c- L In association with Wright Engineers Ltd & Golder Associates I ; DRAFT Report No. 3 rehminary eport on Hat Creek Openpit No. 2 r r Volume II to ritish Columbia Hydro and Power Authority London June 1976

L Wright Engineers Ltd & Golder Associates Icmscontent.nrs.gov.bc.ca/geoscience/Coal/CoalBC/FiguresandTables/... · Bucket-Wheel Excavator - Cross-Section of Pit Superficials - Diagrammatic

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

  • c- L

    In association with

    Wright Engineers Ltd & Golder Associates I ;

    DRAFT Report No. 3

    rehminary eport on Hat Creek Openpit No. 2

    r

    r

    Volume II

    to

    ritish Columbia Hydro and Power Authority

    London June 1976

  • LIST OF PLATES

    r

    -

    Plates 1 to 14

    Plate 15R

    Plates 16 to 46

    Plate 47

    Plate 48

    Plate 49

    Plate 50

    Plate 51

    Plate 52

    Plate 53

    Plate 54

    Plate 55

    Plate 56

    Plate 57

    Plate 58

    Plate 59

    Plate 60

    Plate 61

    Plate 62

    Plate 63

    Plate 64

    Plate 65

    Plate 66

    Plate 67

    - See Report No 2

    - Legend of Symbols used on Geological Plans and Sections

    - See Report No 2

    - Section 20,000 E

    - Section 22,000 E

    - Sectio~n 24,000 E

    - Section 45,000 N

    - Section 48,000 N

    - Section 51,000 N

    - Section 53,500 N

    - Section 55,000 N

    - Section 57,500 N

    - Section 60,000 N

    - Section 61,500 N

    - Section 63,000 N

    - Isopachytes of Superficial Deposits

    - Isopachytes of Total Overburden

    - Contours at Base of Superficials

    - Contours at Base of Volcanics

    - Contours at Top of Coal

    - Location of Mud Slide Areas and Road Re-Routing

    - Diagram of Mining Concepts

    - Surface Intercepts of the Stages of Pit Development to 2,000-ft Elevation

    - Cumulative Waste Volumes v Cumulative Tonnage of In-Situ Coal (Openpit No 1 and 2)

    c

  • - ii -

    Plate 68

    Plate 69

    Plate 70

    Plate 71

    Plate 72

    Plate 73

    Plate 74

    Plate 75

    Plate 76

    Plate 77

    Plate 78

    Plate 79

    Plate 80

    - Coal Requirements for a 3 x 750-MW Power Station, Yearly Waste Removal, Yearly Stripping Ratio (Openpit No 1 and 2)

    - Cumulative Coal Requirements for a 3 x 750-MW Power Station and Cumulative Waste Removal (Openpit No 1 and 2)

    - Mean Haulage Distances

    - Sequence of Superficial Removal by Bucket-Wheel Excavator

    - Cross-Section of Pit Superficials

    - Diagrammatic Layout of Scheme for Superficial Removal by Bucket-Wheel Excavator

    - Power Distribution System for Ultimate Pit

    - Washability Characteristics of Typical Hat Creek Coal

    - Loring Sample from Borehole No 75-74 Replotted to show Effect of Moisture

    - Plan of Areas Available for Superficials, Pit Waste and Ash Disposal

    - Plan of Superficials, Pit Waste and Ash Disposal - Pit to year 2020

    - Plan of Superficials, Pit Waste and Ash Disposal - 600-ft Pit

    - Production Cost and Uniform Selling Price

  • PLATE 151

    LEGEND OF SYMBOLS USED ON GEOLOGICAL PLANS AND SECTIONS

    sup e rf i e i a 1 s _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ y!j

    ::.:-:.:,:.:.:-:-:.:.:.:.:-:.:.:,:,

    Valcanlcs ____________.__ _ ..____._.__... ___ ____ [W?J

    Marble ____ _ ________ _ _..________..._.___.____ -

    Borehole on plan slth reference no. __ _ __. . __ ___. _ _ -.0’&-14

    -iF- Borehole on section with relerenco no . . . .._.______ ___

    Fault on plan with direction of downthrow ________. -+-

    Fault on plan under volcanic5 _________________ ____ -. c --.-.-

    Fault on section with direction of throw. _. _ .__. . .

    Contours within area ot incrop ___.___ _ ____ ___ ___ --??‘oo----

    (value in feet above datum)

    Contours outside area ot incrop __..____.._..__..._ -l!Zk-

    (value in feet above datum)

    isopachytes (value in feet) ._ _. . _._ _ _ __ ___ _ ____ .-.A’-

    ABRREVtATlONS

    S5 = Sandstone Carb = Carbonaceous

    Sh = Shale Cl = Clay stone

    Si = SIltstone A9 = Agglomerate

    c9 = Conglomerate B = Breccia

    C = Coaly Bas = Basalt

    PD-NCB Consultants Ltd., London.

    Eng’r. Dote org. No. J. B. May 76 605ll5R

  • PLATE 65 .

    DIAGRAM OF MINING CONCEPTS

    Not to scale

    SCHEME A

    North

    South

    SCHEME B

  • L,

    L.,.

    .

    r

    .

    r

    .

    c . ,

    c

    .

    I

    .

    c

    .

    r

    .

    i --

    P

    b.

    CUMULATIVE WASTE VOLUMES V. CUMULATIVE TONNAGE OF INSITU COAL

    (OPENPIT ~0~. I 8 2)

    1100 r

    900

    0 100 200 300 400 500

    IN SITU COAL 106 5. TONS

    Uponpit No. / shown to stage 8. *dOO N pit”

    Opsnpir No. 2 shown to yQOr 2020, 3Syeors Nfo

    PD-NCfoCoodtans Ltd. .

    Eng’r. M. A.

  • COAL REQUIREMENTS FOR A 3 x 750 MW POWER STATtON

    YEARLY WASTE REMOVAL

    YEARLY STRIPPING RATIO

    ( OPENPIT Nos. I fi 2)

    OPENPIT No PI7 STAGE

    16

    1 ’ I IN SITU COAL A670 Etu I ib 39% WASTE AN0 ASH ----

    POWER STATION FUEL 6000 Btul lb 28*bAStt : I I

    I ,

    f

    I I

    I I i I

    2015 2020

    I I I I I I I I I 1 2 3 4 5 6 7 8

    OPENDIT Nn. 2 PIT STAGE r I 1 I I I

    1 2 3 A 5 6

    P D-NCBLznyosnyltants Ud.,

  • c

    . . -

    e-1

    c

    c-

    . .

    F

    . .

    c-

    .

    .

    r .

    .

    c-

    .

    c

    .

    r-

    c -

    I

    .

    . _

    .

    - -

    I -

    .

    r .

    .

    c-

    .

    I -

    .

    c-

    .

    CUMULATlVE COAL REQUIREMENTS FOR A 3x 750 MW POWER STATION

    AND CUMULATIVE WASTE MATERIAL

    ( OPENPIT NOS. I 8 2)

    PLATE 69

    1lOC

    1000

    so0

    800

    700

    600

    500

    400

    300

    200

    100

    600

    500

    3

    OPENPIT No 1 PIT STAGE 1 I I I I I I I I

    1 2 3 * 5 6 7 6

    OPENPIT No 2 I I I I I ! PIT STAGE 1 2 3 4 5 6

    YEARS

    1 PD-NC9 Consultants Ltd.,

    1 J.B. June 76 605/69

    -

  • PLATE 7C

    MEAN HAULAGE DISTANCES

    t SUPERFICIALS I

    WllHOlJf SOUTH CONVEYOR INSTALLED

    I

    WITH SOUTH CONVEVOR INSTALLED

    1

    WASTE

    VOLCANICS

    I I

    COAL

    0 I I I I I I 1 1

    YEAR 1980 1935 1990 1995 2300 2005 2010 2015 2020

    PIT STAGE I I I I I 1

    1 2 3 I 5 6

    P D-NCB&~ult.nts Ltd.

    Eng’r. J. 8.

  • CROSS SECTION OF PIT SUPERFICIALS PIT No.2

    PL ATE72

    VOLUMETRIC, CENTRE . I

    PIT LIMIT , I PIT LIMIT 1

    SECT ION ‘AA’ I I

    ‘8’ . .

    B PIT LIMIT PIT LIUIT

    c

    SECT ION ‘88’

    PIT LIMIT PIT LIYI 1

    I

    PIT LIMIT

    PIT LIMIT

    FOR SEC 7lON IOENTlFlCATlON HORIZONTAL XALE

    SEE PLATE 71 VERTICAL SCALE

    PD NC~o~;~;u ltantr Ltd,

  • OPENPIT No. 2

    D I AGR AMMATIC LAYOUT OF SCHEME FOR SUPERFICIAL REMOVAL

    BY BUCKET WHEEL EXCAVATOR

    direction

    high dump /

    advance

    bucket wheel -w /.- --~

    excavator _ -

    .

  • PLATE 74 _ -__.- - _ c.

    c-

    .

    m

    .

    r

    c

    c-

    c

    c

    r

    ,

    r

    r.

    L

    r-

    .

    r-

    L

    POWER DISTRI8UTION SYSTEM FOR ULTIMATE PIT

    ,, 60 k V INCOMING ” AND METERING

    6 HVA 60112.5 kV ( 3 TRANSFORMERS) 6 MVA 6014.12 II V ( 2 TRANFORMERS )

    O.H. LINE

    ” LF----------

    I

    1 ---- -x1 --1 * I SHf’iEL (5)

    I CONVEYOR ----- I X-’ I

    ’ FOR INCLUSION

    i t- I

    CONVEYOR X-l ----- I

    IF BWE IS USED

    t t I

    LIGHTING I FEEDER BWE

    k---x- 8

    ----- AJXILIARES STATION

    I Xl I

    , ,

    SHOtz- ”

    CONYEYOR

    I

    --- - -x -I

    XL

    I * CONVEYOR I -----

    t- ----------

    f s-

    ,/ BENCH CABLE

    + c SHOYEL (S) DRILL (S)

    L!GHTIYGI FEEDER AUX:LIARES STATION y BENCH CABLE A

    4

    i n

    SHOVEL (5) DRILL (5) ii ?

    Si!OVEL (5.) % i FEEDER

    AUXILIARIES STATION d

    v RENCH CABLE n

    ’ i

    4 + S SIDE

    SHOVEL (S) DRILL (S) WASTE DUMP ,

    IN PIT CONVEYOR +I I,

    I A-

    IN PIT CONVEYOR I I

    IN PIT CONVEYOR

    -+ I

    WASTE SLEWING BOOM CONVEYOR CONVEYOR CONVEYOR

    I :I”

    IN PIT CONYEYOR

    IN FIT CONVEYOR-----jtl s I

    AJ++ IN PIT CONVEYOR

    IN PIT CONVEYOR --++-I $ “, ;

    ; i 2 ,--& IN PIT CONVEYOR

    IN PiT CONVEYOR --+--I I

    LX--I PD-NCBCC~~ultontr Ltd.

  • PLATE t!

    WASHABILITY CHARACTERISTICS OF A TYPICAL HAT CREEK COAL

    BOREHOLE No 75-74

    -

    0=

    53

    ii O-” o-

    \t, Q o- J

    i Ill

    F 20- F !

    20-

    2 P -I LL

    LO- ; LO-

    it

    >” 60- w

    F: 2 6o

    < k -----

    4 g oo- so-

    I:

    too (o) ’ ’

    SPECIFIC GRAVITY OF FLOATS CuMUlAtlvE CV OF FLOATS IO’ BTU/lb

    ,I-”

    a 5-

    r”

    s 0 I I I I I

    t.9 I*9 l-7 l.6

    04

    I.5 I.4

    SPECIFIC GRAVITY OF FLOATS CUMULATIVE CV ff FLOATS IO’ BTU/lb 4 % 2 o- w

    -% \ 20-

    N.C.B. SAMPLE MINUS 'l4i1-1 P

    0" -- -- LORING SAMPLE MiWS ‘12 jn

    LO -

    2

    w

    L 60-

    l- a NOTE: ALL FIGURES ARE ON ii 60 -

    I A DRY BASIS

    2. too+ c

    (4 . O

    10 20 30

    CUMULATIVE ASH IN FLQA7S”/o

  • LORING SAMPLE FROM BOREHOLES El2 75-74

    REPLOTTED TO SHOW EFFECT OF MOISTURE

    . PLATE 76 ,

    40 - XB

    4 35- 0 I- \ v 0” 30- ‘\XA

    $2 ‘\.X C a 25 - \ P

    ii! zo- ‘\.pb

    z

    A=ASSUMED ROM (PD-NCB) 1%

    I

    z l5 - B= ASSUMED IN SITU COAL (PD-N

    5 10 - c -x -ASSUMED BOILER FEED (DCA)

    s-

    0 I I I I I I I 0 1 2 3 4 5 6 ? 8 9 10 II 12 13

    CALORIFIC VALUE IO’ BTU/lb

    (4

    loo/o ASH

    UNWASHED

    22.4% ASH

    WASHED TO

    IS% ASH WASHERY

    REJECTS

    FEED TO

    BOILERS

    EFFECT OF VARIOUS DEGREES OF WASHING

    PD-NC? Cyvultants Ltd.

    Dcte

  • ,

    L

    c-

    L

    *--

    .

    r

    .

    .

    .

    r

    .

    r-

    .

    r

    .

    *

    .

    .r-

    .

    r

    .

    r

    .

    *

    L

    r-

    t .

    r

    .

    P-

    .

    c--

    .

    L--

    PRODUCTION COST AND UNIFORM SELLING PRICE

    (Uninflated 1975 prices)

    PLATE 80

    -.-. aDEHP/r Nat

    - VPENPll N-2

    15

    5

    0

    1950131 2 b 6 8 1990191 2 4 6 8 200011 2 4 6 6 2010111 2 4 6 8 2020121

    YEAR

    PD NCBLvnyouAt.ants Ltd