Upload
jerry-massey
View
51
Download
2
Embed Size (px)
DESCRIPTION
LABELING OF BARREL ALIGNMENT CABLES. Inplane system cables Praxial and Axial cables Projective system cables Reference system cables Chamber to Chamber Connection (CCC) cables BIR-BIM cables RASMUX cabling scheme Appendix: Exceptions to the previous rules. . RASCAM Lens RASLED. z. - PowerPoint PPT Presentation
Citation preview
26/04/2006 1
LABELING OF BARREL ALIGNMENT CABLES
•Inplane system cables•Praxial and Axial cables•Projective system cables•Reference system cables•Chamber to Chamber Connection (CCC) cables•BIR-BIM cables•RASMUX cabling scheme
•Appendix: Exceptions to the previous rules
26/04/2006 2
HV side
BIL6BIL5BIL4BIL3
RO side
BIL1 BIL2
The various systems on a chamber (1)
RASCAMLensRASLED
Ex: BIL Standard sectors (side A)
projective Reference systemprojective
BIL-BISConnection(CCC)
B-sensor platforms
Chambers are seen from the interaction point.
z
BIL-BISConnection(CCC)
praxial axial
26/04/2006 3
Reference system SACLED
Projective system RASLED (ray 2,3,4)
BIL
BIS
CCC SACLED
Projective system RASLED (ray 1)
Praxial proximityAxial
B-sensor
B-sensor
The various systems on a chamber (2)
Ex: BIL-BIS Standard sectors (side A)
CCC SCAM
26/04/2006 4
Naming conventions
The <cable type> are: RL : Rasnik Led RC : Rasnik CCD SL : SacLed SC : Scam CCDThe <sensor types> are: INP : Inplane PRA : Praxial AXI : Axial PRO : Projective REF : Reference CCC : Chamber to chamber connection BRM : BIR-BIM connectionFor the <location type> the following abbreviations are mixed together:
A : for A side C : for C side RO : readout side HV : high voltage side
1,2,3,4: when no other location can be indicatedThe <option> is the chamber_name: when a cable comes from another chamber
The cable name, consists of 3 (or 4) parts: <cable type>_<sensor type>_<location type>_<option>
Remark: SacLed and Scam CCD are used for Reference and CCC connection
26/04/2006 5
Inplane cables η=0
MDT
21
MDT
2
Remark: Normally the RASLED are on the HV side and the RASCAM on the RO side
HV side
RO side
A sideC side
4 3 2 1
1
1 2 3 4
RC_INP_RO2 (RasCam 2)
RC_INP_RO1 (RasCam 1)RC_INP_RO1 (RasCam1)
RC_INP_RO2 (RasCam 2)
RL_INP_HV4 (RasLed 4)
RL_INP_HV3 (RasLed 3)
RL_INP_HV2 (RasLed 2)
RL_INP_HV1 (RasLed 1)
RL_INP_HV4 (RasLed 4)
RL_INP_HV3 (RasLed 3)
RL_INP_HV2 (RasLed 2)
RL_INP_HV1 (RasLed 1)
26/04/2006 6
Inplane cables BOG
Remark: the RASLED are on the RO side and the RASCAM on the HV side
HV side
RO side
A sideC side
RC_INP_HV2 (RasCam 1)
RC_INP_HV1 (RasCam 2)RC_INP_HV1 (RasCam3)
RC_INP_HV2 (RasCam 4)
RL_INP_RO4 (RasLed 8)
RL_INP_RO3 (RasLed 7)
RL_INP_RO2 (RasLed 6)
RL_INP_RO1 (RasLed 5)
RL_INP_RO4 (RasLed 1)
RL_INP_RO3 (RasLed 2)
RL_INP_RO2 (RasLed 3)
RL_INP_RO1 (RasLed 4)
MDT
26/04/2006 7
Praxial labels
η
RL_PRA_CHV (RasLed, CHV corner)RC_PRA_CHV (RasCam, CHV corner)
HV side
RO side
RL_PRA_CRO (RasLed, CRO corner)RC_PRA_CRO (RasCam, CRO corner)
RL_PRA_AHV (RasLed, AHV corner)RC_PRA_AHV (RasCam, AHV corner)
RL_PRA_ARO (RasLed, ARO corner)RC_PRA_ARO (RasCam, ARO corner)
MDT A sideC side
26/04/2006 8
Axial labels
MDT ηA sideC side
RL_AXI_CHV (RasLed, CHV corner)RC_AXI_CHV (RasCam, CHV corner)
RL_AXI_AHV (RasLed, AHV corner)RC_AXI_AHV (RasCam, AHV corner)
RL_AXI_ARO (RasLed, ARO corner)RC_AXI_ARO (RasCam, ARO corner)
RL_AXI_CRO (RasLed, CRO corner)RC_AXI_CRO (RasCam, CRO corner)
Remark: Not all the labels indicated here, have to be present on the chamber !
RO side
HV side
26/04/2006 9
Projective labels
BIL BOL
RL_PRO_HV (RasLed, HV side)
RC_PRO_RO (RasCam, RO side)RL_PRO_RO (RasLed, RO side)
RC_PRO_HV (RasCam, HV side)
RO side
HV side
26/04/2006 10
Reference labels (MDT)
MDT
SL_REF_HV (SacLed, HV side)
SL_REF_RO (SacLed, RO side)
HV side
RO side
26/04/2006 11
Reference labels (plates on toroid ribs)
SC_BML_RI (SCam to BML)
SC_BIL_RI (SCAm to BIL)SC_BIL_LE (SCAm to BIL)
SC_BML_LE (SCam to BML)
Right sideLeft side
CCD labels:
SC_PLC_LE (SCam to next coil) SC_PLC_RI (SCam to next coil)
SC_PLR_RI (SCam to next rib)SC_PLR_LE (SCAm to next rib)
26/04/2006 12
Reference labels (plates on toroid ribs)
Right sideLeft side
Led labels:
SL_PLC_LE (SacLed to next coil) SL_PLC_RI (SacLed to next coil)
SL_PLR_RI (SacLed to next rib)SL_PLR_LE (SacLed to next rib)
26/04/2006 13
CCC labels
MDT
MDT
HV side
SL_CCC_HV (SacLed, HV side)
SL_CCC_RO (SacLed, RO side)
SC_CCC_HV (SCam, HV side)
SC_CCC_RO (SCam, RO side)
RO side
HV side
26/04/2006 14
BIR-BIM labels (sector 11)
BIR
BIMBIM
η=0
A sideC side
HV side
RO side
4 3 2 1 1 2 3 4
RC_BRM_HV (RasCam)RC_BRM_HV (RasCam)
z
RL_BRM_RO1
RL_BRM_RO2
RL_BRM_RO3
RL_BRM_RO4
RL_BRM_RO1
RL_BRM_RO2
RL_BRM_RO3
RL_BRM_RO4
BIRBIR BIR
26/04/2006 15
BIR-BIM labels (sector 15)
z
η=0
A sideC side
HV side
RO side
4 3 2 1 1 2 3 4
RC_BRM_HV (RasCam)RC_BRM_HV (RasCam)
BIM
BIR
BIM
RL_BRM_RO4
RL_BRM_RO1
RL_BRM_RO2
RL_BRM_RO3
RL_BRM_RO4
RL_BRM_RO1
RL_BRM_RO2
RL_BRM_RO3
z
BIR BIRBIR
26/04/2006 16
Special labels (<option>)The following cables need an <option> extension:
SC_CCC_HV => SC_CCC_HV_BIS2 for BIS2A08 and BIS2C08SC_CCC_RO => SC_CCC_RO_BIS2 for BIS2A08 and BIS2C08
SC_CCC_HV => SC_CCC_HV_BOS2 for BOS2A and BOS2C, sector 2,4,6,8,10,16SC_CCC_RO => SC_CCC_RO_BOS2 for BOS2A and BOS2C, sector 2,4,6,8,10,16
SC_CCC_HV => SC_CCC_HV_BOS5 for BOS5A and BOS5C, sector 2,4,6,8,10,16SC_CCC_RO => SC_CCC_RO_BOS5 for BOS5A and BOS5C, sector 2,4,6,8,10,16
SC_CCC_HV => SC_CCC_HV_BOF7 for BOF7A and BOF7C, sector 12,14SC_CCC_RO => SC_CCC_RO_BOF7 for BOF7A and BOF7C, sector 12,14
RC_PRO_HV => RC_PRO_HV_BOL2 for BOL2A and BOL2C, sector 1,3,5,7,9,11,15RC_PRO_RO => RC_PRO_RO_BOL2 for BOL2C and BOL2C, sector 1,3,5,7,9,11,15
26/04/2006 17
RASMUX CABLING SCHEME (Chambers)
RL_INP_HV1
RL_INP_HV3
RL_INP_HV2
RL_INP_HV4
A
RL_ PRA_AHV
RL_ PRA_CHV
RL_ PRA_ARO
RL_ PRA_CRO
A
RL_ AXI_XHV
RL_ PRO_HV
RL_ AXI_XRO
RL_ PRO_RO
A
SL_REF_HV
SL_ CCC_HV
SL_ REF_RO
SL_ CCC_RO
RA
S(S
AC
)LE
D
RC_INP_RO1
RC_INP_RO2
RC_ PRA_AHV
RC_ PRA_ARO
RC_ PRA_CHV
RC_ PRA_CRO
RC_AXI_XHV
RC_ AXI_XRO
RA
S(S
)CA
M
Remark: standard MDT with NO Projective, CCC or BIR-BIM CCD
1
24
3
B
5
68
7
B
9
1012
11
B
13
1416
15
8 7 6 5 4 3 2 18 7 6 5 4 3 2 1
26/04/2006 19
RASMUX LED CABLING SCHEME (2)
Inplane
Praxial
Axial
Projective
BIL1-2
CCC
Exception 1: BIL2 sector 9 (BIL1-BIL2 connection), 2 chambers
Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : RL_PRA_AHV or emptySlot 6 : RL_PRA_ARO or emptySlot 7 : RL_PRA_CHV or emptySlot 8 : RL_PRA_CRO or emptySlot 9 : RL_AXI_AHV or RL_AXI_CHVSlot 10: RL_AXI_ARO or RL_AXI_CROSlot 11: RL_PRO_HVSlot 12: RL_PRO_ROSlot 13: SL_CCI_HVSlot 14: SL_CCI_ROSlot 15: SL_CCC_HVSlot 16: SL_CCC_RO
26/04/2006 20
RASMUX LED CABLING SCHEME (3)
Exception 2: BIM1 (BIR-BIM connection)
BIM1 sector 11 and 15 (4 chambers)Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : RL_PRA_AHV or emptySlot 6 : RL_PRA_ARO or emptySlot 7 : RL_PRA_CHV or emptySlot 8 : RL_PRA_CRO or emptySlot 9 : RL_AXI_AHV or RL_AXI_CHVSlot 10: RL_AXI_ARO or RL_AXI_CROSlot 11: RL_BRM_RO1Slot 12: RL_BRM_RO3Slot 13: RL_BRM_RO2Slot 14: RL_BRM_RO4Slot 15: SL_CCC_HV or emptySlot 16: SL_CCC_RO or empty
Inplane
Praxial
Axial
BIR/BIM
BIR/BIM
CCC
26/04/2006 21
RASMUX LED CABLING SCHEME (4)
Exception 3: BIM4 (BIR-BIM connection)
BIM4 sector 11, 15 (4 chambers):Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : RL_PRA_AHVSlot 6 : RL_PRA_AROSlot 7 : RL_PRA_CHVSlot 8 : RL_PRA_CROSlot 9 : RL_AXI_AHV or RL_AXI_CHVSlot 10: RL_AXI_ARO or RL_AXI_CROSlot 11: RL_PRO_HV or emptySlot 12: RL_PRO_RO or emptySlot 13: RL_BRM_RO1Slot 14: EmptySlot 15: RL_BRM_RO2 Slot 16: Empty
Inplane
Praxial
Axial
Projective
26/04/2006 22
RASMUX LED CABLING SCHEME (5)
Inplane
Praxial
Axial
CCC
Exception 4: BIM5 (BIR-BIM connection)
BIM5 sector 11 (2 chambers):Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : RL_PRA_AHVSlot 6 : RL_PRA_AROSlot 7 : RL_PRA_CHVSlot 8 : RL_PRA_CROSlot 9 : RL_AXI_AHV or RL_AXI_CHVSlot 10: RL_AXI_ARO or RL_AXI_CROSlot 11: RL_PRO_HVSlot 12: RL_BRM_RO3Slot 13: RL_REF_HV Slot 14: RL_BRM_RO4 Slot 15: SL_CCC_HVSlot 16: Empty
ProjectiveBIR-BIMReferenceBIR-BIM
26/04/2006 23
RASMUX LED CABLING SCHEME (6)
Inplane
Praxial
Axial
CCC
Exception 5: BIM5 (BIR-BIM)
BIM5 sector 15 (2 chambers):Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : RL_PRA_AHV or emptySlot 6 : RL_PRA_ARO or emptySlot 7 : RL_PRA_CHV or emptySlot 8 : RL_PRA_CRO or emptySlot 9 : RL_AXI_AHV or RL_AXI_CHVSlot 10: RL_AXI_ARO or RL_AXI_CROSlot 11: RL_BRM_RO3Slot 12: RL_PRO_ROSlot 13: RL_BRM_RO4 Slot 14: RL_REF_RO Slot 15: EmptySlot 16: SL_CCC_RO
BIR-BIMProjectiveBIR-BIMReference
26/04/2006 24
RASMUX LED CABLING SCHEME (7)Exception 6: BMF1A (no praxials), BMF2A (4 Axials), BMF3A, sectors 12,14
BMF1A (2 chambers):Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : EmptySlot 9 : RL_AXI_CHVSlot 10: RL_AXI_CROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty
BMF2A (2 chambers):Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : RL_AXI_AHVSlot 6 : RL_AXI_AROSlot 7 : EmptySlot 8 : EmptySlot 9 : RL_AXI_CHVSlot 10: RL_AXI_CROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty
BMF3A (2 chambers):Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : EmptySlot 9 : RL_AXI_AHVSlot 10: RL_AXI_AROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty
26/04/2006 25
RASMUX LED CABLING SCHEME (8)Exception 6: BMF1C (no praxials), BMF2C (4 Axials), BMF3C, sectors 12,14
BMF1C (2 chambers):Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : EmptySlot 9 : RL_AXI_AHVSlot 10: RL_AXI_AROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty
BMF2C (2 chambers):Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : RL_AXI_CHVSlot 6 : RL_AXI_CROSlot 7 : EmptySlot 8 : EmptySlot 9 : RL_AXI_AHVSlot 10: RL_AXI_AROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty
BMF3C (2 chambers):Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : EmptySlot 9 : RL_AXI_CHVSlot 10: RL_AXI_CROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty
26/04/2006 26
RASMUX LED CABLING SCHEME (9)Exception 7: BML4, sectors 13 = 2 Aluminium Frames for the elevator
BML4A (1 alu frame)Slot 1 : EmptySlot 2 : EmptySlot 3 : EmptySlot 4 : EmptySlot 5 : RL_PRA_AHVSlot 6 : RL_PRA_AROSlot 7 : RL_PRA_CHVSlot 8 : RL_PRA_CROSlot 9 : RL_AXI_CHVSlot 10: RL_AXI_CROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty
BML4C (1 alu frame)Slot 1 : EmptySlot 2 : EmptySlot 3 : EmptySlot 4 : EmptySlot 5 : RL_PRA_AHVSlot 6 : RL_PRA_AROSlot 7 : RL_PRA_CHVSlot 8 : RL_PRA_CROSlot 9 : RL_AXI_AHVSlot 10: RL_AXI_AROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty
26/04/2006 27
RASMUX LED CABLING SCHEME (10)Exception 8: BOLE, sectors 13 = 2 Aluminium Frames for the elevator
BOLE (2 alu frames)Slot 1 : EmptySlot 2 : EmptySlot 3 : EmptySlot 4 : EmptySlot 5 : RL_PRA_AHVSlot 6 : RL_PRA_AROSlot 7 : RL_PRA_CHVSlot 8 : RL_PRA_CROSlot 9 : EmptySlot 10: EmptySlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty
26/04/2006 28
RASMUX LED CABLING SCHEME (11)Exception 9: BOG0, sectors 12 and 14 (2 chambers), 8 inplanes: 2 Rasmux used
BOG0 RasMux ASlot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV4Slot 3 : RL_INP_HV5Slot 4 : RL_INP_HV8Slot 5 : RL_PRA_AHVSlot 6 : RL_PRA_AROSlot 7 : EmptySlot 8 : Empty Slot 9 : RL_AXI_CHVSlot 10: RL_AXI_CROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty
BOG0 RasMux CSlot 1 : RL_INP_HV2Slot 2 : RL_INP_HV3Slot 3 : RL_INP_HV6Slot 4 : RL_INP_HV7Slot 5 : EmptySlot 6 : EmptySlot 7 : RL_PRA_CHVSlot 8 : RL_PRA_CROSlot 9 : RL_AXI_AHVSlot 10: RL_AXI_AROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty
26/04/2006 29
RASMUX LED CABLING SCHEME (12)Exception 10: BOG2/4/6, sectors 12 and 14 (12 chambers), 8 inplanes: 2 Rasmux used
BOG2/4/6 A RasMux 1Slot 1 : RL_INP_RO1 Slot 2 : RL_INP_RO4Slot 3 : RL_INP_RO5Slot 4 : RL_INP_RO8Slot 5 : RL_PRA_AHVSlot 6 : RL_PRA_AROSlot 7 : RL_PRA_CHVSlot 8 : RL_PRA_CRO Slot 9 : RL_AXI_CHV Slot 10: RL_AXI_CROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty
BOG2/4/6 A RasMux 2Slot 1 : RL_INP_RO2 Slot 2 : RL_INP_RO3Slot 3 : RL_INP_RO6Slot 4 : RL_INP_RO7Slot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : Empty Slot 9 : Empty Slot 10: EmptySlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty
26/04/2006 30
RASMUX LED CABLING SCHEME (13)Exception 11: BOG8, sectors 12 and 14 (4 chambers), 8 inplanes
BOG8 RasMux Slot 1 : RL_INP_RO1 Slot 2 : RL_INP_RO4Slot 3 : RL_INP_RO5Slot 4 : RL_INP_RO8Slot 5 : RL_PRA_AHVSlot 6 : RL_PRA_AROSlot 7 : RL_PRA_CHVSlot 8 : RL_PRA_CRO Slot 9 : RL_AXI_CHV Slot 10: RL_AXI_CROSlot 11: RL_INP_RO2Slot 12: RL_INP_RO3Slot 13: RL_INP_RO6Slot 14: RL_INP_RO7Slot 15: EmptySlot 16: Empty
26/04/2006 31
RASMUX LED CABLING SCHEME (13)Exception 12: BOS6, all sectors
BOS6A RasMux Slot 1 : RL_INP_RO1 Slot 2 : EmptySlot 3 : RL_INP_RO4Slot 4 : EmptySlot 5 : EmptySlot 6 : EmptySlot 7 : RL_PRA_CHVSlot 8 : RL_PRA_CRO Slot 9 : RL_INP_RO2Slot 10: EmptySlot 11: RL_INP_RO3Slot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty
BOS6C RasMux Slot 1 : RL_INP_RO1 Slot 2 : EmptySlot 3 : RL_INP_RO4Slot 4 : EmptySlot 5 : RL_PRA_AHVSlot 6 : RL_PRA_AROSlot 7 : EmptySlot 8 : EmptySlot 9 : RL_INP_RO2Slot 10: EmptySlot 11: RL_INP_RO3Slot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty
26/04/2006 32
RASMUX CCD CABLING SCHEME (1)Default chamber:
Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHV or RC_AXI_CHVSlot 8 : RC_AXI_ARO or RC_AXI_CRO
The chamber which makes exception to this scheme are chamber with an Projective, CCC or Bir-Bim CCD cable (174 exceptions).
This are: Name Sector Amount 1.) BIS1 and BIS7 all sectors 32 2.) BIL1 sector 9 2 3.) BIR1 sector 11 and 15 4 4.) BIR2 sector 11 and 15 4 5.) BIR4 sector 11 and 15 4 6.) BIR5 sector 11 and 15 4 7.) BMS1 sector 2,4,6,8,10,16 12 8.) BMS4 sector 2,4,6,8,10,16 12 9.) BMS5 sector 2,4,6,8,10,16 12 10.) BMF1-BMF3 sector 12 and 14 12 11.) BOS1 sector 2,4,6,8,10,16 12 12.) BOS6 sector 2,4,6,8,10,16 12 13.) BOG0 sector 12 and 14 2 14.) BOG2/4 sector 12 and 14 8 15.) BOG6/8 sector 12 and 14 8 16.) BOL1 sector 1,3,5,7,9,11,15 14 17.) BOL3, BOL4 sector 13 4 18.) BOL4 sector 1,3,5,7,9,11,15 14 19.) BOL6 sector 1,3,5,7,9,13 12 20.) BOL6 sector 11,15 4
26/04/2006 33
RASMUX CCD CABLING SCHEME (2)
Rule for Projective, CCC, BIM/BIM CCD cables (see schemes here after):
a) In the above scheme fill the empty slots in the following order: 1. RC_PRO_HV 2. RC_PRO_RO 3. RC_CCC_HV 4. RC_CCC_RO 5. RC_BRM_HV 6. RC_BRM_HV
b) If all Rasmux CCD slots are occupied go to the neighboring MDT: BOS2=>BOS1, BOS5=>BOS6, BOL2=>BOL1, BOF7=>BOG8 or neighbouring alu-plate: BOL3A13, BOL4A13 => ALO3A13 BOL3C13, BOL4C13 =>ALO3C13 or use a second RASMUX, this is the case for BOL4, BOF1
26/04/2006 34
RASMUX CCD CABLING SCHEME (3)
BIS1 sector 2,4,6,12,14 (10 chambers):
Slot 1 : RC_INP_RO1 Slot 2 : EmptySlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : SC_CCC_HVSlot 8 : SC_CCC_RO
Exception 1: BIS1 (CCC connection)
26/04/2006 35
RASMUX CCD CABLING SCHEME (4)
Exception 2: BIS2A10 & BIS2C10 (CCC connection)
BIS1A10:Slot 1 : RC_INP_RO1 Slot 2 : EmptySlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : SC_CCC_RO_BIS2Slot 8 : Empty
BIS2A10:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BIS1C10:Slot 1 : RC_INP_RO1 Slot 2 : EmptySlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : SC_CCC_HV_BIS2Slot 8 : Empty
BIS2C10:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
26/04/2006 36
RASMUX CCD CABLING SCHEME (5)
Exception 3: BIS4 sector 2,4,6,8,10,16 (CCC connection)
BIS4A sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BIS4C sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
BIS3A sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_RO_BIS4Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_AHV
BIS3 sector 2,4,6,8,10,16 (6 chambers) :Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_RO_BIS4Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
26/04/2006 37
RASMUX CCD CABLING SCHEME (6)
BIS7A sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : EmptySlot 3 : SC_CCC_HVSlot 4 : SC_CCC_ROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BIS7C sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : EmptySlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : SC_CCC_HVSlot 6 : SC_CCC_ROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
Exception 4: BIS7 chambers (CCC connection)
26/04/2006 38
RASMUX CCD CABLING SCHEME (7)
BIS1A08:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : EmptySlot 8 : Empty
Exception 5: BIS A chambers with one CCC connection
BIS1A16:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : EmptySlot 8 : Empty
BIS2A08:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BIS2A16:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BIS4A12:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BIS3A12:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
26/04/2006 39
RASMUX CCD CABLING SCHEME (8)
Exception 5: BIS A chambers with one CCC connection
BIS7A14:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : EmptySlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BIS6A14:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BIS7A12:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : EmptySlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BIS6A12:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BIS4A14:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BIS3A14:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
26/04/2006 40
RASMUX CCD CABLING SCHEME (9)
BIS1C08:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : EmptySlot 8 : Empty
Exception 6: BIS C chambers with one CCC connection
BIS1C16:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : EmptySlot 8 : Empty
BIS2C08:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
BIS2C16:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
BIS4C12:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
BIS3C12:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
26/04/2006 41
RASMUX CCD CABLING SCHEME (10)
Exception 6: BIS C chambers with one CCC connection
BIS7C14:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : EmptySlot 6 : EmptySlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
BIS6C14:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
BIS7C12:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : EmptySlot 6 : EmptySlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
BIS6C12:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
BIS4C14:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
BIS3C14:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
26/04/2006 42
RASMUX CCD CABLING SCHEME (11)
Exception 7: BIL1 chambers (no praxial, CCC BIL1-BIL2 connection)
BIL1A09 (1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : EmptySlot 4 : EmptySlot 5 : EmptySlot 6 : EmptySlot 7 : SC_CCC_HVSlot 8 : SC_CCC_RO
BIL1C09 (1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : EmptySlot 4 : EmptySlot 5 : EmptySlot 6 : EmptySlot 7 : SC_CCC_HVSlot 8 : SC_CCC_RO
26/04/2006 43
RASMUX CCD CABLING SCHEME (12)
Exception 8: BIR1 chambers (BIR-BIM connection)
BIR1A011 and BIR1C11 (2 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_BRM_HVSlot 4 : EmptySlot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : Empty
BIR1A15 and BIR1C15 (2 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_BRM_HVSlot 4 : EmptySlot 5 : Empty Slot 6 : EmptySlot 7 : Empty Slot 8 : Empty
26/04/2006 44
RASMUX CCD CABLING SCHEME (13)
Exception 9: BIR2 chambers (BIR-BIM connection)
BIR2A11 (1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_BRM_HVSlot 6 : EmptySlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BIR2C11 (1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_BRM_HVSlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
BIR2A15 ( 1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_BRM_HVSlot 6 : EmptySlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BIR2C15 ( 1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_BRM_HVSlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
26/04/2006 45
RASMUX CCD CABLING SCHEME (14)
Exception 10: BIR4 chambers (BIR_BIM connection)
BIR4A11 ( 1 chamber) :Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_BRM_HVSlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BIR4C11 (1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_BRM_HVSlot 6 : EmptySlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
BIR4A15 ( 1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_BRM_HVSlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BIR4C15 ( 1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_BRM_HVSlot 6 : EmptySlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
26/04/2006 46
RASMUX CCD CABLING SCHEME (15)
Exception 11: BIR5 chambers (BIR-BIM connection)
BIR5A11 (1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_BRM_HVSlot 6 : Empty Slot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BIR5C11 (1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_BRM_HVSlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
BIR5A15 ( 1chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_BRM_HVSlot 6 : EmptySlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BIR5C15 (1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_BRM_HVSlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
26/04/2006 47
RASMUX CCD CABLING SCHEME (16)
Exception 12: BMS1 chambers (CCC connection)
BMS1 sector 2,4,6,10,16 (10 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : SC_CCC_HVSlot 8 : SC_CCC_RO
BMS1A08 ( 1chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : EmptySlot 7 : SC_CCC_HVSlot 8 : SC_CCC_RO
BMS1C08 ( 1chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : SC_CCC_HVSlot 8 : SC_CCC_RO
26/04/2006 48
RASMUX CCD CABLING SCHEME (17)
Exception 13: BMS4 chambers (CCC connection)
BMS4A sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : SC_CCC_HVSlot 4 : SC_CCC_ROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BMS4C sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : SC_CCC_HVSlot 6 : SC_CCC_ROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
26/04/2006 49
RASMUX CCD CABLING SCHEME (18)
Exception 14: BMS5 chambers (CCC connection)
BMS5A sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : SC_CCC_HVSlot 6 : SC_CCC_ROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BMS5C sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : SC_CCC_HVSlot 4 : SC_CCC_ROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
26/04/2006 50
RASMUX CCD CABLING SCHEME (19)
Exception 15: BMF chambers (4 axials) , sectors 12 and 14
BMF1A, (2 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_CCC_HVSlot 4 : RC_CCC_ROSlot 5 : EmptySlot 6 : EmptySlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BMF2A, (2 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_AXI_CHVSlot 4 : RC_AXI_CROSlot 5 : RC_CCC_HVSlot 6 : RC_CCC_ROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BMF3A, (2 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_CCC_HVSlot 4 : RC_CCC_ROSlot 5 : EmptySlot 6 : EmptySlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
BMF1C, (2 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_CCC_HVSlot 4 : RC_CCC_ROSlot 5 : EmptySlot 6 : EmptySlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
BMF2C, (2 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_AXI_AHVSlot 4 : RC_AXI_AROSlot 5 : RC_CCC_HVSlot 6 : RC_CCC_ROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
BMF3C, (2 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_CCC_HVSlot 4 : RC_CCC_ROSlot 5 : EmptySlot 6 : EmptySlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
26/04/2006 51
RASMUX CCD CABLING SCHEME (20)
Exception 16: BOS1/BOS2 chambers (CCC connection)
BOS1A sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : SC_CCC_HV_BOS2Slot 8 : SC_CCC_RO_BOS2
BOS1C sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : SC_CCC_HV_BOS2Slot 8 : SC_CCC_RO_BOS2
BOS2A sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BOS2C sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
26/04/2006 52
RASMUX CCD CABLING SCHEME (21)
Exception 17: BOS5/BOS6 chambers (CCC connection)
BOS5A sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BOS5C sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
BOS6A sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : SC_CCC_HV_BOS5Slot 4 : SC_CCC_RO_BOS5Slot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BOS6C sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : SC_CCC_HV_BOS5Slot 6 : SC_CCC_RO_BOS5Slot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
26/04/2006 53
RASMUX CCD CABLING SCHEME (22)
Exception 18: BOG0 sectors 12 and 14 (2 chambers) CCC connections on BOF1: 2 Rasmux used
BOG0 Rasmux ASlot 1 : RC_INP_HV2 Slot 2 : RC_INP_HV3Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : EmptySlot 6 : EmptySlot 7 : SC_CCC_HV-BOF1ASlot 8 : SC_CCC_RO-BOF1A
BOG0 Rasmux CSlot 1 : RC_INP_HV1Slot 2 : RC_INP_HV4Slot 3 : Empty Slot 4 : Empty Slot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : SC_CCC_HV-BOF1CSlot 8 : SC_CCC_RO-BOF1C
26/04/2006 54
RASMUX CCD CABLING SCHEME (23)
Exception 19: BOG2/4 sectors 12 and 14 (8 chambers) , 8 inplanes: 2 Rasmux used
BOG2/4/6 A Rasmux 1Slot 1 : RC_INP_HV2 Slot 2 : RC_INP_HV3Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BOG2/4A Rasmux 2Slot 1 : RC_INP_HV1 Slot 2 : RC_INP_HV4Slot 3 : EmptySlot 4 : EmptySlot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : Empty
BOG2/4/6 C Rasmux 1Slot 1 : RC_INP_HV2 Slot 2 : RC_INP_HV3Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
BOG2/4 C Rasmux 2Slot 1 : RC_INP_HV1 Slot 2 : RC_INP_HV4Slot 3 : EmptySlot 4 : EmptySlot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : Empty
26/04/2006 55
RASMUX CCD CABLING SCHEME (24)
Exception 20: BOG6 (2 Rasmux) and BOG8 chambers (8 inplanes + CCC BOF7) : 8 chambers
BOG8A12 and BOG8A14 Slot 1 : RC_INP_RO2 Slot 2 : RC_INP_RO3Slot 3 : RC_INP_RO1Slot 4 : RC_INP_RO4Slot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BOG8C12 and BOG8C14 Slot 1 : RC_INP_RO2 Slot 2 : RC_INP_RO3Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_INP_RO1Slot 6 : RC_INP_RO4Slot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
BOG6A12 and BOG6A14 Rasmux 2 Slot 1 : RC_INP_HV1 Slot 2 : RC_INP_HV4Slot 3 : SC_CCC_HV_BOF7Slot 4 : SC_CCC_RO_BOF7Slot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : Empty
BOG6 C12 and BOG6C14 Rasmux 2Slot 1 : RC_INP_HV1 Slot 2 : RC_INP_HV4Slot 3 : SC_CCC_HV_BOF7Slot 4 : SC_CCC_RO_BOF7Slot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : Empty
26/04/2006 56
RASMUX CCD CABLING SCHEME (25)
Exception 21: BOL1/BOL2 chambers (Projective connection)
BOL1A: sector 1,3,5,7,9,11,13,15 (8 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRO_HV_BOL1Slot 6 : RC_PRO_RO_BOL1Slot 7 : RC_PRO_HV_BOL2Slot 8 : RC_PRO_RO_BOL2
BOL1C: sector 1,3,5,7,9,11,13,15 ( 8 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRO_HV_BOL1Slot 4 : RC_PRO_RO_BOL1Slot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_PRO_HV_BOL2Slot 8 : RC_PRO_RO_BOL2
BOL2A:sector 1,3,5,7,9,11,13,15 (8 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BOL2C:sector 1,3,5,7,9,11,13,15 (8 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
26/04/2006 57
RASMUX CCD CABLING SCHEME (26)
Exception 22: BOL3 and BOL4 sector 13 chambers (Projective connection) 1 Rasmux used
BOL3A13 (1 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO
BOL3C13 (1 chamber)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
Aluminium Plate BOLE-A13Slot 1 : RC_PRA_AHVSlot 2 : RC_PRA_AROSlot 3 : RC_PRA_CHV Slot 4 : RC_PRA_CRO Slot 5 : RC_PRO_HV_BOL3Slot 6 : RC_PRO_RO_BOL3 Slot 7 : RC_PRO_HV_BOL4Slot 8 : RC_PRO_RO_BOL4
Aluminium Plate C13Slot 1 : RC_PRA_AHVSlot 2 : RC_PRA_AROSlot 3 : RC_PRA_CHV Slot 4 : RC_PRA_CRO Slot 5 : RC_PRO_HV_BOL3Slot 6 : RC_PRO_RO_BOL3 Slot 7 : RC_PRO_HV_BOL4Slot 8 : RC_PRO_RO_BOL4
BOL4A13 (1 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO
BOL4C13 (1 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
26/04/2006 58
RASMUX CCD CABLING SCHEME (27)
Exception 23: BOL4 chambers (Projective connection) 2 Rasmux used
BOL4A sector 1,3,5,7,9,11,15: second RasmuxSlot 1 : RC_PRO_HVSlot 2 : RC_PRO_ROSlot 3 : Empty Slot 4 : Empty Slot 5 : EmptySlot 6 : Empty Slot 7 : EmptySlot 8 : Empty
BOL4C sector 1,3,5,7,9,11,15: second RasmuxSlot 1 : RC_PRO_HVSlot 2 : RC_PRO_ROSlot 3 : Empty Slot 4 : Empty Slot 5 : EmptySlot 6 : Empty Slot 7 : EmptySlot 8 : Empty
BOL4A: 1,3,5,7,9,11,15 (7 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO
BOL4C: 1,3,5,7,9,11,15 (7 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
26/04/2006 59
RASMUX CCD CABLING SCHEME (28)
Exception 24: BOL6 chambers (Projective)
BOL6A: sector 1,3,5,7,9,13 (6 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRO_HVSlot 4 : RC_PRO_ROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BOL6C: sector 1,3,5,7,9,13 (6 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRO_HVSlot 6 : RC_PRO_ROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
26/04/2006 60
RASMUX CCD CABLING SCHEME (29)
Exception 25: BOL6 chambers (Projective connection)
BOL6A11 (1 chamber)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRO_HVSlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BOL6C11 (1 chamber)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRO_HVSlot 6 : EmptySlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
BOL6A15 (1 chamber)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : EmptySlot 4 : RC_PRO_ROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO
BOL6C15 (1 chamber)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : EmptySlot 6: RC_PRO_ROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO
26/04/2006 61
RASMUX CABLING SCHEME (Ref plates)
AAA
SA
CL
ED
SC_PLC_RI
SC_PLC_LE
SC_PLR_RI
SC_PLR_LE
SC_BIL_RI
SC_BIL_LE
SC_BML_RI
SC_BML_LE
SA
CA
M
1
24
3
B
5
68
7
B
9
1012
11
B
13
1416
15
8 7 6 5 4 3 2 18 7 6 5 4 3 2 1
SL_PLC_RI
SL_PLC_LE
SL_PLR_RI
SL_PLR_LE
26/04/2006 62
APPENDIX: Exceptions to the previous rules
Due to the late decision on switching to labels starting at 1, for BIS, BIL,BIM,BIR and BML, the in_plane Rasled will be labeled from 0 to 3 (RL_INP_HV0-3) and the in_plane Rascam from 0 to 1 (RC_INP_RO0-1).