61
26/04/2006 1 LABELING OF BARREL ALIGNMENT CABLES •Inplane system cables •Praxial and Axial cables •Projective system cables •Reference system cables •Chamber to Chamber Connection (CCC) cables •BIR-BIM cables •RASMUX cabling scheme Appendix: Exceptions to the previous rules

LABELING OF BARREL ALIGNMENT CABLES

Embed Size (px)

DESCRIPTION

LABELING OF BARREL ALIGNMENT CABLES. Inplane system cables Praxial and Axial cables Projective system cables Reference system cables Chamber to Chamber Connection (CCC) cables BIR-BIM cables RASMUX cabling scheme Appendix: Exceptions to the previous rules. . RASCAM Lens RASLED. z. - PowerPoint PPT Presentation

Citation preview

Page 1: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 1

LABELING OF BARREL ALIGNMENT CABLES

•Inplane system cables•Praxial and Axial cables•Projective system cables•Reference system cables•Chamber to Chamber Connection (CCC) cables•BIR-BIM cables•RASMUX cabling scheme

•Appendix: Exceptions to the previous rules

Page 2: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 2

HV side

BIL6BIL5BIL4BIL3

RO side

BIL1 BIL2

The various systems on a chamber (1)

RASCAMLensRASLED

Ex: BIL Standard sectors (side A)

projective Reference systemprojective

BIL-BISConnection(CCC)

B-sensor platforms

Chambers are seen from the interaction point.

z

BIL-BISConnection(CCC)

praxial axial

Page 3: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 3

Reference system SACLED

Projective system RASLED (ray 2,3,4)

BIL

BIS

CCC SACLED

Projective system RASLED (ray 1)

Praxial proximityAxial

B-sensor

B-sensor

The various systems on a chamber (2)

Ex: BIL-BIS Standard sectors (side A)

CCC SCAM

Page 4: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 4

Naming conventions

The <cable type> are: RL : Rasnik Led RC : Rasnik CCD SL : SacLed SC : Scam CCDThe <sensor types> are: INP : Inplane PRA : Praxial AXI : Axial PRO : Projective REF : Reference CCC : Chamber to chamber connection BRM : BIR-BIM connectionFor the <location type> the following abbreviations are mixed together:

A : for A side C : for C side RO : readout side HV : high voltage side

1,2,3,4: when no other location can be indicatedThe <option> is the chamber_name: when a cable comes from another chamber

The cable name, consists of 3 (or 4) parts: <cable type>_<sensor type>_<location type>_<option>

Remark: SacLed and Scam CCD are used for Reference and CCC connection

Page 5: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 5

Inplane cables η=0

MDT

21

MDT

2

Remark: Normally the RASLED are on the HV side and the RASCAM on the RO side

HV side

RO side

A sideC side

4 3 2 1

1

1 2 3 4

RC_INP_RO2 (RasCam 2)

RC_INP_RO1 (RasCam 1)RC_INP_RO1 (RasCam1)

RC_INP_RO2 (RasCam 2)

RL_INP_HV4 (RasLed 4)

RL_INP_HV3 (RasLed 3)

RL_INP_HV2 (RasLed 2)

RL_INP_HV1 (RasLed 1)

RL_INP_HV4 (RasLed 4)

RL_INP_HV3 (RasLed 3)

RL_INP_HV2 (RasLed 2)

RL_INP_HV1 (RasLed 1)

Page 6: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 6

Inplane cables BOG

Remark: the RASLED are on the RO side and the RASCAM on the HV side

HV side

RO side

A sideC side

RC_INP_HV2 (RasCam 1)

RC_INP_HV1 (RasCam 2)RC_INP_HV1 (RasCam3)

RC_INP_HV2 (RasCam 4)

RL_INP_RO4 (RasLed 8)

RL_INP_RO3 (RasLed 7)

RL_INP_RO2 (RasLed 6)

RL_INP_RO1 (RasLed 5)

RL_INP_RO4 (RasLed 1)

RL_INP_RO3 (RasLed 2)

RL_INP_RO2 (RasLed 3)

RL_INP_RO1 (RasLed 4)

MDT

Page 7: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 7

Praxial labels

η

RL_PRA_CHV (RasLed, CHV corner)RC_PRA_CHV (RasCam, CHV corner)

HV side

RO side

RL_PRA_CRO (RasLed, CRO corner)RC_PRA_CRO (RasCam, CRO corner)

RL_PRA_AHV (RasLed, AHV corner)RC_PRA_AHV (RasCam, AHV corner)

RL_PRA_ARO (RasLed, ARO corner)RC_PRA_ARO (RasCam, ARO corner)

MDT A sideC side

Page 8: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 8

Axial labels

MDT ηA sideC side

RL_AXI_CHV (RasLed, CHV corner)RC_AXI_CHV (RasCam, CHV corner)

RL_AXI_AHV (RasLed, AHV corner)RC_AXI_AHV (RasCam, AHV corner)

RL_AXI_ARO (RasLed, ARO corner)RC_AXI_ARO (RasCam, ARO corner)

RL_AXI_CRO (RasLed, CRO corner)RC_AXI_CRO (RasCam, CRO corner)

Remark: Not all the labels indicated here, have to be present on the chamber !

RO side

HV side

Page 9: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 9

Projective labels

BIL BOL

RL_PRO_HV (RasLed, HV side)

RC_PRO_RO (RasCam, RO side)RL_PRO_RO (RasLed, RO side)

RC_PRO_HV (RasCam, HV side)

RO side

HV side

Page 10: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 10

Reference labels (MDT)

MDT

SL_REF_HV (SacLed, HV side)

SL_REF_RO (SacLed, RO side)

HV side

RO side

Page 11: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 11

Reference labels (plates on toroid ribs)

SC_BML_RI (SCam to BML)

SC_BIL_RI (SCAm to BIL)SC_BIL_LE (SCAm to BIL)

SC_BML_LE (SCam to BML)

Right sideLeft side

CCD labels:

SC_PLC_LE (SCam to next coil) SC_PLC_RI (SCam to next coil)

SC_PLR_RI (SCam to next rib)SC_PLR_LE (SCAm to next rib)

Page 12: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 12

Reference labels (plates on toroid ribs)

Right sideLeft side

Led labels:

SL_PLC_LE (SacLed to next coil) SL_PLC_RI (SacLed to next coil)

SL_PLR_RI (SacLed to next rib)SL_PLR_LE (SacLed to next rib)

Page 13: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 13

CCC labels

MDT

MDT

HV side

SL_CCC_HV (SacLed, HV side)

SL_CCC_RO (SacLed, RO side)

SC_CCC_HV (SCam, HV side)

SC_CCC_RO (SCam, RO side)

RO side

HV side

Page 14: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 14

BIR-BIM labels (sector 11)

BIR

BIMBIM

η=0

A sideC side

HV side

RO side

4 3 2 1 1 2 3 4

RC_BRM_HV (RasCam)RC_BRM_HV (RasCam)

z

RL_BRM_RO1

RL_BRM_RO2

RL_BRM_RO3

RL_BRM_RO4

RL_BRM_RO1

RL_BRM_RO2

RL_BRM_RO3

RL_BRM_RO4

BIRBIR BIR

Page 15: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 15

BIR-BIM labels (sector 15)

z

η=0

A sideC side

HV side

RO side

4 3 2 1 1 2 3 4

RC_BRM_HV (RasCam)RC_BRM_HV (RasCam)

BIM

BIR

BIM

RL_BRM_RO4

RL_BRM_RO1

RL_BRM_RO2

RL_BRM_RO3

RL_BRM_RO4

RL_BRM_RO1

RL_BRM_RO2

RL_BRM_RO3

z

BIR BIRBIR

Page 16: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 16

Special labels (<option>)The following cables need an <option> extension:

SC_CCC_HV => SC_CCC_HV_BIS2 for BIS2A08 and BIS2C08SC_CCC_RO => SC_CCC_RO_BIS2 for BIS2A08 and BIS2C08

SC_CCC_HV => SC_CCC_HV_BOS2 for BOS2A and BOS2C, sector 2,4,6,8,10,16SC_CCC_RO => SC_CCC_RO_BOS2 for BOS2A and BOS2C, sector 2,4,6,8,10,16

SC_CCC_HV => SC_CCC_HV_BOS5 for BOS5A and BOS5C, sector 2,4,6,8,10,16SC_CCC_RO => SC_CCC_RO_BOS5 for BOS5A and BOS5C, sector 2,4,6,8,10,16

SC_CCC_HV => SC_CCC_HV_BOF7 for BOF7A and BOF7C, sector 12,14SC_CCC_RO => SC_CCC_RO_BOF7 for BOF7A and BOF7C, sector 12,14

RC_PRO_HV => RC_PRO_HV_BOL2 for BOL2A and BOL2C, sector 1,3,5,7,9,11,15RC_PRO_RO => RC_PRO_RO_BOL2 for BOL2C and BOL2C, sector 1,3,5,7,9,11,15

Page 17: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 17

RASMUX CABLING SCHEME (Chambers)

RL_INP_HV1

RL_INP_HV3

RL_INP_HV2

RL_INP_HV4

A

RL_ PRA_AHV

RL_ PRA_CHV

RL_ PRA_ARO

RL_ PRA_CRO

A

RL_ AXI_XHV

RL_ PRO_HV

RL_ AXI_XRO

RL_ PRO_RO

A

SL_REF_HV

SL_ CCC_HV

SL_ REF_RO

SL_ CCC_RO

RA

S(S

AC

)LE

D

RC_INP_RO1

RC_INP_RO2

RC_ PRA_AHV

RC_ PRA_ARO

RC_ PRA_CHV

RC_ PRA_CRO

RC_AXI_XHV

RC_ AXI_XRO

RA

S(S

)CA

M

Remark: standard MDT with NO Projective, CCC or BIR-BIM CCD

1

24

3

B

5

68

7

B

9

1012

11

B

13

1416

15

8 7 6 5 4 3 2 18 7 6 5 4 3 2 1

Page 18: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 19

RASMUX LED CABLING SCHEME (2)

Inplane

Praxial

Axial

Projective

BIL1-2

CCC

Exception 1: BIL2 sector 9 (BIL1-BIL2 connection), 2 chambers

Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : RL_PRA_AHV or emptySlot 6 : RL_PRA_ARO or emptySlot 7 : RL_PRA_CHV or emptySlot 8 : RL_PRA_CRO or emptySlot 9 : RL_AXI_AHV or RL_AXI_CHVSlot 10: RL_AXI_ARO or RL_AXI_CROSlot 11: RL_PRO_HVSlot 12: RL_PRO_ROSlot 13: SL_CCI_HVSlot 14: SL_CCI_ROSlot 15: SL_CCC_HVSlot 16: SL_CCC_RO

Page 19: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 20

RASMUX LED CABLING SCHEME (3)

Exception 2: BIM1 (BIR-BIM connection)

BIM1 sector 11 and 15 (4 chambers)Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : RL_PRA_AHV or emptySlot 6 : RL_PRA_ARO or emptySlot 7 : RL_PRA_CHV or emptySlot 8 : RL_PRA_CRO or emptySlot 9 : RL_AXI_AHV or RL_AXI_CHVSlot 10: RL_AXI_ARO or RL_AXI_CROSlot 11: RL_BRM_RO1Slot 12: RL_BRM_RO3Slot 13: RL_BRM_RO2Slot 14: RL_BRM_RO4Slot 15: SL_CCC_HV or emptySlot 16: SL_CCC_RO or empty

Inplane

Praxial

Axial

BIR/BIM

BIR/BIM

CCC

Page 20: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 21

RASMUX LED CABLING SCHEME (4)

Exception 3: BIM4 (BIR-BIM connection)

BIM4 sector 11, 15 (4 chambers):Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : RL_PRA_AHVSlot 6 : RL_PRA_AROSlot 7 : RL_PRA_CHVSlot 8 : RL_PRA_CROSlot 9 : RL_AXI_AHV or RL_AXI_CHVSlot 10: RL_AXI_ARO or RL_AXI_CROSlot 11: RL_PRO_HV or emptySlot 12: RL_PRO_RO or emptySlot 13: RL_BRM_RO1Slot 14: EmptySlot 15: RL_BRM_RO2 Slot 16: Empty

Inplane

Praxial

Axial

Projective

Page 21: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 22

RASMUX LED CABLING SCHEME (5)

Inplane

Praxial

Axial

CCC

Exception 4: BIM5 (BIR-BIM connection)

BIM5 sector 11 (2 chambers):Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : RL_PRA_AHVSlot 6 : RL_PRA_AROSlot 7 : RL_PRA_CHVSlot 8 : RL_PRA_CROSlot 9 : RL_AXI_AHV or RL_AXI_CHVSlot 10: RL_AXI_ARO or RL_AXI_CROSlot 11: RL_PRO_HVSlot 12: RL_BRM_RO3Slot 13: RL_REF_HV Slot 14: RL_BRM_RO4 Slot 15: SL_CCC_HVSlot 16: Empty

ProjectiveBIR-BIMReferenceBIR-BIM

Page 22: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 23

RASMUX LED CABLING SCHEME (6)

Inplane

Praxial

Axial

CCC

Exception 5: BIM5 (BIR-BIM)

BIM5 sector 15 (2 chambers):Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : RL_PRA_AHV or emptySlot 6 : RL_PRA_ARO or emptySlot 7 : RL_PRA_CHV or emptySlot 8 : RL_PRA_CRO or emptySlot 9 : RL_AXI_AHV or RL_AXI_CHVSlot 10: RL_AXI_ARO or RL_AXI_CROSlot 11: RL_BRM_RO3Slot 12: RL_PRO_ROSlot 13: RL_BRM_RO4 Slot 14: RL_REF_RO Slot 15: EmptySlot 16: SL_CCC_RO

BIR-BIMProjectiveBIR-BIMReference

Page 23: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 24

RASMUX LED CABLING SCHEME (7)Exception 6: BMF1A (no praxials), BMF2A (4 Axials), BMF3A, sectors 12,14

BMF1A (2 chambers):Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : EmptySlot 9 : RL_AXI_CHVSlot 10: RL_AXI_CROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty

BMF2A (2 chambers):Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : RL_AXI_AHVSlot 6 : RL_AXI_AROSlot 7 : EmptySlot 8 : EmptySlot 9 : RL_AXI_CHVSlot 10: RL_AXI_CROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty

BMF3A (2 chambers):Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : EmptySlot 9 : RL_AXI_AHVSlot 10: RL_AXI_AROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty

Page 24: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 25

RASMUX LED CABLING SCHEME (8)Exception 6: BMF1C (no praxials), BMF2C (4 Axials), BMF3C, sectors 12,14

BMF1C (2 chambers):Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : EmptySlot 9 : RL_AXI_AHVSlot 10: RL_AXI_AROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty

BMF2C (2 chambers):Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : RL_AXI_CHVSlot 6 : RL_AXI_CROSlot 7 : EmptySlot 8 : EmptySlot 9 : RL_AXI_AHVSlot 10: RL_AXI_AROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty

BMF3C (2 chambers):Slot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV2Slot 3 : RL_INP_HV3Slot 4 : RL_INP_HV4Slot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : EmptySlot 9 : RL_AXI_CHVSlot 10: RL_AXI_CROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty

Page 25: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 26

RASMUX LED CABLING SCHEME (9)Exception 7: BML4, sectors 13 = 2 Aluminium Frames for the elevator

BML4A (1 alu frame)Slot 1 : EmptySlot 2 : EmptySlot 3 : EmptySlot 4 : EmptySlot 5 : RL_PRA_AHVSlot 6 : RL_PRA_AROSlot 7 : RL_PRA_CHVSlot 8 : RL_PRA_CROSlot 9 : RL_AXI_CHVSlot 10: RL_AXI_CROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty

BML4C (1 alu frame)Slot 1 : EmptySlot 2 : EmptySlot 3 : EmptySlot 4 : EmptySlot 5 : RL_PRA_AHVSlot 6 : RL_PRA_AROSlot 7 : RL_PRA_CHVSlot 8 : RL_PRA_CROSlot 9 : RL_AXI_AHVSlot 10: RL_AXI_AROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty

Page 26: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 27

RASMUX LED CABLING SCHEME (10)Exception 8: BOLE, sectors 13 = 2 Aluminium Frames for the elevator

BOLE (2 alu frames)Slot 1 : EmptySlot 2 : EmptySlot 3 : EmptySlot 4 : EmptySlot 5 : RL_PRA_AHVSlot 6 : RL_PRA_AROSlot 7 : RL_PRA_CHVSlot 8 : RL_PRA_CROSlot 9 : EmptySlot 10: EmptySlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty

Page 27: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 28

RASMUX LED CABLING SCHEME (11)Exception 9: BOG0, sectors 12 and 14 (2 chambers), 8 inplanes: 2 Rasmux used

BOG0 RasMux ASlot 1 : RL_INP_HV1 Slot 2 : RL_INP_HV4Slot 3 : RL_INP_HV5Slot 4 : RL_INP_HV8Slot 5 : RL_PRA_AHVSlot 6 : RL_PRA_AROSlot 7 : EmptySlot 8 : Empty Slot 9 : RL_AXI_CHVSlot 10: RL_AXI_CROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty

BOG0 RasMux CSlot 1 : RL_INP_HV2Slot 2 : RL_INP_HV3Slot 3 : RL_INP_HV6Slot 4 : RL_INP_HV7Slot 5 : EmptySlot 6 : EmptySlot 7 : RL_PRA_CHVSlot 8 : RL_PRA_CROSlot 9 : RL_AXI_AHVSlot 10: RL_AXI_AROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty

Page 28: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 29

RASMUX LED CABLING SCHEME (12)Exception 10: BOG2/4/6, sectors 12 and 14 (12 chambers), 8 inplanes: 2 Rasmux used

BOG2/4/6 A RasMux 1Slot 1 : RL_INP_RO1 Slot 2 : RL_INP_RO4Slot 3 : RL_INP_RO5Slot 4 : RL_INP_RO8Slot 5 : RL_PRA_AHVSlot 6 : RL_PRA_AROSlot 7 : RL_PRA_CHVSlot 8 : RL_PRA_CRO Slot 9 : RL_AXI_CHV Slot 10: RL_AXI_CROSlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty

BOG2/4/6 A RasMux 2Slot 1 : RL_INP_RO2 Slot 2 : RL_INP_RO3Slot 3 : RL_INP_RO6Slot 4 : RL_INP_RO7Slot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : Empty Slot 9 : Empty Slot 10: EmptySlot 11: EmptySlot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty

Page 29: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 30

RASMUX LED CABLING SCHEME (13)Exception 11: BOG8, sectors 12 and 14 (4 chambers), 8 inplanes

BOG8 RasMux Slot 1 : RL_INP_RO1 Slot 2 : RL_INP_RO4Slot 3 : RL_INP_RO5Slot 4 : RL_INP_RO8Slot 5 : RL_PRA_AHVSlot 6 : RL_PRA_AROSlot 7 : RL_PRA_CHVSlot 8 : RL_PRA_CRO Slot 9 : RL_AXI_CHV Slot 10: RL_AXI_CROSlot 11: RL_INP_RO2Slot 12: RL_INP_RO3Slot 13: RL_INP_RO6Slot 14: RL_INP_RO7Slot 15: EmptySlot 16: Empty

Page 30: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 31

RASMUX LED CABLING SCHEME (13)Exception 12: BOS6, all sectors

BOS6A RasMux Slot 1 : RL_INP_RO1 Slot 2 : EmptySlot 3 : RL_INP_RO4Slot 4 : EmptySlot 5 : EmptySlot 6 : EmptySlot 7 : RL_PRA_CHVSlot 8 : RL_PRA_CRO Slot 9 : RL_INP_RO2Slot 10: EmptySlot 11: RL_INP_RO3Slot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty

BOS6C RasMux Slot 1 : RL_INP_RO1 Slot 2 : EmptySlot 3 : RL_INP_RO4Slot 4 : EmptySlot 5 : RL_PRA_AHVSlot 6 : RL_PRA_AROSlot 7 : EmptySlot 8 : EmptySlot 9 : RL_INP_RO2Slot 10: EmptySlot 11: RL_INP_RO3Slot 12: EmptySlot 13: EmptySlot 14: EmptySlot 15: EmptySlot 16: Empty

Page 31: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 32

RASMUX CCD CABLING SCHEME (1)Default chamber:

Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHV or RC_AXI_CHVSlot 8 : RC_AXI_ARO or RC_AXI_CRO

The chamber which makes exception to this scheme are chamber with an Projective, CCC or Bir-Bim CCD cable (174 exceptions).

This are: Name Sector Amount 1.) BIS1 and BIS7 all sectors 32 2.) BIL1 sector 9 2 3.) BIR1 sector 11 and 15 4 4.) BIR2 sector 11 and 15 4 5.) BIR4 sector 11 and 15 4 6.) BIR5 sector 11 and 15 4 7.) BMS1 sector 2,4,6,8,10,16 12 8.) BMS4 sector 2,4,6,8,10,16 12 9.) BMS5 sector 2,4,6,8,10,16 12 10.) BMF1-BMF3 sector 12 and 14 12 11.) BOS1 sector 2,4,6,8,10,16 12 12.) BOS6 sector 2,4,6,8,10,16 12 13.) BOG0 sector 12 and 14 2 14.) BOG2/4 sector 12 and 14 8 15.) BOG6/8 sector 12 and 14 8 16.) BOL1 sector 1,3,5,7,9,11,15 14 17.) BOL3, BOL4 sector 13 4 18.) BOL4 sector 1,3,5,7,9,11,15 14 19.) BOL6 sector 1,3,5,7,9,13 12 20.) BOL6 sector 11,15 4

Page 32: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 33

RASMUX CCD CABLING SCHEME (2)

Rule for Projective, CCC, BIM/BIM CCD cables (see schemes here after):

a) In the above scheme fill the empty slots in the following order: 1. RC_PRO_HV 2. RC_PRO_RO 3. RC_CCC_HV 4. RC_CCC_RO 5. RC_BRM_HV 6. RC_BRM_HV

b) If all Rasmux CCD slots are occupied go to the neighboring MDT: BOS2=>BOS1, BOS5=>BOS6, BOL2=>BOL1, BOF7=>BOG8 or neighbouring alu-plate: BOL3A13, BOL4A13 => ALO3A13 BOL3C13, BOL4C13 =>ALO3C13 or use a second RASMUX, this is the case for BOL4, BOF1

Page 33: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 34

RASMUX CCD CABLING SCHEME (3)

BIS1 sector 2,4,6,12,14 (10 chambers):

Slot 1 : RC_INP_RO1 Slot 2 : EmptySlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : SC_CCC_HVSlot 8 : SC_CCC_RO

Exception 1: BIS1 (CCC connection)

Page 34: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 35

RASMUX CCD CABLING SCHEME (4)

Exception 2: BIS2A10 & BIS2C10 (CCC connection)

BIS1A10:Slot 1 : RC_INP_RO1 Slot 2 : EmptySlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : SC_CCC_RO_BIS2Slot 8 : Empty

BIS2A10:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BIS1C10:Slot 1 : RC_INP_RO1 Slot 2 : EmptySlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : SC_CCC_HV_BIS2Slot 8 : Empty

BIS2C10:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

Page 35: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 36

RASMUX CCD CABLING SCHEME (5)

Exception 3: BIS4 sector 2,4,6,8,10,16 (CCC connection)

BIS4A sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BIS4C sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

BIS3A sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_RO_BIS4Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_AHV

BIS3 sector 2,4,6,8,10,16 (6 chambers) :Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_RO_BIS4Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

Page 36: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 37

RASMUX CCD CABLING SCHEME (6)

BIS7A sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : EmptySlot 3 : SC_CCC_HVSlot 4 : SC_CCC_ROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BIS7C sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : EmptySlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : SC_CCC_HVSlot 6 : SC_CCC_ROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

Exception 4: BIS7 chambers (CCC connection)

Page 37: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 38

RASMUX CCD CABLING SCHEME (7)

BIS1A08:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : EmptySlot 8 : Empty

Exception 5: BIS A chambers with one CCC connection

BIS1A16:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : EmptySlot 8 : Empty

BIS2A08:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BIS2A16:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BIS4A12:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BIS3A12:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

Page 38: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 39

RASMUX CCD CABLING SCHEME (8)

Exception 5: BIS A chambers with one CCC connection

BIS7A14:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : EmptySlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BIS6A14:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BIS7A12:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : EmptySlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BIS6A12:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BIS4A14:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BIS3A14:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

Page 39: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 40

RASMUX CCD CABLING SCHEME (9)

BIS1C08:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : EmptySlot 8 : Empty

Exception 6: BIS C chambers with one CCC connection

BIS1C16:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : EmptySlot 8 : Empty

BIS2C08:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

BIS2C16:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

BIS4C12:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

BIS3C12:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

Page 40: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 41

RASMUX CCD CABLING SCHEME (10)

Exception 6: BIS C chambers with one CCC connection

BIS7C14:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : EmptySlot 6 : EmptySlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

BIS6C14:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

BIS7C12:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : EmptySlot 6 : EmptySlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

BIS6C12:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

BIS4C14:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_HVSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

BIS3C14:Slot 1 : RC_INP_RO1 Slot 2 : SC_CCC_ROSlot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

Page 41: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 42

RASMUX CCD CABLING SCHEME (11)

Exception 7: BIL1 chambers (no praxial, CCC BIL1-BIL2 connection)

BIL1A09 (1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : EmptySlot 4 : EmptySlot 5 : EmptySlot 6 : EmptySlot 7 : SC_CCC_HVSlot 8 : SC_CCC_RO

BIL1C09 (1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : EmptySlot 4 : EmptySlot 5 : EmptySlot 6 : EmptySlot 7 : SC_CCC_HVSlot 8 : SC_CCC_RO

Page 42: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 43

RASMUX CCD CABLING SCHEME (12)

Exception 8: BIR1 chambers (BIR-BIM connection)

BIR1A011 and BIR1C11 (2 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_BRM_HVSlot 4 : EmptySlot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : Empty

BIR1A15 and BIR1C15 (2 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_BRM_HVSlot 4 : EmptySlot 5 : Empty Slot 6 : EmptySlot 7 : Empty Slot 8 : Empty

Page 43: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 44

RASMUX CCD CABLING SCHEME (13)

Exception 9: BIR2 chambers (BIR-BIM connection)

BIR2A11 (1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_BRM_HVSlot 6 : EmptySlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BIR2C11 (1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_BRM_HVSlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

BIR2A15 ( 1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_BRM_HVSlot 6 : EmptySlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BIR2C15 ( 1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_BRM_HVSlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

Page 44: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 45

RASMUX CCD CABLING SCHEME (14)

Exception 10: BIR4 chambers (BIR_BIM connection)

BIR4A11 ( 1 chamber) :Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_BRM_HVSlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BIR4C11 (1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_BRM_HVSlot 6 : EmptySlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

BIR4A15 ( 1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_BRM_HVSlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BIR4C15 ( 1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_BRM_HVSlot 6 : EmptySlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

Page 45: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 46

RASMUX CCD CABLING SCHEME (15)

Exception 11: BIR5 chambers (BIR-BIM connection)

BIR5A11 (1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_BRM_HVSlot 6 : Empty Slot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BIR5C11 (1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_BRM_HVSlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

BIR5A15 ( 1chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_BRM_HVSlot 6 : EmptySlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BIR5C15 (1 chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_BRM_HVSlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

Page 46: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 47

RASMUX CCD CABLING SCHEME (16)

Exception 12: BMS1 chambers (CCC connection)

BMS1 sector 2,4,6,10,16 (10 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : SC_CCC_HVSlot 8 : SC_CCC_RO

BMS1A08 ( 1chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : EmptySlot 7 : SC_CCC_HVSlot 8 : SC_CCC_RO

BMS1C08 ( 1chamber):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : SC_CCC_HVSlot 8 : SC_CCC_RO

Page 47: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 48

RASMUX CCD CABLING SCHEME (17)

Exception 13: BMS4 chambers (CCC connection)

BMS4A sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : SC_CCC_HVSlot 4 : SC_CCC_ROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BMS4C sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : SC_CCC_HVSlot 6 : SC_CCC_ROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

Page 48: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 49

RASMUX CCD CABLING SCHEME (18)

Exception 14: BMS5 chambers (CCC connection)

BMS5A sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : SC_CCC_HVSlot 6 : SC_CCC_ROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BMS5C sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : SC_CCC_HVSlot 4 : SC_CCC_ROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

Page 49: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 50

RASMUX CCD CABLING SCHEME (19)

Exception 15: BMF chambers (4 axials) , sectors 12 and 14

BMF1A, (2 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_CCC_HVSlot 4 : RC_CCC_ROSlot 5 : EmptySlot 6 : EmptySlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BMF2A, (2 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_AXI_CHVSlot 4 : RC_AXI_CROSlot 5 : RC_CCC_HVSlot 6 : RC_CCC_ROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BMF3A, (2 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_CCC_HVSlot 4 : RC_CCC_ROSlot 5 : EmptySlot 6 : EmptySlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

BMF1C, (2 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_CCC_HVSlot 4 : RC_CCC_ROSlot 5 : EmptySlot 6 : EmptySlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

BMF2C, (2 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_AXI_AHVSlot 4 : RC_AXI_AROSlot 5 : RC_CCC_HVSlot 6 : RC_CCC_ROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

BMF3C, (2 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_CCC_HVSlot 4 : RC_CCC_ROSlot 5 : EmptySlot 6 : EmptySlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

Page 50: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 51

RASMUX CCD CABLING SCHEME (20)

Exception 16: BOS1/BOS2 chambers (CCC connection)

BOS1A sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : SC_CCC_HV_BOS2Slot 8 : SC_CCC_RO_BOS2

BOS1C sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : SC_CCC_HV_BOS2Slot 8 : SC_CCC_RO_BOS2

BOS2A sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BOS2C sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

Page 51: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 52

RASMUX CCD CABLING SCHEME (21)

Exception 17: BOS5/BOS6 chambers (CCC connection)

BOS5A sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BOS5C sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

BOS6A sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : SC_CCC_HV_BOS5Slot 4 : SC_CCC_RO_BOS5Slot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BOS6C sector 2,4,6,8,10,16 (6 chambers):Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : SC_CCC_HV_BOS5Slot 6 : SC_CCC_RO_BOS5Slot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

Page 52: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 53

RASMUX CCD CABLING SCHEME (22)

Exception 18: BOG0 sectors 12 and 14 (2 chambers) CCC connections on BOF1: 2 Rasmux used

BOG0 Rasmux ASlot 1 : RC_INP_HV2 Slot 2 : RC_INP_HV3Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : EmptySlot 6 : EmptySlot 7 : SC_CCC_HV-BOF1ASlot 8 : SC_CCC_RO-BOF1A

BOG0 Rasmux CSlot 1 : RC_INP_HV1Slot 2 : RC_INP_HV4Slot 3 : Empty Slot 4 : Empty Slot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : SC_CCC_HV-BOF1CSlot 8 : SC_CCC_RO-BOF1C

Page 53: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 54

RASMUX CCD CABLING SCHEME (23)

Exception 19: BOG2/4 sectors 12 and 14 (8 chambers) , 8 inplanes: 2 Rasmux used

BOG2/4/6 A Rasmux 1Slot 1 : RC_INP_HV2 Slot 2 : RC_INP_HV3Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BOG2/4A Rasmux 2Slot 1 : RC_INP_HV1 Slot 2 : RC_INP_HV4Slot 3 : EmptySlot 4 : EmptySlot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : Empty

BOG2/4/6 C Rasmux 1Slot 1 : RC_INP_HV2 Slot 2 : RC_INP_HV3Slot 3 : RC_PRA_AHV Slot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

BOG2/4 C Rasmux 2Slot 1 : RC_INP_HV1 Slot 2 : RC_INP_HV4Slot 3 : EmptySlot 4 : EmptySlot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : Empty

Page 54: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 55

RASMUX CCD CABLING SCHEME (24)

Exception 20: BOG6 (2 Rasmux) and BOG8 chambers (8 inplanes + CCC BOF7) : 8 chambers

BOG8A12 and BOG8A14 Slot 1 : RC_INP_RO2 Slot 2 : RC_INP_RO3Slot 3 : RC_INP_RO1Slot 4 : RC_INP_RO4Slot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BOG8C12 and BOG8C14 Slot 1 : RC_INP_RO2 Slot 2 : RC_INP_RO3Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_INP_RO1Slot 6 : RC_INP_RO4Slot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

BOG6A12 and BOG6A14 Rasmux 2 Slot 1 : RC_INP_HV1 Slot 2 : RC_INP_HV4Slot 3 : SC_CCC_HV_BOF7Slot 4 : SC_CCC_RO_BOF7Slot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : Empty

BOG6 C12 and BOG6C14 Rasmux 2Slot 1 : RC_INP_HV1 Slot 2 : RC_INP_HV4Slot 3 : SC_CCC_HV_BOF7Slot 4 : SC_CCC_RO_BOF7Slot 5 : EmptySlot 6 : EmptySlot 7 : EmptySlot 8 : Empty

Page 55: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 56

RASMUX CCD CABLING SCHEME (25)

Exception 21: BOL1/BOL2 chambers (Projective connection)

BOL1A: sector 1,3,5,7,9,11,13,15 (8 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRO_HV_BOL1Slot 6 : RC_PRO_RO_BOL1Slot 7 : RC_PRO_HV_BOL2Slot 8 : RC_PRO_RO_BOL2

BOL1C: sector 1,3,5,7,9,11,13,15 ( 8 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRO_HV_BOL1Slot 4 : RC_PRO_RO_BOL1Slot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_PRO_HV_BOL2Slot 8 : RC_PRO_RO_BOL2

BOL2A:sector 1,3,5,7,9,11,13,15 (8 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BOL2C:sector 1,3,5,7,9,11,13,15 (8 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

Page 56: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 57

RASMUX CCD CABLING SCHEME (26)

Exception 22: BOL3 and BOL4 sector 13 chambers (Projective connection) 1 Rasmux used

BOL3A13 (1 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO

BOL3C13 (1 chamber)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

Aluminium Plate BOLE-A13Slot 1 : RC_PRA_AHVSlot 2 : RC_PRA_AROSlot 3 : RC_PRA_CHV Slot 4 : RC_PRA_CRO Slot 5 : RC_PRO_HV_BOL3Slot 6 : RC_PRO_RO_BOL3 Slot 7 : RC_PRO_HV_BOL4Slot 8 : RC_PRO_RO_BOL4

Aluminium Plate C13Slot 1 : RC_PRA_AHVSlot 2 : RC_PRA_AROSlot 3 : RC_PRA_CHV Slot 4 : RC_PRA_CRO Slot 5 : RC_PRO_HV_BOL3Slot 6 : RC_PRO_RO_BOL3 Slot 7 : RC_PRO_HV_BOL4Slot 8 : RC_PRO_RO_BOL4

BOL4A13 (1 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO

BOL4C13 (1 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

Page 57: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 58

RASMUX CCD CABLING SCHEME (27)

Exception 23: BOL4 chambers (Projective connection) 2 Rasmux used

BOL4A sector 1,3,5,7,9,11,15: second RasmuxSlot 1 : RC_PRO_HVSlot 2 : RC_PRO_ROSlot 3 : Empty Slot 4 : Empty Slot 5 : EmptySlot 6 : Empty Slot 7 : EmptySlot 8 : Empty

BOL4C sector 1,3,5,7,9,11,15: second RasmuxSlot 1 : RC_PRO_HVSlot 2 : RC_PRO_ROSlot 3 : Empty Slot 4 : Empty Slot 5 : EmptySlot 6 : Empty Slot 7 : EmptySlot 8 : Empty

BOL4A: 1,3,5,7,9,11,15 (7 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHV Slot 8 : RC_AXI_ARO

BOL4C: 1,3,5,7,9,11,15 (7 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

Page 58: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 59

RASMUX CCD CABLING SCHEME (28)

Exception 24: BOL6 chambers (Projective)

BOL6A: sector 1,3,5,7,9,13 (6 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRO_HVSlot 4 : RC_PRO_ROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BOL6C: sector 1,3,5,7,9,13 (6 chambers)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRO_HVSlot 6 : RC_PRO_ROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

Page 59: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 60

RASMUX CCD CABLING SCHEME (29)

Exception 25: BOL6 chambers (Projective connection)

BOL6A11 (1 chamber)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRO_HVSlot 4 : EmptySlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BOL6C11 (1 chamber)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : RC_PRO_HVSlot 6 : EmptySlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

BOL6A15 (1 chamber)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : EmptySlot 4 : RC_PRO_ROSlot 5 : RC_PRA_CHVSlot 6 : RC_PRA_CROSlot 7 : RC_AXI_AHVSlot 8 : RC_AXI_ARO

BOL6C15 (1 chamber)Slot 1 : RC_INP_RO1 Slot 2 : RC_INP_RO2Slot 3 : RC_PRA_AHVSlot 4 : RC_PRA_AROSlot 5 : EmptySlot 6: RC_PRO_ROSlot 7 : RC_AXI_CHVSlot 8 : RC_AXI_CRO

Page 60: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 61

RASMUX CABLING SCHEME (Ref plates)

AAA

SA

CL

ED

SC_PLC_RI

SC_PLC_LE

SC_PLR_RI

SC_PLR_LE

SC_BIL_RI

SC_BIL_LE

SC_BML_RI

SC_BML_LE

SA

CA

M

1

24

3

B

5

68

7

B

9

1012

11

B

13

1416

15

8 7 6 5 4 3 2 18 7 6 5 4 3 2 1

SL_PLC_RI

SL_PLC_LE

SL_PLR_RI

SL_PLR_LE

Page 61: LABELING OF BARREL ALIGNMENT CABLES

26/04/2006 62

APPENDIX: Exceptions to the previous rules

Due to the late decision on switching to labels starting at 1, for BIS, BIL,BIM,BIR and BML, the in_plane Rasled will be labeled from 0 to 3 (RL_INP_HV0-3) and the in_plane Rascam from 0 to 1 (RC_INP_RO0-1).