4
12/02/2008 04:02:51 RE: Konica Minolta Bizhub 420: C-2403 error... IP: Logged Message: Description C2403 (C-2403). Solution PROBABLE CAUSES: 1. When an empty toner bottle is rotated while removing it from the machine, the alignment tab goes out of home position. Then, when a new bottle is inserted, it does not rotate correctly. A modification is available. Please refer to attached Bulletin Number 5775 and follow the procedures outlined. To view the PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html . Note : To reset C-2403 after replacing the toner bottle, perform the following: a. Power OFF the main switch (SW2, inside front door). b. Slide the toner bottle cradle and remove spent toner bottle. c. Prepare new toner bottle per instructions and place toner bottle in the cradle (line up the two notches at the rear so the cartridge is laying level in the cradle). d. Turn bottle completely around and line up the arrow at the 12 o'clock position clockwise or counterclockwise and push cradle in and lock toner door. e. The power should be re-enabled to ON while holding the Utility key; the Konica Minolta blue screen within 6 minutes, then the white screen with Trouble

KM 420 C 2403

Embed Size (px)

DESCRIPTION

service info

Citation preview

Page 1: KM 420 C 2403

12/02/2008

04:02:51

RE: Konica Minolta Bizhub 420: C-2403 error...

IP: Logged

Message:

Description

C2403 (C-2403).

Solution

PROBABLE CAUSES:

1. When an empty toner bottle is rotated while removing it from the machine, the alignment tab goes out of home position. Then, when a new bottle is

inserted, it does not rotate correctly.

A modification is available. Please refer to attached Bulletin Number 5775 and follow the procedures outlined. To view the PDF, Adobe Reader® must be

installed. Adobe Reader® can be downloaded for free from the Adobe® web site at: http://www.adobe.com/products/acrobat/readstep2.html .

Note : To reset C-2403 after replacing the toner bottle, perform the following:

a. Power OFF the main switch (SW2, inside front door).

b. Slide the toner bottle cradle and remove spent toner bottle.

c. Prepare new toner bottle per instructions and place toner bottle in the cradle (line up the two notches at the rear so the cartridge is laying level in the

cradle).

d. Turn bottle completely around and line up the arrow at the 12 o'clock position clockwise or counterclockwise and push cradle in and lock toner door.

e. The power should be re-enabled to ON while holding the Utility key; the Konica Minolta blue screen within 6 minutes, then the white screen with Trouble

Reset. Touch and OK will appear. f. Power OFF/ON and should go to Ready. This procedure may have to be redone several times.

2. Toner bottle is not turning.

Ensure that the toner bottle does not have any manufacturing defects. Also ensure that the pressure spring inside the pressure assembly (p/n 26TA-3332) is

Page 2: KM 420 C 2403

applying sufficient pressure when locked into place.

3. Excessive pressure from the Toner Bottle Door.

Remove the pressure springs (Toner Supply Unit (TSU), item #7 - see attached) located in toner door.

4. The toner bottle position sensor (PS28) may have shifted when the drive section on the back of the machine was removed or installed. As a result, PS28

cannot detect rotation of the toner bottle.

Install a new mounting plate (p/n 50GA33161E) and stopper seal (p/n 447042481) for PS28. These parts prevent PS28 from becoming dislodged. Complete

details are in attached Bulletin Number 6078.

5. Contact between parts around the bottle guide section.

Please install the Toner supply auxiliary cover countermeasure as explained in the attached Parts Modification Notice.

6. If toner bottle is not installed correctly and the customer forces it then it may cause tearing of the drive tabs on the toner bottle. This will cause the bottle

not find the home position generating this error.

Please ensure that the toner bottle is inserted correctly. Refer to Bulletin 5471 for details on a modification to the toner guide assembly.

7. Even though the correct procedure was used per Bulletin Number 5471 , there still may be burrson theflange tips at neck of the toner bottle

7. Even though the correct procedure was used per Bulletin Number 5471 , there still may be burrson theflange tips at neck of the toner bottle.Also,PS4

and PS28 may not be sensing properly.

Verify the correct operation of PS4 and PS28. Check for burrson theflange tips at neck of the toner bottle. Use Scotch-Brite™ to remove the burrs on the

toner bottle.

Note : The service documentation does not include a procedure for checking PS4 (Toner Bottle Sensor) and the PS28 (Toner Bottle Position Sensor). To

check:

a. Enter the State Confirm mode=>'Service Mode screen'; press [State Confirmation].

b.'State Confirmation screen'; press [Sensor check].

c. 'Sensor Check screen'; press [Check Code] and, when entering the sensor check code in 3-digit format through the copy count setting button, a state

(ON/OFF) or value is displayed in the Result area.

d. For the multi-mode, press [Multi Code] and enter a three-digit multi-code through the copy count setting key. When conducting the sensor check of other

Page 3: KM 420 C 2403

signal sources, repeat stepscand d.

IMPORTANT : Code 57, multi-mode 2, which is not listed in the bizhub 420/500 Service Manual, is used to monitor the output signals ofPS4 (Toner Bottle

Sensor), and multi-mode 3 for monitoring the output signal ofPS28 (Toner Bottle Position Sensor). These sensors are located at the rear of the hopper

assembly at the 11 o’clock position forPS28 and at the 12 o’clock position forPS4. The state of these sensors will switch from 0 to 1 if the bottle is moved.

Note : To view a PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:

http://www.adobe.com/products/acrobat/readstep2.html .

8. Excessive toner misting due to openings in Toner supply holding main body (p/n 26NA32311E).

Clean the partthoroughly with alcohol.Applya coveringlike electrical tape to cover the openings as shown in the attached file.

CAUTION :Do not cover the opening from which the toner is added to the developer.

50GE33152F part# of the new index ring

Sorry I cannot order the parts myself. I just fix them and send tell another section what part I need.