PinGuard, XP-SK32 Keypad Standalone Reader Instructions Manual Features: Pin Mode Standalone Access Control System. 32 sets of 4 digits pin numbers. Built-in relay. ABS casing. Stylish design. Simple to use. Cold Start When start using the CodeProx for the time, it is advised to coldstart the system to clear the internal memory and reset the system to default setting. Upon switching on the unit, it will enter power up mode and the RED LED will be blinking for 10 seconds. During this moment press the exit button for approximately 2 seconds to ColdStart the system. Note: After coldstart, AutoPin Mode is turned OFF by default. After programming new Pin, remember to enable AutoPin Mode through Programming Mode or using SuperPin. Programming Mode To access the programming mode, user has to press *(asterisk) followed by the Master Pin number (Default = 123456). SuperPin This is a shortcut to enable or disable AutoPin Mode. In idle mode, press *(asterisk) and the the 6 digits SuperPin to enable or disable the AutoPin Mode (Default = 987654). Wiring Diagram 29 Mar 2004 Copyright @ MicroEngine +12 0V N/O N/C L/RET D/S P/B 0V From +12V regulated power supply ( min 2A) EM Lock Magnetic contact Exit Push Button + _ _ +

KNX Room PinGuard XP-SK32 user manual

Embed Size (px)

Citation preview

Page 1: KNX Room PinGuard XP-SK32 user manual

PinGuard, XP-SK32Keypad Standalone Reader

Instructions ManualFeatures:– Pin Mode Standalone Access Control System.– 32 sets of 4 digits pin numbers.– Built-in relay.– ABS casing.– Stylish design.– Simple to use.

Cold StartWhen start using the CodeProx for the time, it is advised to coldstart the system to clear the internal memory and resetthe system to default setting.

Upon switching on the unit, it will enter power up mode and the RED LED will be blinking for 10 seconds. During thismoment press the exit button for approximately 2 seconds to ColdStart the system.

Note: After coldstart, AutoPin Mode is turned OFF by default. After programming new Pin, remember to enable AutoPinMode through Programming Mode or using SuperPin.

Programming ModeTo access the programming mode, user has to press *(asterisk) followed by the Master Pin number (Default = 123456).

SuperPinThis is a shortcut to enable or disable AutoPin Mode. In idle mode, press *(asterisk) and the the 6 digits SuperPin toenable or disable the AutoPin Mode (Default = 987654).

Wiring Diagram

29 Mar 2004 Copyright @ MicroEngine

+12 0V N/O N/C L/RET D/S P/B 0V

From +12V regulated power supply ( min 2A)

EM Lock

Magnetic contact

Exit Push Button+_

_+

Page 2: KNX Room PinGuard XP-SK32 user manual

Programming Mode01...32: Pin Number- Location of the 32 sets of AutoPIN numbers.

- Enter one of the 2-digit number between 02 and 32.- Key in the 4 digits AutoPIN number.- Press # to confirm.

51: MasterPIN- Change the MasterPIN to enter programmingmode.- Default = 123456

- Press 51.- Kein in a 6 digits new MasterPIN number.- Press # to confirm.

52: SuperPIN- Change the SuperPIN to enable or disableAutoPIN Mode in idle state.- Default = 987654

- Press 52.- Kein in a 6 digits new SuperPIN number.- Press # to confirm.

61: AutoPIN Mode- To enable or disable AutoPIN Mode.

- Press 61.- Press 1 to enable or 0 to disable AutoPIN Mode.- Press # to confirm.

62: Security Mode- To turn ON or turn OFF the security of thesystem.

- Press 62.- Press 1 for ON or 0 for OFF.- Press # to confirm.

71: Door Open Time- To set door open duration in second.

- Press 71.- Enter the required duration (0 – 99 sec.).- Press # to confirm.

72: Lock Release Time- To set lock release duration in second.

- Press 72.- Enter the required duration (0 – 99 sec.).- Press # to confirm.