Center

Features:

■ The full automatic

procedure control can make it

possible for presetting the

start time of any weekday in

one week

■ The odd

controlling-microprocessor

from American ATMEL

Corporation has been used to

make it easy to control

temperature and the shining

tube has been used to display

the temperature so that we

can clearly know the working

state

■ Five heating zones,

paraffin tank、dispensor、 left tank 、 right tank 、working area , can work independent without interference

■ The temperature survey integration block from American DALLAS Corporation has been used to

make it precise in temperature survey and credible in performance. It is safe by employing the dual

overheat-avoidance devices to protect the heating system

■It possesses the function of memorization to keep the set temperature automatically after startup

■ Tissue embedding system and cooling plate can use seperately or combined at your option

■ Big paraffin tank ensure dealing with all the tissue in one time

■ Low illumating system , safe & stable

■ Heating working area and forcep holder is convenient to embed the tissue

■ Large working aera is convenient to clean paraffin

Technical specifications:

■The advanced heating theory to keep the paraffin on ideal temperature 70℃ to avoid paraffin shrink

and affect the tissue specimen

■ Range for setting temperature of the forceps holder:55~70℃

■ Range for setting temperature of the paraffin tank:55~70℃

■ Range for setting temperature of the reservior:55~70℃

■ Range for setting temperature of the working area:55~70℃

■ Range for setting temperature of the dispensor:55~70℃

■ Temperature control precesion:±1%

■ Way of paraffin flow:soft touch manual switch、foot switch

■ Time presetting: presetting the start time of any weekday during one week

■ Norminal voltage :AC220V 50Hz,AC110V 60Hz

■ Power draw:1000VA

■ Demension:550x550x360mm(KD-BMⅡ)

■ Weight:30kg(KD-BMⅡ)

Page 31: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-BMIII、BLIII、BC Tissue Embedding & Cooling System

Features:

■ The full automatic procedure control can make it possible for presetting the start time of any

weekday in one week

■ The new rubber silcon calorific material has been used to make it heat up quickly and heated equally,

and energy-saving

■ The temperature survey integration block from American DALLAS Corporation has been used to

make it precise in temperature survey and credible in performance. LCD displays working state with icon

■ Five heating zones, paraffin tank、dispensor、 left tank 、 right tank 、working area , can work

independent without interference with five temperature control line , servel overheat-avoidance devices to

protect the heating system

■ It possesses the function of memorization to keep the set temperature automatically after startup

■ Tissue embedding system, cooling plate and conservation table can use seperately or combined at

your option

■ Heating working area and forcep holder is convenient to embed the tissue

■ New frequency conversion compressor used in cooling plate to adjust the temperature freely to

adjust between +50℃~-35℃

■ The cooling spot on embeding center can refrigerate the tissue specimen immdiately

■ Large voulmn paraffin tank ensure the capacity to finish work one time

■ Low voltage illuminating system for safty operation , two startup model : manua and foot switch

■ Large working aera is convenient to clean paraffin

■ Precise in time display, and it is simple for timing

Technical specifications:

■ Adopted advanced heating theory

■ Volume of paraffin tank:5 liters

■ Range of temperature-control of forcep holder :ambient~99℃

■ Range of temperature in paraffin tank :ambient~99℃

■ Range of temperature in storing box: ambient~99℃

■ Range of temperature at workstation: ambient~99℃

■ Range of tempreature of heating system: ambient~99℃

■ Tolerance:±1%

■ Mode of wax-flow:automatic soft-touching manual switch 、foot switch

■ Time presetting: presetting the start time of any weekday during one week

■ Temperature of cooling -plate:ambient ≤-20℃,protection function of time delay

■ Dimension of cooling plate:330 x 322mm

■ Niminal Voltage:AC220V 50Hz AC110V 60Hz

■ Power draw: 800VA(KD-BMⅢ),100VA(KD-BLⅢ),150VA(KD-BC)

■ Dimension: 650x580x450mm(KD-BMⅢ),652x380x425mm(KD-BLⅢ) 602x380x425mm(KD-BC)

■ Weight: 29kg(KD-BMⅢ) 20kg(KD-BLⅢ) 12kg(KD-BC)

Page 32: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-BMIII、BLIII Tissue Embedding & Cooling System

Features:

■ The full automatic

procedure control can make it

possible for presetting the start

time of any weekday in one

week

■ The new rubber silcon

calorific material has been used

to make it heat up quickly and

heated equally, and

energy-saving

■ The temperature survey

integration block from American

DALLAS Corporation has been

used to make it precise in

temperature survey and credible

in performance. LCD displays

working state with icon

■ Five heating zones, paraffin tank、dispensor、 left tank 、 right tank 、working area , can work

independent without interference with five temperature control line , servel overheat-avoidance devices to

protect the heating system

■It possesses the function of memorization to keep the set temperature automatically after startup

■Tissue embedding system, cooling plate and conservation table can use seperately or combined at

your option

■ Heating working area and forcep holder is convenient to embed the tissue

■New frequency conversion compressor used in cooling plate to adjust the temperature freely to adjust

between +50℃~-35℃

■The cooling spot on embeding center can refrigerate the tissue specimen immdiately

■ Large voulmn paraffin tank ensure the capacity to finish work one time

■Low voltage illuminating system for safty operation , two startup model : manua and foot switch

■ Large working aera is convenient to clean paraffin

■ Precise in time display, and it is simple for timing

Technical specifications:

■ Adopted advanced heating theory

■ Volume of paraffin tank:5 liters

■ Range of temperature-control of forcep holder :ambient~99℃

■ Range of temperature in paraffin tank :ambient~99℃

■ Range of temperature in storing box: ambient~99℃

■ Range of temperature at workstation: ambient~99℃

■ Range of tempreature of heating system: ambient~99℃

■ Presion error:±1%

■ Mode of wax-flow:automatic soft-touching manual switch 、foot switch

■ Time presetting: presetting the start time of any weekday during one week

■ Temperature of cooling -plate:ambient ≤-20℃,protection function of time delay

■ Dimension of cooling plate:330 x 322mm

■ Niminal Voltage: AC220V 50Hz AC110V 60Hz

■ Power draw: 800VA(KD-BMⅢ),100VA(KD-BLⅢ)

■ Dimension: 650x580 x450mm(KD-BMⅢ),652x380 x425mm(KD-BLⅢ)

■ Weight: 29kg(KD-BMⅢ) 20kg(KD-BLⅢ)

Page 33: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-BMIII Tissue Embedding Center

Features:

■ The full automatic

procedure control can make

it possible for presetting

the start time of any

weekday in one week

■ The new rubber

silcon calorific material has

been used to make it heat

up quickly and heated

equally, and energy-saving

■ The temperature

survey integration block

from American DALLAS

Corporation has been used

to make it precise in

temperature survey and

credible in performance.

LCD displays working

state with icon

■Five heating zones,

paraffin tank、dispensor、 left tank 、 right tank 、working area , can work independent without interference

with five temperature control line , servel overheat-avoidance devices to protect the heating system

■ It possesses the function of memorization to keep the set temperature automatically after startup

■ Tissue embedding system, cooling plate and conservation table can use seperately or combined at

your option

■ Heating working area and forcep holder is convenient to embed the tissue

■ New frequency conversion compressor used in cooling plate to adjust the temperature freely to

adjust between +50℃~-35℃

■ The cooling spot on embeding center can refrigerate the tissue specimen immdiately

■ Large voulmn paraffin tank ensure the capacity to finish work one time

■Low voltage illuminating system for safty operation , two startup model : manua and foot switch

■ Large working aera is convenient to clean paraffin

■ Precise in time display, and it is simple for timing

Technical specifications:

■ Adopted advanced heating theory

■ Volume of paraffin tank:5 liters

■ Range of temperature-control of forcep holder :ambient~99℃

■ Range of temperature in paraffin tank :ambient~99℃

■ Range of temperature in storing box: ambient~99℃

■ Range of temperature at workstation: ambient~99℃

■ Range of tempreature of heating system: ambient~99℃

■ Presion error:±1%

■ Mode of wax-flow:automatic soft-touching manual switch 、foot switch

■ Time presetting: presetting the start time of any weekday during one week

■Temperature of cooling -plate:ambient ≤-20℃,protection function of time delay

■ Dimension of cooling plate:330 x 322mm

■ Niminal Voltage: AC220V 50Hz

AC110V 60Hz

■ Power draw: 800VA(KD-BMⅢ)

■ Dimension: 650x580 x450mm(KD-BMⅢ)

■ Weight: 29kg(KD-BMⅢ)

Page 34: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-BLⅢ Cryo-Plate

KD-BLIII Cryo-plate adopted with new-type inverter

compressor ,which makes tissue paraffin cooled quickly,

teflon plating ensure easy cleaning,cooling temperature can

be adjusted freely,temperature is setted properly to avoid

tissue wax from not cooling enough or frost splitting,KD-BL

Ⅲcryo-plate can be use seperately.

Technical specifications:

■ Setting temperature:+50℃~-35℃

■ Protection requirement of time delay

■ Area of cryo-plate:330x322mm

■ Voltage: AC220V 50Hz

AC110V 50Hz

■ Power:100VA

■ Dimension:652x380x425mm

■ Weight:20kg

Page 35: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-BC Tissue Conserving Table

KD-BC conserve any-type tissue embedding

cassette,embedding box,embedding mould and tissue

which was processed;high-capacity,easy for storage,this

instrument can be operated seperately,also used for tissue

speading.

Technical specifications:

■ Setting temperature:ambient ~90℃

■ Protection requirement of time delay

■ Volume:4.5 liter

■ Voltage:AC 220V 50 Hz

AC 110V 50Hz

■ Power:150VA

■ Dimension:602x380x425mm

■ Weight :12kg

Page 36: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-T Tissue Flotation Workstation

Features:

■ Adopted with ATMEL

microprocessor technique,

New heating material

■ The new design is

unique and compact combining

with wather bath & hot plate .

It is easy on operation , stable

on function , light&small

■ General used for

pathological research in

hospital, medical college,

sanitation division etc

Technical specifications:

■ Range of spreading temperature of water: ambient to 90℃ (constant adjusting)

■ Range of roasting temperature: ambient to 90℃ (constant adjusting)

■Self memory of presetting temperature after running instrument

■ Allowance ambient temperature: 0 - 40℃

■ Working voltage: 220 V /50 Hz

■ Power: < 500 W

■ Dimensions overall: 550 x 400 x 120 mm

■ Weight: 13 kg

Page 37: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate
Page 38: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-TH1 Tissue Flotation Workstation

Features:

■ Broad LCD, indicating the heating state with icon

to show clearly , easy operation

■ The new PTC calorific material has been used to

make it heat up quickly and heated equally, small in the

heat inertia for energy-saving

■ The temperature survey integrated block from

American DALLAS Corporation has been used to make it

precise in temperature survey and credible in performance

■ Spreading bath,roasting plate is controlled

seperately,work independent without affect each other

■Automatical memorization and recover,resetting temperature stored as the intrument start to work

■ Adopted with LED tech,good light transmission,convex lens reflex easily,low voltage,low

energy-consumption

■Speading processing can't be affected by light ray/sunlight,you can find anywhere for observing

specimen

Technical specifications:

■ Temperature range of instrument :ambient~99℃

■ Precison :±1℃

■ Size of spreading bath: 259x140x65 mm(inner)

■ Size of baking plate: 110x70mm

■ Size of roasting plate: 140x70mm

■ Voltage: AC220V 50HZ

AC110V 60Hz

■ Power: 200 VA

■ Dimension: 370x440x140mm

■ Weight: 6.0kg

Page 39: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-P Water Bath

Features:

■ New heating material is

Heat conduct fast, durable,

energy-saving

■ Display presetting

temperature & current

temperature

■ Self memory of set

temperature after running

■ Corrosion-resistance of

the bath

Technical specifications:

■ Range of setting temperature: ambient to 90℃(constant adjusting)

■ Temperature tolerance: + 1℃

■ Allowance ambient temperature: 0 - 40℃

■ Working voltage: AC 220V 50Hz

AC110V 60Hz

■ Power: 200 VA

■ Dimensions overall: 340 x 340 x 120 mm

■ Weight: 6 kgs

Page 40: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-H Hot Plate

Features:

■ New heating material

is Heat conduct fast, durable,

energy-saving

■ Display presetting

temperature & current

temperature

■ Self memory of set

temperature after running

■ Corrosion-resistance

of the bath

Technical specifications:

■ Range of setting temperature: ambient to 90℃ (constant adjusting)

■ Temperature tolerance: + 1℃

■ Allowance ambient temperature: 0 - 40℃

■ Working voltage: AC 220V 50Hz

AC110V 60Hz

■ Power: 200 VA

■ Dimension: 340 x 340 x 120 mm

■ Weight: 6 kg

Page 41: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-XF Histo-Trimmer

Features:

■ The full automatic procedure

control&new heating element gives feature of

quick heating&energy saving

■ The temperature survey integration

block from American DALLAS Corporation

has been used to make it precise in temperature

survey and credible in performance

■ It possesses the function of

memorization to keep the set temperature

automatically after startup

■The LED shows heating state

Technical Specifications:

■Range of temperature:ambient~90℃

■Precision :±1%

■Voltage:220V±10%50HZ

■Power : 150VA

■Size of Table:230x160mm

■Overall dimension:260(L)x185(W)x155(H)mm

■Net Weight:2kg

Page 42: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-TR Dual purpose for Tissue processor and Tissue Dyeing Processor

Features:

■ Dual purpose use for Tissue processor and Tissue Dyeing Processor,save space and reagent

■ The intelligent design can identify abnormal situation automatically

■ Bilingual LCD display , 20 sets program for tissue processor , 4 sets program for tissue dyeing

processor

■ Enviroment-friendly inner circulating air cleaning system,exaust harmful gas

■ Waterless inner heating,high precision of controlling

■ Power off self protection function makes it continue working after power off and unaffect the tissue

specimen

■ Flexible transmission is noiseless and stable . Imported parts and material ensure the good quality

Technical specifications:

■ Total stations: 16( 12 reagent station , three roasting station the 14st 15,16,one cleaning station)

■Tissue Processing time of each stations : 0s 99 hrs for station 0-24 for other tanks(2-6,11-6)

■Tissue dyeing process time : 1~14 stations:0~59min59s adjustable

■Paraffin tank temperature : ambient ~80°adjustable

■ Heating method: waterless heating

■Capacity of stations: 180mmx40 mmx100 mm

■ Specimen process: 40 pcs for tissue processor ,52 specimens for tissue dyeing processor

■ Temperature tolerance: ±1℃

■ Stir frequency : 0~6 times/min

■Power off protection : ( continue working >6 hours without outer battery), protection station: No.11

■ Working voltage: AC220V 50Hz

AC110V 60Hz

■ Power Draw : 500VA

■ Overall dimensions: 1055 x 450 x 470 mm (L x W x D)

■ Weight: 75 kg

Page 43: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-TS1A Tissue Processor(small type)

Features:

■ APS engineering

plastics,high

intensity,anti-corrosion,strea

mline design,elegant

appearance,save reagent,low

cost,economical and work

well.

■Body of this machine

is small,convenient to

operate,it adopts monolithic computer controlling technics,complete fuction,body made of organic

glass,fuction of gas exhausting,good sealability,environment-friendly and safe

■ With a capacity of at least 40 pcs tissue can be processed one time

■ Work continue in case of instant power failure or switch off once machine is working

■No-water internal heating system,high precision of temperature controlling

■Two dimension soft driving sytems,low noise,resistant to wear

■High presision photoelectric register control system,stable performance,high presion positioning

■Intelligent design,instant identification in case of problems.Memory fuction in built-in procedure.

Technical Specifications:

■Number of stations: 12(9 reagent stations,3 paraffin stations)

■ Volume of station: 700ml

■ Time setting: 0~99hours(No. 1 station)

0~24hours(other stations)

■ Temperature pre-setting range: ambient~99degrees

■ Leach liquor time: approx. 30seconds

■ Tissue protecting station: No.7 station

■ Working voltage: AC 220V , 50Hz / 110V ,60Hz

■ Power draw:500 VA

■ Heating control: heating start when basket goes into No.2 station,energy-saving

■ Dimension: 1000x450x420 mm

■ Net weight: 75kg

Page 44: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-RS1 Tissue Dyeing Processor

Features:

■ High-definition &

sensitive of touch LCD ,

effective, convenient

■ Broad screen touch

LCD 、 with man-machine

dialogue inerface , prompt

identifying can be made in

abnormal situation to make

sure each operation can be

indicated(online

help),synchronous animation

show the present working process clearly

■ Randomly setting start-up time and automatically showing finish time,make sure task is finished in

stipulated time

■ There is four sets program and can check online

■ Intellectualized infall, outfall & drainage system make sure the water is clean for every step

■ 36 immersion steps can be set , mistakbe alarm function

■ Enviroment-friendly inner circulating air cleaning system,exaust harmful gas

■ 18 stations , the 10th station is cleaning, the first station is roasting station

■ 0-30s adjustable shaking , leachate time reduce the reagent mix chance thus prolong reagent use

time and make the working surface clear

Technical specifications:

■ Total stations: 18(cleaning bath ,the 10th ;roasting bath ,the 1st )

■ Capacity of stations: 100x180x40mm

■ Specimen process: 52 pc

■ Processing time of each stations : 0s 59 min and 59 s

■ leachate time on tank shafting: 0-30S adjustable ( shaking above the station)

■Working voltage: AC220V 50Hz,AC110V 60Hz

■ Power Draw : 500VA

■ Overall dimensions: 1170 x 450 x 4070 mm (L x W x D)

■ Weight: 88kg

Page 45: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-RS Tissue Dyeing Processor

Features:

■ High-definition & sensitive

of touch LCD , effective,

convenient

■ Unique design for dyeing

process comply with ergonomic

principle , satisfying the customer

■ Flexible transmission is

noiseless and stable . Imported parts

and material ensure the good quality

■ Intellectualized infall, outfall & drainage system make sure the water is clean for every step

■ Special dyeing shelf loading with decades of specimen , covenient , safe and environmental

protection

■ Streaming water cleaning & tissue roasting function

Technical specifications:

■ Total stations: 14( 12 reagent station , cleaning bath ,the 9th ;roasting bath ,the 1st )

■ Processing time of each stations : 0s 59 min and 59 s

■ Capacity of stations: 1 L

■ specimen process: 72 pc

■ Working voltage: AC220V 50Hz

AC110V 60Hz

■ Power Draw : 500VA

■ Overall dimensions: 1130 x 460 x 400 mm (L x W x D)

■ Weight: 85 kg

Page 46: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-TS3B Automatic Tissue Processor

Features:

■ The cover is elegent with fluent line and it is spraying with APS engineering plastic which has

high-intensity,anticorrosion function and easy to clean With key parts imported, it runs steadily without

noise and comply with theory of ergonomics

■ 20sets programme 、broad screen touch LCD、with man-machine dialogue inerface , prompt

identifying can be made in abnormal situation to make sure each operation can be indicated(online help),

synchronous animation show the present working process clearly

■ Environment-friendly inner circulated air cleaning system,adsorb、remove、decompose toxic and

harmful gas in the instrument

■ Randomly setting start-up time and automatically showing finish time,make sure task is finished in

stipulated time

■ 10~60s adjustable time of dropping liquid,shaking basket,and drop liquid above cylinder once

exchange cylinder to avoid liquid mix from one bath to another,in this way, service time of reagent can be

prolonged,aviod dirty on the table

■ 0~6times /min adjustable stirring times(0 shows no-stirring),make sure all tissues immersed

thoroughly,evenly,and completed enough

■ Once power-off,protecting cylinderNo.1~7 can be set,position of protecting cylinder can be

adjusted as required

■ Self-control fan,it automatically starts up once basket goes up;as basket goes downwards,fan works

10s per min

■ Self-control illuminating lamp,it starts up in programming;touch any key to prolong to 2 min as the

instrument is running

■ Waterless inner heating,high precision of controlling

■Low energy-consuming control circuit,self-protection once power-off;display panel is still illumed

and scrolling panel indicats it's self-protecting situation as power-off,and time of running is more than 30 H

■No less than 100 tissues can be processed one time

Technical specifications:

■ Numbers of station:12 (No.9 : reagent station,No.10、11、12 are wax dispensing station)

■ Volume of each station:1500ml

■Processsing time of each station: anytime (No.1 station),0~24 H (other station)

■Range of presetting temperature: ambient~80℃

■Time of exchange station、delay、leachate:10~60s (adjustable),and leachate 、basket shaking work

above station

■Tissue Protecting station :No.1~No.7 Cylinder(adjustable)

■ Voltage:AC220V 50Hz,AC110V 60Hz

■ Power:800VA ■ Dimension:1010x550x420 mm

■ Weight:80kg

Page 47: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-TS3A Automatic Tissue Processor

Features:

■The intelligent design gives the ability to deal with abnormal situation automatically

■The imported blue LCD is

clear & stable with several control

system

■ Recirculated atmosphere

depurative system that absorbing

unhealthy volatilization gas

■ Anhydrous heating element

with high accurancy

■UPS build-up, power backup

for continous working after power off

■ With key parts imported, it runs steadily without noise and comply with theory of ergonomics

Technical specifications:

■ Numbers of tanks: 12 ( 9 liquid tanks , 3 paraffin tanks)

■ Process time: 0~99 hrs for first tank , 0~24 hrs for other tanks

■Paraffin tank temperature: ambient temperature to 99℃, double protection

■ Heating Method: Waterless inner heating

■ Capacity : 1000ml

■ Temperature tolerance : ±1℃

■ Agitate times: 2/min

■ Power off protection ( it can working >6 hrs after power off )

■ Room temperature: 0~40℃

■ Working voltage: AC220V 50Hz

AC110V 60Hz

■ Power Draw: 800 W

■ Dimension: 1000 x 420 x 450 mm

Page 48: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-TS3D1 Automatic Tissue Processor (intelligent touch screen)

Features: ■ The cover is

elegent with fluent line and it is spraying with APS engineering plastic which has high-intensity,anticorrosion function and easy to clean With key parts imported, it runs steadily without noise and comply with theory of ergonomics

■ 20sets programme 、 broad screen touch LCD、with man-machine dialogue inerface , prompt identifying can be made in abnormal situation to make sure each operation can be indicated(online help)

■ The intelligent design gives the ability to deal with unnormal situation automatically ;The synchronous animation show the present working process clearly

■ Environment-friendly inner circulated air cleaning system,adsorb、remove、decompose toxic and harmful gas in the instrument

■ Randomly setting start-up time and automatically showing finish time,make sure task is finished in stipulated time

■ 10~60s adjustable time of dropping liquid,shaking basket,and drop liquid above cylinder once exchange cylinder to avoid liquid mix from one bath to another,in this way, service time of reagent can be prolonged,aviod dirty on the table

■ 0~6times /min adjustable stirring times(0 shows no-stirring),make sure all tissues immersed thorough,evenly,and completed enough

■ Once power-off,protecting cylinderNo.1~7 can be set,position of protecting cylinder can be adjusted as required

■ Self-control fan,it automatically starts up once basket goes up;as basket goes downwards,fan works 10s per min

■ Self-control illuminating lamp,it starts up in programming;touch any key to prolong to 2 min as the instrument is running

■ Waterless inner heating,high precision of controlling ■Low energy-consuming control circuit,self-protection once power-off;display panel is still illumed

and scrolling panel indicats it's self-protecting situation as power-off,and time of running is more than 30 H ■ It can manually add the tissue during the auto running mode. Customer can check and add the tissue

conveniently during operation process ■ No less than 150 tissues can be processed one time Technical specifications: ■Numbers of station:12 (No.9 : reagent station,No.10、11、12 are wax dispensing station) ■ Volume of each station:2000ml ■ Range of presetting temperature: ambient~80℃ ■ Temperature Tolerance: ±1℃ ■ Processsing time of each station: anytime (No.1 station),0~24 H (other station) ■Time of exchange station、delay、leachate:10~60s (adjustable),and leachate 、basket shaking work

above station ■Tissue Protecting station :No.1~No.7 Cylinder(adjustable) ■ Voltage: AC220V 50Hz、AC110V 60Hz ■ Power:1000VA ■ Dimension:1135x480x490 mm ■ Weight:88kg

Page 49: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-TS3D Automatic Tissue Processor(1.8 liter)

Features:

■ The cover is elegent with fluent line and it is spraying with APS engineering plastic which has

high-intensity,anticorrosion function

and easy to clean

■ Adopted bilingual LCD

operation system , several sets control

system , man-machine dialogue

inerface ; It is environmental protection

with organic glass cover, air extract

system and good sealing property

■ The intelligent design gives the

ability to deal with unnormal situation

automatically

■ The roll and page down LCD indicates every working step

■Randomly setting start-up time and automatically showing finish time,make sure task is finished in

stipulated time

■10~60s adjustable time of dropping liquid,shaking basket,and drop liquid above cylinder once

exchange cylinder to avoid liquid mix from one bath to another,in this way, service time of reagent can be

prolonged,aviod dirty on the table

■0~6times /min adjustable stirring times(0 shows no-stirring),make sure all tissues immersed

thorough,evenly,and completed enough

■Illumilating lamp and exhaust fan are intelligent control,the lamp only works for 3 min when the

instrument is at working situation,except from reset、upward keys;fan only works once cylinder goes upwards

or making programming,its working time is 10s per min

■Environment-friendly inner circulating air cleaning system,exaust harmful gas

■Waterless inner heating,high precision of controlling

■Low energy-consuming control circuit,self-protection once power-off;display panel is still illumed

and scrolling panel indicats it's self-protecting situation as power-off

■Adopted with imported components,run smoothly,no noise,comply with theory of ergonomics

■ More than 100 tissues can be processed one time

Technical specifications:

■Numbers of cylinder:12 (no.10、11、12 are wax dispensing cylinder)

■ Volume of each cylinder:1.8litre

■Processsing time of each cylinder: anytime(No.1 cylinder) ,0~24 H (other cylinder)

■ Time of exchange cylinder、delay、leachate:10~60s (adjustable),and leachate 、basket shaking

work above cylinder

■ Voltage:AC220V 50Hz、AC110V 60Hz

■ Power:1000VA

■ Dimension:1135x480x490 mm

■ Weight:88kg

Page 50: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-TS3C Automatic double basket tissue Processor

Features:

■ Unique air-press

cover, liberality view ,

Broad LBD foodlight is

save& stable with high

efficiency , long lifetime

■ Bigger screen,

friendly and illustrational

operation panel

■ There are 3 running

model: 1 single tissue basket running model,2. double tissue basket running model, 3. crossed running model

■ Electromagnetic attaching(15Kgf) the basket and the cover

■ Individual heating element and precise temperature sensor exist in the wax baths

■ Graduation mark in each bath for easier measure

■ Battery power backup for instrument running , protecting the specimen

■ Running program : Automatic with program , ramdomly adjust the program for easier operation

■ Enclosed charcoal enhanced ventilation help control processing vapors and confused gas

Technical specifications :

■Quantity of bath : 14 (1 preparation bath, 9 reagent bath , 4 wax bath )

■ Capacity of bath : 1.8 L

■ Cover opening : electro magnetize

■Immersion time in each bath programmable from 0 minute to 99 hours and 59 minutes

■Delaying process time setting in anytime of a year

■ Station dither frequency: 1~8 times/min

■Station exchange leachate shaking frequency: 2 times

■Immersion interval from one bath to another :5 senconds

■Electricity voltage : 220V , 50Hz 110V, 60Hz

■ Working power : < 600VA

■ Instrument overall : 1220x420x500 mm

■ Weight: 98kgs

Page 51: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-TS3S Automatic double basket tissue Processor

Features:

■KD-TS3S has fluent & elegent

appearance, easy to clean since it is

coated with APS engineering plastic

with high-intensity,anticorrision

■ Flexible transmission

mechanism makes it no abrasive , no

noise . Precise positioning system

ensure the stable processing

■ Double organization operating

mode can double the processing

capability . The tissue can put on

different basket according to it size to

get better effect . If there is little tissue , it can also use one operating mode for easy operation

■ 20 sets programmed for A&B procedures,broad screen finger-touched LCD.with man-machine

dialogue,promt identifying can be made in abnormal situation to make sure each operation can be

indicated(online help)

■ LCD indicate running situation,adopted with imitated syncgraphic display to make operation process

perfect

■ Environment-friendly inner circulated air cleaning system,adsorb、remove、decompose toxic and

harmful gas in the insrument

■ Setting timing of starting up machine during 0~99hrs 59mins and automatically showing finish

time,make sue task is finished in stipulated time

■10~60s adjustable time of dropping liquid,shaking basket,and drop liquid above cylinder once

exchange cylinder to avoid liquid run from one bath to another,in this way, service time of liquid

medicine,avoid dirty on the table

■0~6times /min adjustable stirring times(0 shows no-stirring),make sure all tissues immersed

thorough,evenly,and completed enough

■ Once power-off, Protecting cylinder of tissue:No.7 for A program , No.5 for B program can be

set,position of protecting cylinder can be adjusted as required

■ Self-control fan,it automatically starts up once basket goes up;as basket goes downwards,fan works

10s per min

■Self-control illuminating lamp,it starts up in programming;touch any key to prolong to 2 min as the

instrument is running

■Waterless inner heating,high precision of controlling with triple protection ,Automatic gradient

temperature control system. Starting heating automatically when need which save energy

■Low energy-consuming control circuit,self-protection once power-off;display panel is still illumed

and scrolling panel indicats it's self-protecting situation as power-off,and time of running is more than 30 H

■ After running,randomly hand-control can be made to check or add other tissues

■ More than 200 tissues can be processed one time

Technical specificat ions :

■ Numbers of cylinder:14 (10 reagent cylinders ,No.11、12、13 14 are wax dispensing cylinder)

■ Volume of each cylinder:1500ml

■ Range of temperature: ambient~80℃

■ Precision tolerance :±1%

■ Processsing time of each cylinder: 0~99 H (No.1 No.2 cylinder),0~24 H (No.3~No.14 cylinder)

■Time of exchange cylinder、delay、leachate:10~60s (adjustable),and leachate 、basket shaking

work above cylinder

■ Times of basket shaking:0~6times /min(adjustable)

■Protecting station of tissue:No.7 for A program , No.5 for B program

■ Voltage:AC220V 50Hz、AC110V 60Hz

■ Power:550VA ■ Dimension:1250x430x490 mm

■ weight:85kg

Page 52: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-TS6A Automatic Tissue Proccessor

KD-TS6A is an advance

automatic tissue processor with micro

control.. It is used to process organic

tissue specimen,water deprived and

wax soaking into tissue specimen.It

works credibly,accurately timing and

easy to use and maintain.

The product usded for dewatering

animal and vegetable tissues on

pathological department in hospital

and scientifical research unit.

Features:

■ Adopting computer to control

whole work process,operate easily ,

work stabilization

■ It operates Flexible and

convenient with exchange jar to put tissue any stations easliy

■ It gives alarm when power off and will protecting tissue in set liquid station ,obstache protect

function

■ Adopting agitation dehydrate mode, it makes tissue mixing with solvent,paraffin fully to reach good

effect

■ The LCD display is in English,easy to use

■Time design range is wide:delay time 59hr59min Each jar working hours longest 59hr59min,Time

design least distance 1 min

■ Wax jar adopt constant temperature control system. Temperature precision high:The inner tank paint

with TEFLON for anti pollution & anit corrosion

■9pcs 1.2L transparent medicine aquarium can observe tissue process state at anytime

■ There is also obstacle alarm fuction , user can use it better and more clear

■ According to user's need to tailor standby electrical source for 4-16 hours after power off

Technical Specifications:

■ Steps of processing tissue: 12steps

■ Glass container:Quantity9 capacity 1.2L

■ Wax cup: Quantity3 capacity 1L

Temperature range45~85℃±3℃

■ Process:Each cup working hours0~59hr59min

Delay process0~59hr59min

■ Vetically reciprocative motion of tissue basket: 3 times/min

■ Tissue basket specification:Barrel tissue basket--¢ 95x80mm;Layer nacelle---¢95x80mm

■ Weight: 60kg

■ Dimension:(diameter)660x(High)550x 680(Tiptop)mm

■ Working voltage: AC220V 50Hz 、AC110V 60Hz

■ Power draw: 500W

■ Room condition : Temperature range :+5℃~40℃, humidity:﹤85%(20±5℃)

Page 53: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-TS6B Vacuum Tissue Processor

It's our key product in pathology which is also

called Tissue processer .Its used to process organic

tissue specimen,water deprived and wax soaking into

tissue specimen.It works credibly,accurately timing and

has good functions.It's easy to use and maintain.Vaccum

function can accelerate the speed of Tissue processing

The project usded for dewatering animal and

vegetable tissues is applied to pathological department

in hospital and scientifical research unit.

Features:

■ Adopting computer to control whole work

process,operate brief work stabilization

■Having exchange jar and change place control

draw perch,operate agility brief

■If lose electric give an alarm,protecting tissue in liquid,obstache protect function and so on

■Adopting agitation dehydrate mode,so tissue and solvent,paraffin meet,thereby well effect

■ Screen showing information is English ,easy to use

■Time design range wide:delay time 59hr59min;Each jar working hours longest 59hr59min;Time

design least distance 1min.Each jar can be setted vacuum seperately

■ Wax jar adopt constant temperature control system.Temperature precision high: Defend

pollution ,defend canker

■Adopting 9slices 1.2L Medicine aquarium,at any moment observe tissue change at work

■ According to user's need to tailor standby electrical source,after power cut it can work in

great,working hours can reach 416hours

Technical Specifications:

■ Steps of processing tissue: 12steps

■ Glass container: Quantity9 capacity1.2L

■ Wax container: Quantity3 capacity1.2 L

Temperature range45~85℃±3℃

■ Program: Each container working hours0~59hr59min

Delay process0~59hr59min

■ Vacuum:0.053Mpa

■ Vertivally reciprocative motion of tissue basket: 3times/min

■ Tissue basket specification: Barrel tissue basket--¢95 x 80mm

Layer nacelle--¢95 x 80mm Five layers

■ Weight: 60kg

■ Dimension: (Diameter)670x(High)550 x 680(Tiptop)mm

■ Rated voltage: AC220V 50Hz、AC110V 60Hz

■ Power draw: 500W

■ Room condition : Temperature range :+5℃~40℃, humidity:﹤85%(20±5℃)

Page 54: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-ZMD-II Automatic steel-knife grinder

Especially supply for sharpening steel

knife's edge that saving a lot of manual work of

grinding.

Technical specifications:

■ Angle of knife-edge adjustment: 20℃ -

45℃

■ Interval turnover of knife: 5s, 10s, 25s

■ Grinding time: 0 60 minutes

■ Grinding knife size: below 240 mm in length

■ Working voltage: AC220V 50Hz

AC110V 60Hz

■ Power: 40 W

■ Dimensions overall: 570 x 500 x 420 mm

■ Weight: 52 kg

Page 55: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-SK1 Tissue Ultrasound Quick Processor

Features :

■ It will alarm when working

temperature reach setting temperature

or when the working time finish

■ The heating system will

automatic cutoff and alarm when

water lower then the min standard ,

which is save for operation

■Adjustable ultrasound output

to meet the need of different liquid

and tissue amount for best effect

■The tissue process effect near same with normal tissue process with LED indicating the present

heating state , Precise temperature controlling system , clear working state showing

■ Wave I has Acetone vapor recycling function,which reduce vapor of Acetone,protect the

environment

■WaveI, Wave II have time setting function and can shut off automatically on due time

■Enclosed soft touch key is easy for operation , anti dust , anti corrosion , anti liquid

■ Self memery function

Technical specifications:

■ Water station temperature adjustment: 60℃ to 85℃

■ Ultrasound wave time setting : 1~99 mins

■ Ultrasound wave working zone:3

■ Ultrasound wave adjust frequency: continuously adjustable

■ Temperature tolerance: + 1℃

■ Working voltage: AC220V 50Hz

AC110V 60Hz

■ Power: 80VA

■ Overall dimensions: 640 x 365 x 200 mm (L x W x D)

■ Weight: 20 kg

Page 56: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-103 Biomedical slices cabine

The base use Cold-rolled steel plate SPCC1.2 from Baosteel ; the

cabinet use Cold-rolled steel plate 0.8; the drawer use Cold-rolled steel

plate 0.8 . The biomedical slices cabinet has three independent

cabinet ,each layer has six drawers with inner digital tags for easy storage .

It can contain totally around 9000 pcs slices.

Specilized slide drawer , ABS slide plate .Surface treatment : Defatted

oil, Table regulator, Zinc phosphating, passivation, Powder spraying. Slot :

The slot is do by special mold . Mark groove : Integration forming .

KD-103-1 Biomedical slices box cabinet

The base use Cold-rolled steel plate SPCC1.2 from Baosteel ; the

cabinet use Cold-rolled steel plate 0.8; the drawer use Cold-rolled steel

plate 0.8 . The biomedical slices cabinet has four independent

cabinet ,each layer can contain 96 pcs slice boxes.

Surface treatment : Defatted oil, Table regulator, Zinc phosphating,

passivation, Powder spraying. Slot : The slot is do by special mold .

Mark groove : Integration forming .

Page 57: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-102 Biomedical wax cabinet

The base use Cold-rolled steel plate SPCC1.2 from Baosteel ; the cabinet

use Cold-rolled steel plate 0.8; the drawer use Cold-rolled steel plate 0.8 . The

biomedical wax cabinet has three independent cabinet ,each layer has six

drawers . paraffin wax block can put freely with its size . It can contain totally

around 11000 purchase.

Specilized slide drawer , ABS slide plate .Surface treatment : Defatted oil,

Table regulator, Zinc phosphating, passivation, Powder spraying. Slot : The slot

is do by special mold . Mark groove : Integration forming

KD-102-1 Biomedical wax cabinet(with lock)

The base use Cold-rolled steel plate SPCC1.2 from Baosteel ; the cabinet

use Cold-rolled steel plate 0.8; the drawer use Cold-rolled steel plate 0.8 . The

biomedical wax cabinet has three independent cabinet ,each layer has six

drawers . paraffin wax block can put freely with its size . It can contain totally

around 11000 purchase.

Specilized slide drawer , ABS slide plate .Surface treatment : Defatted oil,

Table regulator, Zinc phosphating, passivation, Powder spraying. Slot : The

slot is do by special mold . Mark groove : Integration forming .

Page 58: KD-2900 Cryostat Microtome...KD-2900 Cryostat Microtome Features: Double-compressor semi automatic cryostat. Computer temperature control,manual and automated defrost fuction,separate

KD-101 Biomedical slices cabinet

The base use Cold-rolled steel plate SPCC1.2 from Baosteel ; the cabinet

use Cold-rolled steel plate 0.8; the drawer use Cold-rolled steel plate 0.8 .The

biomedical slices cabinet devide into 6 grid 12 layers with total 72 cells ,

loading more than 60000 pcs slides. Specilized slide drawer , ABS slide

plate , inner anitskip lock . Handle use ABS Chromium plating , it devides into

six grid each drawer , convenient for storage . Surface treatment : Defatted oil,

Table regulator, Zinc phosphating, passivation, Powder spraying.

Slot : The slot is do by special mold . Mark groove : Integration forming .

The unique drawer lock have declared national patent.

KD-101-1 Biomedical slides cabinet (with lock )

The base use Cold-rolled steel plate SPCC1.2 from Baosteel ; the cabinet use

Cold-rolled steel plate 0.8; the drawer use Cold-rolled steel plate 0.8 .The

biomedical slices cabinet devide into 6 grid 12 layers with total 72 cells , loading

more than 60000 pcs slides. Specilized slide drawer , ABS slide plate , inner

anitskip lock . Handle use ABS Chromium plating , it devides into six grid each

drawer , convenient for storage . Surface treatment : Defatted oil, Table regulator,

Zinc phosphating, passivation, Powder spraying.

Slot : The slot is do by special mold . Mark groove : Integration forming .

The unique drawer lock have declared national patent.